48 0 864KB
A380 TECHNICAL TRAINING MANUAL RAMP & SERVICING COURSE - M02 (RR Trent 900) ATA 35 Oxygen
This document must be used for training purposes only
Under no circumstances should this document be used as a reference
It will not be updated.
All rights reserved No part of this manual may be reproduced in any form, by photostat, microfilm, retrieval system, or any other means, without the prior written permission of AIRBUS S.A.S.
AIRBUS Environmental Recommendation Please consider your environmental responsability before printing this document.
A380 TECHNICAL TRAINING MANUAL
ATA 35 OXYGEN
LAY08521 - L1502T0
Oxygen System Presentation (1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
RAMP & SERVICING COURSE - M02 (RR Trent 900) ATA 35 Oxygen
TABLE OF CONTENTS
Jan 13, 2009 Page 1
A380 TECHNICAL TRAINING MANUAL
OXYGEN SYSTEM PRESENTATION (1) General
LAY08521 - L1502T0 - LM35P4000000001
The Oxygen is supplied to the crew and cabin passengers in case of sudden cabin depressurization. In addition, the oxygen is supplied to the crew members in case of smoke or dangerous gases in the cockpit.
RAMP & SERVICING COURSE - M02 (RR Trent 900) ATA 35 Oxygen
OXYGEN SYSTEM PRESENTATION (1)
Jan 13, 2009 Page 2
LAY08521 - L1502T0 - LM35P4000000001
A380 TECHNICAL TRAINING MANUAL
GENERAL RAMP & SERVICING COURSE - M02 (RR Trent 900) ATA 35 Oxygen
OXYGEN SYSTEM PRESENTATION (1)
Jan 13, 2009 Page 3
A380 TECHNICAL TRAINING MANUAL
OXYGEN SYSTEM PRESENTATION (1) Flight Crew Oxygen System The flight crew oxygen system has three sections: The oxygen storage, The oxygen distribution and The oxygen control and indicating.
Storage The flight crew oxygen is stored in a high-pressure oxygen cylinder. This cylinder is located in the upper avionics compartment and placed in a cradle. Optionally the flight crew oxygen system can carry up to four cylinders.
Distribution
LAY08521 - L1502T0 - LM35P4000000001
The oxygen supplies the flight crew stations through a distribution circuit. High pressure is reduced to low pressure by the pressure reducer/transmitter. Low pressure oxygen flows via the low pressure supply valve to the distribution manifold. Then, the manifold supplies the oxygen to the mask stowage boxes in the cockpit. Each mask stowage box has a full face quick donning mask.
Control and Indicating A pushbutton switch, located on the overhead panel, controls the low pressure supply valve. The status of the flight crew oxygen system (oxygen supply pressure, oxygen pressure in the cylinder, high pressure or low pressure warnings) is indicated on the DOOR/OXY page of the ECAM system display (SD).
RAMP & SERVICING COURSE - M02 (RR Trent 900) ATA 35 Oxygen
OXYGEN SYSTEM PRESENTATION (1)
Jan 13, 2009 Page 4
LAY08521 - L1502T0 - LM35P4000000001
A380 TECHNICAL TRAINING MANUAL
FLIGHT CREW OXYGEN SYSTEM - STORAGE ... CONTROL AND INDICATING RAMP & SERVICING COURSE - M02 (RR Trent 900) ATA 35 Oxygen
OXYGEN SYSTEM PRESENTATION (1)
Jan 13, 2009 Page 5
A380 TECHNICAL TRAINING MANUAL
OXYGEN SYSTEM PRESENTATION (1) Passenger Oxygen System The passenger oxygen system has three sections: The oxygen storage, The oxygen distribution and The oxygen control and indicating.
Storage The oxygen cylinders are installed on the right hand side of the forward cargo compartment. The standard configuration includes three cylinders and up to fifteen cylinders as an option.
Distribution The oxygen supplies the passenger masks through a distribution circuit. High pressure is reduced to low pressure by the pressure reducer/transmitters. Low-pressure oxygen flows via the oxygen regulator to the distribution lines connected to the masks.
LAY08521 - L1502T0 - LM35P4000000001
Control and Indicating The system can be automatically activated when the cabin altitude exceeds 14000ft, by the Cabin Pressure Control System (CPCS) (application hosted in CPIOM-Bs) through the Oxygen System Control Unit (OSCU), or directly by the altitude pressure switch as a back up. It can also be manually activated on crew action. The "SYS ON" indicator light comes on in both cases. A manual release tool triggers the oxygen container opening. The status of the passenger oxygen system (oxygen supply, oxygen pressure, high pressure or low pressure warnings) is indicated on the DOOR/OXY page of the ECAM System Display.
RAMP & SERVICING COURSE - M02 (RR Trent 900) ATA 35 Oxygen
OXYGEN SYSTEM PRESENTATION (1)
Jan 13, 2009 Page 6
LAY08521 - L1502T0 - LM35P4000000001
A380 TECHNICAL TRAINING MANUAL
PASSENGER OXYGEN SYSTEM - STORAGE ... CONTROL AND INDICATING RAMP & SERVICING COURSE - M02 (RR Trent 900) ATA 35 Oxygen
OXYGEN SYSTEM PRESENTATION (1)
Jan 13, 2009 Page 7
AIRBUS S.A.S. 31707 BLAGNAC cedex, FRANCE STM REFERENCE LAY08521 JANUARY 2009 PRINTED IN FRANCE AIRBUS S.A.S. 2009 ALL RIGHTS RESERVED AN EADS COMPANY