3500 Rack Configuration and Utilities Guide 129777-01 [PDF]

  • 0 0 0
  • Gefällt Ihnen dieses papier und der download? Sie können Ihre eigene PDF-Datei in wenigen Minuten kostenlos online veröffentlichen! Anmelden
Datei wird geladen, bitte warten...
Zitiervorschau

Part Number 129777-01 Revision A, January 1996

3500 Monitoring System Rack Configuration and Utilities Guide

Return To Previous Menu

Copyright © 1995 Bently Nevada Corporation All Rights Reserved. No part of this publication may be reproduced, transmitted, stored in a retrieval system or translated into any human or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior written permission of the copyright owner, Bently Nevada Corporation Post Office Box 157 Minden, Nevada 89423 Copyright infringement is a serious matter under the United States of America and foreign copyright laws.

Contents Introduction Setting Up a New Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Installing the Software Computer Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Running the Configuration Software Ways to Use Rack Configuration Software . . . . . . . . . . . . . . . . . . . . . . 6 Configuring a New Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Building a Rack Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Modifying a Rack Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Using the Main Configuration Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Connecting a Computer to a 3500 Rack . . . . . . . . . . . . . . . . . . . . . . . . 10 Direct Connection S RS232 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Direct Connection S RS422 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Remote Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Network Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Initiating Communication with a 3500 Rack . . . . . . . . . . . . . . . . . . . . . 15 Discontinuing Communication with a 3500 Rack . . . . . . . . . . . . . . . . . 16 Uploading and Downloading Configurations . . . . . . . . . . . . . . . . . . . . 17 Opening and Saving Configuration Files . . . . . . . . . . . . . . . . . . . . . . . 19 Printing Catalog Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Copying Configuration Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Copying Monitor Channel Configurations . . . . . . . . . . . . . . . . . . . 20 Copying Channel Setpoints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Copying Module Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Configuring the Modules in a Rack Configuring the Rack Interface Module . . . . . . . . . . . . . . . . . . . . . . . . Configuring Keyphasor Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setting Monitor and Channel Options . . . . . . . . . . . . . . . . . . . . . . Setting Alarm Setpoints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring Relay Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuring Communication Gateway Modules . . . . . . . . . . . . . . . . . .

24 26 27 27 29 31 33

iii

Defining the Contents of Registers . . . . . . . . . . . . . . . . . . . . . . . . . Setting Communication Gateway Communication Parameters . . . . . Configuring a Triple Modular Redundant Rack . . . . . . . . . . . . . . . . . . . Software Operation for TMR Systems . . . . . . . . . . . . . . . . . . . . . . Configuring TMR Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

33 35 37 37 38

Using the Rack Configuration Utilities Setting Module and Channel Switches . . . . . . . . . . . . . . . . . . . . . . . . . . Setting the 3500 Rack Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . Disabling Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Enabling Trip Multiply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rack Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Viewing the System Event List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Viewing the Alarm List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Verifying the Operation of a 3500 Rack . . . . . . . . . . . . . . . . . . . . . . . .

40 41 41 42 42 42 43 44

Running the Test Utilities Starting the Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RIM Host Port Test Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setting Up Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Displaying Test Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Communication Gateway Port Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setting up Communications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Displaying Test Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

46 47 48 48 50 51 51

Files Used by Configuration Software Description by File Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 List of Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

Cable Part Numbers and Diagrams Cable Part Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Cable Pin Out Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

Modem File Programming Information

iv

v

Introduction

Introduction This manual shows how to use the following software that comes with the 3500 Monitoring system. Software Name

Function

Rack Configuration

Set operating parameters so that all the modules in a 3500 monitoring rack work together.

RIM Host Port Test

Test the output of the CONFIGURATION PORT on the Rack Interface Module (front of the rack) and the Host Connector on the Rack Interface I/O Module (rear of the rack).

Comm Gateway Port Test

Test the HOST and RACK ports on the Comm Gateway I/O module.

Setting Up a New Rack Use the following procedure to set up, configure, and verify a new rack. If your rack has a custom configuration from the factory, skip step 5. 1. Set the hardware switches and jumpers on the Rack Interface Module (RIM), the backplane, the 3500/42 Monitors, and the relay modules. The 3500 Monitoring System Rack and Installation Manual shows how to set the jumper on the backplane. The other jumper settings are described in the operation and maintenance manuals for the RIM, the 3500/42 Monitor, and the relay modules. 2. Connect the field wiring to the rack as described in the operation and maintenance manuals for all the modules installed in the rack and in the 3500 Field Wiring Diagram Package (part number 130432-01).

1

Rack Configuration and Utilities Guide

3. Test all of the communication ports on the rack by using the test utilities listed in the following table: Port to be tested...

Location of port...

Utility to use...

Refer to page...

CONFIGURATION PORT

Rack Interface Module

RIM Host Port Test Utility

47

HOST

Rack Interface I/O Module

RIM Host Port Test Utility

47

HOST and RACK

Comm Gateway I/O Module

Comm Gateway Port Test Utility

50

4. Configure the rack using the 3500 Rack Configuration Software. 5. Adjust the zero position voltage and scale factor for all monitors in the rack by using the Adjust Button on the channel options screens. 6. Use the verification procedures in the operation and maintenance manuals for the modules in the rack and the Verify option in the Rack Configuration Software to verify that the rack is configured and operating correctly.

2

Installing the Software

Installing the Software The 3500 Rack Configuration Software, the test utilities, and the configuration tutorial are shipped on a set of diskettes labeled 3500 Monitoring System Rack Configuration Software. One installation program installs all of these programs.

Computer Requirements The Configuration and test utilities require a 386/20 - 80387 computer or better, 4 megabytes of RAM, 25 megabytes of unused hard disk space, a VGA monitor, and an RS232 serial port. The computer must also have one of the following versions of Microsoft Windows installed and running: Windows 3.1, Windows for Workgroups 3.11, or Windows NT 3.5.

Installation Instructions To install the configuration, test utilities, and configuration tutorial on your computer: 1. Start Windows and choose the Run command from the File menu. 2. Insert the disk labeled "3500 Monitoring System Rack Configuration Software", (disk 1) into drive A or B. 3. In the Command Line box, type a:setup if you put the disk into drive A or b:setup if you put the disk into drive B. 4. When the installation program starts, follow the instructions on your screen. If you do a complete installation, the installation program will create a new group called 3500 Software in the Program Manager and add the following icons to the group:

3

Rack Configuration and Utilities Guide

Running the Configuration Software A 3500 rack can contain a variety of modules that can be set up to operate different ways. The process of setting system, module, and channel options so that all the modules in a 3500 rack work together is called configuration. Configuring a 3500 rack consists of using the Rack Configuration Software to set options and then downloading the settings to the rack. You can use the program two ways: You can run the program at any convenient place, save the settings in configuration files, and then later download the configuration to the rack. Or you can connect the computer to the rack first and then upload and download the configuration as required.

In this Section... topic

page

page

Ways to Use Rack Configuration Software 6

Uploading and Downloading Configurations

Using the Main Configuration Display

Opening and Saving Configuration Files 19

8

Connecting a Computer to a 3500 Rack 10 Initiating Communication with a 3500 Rack 15

4

topic

Copying Configuration Information

17

20

Running the Configuration Program

Ways to Use Rack Configuration Software The following lists illustrate the typical uses of the Rack Configuration Software.

Configuring a New Rack A 3500 Monitoring Rack cannot operate without a valid configuration. Use this process after you have installed the rack, set all switches and jumpers, and connected transducers. If your rack came with a custom configuration from the factory, you can skip this procedure. Process step... Connect the computer to the rack Initiate communication Upload the default configuration from the rack Modify the default Configuration Download the configuration to the rack Discontinue communication Disconnect the computer from the rack

Refer to page... 10 15 17 17 17

Building a Rack Configuration Use this process if you choose to prepare a series of configuration files at your desk and then download the files to the racks at a later time. Process step... Identify the modules in slots 1 through 15 Set Rack Interface Module options Set Keyphasor options Set Monitor options Set channel options for monitor modules Set Comm Gateway options Set alarm setpoints for monitor modules Set alarm drive logic for relay channels Save the configuration file

Refer to page... 8 24 26 27 27 33 29 31 19

5

Rack Configuration and Utilities Guide

Modifying a Rack Configuration Use this process to change the configuration of a 3500 rack that is installed and operating. Process step... Connect the computer to the rack Initiate communication Upload the configuration from the rack Modify the Configuration Download the configuration to the rack Discontinue communication Disconnect the computer from the rack

6

Refer to page... 10 15 17 17 17

Running the Configuration Software

Using the Main Configuration Screen The following figure lists the parts of the Main Configuration Screen and summarizes how to use them.

Menu Bar S access commands to connect to a rack, manipulate configuration files, copy configuration settings from one module to another, and control the operation of the rack.

Reference Information S helps you keep track of which rack and rack file you are configuring.

Mode Buttons and Indicator S control how the Rack Configuration Software operates.

Rack Diagram S shows the modules that are installed in the rack. Use this diagram and the Options and Setpoints mode buttons to move to configuration screens.

7

Rack Configuration and Utilities Guide

Although you can enter most configuration settings in any order you choose, we recommend that you create a rack configuration by using the mode buttons on the Main Configuration display from top to bottom as suggested in the following figure. Because these buttons control how the Configuration Software operates, be sure that the correct button is depressed before you proceed with an operation.

Build a rack. Place modules in slots 1 through 15 by clicking on a slot and then selecting a module from the drop down list.

Set module and channel options. Enter the Module Option screen by clicking the Options button and then clicking on the module to be configured.

Set alarm setpoints for channels in monitor modules Enter the Alarm Setpoint screen by clicking on the Setpoints push button and then clicking on the monitor module to be configured.

8

Running the Configuration Software

Connecting a Computer to a 3500 Rack You can connect a computer to a 3500 Monitoring rack the following three ways: Method for Connecting

Use this method...

Direct

to temporarily connect your computer when the computer is near the 3500 rack. Direct connection can use RS232 or RS422 protocol.

Remote

to connect a 3500 rack to a computer that is located off site. The computer must have a modem and the 3500 rack must have access to a dedicated phone line.

Network

if your computer is connected to a network that has a station that is connected to the HOST connector on the Rack Interface I/O module of a 3500 rack and is running the Data Acquisition DDE Server Software.

9

Rack Configuration and Utilities Guide

Direct Connection S RS232 Connect the computer directly to the rack by using an RS232 cable (Bently Nevada part number 130118-XXXX-XX) as shown in the following figure. If the Rack Interface I/O Module does not have an internal modem, you can also connect the RS232 cable to the Rack Interface I/O Module by using the port labeled HOST. Set the switch below the port to the RS232 position. Using the CONFIGURATION PORT lets you configure only the rack that your computer is connected to. Using the HOST port on the Rack Interface I/O Module lets you use the rack address to configure all of the racks connected in the daisy chain.

Direct Connection to the Rack Interface Module

10

Running the Configuration Software

Direct Connection S RS422 If the Rack Interface I/O Module does not have an internal modem, you can connect the computer directly to the rack using RS422 communication. Install an RS232-to-RS422 converter between the computer and the rack. The cable from the converter should be connected to the port on the rear of the Rack Interface I/O Module labeled HOST. Set the switch below the port to the RS422 position.

Direct Connection Using RS422 Protocol An alternate method of direct connection to RS422 is to install an RS422/485 Data Aquisition Card (Bently Nevada part number 02230415) in your PC, and using the Host to 3500 Rack RS422 Interface Cable (Bently Nevada part number 132632-XXXX-XX for PVC insulation or 132633-XXXX-XX for Teflon insulation). Connect the cable from the RS422 Card to the port on the rear of the Rack Interface I/O Module labeled HOST. Set the switch below the port to the RS422 position.

11

Rack Configuration and Utilities Guide

Remote Communication The 3500 Monitoring Rack has two versions of the Rack Interface I/O Module: one with a RS232/422 terminal and one with an internal modem. The internal modem will operate at speeds up to 14.4 kbaud. With Internal Modem

With RS232/422 connector.

Connecting the Computer to a Rack using a Modem

Many laptop computers and some desktop models also contain internal modems. Baud rates on these modems can vary from 4800 to 28.8 kbaud. The modem-tomodem communication speed is determined by the quality of the phone connection and the protocol of the information being transmitted. The speed at which the computer communicates with the modem does not have to be identical to the modem-to-modem communication rate. To use modems to connect the computer and the rack: 1. Verify that you have dedicated telephone communications available at the computer and rack locations.

12

Running the Configuration Program

2. At the computer: Connect the phone line to the internal or external modem phone port. If you use an external modem, connect a standard modem cable between the computer serial COM port and the modem. 3. At the rack: Connect the phone line to the internal modem on the Rack Interface I/O Module. If you use an external modem, connect the standard modem cable to the port labeled CONFIGURATION PORT on the front of the RIM or to the port labeled HOST on the Rack Interface I/O Module. Verify that the RS232/RS422 switch on the I/O module is set to the RS232 position. The following figures show some of the ways for using modems to connect the computer to the rack.

Standard modem cable

3500 Rack with Internal Modem

Standard modem cable

3500 Rack with External Modem

Note:

The Rack Interface Module (RIM) configuration must be set to indicate a modem is present on the front or rear 3500 RIM port.

13

Rack Configuration and Utilities Guide

Network Connection If the configuring computer has network access to a Data Acquisition DDE Server as shown in the following figure, you can configure all racks that are daisy chained to the server by using the Network connection. Dynamic Data Exchange (DDE) is a method of exchanging or providing data to and from Windows applications. This method lets multiple devices access the data simultaneously.

Data Acquisition DDE server

Configuring Computer

Daisy-chained 3500 racks

Ethernet cable

Initiating Communication with a 3500 Rack After you have connected the computer to the rack and started the Rack Configuration Software, use the following procedure to initiate communication between the rack and the computer: 1. Select the Connect option in the File menu. A list of connection methods will appear (Direct, Remote, and Network). 2. Select the connection method that corresponds to how your computer is connected to the rack(s) that you will configure. Refer to the previous section for information about these methods. 3. Enter the appropriate communication parameters into the connect dialog box using the following table for reference:

14

Running the Configuration Software

Communication Parameter

Description

Connect Password

The password on the 3500 rack to be configured. This password is set when the RIM options are configured.

Rack Address

The setting on the RACK ADDRESS switch on the Rack Interface Module in the 3500 rack to be configured.

Com Port

The connector on the configuring computer used to communicate with the 3500 rack.

Baud

The rate of the computer-to-modem or Computer-torack communication.

Phone Number

The phone number of the modem for the 3500 rack to be configured

Data Acquisition (DDE) The network name of the computer that is running Server Computer Name 3500 Data Acquisition software and that is connected to the daisy-chained 3500 racks to be configured. 4. Initiate communication by clicking on Connect. A successful connect to the rack is indicated by the message "Connection established".

Discontinuing Communication with a 3500 Rack Before you disconnect the cable between the configuring computer and the rack, discontinue communication by clicking on the Disconnect command in the File menu. This command initiates the following actions: C return any module that is still in configuration mode to run mode (under user control) C release the configuration token if the configuring computer has the token C hang up the modem if the computer was using remote communication

15

Rack Configuration and Utilities Guide

Although disconnecting the cables without invoking the Disconnect command causes no harm, we recommend using the command when you're finished communicating with a rack.

Uploading and Downloading Configurations You transfer configuration settings between the configuring computer and the rack to be configured by using a process called uploading (rack to computer) or downloading (computer to rack). The Upload and Download commands are in the File menu. To upload a configuration: 1. Connect the configuring computer to the rack to be configured. (Refer to page 10 of this manual.) 2. Establish communication with the rack by using the procedure in the "Initiating Communication with a 3500 Rack" section. 3. Click on the Upload command in the File menu. A prompt will appear that indicates the progress of the upload and indicates if the upload was successful. 4. Terminate communication with the rack by clicking on the Disconnect command in the File menu. 5. Disconnect the configuring computer from the rack. If an error occurs while uploading a configuration from the rack, the upload will continue and the default configuration will be loaded for the module where the error occurred.

To download a configuration: 1. Connect the configuring computer to the rack to be configured. (Refer to page 10 of this manual.) 2. Establish communication with the rack by using the procedure in the "Initiating Communication with a 3500 Rack" section. 3. Move the configuration keylock on the front panel of the Rack Interface Module from Run to Program. (All functions of the rack will continue operating with the keylock set to Program.)

16

Running the Configuration Software

4. Click on the Download command in the File menu. The Download Configuration screen will appear. 5. Choose which module configurations to download by marking the check box next to the module name. 6. Initiate the download by clicking OK. 7. Set the keylock on the front panel of the Rack Interface Module from Program to Run. 8. Terminate communication with the rack by clicking on the Disconnect command in the File menu. 9. Disconnect the configuring computer from the rack. If an error occurs while downloading a configuration to the rack, the downloading will stop and you can choose whether to download the portion of the configuration that is correct or to abort the download.

17

Rack Configuration and Utilities Guide

Opening and Saving Configuration Files Use the Open command in the File menu to load a configuration file that has been stored on disk into the Rack Configuration Software. Use the Save command to store the current configuration in the Rack Configuration Software to a file on disk. We recommend that you save the configuration of all 3500 Monitoring Racks to files on disk. All rack configuration files contain a maximum of 8 characters and end with a file name extension of .RAK. The default directory for configuration files is \3500\trains\primcfg. Although you can place the files in any directory, keep the following special considerations in mind: C If multiple 3500 racks are daisy chained together, place the rack configuration files for these racks in the same directory. C If the 3500 Data Acquisition Software is to provide historical trend data, place all rack configuration files for the racks daisy chained to the Data Acquisition computer in the \3500\trains\primcfg directory.

Printing Catalog Numbers The Print menu lets you print a list of the catalog numbers of all the modules that are displayed on the Main Configuration screen. This option makes it easy to order a new 3500 rack or to order replacement modules for an existing rack.

18

Running the Configuration Software

Copying Configuration Information The 3500 Rack Configuration Software makes it easy to copy the configuration settings of channels and modules.

Copying Monitor Channel Configurations The arrow buttons let you copy channel settings between channels in a channel pair...

... or from one channel pair to another.

An equal sign between the arrow buttons indicates that the configuration of the channels or channel pairs are the same. "Copy" indicates that the configuration of the channels or channel pairs are not the same. The arrow buttons copy the monitor options but not the alarm setpoints.

19

Rack Configuration and Utilities Guide

Copying Channel Setpoints The Copy button on the Setpoint Configuration screens lets you copy the alarm setpoints from one channel in a monitor to another channel of the same type.

Copying Module Configurations The Copy menu lets you copy the configuration parameters from one module to another module of the same type. This command copies both the module options and the alarm setpoints.

20

Running the Configuration Software

Use the upper row of buttons to choose the slot of the module with the configuration that you want to copy.

Use the lower row of buttons to choose the slot or slots that you will copy the configuration to.

If the slot or slots chosen in the lower row of buttons do not contain the same type of module as in the slot chosen in the upper row, the program will replace the module before it copies the configuration parameters.

21

Rack Configuration and Utilities Guide

Configuring the Modules in a Rack Configure a 3500 rack by setting the operating parameters for all modules in the rack and for all channels in each module. You set these parameters by using dialog boxes that appear when you click on the Options button and then on a module. The dialog boxes use conventional Windows selection tools like check boxes, radial buttons, and drop down lists. If you are not familiar with these tools, refer to your Windows documentation. The online help system for the Rack Configuration Software contains definitions of all the configuration options.

In this section... topic

page

Configuring the Rack Interface Module 24

22

Configuring Keyphasor Modules

26

Configuring Monitors

27

topic

page

Configuring Relay Modules

31

Configuring Comm Gateway Modules

33

Configuring a Triple Modular Redundant Rack

37

Configuring the Modules in a Rack

Configuring the Rack Interface Module The option display for the Rack Interface Module (RIM) lets you set options for the power supply and the RIM. The screen looks like this:

The following table defines the configuration parameters for the RIM: Configuration Parameter

Description

Rear Port / Front The Rack Configuration Module has two ports for accessing Port the information in the 3500 rack. These ports can operate simultaneously and can transmit and receive messages using a Bently Nevada proprietary protocol. Use these fields to identify how devices are connected to these ports. I/O Option

Identifies the type of Rack Interface I/O Module that is installed in the rack: RS232/RS422 I/O Module or Internal Modem I/O Module.

External Modem When the rack is equipped with an RS232/RS422 module, this field lets you identify the type of external modem connected to 3500 rack.

23

Rack Configuration and Utilities Guide

Configuration Parameter

Description

Byte Timeout

The number of bytes of communication line "dead time" needed to signal an end of message. Each port on the Rack Interface Module may have a different Byte Timeout setting.

Connect Password

A password that "gates" all access to the 3500 rack. Without this password, the Rack Interface Module will not accept commands or requests from an external personal computer.

Configuration Password

A password that "gates" configuration information to be downloaded to a 3500 rack. Without this password, the Rack Interface Module will not accept any configuration commands from an external personal computer.

Dynamic Signal The monitors that will provide data to the External Dynamic Option Data Interface (DDIX) or the External Transient Data Interface (TDIX). The DDIX and TDIX are Bently Nevada communication processors. Agency Approval The agency approval for the 3500 rack. The option selected in this field must match the approval rating of the rack. Mounting Option The mounting configuration of the rack being configured. The option selected in this field must match the mounting option of the rack. Power Supply Top / Bottom

24

The power supplies that are installed in the rack.

Configuring the Modules in a Rack

Configuring Keyphasor Modules Configure Keyphasor modules by completing the configuration parameters on the Keyphasor screen.

The following table defines the configuration parameters for the Keyphasor Module: Configuration Parameter

Description

Signal Polarity

The type of mark observed by the Keyphasor transducer S notch or projection.

Type

The type of Keyphasor transducer connected to the Keyphasor I/O Module

Hysteresis

The voltage level above and below the threshold value which is required to trigger the conditioned Keyphasor signal.

Threshold

The voltage level of the input signal from the Keyphasor transducer where the conditioned Keyphasor signal is triggered.

25

Rack Configuration and Utilities Guide

Configuration Parameter

Description

Events Per Revolution

The number of pulses in a Keyphasor signal for each shaft rotation.

Orientation

The location of the Keyphasor transducer on the machine.

Upper RPM Limit

The upper limit of the full scale range for the Keyphasor rpm. The Keyphasor Module will scale the rpm value between 0 and this value.

RPM Clamp Value

The value that the data provided through the Communication Gateway will be clamped to when a Keyphasor transducer goes invalid.

I/O Module

The type of I/O module connected to the Keyphasor Module.

Configuring Monitors The two steps for configuring monitors are setting monitor and channel options and setting alarm setpoints.

Setting Monitor and Channel Options Monitors have two dialog boxes for setting options. The first box is for setting monitor options and looks similar to the following screen.

26

Configuring the Modules in a Rack

The second box is for setting options for each channel in the monitor module and looks like this:

27

Rack Configuration and Utilities Guide

Setting Alarm Setpoints An alarm setpoint is the level of the proportional value at which an alarm will occur if the value moves above or below the level. To set alarm setpoints, use the monitor option displays to enable alarms and use this approach:

Choose up to two proportional values that will have setpoints for danger alarms. Adjust all alarm setpoints except phase by either clicking and dragging the bargraph... ...or by entering the setpoint value in the number boxes. The alarm will occur if the value moves outside of the colored area in the bar graph.

28

Configuring the Modules in a Rack

Adjust the phase angle for 1X or 2X acceptance regions by entering the angles into the number boxes above or below the angle diagrams. The acceptance region is indicated by the yellow or red area in the circle.

If the red or yellow area is outside of the intended acceptance region, reverse the angle values in the number boxes.

29

Rack Configuration and Utilities Guide

Configuring Relay Modules Use the Relay Association screen to enter the alarm logic that controls what alarms cause the relays to activate. Enter the Relay Association screen by clicking on the Options pushbutton and then clicking on the relay module to be configured. To enter the alarm logic: Click on a module...

...the list of alarms for the module will be displayed here. The number of alarms depends on what channels are active and which alarms are configured.

Choose the relay channel to configure in this group box. The alarm logic in the Relay Association window contains the logic that controls when a relay channel is activated. The logic consists of alarm codes, AND (*) and OR (+) symbols, and parentheses. The AND operator has precedence over the OR operator and parentheses are used to control the order of the operators for complex logic. When the logic is true, the relay for that channel will activate.

This figure shows S02C03A2 S02C##A2 the meaning of the Alarm level (2) / Danger Code applies to digits in alarm Channel number (3) all channels in codes: Slot number (2)

30

in the monitor slot

Configuring the Modules in a Rack

To enter alarm logic for the channel: Add an alarm code by clicking on the code and then clicking Enter or by double clicking on the code. The alarm code will appear in the Alarm Drive Logic box.

Add AND, OR, and parentheses to the alarm logic by clicking on these buttons. Use the left arrow button to backspace one character in the string. Use the CLR button to clear the alarm logic box and start over.

31

Rack Configuration and Utilities Guide

Configuring Communication Gateway Modules The Communication Gateway screen lets you enable a Distributed Control System (DCS) computer to scan 3500 racks more efficiently and set the communication parameters of the HOST and RACK ports on the Comm Gateway I/O Module.

Defining the Contents of Registers Registers 30001 to 30448 Modbus (0 to 447 decimal) in the Communication Gateway Module are reserved for the primary proportional values from monitors and Keyphasor Modules. The Communication Gateway screen lets you place these primary proportional values into contiguous registers so that a DCS can scan 3500 racks efficiently. You can reduce the scan time by including only those values required by the DCS and excluding the contents of unnecessary or empty registers. All the other data that is available from the monitors and Keyphasor Modules is stored in fixed registers on the Communication Gateway Module. All fixed and programmable registers of the Communication Gateway Modules are described in the Communication Gateway Operation and Maintenance Manual (part number 129769-01). To define the contents of the reserved registers, enter integers from 0 to 32 into the number boxes in the columns labeled "Positions Reserved". The integer indicates the number of channels in the modules whose primary proportional value will be included in the message. Enter the number of channels whose primary values will be included in the message

The number in parenthesis indicates number of channels in the module that have proportional values. Enter 0 to include no values from the module. Enter 4 to include the primary proportional value from all 4 channels in a module. Enter a number that is

32

Configuring the Modules in a Rack

greater than the number shown in parenthesis to insert zeros into the successive registers of the message. Press Use Module Defaults to include the primary proportional value from all channels in all modules in the rack that have proportional values available.

For example, the above display would include the following values in the Communication Gateway registers: Register Address

The register contains the primary proportional value from...

Decimal

Modbus

Slot #

Channel #

0 1 2 3 4 5 6 7 8 to 447

30001 30002 30003 30004 30005 30006 30007 30008 30009 to 30448

2 5 5 5 5 none none 9 none

1 1 2 3 4 zero zero 1 439 zeros

33

Rack Configuration and Utilities Guide

To determine which values are the primary proportional value for each module, refer to the operation and maintenance manual for that module.

Setting Communication Gateway Communication Parameters The Port 1 and Port 2 buttons on the Communications Gateway screen let you set communication parameters for the HOST and RACK connectors on the Communication Gateway I/O Module. When you click on Port 1 or Port 2, the following window will appear.

The following table describes the fields in this window: Communication Parameter

34

Description

Active

Turn a port on (: ) or off (9 ). When a port is turned off, no machinery data is available.

Address

The address of the modbus port on the Communication Gateway I/O Module.

Connection

The type of connection between the 3500 rack and the Distributed Control System (DCS) computer.

Configuring the Modules in a Rack

Communication Parameter

Description

Config Allowed Specify if the 3500 rack can be configured from the DCS computer. Check (:)the box for yes; clear (9) the box for no. Refer to the Communication Gateway Operation and Maintenance Manual for a list of items which can be configured through the Communication Gateway ports. Parity

The type of communication verification contained in each message byte. The parity setting in a Communication Gateway Module must agree with the setting at the external device connected to the module. Each Communication Gateway port may be set up with a different parity setting.

Stop Bits

The number of bits which will be added to each 3500 Communication Gateway message. Each byte within a message will contain 1 start bit, 8 data bits, and either 1 or 2 stop bits. The Stop Bits setting in the Communication Gateway Module must agree with the setting at the external device connected to the module. Each Communication Gateway port can have a different Stop Bits setting.

Baud Rate

The rate at which messages are transmitted and received from the 3500 Communication Gateway. Specifically, it represents the number of bits which can be transmitted and received from the Communication Gateway in 1 second. The Baud Rate setting in the Communication Gateway Module must agree with the setting at the external device connected to the module. Each Communication Gateway port can have a different Baud Rate setting.

Byte Timeout

The amount of time that the Communication Gateway module will wait to determine that a command has been received on the DCS link. This value is expressed as the time required to send x bytes at the current baud rate.

Full Scale Data The value used to scale the proportional data. Range

35

Rack Configuration and Utilities Guide

Communication Parameter

Description

Numeric Format The number system that the communication protocol uses to send and receive data. For the Modbus protocol, the system is Hex.

36

Configuring the Modules in a Rack

Configuring a Triple Modular Redundant Rack A triple modular redundant (TMR) rack contains a TMR Rack Interface Module and redundant power supplies, monitors, and TMR relay modules. To identify the rack as TMR: 1. Click on the Slot button. 2. Click on the Rack Interface Module. A drop down list will appear. 3. Choose "TMR" from the list.

Software Operation for TMR Systems The Configuration Software operates differently to help you configure TMR racks more easily. Take note of the following items when you configure a TMR rack: C Since the program automatically inserts groups of three monitors into a TMR rack, be sure that the two slots to the right of the monitor to be inserted are empty. C For groups of TMR monitors that use the TMR I/O (Bussed) option: set the monitor options, channel options, and alarm setpoints for all monitors in the group by configuring the left-most monitor only. The Rack Configuration Software automatically copies these configuration settings to the other monitors in the group. C Enter alarm drive logic for just one of the two TMR Relay Modules. The Rack Configuration Software automatically copies the alarm drive logic from one TMR Relay Module to the other. You can enter or edit the alarm drive logic in either the upper or lower relay. C The alarm logic for channels in relay modules uses alarm codes from the left-most monitor in a TMR group. Although the alarm code includes the slot number for the left-most monitor in the group, the alarm logic applies to all the monitors in the group.

37

Rack Configuration and Utilities Guide

Configuring TMR Functions TMR racks have the following additional functions that must be configured: I/O module and Voting. TMR I/O Options Monitors in a TMR group can have input from redundant transducers (TMR I/O: Discrete) or from a single transducer (TMR I/O: Bussed). The following figures show the channel 1 input for the TMR I/O options: Discrete and Bussed.

TMR I/O: Discrete

TMR I/O: Bussed

Voting Options The TMR Rack Interface Module continuously checks the output of monitors in a rack by using 2 out of 3 voting. The configuration settings used to control this voting are Comparison and % Comparison. Comparison: The enabled proportional value used in the 2 out of 3 voting.

38

Configuring the Modules in a Rack

% Comparison: The highest allowed percent difference between the middle value of the three monitors in a TMR group and the individual values of each monitor.

39

Rack Configuration and Utilities Guide

Using the Rack Configuration Utilities This section describes the options in the Utilities menu. You must be connected to a 3500 rack to use these options.

Setting Module and Channel Switches Module and channel switches let you temporarily bypass or inhibit module and channel functions. A checked box (:) indicates that the switch is enabled. A cleared box (9) indicates that the switch is disabled. The functions of these switches are defined in the individual module manuals and in the help system of the Rack Configuration Software.

40

Using the Rack Configuration Utilities

Setting the 3500 Rack Date and Time Use this dialog box to read or reset the date and time on the clock in a 3500 Monitoring rack. The date and time are used to time stamp data collected from monitor channels and items entered into the Alarm and System Event lists.

Clicking on the Send button will set the rack date and time as follows: If the Send Host Data and Time to Rack box is...

...the Send Time command will ..

selected

send the current data and time of the computer to the rack

not selected

send the date and time that is shown in the Date and Time box to the rack

Clicking on the Read button will cause the configuration software to read and display the date and time from the 3500 rack. When this dialog box is initially displayed, it will contain the computer's date and time.

Disabling Alarms Alarm Inhibit lets you disable alarms (both alert and danger) and relay activation in the rack. This feature is useful when you service and verify your 3500 rack. The current status of Rack Alarm Inhibit

41

Rack Configuration and Utilities Guide

(hardware contact and software) are displayed at the top of this screen.

Enabling Trip Multiply Trip Multiply lets you extend monitor alarm setpoints by the trip multiply value specified in the monitor option. This feature is useful during machine ramp-up or ramp-down. The current status of Trip Multiply (hardware contact and software) are displayed at the top of this screen.

Rack Reset Rack Reset lets you reset latched alarms, latched not OK's and timed OK defeat. This feature is useful when you service and verify your 3500 rack.

Viewing the System Event List System events are actions or occurrences such as configuration changes, module errors, and status messages. The System Event List is filled in a round robin fashion and may contain up to 500 entries. The help system in the Rack Configuration Software defines all the system events.

42

Using the Rack Configuration Utilities

You can run a self-test on any module in a 3500 rack by using the Module Selftest button on the System Events screen. The results of the self-test are posted in the list. The help system in the Rack Configuration Software explains how to run a self-test. The configuration software uploads 20 events at a time from the 3500 rack. You can scroll through these 20 events by dragging the vertical scroll bar up and down or by clicking the up and down arrows. Display additional 20-event pages by pressing the Page Up, Page Down, or Latest Events buttons.

Viewing the Alarm List The Alarm List is a chronological list of alarms, not OK events, and tripped relays. The list is filled in a round robin fashion and contains up to 1000 entries.

The configuration software uploads 20 events at a time from the 3500 rack. You can scroll through these 20 events by dragging the vertical scroll bar up

43

Rack Configuration and Utilities Guide

and down or by clicking the up and down arrows. Display additional 20-event pages by pressing the Page Up, Page Down, or Latest Events buttons.

Verifying the Operation of a 3500 Rack The Verification screens display information about the status and output of the modules in a 3500 rack. Use the output of these screens and the procedures in the operation and maintenance manuals that come with the 3500 modules to verify the operation of a 3500 rack.

44

Running the Test Utilities

Running the Test Utilities The two test utilities that come with the Rack Configuration Software are the RIM Host Port Test Utility and the Comm Gateway Port Test Utility. This section shows how to run the utilities and explains how each utility displays data.

Starting the Utilities If you installed the 3500 Rack Configuration Software and test utilities by using a normal installation, icons for the configuration software and test utilities will be placed in a group called 3500 Software.

Start a test utility by double clicking on the icon for that utility. The opening displays of the utilities show how to connect the computer running the utility to a 3500 rack.

45

Rack Configuration and Utilities Guide

RIM Host Port Test Utility The Host ports on the Rack Interface Module and the Rack Interface I/O Module are used for communication between a computer that runs the Rack Configuration Software or the Data Acquisition/DDE Server Software and a 3500 rack. The ports are also used to daisy chain up to twelve 3500 racks. The RIM Host Port Test Utility lets you verify that the HOST ports are operating properly. The options in the menu bar operate as described in the following table: Option Name

Description

File Start Display Program Open the screen that displays the output of the communication port being tested. Exit Com Set Up Help Program Information

End the utility. Set options that control the communication between the test computer and the rack. Display a screen that explains what the utility does.

About Display a screen that contains copyright information and the version number of the utility.

46

Running the Test Utilities

Setting Up Communications The Program Set Up display of the RIM Host Port Test Utility contains the following options: Option Name

Use this option to...

Run Mode

Identify the type of connection between the computer and the rack. Direct: RS232 cable. Modem: modem and telephone line.

Com Port

Identify the computer port that is connected to the rack.

Baud Rate

Choose the rate of communication between the computer and the rack.

Modem

Identify the type of modem connected to the test computer and the telephone number of the rack to be tested. Use this field only if you are using a modem to connect the test computer to the rack.

Displaying Test Data To display the output of the RIM Host Port, click on Start Display Program in the File menu. The RIM Host Port Test Utility will continue to scan the selected 3500 racks until you click on Stop Scan. The utility displays the information as shown in this display.

47

Rack Configuration and Utilities Guide

The following table describes the fields in the Test Data Display: Field Name

Description

Address

The address of the rack being tested.

Family #

The name of the device being tested.

RIM #

The model number of the Rack Interface Module in the rack being tested.

Firmware

The version number of the firmware that is running in the Rack Interface Module being tested.

Rack Status Bytes

An 8-bit word that contains information about the operating condition of the communication port being tested.

When you click on a byte number button, the utility displays additional information about the meaning of the bits:

48

Running the Test Utilities

Communication Gateway Port Test The HOST and RACK ports on the Communications Gateway I/O Module let you connect 3500 Monitor Racks to a process control system that uses Modbus communication protocol. The Comm Gateway Port Test Utility lets you verify that these ports are operating properly. The options in the menu bar operate as described in the following table: Option Name

Description

File Scan Program

Display the communication parameters of any Comm Gateway Module in a Modbus daisy chain.

Data Display

Display all proportional values for a monitor.

Manual Program

Send messages to the Comm Gateway and display the response in hex values.

Exit

End the utility.

Com Set Up Help Program Information

About

Set options that control the communication between the test computer and the rack. Display a screen that explains what the utility does.

Display a screen that contains copyright information and the version number of the utility.

49

Rack Configuration and Utilities Guide

Setting up Communications The Com Set Up display of the Comm Gateway Port Test Utility contains the following options: Option Name

Use this option to...

CGM Port Address

Identify the port address of the Communication Gateway Module.

Comm Port

Identify the computer port used to communicate between the test computer and Comm Gateway Module.

Baud Rate

Choose the rate of communication between the computer and the Comm Gateway Module.

Parity

Choose the type of communication verification contained in each message byte. The parity setting within the Communication Gateway Module must agree with the setting at the external device connected to the module. Each Communication Gateway port can have a different parity setting.

Stop Bits

Set the number of bits which will be added to each 3500 Communication Gateway message. Each byte within a message will contain 1 start bit, 8 data bits, and either 1 or 2 stop bits. The Stop Bits setting must agree with the setting at the external device connected to the Communication Gateway. Each Communication Gateway port may be set up with a different Stop Bits setting.

If you don't know the communication settings for a Comm Gateway Module, you can have the Scan Program under the File menu automatically detect these settings.

Displaying Test Results The Comm Gateway Port Test Utility lets you display test results three ways: Scan Program, Data Display, and Manual Program.

50

Running the Test Utilities

Scan Program lets you display the communication parameters of any Comm Gateway Module in the Modbus daisy chain. Enter the address of the rack at the prompt.

Data Display lets you display all proportional values for a monitor as a percent of full scale.

The proportional value as a percent of full scale.

The number label for the proportional value.

Use the tables in the Appendix A of the Communication Gateway Module Operation and Maintenance manual (part number 129769-01) and the operation and maintenance manuals of the 3500 monitors to determine what proportional value corresponds to the numbers on the Data Display. Manual Program is for advanced communication diagnostics. This test lets you compose messages to send to the Comm Gateway Module and then displays the response to the message in decimal values.

51

Rack Configuration and Utilities Guide

Use this portion of the display to compose the message to send to the Comm Gateway Module.

The response to the message appears here in decimal value.

Appendix A of the Communication Gateway Operation and Maintenance manual (part number 129769-01) describes the structure of the messages that are composed and received on the Manual Program display.

52

Files Used by Configuration Software

Files Used by Configuration Software The installation program adds files to your hard disk that are used by the Rack Configuration Software. Do not modify or move any of the files listed in this section except for the rack configuration files (.RAK).

Description by File Extension Extension

File Type

Use

.DEF

Default

Default configuration settings.

.DAT

Modem data files

Modem and modem initialization strings.

.TBL

DSP Table files

Tables of DSP coefficients that the software uses to configure corner frequencies.

.DLL

Windows Dynamic Link Libraries

Assist the Rack Configuration Software in a number of ways.

.INI

Initialization

Stores startup information such as customer name, customer location, and ship date.

.VBX

Microsoft Visual Basic application development files

The Rack Configuration Software uses these files to create the user interface.

.RAK

Rack Configuration Files

Store user-defined rack configurations.

.EXE

Executable software and utilities

The main configuration program and product service utilities.

.HLP

Help files

The 3500 Rack Configuration help file.

53

Rack Configuration and Utilities Guide

List of Files The 3500 installation program adds the following files to your hard drive:

** This file comes with MS Windows. The installation program adds this file only if it is not found or if the version on the hard disk is older than the one on the installation disks.

54

Files Used by Configuration Software

The following diagram is a continuation of the diagram from the previous page and shows the additional subdirectories and files that are under dsptbls.

55

Rack Configuration and Utilities Guide

Cable Part Numbers and Diagrams This section contains information about the cables used to connect the configuring computer to 3500 Monitoring racks.

Cable Part Numbers Cable Part Number

Description

130118-XXXX-XX

Host to 3500 Rack RS232 Interface Cable

132632-XXXX-XX

Host to 3500 Rack RS422 Interface Cable (PVC Insulation)

132633-XXXX-XX

Host to 3500 Rack RS422 Interface Cable (Teflon Insulation)

02290860

Host to External Modem Cable -- RS232

130119-01

Host Computer to RS232/422 Converter Cable

130120-XXXX-XX

RS232/422 Converter to 3500 Rack Cable -RS422 (PVC Insulation)

131106-XXXX-XX

RS232/422 Converter to 3500 Rack Cable -RS422 (Teflon Insulation)

130121-XX-XX

RS422 Extension Cable

Cable Pin Out Diagrams The following diagrams show the wiring for cables that are manufactured by Bently Nevada:

56

Cable Part Numbers and Diagrams

Part Number 130118-XXXX-XX Host to 3500 Rack RS232 Interface Cable

Part Number 132632-XXXX-XX / 132633-XXXX-XX Host to 3500 Rack RS422 Interface Cable

57

Rack Configuration and Utilities Guide

Part Number 02290860 Host to External Modem Cable -- RS232

Part Number 130119-01 Host Computer to RS232/422 Convert Cable

58

Cable Part Numbers and Diagrams

Part Number 130120-XXXX-XX / 131106-XXXX-XX RS232/422 Converter to 3500 Rack Cable -- RS422

Part Number 130121-XX-XX RS422 Extension Cable

59

Rack Configuration and Utilities Guide

Modem File Programming Information The Rack Configuration Software supports a number of popular modems. To customize your configuration software to work with these and other modems a modem setup file has been provided in the \3500 directory called HOSTMDM.DAT. The modem setup file contains programming information for all supported modems and allows one additional custom configuration. This file is a simple ASCII text file that can be inspected or modified with any DOS or Windows text editor. The following entries are provided in the modem setup file: Setup Entry

Use...

Hayes Ultra 9600

For Hayes Ultra 9600 modem using the V.32 protocol.

Hayes Optima 9600

For Hayes Optima 9600 modem using the V.32 protocol.

Motorola FasTalkII

For Motorola FasTalkII modem using the V.32 protocol

Custom

For support of other types of modems. The entry supplied is a copy of the Hayes Ultra 9600 modem setup.

To support other modems, use the Custom modem type. To do this, you should edit the Custom entry as required and select the Custom modem type from the Remote Connect screen. Be aware that modems are highly nonstandard; getting a new modem to work will require an intimate understanding of how to operate and program that modem. The modem setup file consists of a "entry" name followed by 6 modem command fields. The fields contains modem setup and control information along with modem initialization strings. Use these guidelines when editing the fields: C The maximum length of a line is 80 ASCII characters. Consult your modem manual to determine the maximum initialization string length. C The commands must be in the same order as listed in the following table.

60

Modem File Programming Information

C Fields that are not needed should be left blank but not deleted. C Lines cannot be added or swapped.

Custom Modem Line Definitions Modem File Entry 1 2 3 4 5

Line Definition

Reset to factory default string Initialization string 1 Initialization string 2 * Dial Method (Touch Tone or Pulse) Connect string (the text returned when a connection is made) Seconds to wait for answer *

6 * Null if not needed Some experimenting may be required to obtain the modem settings that give the best results. Since the modem to modem connection baud rate is determined by the modem, it is usually necessary to enable hardware flow control (RTS/CTS). Many modems will automatically default to data compression. This feature can cause large "dead times" in commands and responses from the Personal Computer and the 3500 rack. The 3500 rack looks for a specific amount of dead time in a command to signify the end of a message. To ensure that the rack correctly services commands sent from the personal computer, you should either set the "Byte Time Out" field in the Rack Interface Module's configuration to a large value OR setup the modem to not utilize these features.

61

Rack Configuration and Utilities Guide

62

Modem File Programming Information

63