39 1 2MB
Ultralink & Ultrawire ULTRALINK • Communication between surface & downhole
ULTRAWIRE • Communication downhole in tool string
X T U
Ultrawire bus
Tool 1
Tool 2
Tool 3
Tool 4
1 Ultralink & Ultrawire 6/18/2019
GE/Sondex system Laptop USB
DRS013 Panel
or Dummy line
Terminator
XTU Ultrawire tools 2 Kuwait 18 March 2012
GE/Sondex system DIU003
Laptop
Depth
USB Wireline
ULP002 Panel
or Dummy line
Terminator
XTU Ultrawire tools 3 Kuwait 18 March 2012
Downhole Controllers • XTU for Surface readout Crossover Telemetry unit
• UMT for Memory operations (Slickline or Coiled tubing etc) Ultrawire Memory Tool
4 Ultralink & Ultrawire 6/18/2019
Ultrawire Terminator • Filters HF noise on telemetry • Prevents overshoots • Terminator built into all “end” Spinners • BUL006 Bullplug with terminator
Terminator Bullplug – BUL006
XTU or UMT must go on top!
DRS013 Portable Surface Readout Acquisition System
8 Ultralink & Ultrawire 6/18/2019
ULP002 Ultralink panel
9 Ultralink & Ultrawire 6/18/2019
10 Ultralink & Ultrawire 6/18/2019
DIU panel – Depth Interface Unit
11 Ultralink & Ultrawire 6/18/2019
12 Ultralink & Ultrawire 6/18/2019
DRS013 Panel
Surface system
Dummy Line – or Wireline
Offshore Operations
16 Ultralink & Ultrawire 6/18/2019
Production Logging
Memory
Surface Read Out
Depth Time Recorder
Memory Interface Panel
HADES
Memory Production Logging Tool & Battery
Ultrawire Memory Tool & Battery
1 3/8” (35mm)
Gamma Ray
Telemetry Tool
Portable Logging System
U L T R A W I R E
B U S
1 11/16” (43mm) Pressure
SCT
Pressure & CCL
Rack Mounted Logging Systems
Cable Head
Knuckle Joint
SCT
Pressure & CCL
1 11/16” (43mm) Add-in Sensors
Radioactive Density or FDI
Casing Collar Locator
Differential Pressure Density
Gas Hold-up Tool
MAPview Compensated Neutron
Temperature
Cable Head Knuckle Joint
Gamma Ray 3 Arm Centraliser Bullnose
Capacitance Temperature Flow
Capacitance Temperature Flow
1 11/16” (43mm) Accessories
Gravel Pack Gamma Ray
Radioactive Density
Multiple Array Production Suite, MAPS
3 Arm Centraliser
Capacitance Water Hold-up
Flowmeter Electronics
4 Arm Centraliser
Head Tension Unit
Swivel Joint Dual In-Line Calliper Spinner
Diverter Basket Flowmeter
Inclinometer Accelerometer Bullnose
Cagerd Fullbore Spinner
Jewelled Bearing Flowmeter
Continuous Flowmeter
3 Arm Easy Entry Centraliser OD Adapter
Springbow Centraliser
Tungsten Weight Bar
Downhole Controller XTU ULTRALINK 80674 XTU PSU Telemetry PCB
120-300VDC
ULTRALINK MODEM
ULTRAWIRE PSU (SMPS) +5 V
• Modem to surface, ULTRALINK • Uplink at 50, 75 or 100kb/s (option of 200kb/s) • Downlink at 300b/s every 15secs – If no response, reduces telemetry rate Modem to sensors, ULTRAWIRE • XTU on power up ‘sees’ what tools below >170V cablehead voltage
15-18VDC CONTROLLER
• Creates “Service Table” Lowest tool address first, maximum of 62 tools
ULTRAWIRE MODEM
80672 XTU Processor PCB ULTRAWIRE
(subject to power requirements)
Power supply • Converts high voltage DC, 200V, from the Ultralink to low voltage DC, 18V (17.8V), for the Ultrawire. Current consumption at 200V 20mA (no Load), 28-30mA (running SCT) • XTU002 has HVOLTS & ITEMP curves, max 200°C (392°F) sensor by PSU transformer
Sondex tool addresses
Ultrawire The Ultrawire™ protocol includes commands for: • data acquisition • tool configuration • tool software and parameter download • control of motorised tools • bandwidth sharing with other nonUltrawire™ modulation schemes over the same monocable bus.
20 Ultralink & Ultrawire 6/18/2019
Ultrawire Memory The Ultrawire™ memory system
• Data is transmitted via the Ultrawire™ toolbus to the memory tool at the top of the toolstring. • Data is stored in non-volatile flash memory chips under the control of a downhole processor. • 128MB of memory. (UMT007 = 1GB) • The tool supports all the standard Ultrawire™ tools.
21 Ultralink & Ultrawire 6/18/2019
Programming & Logging Memory Tool (UMT) Slickline Winch or Coiled Tubing Unit
UM T
Depth Encoder
22 Ultralink & Ultrawire 6/18/2019
ULTRALINK & ULTRAWIRE Amplitude approx. 4 – 5 Vp/p. Data pulse should return to baseline, max 20% overshoot permissible. Adjust panel Equaliser for best compromise between pulse overshoot and low frequency ‘wobble’ on the signal baseline. Sour cables (H2S) • overshoot can be excessive, can not equalise • modify panel with kit number KITU-32-ULP DRS (daughter card to the back of the main equaliser board, and software)
Equalization
Correct
Equalization adjusts the amount of high frequency boost applied to the uplink signal. Oscilloscope is strongly recommended
Under equalised
Over equalised
Equalization
Correct
Equalization adjusts the amount of high frequency boost applied to the uplink signal. Oscilloscope is strongly recommended
Under equalised
Over equalised
Ultrawire toolbus signal
CE mod to DRS013 87512 CE Current Trip boards. You will need to exceed 60v / 10mA in 5 secs or the Current Trip will operate.