SIGMA Elevator fault codes SIGMA Elevator fault codes E005 running CPU WDT software failure E006 memory failure E007 task creation failed E008 display case creation failed E009 running CPU WDT timer fault E010 appears to define non- vectored interrupt E016 CPU speed hardware WDT failure occurs E017 CPU speed retry failed E021 speed CPU DAMPR write failure E030 INC excessive current ( hardware ) E031 DC voltage is too large segment E032 INV U phase IGBT fault E033 INV V phase IGBT fault E034 INV W phase IGBT fault E035 regenerative IGBT fault E036 INV current transformer failure E037 INV overheating E038 LRT operational failure E041 INV fault current control E048 DC low voltage section E052 INV reverse phase detection E053 INV charging fault E054 overload detection INV E055 INV speed is too low to detect E056 high speed detection INV E057 brake current is too high E058 brake control failure E059 INV does not run through the 24S E060 INV specification data failure E061 INC specification writing failure E062 momentary power failure detection INV E069 fault detection phase 100V E070 48V power failure ( phase ) E071 isolated power ( control power ) E072 C1SW open failure E073 C1SW Close failure E074 operating specifications data failures E076 EEPROM write failure E077 EEPROM read error E078 EEPROM storey measurement error sum E079 NVRAM storey measurement error sum E084 R5SC fault relay ON E085 R5SC fault relay OFF E086 C1BR ON contactor failure E087 C1BR OFF contactor failure E088 C1ST ON contactor failure E089 C1ST OFF contactor failure E090 SUPPRESS ON failure E091 SUPPRESS OFF failure E092 R / E unwired E093 R / E pulse counter reading error E094 R / E pulse counter failure E095 R5SX off failure E096 operation mode input fault E097 CDS car door switch failure E098 LDS landing door switch failure E099 Dual input signal failure E100 SD1D switch ON failure
E101 SD1D OFF switch failure E107 SD1U switch ON failure E108 SD1U OFF switch failure E114 LDC switch ON failure E116 LDU switch ON failure E117 LDD switch ON failure E119 forced to change speed switch failure E120 UL failure E121 DL failure E125 brake open fault Between E126 and the speed of the system running at different speeds E127 DES PCB overheating ( no room ) E128 motor overheating E130 difference becomes failure E131 rope break up E132 appears to open the door blocked failure E133 door blocked repeated failure E134 blocked fault occurs close E135 blocked repeated failure to close E136 ALP failure ( 137 ) E139 fault forced to close E140 spare battery discharge E141 clock chip failure E145 CPU WDT door motor inverter fault E146 -conditioned water level switch failure E147 OBS failure occurs E150 SD1D overspeed detection switch E151 SD2D overspeed detection switch E157 SD1U overspeed detection switch E158 SD2U overspeed detection switch E164 emergency stop detection E168 speed difference E169 direction of fault E170 is running in the wrong direction E171 stop abnormal position E172 SD1U input error E173 SD1D input error E174 stop abnormal position E175 first layer abnormalities E176 SD ON failure E177 emergency stop on many occasions E178 rescue operation on many occasions E179 stop layer detects input failure POSI E182 running overload E184 SDS occurs repeatedly forced deceleration E188 OLS failure E190 2 Deceleration fault location E191 opening and closing commands while failure E192 door position fault E193 door motor voltage failure E194 door motor overheating E195 door motor current fault E196 photoelectric switch input fault E199 PCB protection failure E200 CNET LON communication failure E202 car communication failure E203 SUB run operation panel runtime exception ( car communication failure ) E204 residual abnormal operation with the main operation panel E205 residues vice operation panel with a runtime exception (DES PCB communicati on failure )
E206 rear side of the main operation panel abnormal operation E207 rear side of the operation panel deputy abnormal operation E208 CAR VMD communication failure No other ladder fault E211 E217 landing door button is stuck E223 hall call communication failure ( a ) E224 hall call communication failure ( all) E225 call all the faults in the first column E226 call all the faults in the second column E231 First VMD failure E232 second VMD failure E233 ESMI remote monitoring communication failure E238 MANI HALL G / A malfunction E239 GRT G / A fault ( landing door open fault ) E240 ESMI mode We can replace your sigma lift spare parts which need to repair parts