Summary • Gen2 Regen ≤1000kg,1.75m/s configuration upgrade – – – –
•
Controller and drive upgrade to ACD2 MRL E&I panel change to mini size Introduce OTIS PM door operator NGSOK as Standard door operator Layout changes accordingly
Gen2 Regen extended to 2000kg, 1.75m/s – Added Regen function to 1150~2000kg as standard – Introduced Otis optimized Gen2 machine – Introduced OTIS E3 qualified HN6000 progressive safety – Other configuration (Controller& drive, E&I panel, door operator) as per Gen2 Regen ≤1000kg
• Gen2 (1150~2000kg up to 1.75m/s,Non-regen) completely phase out Note: Gen2 Regen up to 2000kg is officially sales release on April 1st 2010 and Gen2 sales phase out at the same time
Configuration Upgrade Gen2 Regen ≤1000kg configuration upgrade Gen2 Regen extended to 2000kg to replace GeN2
Machine Upgrade
GeN2
GeN2-Regen
ABA20220AS
ABA20220BD Apply to 1150kg to 2000kg Gen2 Regen only - OTIS optimized Gen2 Machine from the same supplier as GeN2 - Noise and vibration performance is improved - Otis Optimized Gen2 machine for ≤1000kg will be introduced later once it’s available
Controller Upgrade
GeN2-Regen
GeN2 &Previous Gen2 Regen up to 1000kg -OTIS global new controller for MRL product -More compact - OH-CONB604B MRL will be phase out
OH-CON4424 (For GeN2) OH-CONB604MRL(for previous Gen 2 Regen up to 1000kg)
ACD2-MRL Controller Apply to 630kg to 2000kg Gen2 Regen
Regen function is added GeN2 &Previous Gen2 Regen up to 1000kg
GeN2-Regen
-OTIS global integrated regen drive for MRL - More compact - OH-CONB604B MRL will be phase out Non-Regen drive(OH-CON4424) Otis Regen drive for previous Gen2 Regen up to 1000kg
ACD2 MRL regen drive Apply to 630kg to 2000kg Gen2 Regen
E&I PANEL Upgrade
GeN2 & Previous Gen2 Regen up to 1000kg
GeN2-Regen
Min E&I PANEL Apply to 630kg to 2000kg Gen2 Regen
Door Operator upgrade
GeN2
GeN2-Regen
&Previous Gen2 Regen up to 1000kg
Apply to 630kg to 2000kg Gen2 Regen STD: AT120
STD: NGSOK - NGSOK is OTIS global PM operator - DO2000 is still optional
Safety Gear Upgrade
GeN2
STD:9672D/E
GeN2-Regen
STD:HN6000B/C
Apply to 1150kg to 2000kg only
- HN6000B/C are OTIS global E3 safety components - Bigger running clearance. Ride quality is improved and false tripping is eliminated - 9672D/E are still optional
Layout Changes
New Controller & Drive Architecture Previous Gen2 Regen
GeN2-Regen
(OH-CONB604MRL controller)
(ACD2 MRL)
GeN2(OH-CON4424 Controller)
kg 0 0 20 ~ g k 0 3 6
New arrangement is easier for controller and drive inspection
E&I PANEL cutout size
GeN2
GeN2-Regen Apply to 630kg to 2000kg Gen2 Regen
Top floor Min E&I PANEL size reduced, the cutout 1600(H)x250(W).
New Bracket Spacing for top floor Gen2-Regen
GeN2
Apply to 630kg to 2000kg Gen2 Regen Top floor brackets -Stronger rail bracket made machine more stable - Noise and vibration is improved
Back up
ACD2 MRL Introduction
PRODUCT DESCRIPTION Integrated Regen controller Improve aesthetics and performance OTIS WWE (World Wide Engineering) lead design OTIS global source and SSI management
Drive
E&I Panel 210W x 540H x 90D
Controller 320W x1300H x 160D
Duty Table
Controller Operational Parameters Feature
Values
Feature
Values
Baseline Product
GCS -EN
Max Speed (m /s)
1.75
Operation Control
Max 8 Car Group
Max Duty (kg)
2000
Maximum # of Stops
24
Maximum # of Opening
32
Drive Door
OVFR2B-402,403,404, OVFR1A-406 NGSOK/AT120/AT400 /DO2000
LWD
Analog LWD
Service Tool
OTIS SVT
Machine
Opt. GeN2
Rescue operation
MRO*
Position Reference Photo-sensor 75 Max Rise (m)
Note: MRO function is standard. ARO function should be offered as an optional function after June 2010.
Performance Parameter
Target
Min. Floor Distance (mm)
350 @ 1.0m/s 500 @ 1.5m/s ~1.75m/s
Max Floor Distance (m)
11
Maximum Acceleration (PMT measurement: m/s2)