Remote Terminal Unit-5/03 Processor with Modbus Slave on Channel 0 3250-L532M

The ProSoft RTU-5/03 processor, aimed strategically at the SCADA marketplace, is a Rockwell Automation SLC 5/03 processor that has been modified to include the Modbus Slave protocol developed in Channel 0.

Features and Benefits Remote Terminal Unit-5/03 Processor with Modbus Slave on Channel 0 3250-L532M • • • • •

Oil & gas Pipeline Off-shore platforms Water/ waste water Power utility and mining

How to Contact Us: Sales and Support

All ProSoft Technology products are backed with unlimited technical support. Contact our worldwide Technical Support team directly by phone or email: Asia Pacific +603.7724.2080, [email protected] Languages spoken include: Chinese, Japanese, English Europe – Middle East – Africa +33 (0) 5.34.36.87.20, [email protected] Languages spoken include: French, English North America +1.661.716.5100, [email protected] Languages spoken include: English, Spanish Latin America (Sales only) +1.281.298.9109, [email protected] Languages spoken include: Spanish, English Brasil +55-11.5084.5178, [email protected] Languages spoken include: Portuguese, English

The full SLC command set functionality is available, and the unit is programmed with standard ladder programming tools (RS Logix and APS). The Modbus Slave protocol is enabled with the simple addition and setup of an Integer file at N100. This file configures the Channel 0 Modbus driver and allows user control over the operation of the port. In addition, extensive diagnostic data is returned from the driver to the integer file, allowing access to troubleshooting data. After the Modbus protocol is activated, a Modbus host can read and write data from all the common Modbus data types (binary in and out, analog in, and holding registers). In addition, support has been provided for the transfer of floating-point data, which optionally uses the 'Enron' addressing range. A host can also access the processor status file S2 to remotely monitor the health of the unit or to do such things as set the real time clock.

General Specifications

The ProSoft Technology, Inc. RTU-5/03 processor solution includes the following features: • • • • • •

Channel 0 port supports Modbus Slave protocol Modbus read and write of binary, integer, and floating-point data types Modbus Master can read from or write to the processor Status File (S2) RS-232C handshaking for SCADA radio/modem applications Satellite and Packet Radio support with a configurable Inter-Character Timeout Channel 0 Modbus Port configuration through entry of configuration values in Modbus Configuration and Diagnostic File (N100) in ladder logic: o Slave Addr : 1 to 127 (0 is broadcast) o Parity : None, odd, or even o Stop Bit : 1 or 2 o Baud Rate : 300 to 19,200 o RTS Send Delay: 0 to 2500 ms o RTS Off Delay : 0 to 2500 ms o Pre-Send Delay : 0 to 2500 ms o Inter-character : 0 to 2500 ms

Functional Specifications

The RTU-5/03 incorporates the Allen-Bradley SLC-5/03 technology. As such, it has all the standard features of the SLC 5/03, including: • DF1 programming support (uses standard ladder logic tools for programming on Channel 0) • Auto switch between DF1 and Modbus on Channel 0 • DH-485 network access and programming on Channel 1 • Up to 1024 inputs plus 1024 outputs • 16K (3250-L532M) word memory configurations • Floating-point math support • On-line programming • Run-time editing • Built-in key switch • Built-in real-time clock and calendar

Modbus Slave Specifications • •



Modbus protocol modes: o RTU (binary) with CRC-16 error checking o ASCII with LRC error checking (7 and 8 bit) Supported Modbus function codes: o 1: read output status o 2: read input status o 3: read multiple data registers o 4: read input registers o 5: force single coil (latch/unlatch) o 6: write single data register o 8: loop back test, test 0 only o 15: multiple coil latch/unlatch o 16: Write multiple data registers Supports broadcast commands form the Master

Specification

Description

Backplane Current Load

500 mA @ 5 Vdc 175 mA @ 24 Vdc 0°C to 60°C (32°F to 140°F) –40°C to 85°C (–40°F to 185°F) 30 g operational 50 g non-operational 5% to 95% (with no condensation) 5 g from 10 to 150 Hz RUN FORCE FLT DH485 BATT MODBUS (RS232)

Operating Temperature Storage Temperature Shock Relative Humidity Vibration LED indicators Processor Ports

Connectors and Usage

Channel 1 (DH485 Port)

RJ45 jack Used for SLC Programming and DH485 Communication DB-9 Male Used for SLC Programming and DF1 or Modbus Communication

Channel 0 (RS232C Port)

Additional Products

ProSoft Technology offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. Visit our web site at http://www.prosoft-technology.com for a complete list of products.

Ordering Information

To order this product, please use the following: 3250-L532M

Remote Terminal Unit SLC 5/03 Processor with Modbus Slave on Channel 0

To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft distributors near you, go to http://www.prosoft-technology.com Distributors: Place your order by email or fax to: North American / Latin American / Asia Pacific [email protected], fax to +1 661.716.5101 Europe [email protected], fax to +33 (0) 5.61.78.40.52 Copyright © ProSoft Technology, Inc. 2000 - 2007. All Rights Reserved. January 19, 2007