57 0 671KB
Multi-band Panel Dual Polarization Half-power Beam Width Adjust. Electrical Downtilt Enhanced Sidelobe Suppression
1710 –2690
1710 –2690
X
X
65°
65°
0°– 12°
0°– 12°
18dB
18dB
Downtilt set by hand or by optional RCU (Remote Control Unit) XXPol Panel 1710–2690/1710–2690 65°/65° 18/18dBi 0°–12°/0°–12°T ESLS
80010622
Type No. Frequency range
1710–2690 1920 – 2200 MHz 2200 – 2490 MHz
1710 – 1990 MHz Polarization Gain (dBi) Tilt
2490 – 2690 MHz
+45°, –45°
+45°, –45°
+45°, –45°
+45°, –45°
17.4 ... 17.4 ... 17.3 0° ... 6° ... 12°
17.8 ... 17.6 ... 17.5 0° ... 6° ... 12°
18.0 ... 17.9 ... 17.5 0° ... 6° ... 12°
18.0 ... 17.7 ... 17.3 0° ... 6° ... 12°
Horizontal Pattern: Half-power beam width Front-to-back ratio (180° ±30°) Cross polar ratio Sector
65°
65°
61°
61°
> 25 dB, avg. 28 dB
> 26 dB, avg. 28 dB
> 25 dB, avg. 27 dB
> 25 dB, avg. 27 dB
Typically: 30 dB > 10 dB
Typically: 30 dB > 10 dB
Typically: 25 dB > 8 dB
Typically: 25 dB > 10 dB
6.5°
5.9°
5.7°
0° ±60°
Vertical Pattern: Half-power beam width
7.1°
Electrical tilt
0°– 12°, continuously adjustable
Sidelobe suppression for first sidelobe above main beam
0° ... 6° ... 12° T ≥ 18 ... 18 ... 18 dB
0° ... 6° ... 12° T ≥ 18 ... 18 ... 18 dB
0° ... 6° ... 12° T ≥ 18 ... 17 ... 17 dB
Impedance
50 Ω
VSWR
< 1.5
Isolation, between ports
0° ... 6° ... 12° T ≥ 18 ... 18 ... 17 dB
> 30 dB
Intermodulation IM3
< –150 dBc (2 x 43 dBm carrier)
Max. power per input
300 W (at 50 °C ambient temperature)
1710 – 1990 MHz: +45°/ –45° Polarization 125°
65° 7.1°
dB
3
3
dB
10
10
1710 – 2690 +45°
1710 – 2690 –45°
1710 – 2690 +45°
1710 – 2690 –45°
7-16
7-16
7-16
7-16
0 0
Horizontal Pattern
Vertical Pattern 0°– 12° electrical downtilt
1920 – 2200 MHz: +45°/ –45° Polarization Mechanical specifications 125°
65°
Input
3
dB
dB
3
Wind load
0 0
Horizontal Pattern
Vertical Pattern 0°– 12° electrical downtilt
2490 – 2690 MHz: +45°/ –45° Polarization 110°
61° 5.7°
3
dB
dB
3
Bottom 2 x, Position bottom continuously adjustable Frontal: Lateral: Rearside:
720 N (at 150 km/h) 165 N (at 150 km/h) 740 N (at 150 km/h)
Max. wind velocity
200 km/h
Height/width/depth
1415 / 323 / 71 mm
Category of mounting hardware
M (Medium)
Weight Packing size
10
10
4 x 7-16 female
Connector position Adjustment mechanism
10
10
936.3621/a
Subject to alteration.
6.5°
Scope of supply
17.5 kg / 19.5 kg (clamps incl.) 1706 x 337 x 112 mm Panel and 2 units of clamps for 50 – 115 mm diameter
0 0
Horizontal Pattern Internet: www.kathrein.de
Vertical Pattern 0°– 12° electrical downtilt
80010622 Page 1 of 5
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973
Accessories General Information
Remarks
Weight approx.
1 clamp
Mast: 50 – 115 mm diameter
1.0 kg
85010002
1 clamp
Mast: 110 – 220 mm diameter
2.7 kg
2 (order separately if required)
85010003
1 clamp
Mast: 210 – 380 mm diameter
4.8 kg
2 (order separately if required)
737978
1 downtilt kit Downtilt angle: 0° – 15°
2.8 kg
1 (order separately if required)
Type No.
Description
738546
72 64 9
20
Accessories Units per antenna 2 (included in the scope of supply)
Material:
Reflector screen: Tin-plated copper. Radiator: Tin-plated zinc. Flat fiberglass radome: The max. radome depth is only 71 mm. Fiberglass material guarantees optimum performance with regards to stability, stiffness, UV resistance and painting. The colour of the radome is grey. All screws and nuts: Stainless steel.
Grounding:
The metal parts of the antenna including the mounting kit and the inner conductors are DC grounded.
1415 1480 1520
For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit. Wall mounting: No additional mounting kit needed.
Environmental conditions: Kathrein cellular antennas are designed to operate under the environmental conditions as described in ETS 300 019-1-4 class 4.1 E. The antennas exceed this standard with regard to the following items: – Low temperature: –55 °C – High temperature (dry): +60 °C Ice protection: Due to the very sturdy antenna construction and the protection of the radiating system by the radome, the antenna remains operational even under icy conditions. Kathrein antennas have passed environmental tests as recommended in ETS 300 019-2-4. The homogenous design of Kathrein’s antenna families use identical modules and materials. Extensive tests have been performed on typical samples and modules.
30 254 48 41 71 98
Environmental tests:
Adjustment mechanism with integrated scale
323 Bottom view –45° –45° RCU +45° +45° 1710–2690 Left Right 1710–2690 RCU
As a result of more stringent legal regulations and judgements regarding product liability, we are obliged to point out certain risks that may arise when products are used under extraordinary operating conditions. The mechanical design is based on the environmental conditions as stipulated in ETS 300 019-1-4 and thereby respects the static mechanical load imposed on an antenna by wind at maximum velocity. Wind loads are calculated according to DIN 1055-4. Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress (e.g. strain caused by oscillating support structures), may result in the breakage of an antenna or even cause it to fall to the ground. These facts must be considered during the site planning process. The installation team must be properly qualified and also be familiar with the relevant national safety regulations. The details given in our data sheets have to be followed carefully when installing the antennas and accessories. The limits for the coupling torque of RF-connectors, recommended by the connector manufacturers must be obeyed. Any previous datasheet issues have now become invalid.
Page 2 of 5 80010622
Internet: www.kathrein.de
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973
936.3621/a
Please note:
Subject to alteration.
Layout of interface
Mounting Hardware Clamp included in the scope of supply
Suitable for mast diameter Antenna – mast distance F Number of pieces Material of clamp and screws Weight
50 – 115 mm 18 – 26 mm 1 clamp Hot-dip galvanized steel / stainless steel 1.0 kg
Torque MA = G
Torque: M8 => MA = 20 Nm M6 => MA = 8 Nm
A
B
C
D
E
F
G
H
152 mm
40 mm
40 mm
50 –115 mm
93 mm
18 – 26 mm
20 Nm
125 mm
936.3621/a
Subject to alteration.
Washer
Internet: www.kathrein.de
80010622 Page 3 of 5
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973
General Instructions for Adjustment Mechanism
Description of the adjustment mechanism (protective cap removed):
1
1
2 2
➀ Adjustment wheel with twist-lock function. ➁ Downtilt spindle with integrated scale.
➀ Thread for fixing the protective cap or the RCU (Remote Control Unit). ➁ Gearwheel for RCU power drive.
To set the downtilt angle exactly, you must look horizontally at the scale. The lower edge of the gearwheel must be used for alignment.
Manual adjustment procedure:
0° – max.°
max.° – 0°
Remove the protective cap.
Set downtilt angle by rotating the adjustment wheel.
Screw on the protective cap again.
936.3621/a
Subject to alteration.
Optional: RCU (Remote Control Unit) for remote-controlled downtilt adjustment:
For a description of RCU installation please refer to the respective data sheet. Page 4 of 5 80010622
Internet: www.kathrein.de
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973
General Instructions for Feederline Installation on Panels with four Connectors arranged on two Levels Please note: In order not to damage the interfaces, please make sure that only the right tools are used. Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench width.
Description of connector arrangement:
4
2
3
1
There are four interfaces for feeding the antenna located at the bottom.
The connectors are mounted at two levels in order to facilitate feederline installation.
Attachment of the feederline connector and RCU (optional): In order to protect the adjustment mechanism the protective caps have to be attached during feederline installation!
Place the connector carefully and fix the nut using a torque-wrench (according to the manufacturers guidelines).
After feederline installation the optional remote control units (RCU) can be mounted if required.
For a full description of RCU installation please refer to the respective data sheet.
The further sequence for the installation is: feederlines no. 2, 3, 4.
936.3621/a
Subject to alteration.
Start with the rearside located interface no. 1.
Please note: Additional weather sealing of correctly installed feederline connector interfaces is not required, nor is it recommended by the connector manufacturers.
Internet: www.kathrein.de
80010622 Page 5 of 5
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973