Receiver / Decoder DRP Family DRP 364, 373, 375, 385

Menu Guide

BLANKOM Digital GmbH — TecCenter — 31162 Bad Salzdetfurth — Germany — Tel. +49 (0) 5063 / 2711-0 — Fax +49 (0) 5063 / 2711-60 Menu Guide - Receiver / Decoder DRP Family Rev 1.0

Receiver / Decoder DRP Family DRP 364, 373, 375, 385 List Of Contents

General Operating Instructions.............................................. 3 Main Level Menu.................................................................. 4 Front End Menu DRP 364 - ASI............................................ 5 Front End Menu DRP 375 - COFDM ...................................... 5 Front End Menu DRP 373 - QPSK ......................................... 6 Front End Menu DRP 385 - QAM .......................................... 7 Decoder Menu ..................................................................... 8 Video / Audio Menu.............................................................. 9 Video / Audio Menu............................................................ 10 Additional Menu................................................................. 11 Communication Interface Menu ........................................... 12 Common Interface Menu / Time Menu / Info Menu ................ 13 Default Configuration (Factory Settings) ............................... 14 Logbook Entries................................................................. 15 Logbook Entries................................................................. 16 RS 232 Interface – Command Overview ............................... 17 RS 232 Interface – Command Syntax................................... 20 Ethernet Interface – Command Syntax................................. 20

Blankom Digital

Rev 1.0

Receiver / Decoder DRP Family DRP 364, 373, 375, 385 General Operating Instructions Operation with pushbuttons The device is operated via the front panel keypad, supported by alphanumerical information in a background illuminated LC display. Menus provide for adjusting and query parameters. Use the buttons to select menu items for parameter displaying and changing or, in the adjustment mode, to select certain parameters within a menu and to modify values or decimals. The arrows in the display show in which direction you can move within the menu level. To store the modification, press ENTER. The fallback menue appears automatically after 5 minutes without button operation or by presssing the buttons  and  simultaneously.

1381 MHz BBC Prime

5.1dB

Display of receiption frequency, C/N reserve and service name. (Ex. of QPSK-Receiver, display depending on DRP type)

Adjustment Mode You can only change parameters in the adjustment mode. Simultaneously press the arrow keys ⊳ and  hold them down while pressing 3 times ENTER. The adjustment mode deactivates automatically after 3 minutes without button operation or by pressing the ENTER button for more than 2 seconds.

Reset A Reset performs a restart of the software. The DRP is initialized and will start with the latest stored configuration of the customer. All stored parameters remain the same. Simultaneously press the arrow keys  and  and hold them down while pressing 3 times ENTER.

Preset A Preset performs a restart of the software with default settings. The DRP is initialized and will start with the configuration set by the factory. All stored parameters will be erased and set to default values! Simultaneously press the arrow keys  and  and hold them down while pressing 3 times ENTER.

Rev 1.0

Blankom Digital

3 / 20

Receiver / Decoder DRP Family DRP 364, 373, 375, 385 Main Level Menu

 54MBit/s BBC PRIME v DRP364-1N V2.13 (V1.07) v FRONT-END ASI

Fall back menu (depending on frontend type)

DRP type and options Software version application + (firmware ethernet option)

Depending on front end type

v DECODER v VIDEO/AUDIO v ADDITIONAL v COMMUNICATION INTERFACE v COMMON INTERFACE v DATE 25.10.04 TIME 20:12:53 v LOG SCRIPT  (example: DRP 364-1)

4 / 20

Blankom Digital

Rev 1.0

Receiver / Decoder DRP Family DRP 364, 373, 375, 385 Front End Menu DRP 364 - ASI

Main level

Level 2

54MBit/s BBC PRIME v FRONT-END ASI



v DECODER

54 MBit/s 188 Bytes

Input data rate and supported packet size

v INPUT RATE 54 Mbit/s

Selection input data rate

v PACKET SIZE 188 Bytes

Selection packet size

v TSID / ONID 0x044D / 0x0001

Transport stream ID and

[54] [72] Mbit/s

[188] [204] bytes

original network ID

Front End Menu DRP 375 - COFDM

Main level 594.0 MHz NDR FS NDS

Level 2

>24dB

v FRONT-END COFDM



v DECODER

594.0 MHz 8 MHz

Input frequency and channel bandwidth

v FREQUENCY 594.0 MHz

Selection input frequency

v CH BANDWIDTH 8 MHz

Selection channel bandwidth

v TSID / ONID 0x044D / 0x0001

Transport stream ID and

v BIT ERROR RATE = 10E-5 / 7 = BER >= 10E-7 / 9 = BER >= 10E-9 - = not active

ST

DRP 373 - QPSK Command AP

LNB

LNB22 SY ZF

Parameter

Description

?

Display SCPC transport stream ID and SCPC status

xxxx

Set SCPC transport stream ID

?

Display LNB setting

14

Set remote power supply to 14 V

18

Set remote power supply to 18 V

off

Deactivate remote power supply and control signal

on

22 kHz control signal on

off

22 kHz control signal off

?

Display configured sympol rate

xx.xxxx

Set symbol rate in MSymbol/s

?

Display configured input frequency

xxxx

Set input frequency in MHz

DRP 375 - COFDM Command CHBW COFDMPAR

Parameter

Description

?

Display configured channel bandwith

7

Set channel bandwith to 7 MHz

8

Set channel bandwith to 8 MHz

?

Polling COFDM transmission parameters

DRP 385 - QAM Command RF SY QAM

Rev 1.0

Parameter

Description

?

Display configured input fequency

xxx.x

Set input frequency in MHz

?

Display configured sympol rate

x.xxxx

Set symbol rate in MSymbol/s

?

Display configured QAM constellation size

xxx

Set QAM constellation size

Blankom Digital

17 / 20

Receiver / Decoder DRP Family DRP 364, 373, 375, 385 DRP Common Commands Command

Parameter

Description

&S

Display of all parameters (incl. DRP type and software version)

&W

Preset (restart with factory settings) ?

Display audio gain

AG

dec

Decrease audio gain

inc

Increase audio gain

AL

?

Display available audio language according to table ID

Xx

Selection of audio language by table ID

AM AS

AT

?

Polling audio mode

?

Display output aspect ratio

43

Set output aspect ratio to 4:3

+12dB to –6dB at 0,5dB steps -6dB to –30dB at 3dB steps

auto

Set output aspect ratio to original input aspect ratio

l/on

Audio test sound left on

l/off

Audio test sound left off

r/on

Audio test sound right on

r/off

Audio test sound right off

CAM

?

Display CAM system

CAVER

?

Display hardware version of CA board

CD

?

Polling UTC date (e.g.: 06,07,04)

CN

?

Polling C/N reserve in dB (calculated margin to BER 2.0E-4)

CNI

?

Display configured VPS CNI code

xxx

Set VPS CNI Code

CT

?

Polling UTC time (e.g.: 14,26,23)

?

Display echo status

on

Activate echo function

EC

off

Deactivate echo function

EV

?

Polling of actual and next event (event name + VPS start time)

ID

?

Display of DRP type

INVID

?

Polling of aspect ratio and resolution of MPEG input signal

?

Polling muting status of original encoded WSS line (line 23)

0

Removing of encoded original WSS line (line 23) during letterbox mode off

1

Removing of encoded original WSS line (line 23) during letterbox mode on

clear

Clear log script

xxx

Polling 20 log script entries starting from position xxx

LBXWSSMUTE

LS

MU

PA

?

Display status of muting function (h = enabled, l = disabled)

xxxx

Enable/Disable muting functions xxxx = [AFC][BER][PROC][CA] h = high (enable) / l = low (disable)

?

Listing of all services within multiplex with index, service ID and name

xxxx

Selection of a service via service ID

PAS

?

Display configured service with ID, name and ISO639 language descriptor

PIDS

?

Display of video PID / audio PID / teletext PID

PSI

?

Polling PSI table versions of PAT, SDT and PMT

?

Listing of all services within multiplex with name, ID, PMT-PID, Provider + PIDs of configured service

PT

18 / 20

Blankom Digital

Rev 1.0

Receiver / Decoder DRP Family DRP 364, 373, 375, 385 DRP Common Commands Command PZ

RD

Parameter

Description

?

Display status of test line generation

on

Test line generation off

off

Test line generation on

?

Display fall back delay of relay after alarm in seconds

xxxx

Set fall back delay of relay after alarm in seconds

?

Display configured signalling mode

RESET SM

Restart of application (configuration remains)

rem

Set signalling mode to REMOTE ALARM

kbb

Set signalling mode to KBB OPTION

01,00

Protocol termination: i.e. interface activities are terminated, interface distributor #1 takes over control.

xx, yy

Selects a DRP via an interface distributor xx= cabinet address, yy= receiver address. DRP sets the RTS line to ‘LOW’ for 2 seconds. The command is not acknowledged (01 OK or 02 ERROR).

?

Polling muting status and BER-LEDs (A B E P C F 5 7 9 ) A = AFC or AGC-MUTING / B=BER-MUTING / E=ERROR FLAG P = PROC.MUTING / C = CA / F = FAULT 5 = BER >= 1.0E-5 / 7 = BER >= 1.0E-7 / 9 = BER >= 1.0E-9 - = not active

?

Display status test pattern generation

on

Test pattern generation on

SR

ST

TB

off

Test pattern generation off

TSID

?

Polling transport stream ID and original network ID

TT

?

Display status teletext insertion

TX

on

Teletext insertion on

TXTLINES VERFE

VF

VP

off

Teletext insertion off

?

Polling used teletext lines field 1/2

?

Display hardware version of front end

?

Display output video norm

pal

Set output video norm to PAL

secam

Set output video norm to SECAM

ntsc

Set output video norm to NTSC

?

Display status data line 16 / VPS insertion

on

Data line 16 / VPS insertion on

VS

off

Data line 16 / VPS insertion off

WM

?

Display status WSS insertion

WS

on

WSS insertion on

off

WSS insertion off

Rev 1.0

Blankom Digital

19 / 20

Receiver / Decoder DRP Family DRP 364, 373, 375, 385 Option N - Ethernet Command

Parameter

Description

ETHFWVER

?

Display firmware version of ethernet module

?

Display configured gateway address

GATEADDR

xxx.xxx.xxx.xxx Set gateway address ?

IPADDR

Display configured IP address

xxx.xxx.xxx.xxx Set IP address ?

SUBADDR

Display configured subnet mask

xxx.xxx.xxx.xxx Set subnet mask

RS 232 Interface – Command Syntax General commands: Line Feed Carriage Return

ASCII 0A Hex ''Ctrl J'' ASCII 0D Hex ''Return ↵''

Command syntax: (case insensitive) command parameter (n byte) e.g.: TXON => setting the VBI teletext to ON (Enabled) e.g.: LSCLEAR => clear log script Reply syntax: acknowledgement command parameter (n byte) e.g.: AM?

=> 01 OK stereo

e.g.: CAM?

=> 01 OK Cryptoworks

Data is transmitted as: ''ASCII'' Valid commands are acknowledged with: ''01 0K'' Invalid commands are acknowledged with: ''02 Error'' Echofunction can be enabled/disabled.

Ethernet Interface – Command Syntax Protocol : The protocol used for the control over ethernet is UDP using port 4003. The command syntax is the same as used for the RS232 interface.

20 / 20

Blankom Digital

Rev 1.0