D

Main Power Supply

1

2

3

4

Main Power Switch (By others)

LB LC

6

8

7

Main Power Switch in M.R.

EPS (optional)

K LA

5

LA1

L1

LB1

L3

EPS13

V1

L2

S

4

W1

L3

T

D

PT

KMCMain Contactor 2 1

U1

L1

R

L2

LC1

Q

6

R

KDY Running Contactor 1 2

U

YASKAWA

3

S

5

Inverter

T

U3

V

3

4

V3

W

5

6

W3

H1000 N N PE

141

1



PE

Phase relay short-cricuit signal 2

116

3

GND2

4

YJ

TB2 IP

FR2000-STB

EPS action signal

IG

J7-1

Y10 Up running

J7-2

Y11 Down running

S2

J7-3

Y12 Release

S8

J7-7

COM4

SC

J2-2

X11

MB

FE

J2-10

X19

M1 MC

B1

M2

B2

C

Main control board

J3-7

J7-9

S1

GND2

VS

A+

+12V 0V A

TB1

B+

B

BC

A1

Connect when there is a brake unit

31 KLZ

J7-10

GND3

J8-1

32

PG

A-

(+3)

AC

+

+0

BU

RZD

CDBR-4030

IP (-)

J8-2

IG

J8-5

AO

J8-6

IG TB2 BO

B

Braking resistor

-0

≧37KW Inverter input power

3

4

S3

B

SC

IG

Note: when lift has EPS, it should be connected in the main power circuit in serial as above.

A

A

Design Check Approve

Main circuit

Date

TRA110 Draw No. 17 Sheets 1A Sheet Remark H1000+Asynchronous motor

FUJI YIDA 1

2

3

4

5

6

7

8

1

Main Power Supply

D

2

LB

LB1

LC

LC1

5

6

8

7

Main Power Switch in M.R.

EPS (Optional)

K LA1

4

D

Main Power Switch (By others)

LA

3

L1 L2 L3

Q R S

EPS13

T

PT

KMC Main Contactor 1 2

L1

U1

L2

V1

4

L3

W1

6

R

U

3

S

V

5

T

W

N N



PE PE

FUJI LIFT Inverter

141

1 2

116

3

GND2

4

YJ

Running contactor

Phase relay short-cricuit signal

+OPC-LM1-PR

KDY L1

T1

U3

L2

T2

V3

L3

T3

W3

KDY Built-in Not applicable when there is an ELD

FR-2000-STB Encoder

PR1卡

EPS action signal

Control mainboard

C

J7-1

Y10 Up running

FWD

J7-2

Y11 Down running

REV

J7-3

Y12

J7-7

Release

CN2

CN3

EN

COM4

CM

5V GND A- A+ B- B+ CC+ DD+

[P0] [CM] [PA-] [PA+] [PB-] [PB+] [PC-] [PC+] [PD-] [PD+] [CM]

C

PG

Shielded J2-2

X11

30B

J2-10

X19

Y1

J3-7

GND2

30C

J7-8

VB

J7-9

VS

CMY 12 V2

31

J7-10 GND3

32

KLZ

11

P

P+

Brake Resistor

CM

B

A+

J8-7

A-

J8-8

B+

J8-9

B-

J8-10

B

RZD 3 4 1

DB

DB CN4

2

★ Note: when lift has EPS, it should be connected in the main power circuit in serial as above.

A

A

Design Check Approve

Main control circuit

Date

TRA110 Draw No. 17 Sheets Sheet 1F Remark FUJI + synchronous motor

FUJI YIDA 1

2

3

4

5

6

7

8

1

2

3

U1

V1

4

5

6

8

7

W1

13

ZDY

14

ZDY D

5

B5

N Main power inter-action

9

D

B6

Phase Relay KXX Controller Power Breaker

F13P6A)

S2

T2

TC1 C

F4(1P4A)

Control power transformer

380V 0VAC

F3(1P4A)

J5-4

J5-3

200

X23-

X23+

KJT

A1

A1

116 SMJ

SM1

SM2

SM3

Landing door on 2nd floor

SMn

SMn-1

Braking contactor

KMB 2

1

Connect when floor number≥16

KLZ 2

KJR 1

2

Braking contactor

BK1

1

LZ

RJ

102(-)

BK2

Brake

KLZ

C

3

4

RLZ

D1

Applicable when brake voltage is DC110V 100a

F2(1P4A) Control power breaker

KXX Phase sequence

Main control contactor

KMC 44 43

100

Safety circuit 141 Landing door on N floor

118

SDT

Running contactor

Door lock relay

KDY 44 43

Braking contactor

KMB 1

Connect when total floor number≥16

KLZ 2

2

KLZ 1

4

AC

110

115

GJ

BK1

Brake

LZ

B

BK2

★Braking input power ★

SKT Emergency stop in pit

Emergency running Inspection

ZL1 +

106

DJ

AC

Braking economic resistor

SDC Emergency stop in car

SPS Jigger handwheel switch

3

N

RJ

105 115a

Braking contactor

KJR 2

1

T2 Emergency stop on car top

SJT Emergency stop in M.R.

SMn-2

Remark: The brake voltage is according to the actual. When brake voltage is DC220V, rectifier "ZL1" is connected. When brake voltage is AC220V, jump the "ZL1".

SCS Up running overspeed switch

Door interlock loop

Landing door on 1st floor

B

o b n i a X22+ J5-1 m o T

Car door switch

117

KDY 44 43

d

A2

KMB

Running contactor Door lock relay

110VAC

r X22- J5-2 a

101 A2

KMC 44 43

Braking economic resistor

FR-2000-STB

FR-2000-STB

200a

201

110VDC

220VAC

d r a o b n i a M o T

0VAC

Main control contactor

103(+)

Remark

R2

114a SKS Rope break-off switch

Applicable when brake voltage is AC220/DC220V

SXS Speed governor switch 111 114 SNQ Safety gear switch SSJ Top final limit

A

Design Check Approve

108

113

SXJ Bottom final limit SHC Buffer switch

Safety, Door Interlock, Brake Circuit

Date

109

TRA110 17 2

Draw No. Sheets Sheet Remark

FUJI YIDA 1

2

3

4

5

6

7

8

A

1

2

L31

3

4

5

6

8

7

N

D

D

UPS AC220V

501

502

F6

Emergency Relay

503

504

Traction Machine Lighting

ELY

KYJ

Emergency Relay

Brake Release Button

SZ2

1

2

4

KYJ

505

3

Monitor Breaker(1P4A) Machine Monitor SocketXJC

F4(1P4A)

T2 +

XTC

KDY 43

Door Lock Relay

Brake Contactor

KMB 1

2

Brake Contactor

To be connected when floor number≥16

KLZ 2

KJR

BK1

2

1

1

LZ

Brake

BK2

KLZ 3

4

A2 A1 KYJ SZ1 Brake Release Button

D1 RLZ Brake Resistor

DC48V

AC220V

Emergency Contactor Electric Operation GJ

Run Contactor

44

RJ Power Unit TC2

Indicator Socket

Main Contactor

103(+) KMC 44 43

To be connected when traction machine doesn't have braking discharge circuit

N

DC48V Brake

102(-)

-

C

C

AC220V Power Unit TC3

+

-

DC48V

Note: Re-connect input power from T2 to 200,N to 201 when brake voltage AC220V/DC220V with EPS.

504

505 Applicable for MRL lift with UPS brake release device

F4(1P4A)

T2

B

+

Main Contactor

103(+) KMC 44 43

Run Contactor

44

KDY 43

Door Lock Relay

Brake Cotactor

KMB 1

To be connected when floor number≥16

KLZ 2

2

KJR 1

2

1

Brake Contactor

BK1

Brake

LZ

BK2

KLZ 4

B

3

D1 RLZ Brake Resistor

DC48V

AC220V

Power Unit TC2

RJ

N -

To be connected when traction machine doesn't have braking discharge circuit

DC48V Brake

102(-)

Applicable for MRL lift with DC48VEMK brake release device

Note: Re-connect input power from T2 to 200,N to 201 when brake voltage AC220V/DC220V with EPS.

A

Qian Jianqiang Design 48V Brake & Brake Check Release Circuit Approve

Date

1

2

3

4

5

6

2013.10.1

7

Draw No. TRA110 12 Sheets Sheet 2A Remark

8

A

1 Inspection box oncar top

3

DMGCOM in Car Top

130

Top terminal 2 Bottom terminal 2Top limitBottom limitTop terminal 1

SDZ2

XDZ2

SXV

Emergency running

L

D

GJ

N

Up door zone Down limit zone

KJT

Slow up in M.R. Slow down in M.R.

MS

J3-10

X0

J3-7、8、9

KMB Door interlock

43

121

122

123

124

X4

X5

X6

X7

X8

XF

Brake

KLZ 31

43

KDY

Electronic lock Locked when Break-off

Red SDF

DF

WK

X20

X21

Black

32

KBK

D

YJ

Slow down at car top

X3

X2

J1-2

120

KBK1 KBK2

44

+24V

Slow up at car top

MX

X1

J1-1

119

DMS DMX

FMS FMX

J4-4 J4-3 J4-2 J4-1

44

1

3

GND2

5

SMQ XMQ

2

+24V

6

Emergency stop contactor

FMG COM in M.R.

Switch power +5V -5V +24V-24V

+5VGND3 +24VGND3

Fire fighting motion

SMQ XMQ SXF CXF XXV SDZ1 Bottom XDZ1 Fireman switch limit 1

Brake detecting switch

DJ

J1-3

J1-4

FR2000-STB

J1-5

J1-6

J1-7

J1-8

X9

X10

J1-9 J1-10

X13

X12

J2-1

J2-3

X14

J2-4

X15

J2-5

X16 X17

J2-6

J2-9

J3-1 J3-2

J2-8

J2-7

Emergency Running Signal

For elevator speed≥2.0m/s 2

8

7

Opional

6

WK

5 Connect when there is fire fighting function Fire fighting center

Thermal controller constant-close output

4

FAR

3

201

For lift with 6 stop above

2

200

Fan: DC24V

1

For rear door

21

Running contator

1

KJR

KDY A2

Y8

A1

A2

KYJ

Y2

Y4 Y5

Y3

COM1

Y1

2H 2L

J4-6 J4-7 1H

1L

4

KJT

A2

3

LD2

Connect when there is fire fighting function

KMB

CM1

5

C

X22+ X22- X23+ X23LD1

22 6

KM2 GM2

24T

KM GM

CB+ CB-

GND1 C+ C-

116 101 118 101 Safety Detecting Door Lock Detecting

GND1

Call box/COP Twin control/Group control communication wire communication wire

Connect when total floor number≥16

101

116

J4-9 J4-10

J4-5 J4-8

J5-10

J5-9

A1

KMC A2

J6-3 J6-4

J5-4

KLZ Braking contactor

2

KJT

C

Y7

A1

J6-1 J6-2

J5-3

Y9

A1

Economic resistor relay

COM3

COM2

J5-2

Y6

J6-5

J6-8

J6-7

J5-1

J6-9

Main control contactor

J6-6

J6-10

When using Blue Light SJT-FZ,leave them For rear door

For rear door

RS-485 Serial weighing communication

24T GND1 C+ C-

1KAB2

Safety edge1

B

KQZ KKZ KCZ

KMZ

GMV2 KMV2

GMV1 KMV1

SZS

SZY

RT- RT+ 24V CMM

SZH

1KAB1

B

2KAB1

Safety edge1

CMM

QZ

J9-1

J1-1J1-2 J1-3J1-4

Spcial use switch Bypass switch By attendant switch

Safety edge 2

Door close limit 1Door open limit 1

Light loadNo load Overload Full loadDoor close limit2Door open limit 2

2KAB2 Safety edge2

KZ

J9-8

J9-9

CZ

GMV2 KMV2

MZ

J9-5

J9-6

GMV1 KMV1

J10-6 J10-5

J9-3

KAB

J9-2

KAB2

J9-4

J9-7

J10-1

J10-2

J9-10

J4-4 J4-3

J4-2

J10-7 J10-8 J10-9 J10-10

NCZB J11-1

BLV+ red

A

J11-2

J11-3

BL1 BEL

J11-4

J11-7 J11-8

J11-5 J11-6

DC24V

J3-4 J3-3

J3-2

J3-1

J4-1

J5-4 J5-3 J5-2

14

N

24V CMM

L31

BY1

+24V Door open button2

J5-1

J6-4 J6-3 J6-2 J6-1

GMD1 Door close light

+24V

SKY

SGM2

KMD2

GMD2

Door open light 2

Door close light 2

Design Check Approve

KYD

BY2

Control circuit

Date

3

4

5

TRA110 17 3

Draw No. Sheets Sheet Remark

FUJI YIDA

Door open holding light

Spare output 2

+24V

Door open holding button

Door close button 2

SKM2

SGM1 KMD1

BLV-

+24V Door close button

SKM1

Door open light

TC1 1

J2-1

+24V Door open button

CZD

KZM

Arrival chime

+

J2-2

ZM 13 Light control Overload light

yellow

F5(1P4A) black

J2-4 J2-3

6

7

8

A

1

2

201

3

For machine room less elevator

D

200

FXS

4

5

U

U5

V

V5

W

W5

6

L31

N

Door motor

SDM

N

201

Pit light switch

SKK Pit lighting socket

NCZB COP mainboard

B2

KMV1(5)

J9-2

B3

GMV1(6)

J9-3

CMM(4)

J9-1

2

GM(3)

1

KM(2)

Speed governor reset

EKM

Pit light

L312

C2 C3

Speed governor motion

XD

Car top socket

200

Shenling VF Door machine XS2

EDM

Car top light

L311

L

XK

XG Control cabinet power socket KZM 21

Car light

SJM1

L33

22

EM

EM1

Car light switch

Car light

Lighting control relay

EM2

Car fan switch

SFA

Car fan

FA

FAN

8

C

D

Car top light switch

PE

XS1

8

7

C

CM1(1)

8

The No. in paranthesis is cable No. of Shenling door machine

Shaft light switch(M.R.)

U

U6

V

V6

W

W6

2

N

SZMk 1

2

1

ECM1 Shaft light

Door motor 2

L

200

N

201

PE

3

2

3

ECMn

Safe lighting breaker

TD3200 VF Door machine

B

Shaft light switch(pit )

SZMf

L32

Q1

NCZB

PC1 PC2 PAC

KMV2

J10-5

GMV2

J10-6

CMM

J9-1

L3

L31

N

N

Q2

GM2

CD

B

L32 KM2

OD

N CM1

COM

Shaft lighting breaker

A

A

Design Check Approve

Control circuit

Date

Draw No. Sheets Sheet Remark

TRA110 17 4

FUJI YIDA 1

2

3

4

5

6

7

8

1

2

3

4

5

6

8

7

24T GND1 C+ C-

D

4

3

2

BEL Text Text

N floor down call

N-1floor up call

N-2 floor up call

3rd floor up call

3rd floor down call 2nd floor up call

Elevator A CB+

CB+

6

7

CB-

CB-

7

8

GND1

GND1

8

J4 6

BL-2000-STB

2nd floor down call

Arrival lantern

1st floor up call

Elevator B J4

1

2 Arrival gong output (negtive motivation)

3 -24V

+24V

4

DZZ

DZD 1

2

3

4 Up

C

Down

+24V

1

J2 2 +24V

3

4

1

2

3

+24V

4

J3

NHTB

J1

1

4

3

2 1

J2 2

3

+24V

4

1

2

3

+24V

4

J3

NHTB

J1

1

4

3

2 1

+24V

2

J2 3

4

1

2

3

+24V

4

J3

NHTB

J1

1

4

3

2 1

2 +24V

4

1

3

J2

NHTB

J1

1

4

3

2

J1 2 +24V

3

4

J3

NHTB

1

D

C

Arrival gong

Indicator

BL-2000-STB

J4

Full load

J4

Inspection

8

10 V+ V- E

C+

24T

9

B

1

1

2 3

4

1 4

J1 J2

3

4 3

Up call +24V

2

2

1

1

4

4

2

D C B A S X CZ MZ XF JX

C-

5

GND1

10 C-

24T

Text B

8 9 GND1 C+

5

3

4

2

6

7

8

9 10 11 12 14 15 16 17 J5

BL2000-HXJ-V9

J3

J2

J1 J1

J2

Converter board

NHTB

NHTB J3 A

3 2

3

Down call

+24V

J3

2

1

1

Design Check Approve

Landing call loop

Date

2

3

4

5

TRA110 17 5

FUJI YIDA

When two elevator are twin controled and use one common landing call button ,connect the wire as per this drawing and only connect the parallel wires. 1

Draw No. Sheets Sheet Remark

6

7

8

A

1

2

3

4

5

6

8

7

Indicator D

D

Overload Fireman

SN9

J12 D C B A S

X CZ MZ XF JX

SN1

4

>

V+ V- E

4

>

3

1st floor car call

ND1

+24V

J1

JE1

3

9th floor car call

+24V

2

JN1

ND9

2

1

1 1

2

6

7

8

NEB

9 10 11 12 14 15 16 17 J5

BL2000-HXJ-V9

GND1

24T

2

SN16 4

Converter Board

1

4

3

2nd floor car call

ND2

+24V

3 JN2

JE8 2

2

>

1

24T

5

J2

GND1

8

C+

C-

9

C-

J4 10

4

C+

3

FR2000-STB C

SN2

J1

J3

16th floor car call

+24V

ND16

J2

1

C

NCZB SN3

SN17

4

Optional function 3rd floor car call

3 ND3

+24V

4 JN3

>

2

J1

JE1

3

17th floor car call

+24V

2

ND17

1

1

NEB SN8

SN24

4

8th floor car call

4

3 ND8

+24V

JN8

JE8

2

3

>

J2

24th floor car call

+24V

2

1

ND24 1 B

8

J10 9

RT-

RT+

24V

10

CMM

7

1

2

3

1

4

C-

1

C+

2

J1 FR2000-CZB COP

GND

3

>

4

+24

B

2

3

4

Terminal

J1

Voice announcer

Car indicator

A

Design Check Approve

Weighing

Car call loop

Date

Draw No. TRA110 17 Sheets Sheet 6 Remark

FUJI YIDA 1

2

3

4

5

6

7

8

A

2

0V

J1-3

N

+5V

J1-4

1H

FR-2000-STB

J1-6 J1-7

1H 1L

J4-7

J4-7

GND1

J4-8

CB+

Elevator B

CB-

J4-8

GND1

J1-8

GND1

CB-

GND1

CB+

J4-8

J4-6

1L

J4-7

D

FR-2000-STB

1H

J4-6

1L

Elevator A

8

7

GND1

Elevator H

CB+

L

FR-2000-STB J4-6

6

CB-

N

5

BL2000-QKB

AVR2

(4A) AC220V

D

4

GND1

F7 L1

3

Group control board

1

Group control system loop:

The terminal can be placed near to the control cabinet Suggest that there be no radiation equipment nearby

FR2000-STB

SJT-WJ

SJT-WK 4

+5V

5V

8

GND3

GD

9

C+

H

10

C-

L

C

J4 Wireless remote control system loop:

Monitor center 1 C

DC5V/1.5A

Power

SJT-WJ

Monitor center 2

Wireless network DC5V/1.5A

Power

Control cabinet

FR2000-STB Wire remote control system loop:

3

GND3

3

4

+5V

4

9

C+

9

10

C-

J4

B

BL2000YXZDB J1

SJT-YCJ 6

YH

H

7

YL

L

J1 8

YG

G

Monitor center B

10 Network

(Every control cabinet use one of this)

Control cabinet Power

FR2000-STB IC/ID card management system loop : J4

GND3

3

4

+5V

4

9

C+

9

10

C-

BL2000KIC/KID J1

SJT-QIC/QID 6

YH

H

7

YL

L

J1 8

YG

G

IC card reader MF-500

Monitor center

10

4 C-

GND1

24T A

C+

GC-1 2 3

1

3

Note:one monitor system use one data collector it can monitor several elevators.

Network

(IC/ID card network controller )

ID card reader YX-K4-232

Control cabinet

Design Check Approve

Power 1

2

3

4

J2 BL2000-CIC/CID Car IC/ID controller

Optional function loop

Date

Draw No. Sheets Sheet Remark

TRA110 17 7

FUJI YIDA 1

2

3

4

5

6

7

8

A

1

2

3

4

5

6

7

8

D

D

SJT-ZPC-V2

FR2000-STB JP1-1 J4-2 J3-7 J3-8 J3-9

+24V 12

JP1-2

K10

11

21

GND2

K14

21

44

41

A1

K10 44

D5

C1

A2

K10

41

D2

K12

LS2

ZPX

C

R1

K10 22

JP1-3

Up releveling door zone input

COM1

A2

K12 D1

K12

ZPS

A1

22

K11 12

61

64

LS1

31

JP1-4

32

J5-8

A1

K11 31

Down releveling door zone input

Y0

22

21 11

K12 Advance door opening /releveling door zone switch

Advance door opening /releveling relay output J5-10

K11

C

D3

JP1-5

Y0

A2

K11

32

A1

A2

K14 D2

K12

Advance door opening /releveling relay output signal test J3-3

JP1-6

21

K10

K14 22

34

33

31

K11 32

41

64

51

44

JP1-7 K10

JP1-8

Releveling door zone signal inputJ3-4

K11 51

54

61

64

JP1-9 SMn B

Optional Function: Advance door opening and Releveling

117

SMJ

K12

116 Door Lock JP1-10

11

K14 12

44

K10 43

61

K11 54 B

118 Door Lock JP1-11

SM1

A

A

Qian Jianqiang Design Check Approve

Date

1

2

3

4

5

6

Advanced Door Opening

2013.10.1

7

Draw No. TRA110 17 Sheets Sheet 8 Remark

8

1

2

3

4

5

6

Monitor Room NKT12(1-1)16N--59N(Main) Emergency Power Box Alarm E. Light Intercom

-

+ -

+ -

Car Top

-

+

R L

-

+

Pit

R L

Car

-

+

R L

-

EB1 EB2 +

AL

AD1

+

-

AC AC

AD2

R L

D

A- AR

EYJ

P+

+ -

PR

L31 N

E. Power

+

From main intercom to pit of lift #1 RVVP 0.75*5

JL1

JL+

A- AR

Call

AC220V +

Alarm

D

M.R.

8

7

AD1

AD2

AD1

AD2

Adapter

R L

L

AL

AC220V

A- AR

(Lift 1#)

AL

C

C

M.R.

Car Top

-

+

R L

+

-

Pit

R L

+

-

R L

-

EB1 EB2 +

R L

Call

JL1

JL+

From lift #1 to pit of lift #2 RVVP 0.75*5

Car

EYJ

Alarm

Emergency Power Box Alarm E. Light Intercom AC220V + + + -

A- AR P+

AL

AD1

AD2

+ -

PR

L31 N

Adapter

R L

L

A- AR

(Lift 2#)

AL

AD1

AD2

B

B

From lift #2 to pit of lift #N RVVP 0.75*5

A- AR

Emergency Power Box Alarm E. Light Intercom

+ -

-

+

R L

+

-

Pit

R L

+

Car

-

R L

-

EB1 EB2 +

+ -

R L

JL1

AL

AD1

AD2

Intercom bus cable by others and layout should be reasonable) 1, cable is RVVP 0.75*5

Adapter

R L

Call

JL+

+ -

Car Top

EYJ

Alarm

AC220V +

M.R.

2, single bus should not bifurcation or star wiring 3, Intercom should be connected to its own adapter.

A- AR

AL

AD1

AD2

P+ A

PL31 N

L

Date

(Lift N#)

1

2

A

Qian Jianqiang Design Optional Function Check Approve

R

3

4

5

6

2013.10.1

Draw No. TRA110 17 Sheets Sheet 9 NKT12 Intercom(bus connection) Remark

7

8

1

2

3

4

5

6

Monitor Room

Emergency Power Box

M.R.

Alarm E. Light Intercom AC220V +

D

-

+ -

+ -

Car Top

-

+

R L

-

+

Pit

R L

R L

EB1 EB2 +

-

+

-

AC AC

NKT12(1-1)6A--64A(Main)

R L

E. Power

+ Car

-

+

8

7

D

AC220V Call

EYJ

Alarm

E.Power above 32 by own

JL1

JL+

P+ P-

R

L31 N

R1

L

L1

(Lift 1#)

C

C

Emergency Power Box Alarm E. Light Intercom

-

+ -

Car Top

-

+

R L

+

-

Pit

R L

+

Car

-

R L

EB1 EB2 +

-

R L

Call

JL+

M.R.

+ -

EYJ

Alarm

AC220V +

JL1

P+ P-

R

L31 N

R2

L

L2

(Lift 2#)

B

B

Intercom bus cable instruction: 1:Each one connect one communciation cable to monitor room 2:Cable is RVVP 0.75*4 Emergency Power Box Alarm E. Light Intercom AC220V + + + -

M.R.

-

+

Car Top

R L

+

-

Pit

R L

+

Car

-

R L

EB1 EB2 +

-

R L

LN

Call

JL+

EYJ

Alarm

RN

JL1

P+ P-

A

Qian Jianqiang Design Optional Function Check Approve NKT12 Intercom

R

L31 N

L

(Lift N#)

1

2

Date

3

4

5

6

2013.10.1

7

A

Draw No. TRA110 17 Sheets Sheet 10 Remark

8

1

2

Emergency Power Box Alarm E. Light Intercom AC220V + + + -

3

Car Top

M.R.

-

+

R L

4

Pit

R L

5

6

8

7

Car

R L

R L

EB1 EB2

D

EYJ

Alarm

D

E. Power

Call

NBT12Intercom

JL1

JL+

+

+ -

P+ PR

L31 N

AC AC

R1

R2

(Lift 1#)

AC220V

Above 32 by own RN Emergency Power Box Alarm E. Light Intercom

-

+ -

+ -

Car Top

-

+

Pit

R L

R L

R L

JL1

JL+

C

Car

EYJ

Alarm

AC220V +

M.R.

R L

EB1 EB2

Call

C

P+ PR

L31 N

(Lift 2#)

B

B

Intercom bus cable instruction: 1:Each one connect one communciation cable to monitor room Emergency Power Box Alarm E. Light Intercom

+ -

-

+

Pit

R L

R L

2:Cable use twisted-pair,wire diameter 0.75square,2 cores

Car

R L

R L

EB1 EB2

Call

JL+

+ -

Car Top

EYJ

Alarm

AC220V +

M.R.

JL1

P+ P-

A

Design Qian Jianqiang Optional Function Check Approve NBT12Intercom 2013.10.1 Date

R

L31 N

(Lift N#)

1

2

3

4

5

6

7

A

Draw No. TRA110 17 Sheets Sheet 11 Remark

8

1

2

3

4

5

6

8

7

D

D

J4

J5

IC Card Control

IC Card Control

DC12V output J3

JT-2000C

JT-04A1

EPSS-EPB110/220

DC110V output 220V Input J2 Yellow TerminalsJ1

J6

P1

P2

P4

P5

P6

J22

P7 24+ 24-

J1

24+ 24- 1 2

OUT1+ 0UT1-

3 -

J8 4

1 2

3 -

+

4 +

21

Jump it for use

KJT

T2

N

BK1

22

-

+

B5

BK2

B6

116

118

Leveling Zone

SN1

MQ1

SN8 4

4

3

F1 Car Call

When MRL lift has "advance door open" or "releveling" function, this wiring should not done.

Power DC12V

24T GND1

24T GND1

optional

ND1

JN1 2

JN8

3

F8 Car Call

+24V

2

ND8 1

1

C

C

SN2

Video Cable

4 SN9 To monitor machine in shaft

3 2 1

4

J1

J12

JN2

ND2

3

>

LCD indicator in Controller

F2 Car Call

>

JE1 2

+24V

F9 Car Call ND9

1

CZB

Applicable for MRL lift with EMK electric brake release and machine monitor function

SN3 4 3

F3 Car Call

ND3

+24V

JN3

2

Note: when JT-2000C is applied,the connection of wire 3 &4 between . extension card and IC card controller should be reverse When JT-04A1 is applied, instruction on CZB board should be connected to OUT1,instruction on extension board should be connected to OUT2.

1

B

B

SN4 4

AC220V +

-

+ -

3

F4 Car Call

Emergency Power Box Alarm E.Light Intercom

M.R.

+ -

-

+

Car Top

R L

Pit

R L

Guard Room

R L

+

-

R L

ND4

Car Inside

+24V

JN4 2 1

Red BlackYellowBlue

Call

EYJ

Alarm

14 BJ 13 JL+

JL1

P+ PR

L31 N B5 A

BJ 5

9

B6 Remark:BJ (inter-action for alarm is optional)

(Jingke 5-party intercom) A

Design Qian Jianqiang Opional Function Check Intercom,Electric Approve Brake Release 2013.10.1 Date

1

2

3

4

5

6

7

Draw No. TRA110 17 Sheets Sheet 12 Remark

8

1

2

3

4

5

6

8

7

200

Top final limit switch

D

SSJ D

100

Top limit switch

SSV

Top terminal switch

SSD

Top sub-terminal switch

*1

SSD2

*2 200

Bottom final limit switch Bottom limit switch

SXJ

SXV

C

C

100

Bottom sub-terminal switch

SXD2 *2

Bottom terminal switch

SXD *1

Leveling position

Leveling zone switch

SMQ

XMQ

SMQ

XMQ

H Car

(Unit:mm) Shelter board H1 B

UP

ELevator have to finish hoistway learning before high speed running. The conditions below are neccesary before hoistway learning: 1.Top/bottom limit switch and top/bottom terminal switch are installed ,connection is correct. 2.Up/down leveling zone switch and shelter board are installed ,connection is correct. 3.Safety circuit and door interlock circuit are normal. 4.General parameters and running parameters have been set. 5.Elevator can perform inspection running. 6.If inverter is YASKAWA G7 and above 18.5KW ,please check if the junction of inverter braking unit in the bottom left corner of the control cabinet is on 415V(Open the grey cover). Before hoistway learning, the system should be in inspection state and elevator should press the bottom limit switch.If elevator don't located at the bottom limit position,"To Down Limit"will be displayed Press slow down button as to move the elevator to bottom limit.If elevator is at bottom limit and " Enter To Start" is displayed(Elevator State:Up leveling zone X9 is valid,down leveling zone X10 takes off from shelter board ),press "Enter" key,elevator starts to perform hoistway learning(Elevator state : bottom limit X6 is reset ,then down leveling zone X10 come into the leveling zone).Hoistway learning stops at top limit (Elevator state:when arriving the top floor , up leveling zone X9 takes off from shelter board ,then top limit switch act )."Success" will be displayed if hoistway leaning is finished successfully.Please strictly perform hoistway learning according to the steps above ,otherwise hoistway learning may fail."Failure LER=#" will be displayed if there is a fault,you should solve the problem by fault code at first. If you want to escape from hoistway learning ,press "Esc" key,then "LER=15" displayed.

A

B

DOWN

Speed

0.5m/s

Item

1.0m/s

1.6m/s

2.0m/s

2.5m/s

230

2500 4000 230

2500 6250 230

250

250

250

*1 *2 H

1000

1300

2500

180

180

H1

200

200

Design Check Approve

Signal collection system

Date

Draw No. TRA110 17 Sheets Sheet 13 Remark

FUJI YIDA 1

2

3

4

5

6

7

8

A

1

2

3

4

Control cabinet GC-1

D

Terminal

CB5

XDZ No.

Mark

1

L31

D

Car top inspection box

Car top junction box

1

24T

1

2

GND1

2

C+

3

C-

4

122

5

L33

5

105

5

110

116

6

6

L313

6

111

7

7

EM

7

8

FA

8

9

CMM

9

KMV1

10

6 7 8

117

Door interlock

9

118

8

10

100

9

114

Safety

DC-9 DC-10

200

10

201

10

11

100

11

GMV1

11

12

106

12 KAB

12

13

108 110

13

BL1

13

14

14

CZ

14

15

15

DF

16

B1

15

111

17

B2

16

18

B3

Electronic lock

DC-11

15

116

MZ 16 +24V

16

17

117

17

KMV2

17

19

18

GND2

18

GMV2

18

20

19

GND2

19

KAB2

19

Brake detection

20

130

20

Temperature Detection

21

MS

20 CM1 21 KM2 22 GM2

23 B1 24 B2 25 B3

Intercom

21 BKB 22 WK 23 BK1

Brake

24 BK2 25 201 26 XS1

Optional

MX

23

SMQ

24

XMQ

25 BLV26 BLV+

For machine room less and two direction speed governor

27 XS2

22

27

ZM 28 CM1

28 GND1 29 CB+ twin control 30 CB-

NKB24A

DC24V

B4

26

1 DMS 2

2

116 117

3

200

4

201

5

CMM

6

GMV1

7

KMV1

MX

8

KAB

MS

9

KM

10

GM

11

CM1

12

(E)

1 DJ

DMX

EDM SDM L31

XD

N

SMQ

SMQ

XMQ

XMQ

GND2 111

SNQ

108

SNC

1

117A

2

117

3 4

201

22

5

CMM

23

CMM

6

GMV2

24

EM

25 26

EM2

27

B5

27

FA

28

B6

28

N

30

EM1

FAN

7

KMV2

8

KAB2

9

KM2

Mark Remark

1 2 CMM

200

KCZ

30

C

WECO light curtain connection No.

107

KMZ

30 GM

U1 V1 W1 N U3 V3 W3

CB8

CZ

29

Mark

1 2 3 4 5 6 7 8 9 10

Door operator cable1

MZ

29 KM

DDZ No.

13

21

29

Power terminal

TB7

3 GND2/

4

Limit

Door operator cable

2

130

3

121

1

105

JL+ JL1

N

GND2

5

12 115a 13 115 14 130 Inspection

B

CB3

4

4

11

CB2

DC-1 DC-2

COP cable CB9

C

DC-3 L31 1 2 L31 N 3

8

7

SDT

N

3

CB5

6

100

L32

2

GC-7 GC-3

GC-2

CB5

GC-4

5

Signal

3 KAB 4

200

5

PE

6

201

Power B

10 GM2 11 CM1

JL1

12 (E) ALARM

13

JL-

Note: when lift has "advance door open" function, B5 should be connected to ZPS, B6 connected to ZPX. When MRL lift has "electric brake release" function, B5, B6 should be connected to level zone switch.

Arrival Gong +24V GND

Leveling Sensor

T1 T2(action) A

Car top circuit

Date

BL1

BLV+ 2

BLV-

Design Check Approve

SMQ/XMQ

GND2 1

+24V

Blue(-) Brown(+) Black(signal)

A

Draw No. TRA110 17 Sheets Sheet 14 Remark

FUJI YIDA 3

4

5

6

7

8

1

2

3

4

5

6

8

7

Control Cabinet

GC-7

Hoistway cable CB3 2 24*0.75+1*2.0mm D

Plug (171830-1) Pin(170308-1)

Control cabinet

GC-7 171364-1

C

Wire No.in

No.

Plug

drawing

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

119 121 123 120 122 124 GND2 108 114 117 118 XF DF

19 20 21

Top terminal 2

Top terminal 1

SDZ1 SDZ2

117 NKTM E

Bottom terminal 2 Bottom limit Bottom terminal 1

Applicable when speed above 2.0m/s nth floor door lock

L

Bottom final limit Top final limit

Fire switch

Earthing Pit emergency stop

GND1

Control cabinet Plug(1-480705-0)

1 2 3 4 5

24T GND1 C+ CE

GC-4 1-480704-0

Cable No. 1 2 3 4 Shield

2F

1st floor door lock Applicable when speed above 2.0m/s

120 GND2

XDZ2

HTB J1 CH-4

124 XDZ1

GND2

Intercom

122 GND2

XXV

108 109 DF

SXJ

1F

1 2 3 4

Plug L31 N Light and socket in pit

B

SXF

GND2

spare

Wire No. in Pin No. drawing

24T GND1 C+ CE

DF

XF

2*2P*0.75 CB2 drawing

V+

2nd floor door lock

GND2

Wire No. in

V-

24Ta

1KTM 118 E

Electronic lock

21 22

OUT:DC24V

3th floor door lock

C

Door interlock

Landing call serial communication cable

Pin No.

Note: when floor/stop number is more than 28, please cut the power cable 24T in the middle and extend another branch cable(length:2m) from the second power unit in shaft , wire no. 24Ta, GND1.

Power Unit

2KTM 1KTM E

24

Plug

N

IN:AC220V

3KTM 2KTM E

23

B

HTB J1 CH-4

SXV

GND2 119 GND2

Top limit

R L

20

SSJ

123

Olivine 19

114 113 121 GND2

E 111 106

D

CB1

Pit

17

GC-4

nF

1 2 3 4 5

Cable No.

L31 N P+ P-

18

200 201

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

109 113 Buffer SHC

E 111106

HTB J1 CH-4

Pit emergency stop SKT and rope breakage switch SKS

CH-4

when lift has through open (double door),HOP wires at the sub-door side should be connected to HOP wires at main door side in parallel .

HOP Power Cable CB1 2*0.75 Dwg No. 200

A

201

Wire No. 1 2

Dwg No. 200 201

Design Check Approve

Note: CB1 is only applied when the floor/stop is more than 28, the cable are with number tube at two ends, length is half shaft height plus 5m.

Hoistway circuit

Date

Draw No. TRA110-B 17 Sheets Sheet 15 Remark

FUJI YIDA 1

2

3

4

5

6

7

8

A

2

3

4

Traveling cable CB5 36*0.75+4 core shield

4

C-

shield 4

C-

4

E

shield

E

24T

shield 1

2

GND1

3

4

C-

shield 4

C-

4

E

shield

E

5

1

CMM

2

GND2

white 2

GND2

2

2

3

130

white 3

130

3

4

MS

white 4

MS

4

5

MX

white 5

MX

5

6

SMQ

white 6

SMQ

6

7

XMQ

white 7

XMQ

7

8

CM1

white 8

CM1

8

DC-2

9

KM

white 9

KM

9

171358-1

GM

white 10

GM

10

Car top

1

Plug(172347-1)Pin (170308-1)

+24V

DC-10

CMM

1

KMV1 white 2

KMV1

2

3

GMV1 white 3

GMV1

3

4

KAB

white 4

KAB

4 5

white 1

5

CZ

white 5

6

MZ

white 6

MZ

6

7

KAB2

white 7

KAB2

7

8

KMV2 white 8

KMV2

8

JC-10

9

GMV2 white 9

GMV2

9

171358-1

10

BLV+

white 10

BLV+

10 11 12

171358-1

11

11

white 11

BL1

BLV+

12

12

N

yellow 8

N

yellow 12

ZM

13

13

ZM

yellow 9

ZM

100

orange 1

100

1

1

2

106

orange 2

106

2

2

3

108

orange 3

108

3

3

B1

white 11

BLV+

white 12

13

ZM

1

JC-11 1-480704

CZ

BL1

12

2

C+

white 1

Plug

1

shield 3

+24V

Car top

24T

shield 2 GND1

C+

1

BLV-

Pin No.

3

5

2

white 13 white 14

B1

4

3

110

orange 4

4

4

white 15

5

111

orange 5

111

5

5

B3

white 16

B3

5

6

116

orange 6

116

6

6

B4

white 17

B4

6

7

117

orange 7

117

7

7

YJ+

white 18

YJ+

7

8

L31

orange 8

L31

8

8

YJ-

white 19

YJ-

8

9

N

orange 9

N

9

9

9

10

10

JC-9

11

11

171364-1

10

L33

orange 10

10

DC-3

11

KM2

yellow 1

KM2

11

171364-1

12

GM2

yellow 2

GM2

12

13

13

yellow 3

200

14

yellow 5

201

15 16

14

200

yellow 4

15

201

Car top

4

B2

DC-9 171364-1

C

13

B2

L33

D

1

white 12

110

Plug(171830-1)Pin(170308-1)

Orange 11、12 earthed

Control cabinet

171364-1

1

Wire No. in drawing

1-480704

5

171358-1

GC-3

Cable No.

Pin No.

Plug(1-480705-0)

3

BLV-

12

12

13

105

yellow 1

105

13

14

106

yellow 2

106

14

15

L33

yellow 3

L33

15

yellow 4

FA

16

B

16

B1

yellow 6

B1

16

FA

17

B2

yellow 7

B2

17

17

EM

yellow 5

EM

17

18

B3

yellow 8

B3

18

18

JL+

yellow 6

JL+

18

19

B4

yellow 9

B4

19

19

JL1

yellow 7

JL1

19

Design Check Approve

20

B5

yellow 10

B5

20

20

20

Date

yellow 11

B6

21

21

21

21

B6

2

8

COP

C+

1-480704

DC-11

Wire No. in drawing

Plug(172347-1)Pin(170308-1)

shield 3

DC-1

Plug(172347-1) Pin(170308-1)

Control cabinet

Plug(172347-1)Pin(170308-1)

GC-2

B

Plug(171830-1) Pin(170308-1)

2

C+

11

1

1

3

10

A

24T

shield 2 GND1

1-480704

5

C

Shield 1

7

COP

GND1

Plug

Plug(1-480705-0)

24T

2

Plug

Plug(1-480705-0)

1

Pin No.

Car top

GC-1

Cable No.

6

COP cable CB9 19*0.75+9*0.75+(2*2p)*0.75

Plug(171830-1)Pin(170308-1)

D

Pin No.

Wire No. in drawing

Orange 11、12 earthed

Plug(1-480705-0)

Plug

Wire No. in drawing

5

Plug(171830-1)Pin(170308-1)

1

3

4

5

A

Traveling cable

Draw No. TRA110-B 17 Sheets 16 Sheet Remark

FUJI YIDA 6

7

8

1

2

3

4

5

6

8

7

JC11 Plug(350536-1)

D

Plug(1-480705-0)

Pin No. Wire No.

1 2 3 4 5

24T GND1 C+ C(E)

D

TVVP4

6

JC10

Plug(172347-1)Pin(170308-1) C

1 2 3 4 5 6 7 8 9 10 11 12 13

1 2 3 4 CH-4

1 2 3 4 J2

Pin No.Wire No.

J9-1 J9-2 J9-3 J9-4 J9-5 J9-6 J9-7 J10-5 J10-6 J11-1 J11-2 J11-3 J11-4

CMM KMV1 GMV1 KAB CZ MZ KAB2 KMV2 GMV2 BLV+ BL1 N ZM

Car indicator

J1

IC Card Reader

Open door KMD1

J1

1 2 3 J2

J6-1 J6-2 J6-3

SKM1

CZB

4

KYD SKY Door open delay

J6-4

Close door GMD1

CH-4 1 2 3 4

1 2 3 J3

J10-7 J10-8

RT+ CMM

4

J10-9

SGM1

RTRS-485 Serial load communication C

24V

J10-10

JC09 Pin Wire No. YJ+ 1 2

YJ+ YJ-

YJ-

EYJ Emergency Light

1 2 3 J4

CZB-01

J9-1

4

For rear door if any 1 2 3 J5

Plug(171830-1) Pin(170308-1)

B

A

6

SZS

Bypass

J9-10

SZH

By attendant

1 2 3

ND1

1st floor car call SN1

4

Call Button

B1 B2 B3 B4

B1 B2 B3 B4

Special

SZY

J10-2

4

Hands-free Intercom (COP)

3 4 5

JN1

CMM

J10-1

+ R

1 2

Red Black

ND8

JN8 3

L

8th floor car call B

SN8

4

J1 J12

CZB-EB J2

9 10 11 12 13 14 15 16 17 18 19 20 21

J1 105 106 L33 FA EM JL+ JL1

SDC Emergency stop in car

105 106 L33 FA EM

SFA SJM1

JL+ JL1

JL

CZB-EB J2

Fan

Alarm

A

Design Check Approve

Note: 1. After the COP wiring is finished ,the plug should be made by the drawing. 2. The drawing is for BEST intercom ,Laogang intercom has different wire connection ,wire No. B1-B6.

COP wiring

Date

Draw No. Sheets Sheet Remark

TRA110 17 17

FUJI YIDA 1

2

3

4

5

6

7

8