34 1 743KB
Antenna Integrated Radio Unit Description AIR 6419 Description
Ge23266B
302/1551-LZA 701 6001/1 Uen Y
Copyright © Ericsson AB 2021, 2022. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner. Disclaimer The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document. Trademark List All trademarks mentioned herein are the property of their respective owners. These are shown in the document Trademark Information.
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Contents
Contents 1
Product Overview
1
1.1
Variants
1
2
Technical Data
2
2.1
Radio Capabilities
2
2.2
Output Power
2
2.3
EIRP Data
2
2.4
Physical Characteristics
8
2.5
Operating Environment
10
2.6
Wind Load
10
2.7
Heat Dissipation
10
2.8
Vibration
11
2.9
Acoustic Noise
11
2.10
Power Supply Characteristics
11
2.11
RF Electromagnetic Field Exposure
12
2.12
Software
16
2.13
Radio Configurations
16
3
Hardware Architecture
17
4
Installation Requirements
19
4.1
Outdoor Installation Environments to Avoid
19
4.2
Installation Alternatives
20
4.3
Space Requirements
21
4.4
Painting Disclaimer
22
5
Interfaces
23
5.1
Optical Cable Interfaces
25
5.2
DIN 14-Pin Interface
25
5.3
TX Monitor Interface (Optional)
26
5.4
−48 V DC Power Supply Interface
26
5.5
Grounding Interface
26
5.6
Optical Indicators
27
6
Standards and Regulations
28
6.1
Regulatory Approval
28
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Antenna Integrated Radio Unit Description
6.2
Other Standards and Regulations
31
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Product Overview
1
Product Overview AIR 6419 has the following main features: — Designed for outdoor use, for wall, pole, tower, or mast mounting — Mid band — NR and LTE TDD support, see Supported Radio Capabilities — Up to 64TX/64RX branches, see Supported Radio Capabilities — Mixed mode support, see Supported Radio Capabilities — Support for Massive MIMO, see Supported Radio Capabilities — Vertical and horizontal beamforming — Tilt and swivel support — EC light — The power connection supports 2-wire (DC-C)/3-wire (DC-I) — 2 eCPRI up to 25.8 Gbps per port — Basic Stand-alone Radio Installation Check support — Complies with 3GPP base station class Wide Area. For a list of relevant standards, see Radio Standards Compliance on page 30. The product is equipped with one or more warranty seal stickers. Note:
1.1
Seals that have been implemented by Ericsson must not be broken or removed, as it otherwise voids warranty.
Variants — AIR 6419 B40 — AIR 6419 B41 — AIR 6419 B42 — AIR 6419 B77G — AIR 6419 B78Y
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
1
Antenna Integrated Radio Unit Description
2
Technical Data
2.1
Radio Capabilities For supported number of carriers, carrier bandwidth, operating bandwidth, IBW, frequency range, detailed RAT support, and mixed mode configurations, see Supported Radio Capabilities. Special considerations might apply for certain configurations, see Building Blocks.
Output Power
2.2
For maximum nominal output power, see Supported Radio Capabilities. Minimum configured output power without degradation in product performance is 20 W. Hardware Activation Codes (HWAC) are required for total output power over 20 W. For detailed information about output power hardware activation codes, see Hardware-Related Capabilities in the Radio Node libraries. For information about maximum output power per carrier type, see Radio Node Configurations.
EIRP Data
2.3
Traffic Beams Table 1
AIR 6419 Typical EIRP Performance Data for Traffic Beams
Product AIR 6419 B40
AIR 6419 B41
AIR 6419 B42
2
Uniform Traffic Beams(1)
Direction
Parameter
H0V6°
H55V6°
H0V19°
Vertical Beamwidth (°)
8
8
8.5
Horizontal Beamwidth (°)
14
22
14.5
Main Beam Peak EIRP (dBm)(2)(3)
2 × 76
2 × 73
2 × 74
Vertical Beamwidth (°)
7.5
7.5
7.5
Horizontal Beamwidth (°)
12.5
20
13
Main Beam Peak EIRP (dBm)(2)(3)
2 × 76.5
2 × 73.5
2 × 74.5
Vertical Beamwidth (°)
7
7
7
Horizontal Beamwidth (°)
12.5
20
13
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Technical Data
Uniform Traffic Beams(1)
Product
AIR 6419 B77G
AIR 6419 B78Y
Direction
Parameter
H0V6°
H55V6°
H0V19°
Main Beam Peak EIRP (dBm)(2)(3)
2 × 77
2 × 74
2 × 74
Vertical Beamwidth (°)
6.5
6.5
7
Horizontal Beamwidth (°)
12.5
20
13
Main Beam Peak EIRP (dBm)(2)(3)
2 × 76.5
2 × 73.5
2 × 74
Vertical Beamwidth (°)
6.5
6.5
6.5
Horizontal Beamwidth (°)
12
19.5
12.5
Main Beam Peak EIRP (dBm)(2)(3)
2 × 76.5
2 × 73
2 × 73.5
(1) The traffic beamforming of this product is not limited to the uniform beamshapes and directions given in the table. The beams are dynamically optimized. (2) The main beam peak EIRP in the table is calculated for two simultaneous orthogonal beams. (3) This value can be limited by the activation of certain features.
Broadcast Beams Table 2
AIR 6419 Typical Antenna Performance Data for Broadcast Beams in Macro Scenario
Product
AIR 6419 B40
AIR 6419 B41
AIR 6419 B42
Scenario: Macro
Beam LTE
Beam NR
Parameter
BrM1(1), BrM2(2)
BrM1(1)
Vertical Beamwidth (°)
8±1
8±1
Horizontal Beamwidth (°)
65±5
65±5
Digital Downtilt (°)
−3 to 11
−3 to 11
Vertical Beam Pointing Error (°)
≤1
≤1
Horizontal Beam Pointing (°)
0±5
0±5
Vertical Side Lobe Suppression (dB)
15
15
Front to Back Ratio (dB)
25
25
Beam Parallelity (BrM1●BrM2) (dB)
≤ –10
n/a
EIRP (Typical) (dBm)
2 × 69
1 × 72
Vertical Beamwidth (°)
7.5±1
7.5±1
Horizontal Beamwidth (°)
65±5
65±5
Digital Downtilt (°)
−3 to 11
−3 to 11
Vertical Beam Pointing Error (°)
≤1
≤1
Horizontal Beam Pointing (°)
0±5
0±5
Vertical Side Lobe Suppression Peak to 20° (dB)
15
15
Front to Back Ratio (dB)
25
25
Beam Parallelity (BrM1●BrM2) (dB)
≤ –10
n/a
EIRP (Typical) (dBm)
2 × 68.5
1 × 72
Vertical Beamwidth (°)
7±1
7±1
Horizontal Beamwidth (°)
65±5
65±5
Digital Downtilt (°)
−3 to 11
−3 to 11
Vertical Beam Pointing Error (°)
≤1
≤1
Horizontal Beam Pointing (°)
0±5
0±5
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
3
Antenna Integrated Radio Unit Description
Product
AIR 6419 B77G
AIR 6419 B78Y
Scenario: Macro
Beam LTE
Beam NR
Parameter
BrM1(1), BrM2(2)
BrM1(1)
Vertical Side Lobe Suppression (dB)
16
16
Front to Back Ratio (dB)
25
25
Beam Parallelity (BrM1●BrM2) (dB)
≤ –10
n/a
EIRP (Typical) (dBm)
2 × 69.5
1 × 72.5
Vertical Beamwidth (°)
n/a
7±1
Horizontal Beamwidth (°)
n/a
65±5
Digital Downtilt (°)
n/a
−3 to 11
Vertical Beam Pointing Error (°)
n/a
≤1
Horizontal Beam Pointing (°)
n/a
0±5
Vertical Side Lobe Suppression (dB)
n/a
16
Front to Back Ratio (dB)
n/a
25
Beam Parallelity (BrM1●BrM2) (dB)
n/a
-
EIRP (Typical) (dBm)
n/a
1 × 72
Vertical Beamwidth (°)
6.5±1
6.5±1
Horizontal Beamwidth (°)
65±5
65±5
Digital Downtilt (°)
−3 to 11
−3 to 11
Vertical Beam Pointing Error (°)
≤1
≤1
Horizontal Beam Pointing (°)
0±5
0±5
Vertical Side Lobe Suppression (dB)
>12
>12
Front to Back Ratio (dB)
25
25
Beam Parallelity (BrM1●BrM2) (dB)
≤ –10
-
EIRP (Typical) (dBm)
2 × 69
1 × 72
(1) Broadcast Beam Macro 1 (2) Broadcast Beam Macro 2
Table 3 AIR 6419 Typical Antenna Performance Data for Broadcast Beams in Macro HSLS Scenario Product
AIR 6419 B41
Scenario: Macro
Beam LTE
Beam NR
Parameter
BrM1(1), BrM2(2)
BrM1(1)
Vertical Beamwidth (°)
7.5±1
7.5±1
Horizontal Beamwidth (°)
65±5
65±5
Digital Downtilt (°)
−3 to 11
−3 to 11
Vertical Beam Pointing Error (°)
≤1
≤1
Horizontal Beam Pointing (°)
0±5
0±5
Vertical Side Lobe Suppression Peak to 20° (dB)
16
16
First Vertical Side Lobe Suppression (dB)
20
20
Front to Back Ratio (dB)
25
25
Beam Parallelity (BrM1●BrM2) (dB)
≤ –10
n/a
EIRP (Typical) (dBm)
2 × 67.5
1 × 71
(1) Broadcast Beam Macro 1
4
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Technical Data
(2) Broadcast Beam Macro 2
Table 4
AIR 6419 Typical Antenna Performance Data for Broadcast Beams in Hotspot Scenario
Product
AIR 6419 B40
AIR 6419 B41
AIR 6419 B42
AIR 6419 B77G
AIR 6419 B78Y
Scenario: Hotspot
Beam LTE
Beam NR
Parameter
BrHS1(1), BrHS2(2)
BrHS1(1)
Vertical Beamwidth (°)
28.5±3
28.5±3
Horizontal Beamwidth (°)
65±5
65±5
Digital Downtilt (°)
Fixed 6
Fixed 6
Vertical Beam Pointing Error (°)
≤1
≤1
Horizontal Beam Pointing (°)
0±5
0±5
Vertical Side Lobe Suppression (dB)
14
14
Front to Back Ratio (dB)
−
−
Beam Parallelity (BrM1●BrM2) (dB)
≤ –10
n/a
EIRP (Typical) (dBm)
2 × 64
1 × 67
Vertical Beamwidth (°)
30±3
30±3
Horizontal Beamwidth (°)
65±5
65±5
Digital Downtilt (°)
Fixed 6
Fixed 6
Vertical Beam Pointing Error (°)
≤3
≤3
Horizontal Beam Pointing (°)
0±5
0±5
Vertical Side Lobe Suppression (dB)
12
12
Front to Back Ratio (dB)
−
−
Beam Parallelity (BrM1●BrM2) (dB)
≤ –10
n/a
EIRP (Typical) (dBm)
2 × 64
1 × 67
Vertical Beamwidth (°)
27±3
27±3
Horizontal Beamwidth (°)
65±5
65±5
Digital Downtilt (°)
Fixed 6
Fixed 6
Vertical Beam Pointing Error (°)
≤1
≤1
Horizontal Beam Pointing (°)
0±5
0±5
Vertical Side Lobe Suppression (dB)
11
11
Front to Back Ratio (dB)
−
−
Beam Parallelity (BrM1●BrM2) (dB)
≤ –10
n/a
EIRP (Typical) (dBm)
2 × 64.5
1 × 67.5
Vertical Beamwidth (°)
n/a
27±3
Horizontal Beamwidth (°)
n/a
65±5
Digital Downtilt (°)
n/a
Fixed 6
Vertical Beam Pointing Error (°)
n/a
≤2
Horizontal Beam Pointing (°)
n/a
0±5
Vertical Side Lobe Suppression (dB)
n/a
11
Front to Back Ratio (dB)
n/a
25
Beam Parallelity (BrM1●BrM2) (dB)
n/a
-
EIRP (Typical) (dBm)
n/a
1 × 66.5
Vertical Beamwidth (°)
26±2
26±2
Horizontal Beamwidth (°)
65±5
65±5
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
5
Antenna Integrated Radio Unit Description
Product
Scenario: Hotspot
Beam LTE
Beam NR
Parameter
BrHS1(1), BrHS2(2)
BrHS1(1)
Digital Downtilt (°)
Fixed 6
Fixed 6
Vertical Beam Pointing Error (°)
≤1
≤1
Horizontal Beam Pointing (°)
0±5
0±5
Vertical Side Lobe Suppression (dB)
>11
>11
Front to Back Ratio (dB)
25
25
Beam Parallelity (BrM1●BrM2) (dB)
≤ –10
-
EIRP (Typical) (dBm)
2 × 63.5
1 × 66.5
(1) Broadcast Beam Hotspot 1 (2) Broadcast Beam Hotspot 2
Table 5
AIR 6419 Typical Antenna Performance Data for Broadcast Beams in Highrise Scenario
Product
AIR 6419 B40
AIR 6419 B41
AIR 6419 B42
AIR 6419 B77G
6
Scenario: Highrise
Beam LTE
Beam NR
Parameter
BrHR1(1), BrHR2(2)
BrHR1(1)
Vertical Beamwidth (°)
28.5±3
28.5±3
Horizontal Beamwidth (°)
22.5±2
22.5±2
Digital Downtilt (°)
Fixed 6
Fixed 6
Vertical Beam Pointing Error (°)
≤1
≤1
Horizontal Beam Pointing (°)
0±5
0±5
Vertical Side Lobe Suppression (dB)
14
14
Front to Back Ratio (dB)
−
−
Beam Parallelity (BrM1●BrM2) (dB)
≤ –10
n/a
EIRP (Typical) (dBm)
2 × 67.5
1 × 71
Vertical Beamwidth (°)
30±3
30±3
Horizontal Beamwidth (°)
20±2
20±2
Digital Downtilt (°)
Fixed 6
Fixed 6
Vertical Beam Pointing Error (°)
≤1
≤1
Horizontal Beam Pointing (°)
0±1
0±1
Vertical Side Lobe Suppression (dB)
12
12
Front to Back Ratio (dB)
−
−
Beam Parallelity (BrM1●BrM2) (dB)
≤ –10
n/a
EIRP (Typical) (dBm)
2 × 67.5
1 × 72
Vertical Beamwidth (°)
27±3
27±3
Horizontal Beamwidth (°)
20±2
20±2
Digital Downtilt (°)
Fixed 6
Fixed 6
Vertical Beam Pointing Error (°)
≤1
≤1
Horizontal Beam Pointing (°)
0±5
0±5
Vertical Side Lobe Suppression (dB)
11
11
Front to Back Ratio (dB)
−
−
Beam Parallelity (BrM1●BrM2) (dB)
≤ –10
n/a
EIRP (Typical) (dBm)
2 × 68.5
1 × 72
Vertical Beamwidth (°)
n/a
20±2
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Technical Data
Product
AIR 6419 B78Y
Scenario: Highrise
Beam LTE
Beam NR
Parameter
BrHR1(1), BrHR2(2)
BrHR1(1)
Horizontal Beamwidth (°)
n/a
27±3
Digital Downtilt (°)
n/a
Fixed 6
Vertical Beam Pointing Error (°)
n/a
≤2
Horizontal Beam Pointing (°)
n/a
0±1
Vertical Side Lobe Suppression (dB)
n/a
11
Horizontal Side Lobe Suppression (dB)
n/a
17
Front to Back Ratio (dB)
n/a
28
Beam Parallelity (BrM1●BrM2) (dB)
n/a
-
EIRP (Typical) (dBm)
n/a
1 × 71
Vertical Beamwidth (°)
26±3
26±3
Horizontal Beamwidth (°)
20±2
20±2
Digital Downtilt (°)
Fixed 6
Fixed 6
Vertical Beam Pointing Error (°)
≤1
≤1
Horizontal Beam Pointing (°)
0±1
0±1
Vertical Side Lobe Suppression (dB)
>11
>11
Horizontal Side Lobe Suppression (dB)
>14
>17
Front to Back Ratio (dB)
28
28
Beam Parallelity (BrM1●BrM2) (dB)
≤ –10
-
EIRP (Typical) (dBm)
2 × 68
1 × 71.5
(1) Broadcast Beam Highrise 1 (2) Broadcast Beam Highrise 2
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
7
Antenna Integrated Radio Unit Description
2.4
Physical Characteristics W
H
D Ge23267A
Figure 1 AIR 6419 Dimensions
D
H
W Ge25393A
Figure 2 AIR 6419 B41 Dimensions
8
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Technical Data
Table 6
AIR 6419 Dimensions
Product
Height, H (mm)
Width, W (mm)
Depth, D (mm)
AIR 6419 B40 With (R-state < protrusions R1E) Without protrusions
929
506
208
852
506
160
876
506
203
852
506
160
AIR 6419 B42 With protrusions
796
408
186
Without protrusions
717
408
140
With protrusions
793
408
230
Without protrusions
717
408
184
With protrusions
796
408
201
Without protrusions
717
408
155
AIR 6419 B40 With (R-state ≥ protrusions R1E) Without AIR 6419 B41 protrusions
AIR 6419 B77G
AIR 6419 B78Y
Table 7
AIR 6419 Weight
Product
Weight (kg)(1)
AIR 6419 B40
29.5 kg
AIR 6419 B41
29.5 kg
AIR 6419 B42
20.0 kg
AIR 6419 B77G
29.5 kg
AIR 6419 B78Y
22.0 kg
(1) The weight is given with ±5% accuracy.
Table 8
AIR 6419 Color
Part
Color Code
Body
NCS S 1002-B
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
9
Antenna Integrated Radio Unit Description
2.5
Operating Environment Table 9
AIR 6419 Normal Operating Environment Values
Condition
Value
Temperature
−40°C to +55°C
Solar radiation
≤ 1,120 W/m²
Relative humidity
2% to 100%
Absolute humidity
0.26 to 40 g/m³
(1)
(1) Depending on installation scenario, traffic load, and configuration, the product can, in the highest 10 °C temperature range, temporarily reduce the output power. This depends on the durations of the high ambient temperature.
2.6
Wind Load Table 10
AIR 6419 Maximum Wind Load at 42 m/s
Product
Front (N)(1)
Side (N)(1)
AIR 6419 B40
642
136
AIR 6419 B41
653
110
AIR 6419 B42
454
105
AIR 6419 B77G
420
147
AIR 6419 B78Y
461
121
(1) According to EN 1991-1-4 pole installed AIR.
2.7
Heat Dissipation AIR 6419 is convection cooled and designed for outdoor installation. Max heat dissipation is calculated using the following formula: Max Heat Dissipation = Max Power Consumption − Configured Output Power Heat dissipation can be calculated for different traffic loads using values from Power Consumption Data. For more information, see Power Consumption Calculations.
10
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Technical Data
2.8
Vibration AIR 6419 operates reliably during seismic activity as specified by test method IEC 60068-2-57 Ff. Table 11
AIR 6419 Seismic Vibration Activity
Characteristic
Value
Maximum level of RRS
50 m/s² within 2–5 Hz for DR=2%
Frequency range
1–35 Hz
Time history signal
Verteq II from earthquake standard ATIS 0600329.2014
AIR 6419 operates reliably during random vibration as specified by test method IEC 60068-2-64. Table 12
AIR 6419 Random Vibration Normal Operation
Characteristic
Value
ASD-level
0.3 m²/s³ on horizontal axes X and Y 0.2 m²/s³ on vertical axis Z
2.9
Frequency range
2–200 Hz
Time per test direction
30 minutes
Acoustic Noise AIR 6419 does not have active cooling components. It can emit low levels of acoustic noise when operating on low capacity. The sound pressure level when operating on low capacity is lower than 28 dBA at 1-meter distance for hemispherical distribution, and 25 dBA for spherical distribution.
2.10
Power Supply Characteristics This section describes the power supply requirements, power consumption, and circuit breaker recommendations for the AIR.
2.10.1
DC Power Supply Characteristics AIR 6419 is designed for DC-I (3-wire) power connections used on DC-I (3-wire) sites. For DC-C (2-wire) power solutions, a DC-C (2-wire) connector is used. The following is a list of the power supply requirements:
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
11
Antenna Integrated Radio Unit Description
Nominal Voltage Operating Voltage Range Non-destructive Range
−48 V DC −36.0 to −58.5 V DC 0 to −60 V DC
Fuse and Circuit Breaker Recommendations The recommendations given in this section are based on peak power consumption, and they give no information on power consumption during normal operation. The recommended melting fuse type is am-gL-gG, according to IEC 60269-1. Circuit breakers must comply with at least Curve 3 tripping characteristics, according to IEC 60947-2. The AIR has a built-in Class 1 (Type 1) SPD to protect the equipment in case of lightning and network transients. The recommended fuse or circuit breaker rating is therefore dimensioned to not trip the fuse or circuit breaker in case of SPD operation. Table 13
AIR 6419 Fuse and Circuit Breaker Recommendations
Product
Output Power
Maximum Load Current at −36 V DC
Maximum Allowed Fuse Rating(1)
AIR 6419 B40
320 W
40 A
50 A
AIR 6419 B41
320 W
40 A
50 A
AIR 6419 B42
320 W
40 A
50 A
AIR 6419 B77G
320 W
40 A
50 A
AIR 6419 B78Y
320 W
40 A
50 A
(1) The maximum allowed fuse rating must (with a certain safety margin 10-20%) be larger than the maximum load current for reliable operation. However, it must not be larger than the next or nearest higher fuse or circuit breaker standard value in order to minimize the cable crosssection area and at the same time fully comply with relevant safety standards.
2.10.2
Power Consumption For information on power consumption, see Power Consumption Calculations and Power Consumption Data.
2.11
RF Electromagnetic Field Exposure For general information on RF EMF exposure, see Radio Frequency Electromagnetic Fields. The tables list the compliance boundaries (exclusion zones), outside of which the RF EMF exposure from AIR 6419 is below the limits specified by the ICNIRP, and the limits applicable in: — EU (1999/519/EC, 2013/35/EU, EN 50385) Table 14
12
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Technical Data
— USA (47 CFR 1.1310) Table 15 — USA (53 CFR 1.1310) Table 16 Information is provided for the theoretical maximum exposure condition and for the actual maximum exposure condition (see IEC 62232). The theoretical maximum exposure condition does not consider how the time-averaged power is distributed within the scan range of the product and is very conservative. The actual maximum exposure condition takes into account the effects of beam scanning on the time-averaged power that contributes to the RF exposure. A Power Reduction Factor (PRF) of 0.32 was used to represent realistic deployment scenarios (see IEC TR 62669). Note:
National regulations can prescribe requirements on the use of actual maximum exposure conditions for RF EMF compliance assessments.
Table 14 Dimensions of the Box-Shaped Compliance Boundary for General Public (GP) and Occupational (O) Exposure Applicable in the EU and Markets Employing the ICNIRP RF Exposure Limits Mode and Output Power
Dimensions of the Box-Shaped Compliance Boundary(1)(2) (m) Distance in Front of AIR
Width
Height
Distance Behind AIR
Prod uct
Standard
Maximu m Nominal Output Power from the AIR
IEC 62232 Installati on Class
Power Toleranc e
TDD DL Duty Cycle
Exposure Condition
GP
O
GP
O
GP
O
GP
O
AIR 6419 B40
LTE
320 W
E+
1.5 dB
75%
Theoretic al Maximu m
23.0
10.3
27.2
12.2
12.4
5.6
0
0
Actual Maximu m (PRF = 0.32)
13.9
6.3
15.8
7.1
7.3
3.3
0
0
Theoretic al Maximu m
25.7
11.5
31.0
13.9
14.0
6.3
0
0
Actual Maximu m (PRF = 0.32)
14.5
6.5
17.6
7.9
8.0
3.6
0
0
Theoretic al Maximu m
24.0
10.8
27.8
12.5
11.8
5.3
0
0
Actual Maximu m (PRF = 0.32)
14.5
6.5
16.1
7.2
7.0
3.2
0
0
Theoretic al Maximu m
26.9
12.0
31.8
14.2
13.4
6.0
0
0
AIR 6419 B40
AIR 6419 B41
AIR 6419 B41
NR
LTE(3)
NR
320 W
320 W
320 W
E+
E+
E+
1.5 dB
1.0 dB
1.0 dB
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
75%
75%
75%
13
Antenna Integrated Radio Unit Description
Mode and Output Power
Prod uct
AIR 6419 B42
AIR 6419 B42
AIR 6419 B78Y
AIR 6419 B78Y
Standard
LTE
NR
Maximu m Nominal Output Power from the AIR
320 W
320 W
LTE
320 W
Actual Maximu m (PRF = 0.32)
15.5
NR
320 W
Dimensions of the Box-Shaped Compliance Boundary(1)(2) (m)
IEC 62232 Installati on Class
E+
E+
E+
E+
Power Toleranc e
1.0 dB
1.0 dB
1.0 dB
1.0 dB
TDD DL Duty Cycle
75%
75%
75%
75%
Distance in Front of AIR
Width
Height
Distance Behind AIR
Exposure Condition
GP
O
GP
O
GP
O
GP
O
Actual Maximu m (PRF = 0.32)
15.2
6.8
18.0
8.1
7.6
3.4
0
0
Theoretic al Maximu m
25.4
11.4
29.5
13.2
11.7
5.3
0
0
Actual Maximu m (PRF = 0.32)
15.2
6.8
17.1
7.7
6.9
3.1
0
0
Theoretic al Maximu m
28.4
12.7
33.7
15.1
13.2
5.9
0
0
Actual Maximu m (PRF = 0.32)
16.1
7.2
19.1
8.6
7.5
3.4
0
0
Theoretic al Maximu m
25.7
11.5
29.9
13.4
11.8
5.3
0
0
7.0
17.3
7.8
7.0
3.2
0
0
Theoretic al Maximu m
29.8
13.3
33.6
15.0
13.4
6.0
0
0
Actual Maximu m (PRF = 0.32)
16.9
7.6
19.0
8.5
7.6
3.4
0
0
(1) The compliance boundaries are determined for maximum output power with power tolerance and TDD downlink duty cycle included, and for theoretical maximum and actual maximum exposure conditions. (2) For LTE, the compliance boundaries are determined for 75% of the power allocated to traffic beams and 25% to the broadcast beam. For actual maximum power conditions, the PRF of 0.32 was applied only to the power fraction allocated to traffic beams. (3) For NR+LTE mixed mode, the results for NR apply.
14
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Technical Data
Table 15 Dimensions of the Box-Shaped Compliance Boundary for General Public (GP) and Occupational (O) Exposure Applicable in the USA and Markets Employing the FCC Exposure Limits Dimensions of the Box-Shaped Compliance Boundary(1)(2) (m)
Mode and Output Power
Distance in Front of AIR
Width
Height
Distance Behind AIR
Produ ct
Standard
Maximum Configure d Output Power from the AIR
IEC 62232 Installatio n Class
Power Tolerance
TDD DL Duty Cycle
GP
O
GP
O
GP
O
GP
O
AIR 6419 B41
LTE(3)
60 W
E+
1.0 dB
75%
10.4
4.7
12.1
5.4
5.2
2.3
0.2
0.2
80 W
E+
1.0 dB
75%
12.0
5.4
13.9
6.3
5.9
2.7
0.2
0.2
120 W
E+
1.0 dB
75%
14.7
6.6
17.1
7.7
7.3
3.3
0.2
0.2
160 W
E+
1.0 dB
75%
17.0
7.6
19.7
8.8
8.4
3.8
0.2
0.2
240 W
E+
1.0 dB
75%
20.8
9.3
24.1
10.8
10.3
4.6
0.2
0.2
320 W
E+
1.0 dB
75%
24.0
10.8
27.8
12.5
11.8
5.3
0.2
0.2
60 W
E+
1.0 dB
75%
11.7
5.2
13.8
6.2
5.8
2.6
0.2
0.2
80 W
E+
1.0 dB
75%
13.5
6.0
15.9
7.1
6.7
3.0
0.2
0.2
120 W
E+
1.0 dB
75%
16.5
7.4
19.5
8.7
8.2
3.7
0.2
0.2
160 W
E+
1.0 dB
75%
19.0
8.5
22.5
10.1
9.5
4.3
0.2
0.2
240 W
E+
1.0 dB
75%
23.3
10.4
27.5
12.3
11.6
5.2
0.2
0.2
320 W
E+
1.0 dB
75%
26.9
12.0
31.8
14.2
13.4
6.0
0.2
0.2
AIR 6419 B41
NR
(1) The compliance boundaries are determined for maximum output power with power tolerance and TDD downlink duty cycle included. (2) For LTE, the compliance boundaries are determined for 75% of the power allocated to traffic beams and 25% to the broadcast beam. (3) For NR+LTE mixed mode, the results for NR apply.
Table 16 Dimensions of the Box-Shaped Compliance Boundary for General Public (GP) and Occupational (O) Exposure Applicable in the USA and Markets Employing the FCC Exposure Limits Dimensions of the Box-Shaped Compliance Boundary(1) (m)
Mode and Output Power
Distance in Front of AIR
Width
Height
Distance Behind AIR
Produ ct
Standard
Maximum Configure d Output Power from the AIR
IEC 62232 Installatio n Class
Power Tolerance
TDD DL Duty Cycle
GP
O
GP
O
GP
O
GP
O
AIR 6419 B77G
NR
60 W
E+
1.5 dB
75%
13.4
6.0
16.0
7.2
6.3
2.8
0.2
0.2
80 W
E+
1.5 dB
75%
15.4
6.9
18.5
8.3
7.3
3.3
0.2
0.2
120 W
E+
1.5 dB
75%
18.9
8.5
22.6
10.1
8.9
4.0
0.2
0.2
160 W
E+
1.5 dB
75%
21.8
9.8
26.1
11.7
10.2
4.6
0.2
0.2
240 W
E+
1.5 dB
75%
26.7
12.0
32.0
14.3
12.5
5.6
0.2
0.2
320 W
E+
1.5 dB
75%
30.8
13.8
36.9
16.5
14.5
6.5
0.2
0.2
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
15
Antenna Integrated Radio Unit Description
(1) The compliance boundaries are determined for maximum output power with power tolerance and TDD downlink duty cycle included.
2.12
Software For information on software dependencies, see Supported Radio Capabilities.
2.13
Radio Configurations For information about available radio configurations, see Radio Node Configurations.
16
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Hardware Architecture
3
Hardware Architecture
C
D
B
A
E Ge23270A
Figure 3 AIR 6419 Parts Table 17
AIR 6419 Parts
Position
Component
A
Radome
B
Cooling fins
C
Handles
D
L-shape brackets
E
Connection interfaces
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
17
Antenna Integrated Radio Unit Description
A
B C
D Ge25180B
Figure 4 AIR 6419 B40 (R-state ≥ R1E), B41 Parts Table 18
18
AIR 6419 B40 (R-state ≥ R1E), B41 Parts
Position
Component
A
Radome
B
Cooling fins
C
L-shape brackets with integrated handles
D
Connection interfaces
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Installation Requirements
4
Installation Requirements AIR 6419 is designed for outdoor use, and it can be installed either on a pole, on a wall, on a mast, or on a tower. Pole clamps, brackets, mounting accessories and other installation material or equipment specified by Ericsson must be used and Ericsson installation instructions be complied with.
4.1
Outdoor Installation Environments to Avoid To ensure optimal operation, avoid the following: — Hot microclimates caused by, for example, heat radiated or reflected from dark, metallic or glass surfaces — Chimney mouths or ventilation system outlets Avoid radio interference by keeping the area in front of the antenna clear of the following: — Metal surfaces or objects such as ladders, cabinets, enclosures — Equipment generating electromagnetic fields, for example, electric motors in air conditioners or diesel generators
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
19
Antenna Integrated Radio Unit Description
AIR
Directional beams
No interfering objects in front of the AIR! Ge13022C
Figure 5 Objects to Avoid in Front of AIR 6419
4.2 A
Installation Alternatives B
C
D
Ge23268B
Figure 6 AIR 6419 Installation Alternatives
20
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Installation Requirements
Table 19
AIR 6419 Installation Alternatives
Installation Method
Description
A
Pole installation (pole with circular cross section)
B
Pole installation (pole with square cross section)
C
Pole installation (pole with 90° angle cross section)
D
Wall installation
Tilt and swivel are supported depending on mounting bracket. For information on valid mounting brackets, see Site Installation Products Overview.
4.3
Space Requirements Front View
>0.1
AIR/Antenna
>0.1
AIR
>0.3
Y >0.3
Heat source
Unit of measurement: m
Ge16197B
Figure 7 Space Requirements for AIR 6419 Distance Y depends on the heat dissipation from the source below AIR 6419 and the surrounding temperature. The distance must be large enough so that the maximum operating temperature limit is not exceeded.
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
21
Antenna Integrated Radio Unit Description
Table 20 Temperature Increase Due to Heat Source Below AIR 6419 at Different Distances Distance Y
Heat Dissipation from Source Below AIR 6419 350 W
500 W
950 W
1200 W
0.2 m
1°C
3°C
5°C
6°C
0.3 m
0°C
1°C
3°C
4°C
0.5 m
0°C
0°C
2°C
3°C
To ensure adequate airflow, do not enclose AIR 6419 in a box-like environment. AIR 6419 is installed with the cable connections facing down. Allow enough free space below AIR 6419 to ensure sufficient working space.
4.4
Painting Disclaimer Ericsson recommends to not paint the product as it can affect performance of the product. Ericsson applies limitations to the warranty and service contract if the product is painted. If the product is painted, the following commercial limitations apply: — Failure modes directly related to overheating because of painting are not valid for repair within the scope of the warranty or standard service contract. — Product failures related to paint contamination of components of the unit are not valid for repair within the scope of warranty or standard service contract. — When a painted unit is repaired, it might be restored to the standard color before being returned to the market. It is not possible to guarantee that the same unit is sent back to the same place. This is also valid for units repaired under a service contract. — For repairs within the warranty period or a standard service contract, the customer is charged the additional costs for replacing all painted parts of the unit or the complete unit. If adaptations are required, contact Ericsson for information.
22
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Interfaces
5
Interfaces A
G
H
I
B
C
D
E
F
J
1
2
K
Ge23272B
Figure 8 AIR 6419 Connection Interfaces, Optical Indicators, and Buttons Table 21
AIR 6419 Connection Interfaces
Position
Description
A
eCPRI 1
1
B
eCPRI 2
2
C
DIN 14 pin, following functions supported: —
RAE
—
EC light
—
External alarms
Marking
Connector Type
Illustration
LC (On SFP) with support for FullAXS
DIN 14 female connector
Note: If using more than one function, a Y-cable must be connected to the DIN 14
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
23
Antenna Integrated Radio Unit Description
Position
Description connector for each added function.
D
TX Monitor
E
−48 V DC power supply
F
Grounding
Connector Type
Illustration
SMA female connector
−48 V
Power connector
2 × 6 mm dual lug
Table 22
AIR 6419 Optical Indicators
Position
Marking
Indicator Name
G
Fault
H
Operational
I
Maintenance
J Note:
1,
2
Interface
After the radio power is switched on, it takes 20 to 30 seconds before the slow flashing (0.5 Hz) starts. The operational indicator only flashes once during this period.
Table 23
24
Marking
AIR 6419 Button
Position
Function
Description
K
Site test button
Controls site test operation before radio is connected to a baseband unit. For more information, see Perform Basic Stand-alone Radio Installation Check. Basic Stand-alone Radio Installation Check is supported for AIR 6419 B77G from R2 onwards.
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Interfaces
5.1
Optical Cable Interfaces The optical cable interfaces provide connections to optical cables for traffic and timing signals between AIR 6419 and a Baseband unit. An SFP is used to connect the optical cable to AIR 6419. Note:
There are different SFP modules for different products.
Only use SFP modules approved and supplied by Ericsson. For recommended SFP modules, see SFP Module Selector Guide.
5.1.1
eCPRI Interface AIR 6419 sets up connection with Baseband through eCPRI interface, an up to 25.8 Gbps Ethernet port.
5.2
DIN 14-Pin Interface The DIN 14-pin interface supports the following functions: — RAE — EC light — External alarms
5.2.1
RAE RAE is used to determine if the AAS unit has moved during a thunder storm, earthquake, or similar. The RAE unit is mounted on top of the AAS and measures four different properties: — Position — Antenna Azimuth — Mechanical Tilt — Antenna Mounting Height For the measurements, except for altitude measurement, satellite positioning systems are used. It means that the unit is dependent of free line of sight to several satellites to be able to work.
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
25
Antenna Integrated Radio Unit Description
5.2.2
EC Light The EC light function delivers communication signals and alarms between the optional PSU and AIR 6419.
5.2.3
External Alarms The external alarms function can be used to monitor alarms from sensors on external equipment, for example doors, lights, and others.
5.3
TX Monitor Interface (Optional) The TX monitor interface provides monitoring of output power and performance.
5.4
−48 V DC Power Supply Interface The −48 V DC power connection is made through a connector with a 3-wire (DCI) connection or a connector with a 2-wire (DC-C) connection. For power cable dimensioning, see Site Installation Products Overview. For determining which connector or junction box to use, see Table 24. Table 24
AIR 6419 −48 V DC Power Supply Connector or Junction Box
Cross-Sectional Area of Each Conductor (mm²)
Connector or Junction Box
10–16
Used with connector RNT 447 36/01 (3wire (DC-I)) or RNT 447 37/01 (2-wire (DC-C))
25
Used with junction box NTB 101 75/1
The power cable conductor has a wire for both the 0 V conductor and a wire for the −48 V DC conductor. All cables must be shielded. The shielding must be properly connected both to the power connector and to the grounding in the power supply equipment. If the shielding is not connected, the AIR 6419 overvoltage and lightning protection do not function properly.
5.5
Grounding Interface AIR 6419 must be grounded to protect it from overvoltage and lightning strikes.
26
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Interfaces
For more information about grounding principles, see Grounding Guidelines for RBS Sites.
5.6
Optical Indicators Optical indicators show the system status. For more information about the optical indicators, see Indicators, Buttons, and Switches.
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
27
Antenna Integrated Radio Unit Description
6
Standards and Regulations This section presents a brief overview of standards, regulatory product approval, and declaration of conformity for the radio. Declaration of Conformity "Hereby, Ericsson AB, declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU and 2011/65/EU."
6.1
Regulatory Approval The Radio System complies with the following market requirements: — European Union (EU) market requirements, Radio Equipment Directive (RED) 2014/53/EU The apparatus may include radio Transceivers with support for frequency bands not allowed or not harmonized within the EU. — Products containing radio Equipment outside North America and in countries not recognizing the CE-mark may be labeled according to national requirements or standards.
6.1.1
Environmental Standards Compliance The product complies with the following environmental standard: Europe — Restriction of Hazardous Substances in Electrical and Electronic Equipment (RoHS) Directive (2011/65/EU) bands not allowed or not harmonized within the EU.
6.1.2
Safety Standards Compliance In accordance with market requirements, the product complies with the following product safety standards and directives: International — IEC 62368-1
28
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Standards and Regulations
Europe — EN 50385 — EN 62368-1 USA — UL 62368-1 — FCC CFR 47 Part 1.1310 Canada — CAN/CSA-C22.2 No. 62368-1 — Health Canada Safety Code 6 6.1.2.1
Outdoor Specific Requirements The product complies with the following outdoor specific requirements: International — IEC 60529 (IP65) — IEC 60950-22 Europe — EN 60529 (IP65) — EN 60950-22 USA — UL 50E — UL 60950-22 Canada — UL 50E — CAN/CSA-C22.2 No. 60950-22
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
29
Antenna Integrated Radio Unit Description
6.1.3
EMC Standards Compliance The product complies with the following Electromagnetic Compatibility (EMC) standards: International — 3GPP TS37.114 Europe — ETSI EN 301 489-1 — ETSI EN 301 489-50 USA — FCC CFR 47 Part 15 B Canada — ICES-003
6.1.4
Radio Standards Compliance The product complies with the following radio standards: International — 3GPP TS37.145-1 — 3GPP TS37.145-2 Europe — ETSI EN 301 908-1 USA — FCC CFR 47 Part 2 — FCC CFR 47 Part 27 Canada — IC RSS-Gen
30
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
Standards and Regulations
— IC RSS-192
6.1.5
Marking To show compliance with legal requirements, the product is marked with the following labels: Europe — CE mark — WEEE symbol USA — FCC CFR 47 Part 15 Compliance Statement: “This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: •
This device may not cause harmful interference.
•
This device must accept any interference received, including interference that may cause undesired operation.”
— cETLus — FCC ID Canada — ISED IC-003 Compliance statement: “CAN ICES-3 (B)/NMB-3(B)” — cETLus — ISED Certification Number and HVIN (IC ID)
6.2
Other Standards and Regulations The standards and regulations in this section are not regulatory approved.
6.2.1
Spare Parts The product adheres to the Ericsson Serviceability and Spare Part Strategy.
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04
31
Antenna Integrated Radio Unit Description
6.2.2
Surface Quality The surface quality of AIR 6419 is according to Ericsson standard class A5 for the radome, top, front, and side covers, and A6 for the heat sink.
6.2.3
Vandal Resistance Unauthorized access is not possible without damaging the tamper proof warranty seal.
6.2.4
Materials All Ericsson products fulfill the legal, market, and Ericsson requirements regarding the following: — Material declaration — Materials' fire resistance, components, wires, and cables — Recycling — Restricted and banned material use
32
302/1551-LZA 701 6001/1 Uen Y | 2022-07-04