WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-01-4
WELDER NAME : MANSA RAM
WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 01 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: DAPL-QC-WPS-01/ DAPL-QC-PQR-01
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W/28
LOCATION : DAPL CAMP
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : SMAW
MAINLINE
DATE OF TEST : 10.03.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 19.1 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
BOHLER ( E 6010)
3.2
73 - 107
22 - 34
171.42 - 240.00
HOT PASS
BOHLER ( E 8010)
4.0
112 - 146
27 - 35
206.89 - 222.22
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE :
R & HP - POSITIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
Vertical Down
Hot Pass :
Vertical Down
Subsequent Passes :
- N.A-
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/006 Dtd 11.03.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104 PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-08-1
WELDER NAME : S HAIDER RAZA
WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W 08
TEST COUPON NO.: DAPL-QC-WPS-01/ DAPL-QC-PQR-01
ADDRESS : DAPL SITE, JAJPUR
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W/47
LOCATION : DAPL CAMP
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : SMAW
MAINLINE
DATE OF TEST : 10.03.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 19.1 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
BOHLER ( E 6010)
3.2
73 - 107
22 - 34
171.42 - 240.00
HOT PASS
BOHLER ( E 8010)
4.0
112 - 146
27 - 35
206.89 - 222.22
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE :
R & HP - POSITIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
Vertical Down
Hot Pass :
Vertical Down
Subsequent Passes :
- N.A-
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/006 Dtd 11.03.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104 PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-05-1
WELDER NAME : PATI RAM MAHTO
WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 05
TEST COUPON NO.: DAPL-QC-WPS-01/ DAPL-QC-PQR-01
ADDRESS : DAPL SITE, JAJPUR
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W/38
LOCATION : DAPL CAMP
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 10.03.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 19.1 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
FILLER
BOHLER (E 81T8-FD)
2.0
190 - 270
20 - 28
150.00 - 240.00
CAPPING
BOHLER (E 81T8-FD)
2.0
205 - 275
20 - 28
192.69 - 220.86
Pass
ELECTRICAL CHARACTERISTICS :
DCEN
ELECTRODE :
F & C - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Minimum 2 Pass Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/006 Dtd 11.03.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104 PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-09-1
WELDER NAME : VIPIN KUMAR
WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 09
TEST COUPON NO.: DAPL-QC-WPS-01/ DAPL-QC-PQR-01
ADDRESS : DAPL SITE, JAJPUR
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W/36
LOCATION : DAPL CAMP
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 10.03.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 19.1 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
FILLER
BOHLER (E 81T8-FD)
2.0
190 - 270
20 - 28
150.00 - 240.00
CAPPING
BOHLER (E 81T8-FD)
2.0
205 - 275
20 - 28
192.69 - 220.86
Pass
ELECTRICAL CHARACTERISTICS :
DCEN
ELECTRODE :
F & C - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Minimum 2 Pass Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/006 Dtd 11.03.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104 PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : ADITYA SINGH
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-11-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 11 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM113/M14
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W/
LOCATION : DAPL-1 SPREAD
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 02.04.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
FILLER
BOHLER (E 81T8-FD)
2.0
195 - 270
21 - 28
187.50 - 200.00
CAPPING
BOHLER (E 81T8-FD)
2.0
216 - 275
21 - 28
200.00 - 214.28
Pass
ELECTRICAL CHARACTERISTICS :
DCEN
ELECTRODE :
F & C - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Minimum 2 Pass Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/009 Dtd 04.04.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104 PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : KAILASH SENAPATI
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-14-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 14 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM112/M79
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W/
LOCATION : DAPL-1 SPREAD
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 06.04.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
FILLER
BOHLER (E 81T8-FD)
2.0
170 - 244
23 - 29
187.50 - 200.00
CAPPING
BOHLER (E 81T8-FD)
2.0
218 - 281
22 - 28
193.54 - 214.28
Pass
ELECTRICAL CHARACTERISTICS :
DCEN
ELECTRODE :
F & C - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Minimum 2 Pass Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/020 Dtd 08.04.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : SHAKIL AHMED
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-15-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W 015 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM112/M75
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W/
LOCATION : DAPL CAMP
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : SMAW
MAINLINE
DATE OF TEST : 06.04.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
BOHLER ( E 6010)
3.2
94 - 117
26 - 34
214.28 - 200.00
HOT PASS
BOHLER ( E 8010)
4.0
122 - 153
38 - 47
214.28 - 200.00
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE :
R & HP - POSITIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
Vertical Down
Hot Pass :
Vertical Down
Subsequent Passes :
- N.A-
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/026 Dtd 13.04.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104 PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : RAJESH KUMAR
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-22-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 22 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM112/M31
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W/
LOCATION : DAPL-1 SPREAD
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 14.04.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
FILLER
BOHLER (E 81T8-FD)
2.0
190 - 270
20 - 28
187.50 - 200.00
CAPPING
BOHLER (E 81T8-FD)
2.0
233 - 272
22 - 28
187.50 - 200.00
Pass
ELECTRICAL CHARACTERISTICS :
DCEN
ELECTRODE :
F & C - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Minimum 2 Pass Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/027 Dtd 16.04.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : HARINDRA PRASAD
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-23-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 23 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM112/M31
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W/
LOCATION : DAPL-1 SPREAD
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 14.04.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
FILLER
BOHLER (E 81T8-FD)
2.0
187 - 272
28 - 36
176.47 - 187.5
CAPPING
BOHLER (E 81T8-FD)
2.0
218 - 264
26 - 34
181.81 - 193.54
Pass
ELECTRICAL CHARACTERISTICS :
DCEN
ELECTRODE :
F & C - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Minimum 2 Pass Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/027 Dtd 16.04.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : SANJAY KUMAR
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-24-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 24 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM112/M29
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W/
LOCATION : DAPL-1 SPREAD
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 14.04.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
FILLER
BOHLER (E 81T8-FD)
2.0
189 - 268
27 - 36
146.34 - 176.47
CAPPING
BOHLER (E 81T8-FD)
2.0
198 - 254
24 - 34
171.42 - 176.47
Pass
ELECTRICAL CHARACTERISTICS :
DCEN
ELECTRODE :
F & C - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Minimum 2 Pass Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/027 Dtd 16.04.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : SUNIL KUMAR
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-25-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 25 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM112/M29
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W/
LOCATION : DAPL-1 SPREAD
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 14.04.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
FILLER
BOHLER (E 81T8-FD)
2.0
194 - 270
20 - 28
142.85 - 157.89
CAPPING
BOHLER (E 81T8-FD)
2.0
199 - 258
20 - 27
146.34 - 206.89
Pass
ELECTRICAL CHARACTERISTICS :
DCEN
ELECTRODE :
F & C - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Minimum 2 Pass Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/027 Dtd 16.04.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : MD MUSTAKEEM ANSARI
WQT NO. : DAPL-QC-WQT-26-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 26 ADDRESS : DAPL SITE, JAJPUR
Doc. No. : PLL/DAPL/QA/MS/020-F-02
TEST COUPON NO.: KM112/M28
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W/
LOCATION : DAPL-1 SPREAD
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 14.04.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
FILLER
BOHLER (E 81T8-FD)
2.0
199 - 270
21 - 28
150.00 - 176.47
CAPPING
BOHLER (E 81T8-FD)
2.0
192 - 204
21 - 29
166.66 - 200.00
Pass
ELECTRICAL CHARACTERISTICS :
DCEN
ELECTRODE :
F & C - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Minimum 2 Pass Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/027 Dtd 16.04.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : JAWAHARLAL YADAV
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-27-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 27 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM112/M28
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W/
LOCATION : DAPL-1 SPREAD
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 14.04.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
FILLER
BOHLER (E 81T8-FD)
2.0
191 - 265
21 - 27
166.66 - 200.00
CAPPING
BOHLER (E 81T8-FD)
2.0
205 - 270
20 - 26
200.00 - 206.89
Pass
ELECTRICAL CHARACTERISTICS :
DCEN
ELECTRODE : (Filler Wire)
F & Cap - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Minimum 2 Pass Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/027 Dtd 16.04.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-28-1
WELDER NAME : SANJEEV KUMAR
WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 28 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM112/M07
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W/
LOCATION : DAPL-1 SPREAD
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 17.04.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
FILLER
BOHLER (E 81T8-FD)
2.0
191 - 266
20 - 27
187.5 - 200.00
CAPPING
BOHLER (E 81T8-FD)
2.0
195.3 - 244.2
20 - 26
187.5 - 200.00
Pass
ELECTRICAL CHARACTERISTICS :
DCEN
ELECTRODE : (Filler Wire)
F & Cap - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Minimum 2 Pass Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/039 Dtd 18.04.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : AMERJEET K PRASAD
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-03-4 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 03 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM120/M44
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W/27
LOCATION : DAPL CAMP
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : SMAW
MAINLINE
DATE OF TEST : 23.04.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
BOHLER ( E 6010)
3.2
100 - 128
33 - 40
193.54 - 200.00
HOT PASS
BOHLER ( E 8010)
4.0
124 - 158
38 - 48
240.00 - 214.28
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE :
R & HP - POSITIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
Vertical Down
Hot Pass :
Vertical Down
Subsequent Passes :
- N.A-
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/054 Dtd 24.04.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : GULAB CHAUHAN
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-04-4 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 04 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM120/M07
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : DAPL/INPL003/W/30
LOCATION : CH. 120
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : SMAW
MAINLINE
DATE OF TEST : 29.04.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
BOHLER ( E 6010)
3.2
82 - 103
32 - 40
214.28 - 250.00
HOT PASS
BOHLER ( E 8010)
4.0
124 - 158
38 - 48
214.28 - 240.00
FILLER
-
-
-
-
-
CAPPING
-
-
-
-
-
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE :
R & HP - POSITIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
Vertical Down
Hot Pass :
Vertical Down
Subsequent Passes :
- N.A-
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/073 Dtd 30.04.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
n
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : BIPUL MECH
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-29-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 29 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM120/M07
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : DAPL/INPL003/W/124
LOCATION : CH. 120
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : SMAW
MAINLINE
DATE OF TEST : 29.04.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
BOHLER ( E 6010)
3.2
91 - 114
32 - 40
300.00 - 333.33
HOT PASS
BOHLER ( E 8010)
4.0
131 - 172
37 - 47
333.33 - 400.00
FILLER
-
-
-
-
-
CAPPING
-
-
-
-
-
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE :
R & HP - POSITIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
Vertical Down
Hot Pass :
Vertical Down
Subsequent Passes :
- N.A-
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/073 Dtd 30.04.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : VINOD KUMAR YADAV
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-30-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 30 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM119/M80
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : DAPL/INPL003/W/127
LOCATION : CH. 119
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 02.05.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
-
-
-
-
-
HOT PASS
-
-
-
-
-
FILLER
BOHLER (E 81T8-FD)
2.0
182 - 262
21 - 27
206.89 - 230.76
CAPPING
BOHLER (E 81T8-FD)
2.0
214 - 281
21 - 27
222.22 - 230.76
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE : (Filler Wire)
F & Cap - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Minimum 2 Pass Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/083 Dtd 03.05.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : LAL BABU RAY
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-31-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 31 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM119/M80
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : DAPL/INPL003/W/126
LOCATION : CH. 119
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 02.05.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
-
-
-
-
-
HOT PASS
-
-
-
-
-
FILLER
BOHLER (E 81T8-FD)
2.0
192 - 264
20 - 26
200.00 - 214.28
CAPPING
BOHLER (E 81T8-FD)
2.0
214 - 281
21 - 27
200.00 - 214.28
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE : (Filler Wire)
F & Cap - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Minimum 2 Pass Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/083 Dtd 03.05.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : TAROON GOGOI
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-33-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 33 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM119/M08
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : DAPL/INPL003/W/136
LOCATION : DAPL 2, CH 119
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : SMAW
MAINLINE
DATE OF TEST : 09.05.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
BOHLER ( E 6010)
3.2
83 - 103
30 - 38
230.76 - 240.00
HOT PASS
BOHLER ( E 8010)
4.0
127 - 161
41 - 51
250.00 - 272.72
FILLER
-
-
-
-
-
CAPPING
-
-
-
-
-
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE :
R & HP - POSITIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
Vertical Down
Hot Pass :
Vertical Down
Subsequent Passes :
- N.A-
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/097 Dtd 09.05.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : BHUPEN CHETIA
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-34-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 34 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM118/M67
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : DAPL/INPL003/W/142
LOCATION : DAPL 2, CH 118
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : SMAW
MAINLINE
DATE OF TEST : 11.05.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
BOHLER ( E 6010)
3.2
93 - 118
31 - 43
153.84 - 162.16
HOT PASS
BOHLER ( E 8010)
4.0
119 - 156
40 - 51
150.00 - 166.66
FILLER
-
-
-
-
-
CAPPING
-
-
-
-
-
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE :
R & HP - POSITIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
Vertical Down
Hot Pass :
Vertical Down
Subsequent Passes :
- N.A-
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/104 Dtd 14.05.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : DIGANTO MAJUMDAR
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-35-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 35 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM118/M79
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : DAPL/INPL003/W/138
LOCATION : DAPL 2, CH 118
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : SMAW
MAINLINE
DATE OF TEST : 10.05.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
BOHLER ( E 6010)
3.2
80 - 100
31 - 40
153.84 - 166.66
HOT PASS
BOHLER ( E 8010)
4.0
117 - 150
37 - 49
157.89 - 162.16
FILLER
-
-
-
-
-
CAPPING
-
-
-
-
-
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE :
R & HP - POSITIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
Vertical Down
Hot Pass :
Vertical Down
Subsequent Passes :
- N.A-
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/103 Dtd 11.05.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : SADANAND KALITA
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-36-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 36 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM118/M79
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : DAPL/INPL003/W/139
LOCATION : DAPL 2, CH 118
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : SMAW
MAINLINE
DATE OF TEST : 10.05.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
BOHLER ( E 6010)
3.2
99 - 124
30 - 37
187.50 - 193.54
HOT PASS
BOHLER ( E 8010)
4.0
132 - 164
39 - 51
193.54 - 200.00
FILLER
-
-
-
-
-
CAPPING
-
-
-
-
-
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE :
R & HP - POSITIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
Vertical Down
Hot Pass :
Vertical Down
Subsequent Passes :
- N.A-
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/103 Dtd 11.05.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : PINKU KUMAR
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-37-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 37 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM118/M80
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : DAPL/INPL003/W/137
LOCATION : DAPL 2, CH 118
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 10.05.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
-
-
-
-
-
HOT PASS
-
-
-
-
-
FILLER
BOHLER (E 81T8-FD)
2.0
158 - 269
22 - 43
157.89 - 200.00
CAPPING
BOHLER (E 81T8-FD)
2.0
192 - 258
20 - 26
171.42 - 193.54
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE : (Filler Wire)
F & Cap - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
Vertical Down
Hot Pass :
Vertical Down
Subsequent Passes :
- N.A-
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/103 Dtd 11.05.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : ASHIM CHANGMAI
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-38-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 38 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM118/M80
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : DAPL/INPL003/W/140
LOCATION : DAPL 2, CH 118
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 10.05.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
-
-
-
-
-
HOT PASS
-
-
-
-
-
FILLER
BOHLER (E 81T8-FD)
2.0
142 - 250
21 - 28
166.66 - 187.50
CAPPING
BOHLER (E 81T8-FD)
2.0
192 - 264
20 - 27
193.54 - 200.00
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE : (Filler Wire)
F & Cap - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/103 Dtd 11.05.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : HARI PAL
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-39-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 39 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM118/M24
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : DAPL/INPL003/W/157
LOCATION : DAPL 2, CH 118
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 16.05.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
-
-
-
-
-
HOT PASS
-
-
-
-
-
FILLER
BOHLER (E 81T8-FD)
2.0
174 - 253
21 - 28
142.85 - 157.89
CAPPING
BOHLER (E 81T8-FD)
2.0
197 - 253
21 - 26
153.89 - 157.84
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE : (Filler Wire)
F & Cap - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/129 Dtd 18.05.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : BALINDRA MAHTO
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-40-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 40 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM118/M24
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : DAPL/INPL003/W/156
LOCATION : DAPL 2, CH 118
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 16.05.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
-
-
-
-
-
HOT PASS
-
-
-
-
-
FILLER
BOHLER (E 81T8-FD)
2.0
192 - 253
27 - 36
166.66 - 187.66
CAPPING
BOHLER (E 81T8-FD)
2.0
202 - 264
27 - 35
176.47 - 200.00
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE : (Filler Wire)
F & Cap - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/129 Dtd 18.05.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : SANTANU CHETIA
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-43-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 43 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM114/M40
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : DAPL/INPL003/W/159
LOCATION : DAPL 1, CH 114
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : SMAW
MAINLINE
DATE OF TEST : 21.05.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
BOHLER ( E 6010)
3.2
92 - 118
31 - 41
206.89 - 214.28
HOT PASS
BOHLER ( E 8010)
4.0
123 - 160
35 - 46
153.84 - 187.50
FILLER
-
-
-
-
-
CAPPING
-
-
-
-
-
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE :
R & HP - POSITIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
Vertical Down
Hot Pass :
Vertical Down
Subsequent Passes :
- N.A-
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/149 Dtd 25.05.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : LAKHWIR SINGH
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-32-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 32 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM 84 / M 68
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : H DEEP CONTRACTOR
LOCATION : DAPL 1, CH 84
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 20.06.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
-
-
-
-
-
HOT PASS
-
-
-
-
-
FILLER
BOHLER (E 81T8-FD)
2.0
209 - 275
20 - 26
171.42 - 200.00
CAPPING
BOHLER (E 81T8-FD)
2.0
195 - 251
20 - 25
200.89 - 200.00
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE : (Filler Wire)
F & Cap - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/293 Dtd 06.07.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : JOGINDER YADAV
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-16-2 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 16 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM 84 / M 08
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : H DEEP CONTRACTOR
LOCATION : DAPL 1, CH 84
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 20.06.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
-
-
-
-
-
HOT PASS
-
-
-
-
-
FILLER
BOHLER (E 81T8-FD)
2.0
203 - 275
20 - 26
181.81 - 206.89
CAPPING
BOHLER (E 81T8-FD)
2.0
207 - 265
20 - 26
214.28 - 222.22
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE : (Filler Wire)
F & Cap - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/235 Dtd 22.06.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : LAXMAN SINGH
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-10-2 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 10 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM 84 / M 09
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : H DEEP CONTRACTOR
LOCATION : DAPL 1, CH 84
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 20.06.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
-
-
-
-
-
HOT PASS
-
-
-
-
-
FILLER
BOHLER (E 81T8-FD)
2.0
210 - 221
20 - 21
171.42 - 200.00
CAPPING
BOHLER (E 81T8-FD)
2.0
196 - 204
20 - 21
193.54 - 200.00
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE : (Filler Wire)
F & Cap - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/235 Dtd 22.06.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : BHOLA DAS
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-17-3 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 17 ADDRESS : DAPL SITE, JAJPUR
TEST COUPON NO.: KM 84 / M 08
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : INVERTER
PASSPORT / I/C No. : H DEEP CONTRACTOR
LOCATION : DAPL 1, CH 84
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 20.06.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 15.9 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
-
-
-
-
-
HOT PASS
-
-
-
-
-
FILLER
BOHLER (E 81T8-FD)
2.0
210 - 275
20 - 26
206.89 - 250.00
CAPPING
BOHLER (E 81T8-FD)
2.0
196 - 266
21 - 26
206.89 - 222.22
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE : (Filler Wire)
F & Cap - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/235 Dtd 22.06.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : CHARANJIT BAKSHI
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-47-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 47 ADDRESS : DAPL SITE, JAJPUR ROAD
TEST COUPON NO.: KM127/M41
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W
LOCATION : DAPL 2, CH 127
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : SMAW
MAINLINE
DATE OF TEST : 14.09.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 19.1 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
BOHLER ( E 6010)
3.2
68 - 90
27 - 35
187.50 - 200.00
HOT PASS
BOHLER ( E 8010)
4.0
113 - 143
28 - 35
200.00 - 206.89
FILLER
-
-
-
-
-
CAPPING
-
-
-
-
-
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE :
R & HP - POSITIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
Vertical Down
Hot Pass :
Vertical Down
Subsequent Passes :
- N.A-
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/341 Dtd 15.09.18)
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : DHANIK LAL
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-48-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 48 ADDRESS : DAPL SITE, JAJPUR ROAD
TEST COUPON NO.: KM 127 / M 39
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W
LOCATION : DAPL 2, CH 127
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 15.09.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 19.1 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
-
-
-
-
-
HOT PASS
-
-
-
-
-
FILLER
BOHLER (E 81T8-FD)
2.0
189 - 243
20 - 27
187.50 - 200.00
CAPPING
BOHLER (E 81T8-FD)
2.0
194 - 245
19 - 25
187.50 - 200.00
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE : (Filler Wire)
F & Cap - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/342 Page 01 / 02 Dtd 18.09.18
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :
WELDER QUALIFICATION TEST RECORD (API 1104)
CLIENT : GAIL/ MECON
CONTRACTOR : PUNJ LLOYD LTD.
WELDER NAME : ARVIND KUMAR SINGH
Doc. No. : PLL/DAPL/QA/MS/020-F-02
WQT NO. : DAPL-QC-WQT-49-1 WPS NO. : DAPL-QC-WPS-01
WELDER I/D No. : W - 49 ADDRESS : DAPL SITE, JAJPUR ROAD
TEST COUPON NO.: KM 127 / M 37
PLACE FOR PHOTOGRAPH
WELDING M/C TYPE / SIZE : RECTIFIER
PASSPORT / I/C No. : DAPL/INPL003/W
LOCATION : DAPL 2, CH 127
NATIONALITY : INDIAN
WEATHER CONDITIONS : SUNNY
WELDING PROCESS : FCAW
MAINLINE
DATE OF TEST : 16.09.2018
PIPE AND FITTING MATERIALS : Linepipe API 5L Gr. X 70, PSL 2 TO API 5L Gr. X 70 , PSL 2 PIPE OUTSIDE DIAMETER : 914.4 MM
Range Qualified : Ø > 323.85 MM
PIPE WALL THICKNESS : 19.1 MM
Range Qualified : 4.8 MM ≤ T ≤ 19.1 MM
JOINT DESIGN Make and Type of Filler Material
Diameter MM
Current (Amps)
Voltage (Volts)
Travel Speed MM/Min
ROOT
-
-
-
-
-
HOT PASS
-
-
-
-
-
FILLER
BOHLER (E 81T8-FD)
2.0
190 - 246
20 - 26
187.50 - 200.00
CAPPING
BOHLER (E 81T8-FD)
2.0
194 - 246
19 - 25
193.54 - 200.00
Pass
ELECTRICAL CHARACTERISTICS :
DCEP
ELECTRODE : (Filler Wire)
F & Cap - NEGATIVE
WELD POSITION:
5G
SHIELDING FLUX:
CELLULOSIC
DIRECTION OF WELDING : Root Pass:
- N.A-
Hot Pass :
- N.A-
Subsequent Passes :
Vertical Down
Minimum Number of runs before joint as allowed to cool : Not Applicable Maximum time between commencement and completion of weld : Not Applicable TYPE OF LINE UP CLAMP :
( ü ) Internal
Removal of clamp after :
( ü ) 100%
CLEANING :
( ) External /
( )
( ) Tack Joints
50%
of Root Deposition
Power Brushing, Grinding & Chipping
INEPSCTION / NON DESTRUCTIVE EXAMINATION
Applicable Code
Required
Remarks
Visual Inspection
API 1104 (Section 6)
Yes
ACCEPTABLE
Radiography (Rep. No. DAPL/QC/RT/342 Page 01 / 02 Dtd 18.09.18
API 1104 (Section 8)
Yes
ACCEPTABLE
THE STATEMENTS IN THE RECORD ARE CORRECT. THE WELDER HAS COMPLETED THE W.Q.T. IN ACCORDANCE WITH THE REQUIREMENTS OF THE W.P.S., API 1104, MECON SPECIFICATION. PLL SIGN :
PLL SIGN :
CLIENT AUTHORITY SIGN :
NAME :
NAME :
NAME :
DATE :
DATE :
DATE :