Alarm List [PDF]

  • 0 0 0
  • Gefällt Ihnen dieses papier und der download? Sie können Ihre eigene PDF-Datei in wenigen Minuten kostenlos online veröffentlichen! Anmelden
Datei wird geladen, bitte warten...
Zitiervorschau

display alarm list all --------------------------------------------------------ALARMID OUTPUT ALARM_NAME --------------------------------------------------------0x02210915 YES Anti-theft authentication of the extended frame fails 0x02220915 YES Anti-theft authentication of the extended frame succeeds 0x02310000 YES The communication between the board and the control board fails 0x02310018 YES The board hardware is abnormal 0x0231001d YES The communication between the extended frame and the main frame fails 0x02310083 YES Software fault occurs in board FPGA 0x023100a8 YES The power input of the local shelf fails 0x023100a9 YES Data synchronization between the active and standby control boards is canceled 0x023100be YES The inner power fault 0x023100ed YES Board software automatic expansion failure 0x023108ae YES The dying-gasp of extended frame occurs 0x02310cf0 YES The pluggable memory is faulty 0x02320000 YES The communication of the board with the control board recovers 0x02320018 YES The board hardware abnormity recovers 0x0232001d YES The communication of the main frame and the extended frame recovers 0x02320083 YES Software fault in board FPGA recovers 0x023200a8 YES The power input of the local shelf recovers 0x023200a9 YES Data synchronization between the active and standby control boards recovers 0x023200be YES The inner power recovered 0x023200ed YES Board software automatic expansion success 0x023208ae YES The dying-gasp of extended frame recovers 0x02320cf0 YES The pluggable memory recovers 0x02410019 YES The control board is in the over-temperature protection mode 0x0241a00d YES The ambient temperature for the board is too high 0x0241a00e YES The ambient temperature for the board is too low 0x02420019 YES The control board quits the over-temperature protection mode 0x0242a00d YES The high ambient temperature recovers to the normal range 0x0242a00e YES The low ambient temperature recovers to the normal range 0x0a11a055 YES The ADSL port activation rate fails to reach the rate threshold 0x0a12a055 YES The ADSL port activation rate succeeds in reaching the rate threshold 0x0a310007 YES Loss of signal occurs at the E1/T1 port 0x0a310008 YES Loss of frame alignment occurs at the E1/T1 port 0x0a310009 YES Receive remote alarm occurs at the E1/T1 port 0x0a31000a YES Loss of multiframe alignment occurs at the E1/T1 port 0x0a31000b YES Alarm indication signal occurs at the E1/T1 port 0x0a310012 YES CRC error occurs at the E1/T1 port 0x0a310019 YES The ADSL chipset is not available 0x0a310021 YES The upstream ethernet port connection fails or the state of it is abnormal 0x0a31002a YES The temperature of the Ethernet optical port is too high 0x0a31002c YES The adaptive clock source fails to be recovered from the bound service

0x0a310032 0x0a310036

YES YES

0x0a310038

YES

0x0a310092 0x0a3100fd 0x0a31a0dd 0x0a31a0de 0x0a31a0e2 0x0a31a0e3 0x0a31a0e6

YES YES YES YES YES YES YES

0x0a31a0e7

YES

0x0a31a0e8 0x0a31a0e9

YES YES

0x0a31a0ea

YES

0x0a31a0eb

YES

0x0a31a0ec

YES

0x0a31a0ed

YES

0x0a31a0ee

YES

0x0a31a0f0

YES

0x0a31a0f1

YES

0x0a320007 0x0a320008 0x0a320009 0x0a32000a 0x0a32000b 0x0a320012 0x0a320019 0x0a320021

YES YES YES YES YES YES YES YES

0x0a32002a

YES

0x0a32002c 0x0a320032 0x0a320036 0x0a320038

YES YES YES YES

0x0a320092 0x0a3200fd 0x0a32a0dd 0x0a32a0de 0x0a32a0e2 0x0a32a0e3

YES YES YES YES YES YES

Port type adaptation fault Load power of the Power over Ethernet port exceeds the upper limit Overcurrent for the power supply of the Power over Ethernet port The G.SHDSL chipset is not available The loss of link (LOL) occurs in the BITS input port The Ethernet port link status changes from up to down The optical transceiver is absence The LOS occurs on the Ethernet optical port Link between stack ports fails The TX output power of the Ethernet optical port is higher than the upper threshold or lower than the lower threshold The RX received power of the Ethernet optical port is higher than the upper threshold or lower than the lower threshold The remote device is powered off The temperature of the Ethernet optical port is higher than the upper threshold or lower than the lower threshold The current of the Ethernet optical port is higher than the upper threshold or lower than the lower threshold The voltage of the Ethernet optical port is higher than the upper threshold or lower than the lower threshold The current of the thermoelectric cooler on the Ethernet optical port is higher than the upper threshold or lower than the lower threshold The temperature of the optical laser on the Ethernet port is higher than the upper threshold or lower than the lower threshold The wavelength sent by the optical transceiver on the Ethernet port is higher than the upper threshold or lower than the lower threshold The performance statistics value of the ETH port exceeds the alarm threshold The performance statistics value of the ETH port exceeds the warning threshold Loss of signal(LOS) recover at the E1/T1 port Loss of frame recover at the E1/T1 port Remote alarm recover at the E1/T1 port Loss of multiframe alignment recover at the E1/T1 port Alarm indication signal recover at the E1/T1 port CRC recover at the E1/T1 port The ADSL chipset recovers The upstream ethernet port connection failure recovers or the state of it is normal The temperature of the Ethernet optical port recovers to the normal range The adaptive clock source restore Port type adaptation fault recovery Load power of the Power over Ethernet port recovers Overcurrent for the power supply of the Power over Ethernet port recovers The G.SHDSL chipset recovers from a fault The BITS input port recovers from loss of link (LOL) The Ethernet port link status changes from down to up The optical transceiver recovers to the normal state The Ethernet optical port recovers from LOS Link between stack ports on the boards to be bound

0x0a32a0e6

YES

0x0a32a0e7

YES

0x0a32a0e8 0x0a32a0e9

YES YES

0x0a32a0ea

YES

0x0a32a0eb

YES

0x0a32a0ec

YES

0x0a32a0ed

YES

0x0a32a0ee

YES

0x0a32a0f0

YES

0x0a32a0f1

YES

0x0c310001 0x0c320001 0x11310020 0x11310023

YES YES YES YES

0x11310025

YES

0x11310027

YES

0x11310028

YES

0x11310029

YES

0x11320020 0x11320023 0x11320025 0x11320027 0x11320028 0x11320029

YES YES YES YES YES YES

0x13010001

YES

0x13020001

YES

0x1411000b

YES

0x1411000c

YES

0x1412000b 0x1412000c 0x14310000

YES YES YES

0x14310001

YES

0x14310002

YES

0x14310003

YES

returns to a normal status The TX output power of the Ethernet optical port returns to the normal range The RX received power of the Ethernet optical port returns to the normal range The remote device is powered on The temperature of the Ethernet optical port recovers to the normal range The current of the Ethernet optical port recovers to the normal range The voltage of the Ethernet optical port recovers to the normal range The current of the thermoelectric cooler on the Ethernet optical port recovers to the normal range The temperature of the optical laser on the Ethernet port recovers to the normal range The wavelength sent by the optical transceiver on the Ethernet port recovers to the normal range The performance statistics value of the ETH port recovers to a value lower than the alarm threshold The performance statistics value of the ETH port recovers to a value lower than the warning threshold SPC is disconnected SPC is recovered Loss of cell delimitation (LOCD) occurs at the ATM port Loss of pointer (LOP) occurs at the SDH layer of the ATM port The ATM port receives the path alarm indication signals from the far end The ATM port receives the path remote defect indication signals from the far end Out of frame(OOF) occurs at the SDH layer of the ATM port The loss of receiving reference clock occurs at the ATM port Loss of cell delimitation (LOCD) recovery Loss of pointer (LOP) recovery Path alarm indication signal (PAIS) recovery Path remote defect indication (PRDI) recovery Out of frame (OOF) recovery Loss of receiving reference clock recovery at the ATM port Communication between the VAG and the SIP proxy server is interrupted Communication between the VAG and the SIP proxy server recovers A TDM connection fault occurs between the peer end and its connected equipment The TDM connection fault occurs between the local device and the peer end The TDM connection AIS recovers from the abnormal state The TDM connection RDI recovers from the abnormal state The signal degrades on the line connected to the STM port The port receives the remote defect indication signal of the tributary layer of the peer end The AIS is abnormal on the line connected to the STM port The port receives the remote defect indication signal of the line of the peer end

0x14310004 0x14310005 0x14310006 0x14310007

YES YES YES YES

0x14310008

YES

0x14320000 0x14320001

YES YES

0x14320002 0x14320003

YES YES

0x14320004 0x14320005 0x14320006

YES YES YES

0x14320007 0x14320008 0x1531a000 0x1531a24d 0x1532a000 0x1532a24d 0x15411001 0x15411005 0x15411010 0x15411012 0x15411015 0x15411018 0x1541101a 0x1541101b 0x15411020 0x15411027 0x15411100 0x15411101 0x15411102 0x15411103 0x15411104 0x15411105 0x15411106 0x15411108 0x1541110a 0x1541110b 0x1541110c 0x1541110d 0x1541110e 0x1541110f 0x15411110 0x15411111 0x15411112 0x15411113 0x15411114 0x15411115 0x15411201

YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES

0x15411202 0x15411203 0x15411204 0x15411220 0x15411221

YES YES YES NO NO

The SDH layer frames of the port are lost The port fails to receive signals The AIS of the tributary layer is abnormal A fault occurs between the peer end and its connected equipment The connection fault occurs between the local device and the peer end The signal degradation recovers The remote defect indication signal of the tributary layer recovers from the abnormal state The AIS of the line recovers from the abnormal state The remote defect indication signal of the line recovers from the abnormal state The frame loss recovers The port recovers from signal receiving failure The AIS of the tributary layer recovers from the abnormal state The remote AIS recovers from the abnormal state The remote RDI recovers from the abnormal state The communication of the EMU with the host is abnormal Batteries are not detected The communication of the EMU with the host recovers Batteries recover The unnamed analog parameter is abnormal The unnamed digital parameter is abnormal The battery will power off The AC power is off The battery loop is broken The load fuse is broken Battery charging over-current alarm The battery set is undervoltage The rectifier module is abnormal Battery discharging over-current alarm The AC voltage is out of the normal range The AC switch is turned off The battery voltage is out of the normal range The battery fuse has burned The load fuse has burned The rectifier module is abnormal The DC power is abnormal The door is opened Theft alarm The MDF is abnormal The fan is abnormal Fire alarm Smoke alarm The water monitor reports an alarm The diesel is abnormal The odor monitor reports an alarm The air-conditioning is abnormal The lightning arrester is faulty The DC voltage is abnormal by digital parameter monitor The output control switch is abnormal The temperature is out of the normal range by analog parameter monitor The humidity is out of the normal range The DC voltage is out of the normal range The current is out of the normal range Power module error Power module circuit error

0x15411256 0x1541125b 0x1541125d 0x1541125e 0x15411261 0x15411265 0x15411267 0x1541a009 0x1541a00b 0x1541a023 0x1541a024 0x1541a025 0x1541a026

YES YES YES YES YES YES YES YES YES YES YES YES YES

0x1541a24c 0x15421001

YES YES

0x15421005

YES

0x15421010 0x15421012 0x15421015 0x15421018 0x1542101a 0x1542101b 0x15421020 0x15421027 0x15421100 0x15421101 0x15421102 0x15421103 0x15421104 0x15421105 0x15421106 0x15421108 0x1542110a 0x1542110b 0x1542110c 0x1542110d 0x1542110e 0x1542110f 0x15421110 0x15421111 0x15421112 0x15421113 0x15421114 0x15421115 0x15421201

YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES

0x15421202 0x15421203 0x15421204 0x15421220 0x15421221 0x15421256 0x1542125b 0x1542125d 0x1542125e 0x15421261 0x15421265

YES YES YES NO NO YES YES YES YES YES YES

Battery Low-Temperature alarm Battery 1 Temperature Sensor fault alarm Environment Humidity Sensor fault alarm Environment 1 Temperature Sensor fault alarm Mismatched power module Battery High-Temperature alarm Battery over voltage alarm The AC input voltage is abnormal The DC voltage is abnormal An exception occurs in the EMU hardware The fan is blocked and therefore stops rotation The temperature is out of the normal range Two or more than two fans blocked and therefore stops rotation Battery Temperature out of normal range The value of the unnamed analog parameter recovers to the normal range The value of the unnamed digital parameter recovers to the normal range The battery recovers from power-off The power supply of the AC recovers The battery loop recovers The load fuse recovers battery charging over-current recovery alarm The battery set recovers from undervoltage The rectifier module recovers battery discharging over-current recovery alarm The AC voltage recovers to the normal range The AC switch recovers The battery voltage recovers The battery fuse recovers The load fuse recovers The rectifier module recovers from a fault The DC recovers The door is closed The theft alarm is cleared The MDF recovers The fan recovers The fire alarm is cleared The smoke alarm is cleared The water alarm is cleared The diesel recovers The odor alarm is cleared The air-conditioning recovers The lightning arrestor recovers from a fault The DC voltage recovers The output control switch recovers The temperature recovers to the normal range by analog parameter monitor The humidity recovers to the normal range The DC voltage recovers to the normal range The current recovers to the normal range Power module recovered Power module circuit recovered Battery Low-Temperature recovery alarm Battery 1 Temperature Sensor recovers Environment Humidity Sensor recovers Environment 1 Temperature Sensor recovers Power module recovers Battery High-Temperature recovery alarm

0x15421267 0x1542a009 0x1542a00b 0x1542a023 0x1542a024 0x1542a025 0x1542a026 0x1542a24c 0x17310007 0x17320007 0x1a010001 0x1a020001 0x1e010008 0x1e020008 0x28110039

YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES

0x28110049

NO

0x28120039

YES

0x28120049

NO

0x29110001 0x29110002 0x29110004 0x29120001 0x29120002 0x29120004 0x2d31a001

YES YES YES YES YES YES YES

0x2d31a005

YES

0x2d31a006 0x2d31a007 0x2d31a009 0x2d31a00a 0x2d31a00b 0x2d31a00c 0x2d32a001

YES YES YES YES YES NO YES

0x2d32a005

YES

0x2d32a006 0x2d32a007 0x2d32a009 0x2d32a00a

YES YES YES YES

0x2d32a00b 0x2d32a00c 0x2e111999 0x2e112001 0x2e112002 0x2e112003 0x2e112004 0x2e112006 0x2e112007

YES NO YES YES YES YES YES YES YES

0x2e112008 0x2e112009

YES YES

Battery over voltage recovery alarm The AC input voltage recovers The DC output voltage recovers An exception occurs in the EMU hardware recovers The fan blocking recovers The temperature recovers to the normal range The critical multi-fan blocking recovers Battery Temperature recovery alarm The MELT chip is faulty The MELT chip recovers H.248 interface interruption H.248 interface recovery L2UA link set is deactivated L2UA link set is activated The number of occupied IP neighbor hardware entries exceeds the upper threshold The number of occupied IP route hardware entries exceeds the upper threshold The number of occupied IP neighbor hardware entries is restored to the permitted range The number of occupied IP route hardware entries is restored to the permitted range The ring topology in the subscriber port is found The ring topology in the PON port is found The ring topology in the PON port is found The ring topology in the subscriber port is cleared The ring topology in the PON port is cleared The ring topology in the PON port is cleared The input signal of the one external clock source is lost The input signal of the 1588 external clock source is lost Clock is not in tracing mode Loss of ESMC The 1588 clock source fails to be locked The asymmetry measure value is too large The input QL of the clock source fails Output of the external clock is closed The input signal of the one external clock source recovers The input signal of the external 1588 clock source recovers Clock is in tracing mode Loss of ESMC recovers The 1588 clock source recovers to the locked state The asymmetry measure value recovers to the normal range The input QL of the clock source recovers Output of the external clock is opened The ONT initiative to go offline The RDIi occurs The loss of GEM channel delineation (LCDGi) occurs The signal degrade of ONTi (SDi) occurs The signal fail of ONTi (SFi) occurs The loss of frame of ONTi (LOFi) occurs The distribute fiber is broken or the OLT cannot receive expected optical signals from the ONT(LOSi/LOBi) The ONT works in emergency channel mode The statistics of GPON ONT FEC downstream correctable code words exceed alarm threshold

0x2e11200a

YES

0x2e1130ff

NO

0x2e11999a

YES

0x2e11999c 0x2e11999e 0x2e11999f 0x2e11a001

YES YES YES YES

0x2e11a002 0x2e11a009 0x2e11a00a

YES YES YES

0x2e11a00b 0x2e11a00c 0x2e11a00f 0x2e11a104 0x2e11a107 0x2e11a523

YES YES YES YES YES YES

0x2e11a524 0x2e121999 0x2e122001 0x2e122002 0x2e122003 0x2e122004 0x2e122006 0x2e122007

YES YES YES YES YES YES YES YES

0x2e122008 0x2e122009

YES YES

0x2e12200a

YES

0x2e1230ff 0x2e12999a

NO YES

0x2e12999c 0x2e12999e 0x2e12999f 0x2e12a001

YES YES YES YES

0x2e12a002

YES

0x2e12a009 0x2e12a00a

YES YES

0x2e12a00b 0x2e12a00c

YES YES

0x2e12a00f 0x2e12a104

YES YES

0x2e12a107 0x2e12a523

YES YES

The statistics of GPON ONT FEC downstream uncorrectable code words exceed alarm threshold A DoS attack caused by ONT management messages occurs on the PON port The active/standby status of the protection group member is different from that of the remote device One or more ONTs under this port failed in ranging The downstream signal degrade (SD) of the ONT occurs The downstream signal fail (SF) of the ONT occurs The feeder fiber is broken or OLT can not receive any expected optical signals(LOS) The hardware of the GPON port is faulty The deactivation failure of ONTi (DFi) occurs The loss of acknowledgement PLOAM message with ONTi ( LOAi) occurs The dying-gasp of GPON ONTi (DGi) is generated The loss of PLOAM of ONTi occurs(LOAMi/LOPCi) The physical equipment error of ONTi (PEEi) occurs The number of ONT LOOCis exceeds the alarm threshold The status of ONT's E1/T1 port is abnormal The backbone fiber on the port in Type B protection group is broken or the expected optical signal is not detected The number of ONT DOWis exceeds the alarm threshold The ONT initiative to go offline recovers The RDIi recovers The loss of GEM channel delineation (LCDGi) recovers The signal degrade of ONTi (SDi) recovers The signal fail of ONTi (SFi) recovers The loss of frame of ONTi (LOFi) recovers OLT can receive expected optical signals from ONT(LOSi/ LOBi recovers) The working mode of the ONT recovers The statistics of GPON ONT FEC downstream correctable code words return to the range within the threshold The statistics of GPON ONT FEC downstream uncorrectable code words return to the range within the threshold The ONT stops the DoS attack on management messages The active/standby status of the protection group member returns to be the same as that of the remote device No ONT under this port failed in ranging The downstream signal degrade (SD) of the ONT recovers The downstream signal fail (SF) of the ONT recovers OLT can receive expected optical signals from ONTs(LOS recovers) The optical transceiver hardware of the GPON port recovers from fault The deactivation failure of ONTi (DFi) recovers The loss of acknowledgement PLOAM message with ONTi ( LOAi) recovers The dying-gasp of GPON ONTi (DGi) recovers The loss of PLOAM of ONTi recovers(LOAMi/LOPCi recovers) The physical equipment error of ONTi (PEEi) recovers The number of ONT LOOCis reduces to the restore threshold The status of ONT's E1/T1 port recovers The port in Type B protection group receives the expected optical signal

0x2e12a524

YES

0x2e21a102 0x2e21a103 0x2e22a102 0x2e22a103 0x2e313015 0x2e313016 0x2e313017 0x2e313018 0x2e313019

YES YES YES YES YES YES YES YES YES

0x2e31301a 0x2e313024

YES YES

0x2e313025 0x2e31302a 0x2e31305c

YES YES YES

0x2e31305e

YES

0x2e31305f

YES

0x2e313060

YES

0x2e313062

YES

0x2e314020 0x2e314021

YES YES

0x2e314022 0x2e31999b 0x2e31999d 0x2e31a01b 0x2e31a034 0x2e323015 0x2e323016 0x2e323017 0x2e323018 0x2e323019 0x2e32301a 0x2e323024

YES YES YES YES NO YES YES YES YES YES YES YES

0x2e323025

YES

0x2e32302a

YES

0x2e32305c

YES

0x2e32305e

YES

0x2e32305f

YES

0x2e323060

YES

0x2e323062

YES

0x2e324020

YES

0x2e324021

YES

The number of ONT DOWis reduces to the restore threshold The GPON ONT configuration recovery fails The APS protocol of remote protection group is fault The GPON ONT configuration recovery is successful The APS protocol of remote protection group recovers The hardware of the ONT is faulty The ONT switches to the standby battery The standby battery of the ONT is lost The standby battery of the ONT cannot be charged The voltage of the standby battery of the ONT is too low The shell of the ONT is opened The loss of signals occurs on the ethernet port of the ONT No signal is received in the video UNI of the ONT The E1/T1 port loss of signal (LOS) occurs at the ONT Local optical transceiver parameters exceed alarm threshold Remote optical transceiver parameters exceed alarm threshold Numerous ONTs connected to the PON port are powered off concurrently Local optical transceiver parameters exceed warning threshold Remote optical transceiver parameters exceed warning threshold The optical transceiver of the PON port is absent There are illegal incursionary rogue ONTs under the port The ONT is rogue ONT The ONT temperature exceeds the alarm threshold The ONT voltage exceeds the alarm threshold The xPON MAC chipset is fault The power consumption of the ONT is overloaded The ONT recovers from the fault of hardware The external power supply of the ONT recovers The ONT recovers from the loss of standby battery The standby battery of the ONT recovers The voltage of the standby battery of the ONT recovers The shell of the ONT is closed The ethernet port of the ONT recovers from the loss of signals The video UNI of the ONT recovers from the loss of signals The E1/T1 port of the ONT recovers from loss of signal (LOS) Local optical transceiver parameters exceed alarm threshold recover Remote optical transceiver parameters exceed alarm threshold recover The ONTs which are powered off concurrently start to recover Local optical transceiver parameters exceed warning threshold recover Remote optical transceiver parameters exceed warning threshold recover The optical transceiver of the PON port recovers to the normal state The illegal incursionary rogue ONTs under the port have

0x2e324022 0x2e32999b 0x2e32999d 0x2e32a01b 0x2e32a034 0x2f210001 0x2f210002

YES YES YES YES NO YES YES

0x2f210003

YES

0x2f210004

YES

0x2f210005 0x2f210006 0x2f220001

YES YES YES

0x2f220002

YES

0x2f220003

YES

0x2f220004

YES

0x2f220005

YES

0x2f220006

YES

0x31210001 0x31220001 0x34010001 0x34020001 0x3641a001 0x3642a001

YES YES YES YES YES YES

0x3a010002 0x3a01001c

YES YES

0x3a010022 0x3a010024 0x3a010025 0x3a020002 0x3a02001c

YES YES NO YES YES

0x3a020022

YES

0x3a020024

YES

0x3a020025 0x3a310010 0x3a310018 0x3a310028 0x3a320010 0x3a320018 0x3a320028 0x3b010008 0x3b020008 0x3d310008 0x3d310022 0x3d310025 0x3d310028

NO YES YES YES YES YES YES NO NO YES YES YES YES

been cleared The rogue ONT disappears The ONT temperature becomes normal The ONT voltage becomes normal The xPON MAC chipset recovers from fault The power supply of the ONT is normal Loss of Ethernet connectivity check message Reception of invalid Ethernet connectivity check message Reception of Ethernet cross connect connectivity check message Reception of Ethernet connectivity check message with the RDI bit set At least one remote MEP's interface is not up Port is deactivated due to Ethernet connectivity fault Recovery of Ethernet connectivity check message loss defect Recovery of invalid Ethernet connectivity check message defect Recovery of Ethernet cross connect connectivity check message defect Recovery of Ethernet connectivity check message with RDI defect Recovery of down interfaces on which all remote MEPs are configured Port is activated due to recovery of Ethernet connectivity fault The default password for user root is not changed The default password for user root is changed MGCP interface interruption MGCP interface recovery The system resources usage exceeds the threshold The system resources usage recovers from the overload state to the normal state The physical line of the BRA port fails The CRC errors on the BRA port reach the alarm threshold CRC error count of E1 port reaches the alarm threshold Line error count of E1 port reaches the alarm threshold FXO port power fault Physical line of BRA port recovers CRC error count of BRA port recovers to normal after reaching the alarm threshold CRC error count of E1 port recovers to normal after reaching the alarm threshold Line error count of E1 port recovers to normal after reaching the alarm threshold FXO port power restore E1 line abnormal User line fault A/B line power abnormal E1 line normal User line normal A/B line power normal ISDN Layer-2 link abnormal ISDN Layer-2 link normal The VDSL chipset is unavailable Vectoring service on the board fails The port error sample feedback abnormal The port pilot sequence is abnormal

0x3d310029 0x3d310030 0x3d310031 0x3d310032

YES YES YES YES

0x3d320008 0x3d320022 0x3d320025 0x3d320028 0x3d320029 0x3d320030 0x3d320031 0x3d320032 0x3f010008 0x3f010009 0x3f01000a 0x3f01000b 0x3f01000c 0x3f01000d 0x3f01000e 0x3f020008 0x3f020009 0x3f02000a 0x3f02000b 0x3f02000c 0x3f02000d

YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES

0x3f02000e

YES

0x3f310000 0x3f320000 0x40010005 0x40020005 0x60010008 0x60020008 0x60110007 0x60110008 0x60112007

YES YES YES YES YES YES YES YES YES

0x6011a601

YES

0x6011a602

YES

0x6011a603

YES

0x6011a604

YES

0x60120007 0x60120008 0x60122007

YES YES YES

0x6012a601

YES

0x6012a602

YES

0x6012a603

YES

0x6012a604

YES

0x6031000b

YES

The port is activated in non-vectoring mode Vectoring services in the system fail The single-wire on the port is disconnected The port can not be activated by auto reset after offline The VDSL chipset recovers from unavailability Vectoring service on the board recovers The port error sample feedback recovers The port pilot sequence recovers The port is activated in vectoring mode Vectoring services in the system recover The single-wire on the port is re-connected The port is back to active after auto reset ONT SIP user authenticate fail ONT SIP user register timeout ONT SIP user register fail ONT MG interface fault A mass of ONT SIP users authenticate fail A mass of ONT SIP users register timeout A mass of ONT SIP users register fail ONT SIP user authenticate success ONT SIP user register success(timeout recovery) ONT SIP user register success(Error elimination) ONT MG interface recovery A mass of ONT SIP users authenticate success A mass of ONT SIP users register success(timeout recovery) A mass of ONT SIP users register success(Error elimination) The SLIC of the POTS service board is locked The SLIC of the POTS service board is unlocked The ANCP session is terminated The ANCP session is established Ring of ONT Ethernet port is detected Ring of ONT Ethernet port disappeared The EPON ONT configuration recovery fails The quality of the ONT optical path is poor The distribute fiber is broken or the OLT cannot receive expected optical signals from the EPON ONT(LOSi) The performance statistics value of the EPON port exceeds the alarm threshold The performance statistics value of the EPON port exceeds the warning threshold The performance statistics value of the ONT exceeds the alarm threshold The performance statistics value of the ONT exceeds the warning threshold The EPON ONT configuration recovery is successful The quality of the ONT optical path recovers OLT can receive expected optical signals from EPON ONT( LOSi recovers) The performance statistics value of the EPON port recovers to a value lower than the alarm threshold The performance statistics value of the EPON port recovers to a value lower than the warning threshold The performance statistics value of the ONT recovers to a value lower than the alarm threshold The performance statistics value of the ONT recovers to a value lower than the warning threshold The optical transceiver of the EPON OLT port is faulty

0x60311011 0x6031a033 0x6031a605

The dying-gasp of EPON ONTi (DGi) occurs The voltage of ONT's external power is abnormal The OLT optical module of this port does not support the ONT NNI type(s) on the port 0x6032000b YES The optical transceiver state of the port recovers 0x60321011 YES The dying-gasp of EPON ONTi (DGi) recovers 0x6032a033 YES The voltage of the external power of the ONT recovers 0x6032a605 YES The OLT optical module of this port supports the ONT NNI type(s) on the port 0x64110001 YES The MAC address occupancy in the system exceeds the upper threshold 0x64110002 YES The MAC address occupancy on the board exceeds the upper threshold 0x64120001 YES The MAC address occupancy in the system is restored to the permitted range 0x64120002 YES The MAC address occupancy on the board is restored to the permitted range --------------------------------------------------------CRP-H1(config)#

YES YES YES