User Guide

Elevator Destination Group Control System User Guide

A00 Data code 19010967



Preface

Preface

Thank you for purchasing the integrated elevator destination group control system developed by Suzhou Monarch.

This product can work with the NICE series integrated elevator controllers to implement intelligent dispatch of elevator groups in buildings. The guide provides users with instructions on model selection, installation, parameter setting, on-site commissioning, and maintenance. In order to correctly use this product, read this guide carefully before use, and keep the guide carefully for future reference. Notes

◆◆ For illustration purpose, the drawings in this guide are sometimes shown without covers or protective guards. Remember to install the covers or protective guards as specified before using the product, and perform operations in accordance with the instructions. ◆◆ The drawings in this guide are for illustration only. Actual products may vary.

◆◆ The instructions are subject to change, without notice, due to product upgrade, specification modification as well as efforts to increase the accuracy and convenience of the user guide.

◆◆ Contact the regional agents or customer service center of Inovance if you have problems during use. ◆◆ E-mail: [email protected].

-1-

Contents

Contents

Preface..................................................................................................................................... 1 Introduction............................................................................................................................. 4 Revision History...................................................................................................................... 7 Safety Instructions.................................................................................................................. 8 Safety Precautions.............................................................................................................8 Safety Levels and Definitions............................................................................................8 Safety Instructions.............................................................................................................8 Safety Signs.......................................................................................................................12

Chapter 1 Product Information............................................................................................ 13 1.1 System Components................................................................................................ 13 1.2 System Principle....................................................................................................... 14 1.3 Model Number.......................................................................................................... 15 1.3.1 Group Control Board...............................................................................................15 1.3.2 Floor Selector...........................................................................................................15 1.3.3 Touchscreen-Type Floor Selector Bracket...........................................................15 1.3.4 IC Card Options........................................................................................................15 1.3.5 Car Display................................................................................................................16

1.4 Technical Data........................................................................................................... 16 1.4.1 Group Control Board...............................................................................................16 1.4.2 Car Display................................................................................................................16

1.4.3 Floor Selector...........................................................................................................17

Chapter 2 Mechanical and Electrical Installation............................................................... 18 2.1 Installation Environment Requirements................................................................. 18 2.2 Group Control Board................................................................................................ 18

2.2.1 Dimensions...............................................................................................................18

2.2.2 Terminal Description...............................................................................................19

2.3 Floor Selector............................................................................................................ 21 2.3.1 Function Description..............................................................................................21 2.3.2 Installing the 10.4-Inch Wall-Mounted Touchscreen...........................................21

2.3.3 Installing the 10.4-Inch Vertical Touchscreen......................................................23 2.3.4 Installing the 15-Inch Wall-Mounted Touchscreen..............................................25 2.3.5 Installing the 15-Inch Vertical Touchscreen.........................................................27 2.3.6 Installing the Keypad-Type Floor Selector...........................................................28

2.3.7 Terminal Description...............................................................................................30

2.4 Car Display ............................................................................................................... 31

-2-

2.4.1 Dimensions...............................................................................................................31



Contents

2.4.2 Terminal Description...............................................................................................31 2.4.3 Function Description...............................................................................................31

2.5 Wiring of the Elevator Destination Group Control System.................................... 33

Chapter 3 System Commissioning....................................................................................... 34 3.1 LED Operating Panel................................................................................................. 34 3.2 Operations of the MCTC-DDS-T Series Floor Selector............................................ 37 3.2.1 Interface Description..............................................................................................37 3.2.2 Key Description........................................................................................................37 3.2.3 Parameter Settings.................................................................................................37 3.2.4 Elevator Calls...........................................................................................................38

3.3 Operations of the MCTC-DDS-K1 Series Floor Selector......................................... 39 3.3.1 Introduction to the Floor Selector ........................................................................39

3.3.2 Description of Keys..................................................................................................40 3.3.3 Parameter Settings.................................................................................................41 3.3.4 Elevator Calls...........................................................................................................42 3.3.5 Selecting a Destination Floor by the Disabled.....................................................43

3.4 Quick System Commissioning................................................................................. 44

Chapter 4 Parameters........................................................................................................... 46 4.1 Parameters of the Group Control Board................................................................. 46 4.2 Parameters of the Floor Selector ............................................................................ 60

Chapter 5 Parameter Description........................................................................................ 64 5.1 Description of Group Control Board Parameters................................................... 64 Group F0: Basic Parameters........................................................................................... 64

Group F1: Terminal Parameters......................................................................................67

Group F2: Zoning Parameters.........................................................................................68

Group F3: Traffic Time Setting Parameters...................................................................70 Group FU: System Monitoring Parameters....................................................................76

Group FP: User Parameters.............................................................................................89

5.2 Description of Floor Selector Parameters............................................................... 89

Group F0: Display Parameters.........................................................................................89 Group F1: Basic Parameters............................................................................................90

Group F2: Floor Display Parameters...............................................................................92

Group FP: Protection Parameters...................................................................................93

Chapter 6 Maintenance......................................................................................................... 95 6.1 Daily Maintenance.................................................................................................... 95 6.2 Periodic Inspection................................................................................................... 95 6.3 Storage...................................................................................................................... 95

Warranty Agreement............................................................................................................. 96

-3-

Introduction

1) Product introduction

Introduction

The elevator destination group control system with an integration of the intelligent chip and intelligent group control algorithm works with the NICE series integrated elevator controller to implement intelligent dispatch of elevator groups in buildings. 2) Features

■■ Group control for all destination floors

A destination floor selector is installed on each floor. ■■ Group control of multiple elevators

Group control can be implemented for up to eight elevators.

■■ Highly-efficient and safe group control system developed based on the CAN bus. The group control system is safe and stable, and can respond to calls more quickly. ■■ Reduced elevator system cost of a building

Zoned elevator control effectively reduces the waiting and travel time of passengers as well as the total number of elevators required in a building. ■■ Energy-saving

Highly-efficient elevator dispatch reduces the number of operation times of elevators in a building, thereby saving electric energy. ■■ Flexible

This system is equipped with multiple transportation modes, and with the functions of traffic mode time setting and intelligent traffic mode learning. These flexible configurations can meet the requirements of various application scenarios in buildings. ■■ User-friendly

This system is equipped with real-time guidance function. The floor selector can quickly display the ID and direction of the assigned elevator upon receiving a valid elevator call. ■■ Intelligent

This system is equipped with automatic traffic mode learning function. Based on the historical traffic data, the system forecasts the traffic mode appropriate for the following moment. ■■ Performance evaluation

The performance evaluation function allows you to accurately evaluate the performance of the group control system.

-4-



3) Function list Function

Dispersed elevator waiting

VIP function Operation limit with backup power supply

Introduction

Description

When the group control system detects that the waiting time of an elevator has reached the specified value, it instructs the elevator to return to the main floor. Elevator waiting modes: ◆◆ Main floor elevator waiting: Users can specify three main floors and set the number of waiting elevators for each of the floors. ◆◆ Zoned elevator waiting: If users set the zones by themselves, the system instructs the elevators that have reached the maximum idle time to wait in these zones. Otherwise, the system automatically calculates the number and length of zones based on the number of elevators and the height of a building, and instructs the elevators that have reached the maximum idle time to wait in these zones.

If a call from a VIP floor is received and the VIP switch is active, the VIP input is valid and the related elevator runs in VIP mode. The group control system does not send other calls to the elevator, ensuring that the elevator serves only for VIP personnel. When the main power supply of a building fails and the system is powered by the backup power supply, the number of operational elevators is limited. Users can set the number of operational elevators by themselves.

Traffic mode time setting

The traffic mode within a specified period of time can be set in two methods: ◆◆ Set by users.

User-defined traffic mode

Users can set the traffic mode for each of the 10 periods per day. For a week, they can set the mode for 70 periods in total.

Automatic traffic mode learning

◆◆ Set through automatic traffic mode learning.

The system is equipped with automatic traffic mode learning. Based on the parameters of each period in each day of each week stored in SD card as well as the historical data, the system forecasts the traffic mode for the next moment. The large amount of historical data makes the forecast more intelligent and accurate.

-5-

Introduction

Function

Description

Energy-saving mode Up peak mode

Multiple traffic modes

Down peak mode Normal traffic mode Sudden peak hour mode

After the system enters the up peak mode, if an elevator has no call to respond, it returns to the peak service floor to ease the up traffic jam on this floor. This mode is available if zones are defined, so as to better ease the down traffic jam. When an elevator is idle, it returns to the terminal floor that is away from the down peak floor in that zone. If zones are not defined, the software automatically sets the zones.

When the traffic is normal and elevator calls do not differ greatly across floors, the system works in this mode.

You can set the floors for the sudden peak hour service and the number of elevators for these floors. If more than three calls are received from a peak floor and no elevator is available on the floor, the system sends the preset number of elevators to that floor to better provide services for the floor.

Disability service

This function enables the system to assign an accessible elevator when there is a call. In addition, a voice prompt is given when keys are pressed.

Group control output

Parameters can be used to view some indicators of the group control system in a certain period of time, including the average waiting time, average travel time, full-load rate, and long-time waiting rate.

Real-time guidance

Zoned service Grouping

-6-

When the traffic is light, the system enters the energysaving mode. Based on the group control rule, fewer elevators are running to save energy within the allowable range of waiting time.

After a call from a floor is received, the floor selector displays the ID of the assigned elevator in real time.

Service zones are defined for elevators based on the building height and number of floors. Zones can be defined automatically or manually.

When multiple passengers need to take elevators at the same time to the same floor, enter the number of passengers and the destination floor. The system then automatically sets the number of elevators that provide services for the passengers.



Date

April 2019

Revision History

Version A00

First release.

Revision History

Change Description

-7-

Safety Instructions

Safety Precautions

Safety Instructions

1) Before installing, using, and maintaining this equipment, read the safety information and precautions thoroughly, and comply with them during operations. 2) To ensure the safety of humans and equipment, follow the signs on the equipment and all the safety instructions in this user guide.

3) "CAUTION", "WARNING", and "DANGER" items in the manual do not indicate all safety precautions that need to be followed; instead, they just supplement the safety precautions. 4) Use this equipment according to the designated environment requirements. Damage caused by improper usage is not covered by warranty.

5) Inovance shall take no responsibility for any personal injuries or property damage caused by improper usage.

Safety Levels and Definitions DANGER

indicates that failure to comply with the notice will result in severe personal injuries or even death.

indicates that failure to comply with the notice may result in severe

WARNING personal injuries or even death.

indicates that failure to comply with the notice may result in minor

CAUTION personal injuries or damage to the equipment.

Safety Instructions

Unpacking

CAUTION

◆◆ Check whether the packing is intact and whether there is damage, water seepage, damp, and deformation. ◆◆ Unpack the package by following the package sequence. Do not hit the package with force. ◆◆ Check whether there are damage, rust, or injuries on the surface of the equipment or equipment accessories. ◆◆ Check whether the number of packing materials is consistent with the packing list.

WARNING

◆◆ Do not install the equipment if you find damage, rust, or indications of use on the equipment or accessories. ◆◆ Do not install the equipment if you find water seepage, component missing or damage upon unpacking. ◆◆ Do not install the equipment if you find the packing list does not conform to the equipment you received.

-8-



Safety Instructions

Storage and Transportation

CAUTION

◆◆ Store and transport this equipment based on the storage and transportation requirements for humidity and temperature. ◆◆ Avoid transporting the equipment in environments such as water splashing, rain, direct sunlight, strong electric field, strong magnetic field, and strong vibration. ◆◆ Avoid storing this equipment for more than three months. Long-term storage requires stricter protection and necessary inspections. ◆◆ Pack the equipment strictly before transportation. Use a sealed box for long-distance transportation. ◆◆ Never transport this equipment with other equipment or materials that may harm or have negative impacts on this equipment.

WARNING

◆◆ Use professional loading and unloading equipment to carry large-scale or heavy equipment. ◆◆ When carrying this equipment with bare hands, hold the equipment casing firmly with care to prevent parts falling. Failure to comply may result in personal injuries. ◆◆ Handle the equipment with care during transportation and mind your step to prevent personal injuries or equipment damage. ◆◆ Never stand or stay below the equipment when the equipment is lifted by hoisting equipment.

Installation

WARNING

◆◆ Thoroughly read the safety instructions and user guide before installation. ◆◆ Do not modify this equipment. ◆◆ Do not rotate the equipment components or loosen fixed bolts (especially those marked in red) on equipment components. ◆◆ Do not install this equipment in places with strong electric or magnetic fields. ◆◆ When this equipment is installed in a cabinet or final equipment, protection measures such as a fireproof enclosure, electrical enclosure, or mechanical enclosure must be provided. The IP rating must meet IEC standards and local laws and regulations.

DANGER

◆◆ Equipment installation, wiring, maintenance, inspection, or parts replacement must be performed by only professionals. ◆◆ Installation, wiring, maintenance, inspection, or parts replacement must be performed by only experienced personnel who have been trained with necessary electrical information. ◆◆ Installation personnel must be familiar with equipment installation requirements and relevant technical materials. ◆◆ Before installing equipment with strong electromagnetic interference, such as a transformer, install an electromagnetic shielding device for this equipment to prevent malfunctions.

-9-

Safety Instructions

Wiring

DANGER

◆◆ Equipment installation, wiring, maintenance, inspection, or parts replacement must be performed by only professionals. ◆◆ Never perform wiring at power-on. Failure to comply will result in an electric shock. ◆◆ Before wiring, cut off all equipment power supplies. Wait at least 10 minutes before further operations because residual voltage exists after power-off. ◆◆ Make sure that the equipment is well grounded. Failure to comply will result in an electric shock. ◆◆ During wiring, follow the proper electrostatic discharge (ESD) procedures, and wear an antistatic wrist strap. Failure to comply will result in damage to internal equipment circuits.

WARNING

◆◆ Never connect the power cable to output terminals of the equipment. Failure to comply may cause equipment damage or even a fire. ◆◆ When connecting a drive with the motor, make sure that the phase sequences of the drive and motor terminals are consistent to prevent reverse motor rotation. ◆◆ Wiring cables must meet diameter and shielding requirements. The shielding layer of the shielded cable must be reliably grounded at one end. ◆◆ After wiring, make sure that no screws are fallen and cables are exposed in the equipment.

Power-on

DANGER

◆◆ Before power-on, make sure that the equipment is installed properly with reliable wiring and the motor can be restarted. ◆◆ Before power-on, make sure that the power supply meets equipment requirements to prevent equipment damage or even a fire. ◆◆ At power-on, unexpected operations may be triggered on the equipment. Therefore, stay away from the equipment. ◆◆ After power-on, do not open the cabinet door and protective cover of the equipment. Failure to comply will result in an electric shock. ◆◆ Do not touch any wiring terminals at power-on. Failure to comply will result in an electric shock. ◆◆ Do not remove any part of the equipment at power-on. Failure to comply will result in an electric shock.

- 10 -



Safety Instructions

Operation

DANGER

◆◆ Do not touch any wiring terminals during operation. Failure to comply will result in an electric shock. ◆◆ Do not remove any part of the equipment during operation. Failure to comply will result in an electric shock. ◆◆ Do not touch the equipment shell, fan, or resistor for temperature detection. Failure to comply will result in heat injuries. ◆◆ Signal detection must be performed by only professionals during operation. Failure to comply will result in personal injuries or equipment damage.

WARNING

◆◆ Prevent metal or other objects from falling into the device during operation. Failure to comply may result in equipment damage. ◆◆ Do not start or stop the equipment using the contactor. Failure to comply may result in equipment damage.

Maintenance

DANGER

◆◆ Equipment installation, wiring, maintenance, inspection, or parts replacement must be performed by only professionals. ◆◆ Do not maintain the equipment at power-on. Failure to comply will result in an electric shock. ◆◆ Before maintenance, cut off all equipment power supplies and wait at least 10 minutes.

WARNING

◆◆ Perform daily and periodic inspection and maintenance for the equipment according to maintenance requirements and keep a maintenance record.

Repair

DANGER

◆◆ Equipment installation, wiring, maintenance, inspection, or parts replacement must be performed by only professionals. ◆◆ Do not repair the equipment at power-on. Failure to comply will result in an electric shock. ◆◆ Before inspection and repair, cut off all equipment power supplies and wait at least 10 minutes.

- 11 -

Safety Instructions

WARNING

◆◆ Require for repair services according to the product warranty agreement. ◆◆ When the equipment is faulty or damaged, require professionals to perform troubleshooting and repair by following repair instructions and keep a repair record. ◆◆ Replace quick-wear parts of the equipment according to the replacement guide. ◆◆ Do not operate damaged equipment. Failure to comply may result in worse damage. ◆◆ After the equipment is replaced, perform wiring inspection and parameter settings again.

Disposal

WARNING

◆◆ Dispose of retired equipment by following local regulations or standards. Failure to comply may result in property damage, personal injuries, or even death. ◆◆ Recycle retired equipment by following industry waste disposal standards to avoid environmental pollution.

Safety Signs

For safe equipment operation and maintenance, comply with safety signs on the equipment, and do not damage or remove the safety labels. The following table describes the safety signs. Safety Sign

- 12 -

Description

◆◆ Read the user guide before installation and operation. Failure to comply will result in an electric shock. ◆◆ Do not remove the cover at power-on or within 10 minutes after power-off. ◆◆ Before maintenance, inspection, and wiring, cut off input and output power, and wait at least 10 minutes until the power indicator is off.



Chapter 1 Product Information

Chapter 1 Product Information 1.1 System Components

The destination group control system groups multiple elevators (up to eight elevators). After a passenger enters the destination floor number using the floor selector, the system assigns one of the elevators to the passenger based on the current operating status of the elevators. The system is composed of a group control board (GCB), floor selectors, and a multielevator control system. The following figure shows the system components. 485 Independent power supply

Power port

CAN1 CANbus

2 3

3

1

2

3

7

8

9

4

5 0

3

6

?

CANbus 1 4 7

2

3

8

9

5 0

1

2

7

8

4

?

MODbus

CTB

3

5 0

...

6 9 ?

-

CCB

CAN8

...

… Arrival indicator for floor 2 Arrival indicator for floor 1

4

232

CAN...

CAN2

6 -

IO

1 MCTC-GCB-B1

Arrival indicator for floor N

-

... 3

Elevator A

RJ45

RUN

LOCAL/REMOT

Hz

RPM

A

PRG

FED/ REV

%

TUNE/TC

V

ENTER

QUICK

RUN

MF.K

STOP RES

Elevator H

CANbus

3

3

1 4 7

2

6 9 -

?

CANbus 1 4 7

2

3

8

9

5 0

1 4 7

?

2

-

MODbus

CTB

3

5

6

8

0



6

... 3

Arrival indicator for floor N

3

5 8

0

9 ?

-

CCB

Arrival indicator for floor 2 Arrival indicator for floor 1

Figure 1-1 System components

◆◆ The preceding figure shows a group control example of eight elevators (elevators A, B, C, D, E, F, G, and H).

NOTE

SN

Table 1-1 Name and models of system components

Name



GCB



Floor selector

Model

MCTC-GCB-B1 MCTC-DDS-T1 MCTD-DDS-T2 MCTC-DDS-K1

Standard

Description

Standard (select at least one from the three models)

- 13 -

Chapter 1 Product Information

SN



Name

Car display Integrated elevator controller

Elevator Car top control board (CTB) system

Car call board (CCB) Hall arrival indicator



LED operating panel

1.2 System Principle

Model

MCTC-HCB-T3-DDS NICE series MCTC-CTB MCTC-CCB-A MCTC-HCB-B and related options MDKE

Description

Standard (dedicated to destination group control) For details, see the user guides of NICE series integrated elevator controllers. Optional (See the user guides of NICE series integrated elevator controllers) Optional (For details, consult Inovance).

Optional External LED operating panel, connected to RJ45 port.

The GCB is the core computing unit. The floor selector is the collection unit of registered destination floor information. The integrated elevator controller is the transportation control unit that implements all control and operation functions of an elevator. The car display is the unit that displays the next stop floor, current floor, and elevator running direction. The GCB communicates with the floor selector through the CAN bus to collect passengers’ calls entered using the floor selector. In addition, the GCB exchanges data with the NICE series integrated elevator controllers through the CAN bus. The GCB performs computation and comparison to identify the optimum elevator for a passenger's call. Then, it drives the elevator to take the passenger and sends the ID of the elevator to corresponding floor selector accordingly. The floor selector displays the ID of the elevator to take and makes a corresponding voice prompt.

After receiving the elevator dispatch command sent by the GCB, the integrated elevator controller immediately performs the operation logic control and drives an elevator to take the passenger. After the elevator arrives at the floor where the passenger waits and the passenger enters the car, the controller records the destination floor number automatically and takes the passenger to the destination floor. In addition, the next stop floor, current floor, and elevator running direction are displayed on the car display board. Based on this logic, the destination group control system controls the coordinated operation of each component to complete the transportation task.

- 14 -



Chapter 1 Product Information

1.3 Model Number

1.3.1 Group Control Board Mark

MCTC – GCB – B1

Product Series

Mark

Option for integrated elevator controllers

MCTC Mark

Destination Floor

Destination floors of eight elevators

B1

Type

GCB

Group control board

1.3.2 Floor Selector Mark

Product Series

MCTC

Option for integrated elevator controllers

Mark

Type

DDS

Figure 1-2 Model number of the GCB

MCTC - DDS -T1-IC

Mark

IC Card Function

IC

Yes

Blank

No

Mark

Floor selector

Size

T1

10.4-inch touchscreen

T2

15-inch touchscreen

K1

4.3-inch keypad

Figure 1-3 Model number of the floor selector

1.3.3 Touchscreen-Type Floor Selector Bracket Mark

MCTC Mark DDS

Mark T1 T2

Product Series

Option for integrated elevator controllers Floor selector

MCTC Mark DCS

Mark

IC Card Function

Blank

No

IC

Type

Mark B1

Size of Compatible Touchscreen

B2

10.4-inch

Yes

Mounting Method

Vertical bracket

Wall-mounted bracket

15-inch

Figure 1-4 Model number of the touchscreen-type floor selector bracket

1.3.4 IC Card Options Mark

MCTC - DDS -T1- B1-IC

Product Series

MCTC - DCB -IC-A

Option for integrated elevator controllers Type

IC card options for elevator destination group control system

Figure 1-5 Model number of IC card options

Mark

Option

A

Controller

C

Card

W

Card writer

- 15 -

Chapter 1 Product Information

1.3.5 Car Display Mark

MCTC Mark

HCB-T3

MCTC – HCB - T3 - DDS

Product Series

DDS

Type

Standard display board

1.4 Technical Data

Item

Table 1-2 System technical data

Input voltage

Communication mode

Basic Number of elevators supported performance parameters Number of floor selectors supported

1.4.2 Car Display

Communication distance

Specifications

24 VDC (-10% to +10%) CAN communication

Maximum: eight elevators

Each CAN communication port supports 56 floor selectors. The maximum total number of floor selectors is 56 × 8. Above 1000 m

Table 1-3 Technical data of the MCTC-HCB-T3-DDS car display

Item

Specifications

Power supply

24 VDC (-10% to +10%)

Physical dimensions

250 x 194 x 32 (unit: mm)

Display mode

Valid display range Basic performance parameters

Applicable System

Destination group control system

Figure 1-6 Model number of the car display

1.4.1 Group Control Board

Resolution

Communication mode Power consumption

Operating ambient temperature Operating ambient humidity Function

- 16 -

Mark

Option for integrated elevator controllers

True-color display

197 x 148 (unit: mm) 1024 x 768

485 communication ≤6W

-20℃ to +70℃

Less than 95%RH, non-condensing

Horizontal display, elevator running status display, and destination floor number display



Chapter 1 Product Information

1.4.3 Floor Selector

The floor selector is a key interface for information exchange between users and the control system. It can receive user calls at a hall. The following table shows the main technical data. Table 1-4 Parameters of the floor selector

Model

MCTC-DDS-T1

MCTC-DDS-T2

MCTC-DDS-K1

Size of the display screen

10.4-inch

15-inch

4.3-inch

Equipment power consumption

≤ 7.5 W

≤ 15 W

≤ 12 W

Power supply voltage Valid display range (W x H) Type of LCD

Display resolution (W x H)

Horizontal viewing angle

18–36 VDC

18–36 VDC

159.5 mm × 212.5 mm 305 mm × 229 mm

95 mm × 54 mm

800 × 600 dot

480 × 272 dot

a-Si, LED backlit

a-Si, LED backlit

-70º to +70º

-70º to +70º

-70º to +70º

-10℃ to +60℃

-10℃ to +60℃

-20℃ to 70℃

Vertical viewing angle -70º to +40º Operating ambient temperature Operating ambient humidity

18–36 VDC

10%RH to 90%RH, non-condensing

1024 × 768 dot

-70º to +70º

10%RH to 90%RH, non-condensing

TFT VGA color display

-70º to +40º

10%RH to 90%RH, non-condensing

The models of the touchscreen-type floor selector bracket are shown in the following table. Model

MCTC-DDS-T1-B1 MCTC-DDS-T1-B2 MCTC-DDS-T2-B1 MCTC-DDS-T2-B2

Table 1-5 Parameters of the floor selector bracket

Description

Max. Dimensions (unit: mm)

10.4-inch touchscreen-type floor selector (vertical)

260.5 × 239 × 1020.6

15-inch touchscreen-type floor selector (vertical)

343.4 × 230.28 × 1075.26

10.4-inch touchscreen-type floor selector (wall-mounted) 15-inch touchscreen-type floor selector (wall-mounted)

260.5 × 171.32 × 254.67

343.4 × 224.52 × 436.55

- 17 -

Chapter 2 Mechanical and Electrical Installation

Chapter 2 Mechanical and Electrical Installation 2.1 Installation Environment Requirements ■■ Ambient temperature: -20℃ to +70℃

■■ Install it in a place free from vibration.

■■ Install it in a place free from direct sunlight, high humidity and condensation. ■■ Install it in a place free from corrosive, flammable, or explosive gas.

■■ Install it in a place free from oil dirt, heavy dust and heavy metal powder.

High temperature and humidity Operating temperature: -20°C to +70°C

Flammable, explosive, or corrosive gas

2.2 Group Control Board

Strong vibration

Combustible material

Do not install the product on the surface of a flammable object.

Sunlight

Oil dirt, heavy dust or heavy metal powder

2.2.1 Dimensions

The MCTC-GCB-B1 is the core component of the group control system. It has eight digital input (DI) terminals and four digital output (DO) terminals. The following figure shows the appearance and dimensions of the MCTC-GCB-B1.

- 18 -



Chapter 2 Mechanical and Electrical Installation CN15

160

CN14

5

9

4

8

3

7

2

J9

6

1

CN1

MCTC-GCB-BI

148

D78 D71 D65 D60 D55 D51 D46 D41 D94 D85 D86 D81 D80 D79

4-M4

CN2

D17 D15 D13 D12

CN5

D8 D7 D6 D5 D4 D3 D2

CN3

CN4

CN6

CN7

CN8

CN9

CN10

CN11

D1

CN12 CN13

268 280

Figure 2-1 Appearance and dimensions of the MCTC-GCB-B1 (unit: mm)

2.2.2 Terminal Description

24V/COM

Isolated CAN communication power supply

J9 CN1

24V/GND

485+/485DB9 port

RJ45 port

1234

Isolated CAN communication port

Isolated 485 communication power supply

1234

Isolated 485 communication port

232 host controller communication port

GND

24 V power input of the GCB

Remarks +24V

24V/GND

CN3-CN4 CN6-CN13 CANH/CANL CN14

Functions Description

+24V CANH CANL COM

CN15

Mark

+24V 485+ 458GND

Type

Table 2-1 Description of GCB terminals

1234 5

2

3

4 9

8

7

1 6

Connected to the LED operating panel to set and view the parameters of the GCB.

- 19 -

Chapter 2 Mechanical and Electrical Installation

Type

CN5

Mark

X1-X8/GND

Functions Description

Used for DI: 1. Photocoupler input 2. Input impedance: 4.7 kΩ 3. Voltage range upon level input: 10–30 VDC 4. Max. input current: 5 mA 4.7K

GND

(DI terminals) CN2

Y1-Y4, M1, M2

Relay output Y1 to Y4 Normally open (NO) contact output of the relay: 5 A, 250 VAC/28 VDC

D1 to D8

DI indicators

These indicators becomes ON (green) when the external input signal is active.

Relay output D12 to D17 indicators

D78, D71, D65, D60, D55, D51, D46, and D41

D85, D86, D81 and D80

These indicators indicate the CAN communication status of elevators 1 to 8. Flashing: Indicating that the elevator is in the automatic running state, with normal CAN CAN communication. communication Steady ON: Indicating that the elevator is not indicators in the automatic running state, but the CAN communication is normal. Steady OFF: Indicating that CAN communication of the elevator is interrupted. Reserved

-

D79

24 V power indicator

This indicator becomes ON after the GCB is powered up.

D94

Fault indicator

NOTE

- 20 -

These indicators becomes ON (green) when there is a system output.

This indicator becomes ON if an elevator runs out of the group control or there is a communication error.

Remarks

GND

10

9 8 7 6 5 4 3 2 1

GND

6 5 4 3 2 1

M2 Y4 M1 Y3 Y2 Y1

X8 X7 X6 X5 X4 X3 X2 X1

D1 D2 D3 D4 D5 D6 D7 D8

D12 D13 D15 D17

D78 D71 D65 D60

D55 D51 D46 D41

D79

D94

◆◆ To prevent external communication interference, use the shielded twisted pair (STP) as communication cables and avoid laying them in parallel. ◆◆ The GCB must be powered by an independent 24 V power supply, and cannot share the 24 V power supply with the elevator system.



Chapter 2 Mechanical and Electrical Installation

2.3 Floor Selector

2.3.1 Function Description Function

Table 2-2 Function description of the floor selector

Parameter setting

Disability function

Description

It can be used to set the floor selector parameters. It collects the calls from disabled passengers.

Destination floor information It collects the destination floor information entered by collection passengers using buttons. LCD display

It displays the entered destination floor.

IC card function

It supports the call registration by swiping IC card.

Buzzer prompt

Elevator indication

Voice announcement

It tweets when keys are pressed.

It notifies passengers of the ID of the elevator to wait.

It supports the voice announcement function (applicable only to the touchscreen-type floor selectors).

Floor selection touch button: Passengers can select their destination floor by touching the floor buttons, and then the selected buttons light up.

Available elevator indication: After a passenger selects the destination floor, the floor selector display the ID of the assigned elevator for the passenger to take, reducing waiting time. Soft and clear female voice announcement: After a passenger selects the destination floor, a soft and clear female voice prompts the passenger to take the available elevator, enhancing the riding comfort. Date and week displays: The current date and week are displayed in real time, and you can calibrate them using the touchscreen. Customization: After entering the correct password, the administrator can set various floor selector parameters, such as the floor selector display and function parameters, floor display parameters, and system parameters.

2.3.2 Installing the 10.4-Inch Wall-Mounted Touchscreen 1) Product appearance

Notes: 1) The floor selector consists of a touchscreen (MCTC-DDS-T1-IC) and a wall-mounted bracket (MCTC-DDS-T2-B2-IC). 2) If no IC card reader is equipped, install a black acrylic plate in the position reserved for the card reader. 3) Errors in the physical dimensions or differences in the surface textures of different batches of products may exist. The physical dimensions and surface textures are subject to the actual product.

- 21 -

Chapter 2 Mechanical and Electrical Installation

2) Dimensions

260.5

167.91

43

20

Flange Self-clinching nuts

Round head screws

2 9.

200

Side view

260.5 212.5

160

199.5

130 R5

60

40

5

130

112.4 72.8

.5

88.2

Ø5

77

54.5

Touchscreen dimensions

Dimensions of a black acrylic plate

Dimensions of an IC card

3) Installation procedure

4-Φ8

50

130

50

35

40

40 130

Height above ground: 807 mm

- 22 -

0

72.5

R1

Rear view

54.8

65

20

90

61

57

Ø

Ø1 0

93 .2

40 º 183.92

R1

72.6

185

Front view

Four M3x8 countersunk head screws and four M3 hexagon nuts with flange

0

14 5º

251.1

37.75 56.25

14

Hole dimensions



Step

Chapter 2 Mechanical and Electrical Installation

Step 1: Punch holes in the wall, and install the horn. Options: four M3x8 countersunk head screws and four M3 hexagon nuts with flange



Diagram

Step 2: Install the IC card reader (optional). A black acrylic plate has been installed in the position reserved for the card reader before delivery. Options: four M3 hexagon nuts with flange

Step 3: Install the bracket. Method 1: Install the bracket on the solid slab wall (by default). Options: four M8 bolts (standard) Method 2: Install the bracket on the metal slab wall. Options: four M8x16 bolts, four M8 washers, and four M8 nuts (prepared by users)







Step 4: Install the floor selector. Options: six M3 hexagon nuts with flange

2.3.3 Installing the 10.4-Inch Vertical Touchscreen 1) Product appearance

Notes: 1) The floor selector consists of a touchscreen (MCTC-DDS-T1-IC) and a vertical bracket (MCTC-DDS-T1-B1-IC). 2) If no IC card reader is equipped, install a black acrylic plate in the position reserved for the card reader. 3) Errors in the physical dimensions or differences in the surface textures of different batches of products may exist. The physical dimensions and surface textures are subject to the actual product.

- 23 -

Chapter 2 Mechanical and Electrical Installation

2) Dimensions 200

54.5

20 50 º 40

160

105

72.5

61

212.5

0

4.

135

14

11

199.5

Four M3x6 round head screws and four M3 plain washers 260.5 0 Four M3 R1 selfclinching nuts

115

Screen size

899.91

782.5

101 Dimensions of an IC card

752.5

54.8

72.8 112.4 Dimensions of a black

77

54.5

72.5

1019.5

Four M3x6 countersunk head screws

145

88.2

Four M3x8 countersunk head screws and four M3 hexagon nuts with flange

acrylic plate

30

150

Front view

3) Installation procedure 150

90

Ø6.5

30

36

6

Holes punched in the base

- 24 -

15

30

190

Holes punched in the base

90

120

40

6

30

º

5 6.

36

Ø

90

6

Four M4x12

44

6

Cable outlet hole

200

Right view

countersunk head screws



Step

Step 1: Punch holes in the base, and install the horn. Options: four M3x8 countersunk head screws and four M3 hexagon nuts with flange

Chapter 2 Mechanical and Electrical Installation

Diagram ①



Step 2: Install the IC card reader (optional). A black acrylic plate has been installed in the position reserved for the card reader before delivery. Options: four M3 hexagon nuts with flange Step 3: Install the floor selector. Options: four M3x8 cross recessed screws, four M3 washers, and four M3x8 countersunk head screws.



Step 4: Install the bracket. Options: four M4x12 countersunk head screws



2.3.4 Installing the 15-Inch Wall-Mounted Touchscreen

Notes: 1) The floor selector consists of a touchscreen (MCTC-DDS-T2-IC) and a vertical bracket (MCTC-DDS-T2-B2-IC). 2) If no IC card reader is equipped, install a black acrylic plate in the position reserved for the card reader. 3) Errors in the physical dimensions or differences in the surface textures of different batches of products may exist. The physical dimensions and surface textures are subject to the actual product.

- 25 -

Chapter 2 Mechanical and Electrical Installation

1) Dimensions

Countersunk head screws

15

343.4

50

101



270

Front view 343.4

4

Self-clinching screws

40 º

Hexagon nuts with flange

253.5

11

0

369.17

72.8

112.4

162.32

54.8

98.75

88.2

182

437

Dimensions of an IC card

72.5

7.

65

15

77

54.5

Ø 5. 5

72.5

98.75

26

80

65

39.79

223.36

Dimensions of a black acrylic plate

Side view

Countersunk head screws

314

Hexagon nuts with flange .5

R3

4

R5

200

0

100

130

267.4

200

Ø8

35 146

200 304

Screen view

Rear view

2) Installation procedure

200

60

200 100

60

70

4-

Ø1

0

200

782

Height above ground

Size of holes punched in the sheet metal wall

For details, see the installation of MCTC-DDS-T1 in section "2.3.2 Installing the 10.4-Inch Wall-Mounted Touchscreen".

- 26 -



Chapter 2 Mechanical and Electrical Installation

2.3.5 Installing the 15-Inch Vertical Touchscreen 1) Product appearance

Notes: 1) The floor selector consists of a touchscreen (MCTC-DDS-T2-IC) and a vertical bracket (MCTC-DDS-T2-B1-IC). 2) If no IC card reader is equipped, install a black acrylic plate in the position reserved for the card reader. 3) Errors in the physical dimensions or differences in the surface textures of different batches of products may exist. The physical dimensions and surface textures are subject to the actual product.

2) Dimensions 15 Four M3x6 countersunk head screws

40

35

R

Six M3x6 selfclinching screws and six M3 hexagon nuts with flange

80

343.4 304

65

229 267.4

54.5

30

Ø6

8

19.2

30

40

20

38

90 40.4

Ø6

112.4

901.85

Dimensions of an IC card

54.5

88.2

Ø5 .5

72.8

54.5

80

782.5

4

4.

Screen view

150

Front view

23

104 72.5

250

65

72.5

1073.73

343.4

Base dimensions

32.2

120 200

Top view

- 27 -

Chapter 2 Mechanical and Electrical Installation

3) Installation procedure

47.8

150

90

65.2

Φ6

38

Dimensions of holes punched in the base

For details, see the installation of MCTC-DDS-T1 in section"2.3.3 Installing the 10.4-Inch Vertical Touchscreen".

2.3.6 Installing the Keypad-Type Floor Selector

■■ MCTC-DDS-K1 (the keypad-type floor selector, without IC card function) 1) Product appearance

A 1

2

3

4

5

6

7

8

9



0



Notes: 1) There are floor buttons and a button specialized for disabled passengers. 2) The elevator direction display indicates the location of the assigned car. 3) Braille numbers are embossed on the buttons of the keypad. 4) Errors in the physical dimensions or differences in the surface textures of different batches of products may exist. The physical dimensions and surface textures are subject to the actual product.

2) Dimensions 16

121.6

128

Φ4.5 mounting hole

- 28 -

94

Backplate

15

95

3-Φ4.5*10 mounting hole Φ40 cable outlet hole

293.5 266

125 30

54

A 1

2

3

8

9

4

5



0

7

6

297



Keypad Front view

Keypad Side view



3) Installation procedure

Chapter 2 Mechanical and Electrical Installation

Step

Diagram ①

Step 1: Install the backplate. Options: four M4.5x10 countersunk head screws

① ②

Step 2: Punch holes in the upper part of the floor selector back and insert the upper hooks of the backplate into these holes.

Step 3: Punch holes in the lower part of the floor selector back and insert the lower supports of the backplate into these holes.



■■ MCTC-DDS-K1-IC (the keypad-type floor selector, with IC card function) 1) Product appearance

A 读卡区 Read Area

1

2

3

4

5

6

7

8

9



0



Notes: 1) There are floor buttons and a button specialized for disabled passengers. 2) The elevator direction display indicates the location of the assigned car. 3) Braille numbers are embossed on the buttons of the keypad. 4) Errors in the physical dimensions or differences in the surface textures of different batches of products may exist. The physical dimensions and surface textures are subject to the actual product.

- 29 -

Chapter 2 Mechanical and Electrical Installation

2) Dimensions

 

ď  NPVOUJOHIPMF





 

"

ďDBCMF PVUMFUIPMF  



䈫঑४ 5HDG$UHD





ďNPVOUJOHIPMF



















Ϲ



Nj



LFZQBE 4JEFWJFX

LFZQBE 'SPOUWJFX

#BDLQMBUF

3) Installation procedure

For details, see the installation procedure in section"MCTC-DDS-K1 (the keypad-type floor selector, without IC card function)".

2.3.7 Terminal Description

The floor selector uses CAN communication, and VH3.96-4P terminals are used for wiring. The type and function of these terminals are shown as follows.

1

Function Description

2

CANH

4

GND

3

Terminal Mark +24V/GND CANH/CANL

- 30 -

Remarks

24 V

CANL

Table 2-4 Description of floor selector terminals

Function Description

Keypad-type floor selector

Power interface

CAN communication port used for communication with the GCB



 



Remarks +24V CANH CANL COM

Terminal Mark

Table 2-3 Description of VH3.96-4P terminals

1234



Chapter 2 Mechanical and Electrical Installation

Terminal Mark

Remarks

Touchscreen-type floor selector

Power interface

+24V CANH CANL COM

+24V/GND

Function Description

CAN communication port used for communication with the GCB

CANH/CANL

1234

2.4 Car Display

2.4.1 Dimensions

The following figure shows the dimensions of the car display. Fix the car display with four M4 nuts.

193.6 144±0.2

148.1±0.2

197.2±0.2

Car display

Backplate

240±0.2 250.3

32

Figure 2-2  Mounting diagram of the car display (unit: mm)

2.4.2 Terminal Description

CN1

Function

Modbus communication and power supply terminals; Pins 2 and 3 are for Modbus communication, and pins 1 and 4 are for power supply.

Wiring

+24V MOD+ MODGND

Terminal Name

Table 2-5 Description of the car display input/output terminals

1234

2.4.3 Function Description

The functions of the car display are described as follows:

1) It displays all status information of an elevator, including the running direction, current floor, and overload/full-load information.

2) It displays the destination floors of an elevator to arrive in real time. A maximum of eight nearest stops can be displayed.

- 31 -

Chapter 2 Mechanical and Electrical Installation

NOTE

◆◆ A maximum of eight destination floors can be displayed. If there are more than eight destination floors, the first destination floor display is removed upon arrival, and then the ninth destination floor is displayed.

The following figure shows the car display interface.

3VOOJOHEJSFDUJPO

8JOEPXJNBHF

$VSSFOU珞PPS  %FTUJOBUJPO珞PPST  %JTQMBZUIFPWFSMPBE GBVMUJOGPSNBUJPOJO PWFSMPBEGBVMUTUBUF

Destination floors:

Suzhou Inovance Technology Co., Ltd.

5JNF %BZPGXFFL %BUF

8FMDPNFT

Figure 2-3 Car display interface diagram

NOTE

◆◆ The window image, time, day of week, and date can be modified. For details, consult Inovance.

The following figure shows the car display information in overload or fault state.

Destination floors:

Prompt

Warning: overload

Normal

Overload

Prompt

Warning: fault

Fault

Figure 2-4  Examples of the car display interface

- 32 -



Chapter 2 Mechanical and Electrical Installation

7   (/%

2.5 Wiring of the Elevator Destination Group Control System

- 0 $ " -  3 &.

)[

3 1 .

0 5

' &%  3 &7

"

$/

.$5$($# # ($#

5 6/ & 5 $

$/

7 

1 3 (

$/ . : %0UFSNJOBMT . : : :

& / 5& 3

2 6 *$ ,

3 6/

.' ,

4 50 1 3 &4

7 $"/) $"/$0.

7 $"/) $"/$0.

&MFWBUPS# &MFWBUPS$ &MFWBUPS% &MFWBUPS& &MFWBUPS' &MFWBUPS( &MFWBUPS) 3FTFSWFE 3FTFSWFE

7 $"/) $"/$0.

$/

7 $"/) $"/$0.

&MFWBUPS"

7 $"/) $"/$0. 7 $"/) $"/$0.

$/

$/

$/ 7 $"/) $"/$0.

$/

$/

$/ 7 $"/) $"/$0.

$/

9 9 %*UFSNJOBMT 9 9 9 9 $/ $/ 9 9

$/

7 $"/) $"/$0. 7 $"/) $"/$0.

3 6/

+

$/

7 7%$ QPXFSJOQVU (/%

$PNNPOUFSNJOBM 3FTFSWFE $PNNPOUFSNJOBM 3FTFSWFE 3FTFSWFE 3FTFSWFE

3FTFSWFE 3FTFSWFE 3FTFSWFE 3FTFSWFE 3FTFSWFE 3FTFSWFE 4VEEFOQFBLUSB珟DUSJHHFS #BDLVQQPXFSTVQQMZUSJHHFS

7%$ QPXFSJOQVU

($# 7 $"/) $"/$0.

&MFWBUPS"

$/ 7%$ QPXFSJOQVU

5PQ珞PPS



$/      



   

7 $"/) $"/$0.

7 $"/) $"/$0.

/*$&TFSJFTJOUFHSBUFE FMFWBUPSDPOUSPMMFS



  

   

   

$/

7 $"/) $"/$0.

 7 $"/ $"/  (/%

$/

$"/ $"/ .0% .0% $0. 7

'MPPSTFMFDUPS

$/ $/

$/

'MPPSTFMFDUPS

7 .0% .0% $0.

$5#

$$#

.$5$$5#

.$5$$$#"

$/

#PUUPN珞PPS



  

  





   

'MPPSTFMFDUPS

7 $"/) $"/$0.

$/

7 .0% .0% (/%

$BSEJTQMBZ

.$5$)$#5%%4

/PUF

5IJT珝HVSFTIPXTUIFTUBOEBSEFMFWBUPS HSPVQDPOUSPMTZTUFNXJSJOH*GZPVIBWF TQFDJBMSFRVJSFNFOUT DPOUBDU*OPWBODF 'PSUIFXJSJOHPGDPOUSPMMFSTBOE$$#T  TFFUIFVTFSHVJEFTPGSFMBUFEDPOUSPMMFST

Figure 2-5 Wiring diagram of the elevator destination group control system

- 33 -

Chapter 3 System Commissioning

Chapter 3 System Commissioning 3.1 LED Operating Panel

The LED operating panel can be used to modify parameters, monitor the status and perform other operations to the GCB.

1 Panel introduction

The following figure shows the appearance and function zones of the LED operating panel. Reserved

Reserved

Reserved

RUN

LOCAL/REMOT

FWD/REV

Reserved

TUNE/TC

Data display zone Hz

Programming key

RPM

A

PRG

Reserved

%

Unit indicator

V

Increment key Confirm key

ENTER

Shift key Decrement key Reserved

QUICK

Reserved

RUN

MF.K

STOP RES

Reserved

Figure 3-1 LED operating panel

1) Description of function indicators ■■ RUN: reserved

■■ LOCAL/REMOT: reserved ■■ FWD/REV: reserved ■■ TUNE/TC: reserved

2) Description of unit indicators ( V Hz A % RPM

indicates on;

indicates off)

%: percentage

These indicators are used to display the unit of the value in the LED display zone. If an indicator is on, the corresponding unit is used. If two indicators are on, the unit between them is used. 3) Description of the LED display zone

It is a five-digit LED display, which can display various monitoring data and parameters.

- 34 -



Parameter group

4) Description of keys Key PRG

Chapter 3 System Commissioning

Parameter No.

Table 3-1 Functions of keys

Key Name

Programming Enter or exit Level I menu

Function

Confirm

Enter the menu interfaces level by level, and confirm the parameter settings.

Increment

Increase data or parameter.

Decrement

Decrease data or parameter.

Shift

Select the digit to be modified when modifying a parameter value.

Reserved

-

Reserved

-

MF.K

Reserved

-

QUICK

Reserved

-

ENTER

RUN

STOP RES

2 Viewing and Modifying Parameters

The operating panel of the GCB adopts a three-level menu to perform parameter setting and other operations. The three-level menu consists of parameter group (Level I), parameter (Level II), and parameter setting value (Level III). Figure 3-2 shows the operation procedure.

- 35 -

Chapter 3 System Commissioning

Level I menu (Select the parameter group)

Level II menu (Select the parameter No.)

PRG

Return

F0

If there is a blinking digit, press or to modify the digit. ENTER

PRG

Enter

F0-00

Return ENTER

Abort

F0-02

Enter

1

PRG

Level III menu (Set the parameter value)

,

ENTER

Save

ENTER

Enter Next parameter No.

Figure 3-2 Operation flowchart of the three-level menu

Note:

You can return to Level II menu from Level III menu by pressing

PRG

The difference between the two is as follows:

or

ENTER

.

After you press , the system saves the parameter setting, goes back to Level II menu and automatically shifts to the next parameter. ENTER

After you press , the system does not save the parameter setting, but directly goes back to Level II menu and remains at the current parameter. PRG

Example: Change the value of F2-00 from 0 to100.

F0 F2

PRG

F1

F2

ENTER

F2-00 ENTER

F2-01

ENTER

100

000

000

In Level III menu, if a parameter has no blinking digit, it indicates that the parameter cannot be modified. This may be because such a parameter is only readable, such as an actually-detected parameter or version display parameter.

3 Password Setting

The GCB provides a password protection function. When FP-00 (User password) is set to a non-zero value, it is a user password. The password takes effect after you exit the parameter editing state. After you press

PRG

correct user password to enter level I menu.

, "-----" is displayed. You must enter the

To cancel the password protection function, enter the menu with correct password and then set FP-00 (User password) to 0. If FP-00 (User password) is a non-zero value upon power-on, the parameters are protected by a password.

- 36 -



Chapter 3 System Commissioning

3.2 Operations of the MCTC-DDS-T Series Floor Selector 3.2.1 Interface Description

The display zone of the touchscreen-type floor selector can display the destination floor number, ID and location of a system-assigned elevator, and parameters.

A

ID of a systemassigned elevator