Ezy Rad Op [PDF]

  • 0 0 0
  • Gefällt Ihnen dieses papier und der download? Sie können Ihre eigene PDF-Datei in wenigen Minuten kostenlos online veröffentlichen! Anmelden
Datei wird geladen, bitte warten...
Zitiervorschau

C511-E016A

Printed in Japan 6295-09801-30A-NS

GENERAL RADIOGRAPHIC SYSTEM

Functions That Incorporate Wisdom and Tenderness Ensuring stress-free imaging by navigating radiography preparation

Navigating Radiography Preparation

The Arrival of a New "One-Touch Guide" EZy-Rad Pro, an X-ray radiography system that combines compact dimensions to allow installation in tight spaces and makes imaging possible with simple operations, has arrived. Its innovative "one-touch guide" informs the operator of the proper exposure distance and cassette size in addition to the X-ray conditions, and thereby facilitates stress-free preparation. It offers superior image quality and ease of use that meets the demands of medical facilities. This is Shimadzu's new standard for diagnostic X-ray imaging systems.

Optimum setting of the exposure conditions like the exposure distance, cassette size, and grid requirements in accordance with the region to be examined is extremely difficult and requires experience. With EZyRad Pro, the wisdom of experienced operators is incorporated in the console. The pre-programmed exposure conditions are displayed on the console for each region, enabling stress-free preparation even for unfamiliar regions. The Communication option enables automatic linking with the radiography program selected for CR (optional).

Confirmed with display CHEST X-ray conditions

35cm X 35cm cassette

Patient-Comfort Soft Table Top

SID 2m

X-ray conditions

One-touch guide Once APR is selected … X-ray conditions Exposure distance

43cm X 35cm cassette

Grid

SID 1m

ELBOW

Cassette size X-ray conditions

Grid requirements (cassette size display is selectable, cm / inch)

No Grid

SID 1m

Easy Operation NEW

The table surface is covered with a soft synthetic leather mattress to alleviate the hard, cold feeling that is experienced with standard tables. Naturally, it has antibacterial specifications. The heavy-duty wooden table top is selectable as well.

2

Grid

ABDOMEN

24cm X 30cm cassette

No Hardness, No Cold Feeling

NEW

User-Friendly Console

432 Easy-to-Set Anatomical Programs The ultra compact console is an example of Shimadzu’s leading-edge technology. It is designed to save space while enhancing operator-friendly interface. A standard feature is the productivity-boosting 432 anatomical programs. Entering and changing exposure parameters in these programs is straight-forward and easy. Additionally, automatic exposure control (AEC) and phototimer sensitivity selection are available as optional features.

3

Easy positioning via linked mechanism

Clear images provide high-quality diagnosis

The linkage of X-ray tube and cassette unit ensure the cassette tray is always centered on the X-ray beam center. This means no time-consuming focus-point positioning, and provides accurate, worryfree radiography. This linkage can also be easily released, allowing oblique radiography.

A design based on a 60kHz high-frequency, inverter, X-ray highvoltage generator and a 140kHU high-capacity X-ray tube unit allows high-current short-time radiography. This produces sharp images, regardless of patient movement.

Note: The cassette tray cannot move in the transverse axis direction.

High output

High current determines image quality

A-Pack, AH-Pack : 16kW 200mA

High mAs for all types of patients

MH-Pack, AH-Pack : 100mAs (200mAs optional)

Inverter provides a small capacity power source (1.5kVA) (AH-Pack & MH-Pack)

(A-Pack and AH-Pack)

New Functions Unique to EZy-Rad Pro That Reflect Consideration of Dose Management Assisting X-ray dose management Reference skin dose indicator

NEW

The exposure distance is measured with an ultrasonic distance meter attached to front of the collimator.

Accommodating a variety of locations, the EZy-Rad Pro AH-Pack and MH-Pack can be operated using only 1.5kVA power source. Neither special power contracts nor expensive transformer is needed.

Compact Size 24cm

With the generator tucked under the examination table and no requirement for wall or ceiling supports, the EZy-Rad Pro requires a floor area of only 2.7m × 1.8m as the minimum space.

OPTION

93cm

Example of minimum installation space

105cm 148cm 59cm (M-Pack and MH-Pack only)

2.7m

1.8m

* Lieder cassette stand is not included. Rails do not have to be fixed to walls. Units can be delivered through 70cm wide entrance.

Wide transverse coverage for orthopedic radiography (M-Pack and MH-Pack only) Smoothly perform radiography of arm and leg joints, thanks to an X-ray tube arm design that allows easy forward and backward positioning. X-ray focus points can be set near the patient, when hand or elbow joint radiography is performed from the front of the table, allowing the patient to enjoy a relaxed, natural posture. Easy positioning allows leg and foot joint radiography to be performed without requiring the patient to turn left or right.

The dose is calculated before exposure from the set conditions and exposure distance and is displayed in real time.

In response to the everincreasing demand for lower doses, we have prepared a function that calculates and displays the predicted X-ray dose before exposure based on NDD method (optional). Combining the reference skin dose indicator and Communication option makes it possible to notify the CR side of the actual exposure conditions and dose calculated after exposure.

Linking radiography program with Communication Option

NEW

After examination, the exposure conditions can be sent to the CR side. (Note) Some CR models may be not compatible with EZy-Rad Pro. Please contact Shimadzu sales representative office for more details. (M-Pack and MH-Pack only)

4

5

Specifications M-Pack

Units: mm (inch) Scale: 1/50

Dimensions (A-Pack and AH-Pack)

Specifications

Units: mm (inch) Scale: 1/50

X-ray high voltage generator

A-Pack

MH-Pack

X-ray high voltage generator Control method

High frequency Inverter (maximum 60kHz)

Rating

20kW

100kV 160mA [320mA] 80kV 200mA [400mA] 720 (28.3)

720 (28.3)

1025 (40.4)

240

16kW 125kV 125mA [250mA]

Tube voltage setting range 40 - 125kV Tube current setting range 80 - 250mA mAs setting range

High frequency Inverter (maximum 60 kHz)

Rating

100kV 200mA [400mA] 80kV 250mA [500mA] [ ]: Current converted into two-pulse generator

0.32 - 320mAs

AH-Pack

Control method

125kV 160mA [320mA]

0.32 - 100mAs (0.32 - 200mAs)*

[ ]: Current converted into two-pulse generator

1020 (40.4)

Dimensions (M-Pack and MH-Pack)

Tube voltage setting range

40 - 125kV

Tube current setting range

63 - 200mA

mAs setting range

0.5 - 320mAs

0.5 - 100mAs (0.5 - 200mAs)*

125kV 36mAs (71mAs)*

125kV 32mAs (63mAs)*

100kV 50mAs (100mAs)* 1868 (73.5)

100kV 40mAs (80mAs)*

1868 (73.5)

80kV 63mAs (125mAs)*

80kV 50mAs (100mAs)*

45kV 100mAs (200mAs)* Timer setting range

0.0025 - 4sec

40kV 100mAs (200mAs)*

0.0025 - 1.6 sec (0.0025 - 3.2sec)*

0.0025 - 5sec

Anatomical program exposure Max. 432 user-programmable parameters

Anatomical program exposure

Max. 432 user-programmable parameters

Display

LED display

Display

LED display

Self-diagnostic function

Error message indication on the LED display

Self-diagnostic function

Error message indication on the LED display

2000 (78.7)

Power source

2000 (78.7) 1050 (41.3)

Power source

1050 (41.3)

System / Frequency

         Single Phase AC / 50Hz or 60Hz

Nominal supply voltage

   200 / 220 / 230 / 240V

100 / 110 / 120 / 200 / 220 / 230 / 240V

Transformer capacity

      25kVA

     1.5kVA

1.2mm

Max. anode heat capacity

100 kJ (140kHU)

900 (35.4)

930 (36.6)

90°

Vertical travel (focus - floor distance) 550 (21.7)

820 (32.3)

550 (21.7)

Longitudinal travel (Along the guide rail) 1050mm (41.3”) Operation : Manual, Electromagnetic lock

Operation : Manual, Electromagnetic lock

(

1)

X-ray tube rotations on the horizontal axis ±90°Click stop by 90° Radiographic table

±90°Click stop by 90° 1868×720mm (73.5”×28.3”)

Table top material

wood or soft synthetic leather (selectable)

Table height

550mm (21.7”)

X-ray grid Size of loadable cassette

Cabinet

R=10 : 1, N=40 lines/cm, fo=100cm, spacer=Al 14”×17” to 61/2”×81/2” cm or inch to size cassette based on IEC standard 60406

520 (20.5)

*(

55 (2.2)

Control console 520 (20.5)

Size of table top

220 (8.7)

1.1kg

Ezy-RAD Pro MH-Pack

295kg

Control console

1.1kg

6

1) Lieder cassette stand is not included.

14”×17” to 61/2”×81/2”

) : With 200mAs unit

Standard equipment Radiographic system

1

1

High Voltage generator Control cabinet including the x-ray high voltage generator

1

Control console

1

1

Control console

1

X-ray tube unit

1

X-ray tube unit

1

Collimator

1

Collimator

1

High voltage cable

1

High voltage cable

1

Power source - Control cabinet Cable 10m

1

Power source - Control cabinet Cable 10m

1

Control cabinet - Control console Cable 12m

1

Control cabinet - Control console Cable 12m

1

Weight (Including the control cabinet and high voltage generator)

Optional items (M-Pack / MH-Pack) 200mAs unit (MH-Pack) Bucky unit UD-PC, Phototimer control Direct phototimer pickup

Optional items (A-Pack / AH-Pack) Ezy-RAD Pro A-Pack

240kg

Control console

1.1kg

Ezy-RAD Pro AH-Pack

265kg

Control console

1.1kg

200mAs unit (AH-Pack) Bucky unit UD-PC, Phototimer control Direct phototimer pickup

Hand switch

Hand switch

Communication option ( 2)

Communication option ( 2) Reference skin dose indicator

Reference skin dose indicator

(

R=10 : 1, N=40lines/cm, fo=100cm, spacer=Al

Size of loadable cassette

*(

430 (16.9)

430 (16.9)

Control console

550mm (21.7”)

X-ray grid

Control cabinet including the X-ray high voltage generator

(Including the control cabinet and high voltage generator) 270kg

wood or soft synthetic leather (selectable)

Table height

170 (6.7)

) : With 200mAs unit

High voltage generator

Weight

1868×720mm (73.5”×28.3”)

Table top material

cm or inch size cassette based on IEC standard 60406

Standard equipment Radiographic system

Size of table top

55 (2.2)

680 (26.8)

170 (6.7)

Vertical travel (focus - floor distance)

Longitudinal travel (Along the guide rail) 1050mm (41.3”)

Radiographic table

Ezy-RAD Pro M-Pack

100kJ (140kHU)

850 - 1750mm (33.4” - 68.9”)

X-ray tube rotation on the horizontal axis

680 (26.8)

1.2mm

Max. anode heat capacity

240mm

Control console

     1.5kVA

Operation : Manual, Electromagnetic lock

Transverse travel (towards operator)

1)

220 (8.7)

Effective focus size

Focus movement

Operation : Manual, Electromagnetic lock

Cabinet

     20kVA

X-ray tube support unit 820 - 1750mm (32.2” - 68.9”)

(

Transformer capacity X-ray tube unit

X-ray tube support unit Focus movement

       Single Phase AC / 50Hz or 60Hz 100 / 110 / 120 / 200 / 220 / 230 / 240V  200 / 220 / 230 / 240V

850 (33.5)

90°

Effective focus size

90°

Nominal supply voltage

System / Frequency

X-ray tube unit

90°

0.0025 - 1.6sec (0.0025 - 3.2sec)*

Timer setting range

(

2) Some CR models may be not compatible with EZy-Rad Pro. Please contact Shimadzu sales representative office for more details.

( 1) Lieder cassette stand is not included.

(

2) Some CR models may be not compatible with EZy-Rad Pro. Please contact Shimadzu sales representative office for more details.

7