Page 1 of 2 Date: February 13, 2012
REV-01 TCSB.F2280.ASMBL.P
Fastenal Product Standard
Round Head Tension Control Structural Bolts, ASTM F2280, Type 1, Assembled The information below lists the required dimensional, chemical and physical characteristics of the fasteners in this purchase order. If the order received does not meet these requirements, it may result in a supplier corrective action request, which could jeopardize your status as an approved vendor. Unless otherwise specified, all referenced consensus standards must be adhered to in their entirety.
Nominal Size (inch)
1/2" 5/8" 3/4" 7/8" 1" 1 1/8"
E
D
H
Full Size Body Dia.
Head Dia.
Head Height
Max. 0.515 0.642 0.768 0.895 1.022 1.149
Nominal Size 1/2 5/8 3/4 7/8 1 1 1/8
Min. 0.482 0.605 0.729 0.852 0.976 1.098
Max. 1.126 1.313 1.580 1.880 2.158 2.375
F Width Across Flats Max. Min. .875 .850 1.062 1.031 1.250 1.212 1.438 1.394 1.625 1.575 1.812 1.756
Basic 5/16 25/64 15/32 35/64 39/64 11/16
Max. 0.323 0.403 0.483 0.563 0.627 0.718
G Width Across Corners Max. Min. 1.010 .969 1.227 1.175 1.443 1.382 1.660 1.589 1.876 1.796 2.093 2.002
Min. 0.302 0.378 0.455 0.531 0.591 0.658
LT
LS
S
Thread Length Basic
Length of Spline Ref.
Width Across Flats Spline Ref
Ref. 1.25 1.38 1.50 1.75 2.00
0.50 0.60 0.65 0.72 0.80 0.80
0.32 0.43 0.53 0.61 0.70 0.80
H Thickness Max. Min. .504 .464 .631 .587 .758 .710 .885 .833 1.012 .956 1.139 1.079
Page 2 of 2 Date: February 13, 2012
REV-01 TCSB.F2280.ASMBL.P
Fastenal Product Standard
Size 1/2 5/8 3/4 7/8 1 1 1/8
B Nominal 1.063 1.313 1.468 1.750 2.000 2.250
A Nominal .531 .688 .813 .938 1.063 1.188
C Min. .097 .122 .122 .136 .136 .136
Max. .177 .177 .177 .177 .177 .177
Specification Requirements: • •
• • • •
Dimensions: Material & Mechanical Properties:
Thread requirements: Head marking: Coating: Material Test Reports:
ASME B18.2.6. Heavy Hex Structural Bolt: ASTM F2280, Type 1. Heavy Hex Nut: ASTM A563 Grade DH. Structural Washer: ASTM F436. ASME B1.1 UNC Class 2A. Must have A490TC and manufacturer ID. Light protective oil. The MTR must have documented lot traceability, including full chemical and mechanical figures, to the specification(s) above.