Multi-band Panel Dual Polarization Half-power Beam Width Adjust. Electrical Downtilt Enhanced Sidelobe Suppression

1710 –2690

1710 –2690

X

X

65°

65°

0°– 12°

0°– 12°

18dB

18dB

Downtilt set by hand or by optional RCU (Remote Control Unit) XXPol Panel 1710–2690/1710–2690 65°/65° 18/18dBi 0°–12°/0°–12°T ESLS

80010622

Type No. Frequency range

1710–2690 1920 – 2200 MHz 2200 – 2490 MHz

1710 – 1990 MHz Polarization Gain (dBi) Tilt

2490 – 2690 MHz

+45°, –45°

+45°, –45°

+45°, –45°

+45°, –45°

17.4 ... 17.4 ... 17.3 0° ... 6° ... 12°

17.8 ... 17.6 ... 17.5 0° ... 6° ... 12°

18.0 ... 17.9 ... 17.5 0° ... 6° ... 12°

18.0 ... 17.7 ... 17.3 0° ... 6° ... 12°

Horizontal Pattern: Half-power beam width Front-to-back ratio (180° ±30°) Cross polar ratio Sector

65°

65°

61°

61°

> 25 dB, avg. 28 dB

> 26 dB, avg. 28 dB

> 25 dB, avg. 27 dB

> 25 dB, avg. 27 dB

Typically: 30 dB > 10 dB

Typically: 30 dB > 10 dB

Typically: 25 dB > 8 dB

Typically: 25 dB > 10 dB

6.5°

5.9°

5.7°

0° ±60°

Vertical Pattern: Half-power beam width

7.1°

Electrical tilt

0°– 12°, continuously adjustable

Sidelobe suppression for first sidelobe above main beam

0° ... 6° ... 12° T ≥ 18 ... 18 ... 18 dB

0° ... 6° ... 12° T ≥ 18 ... 18 ... 18 dB

0° ... 6° ... 12° T ≥ 18 ... 17 ... 17 dB

Impedance

50 Ω

VSWR

< 1.5

Isolation, between ports

0° ... 6° ... 12° T ≥ 18 ... 18 ... 17 dB

> 30 dB

Intermodulation IM3

< –150 dBc (2 x 43 dBm carrier)

Max. power per input

300 W (at 50 °C ambient temperature)

1710 – 1990 MHz: +45°/ –45° Polarization 125°

65° 7.1°

dB

3

3

dB

10

10

1710 – 2690 +45°

1710 – 2690 –45°

1710 – 2690 +45°

1710 – 2690 –45°

7-16

7-16

7-16

7-16

0 0

Horizontal Pattern

Vertical Pattern 0°– 12° electrical downtilt

1920 – 2200 MHz: +45°/ –45° Polarization Mechanical specifications 125°

65°

Input

3

dB

dB

3

Wind load

0 0

Horizontal Pattern

Vertical Pattern 0°– 12° electrical downtilt

2490 – 2690 MHz: +45°/ –45° Polarization 110°

61° 5.7°

3

dB

dB

3

Bottom 2 x, Position bottom continuously adjustable Frontal: Lateral: Rearside:

720 N (at 150 km/h) 165 N (at 150 km/h) 740 N (at 150 km/h)

Max. wind velocity

200 km/h

Height/width/depth

1415 / 323 / 71 mm

Category of mounting hardware

M (Medium)

Weight Packing size

10

10

4 x 7-16 female

Connector position Adjustment mechanism

10

10

936.3621/a

Subject to alteration.

6.5°

Scope of supply

17.5 kg / 19.5 kg (clamps incl.) 1706 x 337 x 112 mm Panel and 2 units of clamps for 50 – 115 mm diameter

0 0

Horizontal Pattern Internet: www.kathrein.de

Vertical Pattern 0°– 12° electrical downtilt

80010622 Page 1 of 5

KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973

Accessories General Information

Remarks

Weight approx.

1 clamp

Mast: 50 – 115 mm diameter

1.0 kg

85010002

1 clamp

Mast: 110 – 220 mm diameter

2.7 kg

2 (order separately if required)

85010003

1 clamp

Mast: 210 – 380 mm diameter

4.8 kg

2 (order separately if required)

737978

1 downtilt kit Downtilt angle: 0° – 15°

2.8 kg

1 (order separately if required)

Type No.

Description

738546

72 64 9

20

Accessories Units per antenna 2 (included in the scope of supply)

Material:

Reflector screen: Tin-plated copper. Radiator: Tin-plated zinc. Flat fiberglass radome: The max. radome depth is only 71 mm. Fiberglass material guarantees optimum performance with regards to stability, stiffness, UV resistance and painting. The colour of the radome is grey. All screws and nuts: Stainless steel.

Grounding:

The metal parts of the antenna including the mounting kit and the inner conductors are DC grounded.

1415 1480 1520

For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit. Wall mounting: No additional mounting kit needed.

Environmental conditions: Kathrein cellular antennas are designed to operate under the environmental conditions as described in ETS 300 019-1-4 class 4.1 E. The antennas exceed this standard with regard to the following items: – Low temperature: –55 °C – High temperature (dry): +60 °C Ice protection: Due to the very sturdy antenna construction and the protection of the radiating system by the radome, the antenna remains operational even under icy conditions. Kathrein antennas have passed environmental tests as recommended in ETS 300 019-2-4. The homogenous design of Kathrein’s antenna families use identical modules and materials. Extensive tests have been performed on typical samples and modules.

30 254 48 41 71 98

Environmental tests:

Adjustment mechanism with integrated scale

323 Bottom view –45° –45° RCU +45° +45° 1710–2690 Left Right 1710–2690 RCU

As a result of more stringent legal regulations and judgements regarding product liability, we are obliged to point out certain risks that may arise when products are used under extraordinary operating conditions. The mechanical design is based on the environmental conditions as stipulated in ETS 300 019-1-4 and thereby respects the static mechanical load imposed on an antenna by wind at maximum velocity. Wind loads are calculated according to DIN 1055-4. Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress (e.g. strain caused by oscillating support structures), may result in the breakage of an antenna or even cause it to fall to the ground. These facts must be considered during the site planning process. The installation team must be properly qualified and also be familiar with the relevant national safety regulations. The details given in our data sheets have to be followed carefully when installing the antennas and accessories. The limits for the coupling torque of RF-connectors, recommended by the connector manufacturers must be obeyed. Any previous datasheet issues have now become invalid.

Page 2 of 5 80010622

Internet: www.kathrein.de

KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973

936.3621/a

Please note:

Subject to alteration.

Layout of interface

Mounting Hardware Clamp included in the scope of supply

Suitable for mast diameter Antenna – mast distance F Number of pieces Material of clamp and screws Weight

50 – 115 mm 18 – 26 mm 1 clamp Hot-dip galvanized steel / stainless steel 1.0 kg

Torque MA = G

Torque: M8 => MA = 20 Nm M6 => MA = 8 Nm

A

B

C

D

E

F

G

H

152 mm

40 mm

40 mm

50 –115 mm

93 mm

18 – 26 mm

20 Nm

125 mm

936.3621/a

Subject to alteration.

Washer

Internet: www.kathrein.de

80010622 Page 3 of 5

KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973

General Instructions for Adjustment Mechanism

Description of the adjustment mechanism (protective cap removed):

1

1

2 2

➀ Adjustment wheel with twist-lock function. ➁ Downtilt spindle with integrated scale.

➀ Thread for fixing the protective cap or the RCU (Remote Control Unit). ➁ Gearwheel for RCU power drive.

To set the downtilt angle exactly, you must look horizontally at the scale. The lower edge of the gearwheel must be used for alignment.

Manual adjustment procedure:

0° – max.°

max.° – 0°

Remove the protective cap.

Set downtilt angle by rotating the adjustment wheel.

Screw on the protective cap again.

936.3621/a

Subject to alteration.

Optional: RCU (Remote Control Unit) for remote-controlled downtilt adjustment:

For a description of RCU installation please refer to the respective data sheet. Page 4 of 5 80010622

Internet: www.kathrein.de

KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973

General Instructions for Feederline Installation on Panels with four Connectors arranged on two Levels Please note: In order not to damage the interfaces, please make sure that only the right tools are used. Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench width.

Description of connector arrangement:

4

2

3

1

There are four interfaces for feeding the antenna located at the bottom.

The connectors are mounted at two levels in order to facilitate feederline installation.

Attachment of the feederline connector and RCU (optional): In order to protect the adjustment mechanism the protective caps have to be attached during feederline installation!

Place the connector carefully and fix the nut using a torque-wrench (according to the manufacturers guidelines).

After feederline installation the optional remote control units (RCU) can be mounted if required.

For a full description of RCU installation please refer to the respective data sheet.

The further sequence for the installation is: feederlines no. 2, 3, 4.

936.3621/a

Subject to alteration.

Start with the rearside located interface no. 1.

Please note: Additional weather sealing of correctly installed feederline connector interfaces is not required, nor is it recommended by the connector manufacturers.

Internet: www.kathrein.de

80010622 Page 5 of 5

KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973