SISTEMA DE GESTIÓN DE CALIDAD REGISTRO DE DESVIACIÓN LOCAL "PEAKING" PROYECTO: "REPARACIÓN TANQUE SURGENCIA ESPA-02-3771" FECHA:
09-sep-14
LOCACION: Estación Paraíso
REGISTRO DE DESVIACIONES LOCALES Registro:
Código de aceptación / rechazo: API STD 650
Código de referencia: N/A
1. CRITERIOS DE ACEPTACIÓN / RECHAZO DE DESVIACIONES DESCRIPCIÓN: 7.5.4 Local Deviations Local deviations from the theoretical shape (for example, weld discontinuities and flat spots) shall be limited as follows: a. Deviations (peaking) at vertical weld joints shall not exceed 13 mm (1/2 in.) . Peaking at vertical weld joints shall be determined using a horizontal sweep board 900 mm (36 in.) long. The sweep board shall be made to the nominal radius of the tank. b. Deviations (banding) at horizontal weld joints shall not exceed 13 mm (1/2 in.) . Banding at horizontal weld joints shall be determined using a straight edge vertical sweep board 900 mm (36 in.) long. 2. REGISTRO DE MEDICIONES PEAKING
JUNTA
ELEMENTOS
MEDICIONES (mm)
FECHA
JV1
SR07-08/SR07-01
02-sep-14
JV2
SR07-01/SR07-02
02-sep-14
JV3
SR07-02/SR07-03
02-sep-14
JV4
SR07-03/SR07-04
03-sep-14
JV5
SR07-05/SR07-06
03-sep-14
JV6
SR07-06/SR07-07
03-sep-14
JV7
SR07-07/SR07-08
04-sep-14
A B C A B C A B C A B C A B C A B C A B C
1
2
3
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
CALIFICACIÓN
TOLERANCIA (mm)
ACEPTADA
13
OK
13
OK
13
OK
13
OK
13
OK
13
OK
13
OK
RECHAZADA
3. REPORTE FOTOGRÁFICO
OBSERVACIONES:
ELABORADO POR
REVISADO POR
REVISADO POR
FIRMA
NOMBRE
Juan Cepeda / Jorge Fiallos
Santiago Vera / Santiago Ortiz
Francisco Espín / Richard Iñiguez
CARGO
QA/QC MECÁNICO
FISCALIZACIÓN BUREAU VERITAS
SIPEC
FECHA
SISTEMA DE GESTIÓN DE CALIDAD REGISTRO DE DESVIACIÓN LOCAL "BANDING" PROYECTO: "REPARACIÓN TANQUE SURGENCIA ESPA-02-3771" FECHA:
09-sep-14
LOCACION: Estación Paraíso
REGISTRO DE DESVIACIONES LOCALES Registro:
Código de aceptación / rechazo: API STD 650
Código de referencia: N/A
1. CRITERIOS DE ACEPTACIÓN / RECHAZO DE DESVIACIONES DESCRIPCIÓN: 7.5.4 Local Deviations Local deviations from the theoretical shape (for example, weld discontinuities and flat spots) shall be limited as follows: a. Deviations (peaking) at vertical weld joints shall not exceed 13 mm (1/2 in.) . Peaking at vertical weld joints shall be determined using a horizontal sweep board 900 mm (36 in.) long. The sweep board shall be made to the nominal radius of the tank. b. Deviations (banding) at horizontal weld joints shall not exceed 13 mm (1/2 in.) . Banding at horizontal weld joints shall be determined using a straight edge vertical sweep board 900 mm (36 in.) long. 2. REGISTRO DE MEDICIONES PEAKING
ITEM
ELEMENTOS
FECHA
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
SR07-05/SR06-03 SR07-05/SR06-03 SR07-05/SR06-04 SR07-06/SR06-04 SR07-06/SR06-04 SR07-07/SR06-05 SR07-07/SR06-05 SR07-08/SR06-05 SR07-08/SR06-01 SR07-01/SR06-01 SR07-01/SR06-01 SR07-02/SR06-02 SR07-02/SR06-02 SR07-03/SR06-02 SR07-03/SR06-03
04-sep-14 02-sep-14 02-sep-14 02-sep-14 02-sep-14 02-sep-14 02-sep-14 02-sep-14 02-sep-14 02-sep-14 02-sep-14 02-sep-14 02-sep-14 02-sep-14 02-sep-14
MEDICIONES (mm)
A B C D E F G H I J K L M N O
1
2
3
TOLERANCIA (mm)
0 0 0 0 0 0 3 2 0 0 0 0 0 0 0
0 3 2 0 3 1 1 0 4 1 3 2 5 0 1
0 0 0 0 0 0 3 2 0 0 0 0 0 0 0
13 13 13 13 13 13 13 13 13 13 13 13 13 13 13
CALIFICACIÓN ACEPTADA OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK
RECHAZADA
3. REPORTE FOTOGRÁFICO
OBSERVACIONES:
ELABORADO POR
REVISADO POR
REVISADO POR
FIRMA
NOMBRE
Juan Cepeda / Jorge Fiallos
Santiago Vera / Santiago Ortiz
Francisco Espín / Richard Iñiguez
CARGO
QA/QC MECÁNICO
FISCALIZACIÓN BUREAU VERITAS
SIPEC
FECHA