46 0 1MB
Tetra Pak® A3/Speed 0300
iLine
™
Technical Data Tetra Pak A3/Speed 0300
CAPACITY FILLING MACHINE Packages per hour (selectable capacity): TBA 125 S: 16.000-20.000-24.000 p/h TBA 200 B: 16.000-20.000-24.000 p/h TBA 200 M: 16.000-20.000-24.000 p/h TBA 200 S: 16.000-20.000-24.000 p/h TBA 250 B: 16.000-20.000-24.000 p/h TBA 250 S: 16.000-20.000-24.000 p/h TBA 1000 Sq PLH: 9.000-12.000-15.000 p/h TBA 1000 S PT: 9.000-12.000-15.000 p/h TBA 1000 B: 9.000-12.000-15.000 p/h TBA 1000 Sq PT: 9.000-12.000-15.000 p/h Note: No viscous and semi-viscous product can be packed
PRODUCT SUPPLY Product pipe size (portion packs) Product pipe size (family packs) Product temperature range C° (F°)
2”- 3” 3” 10-30 (50-86)
Note 1: higher product temperatures are possible with reduced capacity Note 2: processing capacity +20%
Characteristic
Value
Notes
Supply pressure accepted range
150 - 250 kPa (1.5 - 2.5 bar) [21.7 - 36.2 psi]
Measured near the product valve.
Max. pressure variation
±50 kPa (±0.5 bar) [±7.25 psi]
Variation within the supply pressure accepted range.
Max. pressure shock
100 kPa (1 bar) [14.5 psi]
The pressure shock duration is a maximum of 1 second (within the pressure range).
Filling temperature
10 - 30°C (50 to 86°F)
Maximum fluctuation during production ±5°C.
20%
Feed capacity at the first start and for bucket refilling, see note below.
Overcapacity
Particles
Absent
Product must leave no hard residue on a 600 μm mesh.
Citrus fibres
130 (>266) 2,4 during production + 7,0 for ICU Cycle
35% 3,0 to 5,0
FP 240 cc/1.000.000 packs PP 160 cc/1.200.000 packs
Technical Data Tetra Pak A3/Speed 0300
CLEANING ICU (Integrated Cleaning Unit) Cold water supply, I/h Flow, It/h Consumptions: Cold water, I/cycle Steam, kg/h
3
359
Min 3000 Min 8000 350 7 2346
Water supply, kPa (bar): Water max inlet temperature,°C (°F): Detergent pH Consumptions: Water, I/cycle Detergent, I/cycle
300-450 (3-4,5) 20 to 25 (68 to 77) 10-12
67
15
75
250 1,2
6052 (at open lid)
EXTERNAL CLEANING
06
02
18
10
11
WORKING ENVIRONMENT TEMPERATURE* Min temperature °C (°F): Max temperature °C (°F): Recommended temperature °C (°F)
5 (41) 50 (122) 15-30 (59-86)
*(temperature measured at the EC Cooler air inlet area)
OPTIONAL EQUIPMENT/OPTIONAL KIT PullTab - available as OE Stair RH - available as OE Headspace by Injection - available as OE and OK
INSTALLATION DRAWING NO. Tetra Pak A3/Speed: Tetra Pak A3/Speed with PullTab:
648576-3 648576-4
CERTIFICATIONS: FDA filed CE 3A
www.tetrapak.com We reserve the right to introduce design modifications without prior notice, Tetra Pak, , protects what’s good are trademarks belonging to the Tetra Pak Group. Tetra Pak Packaging Solutions / ADCode 0710S en. Date 07/2010
Dimensions: External measurements (mm):
- Tetra Pak A3/Speed (without PullTab): - Tetra Pak A3/Speed (with PullTab):
7506 9328
Packaging for shipping boxes: External measurements (mm):
L D H
- Tetra Pak A3/Speed (without PullTab).... 4800 2100 2870 3300 2100 2870 4200 2400 2950 . - Tetra Pak A3/Speed (with PullTab)......... 4800 2100 2870 3300 2100 2870 4200 2400 2950