Ultralink & Ultrawire ULTRALINK • Communication between surface & downhole

ULTRAWIRE • Communication downhole in tool string

X T U

Ultrawire bus

Tool 1

Tool 2

Tool 3

Tool 4

1 Ultralink & Ultrawire 6/18/2019

GE/Sondex system Laptop USB

DRS013 Panel

or Dummy line

Terminator

XTU Ultrawire tools 2 Kuwait 18 March 2012

GE/Sondex system DIU003

Laptop

Depth

USB Wireline

ULP002 Panel

or Dummy line

Terminator

XTU Ultrawire tools 3 Kuwait 18 March 2012

Downhole Controllers • XTU for Surface readout Crossover Telemetry unit

• UMT for Memory operations (Slickline or Coiled tubing etc) Ultrawire Memory Tool

4 Ultralink & Ultrawire 6/18/2019

Ultrawire Terminator • Filters HF noise on telemetry • Prevents overshoots • Terminator built into all “end” Spinners • BUL006 Bullplug with terminator

Terminator Bullplug – BUL006

XTU or UMT must go on top!

DRS013 Portable Surface Readout Acquisition System

8 Ultralink & Ultrawire 6/18/2019

ULP002 Ultralink panel

9 Ultralink & Ultrawire 6/18/2019

10 Ultralink & Ultrawire 6/18/2019

DIU panel – Depth Interface Unit

11 Ultralink & Ultrawire 6/18/2019

12 Ultralink & Ultrawire 6/18/2019

DRS013 Panel

Surface system

Dummy Line – or Wireline

Offshore Operations

16 Ultralink & Ultrawire 6/18/2019

Production Logging

Memory

Surface Read Out

Depth Time Recorder

Memory Interface Panel

HADES

Memory Production Logging Tool & Battery

Ultrawire Memory Tool & Battery

1 3/8” (35mm)

Gamma Ray

Telemetry Tool

Portable Logging System

U L T R A W I R E

B U S

1 11/16” (43mm) Pressure

SCT

Pressure & CCL

Rack Mounted Logging Systems

Cable Head

Knuckle Joint

SCT

Pressure & CCL

1 11/16” (43mm) Add-in Sensors

Radioactive Density or FDI

Casing Collar Locator

Differential Pressure Density

Gas Hold-up Tool

MAPview Compensated Neutron

Temperature

Cable Head Knuckle Joint

Gamma Ray 3 Arm Centraliser Bullnose

Capacitance Temperature Flow

Capacitance Temperature Flow

1 11/16” (43mm) Accessories

Gravel Pack Gamma Ray

Radioactive Density

Multiple Array Production Suite, MAPS

3 Arm Centraliser

Capacitance Water Hold-up

Flowmeter Electronics

4 Arm Centraliser

Head Tension Unit

Swivel Joint Dual In-Line Calliper Spinner

Diverter Basket Flowmeter

Inclinometer Accelerometer Bullnose

Cagerd Fullbore Spinner

Jewelled Bearing Flowmeter

Continuous Flowmeter

3 Arm Easy Entry Centraliser OD Adapter

Springbow Centraliser

Tungsten Weight Bar

Downhole Controller XTU ULTRALINK 80674 XTU PSU Telemetry PCB

120-300VDC

ULTRALINK MODEM

ULTRAWIRE PSU (SMPS) +5 V

• Modem to surface, ULTRALINK • Uplink at 50, 75 or 100kb/s (option of 200kb/s) • Downlink at 300b/s every 15secs – If no response, reduces telemetry rate Modem to sensors, ULTRAWIRE • XTU on power up ‘sees’ what tools below >170V cablehead voltage

15-18VDC CONTROLLER

• Creates “Service Table” Lowest tool address first, maximum of 62 tools

ULTRAWIRE MODEM

80672 XTU Processor PCB ULTRAWIRE

(subject to power requirements)

Power supply • Converts high voltage DC, 200V, from the Ultralink to low voltage DC, 18V (17.8V), for the Ultrawire. Current consumption at 200V 20mA (no Load), 28-30mA (running SCT) • XTU002 has HVOLTS & ITEMP curves, max 200°C (392°F) sensor by PSU transformer

Sondex tool addresses

Ultrawire The Ultrawire™ protocol includes commands for: • data acquisition • tool configuration • tool software and parameter download • control of motorised tools • bandwidth sharing with other nonUltrawire™ modulation schemes over the same monocable bus.

20 Ultralink & Ultrawire 6/18/2019

Ultrawire Memory The Ultrawire™ memory system

• Data is transmitted via the Ultrawire™ toolbus to the memory tool at the top of the toolstring. • Data is stored in non-volatile flash memory chips under the control of a downhole processor. • 128MB of memory. (UMT007 = 1GB) • The tool supports all the standard Ultrawire™ tools.

21 Ultralink & Ultrawire 6/18/2019

Programming & Logging Memory Tool (UMT) Slickline Winch or Coiled Tubing Unit

UM T

Depth Encoder

22 Ultralink & Ultrawire 6/18/2019

ULTRALINK & ULTRAWIRE Amplitude approx. 4 – 5 Vp/p. Data pulse should return to baseline, max 20% overshoot permissible. Adjust panel Equaliser for best compromise between pulse overshoot and low frequency ‘wobble’ on the signal baseline. Sour cables (H2S) • overshoot can be excessive, can not equalise • modify panel with kit number KITU-32-ULP DRS (daughter card to the back of the main equaliser board, and software)

Equalization

Correct

Equalization adjusts the amount of high frequency boost applied to the uplink signal. Oscilloscope is strongly recommended

Under equalised

Over equalised

Equalization

Correct

Equalization adjusts the amount of high frequency boost applied to the uplink signal. Oscilloscope is strongly recommended

Under equalised

Over equalised

Ultrawire toolbus signal

CE mod to DRS013 87512 CE Current Trip boards. You will need to exceed 60v / 10mA in 5 secs or the Current Trip will operate.