25 10 933KB
Using Aspen EDR for Rapid and Accurate Exchanger Design An Introduction
Aspen EDR Introduction
Aspen EDR (Exchanger Design & Rating) is an extension of Aspen Plus and HYSYS for performing heat exchanger sizing from within an Aspen simulation Uses standard heat exchanger sizing equations As part of the Aspen package, it uses Aspen Properties to calculate all fluid properties and heat transfer coefficients Equivalent to Pro/II-HTRI extension (which we also use)
Page 2
Aspen EDR What we use it for
Full exchanger design and specification to match design requirements, including geometry, pressure drop, vibration analysis Rate existing equipment by inputting the design geometry – test the limits of equipment offline Predict performance where operating data is missing or instrumentation lacking – fill in the blanks when evaluating a process Anticipate maintenance requirements by predicting performance with different levels of fouling
Page 3
Benefits Key advantages of using EDR inside an Aspen Simulation
Because it is integrated into a process simulation, heat exchanger design is completely linked to process design – if you change the process, you re-design the heat exchangers Avoids oversimplification of calculations – by using the rigorous thermodynamic calculations available to Aspen products Sensitivity studies Datasheet generation
Page 4
Aspen EDR How it fits into the simulation design work-flow
Process Design
Process Optimisation
Aspen EDR
Datasheet Generation
Page 5
Major optioneering desions, making sure process works Initial mass and energy balance
Refining design to obtain maximum return Simple heat exchangers, developing process specifications
Rigorous sizing of exchangers Rating against multiple design points
Full simulation report on all equipment Detailed specification sheets from EDR
Applications Aspen EDR can help design any heat exchanger
Phase Change: Condensers Evaporators Reboilers
No Phase Change Trim cooling Pre-heating Waste heat recovery
Page 6
Exchanger Types Aspen EDR can help design any heat exchanger
Shell & Tube (all TEMA types) Reboilers Kettle Thermosyphon
Air coolers Finned or bare tubes
Plate
Page 7
Example Sizing a shell & tube condenser
Page 8
Example Process Specifications
Page 9
Example Exchanger Geometry
Page 10
Example Design checking
Page 11
Final Thoughts Using Aspen EDR in design
EDR does not replace quality engineers – it enhances what they can achieve Engineers don’t need to spend their hours on time-consuming calculation and datasheets Provides a clear, visual tool for rapidly reviewing design options Instant cost estimation assists decision making Automatic check for simple design mistakes avoids common pitfalls that are easily overlooked
Page 12
Contact Us
If there’s anything we can help you with, please don’t hesitate to contact us. Flexible Process Consultants Ltd. 130 Aztec Aztec West Bristol BS32 4UB UK Website: http://flexprocess.co.uk Email: [email protected] Telephone: +44 (0) 1454 629 689 Page 13