37 1 1MB
C511-E016A
Printed in Japan 6295-09801-30A-NS
GENERAL RADIOGRAPHIC SYSTEM
Functions That Incorporate Wisdom and Tenderness Ensuring stress-free imaging by navigating radiography preparation
Navigating Radiography Preparation
The Arrival of a New "One-Touch Guide" EZy-Rad Pro, an X-ray radiography system that combines compact dimensions to allow installation in tight spaces and makes imaging possible with simple operations, has arrived. Its innovative "one-touch guide" informs the operator of the proper exposure distance and cassette size in addition to the X-ray conditions, and thereby facilitates stress-free preparation. It offers superior image quality and ease of use that meets the demands of medical facilities. This is Shimadzu's new standard for diagnostic X-ray imaging systems.
Optimum setting of the exposure conditions like the exposure distance, cassette size, and grid requirements in accordance with the region to be examined is extremely difficult and requires experience. With EZyRad Pro, the wisdom of experienced operators is incorporated in the console. The pre-programmed exposure conditions are displayed on the console for each region, enabling stress-free preparation even for unfamiliar regions. The Communication option enables automatic linking with the radiography program selected for CR (optional).
Confirmed with display CHEST X-ray conditions
35cm X 35cm cassette
Patient-Comfort Soft Table Top
SID 2m
X-ray conditions
One-touch guide Once APR is selected … X-ray conditions Exposure distance
43cm X 35cm cassette
Grid
SID 1m
ELBOW
Cassette size X-ray conditions
Grid requirements (cassette size display is selectable, cm / inch)
No Grid
SID 1m
Easy Operation NEW
The table surface is covered with a soft synthetic leather mattress to alleviate the hard, cold feeling that is experienced with standard tables. Naturally, it has antibacterial specifications. The heavy-duty wooden table top is selectable as well.
2
Grid
ABDOMEN
24cm X 30cm cassette
No Hardness, No Cold Feeling
NEW
User-Friendly Console
432 Easy-to-Set Anatomical Programs The ultra compact console is an example of Shimadzu’s leading-edge technology. It is designed to save space while enhancing operator-friendly interface. A standard feature is the productivity-boosting 432 anatomical programs. Entering and changing exposure parameters in these programs is straight-forward and easy. Additionally, automatic exposure control (AEC) and phototimer sensitivity selection are available as optional features.
3
Easy positioning via linked mechanism
Clear images provide high-quality diagnosis
The linkage of X-ray tube and cassette unit ensure the cassette tray is always centered on the X-ray beam center. This means no time-consuming focus-point positioning, and provides accurate, worryfree radiography. This linkage can also be easily released, allowing oblique radiography.
A design based on a 60kHz high-frequency, inverter, X-ray highvoltage generator and a 140kHU high-capacity X-ray tube unit allows high-current short-time radiography. This produces sharp images, regardless of patient movement.
Note: The cassette tray cannot move in the transverse axis direction.
High output
High current determines image quality
A-Pack, AH-Pack : 16kW 200mA
High mAs for all types of patients
MH-Pack, AH-Pack : 100mAs (200mAs optional)
Inverter provides a small capacity power source (1.5kVA) (AH-Pack & MH-Pack)
(A-Pack and AH-Pack)
New Functions Unique to EZy-Rad Pro That Reflect Consideration of Dose Management Assisting X-ray dose management Reference skin dose indicator
NEW
The exposure distance is measured with an ultrasonic distance meter attached to front of the collimator.
Accommodating a variety of locations, the EZy-Rad Pro AH-Pack and MH-Pack can be operated using only 1.5kVA power source. Neither special power contracts nor expensive transformer is needed.
Compact Size 24cm
With the generator tucked under the examination table and no requirement for wall or ceiling supports, the EZy-Rad Pro requires a floor area of only 2.7m × 1.8m as the minimum space.
OPTION
93cm
Example of minimum installation space
105cm 148cm 59cm (M-Pack and MH-Pack only)
2.7m
1.8m
* Lieder cassette stand is not included. Rails do not have to be fixed to walls. Units can be delivered through 70cm wide entrance.
Wide transverse coverage for orthopedic radiography (M-Pack and MH-Pack only) Smoothly perform radiography of arm and leg joints, thanks to an X-ray tube arm design that allows easy forward and backward positioning. X-ray focus points can be set near the patient, when hand or elbow joint radiography is performed from the front of the table, allowing the patient to enjoy a relaxed, natural posture. Easy positioning allows leg and foot joint radiography to be performed without requiring the patient to turn left or right.
The dose is calculated before exposure from the set conditions and exposure distance and is displayed in real time.
In response to the everincreasing demand for lower doses, we have prepared a function that calculates and displays the predicted X-ray dose before exposure based on NDD method (optional). Combining the reference skin dose indicator and Communication option makes it possible to notify the CR side of the actual exposure conditions and dose calculated after exposure.
Linking radiography program with Communication Option
NEW
After examination, the exposure conditions can be sent to the CR side. (Note) Some CR models may be not compatible with EZy-Rad Pro. Please contact Shimadzu sales representative office for more details. (M-Pack and MH-Pack only)
4
5
Specifications M-Pack
Units: mm (inch) Scale: 1/50
Dimensions (A-Pack and AH-Pack)
Specifications
Units: mm (inch) Scale: 1/50
X-ray high voltage generator
A-Pack
MH-Pack
X-ray high voltage generator Control method
High frequency Inverter (maximum 60kHz)
Rating
20kW
100kV 160mA [320mA] 80kV 200mA [400mA] 720 (28.3)
720 (28.3)
1025 (40.4)
240
16kW 125kV 125mA [250mA]
Tube voltage setting range 40 - 125kV Tube current setting range 80 - 250mA mAs setting range
High frequency Inverter (maximum 60 kHz)
Rating
100kV 200mA [400mA] 80kV 250mA [500mA] [ ]: Current converted into two-pulse generator
0.32 - 320mAs
AH-Pack
Control method
125kV 160mA [320mA]
0.32 - 100mAs (0.32 - 200mAs)*
[ ]: Current converted into two-pulse generator
1020 (40.4)
Dimensions (M-Pack and MH-Pack)
Tube voltage setting range
40 - 125kV
Tube current setting range
63 - 200mA
mAs setting range
0.5 - 320mAs
0.5 - 100mAs (0.5 - 200mAs)*
125kV 36mAs (71mAs)*
125kV 32mAs (63mAs)*
100kV 50mAs (100mAs)* 1868 (73.5)
100kV 40mAs (80mAs)*
1868 (73.5)
80kV 63mAs (125mAs)*
80kV 50mAs (100mAs)*
45kV 100mAs (200mAs)* Timer setting range
0.0025 - 4sec
40kV 100mAs (200mAs)*
0.0025 - 1.6 sec (0.0025 - 3.2sec)*
0.0025 - 5sec
Anatomical program exposure Max. 432 user-programmable parameters
Anatomical program exposure
Max. 432 user-programmable parameters
Display
LED display
Display
LED display
Self-diagnostic function
Error message indication on the LED display
Self-diagnostic function
Error message indication on the LED display
2000 (78.7)
Power source
2000 (78.7) 1050 (41.3)
Power source
1050 (41.3)
System / Frequency
Single Phase AC / 50Hz or 60Hz
Nominal supply voltage
200 / 220 / 230 / 240V
100 / 110 / 120 / 200 / 220 / 230 / 240V
Transformer capacity
25kVA
1.5kVA
1.2mm
Max. anode heat capacity
100 kJ (140kHU)
900 (35.4)
930 (36.6)
90°
Vertical travel (focus - floor distance) 550 (21.7)
820 (32.3)
550 (21.7)
Longitudinal travel (Along the guide rail) 1050mm (41.3”) Operation : Manual, Electromagnetic lock
Operation : Manual, Electromagnetic lock
(
1)
X-ray tube rotations on the horizontal axis ±90°Click stop by 90° Radiographic table
±90°Click stop by 90° 1868×720mm (73.5”×28.3”)
Table top material
wood or soft synthetic leather (selectable)
Table height
550mm (21.7”)
X-ray grid Size of loadable cassette
Cabinet
R=10 : 1, N=40 lines/cm, fo=100cm, spacer=Al 14”×17” to 61/2”×81/2” cm or inch to size cassette based on IEC standard 60406
520 (20.5)
*(
55 (2.2)
Control console 520 (20.5)
Size of table top
220 (8.7)
1.1kg
Ezy-RAD Pro MH-Pack
295kg
Control console
1.1kg
6
1) Lieder cassette stand is not included.
14”×17” to 61/2”×81/2”
) : With 200mAs unit
Standard equipment Radiographic system
1
1
High Voltage generator Control cabinet including the x-ray high voltage generator
1
Control console
1
1
Control console
1
X-ray tube unit
1
X-ray tube unit
1
Collimator
1
Collimator
1
High voltage cable
1
High voltage cable
1
Power source - Control cabinet Cable 10m
1
Power source - Control cabinet Cable 10m
1
Control cabinet - Control console Cable 12m
1
Control cabinet - Control console Cable 12m
1
Weight (Including the control cabinet and high voltage generator)
Optional items (M-Pack / MH-Pack) 200mAs unit (MH-Pack) Bucky unit UD-PC, Phototimer control Direct phototimer pickup
Optional items (A-Pack / AH-Pack) Ezy-RAD Pro A-Pack
240kg
Control console
1.1kg
Ezy-RAD Pro AH-Pack
265kg
Control console
1.1kg
200mAs unit (AH-Pack) Bucky unit UD-PC, Phototimer control Direct phototimer pickup
Hand switch
Hand switch
Communication option ( 2)
Communication option ( 2) Reference skin dose indicator
Reference skin dose indicator
(
R=10 : 1, N=40lines/cm, fo=100cm, spacer=Al
Size of loadable cassette
*(
430 (16.9)
430 (16.9)
Control console
550mm (21.7”)
X-ray grid
Control cabinet including the X-ray high voltage generator
(Including the control cabinet and high voltage generator) 270kg
wood or soft synthetic leather (selectable)
Table height
170 (6.7)
) : With 200mAs unit
High voltage generator
Weight
1868×720mm (73.5”×28.3”)
Table top material
cm or inch size cassette based on IEC standard 60406
Standard equipment Radiographic system
Size of table top
55 (2.2)
680 (26.8)
170 (6.7)
Vertical travel (focus - floor distance)
Longitudinal travel (Along the guide rail) 1050mm (41.3”)
Radiographic table
Ezy-RAD Pro M-Pack
100kJ (140kHU)
850 - 1750mm (33.4” - 68.9”)
X-ray tube rotation on the horizontal axis
680 (26.8)
1.2mm
Max. anode heat capacity
240mm
Control console
1.5kVA
Operation : Manual, Electromagnetic lock
Transverse travel (towards operator)
1)
220 (8.7)
Effective focus size
Focus movement
Operation : Manual, Electromagnetic lock
Cabinet
20kVA
X-ray tube support unit 820 - 1750mm (32.2” - 68.9”)
(
Transformer capacity X-ray tube unit
X-ray tube support unit Focus movement
Single Phase AC / 50Hz or 60Hz 100 / 110 / 120 / 200 / 220 / 230 / 240V 200 / 220 / 230 / 240V
850 (33.5)
90°
Effective focus size
90°
Nominal supply voltage
System / Frequency
X-ray tube unit
90°
0.0025 - 1.6sec (0.0025 - 3.2sec)*
Timer setting range
(
2) Some CR models may be not compatible with EZy-Rad Pro. Please contact Shimadzu sales representative office for more details.
( 1) Lieder cassette stand is not included.
(
2) Some CR models may be not compatible with EZy-Rad Pro. Please contact Shimadzu sales representative office for more details.