R+D department Altamira II error codes
00. Series and/or phases sequence power supply failure. 01. Stuck contactors detected with the lift stopped. 02. Security series opened with the lift stopped. Start sequence. 03. Security series opened while the lift is moving. Start sequence. 04. Security series opened with the lift stopped. 05. Security series opened while the lift is moving. 06. Slowing limits activated at the same time. Start sequence. 07. Bottom slowing limit activated when the lift was moving in the up direction. 08. Top slowing limit activated when the lift was moving in the down direction. 09. Stop magnets reverse reading. 10. Door series with the lift stopped (doors do not open). 11. Door series with the lift stopped (door close attempts expired). 12. Motor protection activated. Contactors stuck (led VC on the AL1 board was OFF when timer expired). 13. Motor protection activated. Contactors not energized (led VC on the AL1 board was ON when timer expired). 14. Door series: cannot close with lift stopped. Start sequence. 15. Slowing limits activated at the same time. Inspection mode. 16. No valid IM2 board connected. 17. Photocell/Safety edge activated for a period longer than “Obstruction time”. 18. Photocell/Safety edge activated. Door close attempts expired. 19. ENCODER shaft positioning system: shaft learning procedure required. 20. When starting the DTF procedure, the up and down buttons were still being hold after F0 appeared on the AL1 board display. 21. Emergency relays monitoring. 22. UNAVAILABLE 23. Overheating. NOTE: this fault only appears on the main board’s fault history, not on the displays. 24. UNAVAILABLE 25. Warning. In a Residlift with the hold-to-run lift control system activated, the passenger has stopped holding the travel button Revision date : 26/05/2015
Revision : 1
Page 1 of 3
R+D department Altamira II error codes
26. Warning. In an HYDROADVANCE lift, the system has detected that there is a technician in the pit 42. Pawl device B has not folded completely. 43. Pawl device A has not folded completely. 44. Pawl device B has not unfolded completely. 45. Pawl device A has not unfolded completely. 46. None of the pawl devices have folded completely. 47. None of the pawl devices have unfolded completely. 68. The DTF has not been able to correct the gliding distance when reading the stop magnet (error distance too big). NOTE: lift will reset itself after having this error. 69. CAN bus communication error between AL1 board and drive unit (the board has not received a CAN message). 70. Emergency stop in the drive unit. Main contactors energized but dropped automatically. 71. Security series opened (not doors) after the AL1 board sent the order to move but before the main contactors energized. 72. Security series opened (doors) after the AL1 board sent the order to move but before the main contactors energized. 73. Emergency stop in the drive unit while the lift was moving. NOTE: if the security series are recovered, the lift will move slowly to the closest door in order to reset. 74. A fault has happened in the drive unit. 75. Emergency stop in the drive unit while the lift was resetting (main contactors were energized). 76. A fault has happened in the drive unit while the lift was resetting (main contactors were OFF when the fault happened). 77. Slowing limit read out of position. 79. No DTF shaft learning procedure has been performed. It is necessary to do one. 82. Safety series opened before led LV (AL1 board). 83. Safety series opened before led VF (AL1 board). 84. Safety series opened before led SF (AL1 board). 85. Safety series opened before led SM (AL1 board). 86. Safety series opened before led EX (AL1 board). 87. Safety series opened before led PC (AL1 board).
Revision date : 26/05/2015
Revision : 1
Page 2 of 3
R+D department Altamira II error codes
88. Safety series opened before led SC (AL1 board).
FE.
Firemen mode activated.
OH.
Over heating (problem with motor PTC, control panel temperature, or lack of power supply for the car lights).
KG.
Over load (problem with the load weighing device, or pressure switch in hydraulic lifts).
Revision date : 26/05/2015
Revision : 1