50 0 2MB
KONE Motor
电梯EU行业线 2017年4月
KONE Motor Modernization Tachometer
Encoder
415mm
MX18 Encoder
MX06、07、11
Modernization Site Site
Machine Room (1.75m/s)
Machine Room Less (1.0m/s)
Modernization Site Site
Machine Room (1.75m/s)
Controller Cabinet & Motor
Encoder installation
• 创新
概要 Summary
1
Introduce
2
Commissioning
3
Performance
Introduce 1.
Controler Cabinet
2.
Encoder(Replace Tachometer )
3.
Friction wheel wear detecting device
4.
Door System
5.
LOP
6.
Travelling Cable & other Cables
Others are the same
Configuration Name
Model
Controler Cabinet CE1-AL2-B-4FXX-MX Cartop inspection MBT-CTIB-A-MX Box COP MBT-COP-K-MX
QTY
Remark
1
MCTC-PG-D1
1
MCTC-HCB-B
1
LOP
MBT-HOP-B-MX
Cable
MBT
1
Encoder
MBT-EC-MX
1
Sensor
MBT-LS-MX
1
Modernization 1:Controler Cabinet 有机房对控制柜无特殊要求,控制柜放置于 机房内,无机房可以采用底板更换的非标控 制柜,具体可根据现场尺寸设计。 The organic room has no special requirements for the control cabinet. The control cabinet is placed in the machine room. The machine room can be replaced with a non-standard control cabinet. The specific design can be based on the site 。 size
Modernization 2:Encoder This part needs to be replaced when the disc horse friction wheel structure traction machine is configured (the revolving is not used), because all the PG cards of our NICE3000new can not support the voltage of the tachometer, so we should replace it with the ABZ encoder (pulse 1024). Use encoder instead of Tachometer directly , Encoder Type is ABZ encoder , Pluse is 1024 .
注:此程序只能碟马摩擦轮结构
Modernization 3:Sensor
通过EE-SX 670P(PNP型光电开关)光电来记录实际电机的圈数,系 统记录每一圈反馈的编码器实际脉冲数,当摩擦轮磨损严重时,实际反馈 的每圈脉冲数变化,通过变化量进行判断提前预警。 The number of turns of the actual motor is recorded by EE-SX 670P (PNP type photoelectric switch) photoelectric. The system records the actual pulse number of the encoder fed back every turn. When the friction wheel wears seriously, the actual number of pulses per revolution changes. The amount of change is judged in advance.
4:Door System 调查几个现场一般采用门机用的是AMD系列马达还是直流型的,无法用 我司门机替代。相关门的信号用我司HCB-B与现场门机对接。此板支持 前后门控制,由于我司系统为高电平有效,需将光幕、开门到位、关门 到位通过HCB-B进行转换。 Investigating several sites generally uses AMD series motors or DC type for door machines, which cannot be replaced by our door machine. The signal of the relevant door is connected with the on-site door machine by our HCB-B. This board supports front and rear door control. Since our system is active high, we need to convert the light curtain, open the door and close the door in place through HCB-B.
Commissioning instructions 1、Parameter Parameter
Description
Remark
F1-25
Motor Type
1:Synchronous motor
F1-00
Encoder Type
2:ABZ Encoder
F1-01
Motor Rated Power
F1-02
Motor Ralted Voltage
F1-03
Motor Ralted Current
F1-04
Motor Ralted Frequency
F1-05
Motor Rated Speed
F0-01
Command Source Selection
1:Distance Control
F1-11
Auto-Turning
1:with-Load auto-turning
According to nameplate
Motor Nameplate Motor type
Rotate speed
Brake model
Power
Freque ncy
V
Brake Voltage Brake Hold Voltage
Speed
A
Roping
Commissioning 2、Process
Commissioning troubleshoot 3、Error Code ①Error 20 Please check below parameter Parameter Descrption F1-12 正向调谐线数 FJ-33 反向调谐线数 F1-24 KONE专用调谐使能 F8-31 编码器参考线数 F8-32 调谐时电流百分比 F2-25 Z信号软化复位使能 F2-31 软化复位次数 FJ-34 正传匀速线数 FJ-35 反向匀速线数 FJ-36 正向保留线数 FJ-37 反向保留线数
Instruction 调谐前确保此参数近似实际线数 电机调谐成功后自动获取 Bit10置1=1024 20000 150 Bit6置1=64 200
Remark
Default set Need to confirm
Obtained after tuning is completed
②E20 failure during tuning Please check if the Z signal is normal. It is recommended to use shielded wire .
Runing Perforamce