30 0 408KB
8
TCR ARABIA COMPANY LIMITED PHASED ARRAY ULTRASONIC TESTING REPORT Client Project Location
ABENGOA (J3A) Independent Water Project JUBAIL
Test Procedure Technique Sheet No. Acceptance Standard
QCP/TCR/PAUT-004 REV.0 ASME B31.3
Date of Inspection Report No. Page No.
November 01,2022 RP-22-PAUT-261-TCR- ABENGOA 1 of 4
EQUIPMENT & MATERIAL SPECIFICATION Maker
Model
Serial No.
Cable Type
Software
Ref. Block
Cal. Block
Couplant
Material
Thickness
Item Specification
Accessible Area
Surface Condition
RD Tech Olympus
OmniScan MX 2
Omni 104494
Ambli Cable 2.5OM
OMNI PC / Tomoview 2.10R16
7.92 mm 2mm SDH
IIW V1 BLOCK
Chemetall UltraGel
SS
9.53mm
16” Pipe RACK 09
One side
Rough surface
SEARCH UNIT IDENTIFICATION & CALIBRATION SETTINGS Channel
Skew
Probe ID
Wedge
Min. Angle
Max. Angle
Scan
First Element
Last Element
Aperture
Index Offset (mm)
TCG%
Focal Depth
Type of Weld
HAZ
Cap Width (mm)
1
90
2.25L64-A2
SA2-N55S
450
670
SECTORIAL
49
64
16
-16
75% 85%
50
Butt weld
25%
18
PHASED ARRAY ULTRASONIC TESTING RESULT Weld Scan Start-End Point (mm)
Line Number / Weld Joint 2GPI020-01-SP-02 Elbow to Elbow
0-400 400-800 800-1300
Weld Joint Parts
BW05A
Indica tion No. -
Location (mm) Start
End
-
-
Lengt h (mm) -
Depth (mm) Start
End
Height (mm)
-
-
-
Type of Indicatio n -
Location of Indication
Result
-
-
-
-
-
-
-
-
-
ACCEPTED ACCEPTED
-
-
-
-
-
-
-
-
-
ACCEPTED
-
-
-
-
-
-
-
-
-
Remarks
NOTE: LEGEND:
S: Surface Indication, SS: Subsurface Indication, LF: Lack of Fusion, IF: Interpass Fusion, CRK: Crack, COR: Corrosion, GEO: Geometrical Indication, ODS: Outer Surface, IDS: Inner Surface, FI: Fabrication Indication, II: In-service Indication
Data acquisitioned by:
Interpreted by:
Reviewed by:
RINKESH / EHSANULLAH
RINKESH / EHSANULLAH
ABDUL WAHEED
TCR Arabia PAUT Level II
TCR Arabia PAUT Level II
TCR ARABIA NDT MANAGER ASNT LEVEL III
8
TCR ARABIA COMPANY LIMITED PHASED ARRAY ULTRASONIC TESTING REPORT Client Project Location
ABENGOA (J3A) Independent Water Project JUBAIL
Test Procedure Technique Sheet No. Acceptance Standard
QCP/TCR/PAUT-004 REV.0 ASME B31.3
0-400
Date of Inspection Report No. Page No.
November 01,2022 RP-22-PAUT-261-TCR- ABENGOA 2 of 4
8
TCR ARABIA COMPANY LIMITED PHASED ARRAY ULTRASONIC TESTING REPORT Client Project Location
ABENGOA (J3A) Independent Water Project JUBAIL
Test Procedure Technique Sheet No. Acceptance Standard
400-800
QCP/TCR/PAUT-004 REV.0 ASME B31.3
Date of Inspection Report No. Page No.
November 01,2022 RP-22-PAUT-261-TCR- ABENGOA 3 of 4
8
TCR ARABIA COMPANY LIMITED PHASED ARRAY ULTRASONIC TESTING REPORT Client Project Location
ABENGOA (J3A) Independent Water Project JUBAIL
Test Procedure Technique Sheet No. Acceptance Standard
QCP/TCR/PAUT-004 REV.0 ASME B31.3
800-1300
Date of Inspection Report No. Page No.
November 01,2022 RP-22-PAUT-261-TCR- ABENGOA 4 of 4