Autmation System Layout Diagram - A [PDF]

  • 0 0 0
  • Gefällt Ihnen dieses papier und der download? Sie können Ihre eigene PDF-Datei in wenigen Minuten kostenlos online veröffentlichen! Anmelden
Datei wird geladen, bitte warten...
Zitiervorschau

Status: Approved

Confidential 1

2 Drw No

3

Page No

Revision

4

Document id: DBAE559710 a Page 1 (15) 5

6

7

8

Drawing

A

A CC90000

1/1

-/2017-08-30

LIST OF DRAWINGS, CC90000 - CC90087

CC90010

1/1

-/2017-08-30

MOUNTING INSTRUCTIONS

CC90025

1/1

-/2017-08-30

EARTHING DIAGRAM

CC90031

1/4 2/4 3/4 4/4

-/2017-08-30 -/2017-08-30 -/2017-08-30 -/2017-08-30

BETWEEN GENSETS, AVR VOLTAGE DROOP COMPENSATION LINES BETWEEN GENSETS, AVR VOLTAGE DROOP COMPENSATION LINES BETWEEN GENSETS, SPEED CONTROLLER LOAD SHARING LINES BETWEEN GENSETS, SPEED CONTROLLER LOAD SHARING LINES

CC90050

1/7 2/7 3/7 4/7 5/7 6/7 7/7

-/2017-08-30 -/2017-08-30 -/2017-08-30 -/2017-08-30 -/2017-08-30 -/2017-08-30 -/2017-08-30

AUTOMATION SYSTEM LAYOUT, COMMON CONTROL PANEL AUTOMATION SYSTEM LAYOUT, COMMON CONTROL PANEL AUTOMATION SYSTEM LAYOUT, GENERATING SET AUTOMATION SYSTEM LAYOUT, GENERATING SET AUTOMATION SYSTEM LAYOUT, GENERATING SET AUTOMATION SYSTEM LAYOUT, GENERATING SET AUTOMATION SYSTEM LAYOUT, AC SUPPLY FOR PC’s AND PRINTER’S

CC90087

1/1

-/2017-08-30

LIST OF GROUNDING CABLES, GND01 - GND11

B

B

C

C

D

D

E

E

Product

F

Made Chkd Appr.

CAD

2017-08-30

Petri Nikko JaR AL

1:1

CHANDPUR 200 MW POWER PLANT BANGLADESH OIL POWER PLANT

COMMON PART LIST OF DRAWINGS CC90000 - CC90087

Other Ident.

Assy ident.

+COMMON Other Ident.

Sheet/ sheets

F

1/ 1 Drawing ident.

KD.16045 - CC90000

Rev.

-

This drawing is the property of Wärtsilä and shall neither be copied, shown nor communicated to a third party without the consent of the owner.

Status: Approved

Confidential 1

2

3

4

Document id: DBAE559710 a Page 2 (15) 5

6

7

8

Note! Transporting control panels A

A

Panels can be transported by a forklift or a crane. Make sure that the control panel(s) do not topple or fall.

Section Width Depth Height Weight CFA901 4606mm 605mm 2205+100mm 1000kg 4606mm 605mm 2205+100mm 1000kg

B

Side wall

Side wall

Chkd Appr.

603mm 600mm 600mm 600mm 600mm 603mm 3606mm

605mm 605mm 605mm 605mm 605mm 605mm 605mm

2205+100mm 2205+100mm 2205+100mm 2205+100mm 2205+100mm 2205+100mm 2205+100mm

250kg 250kg 250kg 250kg 250kg 250kg 1500kg

B

C

CFC091

CFC031

CFC101

CFC021

D

CFC111

E

CFC121 CAD

2017-08-30

CFC071 CFC081 CFC091 CFC101 CFC111 CFC121

Transport break

CFC011 Product Made

250kg 250kg 250kg 250kg 250kg 250kg 1500kg

CFA901

Side wall

F

2205+100mm 2205+100mm 2205+100mm 2205+100mm 2205+100mm 2205+100mm 2205+100mm

CFC071 CFA901

CFC041

Side wall

Transport break

E

605mm 605mm 605mm 605mm 605mm 605mm 605mm

CFC081

CFC051

CFA901

D

603mm 600mm 600mm 600mm 600mm 603mm 3606mm

Side wall

CFC061

C

CFC011 CFC021 CFC031 CFC041 CFC051 CFC061

Petri Nikko JaR AL

Side wall

1:25

CHANDPUR 200 MW POWER PLANT BANGLADESH

COMMON PART MOUNTING INSTRUCTIONS

Other Ident.

Sheet/ sheets

F

1/1 Drawing ident.

OIL POWER PLANT

Assy ident.

+COMMON Other Ident.

KD.16045 - CC90010

Rev.

-

This drawing is the property of Wärtsilä and shall neither be copied, shown nor communicated to a third party without the consent of the owner.

Status: Approved

Confidential 1

2

3

Document id: DBAE559710 a Page 3 (15)

4

5

6

7

8

A

A From plant main earthing busbar 1

GND01 1G25

1

GND02 1G25

1

GND03 1G25

1

GND04 1G25

1

GND05 1G25

1

GND06 1G25

1

GND07.1 1G25

1

GND07 1G25

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

PE/0

PE/0

PE/0

PE/0

PE/0

PE/0

PE/0

PE/0

PE/0

PE/0

PE/0

PE/0

PE/0

PE/0

PE/0

PE/0

PE/0

PE/0

>+CFC011

B

>+CFC021

>+CFC031

>+CFC041 Transport break

>+CFC051

>+CFC061

>+CFA901 Transport break

>+CFC071

GND08 1G25

1

>+CFC081

B

Transport break

From plant main earthing busbar

C

1

1 PE/0

GND09 1G25

1

2

1

PE/0

PE/0

>+CFC091

GND10 1G25

1

2

1

PE/0

PE/0

>+CFC101

C

GND11 1G25

2

1

PE/0

PE/0

>+CFC111

2 PE/0

>+CFC121

Transport break

D

D

E

E

Product

F

Made Chkd Appr.

CAD

2017-08-30

Petri Nikko JaR AL

1:1

CHANDPUR 200 MW POWER PLANT BANGLADESH

COMMON PART EARTHING DIAGRAM

Other Ident.

Sheet/ sheets

F

1/1 Drawing ident.

OIL POWER PLANT

Assy ident.

+COMMON Other Ident.

KD.16045 - CC90025

Rev.

-

This drawing is the property of Wärtsilä and shall neither be copied, shown nor communicated to a third party without the consent of the owner.

Status: Approved

Confidential 1

A

2

3

>+CFE011

4

5

>+CFE021

U1

Document id: DBAE559710 a Page 4 (15)

X1302

RS-485

7

>+CFE031

U1

X1300

6

CAN

>+CFE041

U1

X1300

X1302

RS-485

8

U1

X1300

CAN

A

X1302

RS-485

X1300

CAN

X1302

RS-485

CAN

RH

RL

RS

RH

RL

RS

RH

RL

RS

RH

RL

RS

70

74

72

70

74

72

70

74

72

70

74

72

B

B TE/2

1a

1b 1g 2a

TE/2

TE/2

2b

2g

TE/2

1a

1b

2a

1a

2b

1b 1g 2a

TE/2

TE/2

2b

2g

TE/2

1a

1b

2a

2b

1a

1b 1g 2a

TE/2

TE/2

2b

2g

TE/2

1a

1b

2a

2b

1a

1b 1g 2a

TE/2

TE/2

2b

2g

Note! Jumpers enabled

Jumpers disabled

G

PE/2

G

G

G

C

C 11227 4x(2+1)x0.5+0.5

12227 4x(2+1)x0.5+0.5

>+CFE051

13227 4x(2+1)x0.5+0.5

14227 4x(2+1)x0.5+0.5

>+CFE061

U1

U1

X1300

X1302

X1300

X1302

D

D RS-485

CAN

RS-485

RH

RL

RS

RH

RL

RS

70

74

72

70

74

72

TE/2

1a

1b

CAN

2a

2b

1a

1b 1g 2a

TE/2

TE/2

2b

2g

1a

1b

2a

2b

E

E

G

15227 4x(2+1)x0.5+0.5

Note! Check termination resistor jumper X1300 (Jumpers to be enabled only on first and last device of the VDC-net)

Product

F

Made Chkd Appr.

CAD

2017-08-30

Petri Nikko JaR AL

1:1

CHANDPUR 200 MW POWER PLANT BANGLADESH OIL POWER PLANT

COMMON PART BETWEEN GENSETS AVR VOLTAGE DROOP COMPENSATION LINES

Other Ident.

Assy ident.

+COMMON Other Ident.

Sheet/ sheets

F

1/4 Drawing ident.

KD.16045 - CC90031

Rev.

-

This drawing is the property of Wärtsilä and shall neither be copied, shown nor communicated to a third party without the consent of the owner.

Status: Approved

Confidential 1

A

2

3

>+CFE071

4

5

>+CFE081

U1

Document id: DBAE559710 a Page 5 (15)

X1302

RS-485

7

>+CFE091

U1

X1300

6

CAN

>+CFE101

U1

X1300

X1302

RS-485

8

U1

X1300

CAN

A

X1302

RS-485

X1300

CAN

X1302

RS-485

CAN

RH

RL

RS

RH

RL

RS

RH

RL

RS

RH

RL

RS

70

74

72

70

74

72

70

74

72

70

74

72

B

B TE/2

1a

1b 1g 2a

TE/2

TE/2

2b

2g

TE/2

1a

1b

2a

1a

2b

1b 1g 2a

TE/2

TE/2

2b

2g

TE/2

1a

1b

2a

2b

1a

1b 1g 2a

TE/2

TE/2

2b

2g

TE/2

1a

1b

2a

2b

1a

1b 1g 2a

TE/2

TE/2

2b

2g

Note! Jumpers enabled

Jumpers disabled

G

PE/2

G

G

G

C

C 17227 4x(2+1)x0.5+0.5

18227 4x(2+1)x0.5+0.5

>+CFE111

19227 4x(2+1)x0.5+0.5

20227 4x(2+1)x0.5+0.5

>+CFE121

U1

U1

X1300

X1302

X1300

X1302

D

D RS-485

CAN

RS-485

RH

RL

RS

RH

RL

RS

70

74

72

70

74

72

TE/2

1a

1b

CAN

2a

2b

1a

1b 1g 2a

TE/2

TE/2

2b

2g

1a

1b

2a

2b

E

E

G

21227 4x(2+1)x0.5+0.5

Note! Check termination resistor jumper X1300 (Jumpers to be enabled only on first and last device of the VDC-net)

Product

F

Made Chkd Appr.

CAD

2017-08-30

Petri Nikko JaR AL

1:1

CHANDPUR 200 MW POWER PLANT BANGLADESH OIL POWER PLANT

COMMON PART BETWEEN GENSETS AVR VOLTAGE DROOP COMPENSATION LINES

Other Ident.

Assy ident.

+COMMON Other Ident.

Sheet/ sheets

F

2/4 Drawing ident.

KD.16045 - CC90031

Rev.

-

This drawing is the property of Wärtsilä and shall neither be copied, shown nor communicated to a third party without the consent of the owner.

Status: Approved

Confidential 1

A

2

>+ENGINE #1

3

4

>+ENGINE #2

MCM

X34.6

PE

X34.5

5

>+ENGINE #3

MCM

X34.5

Document id: DBAE559710 a Page 6 (15)

PE

X34.5

7

>+ENGINE #4

MCM

X34.6

6

>+ENGINE #5

MCM

X34.6

PE

X34.5

8

A

MCM

X34.6

PE

X34.5

X34.6

PE

B

R

120

B

1a

1b

G

1a

1b

1a

1b

G

1a

1b

1a

1b

1a

G

1b

1a

1b

G

1a

1b

1a

1b

G

C

C 11502 2x0.5+0.5

12502 2x0.5+0.5

13502 2x0.5+0.5

14502 2x0.5+0.5

15502 2x0.5+0.5

>+ENGINE #6

MCM

D

D

X34.6

1a

1b

PE

120

R

X34.5

E

E

Note! Use termination resistor 120 Ohm in both ends of the CAN bus

Product

F

Made Chkd Appr.

CAD

2017-08-30

Petri Nikko JaR AL

1:1

CHANDPUR 200 MW POWER PLANT BANGLADESH OIL POWER PLANT

COMMON PART BETWEEN GENSETS SPEED CONTROLLER LOAD SHARING LINES

Other Ident.

Assy ident.

+COMMON Other Ident.

Sheet/ sheets

F

3/4 Drawing ident.

KD.16045 - CC90031

Rev.

-

This drawing is the property of Wärtsilä and shall neither be copied, shown nor communicated to a third party without the consent of the owner.

Status: Approved

Confidential 1

A

2

>+ENGINE #7

3

4

>+ENGINE #8

MCM

X34.6

PE

X34.5

5

>+ENGINE #9

MCM

X34.5

Document id: DBAE559710 a Page 7 (15)

PE

X34.5

7

>+ENGINE #10

MCM

X34.6

6

>+ENGINE #11

MCM

X34.6

PE

X34.5

8

A

MCM

X34.6

PE

X34.5

X34.6

PE

B

R

120

B

1a

1b

G

1a

1b

1a

1b

G

1a

1b

1a

1b

1a

G

1b

1a

1b

G

1a

1b

1a

1b

G

C

C 17502 2x0.5+0.5

18502 2x0.5+0.5

19502 2x0.5+0.5

20502 2x0.5+0.5

21502 2x0.5+0.5

>+ENGINE #12

MCM

D

D

X34.6

1a

1b

PE

120

R

X34.5

E

E

Note! Use termination resistor 120 Ohm in both ends of the CAN bus

Product

F

Made Chkd Appr.

CAD

2017-08-30

Petri Nikko JaR AL

1:1

CHANDPUR 200 MW POWER PLANT BANGLADESH OIL POWER PLANT

COMMON PART BETWEEN GENSETS SPEED CONTROLLER LOAD SHARING LINES

Other Ident.

Assy ident.

+COMMON Other Ident.

Sheet/ sheets

F

4/4 Drawing ident.

KD.16045 - CC90031

Rev.

-

This drawing is the property of Wärtsilä and shall neither be copied, shown nor communicated to a third party without the consent of the owner.

Status: Approved

Confidential 1

2

>+CWA901 >+CWS901

A

3

>+CWA902 >+CWS902

WOIS

4

>+CWA903 >+CWS903

WOIS

5

6

7

8

>+CWF901 >+CWS905

>+CWA904 >+CWS904

WOIS

Document id: DBAE559710 a Page 8 (15)

WISE

WOIS

A

>+CWP901

SFTP

59136

SFTP

59135

SFTP

59134

59133

SFTP

SFTP

59132

SFTP

59131

Hardcopy & report printer

>+CFA901

B

B AF15

AF16 3

7 1

AG1

AG1.3

4

3 Switch

2

2

8

AF1

GPS

5

6

Switch 8

AF2

AF3

1

59173

4

1

Control Room Segment Router

G1

G2

Control Room Segment Router

G1

G2

59174

4

59102 FO Ethernet

C12

Common Segment Router 3 2 1

5

G1

59101

6/7A

C01

3/1A

FO Ethernet

AF11

out

C

Maintenance access firewall

WAN

in

LAN

AG1.2

C

Installed to engine hall roof

G2

AF11.1

A1

AF8 1

PLC

Switch 2

3

4

5

6

7

59153 SFTP

>+BEY901 Common 24VDC system

A2

D

59154 SFTP

D

>+BEY902 Common 24VDC system

Remote IO 59155 SFTP

>+BEY903 Common 24VDC system

59156 SFTP

A3

>+BEY904 Common 110VDC system

59157

Remote IO

SFTP

>+BEY905 Common 110VDC system

59158 SFTP

>+BEY906 Common 110VDC system

AF5

E

59151 FO Ethernet

CFA902_1_FO

E 2/1B

Note! Only external communication cables marked

Product

F

Made Chkd Appr.

CAD

2017-08-30

Petri Nikko JaR AL

1:1

CHANDPUR 200 MW POWER PLANT BANGLADESH OIL POWER PLANT

COMMON PART AUTOMATION SYSTEM LAYOUT COMMON CONTROL PANEL

Other Ident.

Assy ident.

+COMMON Other Ident.

Sheet/ sheets

F

1/7 Drawing ident.

KD.16045 - CC90050

Rev.

-

This drawing is the property of Wärtsilä and shall neither be copied, shown nor communicated to a third party without the consent of the owner.

Status: Approved

Confidential 1

2

3

Document id: DBAE559710 a Page 9 (15)

4

5

6

7

8

A

A

B

B 1/7E

CFA902_1_FO

>+CFA902 AF5 Media converter

>+BJL901

C AF1

AF6 2

Switch 1

8

Media converter

3 5

4

59201 SFTP

P3

DBAE548879:7 AF7

>+BJL902 -A1

Media converter

59202

P3

SFTP

>+BJL903 AF8

DBAE546913:7

-A1

Media converter

D

C

-A1

59203 SFTP

D

P3

DBAE547174:7

A1

TF1 Remote IO

>+Flow meter

E

E

Note! Only external communication cables marked

Product

F

Made Chkd Appr.

CAD

2017-08-30

Petri Nikko JaR AL

1:1

CHANDPUR 200 MW POWER PLANT BANGLADESH OIL POWER PLANT

COMMON PART AUTOMATION SYSTEM LAYOUT COMMON CONTROL PANEL

Other Ident.

Assy ident.

+COMMON Other Ident.

Sheet/ sheets

F

2/7 Drawing ident.

KD.16045 - CC90050

Rev.

-

This drawing is the property of Wärtsilä and shall neither be copied, shown nor communicated to a third party without the consent of the owner.

Status: Approved

Confidential 1

2

1/6C

C01

3

Document id: DBAE559710 a Page 10 (15)

4

5

59552

59557

FO Ethernet

FO Ethernet

6

7

1

8 C03

59562 FO Ethernet

4/1A

A

A >+CFC011

>+CFC021 P11

AF5

G1 G2

Router

AF1

PMU 6

P11

Router

PMU

A1

PLC K2

59558

>+BLP011

AF5 Media converter

Switch 4

>+BJA031 AF1

AF5 Media converter

Switch 4

TF1 A1

Remote IO

A1

Interface converter

>+CFE011

59861

>+PCA011-Q001 Flow meter

See LV03250:2

SFTP

59856

See LV02250:2

SFTP

59851

4

Remote IO

See LV01250:2

>+PCA021-Q001 Flow meter

>+CFE021 AF1

3

3

Switch

Switch

5

5

5

A1 U1

Remote IO AVR

A1 U1

U1

Remote IO AVR

>+ENGINE_01

E 59701

AVR >+ENGINE_02

59706

UNIC-C3

SFTP

D

AF1

3

Switch A1

>+PCA031-Q001 Flow meter

>+CFE031 AF1

Remote IO

C

Switch TF1

Interface converter

Remote IO

D

AF1

TF1

Interface converter

B >+BLP031

SFTP

59561

>+BJA021 AF1

59563

FO Ethernet

59556

Diff prot. relay >+BLP021

SFTP

FO Ethernet

>+BJA011

A1

Prot. relay

Diff prot. relay

SFTP

59551

A1

K2

Diff prot. relay

Media converter

PMU 6

PLC

59553

C

Router K1

Prot. relay

K2

B

P11 G1 G2

K1 Prot. relay

PLC

AF5

AF1

Media converter

6

K1 A1

AF5

G1 G2

Media converter

SFTP

AF1

Media converter

FO Ethernet

AF5

>+CFC031

SFTP

>+ENGINE_03 59711

UNIC-C3

SFTP

E

UNIC-C3

Note! Only external communication cables marked

Product

F

Made Chkd Appr.

CAD

2017-08-30

Petri Nikko JaR AL

1:1

CHANDPUR 200 MW POWER PLANT BANGLADESH OIL POWER PLANT

COMMON PART AUTOMATION SYSTEM LAYOUT GENERATING SET

Other Ident.

Assy ident.

+COMMON Other Ident.

Sheet/ sheets

F

3/7 Drawing ident.

KD.16045 - CC90050

Rev.

-

This drawing is the property of Wärtsilä and shall neither be copied, shown nor communicated to a third party without the consent of the owner.

Status: Approved

Confidential 1

2

3/7A

C03

3

Document id: DBAE559710 a Page 11 (15)

4

5

59567

59572

FO Ethernet

FO Ethernet

6

7

1

8 C06

59577 FO Ethernet

5/1A

A

A >+CFC041

>+CFC051 P11

AF5

G1 G2

Router

AF1

PMU 6

P11

Router

PMU

A1

PLC K2

59573

>+BLP041

AF5 Media converter

Switch 4

>+BJA061 AF1

AF5 Media converter

Switch 4

TF1 A1

Remote IO

A1

Interface converter

>+CFE041

59876

>+PCA041-Q001 Flow meter

See LV06250:2

SFTP

59871

See LV05250:2

SFTP

59866

4

Remote IO

See LV04250:2

>+PCA051-Q001 Flow meter

>+CFE051 AF1

3

3

Switch

Switch

5

5

5

A1 U1

Remote IO AVR

A1 U1

U1

Remote IO AVR

>+ENGINE_04

E 59716

AVR >+ENGINE_05

59721

UNIC-C3

SFTP

D

AF1

3

Switch A1

>+PCA061-Q001 Flow meter

>+CFE061 AF1

Remote IO

C

Switch TF1

Interface converter

Remote IO

D

AF1

TF1

Interface converter

B >+BLP061

SFTP

59576

>+BJA051 AF1

59578

FO Ethernet

59571

Diff prot. relay >+BLP051

SFTP

FO Ethernet

>+BJA041

A1

Prot. relay

Diff prot. relay

SFTP

59566

A1

K2

Diff prot. relay

Media converter

PMU 6

PLC

59568

C

Router K1

Prot. relay

K2

B

P11 G1 G2

K1 Prot. relay

PLC

AF5

AF1

Media converter

6

K1 A1

AF5

G1 G2

Media converter

SFTP

AF1

Media converter

FO Ethernet

AF5

>+CFC061

SFTP

>+ENGINE_06 59726

UNIC-C3

SFTP

E

UNIC-C3

Note! Only external communication cables marked

Product

F

Made Chkd Appr.

CAD

2017-08-30

Petri Nikko JaR AL

1:1

CHANDPUR 200 MW POWER PLANT BANGLADESH OIL POWER PLANT

COMMON PART AUTOMATION SYSTEM LAYOUT GENERATING SET

Other Ident.

Assy ident.

+COMMON Other Ident.

Sheet/ sheets

F

4/7 Drawing ident.

KD.16045 - CC90050

Rev.

-

This drawing is the property of Wärtsilä and shall neither be copied, shown nor communicated to a third party without the consent of the owner.

Status: Approved

Confidential 1

2

4/7A

C06

3

Document id: DBAE559710 a Page 12 (15)

4

5

59582

59587

FO Ethernet

FO Ethernet

6

7

1

8 C09

59592 FO Ethernet

6/1A

A

A >+CFC071

>+CFC081 P11

AF5

G1 G2

Router

AF1

PMU 6

P11

Router

PMU

A1

PLC K2

59588

>+BLP071

AF5 Media converter

Switch 4

>+BJA091 AF1

AF5 Media converter

Switch 4

TF1 A1

Remote IO

A1

Interface converter

>+CFE071

59891

>+PCA071-Q001 Flow meter

See LV09250:2

SFTP

59886

See LV08250:2

SFTP

59881

4

Remote IO

See LV07250:2

>+PCA081-Q001 Flow meter

>+CFE081 AF1

3

3

Switch

Switch

5

5

5

A1 U1

Remote IO AVR

A1 U1

U1

Remote IO AVR

>+ENGINE_07

E 59731

AVR >+ENGINE_08

59736

UNIC-C3

SFTP

D

AF1

3

Switch A1

>+PCA091-Q001 Flow meter

>+CFE091 AF1

Remote IO

C

Switch TF1

Interface converter

Remote IO

D

AF1

TF1

Interface converter

B >+BLP091

SFTP

59591

>+BJA081 AF1

59593

FO Ethernet

59586

Diff prot. relay >+BLP081

SFTP

FO Ethernet

>+BJA071

A1

Prot. relay

Diff prot. relay

SFTP

59581

A1

K2

Diff prot. relay

Media converter

PMU 6

PLC

59583

C

Router K1

Prot. relay

K2

B

P11 G1 G2

K1 Prot. relay

PLC

AF5

AF1

Media converter

6

K1 A1

AF5

G1 G2

Media converter

SFTP

AF1

Media converter

FO Ethernet

AF5

>+CFC091

SFTP

>+ENGINE_09 59741

UNIC-C3

SFTP

E

UNIC-C3

Note! Only external communication cables marked

Product

F

Made Chkd Appr.

CAD

2017-08-30

Petri Nikko JaR AL

1:1

CHANDPUR 200 MW POWER PLANT BANGLADESH OIL POWER PLANT

COMMON PART AUTOMATION SYSTEM LAYOUT GENERATING SET

Other Ident.

Assy ident.

+COMMON Other Ident.

Sheet/ sheets

F

5/7 Drawing ident.

KD.16045 - CC90050

Rev.

-

This drawing is the property of Wärtsilä and shall neither be copied, shown nor communicated to a third party without the consent of the owner.

Status: Approved

Confidential 1

2

5/7A

C09

3

Document id: DBAE559710 a Page 13 (15)

4

5

59597

59602

FO Ethernet

FO Ethernet

6

7

1

8 C12

59607 _

1/3C

A

A >+CFC101

>+CFC111 P11

AF5

G1 G2

Router

AF1

PMU 6

P11

Router

PMU

A1

PLC K2

59603

>+BLP101

AF5 Media converter

Switch 4

>+BJA121 AF1

AF5 Media converter

Switch 4

TF1 A1

Remote IO

A1

Interface converter

>+CFE101

59906

>+PCA101-Q001 Flow meter

See LV12250:2

SFTP

59901

See LV11250:2

SFTP

59896

4

Remote IO

See LV10250:2

>+PCA111-Q001 Flow meter

>+CFE111 AF1

3

3

Switch

Switch

5

5

5

A1 U1

Remote IO AVR

A1 U1

U1

Remote IO AVR

>+ENGINE_10

E 59746

AVR >+ENGINE_11

59751

UNIC-C3

SFTP

D

AF1

3

Switch A1

>+PCA121-Q001 Flow meter

>+CFE121 AF1

Remote IO

C

Switch TF1

Interface converter

Remote IO

D

AF1

TF1

Interface converter

B >+BLP121

SFTP

59606

>+BJA111 AF1

59608

FO Ethernet

59601

Diff prot. relay >+BLP111

SFTP

FO Ethernet

>+BJA101

A1

Prot. relay

Diff prot. relay

SFTP

59596

A1

K2

Diff prot. relay

Media converter

PMU 6

PLC

59598

C

Router K1

Prot. relay

K2

B

P11 G1 G2

K1 Prot. relay

PLC

AF5

AF1

Media converter

6

K1 A1

AF5

G1 G2

Media converter

SFTP

AF1

Media converter

FO Ethernet

AF5

>+CFC121

SFTP

>+ENGINE_12 59756

UNIC-C3

SFTP

E

UNIC-C3

Note! Only external communication cables marked

Product

F

Made Chkd Appr.

CAD

2017-08-30

Petri Nikko JaR AL

1:1

CHANDPUR 200 MW POWER PLANT BANGLADESH OIL POWER PLANT

COMMON PART AUTOMATION SYSTEM LAYOUT GENERATING SET

Other Ident.

Assy ident.

+COMMON Other Ident.

Sheet/ sheets

F

6/7 Drawing ident.

KD.16045 - CC90050

Rev.

-

This drawing is the property of Wärtsilä and shall neither be copied, shown nor communicated to a third party without the consent of the owner.

Status: Approved

Confidential 1

2

3

CWA901

A

4

CWS901

CWA902

Hardcopy & report printer

5

CWS902

WOIS

CWP901

Document id: DBAE559710 a Page 14 (15)

CWA903

CWS903

WOIS

Supervision PC

6

7

CWA904

CWS904

WOIS

Supervision PC

Supervision PC

8

CWF901

CWS905

WOIS

A

WISE

Supervision PC

Report PC

B

B

+E1

C

C L

1

N

2

PE

L

N

PE

L

3

1

2

3

1

2

3

L

N

PE

L

N

PE

1

2

3

N

PE

L

N

PE

L

N

PE

L

N

PE

D

D BEU901 BEU901.1

UPS

Prefabricated cable

E

1

2

61XXX 3x2.5S

Product

F

Made Chkd Appr.

CAD

2017-08-30

Petri Nikko JaR AL

1:1

E

3

BFA90x 230 VAC (Fxx)

CHANDPUR 200 MW POWER PLANT BANGLADESH OIL POWER PLANT

COMMON PART AUTOMATION SYSTEM LAYOUT AC SUPPLY FOR PC’s AND PRINTER’S

Other Ident.

Assy ident.

+COMMON Other Ident.

Sheet/ sheets

F

7/7 Drawing ident.

KD.16045 - CC90050

Rev.

-

This drawing is the property of Wärtsilä and shall neither be copied, shown nor communicated to a third party without the consent of the owner.

Status: Approved

Confidential 1

No

2 Type

3 Len

From

4 Drw No

Document id: DBAE559710 a Page 15 (15) 5

To

6

7

Drw No

8 Note!

A

B

A GND01

1G25

+CFC011-PE/0:2

CC90025:1

+CFC021-PE/0:1, Earthing cable between panels

CC90025:1

Installed at factory

GND02

1G25

+CFC021-PE/0:2

CC90025:1

+CFC031-PE/0:1, Earthing cable between panels

CC90025:1

Installed at factory

GND03

1G25

+CFC031-PE/0:2

CC90025:1

+CFC041-PE/0:1, Earthing cable between panels

CC90025:1

Installed at factory

GND04

1G25

+CFC041-PE/0:2

CC90025:1

+CFC051-PE/0:1, Earthing cable between panels

CC90025:1

Installed at factory

GND05

1G25

+CFC051-PE/0:2

CC90025:1

+CFC061-PE/0:1, Earthing cable between panels

CC90025:1

Installed at factory

GND06

1G25

+CFC061-PE/0:2

CC90025:1

+CFA901-PE/0:1, Earthing cable between panels

CC90025:1

Installed at factory

GND07

1G25

+CFC071-PE/0:2

CC90025:1

+CFC081-PE/0:1, Earthing cable between panels

CC90025:1

Installed at factory

GND07.1

1G25

+CFA901-PE/0:2

CC90025:1

+CFC071-PE/0:1, Earthing cable between panels

CC90025:1

Installed at factory

GND08

1G25

+CFC081-PE/0:2

CC90025:1

+CFC091-PE/0:1, Earthing cable between panels

CC90025:1

Installed at factory

GND09

1G25

+CFC091-PE/0:2

CC90025:1

+CFC101-PE/0:1, Earthing cable between panels

CC90025:1

Installed at factory

GND10

1G25

+CFC101-PE/0:2

CC90025:1

+CFC111-PE/0:1, Earthing cable between panels

CC90025:1

Installed at factory

GND11

1G25

+CFC111-PE/0:2

CC90025:1

+CFC121-PE/0:1, Earthing cable between panels

CC90025:1

Installed at factory

B

C

C

D

D

E

E

NOTE! Cable type and size is just for reference Product

F

Made Chkd Appr.

CAD

2017-08-30

Petri Nikko JaR AL

1:1

CHANDPUR 200 MW POWER PLANT BANGLADESH OIL POWER PLANT

COMMON PART LIST OF GROUNDING CABLES GND01 - GND11

Other Ident.

Assy ident.

+COMMON Other Ident.

Sheet/ sheets

F

1/ 1 Drawing ident.

KD.16045 - CC90087

Rev.

-

This drawing is the property of Wärtsilä and shall neither be copied, shown nor communicated to a third party without the consent of the owner.