29 0 505KB
ThyssenKrupp Aufzugswerke
Frequency-controlleddoordrives F9undF12
7
MA
PartNo.
6045
013
Type
TypeNo.
1 General DoordriveF9 ThedoordrivesF2/1andF5willbereplacedbythefrequency-controlleddoordriveF9.Thedoordrive F9hasamotorwithshrinked-onV-groovediskandacontroller.Motorandcontrolleraredesignedas monoblocunit. F2/1orF5doordrivesinstalledatexistinginstallations,areeasytoreplacebytheF9driveasthefitting dimensions2flangeandmountingholes3,theV-groovediskandtheelectricalconnectionsareidenticalin design.However,attentionmustbepaidtotheoutsidedimensionsduetotheintegratedcontroller.
MotorF9
ControllerF9
V-groovedisc
DoordriveF12 F12isanew,additionaldoordriveconsistingofthedoormotorF12withshrinked-ontoothbeltpulley discandacontrollerhousedinaseparatebox.
Toothbeltdisc
Preparedby:Pesch Issuingdepartment:VTS
DoormotorF12
Dateof issue:08.05
Changes: MA76045.013Newissue
ControllerF12
Page:
1
ThyssenKrupp Aufzugswerke
Frequency-controlleddoordrives F9undF12
7
MA
6045
013
Type
TypeNo.
PartNo.
2 Briefinstruction ThedoordrivesF9andF12areautomaticallyputintooperationbyselfteach-inroutine.Theteach-in operationmustbecarriedoutinalanding2carandlandingdoorsarecoupled3. Toputthedoorintooperation,the8pointsmentionedbelowmustbeobservedonly.Theparameters aresetbyselfteach-inroutine.Theymustnotbere-setthroughthediagnosticunit. Forspecialcasestherearetheopportunitytoputthedoorintooperationortochangeparametersbya Laptopwiththerequesteddiagnosisprogramsasfollows: Usablediagnosisprograms: -„WinDiag“2Diagnosticunit63ofTKAW -„E@syDrives“ofdrivemanufacturerSIEI-AREG 1Mountdoordrive6motor+control9,tightenbeltandmakeelectricalconnections; placethecableshieldinsidethecontrollerF126onlyappliestodoordriveF129 2
ChecktheHEXswitchS1andchange,ifnecessary Descriptionseetable„HEXswitchS1“,seechapter4.2
3
ChecktheHEXswitchS2andchange,ifnecessary Descriptionseetable„HEXswitchS2“,seechapter4.3.
4
CheckjumpersJ1,J2andJ3andplugorunplug,ifnecessary. DescriptionjumpersJ1andJ2orJ3seechapter4.4.
5
Thecarmustbemaintainedstationaryinthelanding6carandlandingdoorsarecoupled9
6
Pushthedoortohomeposition"CLOSED"byhand;camremainswidened!
7
PressbuttonT1atcontrollerforatleast5secondsuntilLEDH2willflash. teach-infunctionwillbestartedandcarriedoutautomatically. Fordetailsseedescriptionbelow.
8
Automaticstartingends,LEDH2andH3willlightcontinuously.
Detaileddescriptionseechapter4! 3 Operatingandindicatingelements CoverofcontrollerF12ordriveF9isopen. . ControllerF9 Preparedby:Pesch Issuingdepartment:VTS
ControllerF12 Operatingandindicating- elementsF9
Dateof issue:08.05
Operatingandindicating elementsF12
Changes: MA76045.013Newissue
Page:
2
ThyssenKrupp Aufzugswerke
Frequency-controlleddoordrives F9undF12
X6 InterfaceRS232 X226-poleRM3,813 1=+24V20V3 2=+0V224V3 3=TU 4=TO 5=TUL 6=Insp.release HEXswitchS1 CANON/OFF,HS;DL Seechapt.4.2 HEXswitchS2 Doormovement characteristics Seechapt.4.3 ButtonT1 Start-up JumperJ3 TerminatingresistorCAN Seechapt.4.4 LEDsH1,H2,H3,H4 Statusindicator Preparedby:Pesch Issuingdepartment:VTS
7
MA
PartNo.
6045
013
Type
TypeNo.
X723-poleRM7,53 1=N 2=PE 3=L
FuseF1 5AmT
JumperJ1,J2 24Vsupplyvoltage fromX2orX4 seechapt.4.4
X4 1=X5-1;X5-2 2=X5-1;X5-2 3=CAN-L 4=CAN-H 5=+24V2viaCAN3 6=0V2viaCAN3
X52CANbus3 1=X4-1;X4-2 2=X4-1;X4-2 3=CAN-L 4=CAN-H
RS485 Option
X324-poleRM3,813 1=TSU 2=TSO 3=output3 4=input5
Dateof issue:08.05
JumperJ4 Reset Seechapt.4.4
Changes: MA76045.013Newissue
Page:
3
ThyssenKrupp Aufzugswerke 4
Frequency-controlleddoordrives F9undF12
7
MA
PartNo.
6045
013
Type
TypeNo.
Descriptionofautomaticsetup 4.1 MountdoordriveF9ordoormotorF12withcontrollerF12. Observetomaketheelectricalconnections2temperatureprobe,pulseencoderandpowercable3 betweenthemotorandthecontrolleroftheF12doordrive,wherethemotorandcontrollerunitare separate.Takecarethattheshieldisapplied. Connectiontem peratureprobe DoordriveF12 Observethattheshield ispositionedproperly Connectionpulseencoder Connectionpowercable V-groovebeltwithdriveF92notavailablewithF123withuseofascrew,tightenthebelttensioningso thatthebeltbetweenthebeltpulleysislinkedbyapprox.8mmwithatestforceofapprox.80N2tension orpressure3! Note: Ifthewrongbelttensioningisusedthenthiscanleadtoahigherslippageordamagingofthe driveshaftorrollerbearings! Beltpulleyonlinkedshaft2door hanger3 V-groovebelt Beltpulleyon driveshaftF9 8mm
80N
Preparedby:Pesch Issuingdepartment:VTS
Dateof issue:08.05
Changes: MA76045.013Newissue
Page:
4
ThyssenKrupp Aufzugswerke
Frequency-controlleddoordrives F9undF12
7
MA
PartNo.
6045
013
Type
TypeNo.
4.2 AdjustmentHEX–ButtonS12CANon/off,HS,DL3check.PreadjustmentS1seetable.IfnecessaryadjustmentHEX–ButtonS1change. Mode CAN Automaticreversal S1 2150N–characteristics3 0 Diagnosticunit 1
ThyssenKrupp1
dF1E=1
inactive
Default
2
ThyssenKrupp2
dF1E=2
inactive
3
ThyssenKruppUSA1
dF1E=1
Active
4
ThyssenKruppUSA2
dF1E=2
Active
5
LiftEquip1
dF1E=0
inactive
6
LiftEquip2
dF1E=0
active
DF1E=0…doornotcontrolledviaCAN DF1E=1…CANmainentranceside2HS3 DF1E=2…CANfrontandrearentranceside2DL3
4.3 AdjustmentHEX–buttonS22door-drivingcycle3check.PreadjustmentS2accordingtodrivetypesee table.IfnecessaryadjustmentHEX–ButtonS2change. max. max. max. ratio S2 Mode energy speedopening speedclosing pulses/cm operation operation 0 Diagnostic unit 1 Slow 7J 0,3m/s 0,25m/s i=130 F9withK8 2
normal
10J
0,45m/s
0,3m/s
i=130
3
Fast
20J
0,65m/s
0,4m/s
i=130
4
Slow
7J
0,3m/s
0,25m/s
i=64
F9withK8 DEFAULT F9withK8
F12with K12 5 normal 10J 0,45m/s 0,3m/s i=64 F12with K12 DEFAULT 6 fast 20J 0,6m/s 0,35m/s i=64 F12with K12 Thedoormovementtimesaredeterminedbymax.energyormax.speeds,accelerationsand decelerations.
Preparedby:Pesch Issuingdepartment:VTS
Dateof issue:08.05
Changes: MA76045.013Newissue
Page:
5
ThyssenKrupp Aufzugswerke
Frequency-controlleddoordrives F9undF12
7
MA
PartNo.
6045
013
Type
TypeNo.
4.4 ControlofthejumpersJ1,J2andJ3.Ifnecessary,plugjumperonnecessaryarea. JumperJ1andJ2 JumpersJ1andJ2areintendedforusewithdoordrivefedwith24Vvoltage. Position1-2supplyfromconnectorX22standard3.DEFAULT Position2-3supplyfromconnectorX42togetherwithtransmissionofCANsignals3. JumperJ3 JumperpluggedinjumperisterminatingresistorofCANline2120Ohm3. JumperunpluggedendofCANlinesomewhereelse2e.g.LMS13. terminatingresistornotsethere.DEFAULT JumperJ4 JumperpluggedinRESETiscarriedout JumperunpluggedDEFAULT
JumperJ1
Preparedby:Pesch Issuingdepartment:VTS
JumperJ2
Jumper32unplugged3
Dateof issue:08.05
Changes: MA76045.013Newissue
Page:
6
ThyssenKrupp Aufzugswerke
Frequency-controlleddoordrives F9undF12
7
MA
PartNo.
6045
013
Type
TypeNo.
4.5 Automaticstartingistobecarriedoutwiththecarandlandingdoorscoupled.Thecarmustbekept stationaryinalandinghere. 4.6 Pushthecoupleddoorbyhandintothestartingposition“closed“,thecamremainswidened. 4.7 KeepbuttonT1presseddownonthecontrollerF9orF12.TheLEDH2willstartblinkingafterthe buttonT1hasbeenpressedfor5sec.Ifthebuttonisnowreleased,theautomaticstartupwill begin. TheLEDH2blinksduringtheentireautomaticprocedure.Ifthebuttonisnotreleasedinthenext5sec afterH2hasstartedblinking,thentheautomaticstartupwillnotbeimplementedandtheLEDH2willgo off.Noparameterwillbechanged. Thetimeofoperationshallpreventthattheautomaticteach-inoperationwillbe activatedunintentionallywhilethecablesetc.arebeingpluggedin.Thismeansthatautomaticstartup isactivatedbyreleasingthebuttonwiththeLEDH2flashing.Thedoordriveautomaticallycarriedout theteach-inphasesincludingresetwithouttheneedofanyfurtheractivities2duration:approx.1min3! Thestatedparametersaredeterminedinthecourseofdifferentdooroperationsbyaspecialalgorithm havingafuzzycontrol.ThetwoSMDLEDsH1andH3indicatethethreephasesoftheteach-inoperation. Teach-inphase1Determinedoorwidth H1blinks;H2flashes;H3off 2doorisopenedandclosedatlowspeed3 Teach-inphase2Teach-inoperatingforce H1off; H2flashes; H3blinks 2Doorisopenandclosedatlowspeed3 Teach-inphase3Determinedoormass H1,H3blinkalternately 2Dooracceleratesatmax.speed, H2flashes; duringDOOROPENoperation3 Finish Checkparametersand H1;H2;H3ONfor5sec. save Reset Driveisreadyforoperation 4.8 AftersuccessfullycompletedautomaticstartuptheLEDsH2andH3willbecontinuouslylighted.
Preparedby:Pesch Issuingdepartment:VTS
Dateof issue:08.05
Changes: MA76045.013Newissue
Page:
7
ThyssenKrupp Aufzugswerke 5
Frequency-controlleddoordrives F9undF12
7
MA
PartNo.
6045
013
Type
TypeNo.
Additionalnotesonautomaticstart-up Thespeedfordoor-closeoperationissetinsuchawaythattheaveragekineticenergyismaintained