40 0 21MB
INSTRUCTION MANUAL
Jets Order No. 604209 Vacuum Toilet System Part 1: Installation Hyundai Mipo Dock Yard Co.Ltd. H-2037
Specification Jets Order No. 604209-12 Qty
Desciption
Part no.
1 1 2 8 2 2 1 1 1 4 4
Vacuum unit / STP Vacuum unit JETS 30MB-D JETS 15MB-D Vibration absorber Pressure switch 3-way test valve 3/8" BSP Vacuum gauge 3-way test valve 1/4" BSP Ball valve Ball valve DN50 Flange w/connecting pipe DN50
900399910 J30MB-D V 029015001 030303400 032300100 034308900 032300200 034308800 035301300 035319200 029152100
1
Sewage Treatment Plant
900399900
27 27 27 27 27 27
Toilet JETS 64 FD/VPC-V vac Toilet JETS 64 FD/VPC-V vac. Seat & Cover "Lily" Release button Mounting set Muff straight reduction
J64-FDVPCV Vac 064200050 069608700 100100040 069606403 034512901
3 3 3 3 3 3 3
Toilet JETS 50 FD/VPC-V vac. Toilet JETS 50 FD/VPC-V vac. Seat & Cover "Lily" Release button Mounting set Elbow rubber reduction Console, Release button
J50-FDVPCV Vac 063605010 069608700 100100040 069606405 034512801 100100700
2 2 1 1 1 1
Spare Parts: Shut-off membrane Lifting membrane Release button Flushing ring FD valve VPC Controller
050501200 050500800 100100040 069510610 054110100 101100010
Installation Instructions DATA SHEET NO
Storage and Maintenance Instruction
2163
ISSUE A
For Jets vacuumarators, vacuum units, toilets and related equipment
Storage: a) Storage before installation: Goods to be stored in a cool and dry place. b) From installation on board up to setting to work: Goods to be protected against dust, grinding, welding and moisture. c) From setting to work up to handing over the ship: As for b), especially to be protected against moisture.
Maintenance Instruction during storage: Environmental conditions: Goods to be stored indoor at a dry place. Visual inspections: Check for visual damage. Inspection intervals: Upon arrival and before installation. Maintenance: Not required. Maintenance Intervals: Not required. Tools: Not required.
Note: Changes without prior notice
JETS VACUUM AS
P.O.Box 14 N-6069 Hareid, Norway +47 70 03 91 00 Tel.: Fax: +47 70 03 91 01 E-mail: [email protected]
3
Installation Instructions
Installation Vacuumarator Vacuum unit
When designing the installation of the vacuum unit, it is important to provide sufficient space for inspection and maintenance. Install shut-off valves (included in Jets supply) according to piping diagram. Each vacuumarator is supplied with vibration dampers. Flexible joints (included in Jets supply) must be used when connecting the vacuumarator`s suction and pressure side. The vacuumarator must be located to avoid head loss on outlet pipe. Height of outlet pipe should be kept at a minimum, preferably less than 2 meters, because increased height of outlet pipe will reduce vacuum capacity of vacuumarator. If increased height is needed, please contact Jets Vacuum Technical Department. Please notice: For Vacuumarator Jets 15M, 15MB and Jets 15MB-D: To keep sufficient priming of the vacuumarator, outlet pipe should be at least 1 m long in vertical direction.
DATA SHEET NO
2108
ISSUE I
Rotation of the vacuumarators
The correct rotation is indicated with an arrow on the pump housing. The rotation of the pump is always clockwise seen from the motor fan end. Prior to checking the rotation, make sure that the vacuumarator is filled with liquid. Starting up the vacuumarators without liquid will damage the shaft seals.
Sewage treatment plant
If connected to a sewage treatment plant, the discharge pipe(s) from the vacuumarator(s) is connected to the plant. See treatment plant Instruction manual.
Integrated holding tank
Connected to an integrated holding tank, connections for vacuumarators must be made according to Technical Manual. Level switches for control of discharge pump(s) must be installed according to drawing in Technical Manual.
Fresh Water Supply
Fresh water supply may be connected to the suction chamber on each vacuumarator to flush and clean when neccessary and to fill the vacuumarator with water after service.
Note: Changes without prior notice
JETS VACUUM AS
P.O.Box 14 N-6069 Hareid, Norway +47 70 03 91 00 Tel.: Fax: +47 70 03 91 01 E-mail: [email protected]
4
Installation Instructions
DATA SHEET NO
Pressure switch Type:
3103
Technical data
Danfoss RT121 (-1 to 0 bar)
Ambient temperature:-40 to +70°C. Pressure connection temperature: max. 150°C. Enclosure: IP 66 acc. to IEC 529 and DIN 40050. Cable entry: Two Pg 13,5 entries for cable diameters from 5 to 14 mm. Pipe connection: 3/8" RG
Setting
The pressure switches shall be adjusted to recommended setpoints, see table below. See also: Data sheet no. 3105
ISSUE D
Switch
Contact load Alternating current: AC1 (ohmic): 10 A, 380 V AC3 (motor): 4 A, 380 V AC11 (coils): 3 A, 380 V 12 W, 220 V Direct current: El. connection: Start and stop: Terminal 1 and 4 Alarm low vacuum: Terminal 1 and 2
Adjustment
Pressure switch for start/stop 1. 2. 3. 4. 5. 6. 7. 8. 9.
Remove front cover Adjust “regulator” (1) to - 40 kPa (scale value) Adjust “rotating differential disc “(2) to 2.5 (scale value) Start Vacuumarator and observe vacuum gauge. At appr. - 45 kPa (% vacuum), switch the start/stop switch to “auto” position. Vacuumarator will stop. Drain air slowly into pipe system by opening ball valve on the pipe manifold. Close valve at - 40kPa ( % vacuum.) Adjust slowly “regulator” (1) till vacuumarator starts. Increase=Clockwise. Decrease=Counterclockwise. Adjust “rotating differential disc” (2) if necessary. Increase=Clockwise. Decrease=Counterclockwise. Repeat 6 through 8 until recommended setpoints are achieved.
Pressure switch for alarm
1. Regulator 2. Differential setting disc
Setpoints:
Start of pump: - 40 kPa ( % vacuum) Stop of pump: - 55 kPa ( % vacuum) Alarm low vacuum: - 25 kPa ( % vacuum)
1. 2. 3. 4. 5. 6.
Remove Front cover Adjust “regulator” (1) to - 25 kPa (scale value) Adjust “rotating differential disc” (2) to 1 (scale value) Start Vacuumarator and observe vacuum gauge. At appr.- 25 kPa (% vacuum), stop the Vacuumarator. Drain air slowly into pipe system by opening ball valve on the pipe manifold. 7. Check if the contact shifts at recommended setpoint. 8. If necessary adjust “regulator” (1). Increase=Clockwise. Decrease=Counterclockwise. 9. Repeat 4 through 8 until recommended setpoint is achieved.
ATTENTION:
Please note that the mentioned minus kPa in this instruction is only related to the marked scale value plate on the Danfoss RT121 Pressure Switch, and not to kPa standard in general. Note: Changes without prior notice.
JETS VACUUM AS
P.O.Box 14 N-6069 Hareid, Norway Tel.: +47 70 03 91 00 Fax: +47 70 03 91 01 E-mail: [email protected]
5
A
B
C
Porclain JETS 64 064110000
Approximately 670mm
D
6
Approximately 425mm
Toilet Seat/Cover See Order Spec.
Flushing Ring 069510611
Hose Clip See Mounting Kit
5
Spring 053531720
Rubber Sleeve See Mounting Kit
Hose Clip See Mounting Kit
4
Water Connection BSP 1/2"
20
280 260
70 80
3,5 Ø3
FD Valve w/VPC, Complete 054101070 Hose Clip See Mounting Kit
Vacuum Breaker must be mounted vertically, minimum 150mm higher than Flushing Ring.
Hose Clip See Mounting Kit
Hose See Mounting Kit
Hose Clip See Mounting Kit Release Button See Order Spec.
Parts in Mounting Kit (Part No. See Order Spec.) Description Qty Part No. 036601400 Washer 2 Spacer Sleeve 069600700 2 034505500 Rubber Sleeve 1 Hose Clip 034506900 2 Hose Clip 034233401 3 034507310 Vacuum breaker 1 034503111 Hose 1
320 4 �1
Vacuum Breaker See Mounting Kit
Ø50
4
340 330
5
110 60
6
3
WWW.JETS.NO
N-6069 HAREID Tel. +47 70 03 91 00 Fax. +47 70 03 91 01 E.Mail [email protected]
3
TM
1
Flushing Ring connection point
Connetion for Release Button Hose
2
Material:
Weight:
PART AND PIPE CONNECTION
TOILET JETS 64 FD/VPC-V vac
064200050
Part no.:
Title:
1
32909-064.idw
Drawing no.:
Project:
Scale:
Designed by: 22.12.2006
Date:
rhu
Sign:
Original Drawing Rev.:
15.01.2007 RHU 22.12.2006 rhu
Revised Title B
A
Description:
# NOT JETS DELIVERY * SEE MOUNTING KIT
�������������������������
2
A
B
C
D
Installation Instructions
31
A
B
C
6
Porcelain JETS 50 063602000
Flushing Ring 069510620
Toilet Seat/Cover See Order Spec.
Approximately 670mm
D
6
100
FD Valve w/ VPC-V, Complete 054101080
Sealing Ring 037503800
Hose Clip See Mounting Kit
5
Ø50
4
4
Hose Clip See Mounting Kit
Rubber Elbow See Mounting Kit
Water Connection BSP 1/2"
Cover 063602100
, 33 Ø
5
Fastening Sleeve 069602201
Parts in Mounting Kit (Part No. See Order Spec.) Description Qty Part No. 034507310 Vacuum Breaker 1 Rubber Elbow 034505400 1 Hose Clip 034506900 2 Hose Clip 034233401 3 034503118 Hose 1
Vacuum Breaker must be mounted vertically, minimum 150mm higher than Flushing Ring.
Hose Clip See Mounting Kit
Fastening Kit 036510203
Hose Clip See Mounting Kit
Hose See Mounting Kit
Release Button See Order Spec.
Hose Clip See Mounting Kit
Vacuum Breaker See Mounting Kit
5
WWW.JETS.NO
3
Connection for Release Button Hose
Flushing Ring connection point
2
TM
2
Material:
Weight:
PART AND PIPE CONNECTION
TOILET JETS 50 FD/VPC-V vac
063605010
Part no.:
Title:
1
32912-063.idw
Drawing no.:
Project:
Scale:
Designed by: 08.01.2007
rhu
Sign:
Original Drawing A
Date:
15.01.2007 RHU 08.01.2007 rhu
Revised Title Rev.:
16.01.2007 RHU
Revised part number
B
1
C
Description:
For Console mounting of Release Button, see detail drawing.
N-6069 HAREID Tel. +47 70 03 91 00 Fax. +47 70 03 91 01 E.Mail [email protected]
3
A
B
C
D
Installation Instructions
32
D
C
B
1
R10
2
2
430
3
R60
R10
3
5
55 212
19 36
A
1
WWW.JETS.NO
N-6069 HAREID Tel. +47 70 03 91 00 Fax. +47 70 03 91 01 E.Mail [email protected]
4
5
4
TM
A
Original Drawing Description
063608700
5
FIBRE GLASS
Material:
Drawing no
32505-063.idw 6
1:4
Date
Sign
Rev.
17.06.2004 RoL
1,75 Kg
Scale
Checked by
Designed by
17.06.2004 RoL
6
Weight:
BASE PLATE FOR TOILET JETS50
Part no.:
Title
Rev.
5
D
C
B
A
Installation Instructions
33
257
D
C
B
A
TOILET
1
STEEL DECK
TRIM SUBSTANCE
A-A ( 1 : 4 )
70mm X M10mm
FIXING BOLT*
BASE PLATE
M10
NUT AND WASHER*
NB! To be mounted in the same angle as the surface on the toilet
MIN: 50mm Max: 60mm, �5,5mm,
2
2
3
3
Ca.15
4
WWW.JETS.NO
N-6069 HAREID Tel. +47 70 03 91 00 Fax. +47 70 03 91 01 E.Mail [email protected]
MINIMUM 100mm FROM WALL
STEEL DECK
WALL
BE DRILLED ON SITE
HOLE FOR TOILET, TO
BASE PLATE
TOILET
4
5
DECK (M=1:7,5)
-
Part no.:
Title
Rev.
5
Material:
Weight:
BASE PLATE / TOILET JETS50 INSTALLATION ON FLOOR
Description
32506-063.idw 6
Drawing no
%
Checked by Scale
Sign
Rev.
23.06.2004 RoL
Date
03.06.2005 ToG 23.06.2004 RoL
Changed text of and figure of Wood screws Original Drawing
B
Designed by
60
6
A
* NOT JETS DELIVERY
TM
145
M10 FIXING BOLT
235 �2
RECOMENDED BOLT FIXING ON
1
�1
235 �2
ON DECK (M=1:7,5)
FIXING THE BASE PLATE
RECOMENDED DRILL FOR
130 �2
130 �2
1 WOOD SCREW OR SIMILAR*
D
C
B
A
Installation Instructions
34
Installation Instructions
36
INSTRUCTION MANUAL
Part 2: Operation & Maintenance Vacuumarator Jets 15MB-D
Front Page Contents Page Technical Information; Principle & Function 2104 Principle and Function ................................................................................................................1 2106 Mode of Operation......................................................................................................................2 2142 Vacuumarator Jets 15MB-D .......................................................................................................3 3120 El.motor MEZ 7AA 90L-02..........................................................................................................5 Data Sheet Vacuum Gauge.................................................................................................................6 Operating Instructions 3106 Operation...................................................................................................................................7 3105 Control Cabinet ..........................................................................................................................8 41021 Vacuum Comparison ................................................................................................................9 Maintenance & Repair 2123 Maintenance Schedule ...............................................................................................................10 2166 Troubleshooting & Repair Jets 15MB-D .....................................................................................11 2154 Disassembly Jets 15MB 15MB-D ...............................................................................................12 Drawings 31739-029 Jets 15MB/Jets 15MB-D Part Drawing vacuumarator.......................................................14 31754-031 El Motor MEZ 7AA 90S 02 Part Drawing For Jets 15MB ..................................................15 Spare Parts Information Jets 15MB-D with Dwg Nos.................................................................................................................16
Technical Information; Principle & Function DATA SHEET NO.
Jets Vacuum System: Principle & Function 2104 ISSUE C
Principle
Jets Vacuum System uses differential air pressure (vacuum) for the transport of sewage from the toilets to the vacuum generating unit (Jets Vacuumarator). From the Vacuumarator the sewage is pumped either to a holding tank or to a sewage vacuum treatment plant (STP). A NR-valve (Non-Return Valve) mounted on the vacuum side of the Vacuumarator, separates the vacuum side from the atmospheric side of the system. Start and stop is controlled by a pressure switch, starting the vacuumarator at appr. 40% vacuum and stopping it at appr. 55 % vacuum. See Data Sheet 3103.
Function
Each toilet is connected to the discharge pipes via the Jets valve. The valve is open only during the discharge cycle. One or more vacuumarators keep the discharge pipes under vacuum. Start and stop of the vacuumarator is controlled by a pressure switch. A non- return valve incorporated in the vacuumarator closes off the connection to the mains when the vacuumarator comes to a stop. When a toilet is operated, the Jets Vacuum interface valve is activated. Sewage, waste water and air are sucked into the vacuum mains and transported to the vacuumarator. The macerator integrated in the vacuumarator finally pulps the sewage while pumping it to a holding tank or a sewage treatment plant (STP).
JETS VACUUM AS P.O.Box 14 N-6069 Hareid, Norway Tel.: +47 70 03 91 00 Fax: +47 70 03 91 01 E-mail: [email protected]
1
Technical Information; Principle & Function
Jets Vacuumarator
DATA SHEET NO.
2106 ISSUE G
Mode of Operation The Jets Vacuumarator's main function is to create vacuum in the piping system.The Vacuumarator is a screw pump with liquid ring seal. The principle of operation is a helical rotor running in a cylindrical housing, which together with two end plates forms the pump body. When the Vacuumarator is filled with liquid and started, a liquid ring is created round the rotor. The depth of the liquid ring is governed by the size of the opening in the end plate on the pressure side. This opening is arranged so that the created liquid ring will be touching the rotor hub on one side and the rotor tips on the other. This arrangement creates a series of progressive crescent shaped cavities travelling from suction to pressure side. Air, sewage and water is pulled into those cavities and transported through the vacuumarator.
↑
Suction (Inlet)
↓
The sewage is macerated by the integrated macerator before it enters the pump body. The macerator consists of one rotating knife fixed to the shaft and one stationary knife fixed to the suction chamber. In order to provide sufficient sealing liquid at the time when the Vacuumarator is starting, and thus securing the initial priming of the screw pump, a tank for sealing liquid is mounted on the outlet pipe of the Vacuumarator. This is done for all types of Vacuumarator except for the Vacuumarator Jets 15MB/ 15MB-D, where the 50mm pipe on the outlet pipe functions as a tank for sealing liquid.
Discharge (Outlet)/ Sealing liquid
Pump Housing Macerator
Liquid ring
Rotor
JETS VACUUM AS P.O.Box 14 N-6069 Hareid, Norway Tel.: +47 70 03 91 00 Fax: +47 70 03 91 01 E-mail: [email protected]
2
Technical Information; Principle & Function
Vacuumarator JETS 15MB-D
DATA SHEET NO
2142
ISSUE H
The patented Jets Vacuumarator - creates vacuum - macerates sewage - pumps sewage Designed for direct connection to any kind of sewage treatment plant Outlet can also be connected to gravity piping or holding tank Technical Data: Capacity: Flushing Capacity at 50Hz: Flushing Capacity at 60Hz: Outside Dimensions: Electric Motor: Pump Casing Material Rotor Housing Material Pump Rotor Material: Pump Knives Material: Pump Shaft Material: Connection Inlet: Connection Outlet: Total Weight:
15m3/hr 120 flushes/hr 150 flushes/hr 214 x 554 x 332 mm. (W x L x H) (with compensator) MEZ 7AA 90L-02 Bronze RG5 Stainless Steel AISI 316 Bronze RG10 Stainless Steel AISI 316 Stainless Steel AISI 316 Ø 50 Ø 50 37,6 kg
Part No. Jets 15MB-D Voltage/Frequency 230-380/50, 255-440/60
Part No. 029015001
690/60 690/50 208/60 415/50
029015004 029015005 029015006 029015007
Note: Changes without prior notice
3
Technical Information; Principle & Function DATA SHEET NO
Vacuumarator JETS 15MB-D
2142
ISSUE H
Dimensions 15MB-D
Operating Data
Operating Data 60Hz 50Hz Speed (nom.)...........................................2.880 RPM....................3.480 RPM Power Connections (nom.) ......................220 V/380V...................255 V/440 V Power Output (nom.)...............................2,2 kW...........................2,55 kW Current Consumption (220V) ..................8,3 A Current Consumption (380V) ..................4,8 A Current Consumption (255V) .................................. .....................8,1 A Current Consumption (440V)) ................................. .....................4,7 A Power Factor (nom.)................................0,85...............................0,86 For other Voltages:................................. See Data Sheet No. 3120
! "
! "
!
!
!
!
! "
! "
JETS VACUUM AS P.O. Box 14 N-6069 Hareid, Norway Tel: +47 70 03 91 00 Fax: +47 70 03 91 01 E-mail: [email protected]
4
Technical Information; Principle & Function
El.motor for JETS 15MB-D
DATA SHEET NO
3120 ISSUE E
Dimensions MEZ 7AA 90L-02
All dimensions in mm
Technical data:
Type: Outside dimensions: Number of poles: Mounting: Frame size: Enclosure: Insulation class: Material, housing and feet: Material, fan cover: Material, ventilator: Terminal box: Cable conduit: Cooling: Total weight:
7AA 90L-02 214 x 422 x 228mm (W x L x H) 2 Special flange (IEC-72-1) 90 IP 55 F Aluminium Aluminium Fibre-glass plastic Top mounted, turnable in 90o Threaded holes for 1 x M16 + 1 x M25 TEF 19,6 kg
Operating Data Voltage (V) ................. 208 ................ 230 .............. Frequence (Hz) ......... 60 ................. 50 ............... Speed (Rpm) ............ 3.465 ............ 2.871 ........... Power (kW) ............... 2,55 .............. 2,2 ............... Main current (Amp) .... 10,1 .............. 8,1 ............... Efficiency (%) ............. 82 ................. 81 ............... Duty ......................... S1 ................. S1 ............... j .................................. 0,86 .............. 0,85 ............. Connection ............... D .................. D ................. Part. no. .................... 031151110 ...... 031151100 ....
400 ............ 415 .............. 440 .............. 460 .............. 690 ............... 690 50 .............. 50 ............... 60 ............... 60 ............... 50 ................ 60 2.871 ......... 2.800 .......... 3.465 .......... 3.480 .......... 2.871 ........... 3.465 2,2 ............. 2,2 .............. 2,55 ............ 2,55 ............ 2,2 ............... 2,55 4,6 ............. 4,6 .............. 4,75 ............ 4,6 ............... 2,7 ............... 3 81 .............. 80 ............... 82 ............... 80 ............... 81 ................ 82 S1 .............. S1 ............... S1 ............... S1 ............... S1 ................ S1 0,85 ........... 0,85 ............ 0,86 ............ 0,86 ............ 0,85 ............. 0,86 Y................ Y ................. Y ................. Y.................. Y .................. Y 031151100 ... 031151140 .... 031151100 .... 031151140 .... 031151120 ..... 031151130
Note: Changes without prior notice
JETS VACUUM AS
P.O.Box 14 N-6069 Hareid, Norway Tel.: +47 70 03 91 00 Fax: +47 70 03 91 01 E-mail: [email protected]
5
Technical Information; Principle & Function
!" # $ %
' '
( +
* ,
2 3 2 3#
0 .
2 /
% $ 22!*,(#.* 567 ;)%
)* ), )0 ). )4 )8 )9 *
4 8 9 ) *
$' 5 ' $A BA A ?
=#.>: 8 & & & *14C
&
' -! ! 3 2 ::