General Physics 2/Physics 3 Laboratory

LAB REPORT 7

MAGNETIC FIELDS OF COILS

Date of Experiment: ........................................... Date of Report:04/06/2021 Members: 1. ................................ Phạm Hồng Đăng ................................ – ITITIU19009 ........ 2. ................................ Lê Nhựt Minh –................................ CECEIU19019 ........ 3. ................................ Chung Hoàng Nam ................................ – CECEIU19020........ 4. ................................ Lê Minh Huy – CECEIU19010 ........................................ 5. ................................ Nguyễn Thành Hưng ................................ – CECEIU19009 ........

1

2019

General Physics 2/Physics 3 Laboratory

2019

1. What is the purpose of the experiment?

Demonstrating the magnetic field in various point don't have a similar worth. The distance of those points in the trial are influenced by the magnetic of inductor. We simply make almost no impact to the worth of the examination, analyze the field from the Helmholtz coins at the appropriate partition of the coin radius to the field from coins isolated at not exactly or more than the coin radius. Eyewitness the magnetic field inside the solenoid fulfill with the recipe or not. 2. Briefly describe the experiment in your own words?

First, we turn on the voltage machine and set it to 1V. we move the magnetic sensor go through the inductor to make the magnetic field and recorded the chart of the magnetic field on Data Studio program. Making the diagram to center and afterward set the formula by z = x – d, after that we fill in worth of capacitance, inductance, resistance, distance of the inductor. We utilize the savvy zoom to discover the most extreme voltage worth of the chart and record to the report. In the second experiment, we simply need to add 1 more inductor series with the past one in the first experiment and the distance of the subsequent inductor has appeared in the lab guide. For the third test, we simply change the radius which is smaller than the radius from 2 past test and see what occur inside and outside the coin form that contrasting with the theory. For the solenoid explore we simply supplant the inductor by the solenoid and methodology the test precisely first test. 3. Magnetic fields of a single coil (attach the graph describing the magnetic field strength along the axis perpendicular to the coil plane and through the center of the coil in the report): Base on your graph, does the theoretical line fit the experimental data everywhere? Explain.

2

General Physics 2/Physics 3 Laboratory

2019

Structure the diagram we can see that the theory magnetic field line isn't equivalent to the experiment information we recording by Data Studio, yet additionally understand the bend of the experiment is almost fit with the hypothetical chart, so it is very satisfactory. The justification the diverse between the experiment advertisement hypothetical magnetic field line is: First when measure the magnetic field sensor doesn't go 100% corresponding with the coil axis. Second explanation is the influencing structure the climate magnetic field around the coillike computer, cellphone. Third reason is the instrument we use: magnetic field sensor, the DataStudio software, the ScienceWorkshop not perform perfectively 4. Magnetic fields of two coils (attach the graph describing the magnetic field strength along the axis perpendicular to the coil planes and through the center of the coils in a case d 10.5cm in the report): Base on your graph, do the theoretical lines fit the experimental data everywhere? Explain. 3

General Physics 2/Physics 3 Laboratory

2019

Case d = 10.5 cm

Base on the graph we can see that the theoritical magnetic field line doesn't fit to the experiment recorded by the DataStudio software however in the overall the bend of the two diagrams is the very fit together. The reason for this distinction of them is while method the experiment the distance of 2 coils is not equal to half of the radius or the worth of radius we supplement to the recipe to make the theoritical lines aren't right. 5. Magnetic fields of a solenoid (attach the graph describing the magnetic field strength as a function of location in the report): Calculate the magnetic field strength inside the solenoid. Compare with the value found from your experimental data.

4

General Physics 2/Physics 3 Laboratory

𝐵 = 𝜇𝑛𝐼 =

5

𝜇𝑁𝐼 0.0126 ∗ 200 ∗ 0.1 = = 36.07 𝑇 𝐿 0.102

2019