STRUCTURAL STRENGTHENING DESIGN BASED ON TR55&EUROCODE 2. APRIL 2016, DAVID VAZQUEZ CACHO CORPORATE TECHNICAL DEPT. – SIKA SERVICES AG.
 
 DESIGN OF FRP INTRODUCTION
 
 DEVELOPMENT OF THE SIKA FRP SYSTEMS SIKADUR®30: LONG-TERM DURABILITY 1967:
 
 Sikadur®range developed as steel plate bonding for Structural Strengthening
 
 1970
 
 Long Term Test at EMPA Sikadur® -30 (not finished yet)
 
 Steel: long-term durability is critical as resulting of the risk of corrosion. From 90s, steel plates were progressively substituted by CFRP systems.
 
 4
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKA FRP PRODUCT RANGE CFRP RANGE DEVELOPMENT 1982: Tests of Carbon Fiber Reinforced Polymer (CFRP) Plates for Structural Strengthening of Reinforced Concrete
 
 Cyclic Load Test
 
 Climatic Test (heat+humidity)
 
 >50 test beams 1989 5
 
 April 2016
 
 PhD Thesis H.-P. Kaiser, EMPA, Switzerland
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKA FRP PRODUCT RANGE FIRST APPLICATION OF SIKA CFRP SYSTEMS 1991:
 
 First Application of Sika CFRP systems for Structural Strengthening of a bridge
 
 Ibach Bridge, Zurich (Switzerland) 6
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 INTRODUCION WHAT IS THE CFRP? Human hair (D=0,08mm)
 
 CARBON FIBERS
 
 EPOXY RESIN
 
 Carbon fiber (D=0,007mm)
 
 COMPOSITE = CFRP 7
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 FRP STRENGTH FIBERS COMPARISON ULTIMATE STRENGTH
 
 5000 MPa
 
 4000 MPa 3000 MPa DESIGN STRENGTH
 
 2000 MPa 1000 MPa
 
 STEEL Carbon
 
 8
 
 April 2016
 
 Basalt
 
 Glass
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 Aramid
 
 SIKA FRP PRODUCT RANGE MAIN FRP STRENGTHENING MATERIALS Prefabricated systems
 
 Manual application systems
 
 Sika Carbodur® CFRP plates Sika CarboShear L- links Sika CarboDur® range for NSM applications Sika CarboStress® post-tensioned CFRP system Sikadur® structural adhesives
 
 SikaWrap® fabrics SikaWrap® FX anchorages SikaWrap® Grid FRP meshes Sikadur® structural adhesives
 
 Prefabricated systems represent ≈80% of the current applications in Europe, as they are usually considered as a safer system (lower safety factors and less restrictions regarding the unevenness of the concrete surface, ) and higher efficiency during the installation process.
 
 10
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKA CARBODUR® PROJECT REFERENCES
 
 EDF, France
 
 12
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKA CARBODUR® LJUBLIANICA BRIDGE
 
 13
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKA CARBODUR® REAL MADRID F.C.
 
 14
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 CFRP STRENGTHENING OF BEAMS USUAL ARRANGEMENT A complete strengthening comprises the shear and flexural reinforcement of the member.
 
 Bending Carbon fiber laminates only work under tension. Hence, it´s necessary to determine the position of the tensile stresses along the element. The CFRP laminates are displayed longitudinally along the concrete´s surface. Shear External CFRP stirrups are displayed at the beam´s ends. The wrapping scheme can be either complete (full wrapping) or partial (U-wrapping or lateral display).
 
 15
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 CFRP STRENGTHENING OF BEAMS AS A SIMPLIFICATION:
 
 16
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 18
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 COLUMN CONFINEMENT POISSON´S EFFECT Due to the Poisson´s effect, the concrete is transversally expanded when compressed. This expansion leads to the collapse of the column, as concrete has a very limited capacity for elongation.
 
 Hence, if the transversal expansion is restricted, the final strength increases…
 
 19
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 COLUMN CONFINEMENT POISSON´S EFFECT To avoid the lateral expansion, its necessary to ensure a confinement around the element, by using a rigid material with a high strength. This material must keep the geometry of the member when it tries to expand.
 
 In case of strictly compressive loads alone (extremely unusual), the confinement allows surprising solutions:
 
 Gravel column?
 
 And water column?
 
 20
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKAWRAP® FABRICS DRY APPLICATION
 
 21
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKAWRAP® FABRICS DRY APPLICATION
 
 Sikadur®-330 Priming
 
 SikaWrap®
 
 22
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 Adhesive Saturant
 
 SIKAWRAP® FABRICS WET APPLICATION
 
 24
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKAWRAP® FABRICS WET APPLICATION
 
 Sikadur®-330 Priming
 
 Sikadur®-300 SikaWrap®
 
 25
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 Saturant
 
 TECNICAL REPORT 55, THIRD EDITION (2014) SOME DIFFERENCES WITH RESPECT TO OTHER EXISTING GUIDELINES
 
 FRP STRENGTHENING LIMITS TR55/EUROCODE2 Independently of any other mechanical limitation, the TR55 leads to certain restrictions before the design of the FRP: SERVICEABILITY LIMITS
 
 Reinforced Concrete Limits The effective stress for the reinforcing steel under service loads (characteristic combination) will remain below 80% of its yield point. 𝑓𝑦 ≤ 0.80 𝑓𝑦𝑘 THE EXISTING MEMBER MUST EXHIBIT A MINIMUM STRENGTH In the event that the FRP system is damaged, the structure will still be capable of resisting a reasonable level of load without collapse. The existing strength of the structure should be sufficient to resist a minimum level of load (frequent combination of service loads).
 
 In the event that the FRP system is damaged, the structure will still be capable of resisting a reasonable level of load without collapse. The existing strength of the structure should be sufficient to resist a minimum level of load (quasi-permanent combination of service loads). 27
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 FLEXURAL STRENGTHENING TR55/EUROCODE2 – SAFETY FACTORS Unlike other existing FRP codes, the TR55 uses a complex combination of 3 safety factors for the design, taking into account:  
 
 The kind of FRP material. The kind of application method.
 
 The design parameters affected in the design of the FRP are:   
 
 The ultimate admissible deformation. The ultimate design strength. The E-modulus of the FRP system.
 
 28
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 FLEXURAL STRENGTHENING TR55/EUROCODE2 – SAFETY FACTORS
 
 EXAMPLE 1: CARBODUR S: ACI440: 170GPa
 
 TR55: 165GPa / (1.1 x 1.05)= 142 Gpa (84%)
 
 EXAMPLE 2: SIKAWRAP 230C (BASED ON DRY THICKNESS): ACI440: 225GPa
 
 29
 
 April 2016
 
 TR55: 220GPa / (1.1 x 1.20)= 166 GPa (73%)
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 FLEXURAL STRENGTHENING
 
 FLEXURAL STRENGTHENING DESIGN OF THE FRP STRENGTHENING (1) The calculation follows the standard mechanical principles (forces equilibrium and compatibility of deformations in the section among the different materials), except for the following 2 issues: 1) The section to calculate will exhibit an existing deformation prior to the strengthening, which must be considered for the design. This event may affect significantly the serviceability limits of the strengthened member. 2) The reduced FRP E-modulus will be taken into account (TR55 criteria) 0,35%
 
 Ff
 
 31
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 FLEXURAL STRENGTHENING DESIGN OF THE FRP STRENGTHENING (2) The ultimate strength of the strengthened member will be defined by one of the following limitations:  Concrete crushing under compression (0,35% deformation for European codes).  FRP rupture (not expected for systems based on CFRP, but possible in case of using GFRP laminates).  Debonding of the FRP laminate from the substrate as a consequence of :
 
 FRP separation induced by the presence of shear cracks
 
 32
 
 April 2016
 
 Debonding due to lap-shear forces along the span.
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 Debonding due to an insufficient anchorage length.
 
 FLEXURAL STRENGTHENING DESIGN IN CASE OF NSM
 
 33
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 FLEXURAL STRENGTHENING DEBONDING DUE TO LONGITUDINAL SHEAR STRESS ALONG THE SPAN – TR55 The TR55 follows the same principle as fib14; the longitudinal shear stress is evaluated between consecutive sections. The main differences are: a)The longitudinal shear strength of the concrete substrate is limited according to the location of the section: 𝝉𝒍𝒊𝒎 = 𝟒, 𝟓 𝝉𝒍𝒊𝒎 = 𝟎, 𝟖
 
 𝒇𝒄𝒕𝒌 𝟏,𝟓 𝒇𝒄𝒕𝒌 𝟏,𝟓
 
 (TR55, yield zone of the span) (TR55, elastic region between anchorage zone and yield zone)
 
 b)The TR55 includes an additional longitudinal stress 𝝉𝒔𝒄 corresponding to the positions of flexural cracks. 𝝉𝒔𝒄 = 𝟕, 𝟖 𝟏. 𝟏 −
 
 𝑴𝒚
 
 𝑴𝑬𝒅
 
 𝒇𝒄𝒕𝒌 𝝉𝒔𝒄+𝝉𝒃 ≤ 𝝉𝒍𝒊𝒎
 
 B
 
 Original moment capacity
 
 Steel yielding 1-Anchorage 2-Elastic region
 
 3-Yield region
 
 Nf,B
 
 A ΔNf τb τsc
 
 Nf,A
 
 FLEXURAL STRENGTHENING DEBONDING IN THE ANCHORAGE ZONE
 
 The evaluation of the end-anchorage comprises 3 steps: Step 1- Determination of the critical section from which the anchorage shall be provided Step 2- Determination of the maximum anchorage length and the maximum force that can be anchored. Step 3- In case the length available for the anchorage is inferior than the maximum, the maximum force that can be anchored must be calculated according to the existing length.
 
 FLEXURAL STRENGTHENING STEP 1 – DETERMINATION OF THE CRITICAL SECTION Fib14 (simply supported) The critical section corresponds to the outermost flexural crack of the strengthened section (shift rule according to Eurocode must be considered).
 
 Mcr - Cracking moment
 
 Anchorage length
 
 ACI440(simply supported)
 
 The critical section is point along the span corresponding to the cracking moment of the strengthened section.
 
 Mcr - Cracking moment
 
 Anchorage length
 
 TR55 (simply supported) The critical section corresponds to the point where the CFRP is no longer required. Anchorage length
 
 Mcr - Cracking moment Original moment capacity
 
 FLEXURAL STRENGTHENING STEP 2 – DETERMINATION MAXIMUM ANCHORAGE LENGTH AND MAXIMUM FORCE THAT CAN BE ANCHORED TR55
 
 FIB14
 
 ACI 440.2R-08
 
 The force that can be anchored increases with increasing anchorage length lt but there is a treshold anchorage length lt max above which no increase in the bond failure force is possible. F=1
 
 F=2
 
 lt
 
 F=3
 
 lt ltmax
 
 ltmax
 
 F=3
 
 lt
 
 lt
 
 ltmax
 
 ltmax
 
 ?
 
 The maximum force that can be anchored is determined as: 𝑇𝑘,𝑚𝑎𝑥 = 0,5 𝑘𝑏 𝑏𝑓 √(𝐸𝑓𝑑 𝑡𝑓 𝑓𝑐𝑡𝑘 )
 
 𝑁𝑓𝑎,𝑚𝑎𝑥 = 0,576 𝑘𝑏 𝑏𝑓 √(𝐸𝑓 𝑡𝑓 𝑓𝑐𝑡𝑚 )
 
 ?
 
 ~50% more ! The maximum anchorage length is: 𝑙𝑡,𝑚𝑎𝑥
 
 𝐸𝑓𝑑 𝑡𝑓 = 0,7 𝑓𝑐𝑡𝑘
 
 𝑙𝑡,𝑚𝑎𝑥 =
 
 𝐸𝑓 𝑡𝑓 2 𝑓𝑐𝑡𝑚
 
 𝑙𝑑𝑓 =
 
 𝑛𝐸𝑓 𝑡𝑓 𝑓´𝑐
 
 FLEXURAL STRENGTHENING SUMMARY TR55 shows a complex design methodology: the effective CFRP strain is not significantly restricted, but many verifications concerning intermediate debonding or end anchorages are necessary. The debonding possibility may force to increase the bonding surface in contact with the concrete, leading to wider/larger FRP schemes than the initially necessary.
 
 COLUMN CONFINEMENT
 
 COLUMN CONFINEMENT PERFORMANCE OF THE FRP CONFINEMENT If the lateral expansion is constrained by means of a rigid material, the concrete will be able to take additional axial loads. This can be represented graphically as follows:
 
 Compressive Stress
 
 Original concrete. Peak Stress corresponds to 0,2% deformation, ultimate strain 0,3%-0.35% (ACI/European codes). Confined concrete. The enhanced peak stress remains at 0.2% deformation. The ductility is significantly increased Heavily confined concrete. Performance at 0.2% deformation is enhanced. However, the concrete is still capable to assume additional load. Ultimate load is higher than peak load. 0,2% 0,3% 0,35%
 
 Axial deformation
 
 Hence, the performance of the confined concrete depends on the confinement force exerted by the CFRP jacket:
 
 43
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 44
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 COLUMN CONFINEMENT INFLUENCE OF THE COLUMN´S GEOMETRY CIRCULAR SECTIONS For a circular section, the confining pressure affects the entire section. Due to this, the efficiency of the strengthening system is significantly high.
 
 SQUARE SECTIONS For a square section, a parabolic arching action is assumed for the concrete core where the confining pressure is fully developed. Unlike a circular section, part of the cross-section remains unconfined. 46
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 COLUMN CONFINEMENT INFLUENCE OF THE COLUMN´S GEOMETRY RECTANGULAR SECTIONS Due to the arching effect, a significant part of the crosssection may remain unconfined. In case of long shapes, the area corresponding to the confined core may result very small (aspect ratio> 2:1)
 
 ROUNDING OF CORNERS The rounding of the corners alters the parabolic arching effect, increasing the area corresponding to the confined core. This also reduces the risk of failure of the CFRP, as most of the tensions are located in the edges of the RC 47
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 COLUMN CONFINEMENT BASIS OF THE CALCULATION TR55
 
 ACI 440.2R-08
 
 FIB14
 
 The confinement pressure is the main parameter to evaluate the resulting strengths of the confined column. The confinement pressure exerted by a circular column is calculated as: 𝑓𝑙 = 2 𝑡𝑓 𝜀𝑓,𝑟𝑢𝑝 𝐸𝑓 /𝐷, where D corresponds to the diameter of the column. However, the key parameter is the admissible deformation of the CFRP jacket under this conditions, 𝜀𝑓,𝑟𝑢𝑝 , which is limited as: 𝜀𝑓,𝑟𝑢𝑝 = 0,40 𝜀𝑓𝑢
 
 𝜀𝑓,𝑟𝑢𝑝 = 0,47 𝜀𝑓𝑢 𝑒𝑥𝑡𝑒𝑟𝑖𝑜𝑟 𝑒𝑥𝑝𝑜𝑠𝑢𝑟𝑒 𝜀𝑓,𝑟𝑢𝑝 = 0,52 𝜀𝑓𝑢 𝑖𝑛𝑡𝑒𝑟𝑖𝑜𝑟 𝑒𝑥𝑝𝑜𝑠𝑢𝑟𝑒
 
 Undefined: “…proper values should be justified by experimental evidence…”
 
 TR55 and ACI440 lead to safe magnitudes.
 
 However, the absence of clear limitations in the FIB14 guideline may guide to unsafe calculations !!
 
 48
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 COLUMN CONFINEMENT WRONG FRP ARRANGEMENTS.
 
 52
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SHEAR STRENGTHENING
 
 SHEAR STRENGTHENING INTRODUCTION Unlike the design of flexural strengthening, where standard mechanical criteria govern de calculations, the complexity of the shear mechanisms forced the development of design methods from experimental researches. Independently from the calculation procedure used, the shear strength of the member is determined as the sum of the strengths provided by the steel and CFRP separately (and concrete in ACI-based codes).
 
 54
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SHEAR STRENGTHENING CFRP CONFIGURATIONS
 
 However, certain criteria is common among the different design methods: 
 
 The CFRP is dimensioning following similar procedures than those used for the calculation of internal steel stirrups.
 
 
 
 The CFRP can be displayed following 3 different configurations: Full wrapping, providing the best performance. “U” wrapping of the beam. Bonded on both sides of the beam. This scheme provides the worst performance.
 
 55
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SHEAR STRENGTHENING CFRP CONFIGURATIONS
 
 Additionally, 2 more FRP schemes are possible
 
 
 
 Shear strengthening with NSM profiles (included in TR55). Due to the design approach, this alternative is not efficient in case of beams with small height.
 
 
 
 Shear strengthening with CarboShear L links (Empa report adapted to TR55 approach). Due to the TR55 limitations concerning the maximum spacing between consecutive CFRP profiles, this option may lead to oversized results.
 
 56
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 OTHER SIKA FRP SOLUTIONS
 
 CARBOHEATER® PATENTED PRINCIPLE. Substrate
 
 Brack et
 
 Temp. gauge
 
 CFRP plate
 
 0 - 100V DC Heating device
 
 Brack et
 
 Power supply 3x400V/16A
 
 • Electric resistance (R) of CarboDur® plates • Apply electric current (I) • Heating power: P = R x I2 60
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 CARBOSHEAR® PATENTED PRINCIPLE.
 
 62
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 CARBOSHEAR® PATENTED PRINCIPLE.
 
 63
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 NSM SYSTEMS SIKA NEAR SURFACE MOUNTED SYSTEMS 1. Cut groove in concrete cover of internal reinforcement 2. Fill with Sikadur®-30/330/300 adhesive 3. Place CarboDur® S plate / CarboDur® BC rod
 
 concrete cover
 
 internal steel reinforcement
 
 65
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 NSM SYSTEMS MAIN ADVANTAGES
 
     
 
 Not exposed to mechanical damage Invisible strengthening Confined from 3 sides, no surface delamination of concrete Short end anchorage length No buckling – suitable for compression zone and compressed members  earthquake loaded frames with change of direction of flexure
 
 66
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKAWRAP FX-50C OVERVIEW  SikaWrap® FX-50C  Dry Carbon Fibre string  Encased in plastic sleeve  USES:  End anchorage of SikaWrap® fabrics  Flexible near surface reinforcement
 
 67
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKAWRAP FX-50C IMPROVED FABRIC ANCHORAGE  SikaWrap FX installed into beam  Spread in slits on beam surface
 
  SikaWrap FX installed into top slab  Spread in slits on beam surface
 
  SikaWrap FX installed in inner corner  Spread in slits on beam surface 68
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKAWRAP FX-50C IMPROVED FABRIC ANCHORAGE
 
 CFRP Anchors
 
 69
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKAWRAP FX-50C IMPROVED FABRIC ANCHORAGE: INSTALLATION
 
 70
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 FLEXIBLE NSM SIKAWRAP FX-50C
 
 71
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 TRM SYSTEMS TEXTILE REINFORCED MORTAR
 
 Compatible to brick, stone, concrete Water vapour permeable
 
 Avoid out-of-plane failure
 
 72
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 TRM SYSTEMS MAIN ADVANTAGES  Water vapour permeable mortar, suitable for full-surface application on masonry walls in buildings  Uneven substrate (PCC mortar instead of epoxy mortar for levelling)  Similar E-modulus of mortar to substrate, similar stiffness, no delamination  Weak substrate (tamped concrete), where high strength of epoxy can not be used  Application on damp/wet substrate  Wet-spray application
 
 73
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKAWRAP® 350G GRID INSTALLATION
 
 SIKA TRM main advantages -Can be installed even on weak or wet substrates -Fits on rough, curved or irregular surfaces -High water vapour permeability -Easy anchorage using SIKAWRAP ANCHOR C.
 
 74
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 CARBOSTRESS® SIKA POST-TENSIONED CFRP SYSTEM
 
 75
 
 
 
 Core drilling, block out, concrete surface
 
 
 
 
 
 Steel reaction frames
 
 
 
 Cut CarboDur® plate to length
 
  Place CarboStress® tendon, Hydraulic jack
 
 
 
 Mount CarboStress® anchors
 
 
 
 Temporary support
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 Sikadur®-30 / 30 LP
 
   
 
 Prestress Remove hydraulic jack Fill with Sikadur®-41 / 42
 
 
 
 Remove temporary support
 
 CARBOSTRESS® REACTION FRAMES ADAPTED TO THE PROJECT Live End Fix End
 
 Negative deviation
 
 76
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 FIRE SITUATION / ELEVATED TEMPERATURE
 
 ELEVATED TEMPERATURE GLASS TRANSITION TEMPERATURE …for a dry environment, it is generally recommended that the anticipated service temperature of an FRP system not exceed Tg-15ºC
 
 ACI 440: HIGH SERVICE TEMPERATURES:
 
 Sikadur® 30 LP 120
 
 100
 
 80 Curing Temp.
 
 60
 
 Tg 40
 
 20
 
 0 1
 
 79
 
 April 2016
 
 2
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 3
 
 ELEVATED SERVICE TEMPERATURE HIGH RISE INDUSTRIAL CHIMNEY, SWITZERLAND
 
 Built 1902 Height 40m Diameter 3.20m 80
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 ELEVATED SERVICE TEMPERATURE INSTALLATION IN BRIDGE DECK (HOT ASPHALT)
 
 81
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 82
 
 ELEVATED SERVICE TEMPERATURE INSTALLATION IN BRIDGE DECK (HOT ASPHALT) Torched bitumen membrane / Hot – asphalt (approx. 240°C) Optional: Sikadur®-186 Epoxy-primer or primer Sikafloor®-82 EpoCem® self – levelling, 4-7 mm
 
 SikaTop® Armatec®-110 EpoCem® or EpoCem®-Modul (full-surface primer)
 
 Sikadur®-30 / Sikadur®-330 sanded with fire-dried quartz sand CarboDur® CFRP plate Sikadur®-30 Bridge Deck 82
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 FIRE SITUATION INTRODUCTION 2 resistances are related to the fire scenario. Their limits and designation are strongly dependent of the local regulations in each country. 1-Reaction to fire is the measurement of how a material or system will contribute to the fire development and spread, as well as the emission of smoke/flaming droplets. According to their use, certain quantity and/or type of materials cannot be used for walls/floor/ceiling rendering. Concrete and steel do not contribute to the fire development, and do not generate smoke. Due to the polymer content of the CFRP and the adhesives, the reaction to fire of the strengthening system is moderate. However, under most of the circumstances, the global influence is negligible due to the limited surface covered by the laminates. 2-Fire resistance of the structural member: The load bearing capacity of the member can be assumed for a specific period of time (30 to 240 minutes usually). The fire resistance is expected to provide time to the building occupants for emergency evacuation before the structure collapses. Hence, the requested time to resist is commonly proportional to the quantity of people to evacuate and the distance to the exit.
 
 83
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 Requested fire resistance
 
 240 ´
 
 30´ BUILDING´S USE
 
 Hospital
 
 84
 
 April 2016
 
 Commercial
 
 Educational
 
 Administrative
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 Residential
 
 DISTANCE TO EXIT
 
 Skyscraper
 
 Building
 
 Detached House
 
 DECREASE OF CONCRETE STRENGTH IN CASE OF FIRE
 
 85
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 DECREASE OF STEEL STRENGTH IN CASE OF FIRE
 
 86
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 TEMPERATURE RESISTANCE SIKADUR 30
 
  PhD Thesis 2009 Ernst-Lucas Klamer, TU Eindhoven  Sika CarboDur / Sikadur-30
 
 87
 
 Design and protection of CFRP in case of fire – Only for internal use.
 
 TEMPERATURE RESISTANCE SIKADUR® 30 ADHESIVE, LAP SHEAR TEST.
 
   
 
 88
 
 No significant decrease in lap shear strength up to 80°C (Tg + 20°C) Slight decrease at 100°C (Tg + 40°C) for normal strength concrete Short term tests (15 min)
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 TEMPERATURE RESISTANCE SIKADUR® 30 ADHESIVE, 3-POINT BENDING TEST.
 
  
 
 89
 
 No significant decrease in failure load up to 90°C (Tg + 30°C) for normal strength concrete Short term test
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKACRETE® 213 PROTECTION MORTAR 50MM SIKACRETE®-213F 100.0
 
 40mm
 
 Temperature C
 
 80.0
 
 60mm 60.0
 
 FRP-Concrete A FRP-Concrete B
 
 40.0
 
 FRP-Insulation A FRP-Insulation B 20.0 0
 
 10
 
 20
 
 30
 
 40
 
 50
 
 Time in minutes
 
 50mm Sikacrete-213F: 80°C after 60 minutes 90
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 60
 
 70
 
 80
 
 LOADS AND STRENGTHS DEVELOPMENT
 
 kNm Strength development (protected member and FRP)
 
 Strength Load Strength development (unprotected member)
 
 0´ 91
 
 Design and protection of CFRP in case of fire – Only for internal use.
 
 30´
 
 60´
 
 90´
 
 120 ´
 
 180 ´
 
 240 ´
 
 NEW SIKA CARBODUR® SOFTWARE EXAMPLE: SHORT EXTERNAL PRESENTATION
 
 DESIGN GUIDELINES CURRENT STATUS Unlike the initial design models, where drastic simplifications were assumed, the current guidelines are oriented to the real calculation of complex structural members. This involves in many cases the use of difficult procedures which cannot be performed manually or by means of a simple Excel sheet.
 
 Due to this, the use of high-performance design software has become necessary.
 
 93
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKA CARBODUR® SOFTWARE: KEY ADVANTAGES PROFESSIONAL Unlike simplistic excel sheets or calculation tools, the Sika CarboDur® software comprises highperformance calculation possibilities for real situations, for example: Strengthening of full structural members according its loads distribution. The design is not based on a single section
 
 Calculation of complex geometries prestressed concrete members.
 
 Full FRP range of solutions (bonded, NSM, postensioned CFRP) according to the local availability
 
 2D and 3D interaction diagrams for columns, allowing the calculation of elements exposed to axial + bending simultaneously
 
 94
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 both for reinforced or
 
 SIKA CARBODUR® SOFTWARE: KEY ADVANTAGES SAFE All of the structural calculations strictly follow the latest International Guidelines and comprise the latest proven design procedures. No alternative or non-proven design methods are considered. Additionally, the Sika CarboDur® design software includes the necessary automatic measures, which ensure that the restrictions and logical parameters during the data entering and calculation procedure are fulfilled according to the selected FRP design guideline.
 
 If some condition is not met or exceeds any limitation, the software automatically informs the user about this fact and blocks the calculation process.
 
 95
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKA CARBODUR® SOFTWARE: KEY ADVANTAGES USER FRIENDLY The introduction of the data necessary for the calculation is written in a sequential manner. The user will not access the following stage until the necessary information is entered and all the intermediate conditions and verifications are fulfilled.
 
 It includes a significant amount of static or dynamically generated graphics, which facilitates the user the understanding of the design process and the resulting strengthening scheme.
 
 96
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKA CARBODUR® SOFTWARE: KEY ADVANTAGES USER FRIENDLY The software includes all the necessary information to facilitate its use to the engineer: >40 pages user guide.
 
 97
 
 April 2016
 
 On-screen tooltips and help icons.
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKA CARBODUR® SOFTWARE: KEY ADVANTAGES NO MORE “BLACK BOXES” The user manages and controls the whole process. Every assessment concerning the design of the FRP system can be done manually or automatically according to the user´s requirements.
 
 The user can verify the intermediate results throughout the calculation process, enabling the verification of all the design parameters by means of the information displayed on the screen.
 
 All the information concerning the design is finally shown in the calculation report, comprising the results and all the relevant data.
 
 98
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only
 
 SIKA CARBODUR® SOFTWARE: KEY ADVANTAGES AUTOMATIC UPDATES The software is automatically updated in the following cases:     
 
 Modifications or updates in the FRP design guidelines implemented in the software. Development of new FRP codes or guidelines. New design features. Development of new Sika FRP systems or modifications in the Sika FRP product range. Implementation of new languages or countries.
 
 The downloading and installation of the updates is performed automatically as soon as the user is connected to the Internet and a new version of the software is available.
 
 99
 
 April 2016
 
 New Sika CarboDur software based on TR55 and Eurocode 2 – Internal Use only