ELE 2000 CONTROL BOARD AND LIFTS COMPONENTS

ELE CAN Lift System

ELE 2000 s.r.l. , via Borsini, 14 20094 CORSICO (MI) – ITALY Tel. +39 02 4502779 – FAX +39 02 48601162 E-mail: [email protected] www.ELE-2000.com

ELE CAN LIft

1

ELE CAN Lift System ELE CAN Lift System is a modular HW and SW platform, which allows to realize serial lift control system for traction and hydraulic lifts up to 32 stops automatic pushbutton or simplex collective, as well as multiplex. Thanks to the CANbus network, ELE CAN Lift system is very flexible and suitable for most of the requested configurations, through the choice of the proper system architecture and configuration. A typical system in the picture: .

The system can be adapted to the different plant configurations changing the programming parameters value on ECL1 board. ELE CAN LIft

2

Lay-out ECL1 board

ELE CAN LIft

3

Variables and parameters are identified by a unique code and description. The first left code figure, identify the group. The following 2 figures are the variable/parameter number.

Example : 1 01 I IRU -- --- -------| | |__________ Description. | |______________ Variable/parameter number. |________________Group: On-Line =0 Monitor =1 Parameters =2

Keyboard.

• • • •

ELE CAN LIft

ESC:

Exit from the active menu. Exit from the editing mode without confirm the new data. UP: Move the cursor up. (navigation) Increase the numeric value. (editing) DOWN: Move the cursor down. (navigation) Decrease the showed numeric value. (editing) ENTER: Editing mode activation. Move the cursor on the next digit on the multi figures variables. Confirm the data.

4

Rotary-Switch SW2 ECL1 board address selection. In Automatic Push Button control or Simplex Collective the ECL1 address must be set =1.

Dip-Switch SW1 Through Dip-Switch SW1 the system functioning mode is selected With OFF state it mean the switch pulled up. With ON state it mean the switch pressed down to the printed circuit. 2 OFF OFF ON ON

1 OFF ON OFF ON

Functioning mode Active system Normal functioning Inspection/Maintenance Access allowed only when lift Installation is stopped. User menù

Display LCD. 1. SYSTEM STATUS • ALARMS: Show the last alarm code and description. To delete alarms: Keep pressed the “ESC” and “ENTER” keys at the same time until on LCD display appears the confirmation message. • INSTALLATION: Completely Manual mode. The CAN-BUS communication isn’t controlled. The system check only the safety circuit, PTC and contactors control.



a. EXC. b. SC1. c. SC2. d. SC3. e. PTC f. I 1- I 2- I 3 INSPECTION/MAINTENANCE: Assisted manual mode.



RUN MODE: Automatic mode.

Note: In all the functioning mode it’s possible to access alternatively to : • Alarms history. Show the last 40 alarms. • On-Line parameters group. Show in automatic mode the active system functions. 2. USER MENÙ • MONITOR: Show the system variable. •

PARAMETERS: Show and edit system configuration parameters.



UTILITY: Show Alarms History and Memory Functions.



Alarms History

Æ Show lasts 40 alarms. Is possible to clear the list.

Memory Function

Æ Allows the memory sim identification.

LOGIN: Allows the submenù SERVICE visualisation on user menù. - Password - Logout

ELE CAN LIft

Æ Visualisation submenù code. Æ Allows to hide submenù service. 5

QUICK KEYBOARD FUNCTIONS Single landing calls: it is possible to place single landing calls by pressing for 3 seconds the pushbutton ENTER on keyboard Once the function has been accepted, you can increase or decrease the desired landing floor by pressing the ENTER or ESC pushbuttons. Once the landing floor has been selected, by pressing together the ENTER and ESC pushbuttons you will place the call to the desired floor. Alarm visualization: it is possible to visualize the alarms without entering MENU by simply pressing the pushbutton ESC for 3 seconds. Once the alarms have been visualized, it is possible to scroll through them by pressing the pushbutton ENTER to go up and ESC to go down. For see the alarms data, press and hold ESC for 6 seconds. If you want to cancel all memorized alarms, please press together the pushbuttons ENTER and ESC. NOTE: 103 CODE INFORM YOU THE LIFT HAS BEEN SWITCHED OFF AND ON.

Alarms Code 0-31 41 42 43

46 47 48 49 50 51 52 53 57 58

Name IRD-IRU Refasing ID ReedSwitch IU ReedSwitch

Description Safety chain opened at nth floor. IRD and IRU always opened or interrupted wires ID (IF) reed switch doesn’t change IU (ICV) reed switch doesn’t change

SS Low Command UD Low Command HS Low Command U High Command D High Command HS High Command SS High Command Safety Chain1 SC3 Safety Chain SC2 Safety Chain SC3

KPV or KL contactor stuck KS or KD contactor stuck KGV contactor stuck KS contactor defective or wires interrupted KD contactor defective or wires interrupted KGV contactor defective or wires interrupted KPV contactor defective or wires interrupted Safety chain opened during lift re-phasing SC2 open during travel SC3 open during travel

ELE CAN LIft

Type

6

Notes

Floors doors contacts Car doors contacts Floors doors contacts

Code 59 64

Name CarCommunication MotorTempTooHigh

Type **

Description C00 Car communication alarm Motor temperature too high or controller termostat

80

TOut Max Travel

*

Exceeding maximum travel time

81 82 83 84

FinalLimitSwitch TMax Relevelling Safety Module Wrong Direction

* * * *

Over-travel Exceeding maximum re-levelling time Defective safety circuit device(re-levelling) Opposite direction to the set one.

100 101

MemoryWriteError MemoryReadError

103

System Init.

Notes Door opening Pushbutton active Door opening Pushbutton active if lift not start from the stop Door opening Pushbutton active Door opening Pushbutton active Door opening Pushbutton active Door opening Pushbutton active

Note: The alarms are automatically reset once the fault is removed. I.E. safety chain closed. * For this alarms is required the acknowledgement from operator man by pressing at the same time “ESC” and “ENTER” key. The acknowledgement request remains active also in case of shut down or board reset. ** For this alarms the acknowledgement can be automatic or manual from operator man and depend by program.

ELE CAN LIft

7

Monitor Code 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129

Name 101I IRU 102I IRD 103I IU 104I ID 105I EXC 106I SC1 107I SC2 108I SC3 109I ISP 110I IUB 111I IDB 112O ISP 113I OVC 114O OSE 115I FLC 116I MP 117I PAC A+ 118I CFTC1 119I CFTC2 120I CFTC3 121I CCM1 122I CCM2 123I CCM3 124I DOB 125I DCB 126O KA 127O KAB 128O KAC 129O KC

ELE CAN LIft

Range 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1 0-1

Description Input Up Re-phasing switch Input Down Re-phasing switch Input reed switch UP Input reed switch DOWN Input over-travel Input SC1 Input SC2 Input SC3 Input Inspection operating Input inspection UP button Input inspection DOWN button Output inspection Input Over load contact Output Over load Input Full Load contact Input Movable platform contact MP Italian Ministerial Decree 236 Alarm input Input photocell 1 Input photocell 2 Input photocell 3 Input Retiring cam 1 Input Retiring cam 2 Input Retiring cam 3 Input door opening push button Input door closing push button Output door opening 1 Output door opening 2 Output door opening 3 Output doors closing 8

Notes

Code 130 131

Name 130O KRP 131I PTC

Range 0-1 0-1

132

132Call Type

0-2

133

133Lift Type

0-4

134

134Door type

0-2

135 136 137 138 197 198 199

135Floors N. 136Stops N. 137ECL2 Shaft 138Func. Type 197Plant 198ConfVers 199SW Vers

2 - 32 2 - 40 xx x xxxxx xxxx xxxx

ELE CAN LIft

Description Output Retiring Cam Motor temperature alarm. 0 =Automatic Pushbutton control. 1 =Simplex collective/ Simplex down. 2 =Full collective/ 0 = Hydraulic Lift, direct starting. 1 = Hydraulic Lift, Star/Delta starting. 2 = Traction one speed. 3 = Traction two speeds. 4 = Traction VVVF drive. 0 =Manual. 1 =Semiautomatic. 2 =Automatic. Configured floors number Configured stops number Number of ECL2 on the shaft configured Plant reference number Configuration version Software version

Notes

Calls type

Lift Type

Doors Type

Depending by tecnical data

9

Parameters Address 201

Name 201T Max Open

Range 0-50 sec

202

202T Open Del

0-50 sec/10

203

203T MaxClose

204

T value 8 sec

Description Doors opening maximum time.

4

0,4 sec

Delay in doors opening at floor arrival.

0-50 sec

8

8 sec

204T CloseDel

0-50 sec

3

3 sec

205

205T No Start

10-99 sec

15

15 sec

35

35 sec

206

206T MaxTrav

10-98 sec

40

40 sec

207

207T ForClose

0-99 sec x2

10

20 sec

Doors close maximum time. Waiting time from end of opening before close door. Maximum delay in leaving from start of doors closing. Maximum travel time traction lifts Maximum travel time hydraulic lift. If V =0,15m/s is set to 45 sec. Forced close doors time. See too PAR. 314

208

208T ShFlrdel

0-99 sec/10

5

0,5 sec

Delay in slowing down time for closet floors

209

209T In Use

0-99 sec

4

4 sec

In use time

210

210T SD Start

0-99 sec/10

10

1 sec

Start/delta commutation time

3

0,3 sec

Setting time on traction lift 2 speed

2

0,2 sec

211

221T Stop Del

0-99 sec/10

212

Default 8

15

1,5 sec

9

0,9 sec

Maximum time between two floors. The counter is resets at each floor. if = 99 doesn’t work Nudging The lift go in slow speed on the floor magnet before the floor called and after setting time. Time inhibition floors pushbuttons after doors opening Don’t change Traction lift with VVVF drive Hydraulic lift with Bucher

212T ParkStop

0-99 sec x10

18

3 min

Waiting time for parking return. Active if Par. 229 enabled

216T KCDisDel

0-99 sec/2

1

0,5 sec

Doors close disable command delay

214 215

ELE CAN LIft

At doors closing end it resets

Hydraulic lift and traction lift 1spd/2spd Delay in contactors drop at stop

213

216

Notes At doors opening end it resets

10

The function is disabled on hydraulic lifts

Address

Name

Range

217

217T ReopeDel

0-99 sec/4

218

218T RecloDel

219 220 221 222

T value

Description

1

0,25 sec

Delay doors on changing direction

0-99 sec/4

4

1 sec

Close doors delay after a doors reopening.

219T CarLight

0-99 sec x10

12

120 sec

Car light turn off time.

222DoorMotorON

0–1

0

223

223RetiringCam

0–1

0

Retiring Cam enable.

0 = Off , 1 = On

224

224MP

NC-NO

0–1

1

Contact type MP 0 =NC , 1= NO.

Movable platform

225

225FLC NC-NO

0–1

1

Contact type FLC 0 =NC , 1= NO

Full load

226

226OVC NC-NO

0–1

1

Contact type OVC 0 =NC , 1= NO

Over Load

227

227Floors N.

2 – 32

xx

Floors number

Set floor number

228

228Stops N.

2 – 40

xx

Stops number

229

229ParkStop

2 – 99

99

Parking stop, function disabled in hydraulic lift

Set Stops number. Function disabled if parking floor is over to max stops number. Connected to Par. 212

230

230EmergStop

0 – 39

0

Emergency floor

231

231ClosAttempt

1–5

3

Close doors attempt number

If SC3 Input isn’t closed

232

232StopSelect

00 – 39

x

Stop configuration selection.

If you have more stops at the same floor.

233

233StopFloor

00 – 31

x

Floor number at the selected stop

234

234StpConfig

00 – 16

1

235

235StopDYCode

00 – 255

x

236

236CPK NC-NO

0 -1

1

Define the Number/Type of doors at the selected stop. Code for the DY message to display at the selected stop Contact type CPK 0= NC; 1= NO

237

237FKFC NC-NO

0-1

1

Contact type FKFC 0= NC; 1= NO

Fireman key input

238

238FireStop1

0 – 39

0

Selection of the first fireman stop

Connect to the first fireman input

239

238FireStop2

0 – 39

99

Selection of the second fireman stop

Connect to the second fireman input

ELE CAN LIft

Default

Notes On intervention of photocell during close door command from board Timed light

Door motor supplied during the travel

11

Select too short floor/….

Priority key input

Address

Name

240

240FireDoorC/O

241

Range

Default

0 -1

1

241D.StartSV

0-99 sec/10

0

242

242PreOpening

0 -1

0

243

243RemoteCalls

0–3

0

244

244RefasType

0–1

1

245

245RefAfterIsp

0–1

0

246

246Isp Stop

0-3

3

247

247Gong SS/FL

0-1

248

248 2 GongDown

0–1

0

249

249Gong KA

0–1

1

250

250Arrows Type

0–1

0

251

251Max Reserv.

1–9

1

252 253 254 255 256 298

252Hour 253Minutes 254Day 255Month 256Year 298Language

0 – 23 0 – 59 1 – 32 1 – 12 xx 0–1

xx xx xx xx xx 1

ELE CAN LIft

0

T value

0 sec

Description 0 = Closed 1 = Open Start delay output for voice announcer

Notes Parking doors Type in fireman function Not visible on user menù

Set pre-opening door 0 =Off ,1 =On On vvvf lift require safty chain device 0 = disable Type of Automatic calls 1 = Aut. & man Accept from car with doors opening Usable to test the elevator 2 = Aut. & man Accept from car without doors opening after installation automatically 3 = Man Accept from car and ECL1 keypad and not automalically 0 = manual Re-phasing after pushbuttons calls 1 = Produce automatic Re-phasing on power on 0 = no Re-phasing after inspection Hydraulic and traction elevators 1 = yes Re-phasing after inspection 0=ISP at low speed and stop on IRU/IRD 1 =ISP at low speed and stop on IU/ID For case 3 the lift go in slow speed on IRD 2 =ISP at high speed and stop on IRU/IRD or IRU bi-stable 3= ISP at high speed and stop on IU/ID 0 =gong on change of speed Set the function of the gong 1 =gong at the stop 0 =1 Set a double out for the gong If you use 1 pulse on up, 2 pulses on down 1 =1 Set a single out for the gong If you use 1 pulse on up, 1 pulse on down If enable, the gong output work also when 0 =disable the car is at floor level and the landing call at 1 =enable this floor is press 0 =direction arrows Set type of arrows 1 =next direction arrows Numbers of call accepted for every lift on Is active only for Multiplex plants Multiplex logic Set hour Set minutes Set day Set month Set year (two last digit) 0 = Italian , 1 = English Set the language for board’s display 12

Utility Address Name

Range

Default

501

501Alarms Hyst.

0-1

0

503

503ECL1 Test

0–1

0

504

504MemFunc.

0 - 9999

ELE CAN LIft

Description 0 =disable 1 =enable 0 =disable 1 =enable Memory function, Identification Error

13

Notes Open Alarms History from menu ECL1 ELE2000 Standard Test Require factory support