26 0 22KB
OTIS 506 NCE/NCT Escalator/Travolator Quick Reference Display Code
Fault Code
EMERG.STOP START ACC OPER INSTRUCT HANDRAIL ENTRY START ACC OPER INSTRUCT OTIS GR3
S25/S26
OTIS GR4 (Upper Landing switches)
OTIS GR5 (Lower Landing switches)
OTIS GR6
OTIS B25 OTIS B26 OTIS S05 OTIS S06 OTIS B2 OTIS J OTIS NRD OTIS E12 OTIS E11 OTIS E14 OTIS E15 OTIS E16 OTIS E17 OTIS E18 OTIS E19 OTIS E20 OTIS E21 OTIS E22 OTIS S53 OTIS E26/E27
Reference
Emergency Stop Button upper or lower landing S21/S22 Handrail Entry switches right/left lower S23/S24 Handrail Entry switches right/left upper F3 Safety Circuit Fuse (ECB F1) S27 Governor Overspeed Switch S28 Broken Drive Chain Switch NRD Non Reversal Device S1 Left Hand Comb S2 Right Hand Comb S3 Left Hand Skirt Panel S4 Right Hand Skirt Panel S10/S64 Broken Step or Pallet S94 Right Hand Chain Wheel S95 Left Hand Chain Wheel S14 Right Hand Broken Step Chain S15 Left Hand Broken Step Chain S16 Left Hand Comb S17 Right Hand Comb S18 Right Hand Skirt Panel S19 Left Hand Skirt Panel S20/S65 Broken Step or Pallet S45 Left Hand Broken Handrail S46 Right Hand Broken Handrail Q3 Stop Switch (Pit) ASN Phase Device (low or reverse phase) B2 Motor Thermic Device S33 L/H Brake lifted contact S34 R/H Brake lifted contact Missing Step/Pallet upper landing Missing Step Pallet lower landing Floorplate upper landing Floorplate lower landing Motor Temperature contact Phase Reversal Non-reversal device – ECB Up & Down at same time – logic error No Up or Down while running – logic error KSU (Keyswitch Up) or KSD (Keyswitch Down) while on INS KSU signal & D relay or KSD & U relay Power fail 24V (VRS) KSU/D longer than 10 seconds Handrail slip right Handrail slip left Right Handrail slip LOCKED fault – too many slip errors Left Handrail slip LOCKED fault – too many slip errors No run signal within 2 seconds of KSU or KSD Emergency brake switch No Up/No Down – Check ECB on board relays.
LED’s on ECB Controller Name LED No.
State
1 2 3
NRD1 sensor NRD2 sensor Delta contactor
8
Remote Serial Link VLC - Voltage Level Converter
9
LED No. 4 5
Name (LED 4 OFF) Failure Operating Mode
6
Up
7
Down
LED No. 4
Name (LED 4 ON) Failure
5
Safety circuit
6
ECB
7
RSR4 contacts
on on on off blink off on off State
Description Machine running - NRD1 relay ‘in’ Machine running - NRD2 relay ‘in’ Delta operation - YD relay ‘in’ Star operation - YD relay ‘out’ RSL communication OK RSL communication stopped ECB supply OK No supply or reset
off on off blink blink on blink on
Failure (LED’s 5, 6 & 7 change function if LED 4 ON) Off indicates no failures Maintenance operation Continuous operation Intermittent operation Up selected - no start Up contactor, K1, active Down selected - no start Down contactor, K2, active
State
Failure
on blink off on off on off on
Not manual reset fault Manual reset fault – ECB Electrically Locked Safety contacts at RSFF OK Safety contact at RSFF open No failure on ECB ECB failure RSR4 contacts OK RSR4 contacts faulty
Relay No.
Name
Function
REL1
READY
REL2
UP
REL3
DOWN
Down direction relay
REL4
CHECK
Checks that UP, DOWN, READY, NRD1, NRD2, EOK and main motor contactors have dropped prior to starting
REL5
NRD1
Non Reverse Device - channel 1 OK
REL6
NRD2
Non Reverse Device - channel 2 OK
REL7
YD
Star-Delta contactor - YD in for Delta operation
REL8
EOK
Electronics OK - ECB, RSFF and RS4R all OK
REL9
GO
Maintains the UP or Down relays after starting Up direction relay
Controls main motor contactors
OTIS 506 NCE/NCT Escalator/Travolator Quick Reference Display Code
Fault Code
EMERG.STOP START ACC OPER INSTRUCT HANDRAIL ENTRY START ACC OPER INSTRUCT OTIS GR3
S25/S26
OTIS GR4 (Upper Landing switches)
OTIS GR5 (Lower Landing switches)
OTIS GR6
OTIS B25 OTIS B26 OTIS S05 OTIS S06 OTIS B2 OTIS J OTIS NRD OTIS E12 OTIS E11 OTIS E14 OTIS E15 OTIS E16 OTIS E17 OTIS E18 OTIS E19 OTIS E20 OTIS E21 OTIS E22 OTIS S53 OTIS E26/E27
Reference
Emergency Stop Button upper or lower landing S21/S22 Handrail Entry switches right/left lower S23/S24 Handrail Entry switches right/left upper F3 Safety Circuit Fuse (ECB F1) S27 Governor Overspeed Switch S28 Broken Drive Chain Switch NRD Non Reversal Device S1 Left Hand Comb S2 Right Hand Comb S3 Left Hand Skirt Panel S4 Right Hand Skirt Panel S10/S64 Broken Step or Pallet S94 Right Hand Chain Wheel S95 Left Hand Chain Wheel S14 Right Hand Broken Step Chain S15 Left Hand Broken Step Chain S16 Left Hand Comb S17 Right Hand Comb S18 Right Hand Skirt Panel S19 Left Hand Skirt Panel S20/S65 Broken Step or Pallet S45 Left Hand Broken Handrail S46 Right Hand Broken Handrail Q3 Stop Switch (Pit) ASN Phase Device (low or reverse phase) B2 Motor Thermic Device S33 L/H Brake lifted contact S34 R/H Brake lifted contact Missing Step/Pallet upper landing Missing Step Pallet lower landing Floorplate upper landing Floorplate lower landing Motor Temperature contact Phase Reversal Non-reversal device – ECB Up & Down at same time – logic error No Up or Down while running – logic error KSU (Keyswitch Up) or KSD (Keyswitch Down) while on INS KSU signal & D relay or KSD & U relay Power fail 24V (VRS) KSU/D longer than 10 seconds Handrail slip right Handrail slip left Right Handrail slip LOCKED fault – too many slip errors Left Handrail slip LOCKED fault – too many slip errors No run signal within 2 seconds of KSU or KSD Emergency brake switch No Up/No Down – Check ECB on board relays.
LED’s on ECB Controller Name LED No.
State
1 2 3
NRD1 sensor NRD2 sensor Delta contactor
8
Remote Serial Link VLC - Voltage Level Converter
9
LED No. 4 5
Name (LED 4 OFF) Failure Operating Mode
6
Up
7
Down
LED No. 4
Name (LED 4 ON) Failure
5
Safety circuit
6
ECB
7
RSR4 contacts
on on on off blink off on off State
Description Machine running - NRD1 relay ‘in’ Machine running - NRD2 relay ‘in’ Delta operation - YD relay ‘in’ Star operation - YD relay ‘out’ RSL communication OK RSL communication stopped ECB supply OK No supply or reset
off on off blink blink on blink on
Failure (LED’s 5, 6 & 7 change function if LED 4 ON) Off indicates no failures Maintenance operation Continuous operation Intermittent operation Up selected - no start Up contactor, K1, active Down selected - no start Down contactor, K2, active
State
Failure
on blink off on off on off on
Not manual reset fault Manual reset fault – ECB Electrically Locked Safety contacts at RSFF OK Safety contact at RSFF open No failure on ECB ECB failure RSR4 contacts OK RSR4 contacts faulty
Relay No.
Name
Function
REL1
READY
REL2
UP
REL3
DOWN
Down direction relay
REL4
CHECK
Checks that UP, DOWN, READY, NRD1, NRD2, EOK and main motor contactors have dropped prior to starting
REL5
NRD1
Non Reverse Device - channel 1 OK
REL6
NRD2
Non Reverse Device - channel 2 OK
REL7
YD
Star-Delta contactor - YD in for Delta operation
REL8
EOK
Electronics OK - ECB, RSFF and RS4R all OK
REL9
GO
Maintains the UP or Down relays after starting Up direction relay
Controls main motor contactors