IPX S@E MANAGER Manual

Code 720081038-A0-GB ed.2 del 7/2004

Index Introducing the IPX configuration program ........................................................... 7 IPX S@E MANAGER structure ............................................................................ 7 Minimum PC requirements .................................................................................... 7 Software installation ............................................................................................... 8 Removing the software ......................................................................................... 12 Running the software ............................................................................................ 13 IPX S@E MANAGER configurations ................................................................. 13 Local connection between the S@E exchange and PC ...................................... 16 Modem connection between S@E exchange and PC ........................................... 17 IPX S@E MANAGER anti-intrusion function .................................................... 17 Description of function keys ................................................................................ 19 Description of windows graphics objects ............................................................. 20 IPX S@E MANAGER ......................................................................................... 22 Example of CLIENT - SERVER configuration ................................................... 23 Example of CLIENT - Packet Processor configuration ....................................... 25 DEFINING THE APPLICATION DEFAULT VERSION .................................. 26 ACTIVATING THE APPLICATION PROGRAMS .......................................... 26 COMMUNICATIONS SUBSYSTEM ................................................................ 27 MANAGEMENT OF USER LOGIN .................................................................. 27 LANGUAGE MANAGEMENT .......................................................................... 27 Dialog Box: FILE \ ESC .................................................................................. 29 Dialog Box: Configuration / Routing tables / node address ........................... 30 Dialog Box: Configuration / Routing tables / Routing record ........................ 31 Dialog Box: Configuration / SW version icon association .............................. 32 Dialog Box: Application start .......................................................................... 32 Dialog Box: Communications / serial port management ................................. 33 Dialog Box: Services / language management selection ................................. 33 Dialog Box: Services / language management / new language ....................... 34 Dialog box: Services / user profiles ................................................................. 35 Dialog box : Services / password ..................................................................... 36 Dialog Box: Services / SW version / general .................................................. 36 Dialog Box: Services / SW versions / product code ....................................... 37 Dialog box : Services / Print ............................................................................ 37 Dialog Box: Help ............................................................................................. 38 IPX S@E BUILDER ............................................................................................ 41 Guide to compile a system for S@E IPX, SAE 3000 and SAE PLUS exchanges 43 System Submenu .................................................................................................. 48 Dialog Box: New / Free creation ..................................................................... 49 Dialog Box: New / Model creation .................................................................. 51 Dialog Box: New / Wizard .............................................................................. 52 Dialog Box: Open ........................................................................................... 53 Dialog Box: Save as / Equipment .................................................................... 54 Dialog Box: Save as / Model ........................................................................... 55 Dialog Box: Delete / System ........................................................................... 56 Dialog Box: Delete / Model ............................................................................. 57 Dialog Box: Close ............................................................................................ 57

IPX S@E MANAGER Manual

1

Index Insert Tables Submenu ........................................................................................ 58 Dialog Box: Numbering plan ........................................................................... 60 Dialog Box: Equipments .................................................................................. 62 Dialog Box: Local Users ................................................................................. 70 Dialog Box: Attendant Console ....................................................................... 74 Dialog Box: Trunk Line ................................................................................... 76 Dialog Box: Direct Dialling line ...................................................................... 78 Dialog Box: Voice Announcements ................................................................ 80 Dialog Box: Dect ............................................................................................. 81 Management of 16CAUn Virtual Groups and related wireless DECT units ... 82 Configuration of DECT System Details .......................................................... 84 RFP Radio Station Customization ................................................................... 85 Sequence to follow for the DECT system customization procedure ............... 86 Dialog box: Mixed group T1CAS for USA Market ........................................ 86 Dialog box: CAUA long distance .................................................................... 88 Dialog box: Packet Processor group ................................................................ 89 Licences management for Packet Processor function ..................................... 91 IP lines configuration ....................................................................................... 93 Configuring Packet Processor Gateway (Q-sig lines) ..................................... 93 Configuring CAUn section (IP telephones) ..................................................... 94 Configuring Dsp area ....................................................................................... 96 Configuring Lan Telephony area ..................................................................... 97 Configuring IP address .................................................................................... 98 Configuring Trace Flags .................................................................................. 99 Configuring Modem area ............................................................................... 100 Dialog Box: Internal ...................................................................................... 101 Dialog Box: Multifunction terminal .............................................................. 102 Dialog Box: DSS Terminal (K module) ........................................................ 103 Dialog Box: Hunt groups ............................................................................... 104 Dialog Box: Pick up groups ........................................................................... 105 Dialog Box: Intercommunication user groups ............................................... 106 Dialog Box: Message from absent user ......................................................... 107 Dialog Box: Known network dialling conversion ......................................... 107 Dialog Box: Free Sequences .......................................................................... 108 Dialog Box: Financial Operator ..................................................................... 109 Dialog Box: Account Code ............................................................................ 111 Dialog Box: Multiproperty blocks ................................................................. 112 Dialog Box: Public network Access .............................................................. 112 Dialog Box: Bundle ....................................................................................... 114 Dialog Box: Forbidden trunk line number ..................................................... 115 Dialog Box: Direct Inward dialling conversion ............................................. 116 Dialog Box: DID particular Characteristics and telephone number .............. 116 Dialog Box: Timed Billing Plan .................................................................... 117 Dialog Box: Private network Access ............................................................. 118 Dialog Box: Paths .......................................................................................... 119 Dialog Box: groups for forbidden nos. .......................................................... 120

2

IPX S@E MANAGER Manual

Index Dialog Box: Routings .................................................................................... 121 Dialog Box: Incoming direct dialling selection conversion .......................... 122 Dialog Box: Outgoing direct dialling selection conversion .......................... 123 Dialog Box: DDNS Activation ...................................................................... 124 Dialog Box: VPN network characteristics / Exchange data .......................... 124 Dialog Box: VPN network characteristics / Network data / Numbering plan 125 Dialog Box: VPN network characteristics / Network data / Telephone numbers 125 Dialog Box: Backup on public network ........................................................ 126 Dialog Box: Association Trunk lines name/Language .................................. 127 Dialog Box: VOIP ......................................................................................... 128 Dialog box: Voip Gateway data .................................................................... 129 Dialog Box: Modem area ............................................................................... 136 Dialog box: Suite over IP ............................................................................. 137 Dialog Box: Speed numbers .......................................................................... 141 Dialog Box: Service Classes .......................................................................... 142 Dialog Box: Prefixes ...................................................................................... 143 Dialog Box: Suffixes ..................................................................................... 144 Dialog Box: General ...................................................................................... 145 Dialog Box: Language ................................................................................... 146 Dialog Box: Timing constants ....................................................................... 146 Dialog Box: General logical characteristics .................................................. 147 Dialog Box: General number characteristics ................................................. 147 Dialog Box: Logical tones ............................................................................. 148 Dialog Box: print format tables ..................................................................... 148 Dialog Box: Passwords .................................................................................. 149 Dialog Box: Service documentation peripherals ........................................... 150 Dialog Box: General system parameters ....................................................... 150 Dialog Box: GP CAUA Characteristics ........................................................ 151 Dialog Box : GP ALU Particular customizations .......................................... 151 Dialog Box : GP 8CLG Particular customizations ....................................... 151 Dialog Box: GP Annvoc particular customizations ....................................... 152 Dialog Box: Special terminations .................................................................. 152 Dialog Box: ISDN service characteristics ..................................................... 153 Dialog Box: Level attenuation table .............................................................. 154 Dialog Box: License file loading ................................................................... 154 Dialog Box: Alarm priority ........................................................................... 155 Dialog Box: Identifier of caller/connected subscriber elaboration ................ 156 Dialog Box: Least Cost Routing .................................................................... 156 Dialog Box: LCR numbering plan ................................................................. 157 Dialog Box: LCR Dialling conversion .......................................................... 158 Dialog Box: Add LCR digits ......................................................................... 159 Dialog Box: LCR time table .......................................................................... 159 Compilation Submenu ........................................................................................ 160 Dialog Box: Check correctness ..................................................................... 160 Dialog Box: Reverse compilation .................................................................. 162 Communication Submenu .................................................................................. 163

IPX S@E MANAGER Manual

3

Index Dialog Box: From Personal Computer to S@E ............................................. 164 Partial transfer ................................................................................................ 166 Total transfer .................................................................................................. 169 Dialog Box: From the S@E exchange to a Personal Computer .................... 170 CRC Request ................................................................................................. 171 Total transfer .................................................................................................. 172 Services Submenu .............................................................................................. 173 Dialog Box: Language selection .................................................................... 173 Dialog Box: Search with key ......................................................................... 174 Dialog Box: Prints ......................................................................................... 178 Dialog Box: Permutator documentation ........................................................ 178 Dialog Box: Last report ................................................................................. 180 Telephone status Submenu ................................................................................. 182 Dialog Box: Line telephone status inspection ............................................... 183 Dialog Box: Multiproperty block telephone status inspection ...................... 184 Dialog Box: Attendant Console telephone status inspection ......................... 185 Dialog Box: Inspection of conference timeslot telephone status ................... 186 Dialog Box: Inspection of all lines excluded from traffic ............................. 187 Dialog Box: Esc/Rein of a line from telephone traffic .................................. 187 Dialog Box: One line forced release .............................................................. 188 Dialog Box: Current master inspection for synchronism .............................. 188 Dialog Box: Peripheral group type inspection ............................................... 189 Dialog Box: Peripheral group status inspection ............................................ 189 Dialog Box: Current traffic inspection .......................................................... 190 Dialog Box: Supplementary service inspection ............................................. 190 Diagnostics Submenu ......................................................................................... 191 Dialog Box: On line alarm display ................................................................ 192 Dialog Box: Controlled switching of CU and reset ....................................... 193 Dialog Box: Peripheral Group Reset ............................................................. 194 Dialog Box: Diagnostic control reset ............................................................ 195 Group management Submenu ............................................................................ 196 Dialog Box: Vocal Announcement group management ................................ 197 Dialog Box: ISDN group management .......................................................... 199 Dialog Box: VPN group management ........................................................... 202 Group status inspection .................................................................................. 202 Inspection of VPN Spare customization Data ............................................... 204 Dialog Box: DECT system management ....................................................... 207 RFP Status and manage inspection ................................................................ 208 PP DECT status inspection ............................................................................ 208 Dialog Box: Card T1 Management ................................................................ 209 Dialog Box: Fidelio interface management ................................................... 210 Dialog Box: Packet Processor management ................................................. 211 Utility Submenu ................................................................................................. 213 Dialog Box: Equipped software version check ............................................. 215 Dialog Box: Date time Display/Modific. ....................................................... 216 Dialog Box: Debug Function ......................................................................... 217

4

IPX S@E MANAGER Manual

Index Dialog Box: TRACE display of connected application ................................. 219 Dialog Box: Program upgrade ....................................................................... 220 Dialog Box: Courtesy announcement update ................................................ 220 Dialog Box: Autoloader ................................................................................. 220 Dialog Box: TDM Processor (or GT) Rate Change ...................................... 221 Dialog Box: Time at which timed customization was activated ................... 221 Dialog Box: Call up ap_numtelsi table .......................................................... 222 Dialog Box: Absolute relative pos.conversion ........................................ 222 Communication Submenu .................................................................................. 223 Services Submenu .............................................................................................. 223

IPX S@E MANAGER Manual

5

Index

6

IPX S@E MANAGER Manual

IPX S@E MANAGER Chapter 1 IPX S@E MANAGER 1. 1 Introducing the IPX configuration program The purpose of this manual is to provide operating instructions for using the S@E IPX system customization and maintenance programs. The term IPX S@E MANAGER is used to indicate the management platform applied for S@E IPX exchanges: both the LARGE and PLUS, implemented in a WINDOWS 95 / 98 / 2000 /NT /XP. This platform currently permits you to perform CUSTOMIZATION and MAINTENANCE activities using STAND ALONE or CLIENT/SERVER configurations. Connection to the S@E IPX exchange can be made using the following physical supports: - local RS232 serial connection - remote connection by modem (V22 or V22bis or V23) using the internal MODEM located in the PG US on the S@E IPX side; - remote connection by modem using the external modem on the S@E IPX side.

1. 2 IPX S@E MANAGER structure The IPX S@E MANAGER management platform is currently of three separate modules: - IPX S@E MANAGER root program. This program lets you configure the management environment, activate all the other IPX S@E MANAGER modules (applications) and manage the subsystems handling communication with the S@E exchange available from the other IPX S@E MANAGER modules; - IPX S@E BUILDER application program. This program lets you generate the configuration for the S@E IPX exchange (system), save it to a local or network hard disk, upload it to the S@E exchange or download it from the S@E exchange using the IPX S@E MANAGER communications subsystem; - IPX S@E VIEW application program. This program lets you connect to the S@E exchanges and perform on-line maintenance (view base working data, perform diagnosis, hardware resource recovery,...) using the IPX S@E MANAGER communications subsystem.

1. 3 Minimum PC requirements To run the IPX S@E MANAGER platform you need: - PENTIUM 233 MHz, - 64 Mb RAM, - 60 Mb hard-disk space, - SVGA monitor with 800 x 600 pixel resolution and large characters

IPX S@E MANAGER Manual

7

IPX S@E MANAGER - 14"/15" color monitor - PS2 compatible mouse, - asynchronous serial interface, - parallel interface, - IEEE 802.3 network card (for CLIENT / SERVER configuration) - any WINDOWS 95/98/NT p 4.0 compatible parallel printer. - 3.5" floppy disk drive - CD-ROM drive - Sound Blaster or compatible sound card.

1. 4 Software installation Software can be added and removed using standard Windows 95 procedures through the supplied Setup program. Three separate installations must be performed: - installation of the IPX S@E MANAGER root program (the communications subsystem) - installation of the IPX S@E BUILDER application (the configuration application) - installation of the IPX S@E VIEW program (the maintenance application). Several IPX S@E MANAGERs, with different communications subsystems, each with its own IPX S@E BUILDER and IPX S@E VIEW applications can be installed in a single PC. To make this possible, each IPX S@E MANAGER must be installed in a different directory. Install the IPX S@E MANAGER before installing the IPX S@E BUILDER and IPX S@E VIEW applications so that they will be properly linked to the IPX S@E MANAGER. Never install the IPX S@E MANAGER while any Windows applications are open. This is an essential precaution for installation. Likewise never install any other Windows applications while IPX S@E MANAGER is open. If installation were performed with the IPX S@E MANAGER open, the Data Base Engine configuration files could be initialized by mistake, causing the IPX S@E MANAGER and/or the other Windows applications to malfunction. In this case it is best to uninstall and reinstall the IPX S@E MANAGER and the other Windows applications. The default IPX S@E MANAGER installation directory is c:\programs\IPX S@E MANAGERxyy although you can modify this directory during the installation procedure. The default IPX S@E BUILDER è installation directory is: c:\programs\IPX S@E BUILDERxyy while the default directory for IPX S@E VIEW is: c:\ programs\IPX S@E VIEWxyy. You can modify these installation directories during the installation procedure. To overwrite an older release of IPX S@E BUILDER or IPX S@E VIEW with a more recent release, the first must be uninstalled.

8

IPX S@E MANAGER Manual

IPX S@E MANAGER When adding a IPX S@E BUILDER or IPX S@E VIEW release to a IPX S@E MANAGER that can support them, the installation directory does not have to correspond to the IPX S@E MANAGER directory. The important thing is that the installation disk must be the same. The disk handles the installation procedure for both the IPX S@E MANAGER and the IPX S@E BUILDER and IPX S@E VIEW applications in the same manner. - Initially a window appears prompting you to close all open Windows applications and indicating copyright. Press "Next" to move to the next screen where you can edit the user and company names. - The next step establishes the directory where the files are to be installed; if you opt for the default directory, press "Next". - Then you give a name for the application folder under the operating system Programs menu. - At this point decompression and installation of the files begins. - When this phase is complete you are prompted to reboot the PC to activate the program. You can do this immediately by confirming the prompt. After the PC has been rebooted you can add the IPX S@E MANAGER icon to the PC desktop following the normal copy and paste operations, right clicking with the mouse. When running the Setup program, you can interrupt the procedure at any time by pressing Quit or pressing the standard close window button found on the title bar of all windows (the button marked "x"). This calls up another window warning you that if you exit the program at this point installation will not be completed although you can install the program later. If you decide to quit Setup anyway, press "Exit Setup" or close the window. If you want to continue installation, press "Continue". Acronyms used HW: HARDWARE SW: SOFTWARE PC: Personal Computer TDM Processor: Traffic management

Installation of IPX S@E MANAGER program in Windows NT/2000/XP O.S. The installation of IPX S@E MANAGER program (all the versions) on Windows NT/2000/XP O.S. (Workstation/Professional type) must be done by the administrator of the system (or by a user that has the same rights of administrator). All the users with rights of administrator can perform IPX S@E MANAGER without effecting further configurations of system. If the File System is a NTFS type, the administrator must execute the following operations to give users/groups, without administrator rights, the possibility to execute IPX S@E MANAGER, IPX S@E BUILDER and IPX S@E VIEW:

IPX S@E MANAGER Manual

9

IPX S@E MANAGER - assign to the interested users/groups the rights of complete access to the directories where Suite programs have been installed. For instance, if some programs, ver. XXX, have been installed in c:\programmi, or in any else disk of network, then the directories of installation will be: c:\programmi\ IPXS@EMANAGERXXX, c:\programmi\ IPXS@EBUILDERxxx, c:\programmi\ IPXS@EVIEWXXX.

- The operation must be done by the administrator opening the "Property" applet from "Explore Resource" of the directories (right key of the mouse). In the "Protection" page (see figure below) you must add the users you want to enable to use "IPX S@E MANGERXXX", therefore assign to each of them the complete control on the access.

- For the regular operation of BDE (Borland Database Engine) modul, on which the IPX S@E MANAGER applications are founded, it is necessary to manage the file PDOXUSRS.NET; it is used to manage the complete access to Paradox tables. The file is created by the BDE in the root C:\, to check such position, select from the Panel of Control, the BDE Administrator applet and in page "Configuration" read the parameter NET DIR (in the following figure the NET DIR is in C:\).

10

IPX S@E MANAGER Manual

IPX S@E MANAGER

- ·Assign to PDOXUSRS.NET file the complete control on the access, the operation must be done by the administrator opening the "Property" applet of the file from "Explore Resource" (right key of the mouse), therefore assign to every consumer the complete control on the access.

- IPX S@E MANAGERXXX applications to regularly work, must have complete access to the following key of the Registry: HKEY_LOCAL_MACHINE\SOFTWARE\MICROSOFT\WINDOWS\CURRENTVERSION\APP PATHS\SUITEXXX.EXE

- The third step therefore, consists on assigning the authorization to the interested users/groups to completely access the registry key HKEY_LOCAL_MACHINE. Such operation can be done with the program REGEDT32.EXE that you can start from "Menu Start->Execute..". Once selected the key [email protected] (see figure below), assign the complete rights of reading and writing to the desired users/groups through menu Protection->Authorization.

IPX S@E MANAGER Manual

11

IPX S@E MANAGER

- With "Add..." button (see figure below) you can add the users/groups you want to enable to the change of the key of the register. For each of them, in the low part, you must select all the check box of the "Allow" page.

1. 5 Removing the software As for installation, the IPX S@E MANAGER and the IPX S@E BUILDER, IPX S@E VIEW applications connected to the IPX S@E MANAGER must be uninstalled separately.

12

IPX S@E MANAGER Manual

IPX S@E MANAGER Remember that the IPX S@E BUILDER and IPX S@E VIEW applications can only be activated by their own IPX S@E MANAGER. Therefore, if you uninstall the IPX S@E MANAGER you will be unable to run the IPX S@E BUILDER and IPX S@E VIEW applications it handles. To regain the ability to run these applications, you must reinstall the same IPX S@E MANAGER release which was removed and in the same directory previously used. Each individual IPX S@E MANAGER program (IPX S@E MANAGER, IPX S@E BUILDER, IPX S@E VIEW) can be removed from the Control Panel (accessible from the Start menu selecting Settings or opening the Resources icon on the Windows 95 desktop), Applications Installation folder and selecting the application you want to uninstall and then selecting Add/Remove. If the Remove tab is not in the foreground, select it and, at the bottom on a white background, the program presents a list of applications that can be removed from the system. Select the program you want to remove and press Remove. Wait until the operations required to remove the application and all its components have been completed, then close the window for the Applications Bar. Uninstalling the IPX S@E BUILDER program does not remove any systems it has created.

1. 6 Running the software To run the IPX S@E MANAGER you must select, and confirm, one of the following: - IPX S@E MANAGER in the PROGRAMS submenu under START; - or the IPX S@E MANAGER icon on the PC desktop. The IPX S@E BUILDER and IPX S@E VIEW applications associated with a IPX S@E MANAGER are activated from the main IPX S@E MANAGER dialog box, as described in this document.

1. 7 IPX S@E MANAGER configurations The IPX S@E MANAGER management platform can be arranged in three distinct configurations: 1.7.1 STAND ALONE Configuration Stand alone configuration is a configuration where one management PC uses one of its serial (COMx) ports to communicate with several S@E exchanges connected either locally or remotely by modem; at any given moment the PC can be running both a IPX S@E BUILDER and a IPX S@E VIEW communications session either to a single SAE exchange or to two different SAE exchanges. Two simultaneous connections can run between a PC and a S@E exchange, using two distinct serial lines: one for IPX S@E BUILDER and one for IPX S@E VIEW.

IPX S@E MANAGER Manual

13

IPX S@E MANAGER

Fig. 1 IPX S@E MANAGER Stand Alone with local connection to a S@E

Fig. 2 IPX S@E MANAGER Stand Alone with local connection to two S@Es

Fig. 3 IPX S@E MANAGER Stand Alone with remote connection

14

IPX S@E MANAGER Manual

IPX S@E MANAGER

Fig. 4 IPX S@E MANAGER Stand Alone with double connection to one S@E

1.7.2 CLIENT / SERVER Configuration Client/server configuration is a configuration where several management PCs are connected in a LAN NETWORK for which the Server is a PC connected to one or more S@E exchanges either locally through serial lines or remotely by modem (two serial lines can be connected to a single S@E exchange) the Clients are those PCs managing the S@E exchanges connected to the Server PC; for each Client PC the assumptions made for the Stand Alone PC hold in terms of number of sessions that can be handled simultaneously and types of connections that can be activated with a single S@E exchange.

Fig. 5 Client-server configuration on LAN Ethernet

1.7.3 Remote configuration with IP connection The third way to reach S@E IPX is with IP connection using Packet Processor card.

IPX S@E MANAGER Manual

15

IPX S@E MANAGER The architecture of the solution provides for connection of the serial port of the Client PC directly to the Packet Processor which performs the server function to date performed by the PC Server with IPX S@E Manager. For a description of the physical connections refer to the S@E IPX Installation Manual, code 723106006-A0-GB, paragraph "Packet Processor connections".

Fig. 6 Remote configuration with IPX S@E MANAGER of a S@E with IP connection

The procedure to configure the IPX S@E MANAGER platform in one of the two above-mentioned modes is described in the chapter dealing with the IPX S@E MANAGER, under "node address" and "routing tables" tables.

1. 8 Local connection between the S@E exchange and PC The cable used to connect the personal computer to the S@E Service Unit contains the following connections:

Personal Computer

S@E

25/9 pole female serial connector

RJ45 8/8 pole

signal

pin

pin

signal

CD

8/1

8

CD

RX

3/2

2

TX

TX

2/3

1

RX

DTR

20/4

5

DSR

SG

7/5

6

SG

DSR

6/6

7

DTR

16

IPX S@E MANAGER Manual

IPX S@E MANAGER

Personal Computer

S@E

25/9 pole female serial connector

RJ45 8/8 pole

RTS

4/7

4

CTS

CTS

5/8

3

RTS

22/9 N.C. (Not Connected) 1. 9 Modem connection between S@E exchange and PC The cable used to connect the personal computer to the modem contains the following connections.

Personal Computer

MODEM

25/9 pole female serial connector

8 pole female plug jack

signal

pin

pin

signal

CD

8/1

8

CD

RX

3/2

3

TX

TX

2/3

2

RX

DTR

20/4

20

DSR

SG

7/5

7

SG

DSR

6/6

6

DTR

RTS

4/7

4

CTS

CTS

5/8

5

RTS

22/9 N.C. (Not Connected)

1. 10 IPX S@E MANAGER anti-intrusion function The IPX S@E MANAGER platform provides the user with an anti-intrusion procedure for the IPX S@E MANAGER environment. This anti-intrusion procedure is based on management of two distinct levels of login: each with its own password within the IPX S@E MANAGER environment. These levels are:

IPX S@E MANAGER Manual

17

IPX S@E MANAGER - Administrator: enabling access to all IPX S@E MANAGER functions; - User: enabling access to a group of functions configured by the administrator when creating the user. The administrator has the right to create different user profiles, enabling or disabling the individual IPX S@E MANAGER and IPX S@E BUILDER / IPX S@E VIEW functions according to the responsibilities, competencies or particular applications to be performed. Once the IPX S@E MANAGER has been used (by the ADMINISTRATOR) to define a USER with its own "password" and its own "user profile" (containing the individual functions enabled for all applications), this user can be stationed on the PC where the IPX S@E MANAGER environment has been defined.The program cannot delete the ADMINISTRATOR database record (utenti.db) and the ADMINISTRATOR cannot change its own profile since all IPX S@E MANAGER functions are enabled. The ADMINISTRATOR cannot view the password of the various users, although it can modify them using the anti-intrusion procedure in the "user profile" table. It is possible to insert a user having access to the user profiles; that is a user that can modify the profiles of all system users although what was previously mentioned for the Administrator still holds. The first time the IPX S@E MANAGER is booted, only the Administrator login is available. Therefore, once the Login window appears, to access the IPX S@E MANAGER you must type in the default ID for the Administrator (User = Administrator, Password = Administr). Remember that only "User" is CASE SENSITIVE. Description of the procedure to create/modify/delete a login and its password and related user profile as well as to modify a password are described in the chapter regarding the IPX S@E MANAGER "user profile" and "password" tables.

18

IPX S@E MANAGER Manual

IPX S@E MANAGER 1. 11 Description of function keys The IPX S@E MANAGER programs handle cursor management as all standard Windows applications, using mouse and PC function keys. In particular, the following functions have been assigned the function keys.

pressing this key in the various menus lets you select the highlighted item (even when in the Combo Box);

from the parameter configuration Dialog Boxes, this key lets you confirm the entire content or confirm the content of a single field. pressing this key in the various menus lets you deselect the menu;

from the parameter configuration Dialog Boxes, this key lets you exit without saving the modifications; in general, it lets you close Windows without having performed any functions. in the Main menu these arrows let you shift through the options; by default the first item on the menu and the first item its submenu (if available) are selected if the "wrap around" function is activated;

Left/Right Arrows

on the Pop-up menus, these arrows let you access any sub-items; from the parameter configuration Dialog Boxes, these arrows let you shift between characters within a field or to scroll through any lists. on the Pop-up menus, these arrows let you scroll from one option to anther when the "wrap around" is activated;

Up/Down Arrows from the parameter configuration Dialog Boxes, these arrows let you shift between characters within a field or to scroll through any lists.

from the parameter configuration Dialog Boxes, these arrows let you shift from one field to another, confirming the data input; they also let you shift from one function button to the other.

like but in the opposite direction.

this deletes the character to the right of the cursor or the entire content if the field is highlighted.

this deletes the character to the left of the cursor or the entire content if the field is highlighted.

this positions the cursor to the left of the first character within any field where alphanumerical input is possible.

this positions the cursor to the right of the last character within any field where alphanumerical input is possible.

this lets you "Scroll" down through a page if this function is available for the Window.

this lets you "Scroll" down through a page if this function is available for the Window.

Remember that the left clicking with the mouse normally positions the cursor and activates the selected function.

IPX S@E MANAGER Manual

19

IPX S@E MANAGER In some forms of the IPX S@E MANAGER-specified in the corresponding paragraphs (i.e. service classes)-the right mouse key is also enabled; right clicking calls up a list of available options valid according to the context of that dialog box.

1. 12 Description of windows graphics objects The IPX S@E MANAGER displays and handles a series of Windows graphics objects following the classic manner. These objects let you view and select the available options according to the context of that dialog box. The following is a brief description of the graphics objects used.

Fig. 7 Pop-up Menu Windows

Fig. 8 OK - Cancel Button

Fig. 9 Check Boxes

Fig. 10 Spin Box

Fig. 11 Drop-down Combo Box

Fig. 12 Tab Controls

20

IPX S@E MANAGER Manual

IPX S@E MANAGER

Fig. 13 Static Text

Fig. 14 Simple Line Text Box

Fig. 15 Tree View

Fig. 16 Message Box

Fig. 17 Tooltip ControlDrop-down List Box

IPX S@E MANAGER Manual

21

IPX S@E MANAGER

Fig. 18 Single-Selection List Box

Fig. 19 Tool Bar

Fig. 20 Main Bar

The Tool Bar also has a colored indicator light indicating the status of the S@E unit connection; the following information is reported: black:

no communication

red:

connection in progress

yellow: data link connected green: S@E session active

1. 13 IPX S@E MANAGER As previously mentioned the IPX S@E MANAGER management platform is comprised of a root program called the IPX S@E MANAGER which provides the functions the other IPX S@E MANAGER applications programs need to perform their specific tasks. The IPX S@E MANAGER automatically activates the IPX S@E MANAGER application program when he login and the IPX S@E MANAGER user-generated password are typed in. [Default: User:Administrator, Password:Administr]

22

IPX S@E MANAGER Manual

IPX S@E MANAGER BASIC IPX S@E MANAGER-PROVIDED FUNCTIONS: ENVIRONMENT CONFIGURATION in other words, definition of the: - nodes comprising the IPX S@E MANAGER-that is, the PCs comprising the management configuration (STAND ALONE or CLIENT \ SERVER)-and the S@E exchanges being managed; - routing, letting you reach the S@E exchanges from the work PC through each of their SERVER PCs;

1. 14 Example of CLIENT - SERVER configuration PRELIMINARY OPERATIONS FOR CLIENT - SERVER CONFIGURAITON The operations described below to configure the nodes and routing records must be known by all elements of the network involved: Client PC, Server PC and Client/Server PC; the S@E units must be known to the address attributed to them. To establish a communications session between the Client PC and a S@E unit, the Server PC must be connected through a LAN network and all parameters for the communications subsystem must be configured. Run a customization session from the IPX S@E MANAGER on Client1. The Client1 PC is connected to the S@E2 exchange connected locally to the Server1 PC through a LAN network. Since the IP addresses for the PC are dynamic and are attributed when the Server is turned on, they must be made static. This operation is performed as follows (Windows 95): - CONTROL PANEL; - NETWORK - CONFIGURATION; - select the network card (i.e. TCP/IP->3COM Ethernet III ISA (3C509b-Combo) in PnP mode); - PROPERTY; - IP ADDRESS; - set the IP ADDRESS SPECIFICATIONS field; - type in the address to be assigned, i.e. SERVER1: 10.0.3.190, CLIENT3: 10.0.3.192; the last number must start from the last value assigned by the network administrator (i.e.190). - OK - You can check the address assigned to the PC with the "winipcfg" command, performed under to "start" "execute".

IPX S@E MANAGER Manual

23

IPX S@E MANAGER Perform the following operations: SERVER PC - From IPX S@E MANAGER on PC Server, to customize "Node Address" table, under "Local PC Parameter" Tab control, input the name you want to assign to the PC (i.e. Server1) in the "Name" field, input a number (i.e. 1) in the "Progressive" field, and the value automatically calculated by the program appears in the field "Equipment address" (i.e. 8). Under "General" Tab control, input the name you want to assign to the exchange (i.e. S@E2) in the "Name" field; input a number (i.e. 2) in the "Progressive" field, and the value automatically calculated by the program appears in the "Equipment address" field (i.e. 16). When you have finished the operation, click "OK" to confirm. - Program the "Routing record", by clicking on "New" button, and a new "Insert S@E unit" dialog box will appear. In the "Name" field, select the name to the S@E (i.e. S@E2); in the "Application" field, select the application (i.e. KEYBUILDER); in the "Connection" field, select the desired PC communications port (i.e. COM2). Click on "Configure" to call up the "Port settings" dialog box. Set the correct parameters and confirm by clicking "OK". When you have finished this operation, click "OK" on both boxes to confirm. - Exit the IPX S@E MANAGER program and reboot it to make the modifications operative for the local PC parameters. - To check that configuration has been performed correctly: physically connect the serial port of the SERVER PC (i.e. COM2), to the first serial port of the S@E. Start the IPX S@E VIEW application, access the "Communication" menu, "Activate communication" option and, in the dialog box, select the name of the desired exchange (i.e. S@E2). Confirm by clicking "OK"; under "Configuration parameters" option, use the default configuration and click "OK" to confirm your choice. This starts the communication session: at the prompt, type in the "password" field (i.e. PAROLA2) and check that connection is made between the SERVER PC and the S@E. CLIENT PC - From IPX S@E MANAGER on PC Server, to customize "Node Address" table, under "Local PC Parameter" Tab control, input the name you want to assign to the PC (i.e. Client1) in the "Name" field, input a number (i.e. 3) in the "Progressive" field, and the value automatically calculated by the program appears in the "Equipment address" field (i.e. 24). When you have finished the operation, click "OK" to confirm. - Select "General" Tab control and click on "New" button to call up the "Node characteristics" dialog box: - Click on PC option: type into "Name" field you previously assigned for the SERVER PC (i.e. Server1); type the number previously assigned for the SERVER PC (i.e. 1) into the "Progressive" field; the value automatically calculated by the program appears in the "Unit Address" field (i.e. 8); type the network node number for the SERVER PC in the "IP Address" field (see preliminary operations) (i.e. 10.0.3.190). When you have finished the operation, click "OK" to confirm. Select "New" and the "Node characteristics" dialog box will call up again. - Click on S@E option: Type the name previously assigned to the exchange for the SERVER PC (i.e. S@E2) into the "Name" field; type the number previously assigned for the exchange on the SERVER PC (i.e. 2) into the "Progressive" field; the "Unit address" field will show the automatically calculated value. When you have finished the operation, click "OK" to confirm. - Program the "Routing record" dialog box, select "General" Tab control and click on "New" button to call up the "Insert S@E unit" dialog box. - In the "Name" field, select the name assigned for the exchange (i.e. S@E2); in the "Application" field, select the application (i.e. KEYBUILDER); in the "Connection" field, select the "LAN" network configuration. In the "Server name" field select the name previously assigned (i.e.

24

IPX S@E MANAGER Manual

IPX S@E MANAGER Server1) and the "IP Address (server PC)" field automatically displays the address for the SERVER PC node connection (i.e. 10.0.3.190). When you have finished the operation, click "OK" to confirm. - Exit the IPX S@E MANAGER program and reboot it to make the modifications operative for the local PC parameters. To check that configuration has been performed correctly: physically connect the SERVER PC serial port (i.e. COM2) to the first serial port of the S@E, connect the SERVER and CLIENT PCs to the LAN network. From the CLIENT PC run the IPX S@E VIEW application, access the "Communications" menu and in the "Activate communication" dialog box, select the name of the selected exchange (i.e. S@E2) and the "default" parameter. Confirm your choice by clicking "OK"; at the "Configuration parameters" option, use the default configuration and click "OK" to confirm your choice. This starts the communication session: at the prompt, type in the "password" field (i.e. PAROLA2) and check that connection is made between the SERVER PC and the S@E.

1. 15 Example of CLIENT - Packet Processor configuration The Packet Processor card on which the remote management operations of the exchange can be carried out is the one that hosts the main D channel with gateway functions (the gateway function must hence be active in order to be able to use remote management). The Packet Processor card must be configured by the customizer connected locally to the exchange (the first customization must in any case be done locally) as follows: STEP 1 - Configuring the routing table from IPX S@E Manager The Packet Processor card must be configured as PC node and the US, connected to the Packet Processor, as S@E node. Configure the routing records for both the IPX S@E Builder and the IPX S@E View application specifying that the connection is via LAN. STEP 2 - Customizing Suite-OnSite IPX Manager from IPX S@E Builder The data required by the software (SUITE - ON SITE IPX MANAGER) which acts from the IPX S@E Manager onboard the Packet Processor can be customized on the following page which is opened from the menu: Insert tables->VoIP->Suite on IP

IPX S@E MANAGER Manual

25

IPX S@E MANAGER

- The first field defines the node name represented by the Packet Processor card. - The second field defines the node number represented by Packet Processor card. - The third field defines the node name represented by the S@E to which the Packet Processor card is connected. - The fourth field defines the node number represented by the S@E to which the Packet Processor card is connected.

1. 16 DEFINING THE APPLICATION DEFAULT VERSION The IPX S@E MANAGER lets you define the default version to be activated for each application (IPX S@E BUILDER, IPX S@E VIEW)

1. 17 ACTIVATING THE APPLICATION PROGRAMS The IPX S@E BUILDER and IPX S@E VIEW programs

26

IPX S@E MANAGER Manual

IPX S@E MANAGER 1. 18 COMMUNICATIONS SUBSYSTEM The IPX S@E MANAGER provides the communications subsystem for the IPX S@E MANAGER applications, enabling an exchange of messages between the general management CLIENT PC and the general S@E exchange being managed so that they are totally transparent to the applications themselves

1. 19 MANAGEMENT OF USER LOGIN The IPX S@E MANAGER enables you to define, according to anti-intrusion function, which user logins can access the IPX S@E MANAGER from the local PC. It lets you define an access password and a user profile for each containing a list of the functions enabled for each of the IPX S@E MANAGER programs

1. 20 LANGUAGE MANAGEMENT The IPX S@E MANAGER lets you: - modify the language used in all written messages issued and all warnings the IPX S@E MANAGER sends the operator; - arrange the IPX S@E MANAGER to send written messages in another language. The IPX S@E MANAGER automatically activates the IPX S@E MANAGER application program when the login and the IPX S@E MANAGER user-generated password are typed in.

IPX S@E MANAGER Manual

27

IPX S@E MANAGER

The IPX S@E MANAGER desktop menu presents pop-up submenus and a tool bar with a certain number of icons. These let you quickly access the principal IPX S@E MANAGER functions. The following figures show the pop-up submenus used to access the configuration data input Dialog Boxes (forms) used for the normal menu items.

Fig. 21 "Configuration" menu

Fig. 22 "Application Start" menu

28

IPX S@E MANAGER Manual

IPX S@E MANAGER

Fig. 23 "Communication" menu

Fig. 24 "Services" menu

On the other hand, the TOOL BAR is made up of a series of context-sensitive icons. This means that the items may or may not be enabled depending on the current working context. The tool bar is made up of the following icons: - NODE ADDRESS - ROUTING RECORD - SW VERSION ICON ASSOCIATION - IPX S@E BUILDER, IPX S@E VIEW ENABLING - SERIAL PORT MANAGEMENT - LANGUAGE MANAGEMENT/SELECTION - SW VERSION - NEW LANGUAGE - USER PROFILES - HELP The functions associated with each icon on the tool bar are the same functions accessed through these items on the main menu. Below you will find a description of the DIALOG BOXES you can call up from the main menu or the TOOL BAR.This description is not particularly detailed because the IPX S@E MANAGER help, and in particular the CONTEXT SENSITIVE help, greatly facilitate both understanding of the functions you can activate from each dialog box and the choice of options you can set for each field.

Dialog Box: FILE \ ESC This lets you exit the IPX S@E MANAGER as long as no application (IPX S@E BUILDER, IPX S@E VIEW) is running. To exit you must confirm (clicking OK) at the prompt.

IPX S@E MANAGER Manual

29

IPX S@E MANAGER Dialog Box: Configuration / Routing tables / node address

This lets you link each logic S@E unit or PC in the IPX S@E MANAGER environment with a physical address to be used to make connection between PC and S@E. The program automatically generates this physical address starting from the progressive number you have typed in. The TCP/IP address to be used within the LAN network environment must be specified for the defined PCs (these addresses are derived using the "ping network_user_name" command in Norton Commander or with "winipcfg"command executived from "start" "executive" of Windows). Among the PCs defined, you must specify which unit is the local PC.

30

IPX S@E MANAGER Manual

IPX S@E MANAGER Dialog Box: Configuration / Routing tables / Routing record

For each S@E exchange managed by the LOCAL PC, this dialog box lets you define the configuration needed to route the incoming routing management message it receives. The dialog box lets you define only the routing to the S@E exchanges defined in the NODE ADDRESS table. This is done by specifying the following information for each: - the physical communications path available for connection. This can be: - a COMx or a MODEM if the LOCAL PC acts as the SERVER PC for the exchange - a LAN network if the SERVER PC is any PC other than the LOCAL PC; the choice can be made selecting from among those in the NODE ADDRESS TABLE; - the IPX S@E MANAGER application can use the defined routing since two separate serial connections can be defined and used with a single S@E exchange. For each direct connection to the LOCAL PC, the characteristic connection parameters must be configured using another dialog box: - for local connections: Baud Rate, Character length, Parity, Stop Bit; - for remote connections: type of Modem, manual or automatic configuration mode, Baud rate, command string.

IPX S@E MANAGER Manual

31

IPX S@E MANAGER Dialog Box: Configuration / SW version icon association

IPX S@E MANAGER lets you manage several versions of the same application (IPX S@E BUILDER, IPX S@E VIEW). This dialog box provides the APPLICATION START submenu or a special icon on the TOOL BAR lets you define which release you want to run for each application, selecting it from those available.

Dialog Box: Application start Selecting one of the items in this submenu starts the related application. At the present time only the IPX S@E BUILDER and IPX S@E VIEW applications can be started. An application cannot be booted if it is already running.

32

IPX S@E MANAGER Manual

IPX S@E MANAGER Dialog Box: Communications / serial port management

This Dialog Box lets you enable/disable access to the LOCAL PC serial port for the IPX S@E MANAGER applications. This function provides privileged access to these ports for the other PCresident windows applications.

Dialog Box: Services / language management selection

IPX S@E MANAGER Manual

33

IPX S@E MANAGER This Dialog Box lets you select which of the available languages to use in all IPX S@E MANAGER dialog boxes, all diagnostic messages and all help boxes.

Dialog Box: Services / language management / new language

This dialog box enables skilled operators to add new languages to the list of LANGUAGES handled by the IPX S@E MANAGER; this is done by linking the files (DLL) containing a translation of all the text presented into the new language.

34

IPX S@E MANAGER Manual

IPX S@E MANAGER Dialog box: Services / user profiles

This dialog box lets you define a new IPX S@E MANAGER user and modify, delete and view an existing IPX S@E MANAGER user. For each user the following information must be defined: - a LOGIN with a minimum length of 1 character, maximum length 9 characters; - a PASSWORD with a maximum length of 9 characters. The password input procedure requires confirmation of the word typed in without echoing the typed characters on the screen. - a USER PROFILE containing indication of all the IPX S@E MANAGER program functions (IPX S@E MANAGER included) enabled for that user; the application presents a dialog box for each function. A special user, the ADMINISTRATOR, has access to all available functions, including the ability to create a new user. You cannot modify the ADMINISTRATOR's profile. You can create other users who can also access all available functions.

IPX S@E MANAGER Manual

35

IPX S@E MANAGER Dialog box : Services / password

This dialog box is enabled for all IPX S@E MANAGER users and permits the general user to modify his own password. The password input procedure requires confirming the word typed in without echoing the typed characters on the screen

Dialog Box: Services / SW version / general

This dialog box lets you input the codes for the SW release for the selected application and the TDM Processor SW to establish compatibility.

36

IPX S@E MANAGER Manual

IPX S@E MANAGER Dialog Box: Services / SW versions / product code

This dialog box lets you set the product codes for the TDM Processor (or GT) the IPX S@E BUILDER application uses to establish compatibility.

Dialog box : Services / Print

This dialog box lets you print the tables containing the data set by the IPX S@E MANAGER.

IPX S@E MANAGER Manual

37

IPX S@E MANAGER You can print a single table or all the tables.

Dialog Box: Help

The HELP dialog box is structured in three separated folders: - CONTENTS providing a list of topics you can choose to view; a single topic can be structured in a series of paragraphs; - INDEX this presents a list of topics. Search through this list by typing in the first letters of the desired item; - SEARCH

38

IPX S@E MANAGER Manual

IPX S@E MANAGER this presents a list of keywords. Search through this list by typing in the first letters of the desired item; once you have selected the desired keyword, you can view a series of related topics for the IPX S@E MANAGER.

IPX S@E MANAGER Manual

39

IPX S@E MANAGER From the opened dialog box the operator can start the dialog box help context by clicking the "Dialog box help"

(see the following figures):

Helpful is the "help context to the field" that describes every single field, every option to set in the fields, every function of a dialog box. To activate the "help context to the field" just click on "?" (question mark) present on the tool bar of every window, move the question mark on the field or on the button for which you asked for help, and click on it; it calls up the help that describes the field, the button etc. as the following figure shows.

40

IPX S@E MANAGER Manual

IPX S@E BUILDER Chapter 2 IPX S@E BUILDER 2.1 IPX S@E BUILDER IPX S@E BUILDER is the IPX S@E MANAGER application program that lets you configure the data to be sent to the S@E exchanges managed. In detail the main IPX S@E BUILDER functions are: Input configuration data - creating a PARADOX-format archive called SYSTEM; Compile configuration data - that is, direct compilation of the system data-from the PARADOX format to a format that can be understood by the S@E exchange-and inverse compilation of the system data from the S@E exchange format to the IPX S@E BUILDER PARADOX format; Transfer configuration data - that is, direct (partial or total) downloading of the IPX S@E BUILDER-set system data to a S@E exchange and inverse uploading of the S@E exchange system data to IPX S@E BUILDER. The main IPX S@E BUILDER desktop menu presents pop-up submenus and a tool bar with a certain number of icons. These permit rapid access to the principle IPX S@E MANAGER functions handled.

IPX S@E BUILDER is organized in a series of submenus, each broken down into a set of dialog boxes comprising the customization program.

IPX S@E MANAGER manual

41

IPX S@E BUILDER The submenus are: • • • • •

EQUIPMENT INSERT TABLES COMPILATION COMUNICATION SERVICES

Below is an overview of the dialog boxes comprising the submenus and the general functions they perform. Tool Bar The main menu contains a Tool Bar used to quickly access menu functions; the tool bar is made up of a series of icons and some information regarding the operator-selected system. It enables you to quickly access a subgroup of functions and is context sensitive. This means that the items may or may not be enabled depending on the current working context. The tool bar is made up of the following icons:

- Open system

- New system

- Save system as

- System eliminate

- Equipment

- Numbering plan - Voip

- Check Correctness

- Reverse compilation

- From PC to S@E

- From S@E to PC

42

IPX S@E MANAGER manual

IPX S@E BUILDER

- Language selection

- Last report

- Help

- Search by key - SeltaTelnet The following information is presented on the tool bar for the operator-selected system: - name of system and type of associated S@E exchange; - status of communication with the S@E exchange.

2.2 Guide to compile a system for S@E IPX, SAE 3000 and SAE PLUS exchanges The present document has the purpose to compile a guide for the configuration of S@E IPX, SAE 3000 or SAE Plus systems starting from the beginning. Possible helps are: the use of a system model or the use of the Wizard, that are not described here, for explaining all the necessary steps for the configuration of a complete system. Select the dialog box "System – New - Free creation " and choose the type of system and the path to save the system. Select the technical card "Numbering plan" and configure the numbering plan according to specific demands. To correctly make this operation it is necessary first to establish what kind of numbering to assign to the following principal typologies: - local users for single access; - local users for access to group; - if terminations are foreseen on ISDN S0 interface: - local users for ISDN S0 terminations for single access; - local users for ISDN S0 terminations for access to group; - if Attendant Consoles are foreseen: - attendant console for generic access; - attendant console for individual access; - single trunk lines; - bundles (groups of trunk lines); - generic access to the public network; - if the use of more managers is foreseen to access the public network: - access to the public network with Least Cost Routing (LCR) mode;

IPX S@E MANAGER manual

43

IPX S@E BUILDER - prefixes of access to speed number tables; - prefixes of service; - number of telesupervision; - if the system must belong to a private network: - single tie lines; - routes (groups of tie-lines); - users of private network configured on remote exchanges; - indexes of routing to be used for individualizing every exchange configured in the private network. It is routine to reserve number “0” for generic access or LCR to the public network and number “9” for the generic access to the operator, use numbers of five or six digits for the bundles, the single trunk lines, the direct dialling trunk lines, the single tie-lines that are not object of direct dialling from users. This last shrewdness allows to save ranges of numeration for the services of call really used. Open the "Equipments" dialog box and insert the interested peripheral groups, configure their terminations and their characteristics (initially to all terminations the class of service number 1 can be left and all the other default characteristics, these configurations are further described); the list of electronic groups is the following: 4CAU: 4-connection group for internal users with analog telephones; 16CAU: 16-connection group for internal users with analog telephones; 8CAU: 8-connection group for internal users with analog telephones; 16CAUN: Group with 16 connections for internal users with digital telephones; 8CAUN: Group with 8 connections for internal users with digital telephones; 8ALUBid: Group with 8 connections for bi-directional trunk lines; 4ALUbid: Group with 4 connections for bi-directional trunk lines; 8ALUsp: Group with 8 analog trunk line connections with direct inward dialling; 4ALUnb: Group 4 base ISDN (BRA) access interface T; 2ALUnb: Group 2 base ISDN (BRA) access interface T; 8CLG: Group for 8 tie line connections; 4CLG: Group for 4 tie line connections; AV: Voice announcement group; ALUna: Group for 2 Mbit/s line with 30 digital trunk line connections to associated channel; ALUnc: Group for Primary 2MBit/s ISDN (PRA) interface E1; CGQSIGN: Group for 2MBit/s interface E1 with Q_SIG protocol;

44

IPX S@E MANAGER manual

IPX S@E BUILDER 8CGQSIGA: Group with 8 connections for 2/4 wire analog Ties with Q_SIG protocol; 4CGQSIGA: Group with 4 connections for 2/4 wire analog ties with Q_SIG protocol; 4CGQSIGB: Group 4 base (BRA) access interface T with Q_SIG protocol; 4CAUnS0: Group 4 base (BRA) ISDN access Interface S; VPNS: Single VPN (Virtual Private Network) Group equivalent to a CGQSIGN group; VPND: Integrated double VPN (Virtual Private Network) group equivalent to two CGQSIGN groups; 3T01S0: Integrated group made up of: 4ALUnb with 3 base ISDN access (BRA) with T interface; 4CAUnS0 with 1 base ISDN (BRA) access with S0 interface. 4/2AbdCN: Integrated group made up of: 8ALUbid: as a subset of 4 connections in the 8ALUbid group; 16CAU: as a subset of 2 connections in the 16CAU group; 16CAUn: as a subset of 2 connections in the 16CAUn group. CGNG703/4: G703 remoting interface connected to the SAE REM 4 exchange; CGNG703: G703 remoting interface connected to the SAE REM 12 exchange; CGNHDSL/4: remoting HDSL interface connected to the SAE REM 4 exchange; CGNHDSL: remoting HDSL interface connected to the SAE REM 12 exchange; US: Service Unit Group; Fidelio US: Fidelio Service Unit Group; USS: Integrated group made up of: 16CAUn: as a complete 16CAUn group, but simulated by the Firmware. In other words, they are not actually returned outside the local digital interface, rather the Firmware simulates the action of telephone numbers that can make and receive calls; US: as a complete US group; 2T2CA2CN: Integrated group made up of: 4ALUnb as a subset of 1 or 2 base ISDN (BRA) accesses to the T0 interface; 4CAUnS0: as a subset of at most one base ISDN (BRA) access to the T0 interface. If this access is used, only one T0 interface access can be used.

IPX S@E MANAGER manual

45

IPX S@E BUILDER 16CAU: as a subset of 2 connections in the 16CAU group; 16CAUn: as a subset of 2 connections in the 16CAUn group. DECT: system made up of: a maximum of 4 8RFPI cards (a base card and other expansion cards); a maximum of 32 base RFP DECT radio stations (8 for each 8RFPI card); a maximum of 192 portable DECT units. T1 CAS: mixed group for the USA market with max. 24 lines broken down into a max. of 3 different sections with 4, 8, 12, 16, 20, or 24 modularity, selected from among the following four types: - CAUa - CLG - ALUBid - ALUSp decadic - ALUSp DTMF T1 PRA: 1.5 Mbit/s group with Primary (PRA) T1 interface with 24 lines for the USA market. 8ALUR2: The 8alur2 group makes no. 8 analog trunk line connections with R2 interface. ALUnaR2: The ALUnaR2 group makes no. 30 analog trunk line connections with signal association and R2 interface. Packet Processor: mixed unit for managing IP connections and allows the following configuration: - 1 QSIG group - 2 QSIG group - 1 CAUn group - 2 CAUn groups - 2 groups: 1 QSIG and 1 CAUn - 3 groups: 1 QSIG and 2 CAUn - 3 CAUn groups - 4 CAUn groups - 4 groups: 1 QSIG and 3 CAUn Each QSIG card has 30 channels and each 16CAUN card has 16 terminations for IP telephones. CAU BL: The CAU BL group realizes n. 6 attacks for internal extensions with local battery telephones Open “Extensions” menu to customize the following tables: - Multifunctional terminal and module K terminal configure the profiles of numerical telephones, therefore return on the Equipment table and assign the profiles to the terminations;

46

IPX S@E MANAGER manual

IPX S@E BUILDER - Hunt groups (for the service of hunt groups generally used); - Pick up groups (for the service of generic pick up of a call toward a user of the group, generally used); - the other fields are to be configured only if you need of particular services. Open “Public network access” menu to customize the following tables: - "Bundles", grouping the outgoing or bi-directional trunk lines in different bundles according to the demands; the grouping in bundles has the principal purpose to differentiate the access of the extensions according to their class of service; if no difference is necessary, all the outgoing or bidirectional lines can be inserted in only one bundle and enable all the extensions to its use; - "Forbidden trunk numbers", to configure, if you have to disable some extensions according to the class of service, some particular numbers (for instance the payment services 166 or the international calls); - "Timed billing plan" if you want to use the specific optional service; - the other sections have to be compiled only if you need the relative particular service. Open from "Least Cost Routing" menu, in case you want to use more managers to access to the public network, the tables: "LCR numbering plan” (where customize the time slots and the managers to use for the different grouping of numbers), "Add LCR digits" (where customize the code of access to the different managers) and "LCR time slots" (where customize the weekly time slots). Open “Private network access” menu to customize the following tables: - "Routes", grouping the tie-lines in routes that normally represent the physical channels of connection among exchanges in a private network; - "Routings", defining the direct "Routes" and the "Routes" forwarded for every routing defined in the numbering plan; - the other sections have to be compiled only if you need the relative particular service. Open “Classes of service” the menu to customize the enabling profiles for the extensions and the external lines. Since the default value assigned to all the terminations is Class number 1, you must assign to it the qualifications that are intended to give to the majority of the terminations. Then, it is necessary to define the other classes of service. Finally, return to the “Equipment” menu to assign the class of services different from 1, to the various terminations. Open "Prefixes" menu to enable the services demanded and particularly the prefix "Reserved for maintenance" otherwise the “Check accuracy” operation gives an error. Configure "Suffixes" table to enable the services demanded. Customize "Speed numbers" table grouping them in twenty tables according to specific demands. The fundamental characteristics for the configuration of the system have been defined, possible changes or additions can subsequently be made without following a particular sequence.

IPX S@E MANAGER manual

47

IPX S@E BUILDER Perform a direct compilation of the equipment from the "Compilation – Check accuracy" menu and correct possible signalled errors. Perform a total transfer of the equipment from the menu "Communication - From S@E to PC". Following changes can be performed, compile and loaded through a partial loading (that doesn't involve the connection cut of the possible communications in progress).

2.3 System Submenu

Under "System" in the main menu you will find the functions able to: - Create a new system (the term "system" is used to indicate a general configuration for a S@E exchange) using the "New" or "Save as" options. - Select "Open" to view or modify the content of an existing equipment. - Select "Save as" to make a copy of an existing equipment. - Select "Elim" to delete an existing equipment. You can also create a new equipment: - Using the "Save as" option. This creates the tables for the operator-named equipment by copying them from an existing equipment; - Using the "Free creation" option. In this case you must indicate the type of S@E exchange, the equipment name and the destination directory; - Using the "Model creation" option. In this case, after having indicated the equipment name and destination directory, you must select from a list of model equipments: the program automatically creates the tables for the new equipment using the data from the selected model. There is at least one reference model for each type of S@E exchange; - Using the "Wizard" (guided creation) option. In this case, after having indicated the equipment name and destination directory, you must fill out the dialog box containing some of the key equipment parameters for the new equipment. The program then automatically creates all the tables with this data, adjusted for the required characteristics. The characteristic equipment parameters indicate the number and type of terminals and the range for the numbering plan. You can create new equipments with the various types of S@E exchanges in the following two families: - IPX IPGATE Line is composed of S@E 300 IPX, S@E 100 IPX, S@E 50 IPX systems

48

IPX S@E MANAGER manual

IPX S@E BUILDER - IPX IPGATE ENTERPRISE Line is composed of S@E 2000 IPX, S@E 1000 IPX, S@E 500 IPX, S@E 200 IPX systems - Plus Line is composed of SAE 260, 160, 80, 32 systems - Large Line is composed of SAE 2000, 1000, 500, 220 systems. Remember, a equipment (or a model) is considered "open" when its name appears as the current equipment on the Tool Bar. In reality, however, the equipment files are all closed until you really access one of its Dialog Boxes; once a Dialog Box is open, you cannot open any additional equipments. Also remember that you cannot open more than one equipment at a time and that a single equipment can only be opened by one program at any given time (when an application accesses the equipment tables either locally or from another PC on the network, all equipment tables are Locked. In other words, until this access is terminated, they are no longer available for any other applications). The program provides a "Scroll ..." function to enable you to open a model or a equipment located on another personal computer on the network or, in general, in a directory other than the standard directory (Equipments or Models).

Dialog Box: New / Free creation

With this means of creation the program prepares all the equipment tables for the type of S@E exchange indicated using only default initializations; the data base generated is, therefore, made up of a series of files containing default values. You must then configure the equipment data using the dialog boxes in the "INSERT TABLES" menu.

IPX S@E MANAGER manual

49

IPX S@E BUILDER

This window is divided into the following sections: - an equipment name field (a Single Line Text Box); - a path input field (a Single Line Text Box); - an exchange selection field. To facilitate selection of exchange type, this field presents bit map images of several different exchanges; - a view-only field presenting a list of the data base files comprising the equipment (created with a Single-Selection List Box); - a driver selection field where you can indicate the disk drive where you want to save the new equipment (created with a Drop-down List Box); - a path field shown as a directory tree (created with a Tree View) Any error messages are presented in a special Message Box.

50

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: New / Model creation

With this creation mode the program uses the reference model you have selected from the models on file to prepare all equipment tables for the S@E exchange. In the "create new equipment from model" procedure, the dialog box prompts you for the name of the starting model and the name of the equipment you want to generate from this model. After confirming the data input in the dialog box, the program copies all the files for the model into the destination directory which will hold the newly generated equipment. You can use the new model-generated equipment directly or modify it using the dialog boxes in the "INSERT TABLES" menu.

A list of the model equipments is displayed on the screen in a Single-Selection List Box.

IPX S@E MANAGER manual

51

IPX S@E BUILDER Dialog Box: New / Wizard

As previously mentioned, this option lets you generate a congruent, functional exchange configuration by prompting you to input only a few key parameters. The parameters the program needs to configure the exchange are listed below: - Telemaintenance plug - Telemaintenance reserved prefix - SNUG Telnum - Number and type of Local Extensions; - Number of Attendant Consoles; - Number and type of Trunk Lines; - Number and type of Networking Lines; - Number and type of ANNVOC Group; - Whether the equipment can be outfit with mixed groups - Range of values for each type of Type of Numbering: within one type, you can also specify the range of subtypes (i.e. in the case of local extensions, you can specify the range of general values or the range of values for the individual types of local extensions, or for the Analogic or Digital local extensions). Using the operator-supplied data, the program automatically creates all the equipment tables containing the data adjusted to the required characteristics. The automatic configuration data base creation process takes place as follows: - An adequate number of electronic groups is created to cover the required number of terminals - The equipment is configured with priority going to the larger groups (i.e.: in the case of 20 internal analogic extensions, the program inserts one 16CAUA group and one 4CAUA group; on the other hand in the case of 21 of the same type of extensions, the program inserts one 16CAUA group and one 8CAUA group, leaving 3 extension attachments free) and keeping in mind whether or not you have opted to use mixed electronic groups. You can optimize electronic group assignments after the equipment has been created. This is done using the dialog boxes under the "INSERT TABLES" menu. - The program automatically creates a numbering plan that conforms with the indicated range of values. - All the remaining equipment data are then configured, starting from the reference values in the models for the type of exchange selected. - A graphic equipment diagram is created showing the values the wizard has automatically assigned for the characteristic parameters of the equipment created.

52

IPX S@E MANAGER manual

IPX S@E BUILDER Once the process has been completed, you are notified of any incongruent data. You can modify the characteristics of this newly created equipment using the Dialog Boxes under the "INSERT TABLES" menu (after automatic generation using the wizard, the equipment is the same as any other manually generated equipment). Any error messages are presented in a special Message Box.

Dialog Box: Open To reach this option, select the following items in order: "Equipment" in the main menu, "Open". This option lets you select a equipment from among those in the equipment archive: this archive is a list of the operator-created equipments which may reside locally or be housed in another personal computer on the network.

The window displays the list of equipments which you can select through a Single-Selection List Box. Any error messages are presented in a special Message Box.

IPX S@E MANAGER manual

53

IPX S@E BUILDER Dialog Box: Save as / Equipment

This function lets you create a new equipment starting from an existing equipment: the data for this equipment are copied into the tables for the new equipment. The equipment is saved in the archive holding all the equipments, identified by the operator-selected path.

The window has the following sections: - name of the original equipment to be copied (presented in a Static text) - a equipment name field (a Single Line Text Box); - a path input field (a Single Line Text Box); - a view-only field presenting a list of the data base files comprising the equipment (created with a Single-Selection List Box); - a driver selection field where you can indicate the disk drive where you want to save the new equipment (created with a Drop-down List Box); - a field showing the path as a directory tree (created with a Tree View).

54

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: Save as / Model

This function lets you create a new model equipment starting from an existing equipment: the data for the original equipment are copied into the tables for the new model being created. The new equipment model is added to the model equipment archive.

The window has the following sections: - name of the original equipment to be copied (presented in a Static text) - field for introduction of the model equipment name (created as a Single Line Text Box); - a path input field (a Single Line Text Box); - a view-only field presenting a list of the data base files comprising the equipment (created with a Single-Selection List Box); - a driver selection field where you can indicate the disk drive where you want to save the new equipment (created with a Drop-down List Box); - a field showing the path as a directory tree (created with a Tree View).

IPX S@E MANAGER manual

55

IPX S@E BUILDER Any error messages are presented in a special Message Box.

Dialog Box: Delete / System

This option lets you select the equipment you want to delete from among those filed in the equipment archive: the current equipment cannot be deleted if one of the dialog boxes is open. Moreover no equipment can be deleted if it is "open", being viewed or modified by another personal computer on the network.

The window displays the list of equipments which you can select through a Single-Selection List Box. You are prompted to confirm the request to delete the equipment and any error messages are presented in a special Message Box.

56

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: Delete / Model

This option lets you select the model you want to delete from among those filed in the model archive: the current model cannot be deleted if one of its the dialog boxes is open. Moreover no model can be deleted if it is "open" being viewed or modified by another personal computer on the network.

The window displays the list of equipments which you can select through a Single-Selection List Box. You are prompted to confirm the request to delete the equipment and any error messages are presented in a special Message Box.

Dialog Box: Close This option lets you close the current equipment. When "Close" is selected, the program closes the current equipment. This closes the equipment files and removes the equipment name from the Tool Bar (along with any information regarding the type of exchange); a blank space is left in its place. Closing the archive also unlocks it.

IPX S@E MANAGER manual

57

IPX S@E BUILDER All the items on the menu and their icons are disable except for "New", "Open", "Delete", "Close" and "Exit" in the "Equipment" menu.

2.4 Insert Tables Submenu The INSERT TABLES submenu lets you set the configuration data you want to assign to a new system or to an existing system opened with the system submenu.

To insert the S@E system into the telephone network environment, you must provide a series of data specifying the characteristics; these data mainly refer to the : - numbering plan adopted; - unit configuration in reference to the equipment groups and lines; - line organization; - functions enabled so the user can access the services available on the unit; - operating and timeout modes for the unit; - special performance. A certain number of Dialog Boxes are used to input these data. A Dialog Box contains a series of logically related fields. Once editing has been completed the content of these Boxes is saved in a relational Data Base file in Paradox format. When you select a Dialog Box, its screen appears. The fields in the selected Dialog Box can contain: - initial settings, automatically assigned by the program; - data drawn from the TAPER constructed at the end of the "TRANSFER TABLES FROM S@E TO PC";

58

IPX S@E MANAGER manual

IPX S@E BUILDER - characters typed from the keyboard. In selecting the setting for a given field, whenever operator input is possible, the program guides you through this by presenting a list of correct settings (i.e. range for the numbering plan or telephone number for the configured terminals); in addition, in other cases the program presents a list of correct numbers which are already being used. These numbers cannot be used. Two levels of controls are performed on the data input in the general Dialog Box: - Local Control (achieved during the "Insert Tables" phase) - Cross Checking between Boxes (achieved during the "Compilation" phase) In particular, local controls are performed: - when the data input in a field are confirmed (these controls serve to ensure that the setting input falls within the acceptable range); - when the entire content of the Dialog Box is being confirmed (these controls serve to ensure that the values input in the various fields are congruent with each other). When inputting data in a single Dialog Box, a part of the cross checks involving that dialog box are performed if they are not too time consuming. The program performs the same controls when data are introduced in the dialog box and during the inverse compilation procedure. The data inserted in the various fields of a Dialog Box are only memorized in the Data Base on the HD when you exit the Dialog Box and only upon operator request. As previously mentioned, the program is structured so that you are required to complete some of the configuration steps before proceeding with the next (the "Numbering Plan" table must be configured before all the other tables and immediately after the "Equipment" table has been configured). This simplifies data input since it is often possible select the value from automatic lists; it also simplifies compilation since it reduces the number of cross checks needed. In particular, in defining the configuration data, the following chronological order must be a satisfied: - before customizing the peripheral group (PG) terminals equipped in the system ("EQUIPMENT" dialog box), the accepted ranges for those types of terminals must be customized in the NUMBERING PLAN; - before customizing the mixed telephone groups (hunt groups, arrays, paths, ...) both the numbering plan ranges and the terminals included must have been customized; - before customizing any system telephone entity, the corresponding range must have already been customized in the numbering plan Accessing the individual dialog boxes: - Numbering plan - Equipments - Internal - Multiproperty blocks - Public network Access - Private network Access

IPX S@E MANAGER manual

59

IPX S@E BUILDER - Association Trunk lines/PO name/Language - Voip - Speed numbers - Service Classes - Prefixes - Suffixes - General - Least Cost Routing

Dialog Box: Numbering plan This Dialog Box lets you configure or modify the exchange Numbering Plan.

The Numbering Plan is a grid table containing the information regarding the record number, numbering interval and the type of numbering and comment field describing the range for any given family: double clicking on the type of number calls up the Dialog Box containing Tab Control Sheets with all the types of numbering available for that family. If the family calls for routing, the routing setting is displayed with a spin-type control for rapid, graphic modification.

60

IPX S@E MANAGER manual

IPX S@E BUILDER The program indicates the type of numbering associated with the defined interval. It is organized in easy-to-understand families to facilitate this phase of configuration;the breakdown is reported in the following tables:

Voice - data and CLU INDIVIDUAL LOCAL Access to groups

Generic OPERATOR Individual

ISDN (main telephone number) S0 INTERFACE ISDN (added telephone number) Access to S0 group

Single bidirectional trunk line Single incoming trunk line Single outgoing trunk line Direct Inward Dialling trunk line TRUNK LINES Trunk line single bundle General access to trunk network Acces prefix to speed number table Access to Least Cost Routing service

IPX S@E MANAGER manual

61

IPX S@E BUILDER

Single tie-lien (step+step) Access to direct Dialling Network Access to single Direct Dialling route Digital line with Q_SIG protocol NETWORKING LINES Access to single direct dialling route with Q_SIG protocol Q_SIG network remote extension Remote exchange single bundle with Q_SIG network Access to remote exchange route in Q_SIG network

NON VOICE Access to special terminations

Service prefix GENERAL USE Plug for remote Telesupervision st

th

Access prefix from 1 to 4 ANNVOC logical group

Dialog Box: Equipments This Dialog Box lets you configure or modify the exchange equipment. This box lets you configure: - number and type of equipment groups; - their position inside the subframe(s); - telephone numbers linked to the terminations for each group configured; - type of all externally-connected telephone terminals; - particular characteristics for each group ensuring correct function within the system. Configuration requires three fundamental steps: - selection of the unit subframe to be configured (this is only performed if the exchange has more than one subframe); - position the electronic groups inside the subframe in the place of the desired card slots; - configuration of the Dialog Boxes for the individual groups.

62

IPX S@E MANAGER manual

IPX S@E BUILDER

You see an image of the type of S@E exchange selected during the previous operations: "create new equipment" or "open existing equipment". The S@E 50 IPX, S@E 100 IPX, S@E 300 IPX, SAE 220, 260, 160, 80 and 32 models are shown with just one subframe, the S@E 2000 IPX, S@E 1000 IPX, S@E 500 IPX and S@E 200 IPX models are shown with more than one subframe.

IPX S@E MANAGER manual

63

IPX S@E BUILDER

64

IPX S@E MANAGER manual

IPX S@E BUILDER

If an electronic group is installed in the card slot on a subframe, this is shown by a label bearing the name of the electronic group installed, inserted in the place of the card.

In addition, beside the image of the exchange, a notepad is shown containing a summary of all the most important equipment information: terminations and range of the numbering plan. Selecting a subframe, and then an electronic group from inside this subframe, lets you view all the associated user terminations and the characteristic parameters for each.

IPX S@E MANAGER manual

65

IPX S@E BUILDER Double clicking on an electronic group inserted in a subframe card slot opens the dialog box containing its parameters. These parameters can be configured, reviewed or modified; in particular this box is broken down into two basic parts: the main part lets you configure the purely telephonicparameters for the terminations; the second part, called up by clicking "Details", lets you configure those more hardware-related electronic group parameters (i.e.: "CGQSIGA Customization" and "channel D").

In this Dialog Box the program automatically presents a list of the types that can be associated with the terminals. This ensures that all associations are correct and makes subsequent controls useless. In the same manner, to assign the telephone number for the terminals, the program offers a list of the numbers available for each type of electronic group configured under "Numbering Plan". You cannot add telephone numbers other than those automatically presented on the list. In fact, if you need to add another number which is not on the list, you must return to the Numbering Plan table. To manage the available numbers, the Dialog Box is divided into two sections: - "Available numbers" where the program displays the range of numbers available; for each range the program also presents the "Type of numbering" - "Numbers engaged" where the program displays a list of the telephone numbers which have already been assigned to physical terminations. Clicking on the telephone number for any given termination opens another box where you can configure additional details for that termination.

66

IPX S@E MANAGER manual

IPX S@E BUILDER Accessing the individual dialog boxes: - Local user - Operator console - Trunk line - Networking line There is no dialog box associated with "mixed groups" since, depending on the type of terminal, the "Local User", "Attendant Console" or "Trunk Lines" boxes will be opened. For about the group T1CAS (mixed group for USA) to follow the procedure of customizing described in the chapter "MIXED GROUPS T1CAS" Particular groups require special procedures as indicated below: - Packet Processor (connection with IP tecnology) - Dect - Voice Announcements (announcements and messages) - T1CAS (mixed group for american market) Right clicking on one of the selected groups lets you open a menu containing the following options: - Delete: deletes the group from the card slot; - Configure: lets you configure the group (the equivalent of double clicking); - Esc: lets you exit the equipment configuration section Inserting electronic groups into the different card slots into the S@E exchange subframe must comply with the position limitations imposed by the PCM bus distribution. To insert, select the group from the list of those available and then click on the empty card slot where you want to insert it. If it proves impossible to insert the group in the selected position because there is no time slot available or the group can only be inserted in a position different from the one selected the operation proves ineffective. In addition, a keyword search option is available, also shown as an icon on the tool bar.

IPX S@E MANAGER manual

67

IPX S@E BUILDER

- Search by number lets you view the data related to the desired number (if applicable) - Search by series lets you view a list of the telephone numbers belonging to the desired series (if applicable) - Search by service class lets you view the subframes, card slots and terminals associated with each extension by class (if applicable) REMOTE Remote performance can be partially achieved while equipping the subframes with the various electronic groups (i.e. selecting and positioning the groups for the different types of remote performance) and in part it can be achieved when configuring normal groups inside the remote subframes ; the latter configuration does not require any specifications other than those described for the groups inserted in the standard subframes. Each remote subframe is under a remoting group positioned in a physical subframe using a graphics procedure similar to the one used for the other groups. Double left click on the remoting group to view the remote subframe (with 4 or 12 card slots). Then, after clicking on the individual electronic groups (except mixed or remote groups) you can insert them into the subframe.

68

IPX S@E MANAGER manual

IPX S@E BUILDER

After double clicking to select the remoting group, the program presents the selected remote subframe as well as an overall view of the exchange showing the virtual situation for the groups. This virtual situation graphically represents the physical card slots; they are shown as virtually occupied by the remote groups and are, therefore, locally empty. The virtual situation depends on which physical subframes are actually equipped. In other words, even if you are configuring: - a S@E 50 IPX, S@E 100 IPX, S@E 300 IPX, SAE PLUS (32/80/160/260) exchange or a SAE LARGE 220 exchange physically fit only with the BASE SUBFRAME - a S@E 500 IPX exchange that physically fit only with the BASE and EXPANSION 3 subrames The presence of the remote PG is notified to theTDM processor (or GT in SAE exchanges not IPX) even when the subframe is not physically present. For the program, the subframes must be paired as follows: - Base / Expansion 3 Subframes; - Expansion 1 / Expansion 2 Subframes. In addition, the card slots within each subframe are paired as follows: - each pair of card slots is made up of one odd position and an adjacent even position, selected so that the odd position is lower than the even position. Therefore, even if not physically present, the remote PG is allocated within the exchange SUBFRAME using the following algorithm: - the appropriate PAIR of CARD SLOTS and PAIR of SUBFRAMES are determined according to the position of the remote group in one of the real SUBFRAMES; the four card slots defined by the two pairs are the first set of four card slots to be configured for the first set of 4 remote groups. Only the real remote Peripheral Groups are to be configured and not the remoting group; - draw the two associated PCM WIRES from the four card slots identified at point 1. These are to be remoted;

IPX S@E MANAGER manual

69

IPX S@E BUILDER - identify a pair of card slots which have not been used in the Expansion 1 / Expansion 2 subframe pair (or in the Base / Expansion 3 pair); the four card slots defined by the two pairs are the second set of four card slots to be configured for the second set of 4 remote groups; only the real remote PGs are to be configured; - in the PCM wires table, replace the PCM wires identified at point 2 for the card slots for the PG actually configured at point 3; - identify another pair of card slots which have not be used in the Expansion 1 / Expansion 2 subframe pair (or in the Base / Expansion 3 pair); the four card slots defined by the two pairs are the third set of four card slots to be configured for the third set of 4 remote groups; only the real remote PGs are to be configured; - for each remote PG configured in the PG table, the corresponding terminals are normally configured. Configuration of the remote groups are subject to the same controls provided for the configuration of local groups. To enable you to reconstruct how the exchange is equipped after inverse loading, the following information is reported in the "Subtype" field for the significant remote card slots: - CGNG703 remoting group toward the 4-CARD SLOT subframe (PSE_CGNG703_S4) - CGNG703 remoting group toward the 12-CARD SLOT subframe (PSE_CGNG703_S12) - CGNHDSL remoting group toward the 4-CARD SLOT subframe (PSE_CGNHDSL_S4) - CGNHDSL remoting group toward the 12-CARD SLOT subframe (PSE_CGNHDSL_S12) - remoting group (PSE_REMOTIZZATO). The following rules are applied to configure remoting: - If a card slot in Quaternary I is occupied, it cannot be used for remoting. - If Quaternary II or III is not found, a set of three, or a Pair or a Single free holder is set aside for remoting. - The card slots set aside for remoting but which have not been used, can be reused locally. - For each inlet into the remote subframe there must be 4 or 12 card slots set aside for remoting: those free in the base Quaternary plus those in the Quaternaries, Pairs or Singles so that you have a total of 4 or 12 card slots.

Dialog Box: Local Users Clicking on the telephone number for a local user terminal from inside a peripheral group calls up the Local User Configuration Dialog Box. You can use this box to configure some of the information for each terminal. This box is divided into four sheets: General, Details, Badge, Language.

70

IPX S@E MANAGER manual

IPX S@E BUILDER

IPX S@E MANAGER manual

71

IPX S@E BUILDER

72

IPX S@E MANAGER manual

IPX S@E BUILDER

The “Local users table” dialog box to configure the Packet Processor card is composed of five tabsheet (instead of four): General, Details, Badge, Language, IP Details.

IPX S@E MANAGER manual

73

IPX S@E BUILDER Dialog Box: Attendant Console

If you click on the telephone number of an operator console terminal while inside a peripheral group, the Attendant Console Configuration Dialog Box appears. You can use this box to configure some of the information for each terminal. This box is divided into two sheets: General, Language.

74

IPX S@E MANAGER manual

IPX S@E BUILDER

IPX S@E MANAGER manual

75

IPX S@E BUILDER Dialog Box: Trunk Line If you click on the telephone number of an urban line terminal while inside a peripheral group, the Trunk Line Configuration Dialog Box appears. You can use this box to configure some of the information for each terminal. This box is divided into three sheets: General, Details, Language.

76

IPX S@E MANAGER manual

IPX S@E BUILDER

IPX S@E MANAGER manual

77

IPX S@E BUILDER Dialog Box: Direct Dialling line If you click on the telephone number of a tie-line termination while inside a peripheral group, the Networking Line Configuration Dialog Box appears. You can use this box to configure some of the information for each terminal. This box is divided into three sheets: General, Details, Language.

78

IPX S@E MANAGER manual

IPX S@E BUILDER

IPX S@E MANAGER manual

79

IPX S@E BUILDER Dialog Box: Voice Announcements When you select the Voice Announcement group, a box appears where you can input the progression number for the voice announcement logical group and access the Voice Announcement Logical Group configuration box (by pressing the vocal boxes).

80

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: Dect Within the S@E system you can configure a maximum of: - no. 4 DECT groups in S@E IPX ENTERPRISE (S@E 200 IPX, S@E 500 IPX, S@E 1000 IPX, S@E 2000 IPX) - no. 2 DECT groups in S@E 50 IPX, S@E 100 IPX, S@E 300 IPX or SAE PLUS 32, 80, 160, 260 The DECT group is a system made up of a maximum of: - 4 8RFPI circuit boards (a base board and other expansion boards); - 32 base RFP DECT radio stations (8 for each 8RFPI circuit board); - 192 portable DECT units. DECT system customization is implemented by "remoting" a maximum of 12 16CAUn groups (corresponding to 12 x 16=192 portable DECT units) for which the DECT group acts as a remoting circuit board. The remoting groups are arranged following precise rules depending on the position of the DECT group (base circuit board). It can be inserted in any card slot where the time-slot 0 of the upper PCM wire is free. Every portable DECT unit corresponds to an S_F_MONO type terminal for a remote 16CAUn. The associated local user is, therefore, configured to the same parameters as the user with a S_F_MONO telephone plus other configurations specific for the portable DECT units. Physically the 8RFPI expansion boards are only connected to the 8RFPI base circuit board although they occupy the adjacent card slots. During customization, you must remember to leave free those card slots which will be used to support the 8RFPI expansion boards. The DECT group configuration dialog box is divided into three main sheets "Wireless", "RFP", "Details"; respectively they let you: - manage the virtual 16CAUn groups with their associated DECT wireless units; - customize the RFP radio stations; - configure the detailed parameters for the DECT system. Press "Close" to close the DECT group dialog box and save the customized data.

IPX S@E MANAGER manual

81

IPX S@E BUILDER Management of 16CAUn Virtual Groups and related wireless DECT units

The "Wireless" tab sheet on the DECT group dialog box lets you manage the 12 remote 16CAUn groups and their associated portable units. To customize the virtual groups, just press the related 12 buttons on the panel. These present the captions for the range of wireless units that can be configured and provide suggestions for the following information: - card slot and subframe virtually occupied by the group; - number of associated wireless units (if >0 the caption is highlighted in yellow). When the screen is activated, if one of the card slots selected by the DECT group is occupied by another electronic group, the button is disabled.

82

IPX S@E MANAGER manual

IPX S@E BUILDER

The dialog box used to configure a virtual group activated with the 12 buttons reflects those provided for the physical 16CAUn group with the addition of "Wireless details". To run a multiple programming of up to 192 wireless units, under "Multiple Programming" you must set the initial telephone number in the "From" box and select the final number from the list in the "To" combo-box. The Local Users dialog box automatically appears and you can customize the DECT user parameters. This section is only enabled when no portable units are configured in the DECT system. All fields are self-explanatory with the exception of the "Forward Telnumtel". This corresponds to the recognized portable network telephone number, since each portable unit can pass from one DECT system to another, thus acting as a call divert service. To delete all portable units linked to the terminals of a virtual 16CAUn group, just select that group in the combo-box under "Delete Wireless" and then press "Delete". You will be prompted to confirm this operation. To move the portable units from one remote 16CAUn to another, just select the virtual source and destination PGs in the combo-box under "Move Wireless" and then press "->".

IPX S@E MANAGER manual

83

IPX S@E BUILDER Configuration of DECT System Details

The "Details" tab sheet in the DECT group dialog box lets you set the characteristic parameters for a DECT system using special boxes. These are: - Dect Class: the acceptable range is 'A' through 'H'; - EMC: (Embedded Manufactured Code), corresponding to the DECT system manufacturer code; - PABX-ID: (PABX Identifier) unmistakably identifying one exchange from the others (each exchange has its own PABX-ID); - Paging Timeout: paging timeout for the portable units; - SAE DECT 40 Server: flag indicating whether the unit is a SAE DECT SERVER; - First service prefix: a 6-digit telephone number (roaming code, must correspond to service prefix no 77 "variable (follow me) forwarding service for other"); - Second service prefix: 6-digit telephone number (n.u.); - Third service prefix: 6-digit telephone number (n.u.); - Level 1 timer integration alarm: timeout to integrate the Upn level 1 alarm with the DECT base radio stations, expressed in tenths of a second; - First byte available: byte available for future use; - Second byte available: byte available for future use. After the settings for the EMC and PABX-ID codes have been input, the setting for the PARK box is automatically calculated (this is a read-only value). The "Restore" button lets you return the settings in the boxes on this tab sheet to those present at the moment the DECT group configuration dialog box was opened.

84

IPX S@E MANAGER manual

IPX S@E BUILDER RFP Radio Station Customization

The "RFP" tab sheet in the DECT group dialog box lets you customize the parameters for the 32 RFP base radio stations associated with the system To configure the radio stations, use the "8RFP Circuit" combo-box to select the circuit connecting the 8 RFP stations you want to customize. Then insert and/or modify the parameters present in the underlying table. For each radio station you can configure the following parameters: - PRESENT: flag indicating whether the RFP ratio station is present under customization; when set as true all the other record fields are enabled and initialized as default settings. When set as false, they are disabled. - ENROLMENT: this indicates whether enrolment (authentication of the portable unit) can be performed from the radio station; - CABLE DELAY: this field describes the group cable delay; - CIPHERING: this indicates whether or not ciphering has been activated; - BYTE1: byte available for future use; - BYTE2: byte available for future use; - BYTE3: byte available for future use. The "Restore" button lets you return the settings for all 32 RFP parameters to those assumed at the moment the DECT group configuration dialog box was opened. N. B.: to manage the DECT system, after having customized, compiled and sent the system to the S@E exchange and enrolled the portable units, after having uploaded the system you must run an inverse compilation of the system itself. If not you will lose the data for management of the DECT portable units.

IPX S@E MANAGER manual

85

IPX S@E BUILDER Sequence to follow for the DECT system customization procedure - insert the DECT PG under "Equipment" - customize "Details" in the "DECT group" dialog box - customize "RFP" in the "DECT group" dialog box - customize portable units in the "DECT group" dialog box - customize all portable telephones in the "DECT PP group" dialog box (telephone number, etc.) - customize all DECT portable units by clicking on the telephone number and accessing "portable unit details" in the "Local Users" dialog box. Insert the IPUI/IPEI for the portable unit (reading them from the unit itself, see the DECT M3 user's manual), access code and forward telnumtel (this last step must be repeated for all wireless units included in the DECT system) - system compilation and transmission - enrolment of individual wireless units (see the DECT M3 user's manual) - uploading the configuration file for the system just transmitted and subsequent inverse compilation (only after having performed this operation can you make any further modifications to the system without losing the data for the DECT wireless units, see previous note).

Dialog box: Mixed group T1CAS for USA Market The T1CAS group is an integrated system specially designed for the American market. It is made up of a maximum of three circuit boards chosen from among the following types: ALUBid, CAUa, CLG, ALUdid dial pulse and ALUdid DTMF. You must select different group types (you cannot configure the T1CAS system with two or three circuits of the same type). The remoting groups are arranged following precise rules depending on the position of the physical T1CAS board. The first virtual group (called MAIN) is always customized in the card-holder coinciding with the physical T1CAS card (X). The other two groups (called SECONDARY) are customized, again in the card holders (X,X+1) if X is odd or (X-1,X) if X is even, in a subframe calculated as follows.

Subframe for the MAIN group (position of the physical T1CAS card)

Subframe for the SECONDARY groups

Base

Expansion 1

Expansion 1

Expansion 2

Expansion 2

Expansion 1

Expansion 3

Expansion 1

The T1CAS system occupies only those card holder slots in the SAE telephone exchange which are strictly necessary for remoting the customized virtual groups. This means that if the user selects only two virtual groups (i.e. only two types of lines), only two telephone exchange card-holder slots will be remoted and the total number of access timeslots will be the sum of the modularity of the two groups.

86

IPX S@E MANAGER manual

IPX S@E BUILDER The configuration box for the T1CAS groups has two main tab sheets: "General" and "Details"; respectively, they make it possible to: - select the modularity and type of line the T1CAS must manage and configure the associated virtual groups; - configure the detailed T1CAS circuit board parameters.

-

IPX S@E MANAGER manual

87

IPX S@E BUILDER Dialog box: CAUA long distance New analog peripheral group has the following characteristics: - DTMF receivers and transmitters on board for each termination - CALLER_ID transmitters in FSK for each analog termination - it is possible activating the message lamp up to about 10 km of distance. In the basket containing the customizing peripheral groups in the equipment, the CAUa Long Distance is identified with the same acronym as the current CAUa: 16CAUa and 8CAUa. In the configuration applet, the user can customize it as a CAUa Long Distance type by clicking a check-box placed on the bottom of the mask. In this way the compatibility with previous release is assured. The updating involves: - the enabling of the user to customize the data of the "DTMF receiving levels" and the CALLER ID value (making visible the window of dedicated customization “Rec. DTMF levels”); you can leave the default DTMF level value except for specific demands; if one wants to provide all the terminations of the group with the functionality CALLER ID, defining a level and selecting the pushbutton “Set up”; - changing the AN_DECADIC lines into DUAL STANDARD lines (even if they are decadic lines to the TDM processor or GT). The transformation operation is irreversible unless the extension cancels all the modifications made on the group with the pushbutton “Cancel”.

88

IPX S@E MANAGER manual

IPX S@E BUILDER

Dialog box: Packet Processor group The Packet Processor group is a mixed group with the following functionalities: - GATEWAY (up to 30 channels for interconnection with other SAE systems provided with the same card by IP network or systems of other constructors which implemented the same protocol of dialogue chosen by SELTA), - LAN TELEPHONY (interfacing of IP telephones of the NETfon family). Packet processor is equipped with DSP circuits which allow, through expansion modules, to arrive up to a maximum of 48 contemporary communications. The available modularity of DSP is: 12, 24, 48 channels. The possibility of using the DSP resources at disposal is subject to the purchase of a VOIP adequate licence for the system. The data of the bought VOIP licence must be set up in the mask of the General Number Characteristics. The card is seen from the exchange like a Q-sig card (30 channels) and like one or more CAUN cards (from 16 each phones). The Gateway functionality is obtained by the Q-sig side while the 'LAN Telephony' one is obtained by the CAUN side. Every single "Packet processor" card can be configured in nine different ways: a)

1 card as IP NETWORKING (QSIG) or

b)

1 card as LAN TELEPHONY (CAUn) or

c)

2 cards as LAN TELEPHONY (CAUn), one of them of virtual type

d)

2 cards: one of them as IP NETWORKING (QSIG) and the other one of virtual type LAN TELEPHONY (CAUn)

e)

3 cards: one of them as IP NETWORKING (QSIG) and the other two of virtual type LAN TELEPHONY (CAUn)

f)

3 cards as LAN TELEPHONY (CAUn), two of them of virtual type

g)

4 cards as LAN TELEPHONY (CAUn), three of them of virtual type

h)

4 cards: one of them as IP NETWORKING (QSIG) and the other three of virtual type LAN TELEPHONY (CAUn)

I)

2 card as IP NETWORKING (QSIG)

The number of Packet Processor units that can be installed in a system depend on the type of exchange as described in the table below:

IPX S@E MANAGER manual

89

IPX S@E BUILDER

Model

No. Packet Pr. groups

S@E 2000 IPX

4

S@E 1000 IPX

4

S@E 500 IPX

4

S@E 200 IPX

2

S@E 300 IPX

2

S@E 100 IPX

1

S@E 50 IPX

1

Note: a) just one of the Packet Processor group equipped can be configured with GATEWAY function b) it is not foreseen its inclusion in the LEM expansion (expansion cabinet for third parts of S@E 2000) and in the REM. Every IP telephone corresponds to a NETFON_MONO or NETFON_MULTI termination type. The configuration of the associated local user will concern the same parameters of a user with SAEFON telephone, more other ones specific for the IP side. The mask for the configuration of a Packet Processor group is divided into five principal tab-sheet "IP lines", "Dsp area", "LAN Telephony area", "IP Address" and "Trace Flags"; they allow, respectively, of: - managing the Lan Telephony and QSIG virtual groups with the telephones and the lines of trunk IP associated to them; - configuring the parameters of the DSP of the card; - configuring the numbers of the ports allocated on the DSP for the voice packets (RTP) and the number of the port where the protocol MGCP transmits; - configuring statically the IP address of the Packet Processor card both for the SIP signalling and the voice packets (RTP); - configuring the parameters for the software error trace of the card.

90

IPX S@E MANAGER manual

IPX S@E BUILDER Licences management for Packet Processor function VOIP communication licence contains the following informations: - Total number of contemporary conversations: can be specified up to 192 CODEC VOIP contemporary licences (a call between 2 NETFON requires 2 CODEC licences). - Type of CODEC usefull: it is possible to use G711+G729 CODEC or use CODEC G711+G729+G723. (This data are contained in the previous licence, it is not purchasable separately). To use Packet Processor unit you have customize the following data from IPX S@E BUILDER: - set up in the General Number Characteristics table the total number of the VOIP licences bought, IPX S@E BUILDER application will make cross checker - divide the total number of CODEC DSP available resources (bought with the licence) for the "Packet processor" cards that were customized in the system in the "Number of DSP channels available" field, in the page "DSP area" of the group. IPX S@E BUILDER will check that the sum of these values does not exceed the total one admitted by the licence - in the customization of the GATEWAY section, it is necessary inserting the number of the VOIP channels reserved for Gateway functionality, this number is lower or equal to 30 (that is the maximum number of Q-sig channels) and must be lower or equal to the number of DSP channels assigned to Packet Processor card (if the unit is customized only as a Gateway the two numbers can be equal, but if it has also IP telephones the number must be lower). At last the S@E checks that the number of the CODEC licences and the customized sets correspond to the content of the "licences" file; if this control gives negative result the "Packet processor" cards are not customized. Furthermore, the system activates the QSIG supplementary services on "Packet processor" only if it is present the QSIG standard licence (differently, only the SIP standard basic call is possible).

IPX S@E MANAGER manual

91

IPX S@E BUILDER

92

IPX S@E MANAGER manual

IPX S@E BUILDER IP lines configuration The tab-sheet concerning the "IP lines" of the Packet processor group, allows the management of the IP lines associated to the groups QSIG and/or 16 Caun customized in the two sections: principal and secondary. - In the principal section configure a Caun group is possible (max 16 NETfon telephones) or, in alternative, a QSIG group to which lines of trunking are linked with SIP protocol. - In the secondary sections configure only the 16 Caun groups (48 NETfon telephones).

Configuring Packet Processor Gateway (Q-sig lines) The Packet Processor dialog box, Gateway section, is composed of two main tab-sheets: Gateway lines 1-30 and Details. Each one allows the configuration of the following data: - the "Gateway lines 1-30" tab-sheet allows the configuration of the Gateway section of the Packet Processor group; the Gateway section constitutes a type of "tie-line" interface towards IP network and the customization of the Q-sig lines which develop the service Packet Processor-Gateway is the same as standard one of the Q-sig lines; - in “Details” tab-sheet you customize the "VOIP channels number reserved for the GATEWAY function"; (the not reserved ones are used in competition for functionality Gateway and Lan Telephony)

IPX S@E MANAGER manual

93

IPX S@E BUILDER

Configuring CAUn section (IP telephones) The configuration of a CAUn with IP telephones is completely equal to that of the customization of SAEfon telephones. When an IP line is customized, besides the standard data of a SAEfon telephone, customize also the data of the "Details" page of the "local extensions" window.

94

IPX S@E MANAGER manual

IPX S@E BUILDER

IPX S@E MANAGER manual

95

IPX S@E BUILDER Configuring Dsp area The "DSP area" tab-sheet allows to set up the data concerning the DSP device.

Defining the amount of DSP usable channels (between the total ones of the bought licences) from the Packet Processor unit in the field "DSP channels number available", is important. The other fields can be left with thier default values except for specific demands.

96

IPX S@E MANAGER manual

IPX S@E BUILDER Configuring Lan Telephony area The "LAN Telephony area" tab-sheet allows to set up the data concerning the Caun section (for IP Netfon telephones).

The fields can be left with thier default values except for specific demands.

IPX S@E MANAGER manual

97

IPX S@E BUILDER Configuring IP address The "IP Address" tab-sheet allows the customization of the IP addresses necessary for the working of the Packet processor group. Statically, customize the IP address, the Subnet Mask and the Gateway of the Packet Processor unit both for the SIP signalling and the voice packets (RTP flows). The NAT section has to be customized only for specific demands, the Server DNS and Application Server parameters are for future use.

98

IPX S@E MANAGER manual

IPX S@E BUILDER Configuring Trace Flags

The configuration of this table is reserved for the laboratory staff.

IPX S@E MANAGER manual

99

IPX S@E BUILDER Configuring Modem area

In tab sheet "Modem Area" it is possible to set some modem parameters. The modems are present on the Packet Processor card, implemented by DSP on board. This applet is divided into three parts respectively dedicated to power levels, to connecting attempts and to some fields that will be implemented in future (not used at the moment).

100

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: Internal This Dialog Box lets you configure or modify the data for the terminals connected to the internal S@E network.

To configure and modify the extensions, you must access the following Dialog Boxes: - Multifunction terminal - DSS terminal - hunt groups - Pick up groups - Intercommunication user groups - Message form absent user - Known network dialling conversion - Free sequence - Financial operator service - Account Code

IPX S@E MANAGER manual

101

IPX S@E BUILDER Dialog Box: Multifunction terminal

This dialog box is composed of two tab-sheets to customize the keys from the function 1 to 12 and from 13 to 24. The profiles are general and can be assigned both to NETfon and to SAEfon telephones. If the profile is assigned to a not IP telephone, the last 8 keys are ignored (from 17 to 24). If the profile is assigned to a NETfon telephone: - NETfon 200 has 12 customizable keys; - NETfon 400 has 24 customizable keys.

102

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: DSS Terminal (K module)

This Dialog Box lets you configure or modify the configuration for the DSS terminal profiles (K module). Each DSS terminal (K module) is associated with a profile defined according to how its function keys are customized.

IPX S@E MANAGER manual

103

IPX S@E BUILDER Dialog Box: Hunt groups

Through this tab sheet it is possible configuring or modifying the composition of the hunt groups (group of extensions for the hunt groups service). In this dialog box, it is possible configure a local extension (his telephone number) in the hunt group, the application automatically presents the numbers already set up in the "Equipments" table - “Local extensions”; the list of such numbers is automatically shown for the choice. The numbers which belong to hunt groups already configured are furthermore shown, with the possibility to remove them or add some new ones, choosing among the available. To configure "tel. num. group" field, the list of the telephone numbers configured in the numbering plan as HUNT_GROUP type and S0_GROUP is automatically shown to the Operator (for the S0 groups only the S0 extensions must be presented). For the S0_GROUP (member type of the group = ISDN) the only characteristic of "distribution mode of calls" is significant while the other characteristics of the hunt group (call forward, answer mode and protection mode) are not significant. It is not possible to insert numbers different from the ones presented automatically, in this case the operator will be forced to go back to the table containing the list and add the new numbers.

104

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: Pick up groups

This Dialog Box lets you configure or modify how the composition of pick up group (group of extension for the pick up group service). It shows the numbers belonging to any previously configured Pick up groups and lets you delete them, modifing them or add new ones by selecting from among those available. In this Dialog Box, the telephone numbers available groups are those which were previously configured in the "Equipment" table for the electronic groups having local users; a list of these numbers is automatically presented for choice.

IPX S@E MANAGER manual

105

IPX S@E BUILDER Dialog Box: Intercommunication user groups

This Dialog Box lets you configure or modify Intercommunication user groups GUI (group of users for the homonymous service). The progressive numbers of intercommunicating user groups already configured, with the possibility of removing them, modifying them or adding new ones choosing among the available ones. The telephone numbers available for the composition of Intercommunication user Groups that are those completing the "TELNUM components" field are those the multifunction telephones (Saefon/ NETfon Multifunction ) previously configured in the "Equipment" table for the electronic groups having local users; a list of these numbers is automatically presented for your choice (Avail. components). Selection of the "TELNUM Key Association" is subordinate to the type of number that can be associated (extension, tie line, direct dialling route, trunk line, trunk line bundle). For each function a list of existing numbers (not previously linked to another GUI) is presented. Make your choice from this list; this list is obtained from the table associated with the type selected (Avail. Association). You cannot add telephone numbers other than those automatically presented on the list. In fact, if you need to add another number which is not on the list, you must return to the table containing the list and add the new number from this point.

106

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: Message from absent user

This Dialog Box lets you customize the Message from absent user issued.

Dialog Box: Known network dialling conversion

This Dialog Box lets you check (the table cannot be edited) the conversion for dialling known network numbers on the private QSIG network in local dialling. More specifically, for PTNX S@E extensions and local Attendant Consoles having different KNOWN NETWORK and LOCAL TELEPHONE NUMBERS, the table reports the correspondence between the two numbers.

IPX S@E MANAGER manual

107

IPX S@E BUILDER Dialog Box: Free Sequences

This dialog box allows the user to customize a free sequence that can be associated to a SAEfon and/or DSS telephone's key, through the "multifunction terminal profiles". Upper on the right there is the free sequences grid, each characterized by progressive number and free comment. On the left can be customized: - the comment to associate to the sequence so as to make it recognized in the right grid; - the list of the function code of the free sequence; - a "start sequence" name showed on the display of the telephone at the the start ot the sequence; - an "end sequence" name showed on the display of the telephone at the end of the sequence. The functions to add can be selected in three different way: - through the combo-box "Function" that contains the list of the functions; - through the combo-box "Suffixes" taht contains the list of the descriptions of all the customized suffixes in the "suffixes table". When the user choose one of the suffixes, the function keys corresponding the single digit of the suffix are added to the sequence; - though the field "Telnum": the inserted number is after divided in the single digits that composing the number.

108

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: Financial Operator

This dialog box allows the user the customization of the code sequences associated to specific functionality used by the "Financial Operator" service (for the description of the service, refer the S@E IPX "Description or Services" manual). Each function must be associated to a SAEfon and/or DSS telephone's key, through the "multifunction terminal profiles". The customizing functions of the "Financial Operator" service are the following.

IPX S@E MANAGER manual

109

IPX S@E BUILDER Acronym trunk_rcll_&_call_numtel_1

Description external/internal recall + call to a telephone's number (recorder 1) + DTMF post dialling switching

trunk_rcll_&_call_numtel_2

external/internal recall + call to a telephone's number (recorder 2) + DTMF post dialling switching

trunk_rcll_&_call_numtel_3

external/internal recall + call to a telephone's number (recorder 3) + DTMF post dialling switching

trunk_rcll_&_call_numtel_4

external/internal recall + call to a telephone's number (recorder 1) + DTMF post dialling switching

release_ext_&_retrieve_HOLD

line's connected release and retrieve from HOLD

trunk_conf

start conference

tggl_in_trunk

toggle on ISDN public network or PABX

stop_rec

stop of the recording

pause_rec

pause of the recording

start_rec

start of the recording

For each function (except the last three) is generated a sequence of signalling according the type of trunk line used: Analog, ISDN Base access, ISDN PRA, CLG, 2MBA or PABX. The sequence is choose from the software of the GT, when the key is selected, according the line connected with the inernal extension. The box "Set Financial Operator Service", when activated, shows a dialog box used for inserting the SAEPERS data for the automatic compilation of all sequences, like the following box.

110

IPX S@E MANAGER manual

IPX S@E BUILDER The user can specify the following fields: - Remote recorder access prefix: is the number that permit the access to the public network. Must be put before to the number of the recorder in the case the recorder is called through another trunk line. - Recorder 1 telephone number: telephone number that characterize the remote recorder 1 in the public network. - Recorder 2 telephone number: telephone number that characterize the remote recorder 2 in the public network. - Recorder 3 telephone number: telephone number that characterize the remote recorder 3 in the public network. - Recorder 3 telephone number: telephone number that characterize the remote recorder 4 in the public network. - Trunk exchange line release and HOLD retrieve code: to send toward analog trunk line. - Trunk exchange toggle code: to send toward analog trunk line. - Public network conference code: code to send toward the analog trunk line to activate the conference service. - Stop recording: "stop recording" code to send on trunk line (in DTMF) toward remote recording. - Recording pause: "pause recording" code to send on trunk line (in DTMF) toward remote recording. - Start recording: "start recording" code to send on trunk line (in DTMF) toward remote recording.

Dialog Box: Account Code Possibility offered to an extension to enable temporarily, up to the hung-up, any telephone through the dialling of a password with which a specific charge code, printed in the charge record, is associated (account code).

In the new table "Account code", it is possible to customize a password (composed of 6 digits) usable from the extension; to such password assign the account code number (flexible number of maximum 6 digits ), the number of temporary class the extension pass to, a comment row of maximum 10 characters to identify the extension which the account code is destined.

IPX S@E MANAGER manual

111

IPX S@E BUILDER Dialog Box: Multiproperty blocks

Through this tab-sheet it is possible configuring or modify the areas associated to every block of multiproperty, the telephone number for the night service of every area (GNS), the telephone number for the overflow of the calls towards the AC and the enabling to the automatic transfer. You can leave the default values except for specific demands. The multiproperty blocks are usable essentially for the hot line calls or call back of the trunk lines to AC (day service) or to the respective areas (night service). In this tab-sheet the program automatically presents the numbers already configured that can act as GNS (numbers defined correctly in the "equipments" table - "local extensions", if the service must be developed by a single extension, or in the table "hunt groups", if the service must be developed by a telephone group number . For the field in which the numtel for the overflow of the calls towards the AC must be set up, the program presents automatically the list of the numbers already set up in the "Equipments" table "local extensions", if the destination is a single extension, in the table "hunt groups", if the destination is a telephone group number, in the table "logical groups of vocal announcements" if the destination is an automatic answering unit or at last in the table "special terminations" if the destination is a call device of general warning call. You cannot add telephone numbers other than those automatically presented on the list. In fact, if you need to add another number which is not on the list, you must return to the table containing the list and add the new number from this point.

Dialog Box: Public network Access This Dialog Box lets you configure or modify the data involved in connections to the public network.

112

IPX S@E MANAGER manual

IPX S@E BUILDER

To configure and modify public network access you must access the following boxes: - Bundle - Forbidden trunk line number - Direct Inward dialling conversion - DID Particular Characteristics and telephone number - Timed billing plan

IPX S@E MANAGER manual

113

IPX S@E BUILDER Dialog Box: Bundle

This Dialog Box lets you configure or modify the composition of the trunk line bundles (the matching in bundles is used to define what lines, on the basis of the class of service, can be seized from an extension for the access to the public network). The bundles already set up are shown, with the possibility of removing , to modify them and to add new ones. The available telephone numbers for the composition of the bundles, which will compose the fields "Lines of the bundle", are the ones already defined in the numbering plan as SINGLE_BUNDLE type or REMOTE_BUNDLE; the list of such numbers is automatically presented for the choice. To configure bundle components the program automatically displays the numbers previously configured in the "Equipment" dialog box under "Trunk line" for the electronic groups having outgoing or bi-directional trunk lines. You cannot add telephone numbers other than those automatically presented on the list. In fact, if you need to add another number which is not on the list, you must return to the table containing the list and add the new number from this point.

114

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: Forbidden trunk line number

This Dialog Box lets you configure or modify the groups of trunk line network access numbers that cannot be dialled by internal users. This Dialog Box also lets you configure permission for access to forbidden numbers by service subclasses. The program guides you through the configuration of the forbidden trunk line numbers box before configuring the service classes. In this way, you can directly configure permission to access forbidden numbers while you are configuring the individual service classes. On the contrary, if you do not configure forbidden trunk line numbers first, you will find that the default setting disables access to all as yet undefined forbidden numbers.

IPX S@E MANAGER manual

115

IPX S@E BUILDER Dialog Box: Direct Inward dialling conversion

Through this tab sheet it is possible configuring or modifying the conversion of the incoming numbers in direct inward dialling. The conversion is executed for the lines in direct inward dialling that in the Equipments - Trunk lines table has the configured field "incoming dialling management" for the conversion.

Dialog Box: DID particular Characteristics and telephone number

Through this tab sheet it is possible configuring or modifying the number of the Attendant Console in direct inward dialling and the digits which are automatically added to the receiving of a call in direct inward dialling. This Dialog Box is called up after the Numbering Plan has been defined; the D.I.D. Attendant Console telephone number can be not defined in the Numbering Plan; if it is, never superimpose it over the internal numbering.

116

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: Timed Billing Plan

This dialog box allows the user to customize the necessary data for the timed biling plan to applicate to an outgoing tunk line. The dialog box has two main sections: - the upper section reserved to customize "default costs" to applicate to calls that aren't present in the range in the undergo grill. - the lower section reserved to customize a timed plan to applicate to calls according to the range belonging to selection.

IPX S@E MANAGER manual

117

IPX S@E BUILDER Dialog Box: Private network Access This Dialog Box lets you configure or modify the data for local or remote direct dial connections.

To configure or modify access to private lines, access the following Dialog Boxes - Route - Inhibited groups - Routings - Incoming direct dialling selection conversion - Outgoing direct dialling selection conversion - SNT Activation - VPN network characteristics - Backup on public network

118

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: Paths

Through this tab-sheet it is possible to configure or modify the composition of the local or remote direct dialling (CLG) paths (groups of single tie-line lines). In this Dialog Box the telephone numbers for the composition of the paths - that those which will complete the "TEL NUMBER PATH" fields - are those defined in the Numbering Plan as DIRECT_DIAL_PATH, or QSIG_PATH or REMOTE_PATH types of numbers; a list of these numbers is automatically presented for choice. the routes already set up are show. You can eliminate them, modify them and to add new ones. To configure Route components, the program automatically offers a list of the numbers previously configured in the "Equipment" direc dialling line table for electronic groups with TIE lines. You cannot add telephone numbers other than those automatically presented on the list. In fact, if you need to add another number which is not on the list, you must return to the table containing the list and add the new number from this point.

IPX S@E MANAGER manual

119

IPX S@E BUILDER Dialog Box: groups for forbidden nos.

This Dialog Box is used to configure or modify the Local User number groups (groups of numbers) for which access to a certain Direct Dialling Paths (CLG or QSIG) is forbidden. In this Dialog Box, the telephone numbers available for the “COMPONENTS" fields, are the numbers on the list of extension and AC telephone numbers previously configured in the "Equipment" table (local user table attendant station table); a list of these numbers is automatically presented for choice. A list of the previously configured Inhibited groups is shown. You can delete them, modify them and to add new ones. You cannot add telephone numbers other than those automatically presented on the list. In fact, if you need to add another number which is not on the list, you must return to the table containing the list and add the new number from this point.

120

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: Routings

Through this tab sheet it is possible setting up the routes which compose the direct dialling routings (CLG or QSIG) and specifying, for each paths, possible inhibitions. The routings already configured are shown, with the possibility of removing them, to modify them or adding some new. In this dialog box, to configure the composition of the routings, the application automatically presents the numbers of the paths already set up in the "paths" table and the groups for forbidden set up in the group for forbidden table. It is also shown the information concerning the numbering intervals which were associated, in the Numbering plan table, to the routing which is configuring. In all the cases above described, the list of the possible values is presented empty if they have not been set up yet the direct dialling paths or groups for forbidden, in this case the operator will be forced to go back to the table containing the list and add the new numbers.

IPX S@E MANAGER manual

121

IPX S@E BUILDER Dialog Box: Incoming direct dialling selection conversion

Through this tab sheet it is possible configuring or modifying the conversion to be made on the incoming numbers from the private network. The conversion is executed for those lines that in the table equipments - direct dialling lines have the field "type of conversion of the incoming dialling" configured for the conversion. Remember there is no relationship between the number of digits in the number being converted and the number of digits in the converted number. In other words, you can, for example, convert a 6 digit number into a 2 digit number and vice versa.

122

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: Outgoing direct dialling selection conversion

Through this tab sheet it is possible configuring or modifying the conversion to be made on the outgoing numbers to wards the private network. In addition, the program also displays a list of the previously configured outgoing direct dialling numbers. You can delete them, modify them or add new ones. In this Dialog Box the telephone numbers available for conversion-those which will make up the "NUM TO CONVERT" fields-are those for which rerouting is provided in the "Numbering Plan" table; a list of these numbers is automatically presented for choice. Remember there is no relationship between the number of digits in the number being converted and the number of digits in the converted number. In other words, you can, for example, convert a 6 digit number into a 2 digit number and vice versa.

IPX S@E MANAGER manual

123

IPX S@E BUILDER Dialog Box: DDNS Activation

This Dialog Box lets you specify the areas for which DDNS night-time service is activated using the post-prefix number dialled.

Dialog Box: VPN network characteristics / Exchange data

This Dialog Box contains a list of the causes giving rise to the ISDN RELEASE messages (DISCONNECT, RELEASE, RELEASE COMPLETE). These messages require the transmission of information on channel D in B (the ISO causes indicated have been derived from the ETS 286 standard). The default settings in this Dialog Box are those which require such transit. Therefore, as long as the current ETS 286 standard remains in force, the present table need not be modified.

124

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: VPN network characteristics / Network data / Numbering plan

This Dialog Box lets you configure, or modify, the VPN network user telephone numbers. Each number or group of numbers is assigned the number for its remote exchange (1-30).

Dialog Box: VPN network characteristics / Network data / Telephone numbers

This Dialog Box lets you configure, or modify, the characteristics of the VPN network. For example, you can link telephone numbers and timers to each of the 30 VPN network exchanges in order to set how long a VPN data link should remain active on channel D in B.

IPX S@E MANAGER manual

125

IPX S@E BUILDER Dialog Box: Backup on public network The service allows to reach a remote exchange (of Selta type or other company) routing a call on public ISDN or PSTN network as last possibility, after having tried to reach, without success because of congestion, of busy or alarm, the remote destination through the private network (IP, indifferently with protocol SIP or H.323 / Qsig and/or CLG). It is possible move towards the called exchanges, the information concerning the number and the name of the calling (this information will obviously be shown on the display of the called if provided with telephone SAEfon or NETfon). As particular case it is also possible managing directly the link between two systems directly sending the calls on ISDN or PSTN network.

For each record of this table it is possible to customize the following fields: From: first number of the range with which the number originally dialled is compared, to be able to be chained to the number contained in num_sel_urb according to the rule established by the num_cifre_acc field (the indifference condition is admitted); To: last number of the range with which the number originally dialled is compared, to be able to be chained to the number contained in num_sel_urb according to the rule established by the num_cifre_acc field (the indifference condition is admitted);

126

IPX S@E MANAGER manual

IPX S@E BUILDER Engagement mode: digits necessary to engage the trunk line to be used as backup; LCR routing digits: if the trunk line is engaged with LCR digits, it is necessary to introduce the complete number of an LCR routing in this field otherwise the field must remain empty; Digits to be sent outside: dialling digits to send towards public exchange (it is the destination number of the backup); Digits to be queued: number of digits of the original selection (from right), they must be queued to the 'digits to be sent outside'. Note. The content of the fields 'From' and 'To' must be identified in the range in the numbering plan as: - REMOTE_SUBCRIBER - REMOTE_PATH - REMOTE_BUNDLE Example: From: 799 To: 799 Engagement mode: 13 LCR routing digits: 01000 Digits to be sent outside: 0861772888 Digits to be queued: 2 Result -> after the number 0861772888, in dial out are sent the digits 99.

Dialog Box: Association Trunk lines name/Language

IPX S@E MANAGER manual

127

IPX S@E BUILDER This Dialog Box lets you configure or modify the name and language associated with each of the local users, trunk lines, tie lines or Attendant Consoles configured. The associations presented in this Dialog Box have already been configured in the following tables: "Local Users", "Trunk Line", "Networking Line" and "Attendant Console"; this dialog box has been introduced to enable a non privileged operator-without access to the listed tables-to modify these associations. In this Dialog Box the telephone numbers available for the name/language association-those completing the "TELNUM" fields-are those previously configured in the tables for networking lines, trunk lines, local users and OC; a list of these numbers is automatically presented for choice.

Dialog Box: VOIP This menu allows to configure or to modify VOIP data.

To configure or to modify VOIP data open the following dialog box: - Voip Gateway Data - Suite over IP

128

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog box: Voip Gateway data

It allows to configure the range of the Packet Processor numbering plan. The numbering plan is necessary for defining the destinations towards which send a call VOIP Gateway.

IPX S@E MANAGER manual

129

IPX S@E BUILDER

In the "Q-sig area" tab-sheet, it is possible to customize the timer (expressed in second) being equivalent to those expected for Q-sig which configure in the "Timing constant" table; it is possible to leave the default values except for specific demands.

130

IPX S@E MANAGER manual

IPX S@E BUILDER

The "SIP area" tab-sheet, regarding the SIP protocol, you can customize some data characteristic of the protocol (PTP and UDP ports) and usable lists of codec. Furthermore from the button "Configure Proxy", it is possible customizing the data for the possible Proxy SIP.

IPX S@E MANAGER manual

131

IPX S@E BUILDER

In the "Call manager" tab-sheet some timers are customized for the management of the calls. Leaving the default values, except for specification demand, is possible.

132

IPX S@E MANAGER manual

IPX S@E BUILDER

In the "WAN area" tab-sheet, it is possible to set up the general parameters for the customization of the interface V35 DTE that optionally can be equipped on the Packet processor board.

IPX S@E MANAGER manual

133

IPX S@E BUILDER

The "H.323 area" tab-sheet allows to set up the H.323 supported by the Packet protocol processor, besides the SIP protocol.

134

IPX S@E MANAGER manual

IPX S@E BUILDER

With the "NFAS signaling" tab-sheet, it is possible to inspect (but not modify) the data calculated automatically by the IPX S@E BUILDER during the customization of the NFAS group dedicated to the Packet Processor boards with gateway sections: the type of NFAS (Master or Slave), the number of the interface, the card slot and the subframe engaged by physical and virtual board. In addition customizing the following data managed by the gateway master board is possible: - UDP port of communication on LAN network among the Packet Processor cards of the same group NFAS - Interval between the diagnostics messages among the Packet Processor cards of the same group NFAS - Number of unanswered calls which set the Slave card in network alarm

IPX S@E MANAGER manual

135

IPX S@E BUILDER Dialog Box: Modem area It is possible setting up the IP address of S@E IPX and the parameters concerning the dial-in and/or the dial-out for the PPP connections.

The dial-in configuration consists in the customization of telephone number of modem group, the number of modems used for the dial-in, assignement of the modems (to use only for the dial-in: "reserved" or "pool" both for the dial-in and the dial-out), enablings under licence (RIP, Proxy ARP mutually exclusive) and the enabling to use or not the dial-in for maintenance.

136

IPX S@E MANAGER manual

IPX S@E BUILDER The configuration of a dial-out consists in the customization of the IP destination address, of the Subnet mask, of the telephone number, of the identifier of the connection, of the number of modems used for the dial-out used to make connections in multilink, of the type of dial-out, of the Rate-down (it shows if using less modem than the requested ones is necessary) and the type of assignement of the modems: Pool or Reserved (it shows as a certain number of modem must be reserved, for this dialout, on the total ones available).

Dialog box: Suite over IP

The "Suite over IP" tab-sheet allows to set up some services offered by On_Site_IpxManager software supplemented in the Packet Processor board. Through this dialog box is possible: - Establish a link via LAN from IPX Manager on PC client to the S@E IPX; - Make the SW updating from remote (only with SW version compatible with the one active on the TDM processor);

IPX S@E MANAGER manual

137

IPX S@E BUILDER - Manage a SNMP trap agent for the alarms produced by the S@E IPX on the HOST serial channel; - Call Detail Report On FTP (the charges downloaded by the HOST serial channel of the S@E, are saved on some available daily files on FTP, to be downloaded from remote with via LAN, WAN and RAS); - Make the upsetting of the HOST serial channel of the S@E towards a new serial port of the Packet Processor board (within certain limits to the charges and only if these must not be made available on FTP). The page is divided into into five main tab-sheets: "Server Suite", "Software version updating", "Charge management", "Alarm management" and "General host data".

138

IPX S@E MANAGER manual

IPX S@E BUILDER

IPX S@E MANAGER manual

139

IPX S@E BUILDER

140

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: Speed numbers

This Dialog Box lets you link any outgoing number - trunk or networking - with a speed number belonging to the speed numbers tables. Search through the available range to determine how to engage the line.

IPX S@E MANAGER manual

141

IPX S@E BUILDER Dialog Box: Service Classes

The operator can configure or modify the exchange Service Classes. The S@E system divides its functionalities according to the service classes. Each system line is associated to three service classes, through which access to the several classes offered by S@E can be allowed or denied. Up to 128 Service Classes that have been divided into logical groups with homogeneous enabling can be customized in the system. The configuration of service classes may therefore occur by selecting the tab sheet which represents the logical group and enabling or not the single functions associated to the selected logical group. When configuring the enabling subclass number (from 1 to 16) as to PUBLIC NETWORK SELECTION logical group it is possible to configure directly even the access permissions to the 64 forbidden numbers; if these ones haven't been configured yet, all access permissions to any forbidden numbers to configure are default disabled. Under the "Service Class" Form, we find keys:

142

IPX S@E MANAGER manual

IPX S@E BUILDER

· Model Classes enabling to change context; the Service Class configuration form becomes model class configuration form. · Save as model class that enables to create a new model class starting from the form configuration Service Class at time of request. The program requires the name to assign to the Model Class. · Import from model class that enables to create a new service class starting from a Model Class. The program requires name of the Model Class to import introducing for the choice the list of the already configured ones. Under the "Model Class" Form, we find keys: · Service Classes enabling to change context; the Model Class configuration form becomes Service class configuration form. · Eliminate model class enabling to cancel the current Model Class

Dialog Box: Prefixes

This Dialog Box lets you configure or modify the Service prefixes Codes. The dialog box is made up of eight sheets that can be viewed by clicking on the progressive folder number. The screen shows the total range for the service_prefix telephone numbers available and a list of those already being used.

IPX S@E MANAGER manual

143

IPX S@E BUILDER Dialog Box: Suffixes

This Dialog Box lets you configure or modify the Service Suffix codes. This dialog box is made up of three folders that can be viewed by clicking on the progressive number for the folder.

144

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: General This Dialog Box lets you configure or modify the general exchange data.

To configure and modify the general data you must access the following dialog boxes: - Language - Timing constants - General logical characteristics - General characteristics and numbers - Logical tones - Print format tables - Passwords - Service documentation peripherals - General system parameters - ISDN service characteristics - Notify mode - Licenze file loading - Alarm priority - Identifier of caller/connected subscriber elaboration

IPX S@E MANAGER manual

145

IPX S@E BUILDER Dialog Box: Language

This Dialog Box lets you establish which languages can be associated with the users. From this box you can configure 16 languages that can be associated with the individual internal or external system users. With this association the AC can display the language associated with a given line. If multiple language voice messages are managed (i.e. wake-up), the telephone number for the voice mail-box containing the pertinent message can be associated with each language.

Dialog Box: Timing constants

Through this tab sheet it is possible configuring all the timers foreseen for the various services. The dialog box has twelve pages that can be viewed using the scroll buttons.

146

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: General logical characteristics

This Dialog Box lets you configure the general logic characteristics, with a binary value, of the system.

Dialog Box: General number characteristics

This Dialog Box lets you configure the general number characteristics with not binary values.

IPX S@E MANAGER manual

147

IPX S@E BUILDER This dialog box has five pages that can be viewed using the scroll button.

Dialog Box: Logical tones

This Dialog Box lets you link each logic tone with a physical tone, a voice message or a telephone source outside the exchange.

Dialog Box: print format tables

This Dialog Box lets you configure or modify the customization data for the ES services. The following customization data are contained in this table: - the time of automatic passage from CLEARED UP or TO CLEAR UP status for any occupied rooms.

148

IPX S@E MANAGER manual

IPX S@E BUILDER - the following print parameters, common to all possible printouts: - skip page/skip 1 ¸ 9 lines at the end of a printout - length of printed page - heading - all titles for the fixed part of the dialog box of each of the following printouts: - TAX counter printout - telephone charges printout - auxiliary charges printout - wakeup printout - room status printout - room alarm printout The dialog box has seven pages that can be viewed using the special scroll button.

Dialog Box: Passwords

The operator may configure, for each S@E exchange, a password for each of the applications existing in IPX S@E MANAGER (IPX S@E BUILDER and IPX S@E VIEW) by inserting the information in the following fields: - Application: Application for which the password is configured (only IPX S@E MANAGER - IPX S@E BUILDER - IPX S@E VIEW and SAETAX passwords are significant) - Password: alphanumeric characters constituting the password - Confirm Password: alphanumeric characters constituting the password. Each introduced must be confirmed by reediting. Eight passwords are provided, ranging from 1 to 8. Such passwords are made of a number of max 9 alphanumeric characters and capital letters and are different from small letters. As to IPX S@E BUILDER and IPX S@E VIEW applications, the password introduced in the window must be digitized by the operator at connection, while as refers to the other applications, control on the password memorized on the PC with respect to that possessed by S@E is carried out automatically.

IPX S@E MANAGER manual

149

IPX S@E BUILDER Dialog Box: Service documentation peripherals

This Dialog Box lets you configure any system peripherals used to document services. The program suggests the US card slots for Printer and HOST as well as the telephone numbers for the data portion of the Remote Printer numeric telephones.

Dialog Box: General system parameters

This Dialog Box lets you configure or modify some of the general exchange parameters concerning a few peripheral groups. To configure and modify the general parameters you must access the following Dialog Boxes.

150

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: GP CAUA Characteristics

This Dialog Box lets you configure the special characteristics for the CAUA Peripheral Group.

Dialog Box : GP ALU Particular customizations

This Dialog Box lets you configure the special characteristics for the ALU Peripheral Group.

Dialog Box : GP 8CLG Particular customizations

This Dialog Box lets you configure the special characteristics for the 8CLG Peripheral Group.

IPX S@E MANAGER manual

151

IPX S@E BUILDER Dialog Box: GP Annvoc particular customizations

This Dialog Box lets you configure the special characteristics for the ANNVOC Peripheral Group.

Dialog Box: Special terminations

This Dialog Box lets you configure the telephone number for the General Alarm Call for each of the four areas of the system. The telephone numbers available in this Dialog Box are those configured for access to SPECIAL_TERMINATIONS in the Numbering Plan. You cannot add telephone numbers other than those automatically presented on the list. In fact, if you need to add another number which is not on the list, you must return to the table containing the list and add the new number from this point.

152

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: ISDN service characteristics

This Dialog Box lets you configure or modify the characteristics of the ISDN services. To configure and modify the general parameters you must access the following Dialog Boxes: - Bearer capability table - Low layer compatibility able - High loayer compatibility table - Call intercept table - Rerouting table - ETSI cause mapping - SIP cause mapping - Display character table - Causes for status transit - Level attenuation table

IPX S@E MANAGER manual

153

IPX S@E BUILDER Dialog Box: Level attenuation table

Depending to the type of terminal, this Dialog Box lets you define the levels of attenuation you want to apply to the telephone connection hooked up to the urban ISDN line. The Dialog Box is divided into separate blocks according to the type of terminal involved (Conference, Analogical and Numerical CAU, 2- and 4-wire CLG).

Dialog Box: License file loading

154

IPX S@E MANAGER manual

IPX S@E BUILDER This Dialog Box lets you load a file into the Data Base of the current system. This file configures the presence/absence of the hardware protection key and subsequent enabled licenses. The presence/absence of the hardware key is configured in this file, prepared outside the IPX S@E BUILDER application. If the key is present: the serial numbers for the twor GTs (active and spare) memorized in encrypted form and their SW service license is also configured. The program searches for the license file to load following the specified path. If the file does not exist, or if it is corrupted, the program handles the exception, issuing the appropriate message. The license file is supplied on magnetic support at the time the license is purchased and is subordinate to this purchase. The license file is a Paradox file and is copied into the db_Licenze.db file which is part of the Paradox Data Base for the current system. When the system is created the db_Licenze.db file is loaded with the default settings. Upon compiling, the fields for the db_Licenze.db file are loaded into tp_licenze.

Dialog Box: Alarm priority

Through this Dialog Box, the extension can set up the priority concerning each beginning/end documented alarm, as required by the HOST application through which it realizes the alarm documentation on PC.

IPX S@E MANAGER manual

155

IPX S@E BUILDER Dialog Box: Identifier of caller/connected subscriber elaboration

In this tab-sheet you can customize the table which is used by the SW of the TDM Processor (or GT for SAE systems not IPX) the produce the corrected calling/connected identifier (in the context of the Number Portability service) depending on whether it is sent a SETUP (outgoing engagement) or a CONNECT (answer of the called) towards the ISDN public network

Dialog Box: Least Cost Routing

156

IPX S@E MANAGER manual

IPX S@E BUILDER This Dialog Box lets you manage the Least Cost Routing service which lets you use various public telephone networks to reach the same destination; the choice of route depends on economics based on the destination you want to reach, the day and the time. To configure and modify the general data you must access the following dialog boxes: - LCR numbering plan - LCR selection conversion - Add LCR digits - LCR time table

Dialog Box: LCR numbering plan

This Dialog Box lets you configure or modify the Numbering Plan that the exchange applies for trunk routing for the LCR service. In addition you can configure all additional information regarding time slots and/or direct dialling routes associated with the various trunk routing providers. You access this table when you dial a number that has been defined as a LEAST_COST_ROUTING number in the exchange Numbering Plan.

IPX S@E MANAGER manual

157

IPX S@E BUILDER Dialog Box: LCR Dialling conversion

This Dialog Box lets you configure or modify the conversion to be made when dialling a LCR routing number (telnum taken from the LCR numbering plan table). The number of digits in the "NUMB TO CONVERT" field can be different from the number of digits in the "NUMB CONVERTED" field.

158

IPX S@E MANAGER manual

IPX S@E BUILDER Dialog Box: Add LCR digits

This Dialog Box lets you configure or modify digits to add before dialling the number. These digits identify the type of LCR routing if the "Type of Additional Conversion" field in the " LCR Numbering Plan " is equal to FIXED_ADD.

Dialog Box: LCR time table

This Dialog Box lets you configure or modify the three daily time slots which establish the scanning priority used in the "LCR Numbering Plan" table.

IPX S@E MANAGER manual

159

IPX S@E BUILDER 2.5 Compilation Submenu The Compilation submenu lets you analyze and check the configuration data you want to assigned to a new system or to the existing system currently open in the system submenu.

Accessing the individual dialog boxes: - Check correctness - Reverse compilation

Dialog Box: Check correctness

The term "compilation" is used to check the accuracy of any configuration data input and processing. Starting from these "source data" you can obtain an image of the Customization Table (TAPER) to be transferred to the S@E exchange. Obviously the TAPER tables are only generated when no incongruities are found between the data. To check the accuracy of the configuration parameters in a given data base file, a series of cross checks must be performed and a detailed report file is generated when incongruent data are found; the report file generated lets you easily find the data errors; the report for the last compilation performed for the selected system can be viewed and printed from any dialog box by clicking on the icon on the tool bar. As previously mentioned, the program operates directly on the database for the current equipment. The maximum number of errors that causes the program to automatically abort compilation is presented as default although you can modify it before starting the operation.

160

IPX S@E MANAGER manual

IPX S@E BUILDER When errors are encountered during this phase, as soon as the IPX S@E BUILDER program reaches the set maximum number of errors it aborts the operation. If this maximum number is not reached, the verification process continues until the entire PDX database has been processed. Whatever the case, the presence of even a single error will prevent the program from proceeding to build the true and proper tables calling for generation of the S@E data base image file. If the cross checks do not detect any errors, the program compiles the customization tables tp_..... The CRC setting for these data is inserted in the last two bytes for the customization tables. The calculated CRC value is saved in the Taccuino.db data base file.

The evolution and advancement of the compilation process is displayed and you can interrupt it at any time; once terminated, the completed report file is displayed with the calculated CRC setting. The TAPER image, obtained upon compilation, is recorded in the binary "systemname.TAB" file located under the same directory containing the "source" data base files. If a TAPER image file, generated during a previous compilation of the program, exists, before generating the " systemname.TAB" file, rename the existing file as " systemname.TOD". The file with the system report containing the result of the last compilation run for that system is named "Report.txt"; the report file is saved under the system directory. When the accuracy check and compilation processes are completed the program produces: - the Report.txt report file under the same directory as the compiled equipment; - the TAPER image systemname.TAB, generated from the compilation when there are no errors; - the TAPER image systemname.TOD obtained by renaming the systemname.TAB file generated during a previous compilation; - update the Taccuino.db file with the CRC calculated on the customization data.

IPX S@E MANAGER manual

161

IPX S@E BUILDER Dialog Box: Reverse compilation

The term "Reverse Compilation" is used to indicate the processing sequence that lets you draw the Paradox data base files containing the equipment "source data" starting from the image of the Customization Table (TAPER). Before you run an reverse compilation you must upload the configuration file from the S@E exchange. This process is described in a separate paragraph. When the S@E tables are being uploaded, information regarding the IPX S@E BUILDER release used to generate the tables is also transferred. When you select "Reverse Compilation", you indicate the directory and path and the program runs on the pertinent ".rit" file. It generates an equipment and allocates it in a directory having the same names as the equipment name provided by the ".rit" file. You indicate the path. The following steps are involved in reverse compilation: - verify the presence of the equipmentname.RIT file containing the binary image of the TAPER used in the reverse compilation under the current equipment directory; - check the compatibility between the current release of the IPX S@E BUILDER program and the release used to generate the equipment. Issue a message if any incompatibility between releases is found and abort the procedure; - issue a warning that the reverse compilation operations will totally overwrite any PDX files containing a source image of this equipment and request the OK to proceed. If OK is denied, the procedure is aborted;

162

IPX S@E MANAGER manual

IPX S@E BUILDER - check all CRC in the customization tables present in the equipmentname.RIT file and abort the procedure if the program calculates at least one CRC error; - translate the configuration files into PDX-format source data base files: the program reads the configuration parameters from the binary equipment image file and reconstructs the PDX data base files. These are then saved under the same directory containing the TAPER file used for reverse compilation; - abort procedure.

You can view the evolution in the processing and abort the process at any time. On the other hand, if the program release differs from the one used to generate the SAE TAPER and is, therefore, incompatible, you are notified and reverse compilation is not started. In this case no automatic recovery operations are provided. You can use the "Software release-icon association" function to manually search for a compatible version of the program and boot it. The reverse compilation process produces the following output: - PDX data base files containing the equipment in "source" format.

2.6 Communication Submenu

The TAPER in the PC can be transferred to the S@E unit and vice versa using a local serial connection or remote connection (with modem). If the PC holding the tables to be transferred is configured as a Client vs. another Server physically connected to the local or remote S@E exchange, these tables can be transferred through a LAN network.

IPX S@E MANAGER manual

163

IPX S@E BUILDER In other words, the IPX S@E MANAGER communications subsystem handles the true and proper transfer in a manner which is practically transparent to the user. Depending on the network node address and routing tables configured, this transmission can be performed under all the possible connections indicated below: - local S@E exchange, connected directly to the PC running the IPX S@E MANAGER containing the IPX S@E BUILDER program through a serial connection; - remote S@E exchange, connected by modem directly to the PC running the IPX S@E MANAGER containing the IPX S@E BUILDER program; - S@E exchange connected directly to a Server PC in a local network with the PC running the IPX S@E MANAGER containing the IPX S@E BUILDER program; - S@E exchange connected by modem to a Server PC in a local network with the PC running the IPX S@E MANAGER containing the IPX S@E BUILDER. The customization program must be able to determine whether the S@E exchange can be reached no matter which of the above means of connection is used. Transferring the tables to the S@E exchange and vice versa is only enabled after the password memorized on the S@E exchange has been checked. To execute these operations open the following dialog boxes: - From PC to S@E - From S@E to PC

Dialog Box: From Personal Computer to S@E

N.B.: the "Partial Remote " and "Total Remote" options are only valid if the Server PC is connected to the exchange by modem.

164

IPX S@E MANAGER manual

IPX S@E BUILDER Depending on the type of connection between the PC and the S@E exchange, the customization tables can be transferred from the PC to the S@E exchange in the following ways: - partial transfer - total transfer (involves the restart of the system with consequent loss of all the current communications). The system to be transferred is the current (open) system and its name appears on the Tool Bar. Before the transfer can be made from the PC to the S@E exchange, compilation of the system data base must be completed (without error). This generates, in the same system directory, the equipmentname.TAB file containing the customization data to transfer. The transfer procedure includes the following steps: SYSTEM TO TRANSFER PROMPT As previously mentioned, the configuration download, started by selecting "Communications / From PC to S@E" in the main menu, serves to transfer the currently open system. SELECT S@E TO LOAD When you have selected "Communications / From PC to S@E" in the main menu, the program automatically presents a list of the S@E units for which the routing record has been configured within the IPX S@E MANAGER (Root.db data base file); remember, the routing table lets you configure the following information for each S@E unit on the network, identified by its own logic name: - Physical communication available for connection (PC serial port or LAN) - Type of connection (local or remote) - Type of communications protocol used The communications path parameters are also configured in the same IPX S@E MANAGER Routing Dialog Box; these include: the PC serial ports, the Ethernet interface and the modem used for remote connections. Depending on which S@E exchange is to receive the configuration, connection to the PC housing the IPX S@E BUILDER program can be - local with the exchange directly connected to one of the PC serial ports (COM), - remote, with the exchange connected by modem to one of the PC serial ports (COM), - on a LAN network, with either local or remote connection of the exchange to a Communications Server PC that can be reached by Ethernet network the program automatically enables/disables the remaining options in the Dialog Box.

IPX S@E MANAGER manual

165

IPX S@E BUILDER COMMUNICATIONS PARAMETERS

The last operation before making connection with the S@E, the program lets you modify the default communications port parameters set by the IPX S@E MANAGER. In case of LAN network communication, no other parameters can be modified.

Partial transfer

166

IPX S@E MANAGER manual

IPX S@E BUILDER Partial transfer lets you make the most of the transfer time. With this transfer mode you send the S@E exchange only the differences found between the data in the system tables obtained during the last completed compilation and those in the tables saved at the last completed transfer. The partial transfer, that generally interests a limited data customization, allows the TDM Processor software (or GT for SAE not IPX ) of the S@E of storing the received data in volatile memory, of carrying out various policies of configuration database updating (in volatile memory); therefore the operator can choose among the following possibilities: - update upon zero telephone traffic - immediate update - update at a set time partial loading involves the following steps: - search for the equipmentname.TOD file in the same directory. If this file is not present, or its size differs from that of the equipmentname.TAB file, the partial load process is aborted; - request the IPX S@E MANAGER communications process for communication with the S@E exchange (a message on the screen indicates the S@E connection process); - you are prompted for the password to enable loading operations and it is compared with the one received from the S@E exchange: if they do not match you can type in a new password or exit; - verification that the requested partial load is possible by checking whether the S@E exchange configuration CRC matches the one to be transferred, saved in the Taccuino.db. If the two CRCs do not match, partial loading is not possible and a message appears on the screen; - comparison of the equipmentname.TAB file with the equipmentname.TOD file, identifying the blocks that differ. These are saved for subsequent transfer. If a partial local transfer is requested and the equipmentname.TAB and equipmentname.TOD files are the same, you are warned that loading is useless and the procedure is aborted; - if you have selected "immediate" updating of the configuration to send to the S@E exchange, the program begins to analyze the blocks to be transferred, checking whether they only contain data belonging to tables which do not affect the current exchange telephone traffic. If this check is positive, the transfer procedure includes sending the GT a message requesting "immediate partial load without interrupting current connections". If this check is negative a message appears warning you that the current telephone calls will be interrupted as a result of the transfer; you can interrupt the process at any time. If you select partial local transfer of a system at "zero traffic", the above checks are not performed. - once the preliminary checks have been made, the program proceeds to send the S@E exchange an index of the blocks identified during the previous comparison operation. Then it sends the blocks themselves and this proceeds until transfer has been completed (you are notified when transfer is complete). It is always best to distinguish the cases of partial loading where the GT performs processing which is vital for the current traffic: below is a list of these cases, depending on the type of modifications made MODIFICATIONS THAT CUT OFF THE CONNECTIONS - multiproperty blocks - numbering plan - equipment (all except service class pointers, telephone numbers for ISDN/known in PTN network and names and/or languages of the individual outfitted lines) - extensions - hunt groups

IPX S@E MANAGER manual

167

IPX S@E BUILDER - extensions - exchange absent answering groups - extensions - intercommunicating groups of users - general - general system parameters - special terminals (all fields except pointers for service classes) - general - general system parameters - special ALU customization for PG - general - general system parameters - special 8 CLG customization for PG - general - general system parameters - special AV customization for PG - general - general system parameters - ALU PG characteristics - general - service documentation peripherals - least cost routing - numbering plan MODIFICATIONS THAT CUT OFF CONNECTIONS AND REQUIRE RECUSTOMIZING THE PG - equipment - general - general system parameters - GP ALU particular customization - general - general system parameters - GP CLG particular customization - general - general system parameters - GP VA particular customization - general - general system parameters - GP CAUA characteristics MODIFICATIONS THAT SEND PROFILES TO THE SAEFON AND/OR DSS TELEPHONES AND MODIFY THE FUNCTIONS ASSOCIATED WITH THE KEYKS - extensions - multifunction terminal - extensions - DSS terminal MODIFICATIONS THAT SEND TABLES TO THE AC AND CAN SLOW DOWN AC TRAFFIC DURING RECUSTOMIZATION - speed numbers - general - language - association trunk line/po name/language - equipment (only for modification of the names and/or languages of the individual outfitted lines)

168

IPX S@E MANAGER manual

IPX S@E BUILDER Total transfer

If you select total transfer, you are immediately warned that this operation resets all charge counters; you can interrupt the process at any time. Total loading involves the following steps: - search for the equipment.000 system file for the type of telephone exchange being configured (IPGATE, IPGATE ENTERPRISE, Sae 3000 or Sae Plus). If the file does not exist, or if it is corrupted, the program handles the exception, issuing the appropriate message. - request the IPX S@E MANAGER communications for communication with the S@E exchange (a message on the screen indicates the S@E connection process); - you are prompted for the password to enable loading operations and it is compared with the one received from the S@E exchange: if they do not match you can type in a new password or exit; - comparison of the equipment.000 and equipmentname.TAB files, identifying the blocks that differ. These are saved for subsequent transfer. - once the preliminary checks have been made, the program proceeds to send the S@E exchange an index of the blocks identified during the previous comparison operation. Then it sends the blocks themselves and this proceeds until transfer has been completed (you are notified when transfer is complete).

IPX S@E MANAGER manual

169

IPX S@E BUILDER Dialog Box: From the S@E exchange to a Personal Computer

Note: the "Remote" option is only valid if the Server PC is connected to the exchange by modem. Depending on the unit selected, you can determine the type of information and communication mode. The connection can be either: -

local, with the S@E unit connected directly to a serial port on the PC;

- remote, with the telephone exchange connected to a serial port on the PC by modem; Then you can enable: - Total Transfer: input the name of the file and its path (drive, directory and subdirectory) where you wish to save the system to be uploaded; - CRC Request: when connection with the S@E unit has been completed, the program displays the CRC with the customization data for the connected S@E unit.

170

IPX S@E MANAGER manual

IPX S@E BUILDER CRC Request

After you have confirmed the parameters input in the above Dialog Box, the program: - requests the IPX S@E MANAGER communications process for communication with the S@E exchange (a message on the screen indicates the S@E connection process); - if the S@E connection is not successfully completed, a warning message appears and the procedure is aborted; - if the S@E connection is successfully completed, you are prompted for the password that enables the S@E to read the CRC and compare it with the data received from the S@E exchange: if they do not match you can type in a new password or exit; - after all preliminary checks have been completed, the program receives and displays the CRC.

IPX S@E MANAGER manual

171

IPX S@E BUILDER Total transfer

After you have confirmed the parameters input in the above Dialog Box, the program: - requests the IPX S@E MANAGER communications process for communication with the S@E exchange (a message on the screen indicates the S@E connection process); - if the S@E connection is not successfully completed, a warning message appears and the procedure is aborted; - if the S@E connection is successfully completed, you are prompted for the password enabling the S@E to read all configurations and compare them with the data received from the S@E: if they do not match you can type in a new password or exit; - once all preliminary checks have been completed, the program proceeds with receiving the blocks of data (differences) and continues until transfer is completed (you are notified when this procedure has been completed). - the program generates the nomeimpianto.RIT file. You must input the name and allocation path where the customization tables received from the S@E exchange are to be written; - abort procedure. Upon exiting, the above processing generates: - the CRC information for the customization tables saved on the S@E exchange - the nomeimpianto.RIT file containing the customization tables received in binary format from the S@E exchange.

172

IPX S@E MANAGER manual

IPX S@E BUILDER 2.7 Services Submenu

Use the Services submenu to analyze and check service data (i.e. language, search by keyword, permutator documentation and printouts) to be assigned to the new or to an existing open system using the system submenu. To execute these operations open the following dialog boxes: - Language selection - Search with key - Prints - Permutator documentation - Last report

Dialog Box: Language selection

This option lets you select the language you want to use to in the IPX S@E BUILDER menus, dialog boxes and messages. The program facilitates this selection by automatically offering a list of the languages available for IPX S@E BUILDER. The programs have been developed with the default operator interface in Italian; however, you can change the default language on-line, using the data base of languages available. Only skilled operators, equipped with compiler and linker, can add new languages to this data base through the menu prompt and only after a text-format library or resources (DLL Resources) and compilation have been prepared.

IPX S@E MANAGER manual

173

IPX S@E BUILDER The program reads the Tab_lingua_conf.db file containing a list of the languages currently available for the IPX S@E BUILDER program. You can scroll through the list and select the desired language. The Tab_lingua_conf.db is located under the Sys_ Arch system directory; if the file does not exist, or if it is corrupted, the program handles the exception, issuing the appropriate message. The operator-selected language is saved in the Def_lingua_conf.db file which is also saved in the Sys_ Arch system directory.

Dialog Box: Search with key

This option lets you make the following searches: - by telephone number: given a telephone number, the program searches the files for the information needed to identify its physical and virtual attributions on the S@E unit (termination number, slot, subrack, virtual slot, virtual subrack as well as the series (i.e. "Local User") and the group (i.e. "GP16CAU") it belongs to; - by series: given the series it belongs to (i.e. "Local Users") the program searches the files for all the telephone numbers belonging to that series, drawing all information required to identify the physical attributions of each unit. - by service class

174

IPX S@E MANAGER manual

IPX S@E BUILDER given a service class, the program searches the files for all the telephone numbers belonging to that class, each with all information required to identify the physical attributions for the unit. The shortcut search is activated on the current system. By telephone number

The program searches the data base files using the operator-selected Telephone Number as keyword and draws the information regarding: - terminal number - subframe - card slot - group The information can be displayed in fields but cannot be edited.

IPX S@E MANAGER manual

175

IPX S@E BUILDER By series

The program searches the data base files using the operator-selected family as keyword and draws all the telephone numbers belonging to this family. For each of these numbers the program also draws the: - subrack - slot - termination number - The information can be displayed in fields but cannot be edited.

176

IPX S@E MANAGER manual

IPX S@E BUILDER By service class

The program searches the data base files using the operator-selected service class as keyword and extracts all the telephone numbers belonging to this class. For each of these numbers the program also extracts the: - subrack - slot - termination number The information can be displayed in fields but cannot be edited.

IPX S@E MANAGER manual

177

IPX S@E BUILDER Dialog Box: Prints

This lets you print the Dialog Box viewed on the screen-the equivalent of a "print screen" limited to that portion of the screen bearing the Dialog Box ("Dialog Box" option)-or you can select the customization tables (Dialog Boxes) you want to print "in full" ("Archives" option). You can define the printer and the print preview function.

Dialog Box: Permutator documentation This dialog box lets you generate a notebook on the personal computer reporting the interconnections running from the groups to the permutator and from the permutator to the outside connection boxes. The incoming data are supplied by a series of information regarding the exchange side cables and couplings, network side cables and couplings, outside boxes and their location (ground floor, first floor, second floor, etc.). Thus up the file holding all this information is built and can also be printed upon request. There are two possible cases:

178

IPX S@E MANAGER manual

IPX S@E BUILDER Exchange side the number of the cable and its couplings on the S@E exchange side are displayed in relation to the linked telephone number

Permutator side the number of the cable and its couplings on the network side (extensions and external) are displayed in relation to the number of the box and its location.

IPX S@E MANAGER manual

179

IPX S@E BUILDER Dialog Box: Last report

This Dialog Box lets you display and print the last report for a system check or compilation.

180

IPX S@E MANAGER manual

IPX S@E VIEW Chapter 3 IPX S@E VIEW IPX S@E VIEW is the IPX S@E MANAGER application program that lets you maintain the S@E exchanges in real time. In detail, the main IPX S@E VIEW functions are: - INSPECT S@E EXCHANGE TELEPHONE STATUS - S@E EXCHANGE DIAGNOSTICS MANAGEMENT - SPECIAL GROUPS MANAGEMENT (VOICE ANNOUNCEMENTS, ISDN, VPN, DECT, CARD T1, FIDELIO INTERFACE) - S@E EXCHANGE UTILITIES MANAGEMENT (UPDATE PROGRAM AND COURTESY ANNOUNCEMENTS, DEBUGGING, SYSTEM DATE/TIME). The main IPX S@E BUILDER desktop menu is organized with pop-up submenus and has a tool bar containing a certain number of icons. These permit rapid access to the principle IPX S@E VIEW functions.

IPX S@E VIEW is organized in a series of submenus, each broken down into a set of dialog boxes comprising the maintenance program.

IPX S@E MANAGER manual

181

IPX S@E VIEW The submenus are: - TELEPHONE STATUS - DIAGNOSTICS - GROUP MANAGEMENT - UTILITY - COMMUNICATION - SERVICES TOOL BAR The main menu contains a Tool Bar used to quickly access menu functions; the tool bar is made up of a series of icons and some information regarding the operator-selected system. It enables you to quickly access a subgroup of functions and is context sensitive. This means that the items may or may not be enabled depending on the current working context. The tool bar is made up of the following icons: - Active TDM Processor Alarms - Active Communications - Call up ap_numtelsi table - Absolute relative pos.conversion - Language selection - Help

3. 1 Telephone status Submenu

182

IPX S@E MANAGER manual

IPX S@E VIEW In the main menu the "Telephone status" option lets you access all functions used to view and modify the telephone status of a terminal. Here you can view the status and content of the dynamic working data, view the lines excluded from telephone traffic and reinclude them or exclude others, release a terminal, check the PG acting as current master and the number of the D channel acting as current master, view the type and status of the terminals belonging to a certain peripheral group and whether they correspond to the numbers of the line. You can also view the information on the number of lines for the engaged system and display the status of any auxiliary services. Accessing the individual dialog boxes: - Inspect line telephone status - Inspect multiproperty block status - Inspect Attendant Station telephone status - Inspect conference timeslot telephone status - Inspect all lines excluded from traffic - Ins/Out of service - Forced line release - Inspection of current master for synchronism - Inspect peripheral group type - Inspect peripheral group status - Inspection traffic in progress - Inspect supplementary service

Dialog Box: Line telephone status inspection You can check the telephone status for a termination by inserting its line number or telephone number at the prompt. This calls up a dialog box with several pages showing the dynamic working data. Use the special button to update these data on line.

IPX S@E MANAGER manual

183

IPX S@E VIEW

Dialog Box: Multiproperty block telephone status inspection You can view the information for a multiproperty block and the pertinent areas by inserting its number at the prompt. This calls up a dialog box showing the content of the dynamic working data and the areas. Use the special button to update these data on line.

184

IPX S@E MANAGER manual

IPX S@E VIEW

Dialog Box: Attendant Console telephone status inspection You can view the telephone status of an Attendant Console terminal by inserting its progressive number (from 1 to 8) at the prompt. This calls up a dialog box showing the content of the dynamic working data. Use the special button to update these data on line.

IPX S@E MANAGER manual

185

IPX S@E VIEW

Dialog Box: Inspection of conference timeslot telephone status You can view the conference timeslot status and update these data on line using the special button.

186

IPX S@E MANAGER manual

IPX S@E VIEW Dialog Box: Inspection of all lines excluded from traffic You can view the list of all lines excluded from traffic. Use the special button to update these data on line.

Dialog Box: Esc/Rein of a line from telephone traffic You can exclude a line from telephone traffic or reinclude it. While reinclusion does not require any particular specifications, an ISDN channel can be excluded in two ways: - forced exclusion. If a call is currently in progress on the channel, it is immediately terminated; - scheduled exclusion. If there is no call in progress on the channel, it is immediately excluded; if a call is in progress the channel is excluded after the call has terminated. No matter what type of exclusion is selected, in all other cases exclusion is, by default, scheduled.

IPX S@E MANAGER manual

187

IPX S@E VIEW

Dialog Box: One line forced release You can force release a line.

Dialog Box: Current master inspection for synchronism You can view the information on the number of the PG acting as the current master and the number of the D channel acting as current master. Use the special button to update these data on line.

188

IPX S@E MANAGER manual

IPX S@E VIEW Dialog Box: Peripheral group type inspection You can view the type of peripheral group linked to the selected peripheral group number. Use the special button to update these data on line.

Dialog Box: Peripheral group status inspection You can view the status (free or busy) of a terminal belonging to a given peripheral group and check that it corresponds with the line numbers. Use the special button to update these data on line.

IPX S@E MANAGER manual

189

IPX S@E VIEW

Dialog Box: Current traffic inspection You can view the number of the system lines which are currently busy. Use the special button to update these data on line.

Dialog Box: Supplementary service inspection You can view the auxiliary services by inserting the service ID at the prompt. This calls up a dialog box showing the content of the dynamic working data. Use the special button to update these data on line.

190

IPX S@E MANAGER manual

IPX S@E VIEW

3. 2 Diagnostics Submenu

The item "Diagnostics" in the main menu provides all the functions needed to display the alarms on line, display the alarm files, run forced CU switchover operations, run system and peripheral group resets as well as request diagnostic tests. Accessing the individual dialog boxes: - Display alarms on-line - Controlled switching of CU and reset - Reset peripheral groups - Request to run diagnostic controls

IPX S@E MANAGER manual

191

IPX S@E VIEW Dialog Box: On line alarm display This dialog box lets you view the current alarms. Pressing a special button lets you update on line. There are several alarm boxes which will be viewed below.

192

IPX S@E MANAGER manual

IPX S@E VIEW

Dialog Box: Controlled switching of CU and reset This dialog box lets you: switchover immediately switch one of the two exchanges to zero telephone traffic reset the active exchange reset the reserve exchange reset both exchanges You are prompted to confirm any command you make. If you are resetting both CUs or resetting the active CU, the connection session is automatically terminated.

IPX S@E MANAGER manual

193

IPX S@E VIEW

Dialog Box: Peripheral Group Reset This dialog box lets you reset some of the peripheral groups comprising the exchange. You are prompted to confirm any command you make.

194

IPX S@E MANAGER manual

IPX S@E VIEW Dialog Box: Diagnostic control reset This dialog box lets you manage a series of requests for diagnostic tests:

Respectively, these functions let you - input data for the matrix connection between two time slots assigned to two lines - matrix disconnection for two time slots - run PCM terminal test - display total in/out errors on the Signal/Control bus with the peripheral - display total in/out errors on the Signal/Control bus for the specified PG - activate/deactivate a local/remote loop on a 2Mbps PG or ISDN - you can enable or disable the periodic diagnostic tests The matrix connect/disconnect operations of the time slot can interrupt the current communication. Activate/deactivate will only be accepted for the local/remote loop if there is no traffic on any of the involved PG lines. Activating the loop requires cutting off the traffic of all the involved PG lines. the lines are reincluded after the loop has been deactivated. After confirming the PCM test run, you can check the results by selecting the display alarms menu.

IPX S@E MANAGER manual

195

IPX S@E VIEW 3. 3 Group management Submenu

In the main menu, under "Diagnostics", you will find all the functions you need to manage special groups such as Voice Messages, ISDN, VPN, DECT and Fidelio interface. Accessing the individual dialog boxes: - Vocal Announcement group management - ISDN group management - VPN group management - DECT system management - T1 Card management - Fidelio interface management - Packet Processor management

196

IPX S@E MANAGER manual

IPX S@E VIEW Dialog Box: Vocal Announcement group management This box lets you manage vocal announcement groups:

The "Group and channel status inspection" box lets you view the logic status for the vocal announcement group.

The "Box status inspection/modif." dialog box lets you view, and if necessary, modify the logic status of the vocal mailboxes for the selected vocal announcement group.

IPX S@E MANAGER manual

197

IPX S@E VIEW

The "Group Excl/Reint. from traffic" lets you exclude a vocal announcemnt group from the telephone traffic and reinstate it if it was previously excluded.

The "Voice memory copy" lets you copy the sound memory from the master group to the slave group.

198

IPX S@E MANAGER manual

IPX S@E VIEW The "Master/slave status inspection" lets you save the current vocal announcement group status and configuration.

The "Master/slave exchange" lets you switch tasks between the master and slave vocal announcement group.

Dialog Box: ISDN group management This dialog box lets you manage ISDN groups.

The "D-GP channel status inspection" lets you view the channel D information associated with the group (4 D channels for GP 144_IS and S0_D4, 1 D channel for 2MB_IS)

IPX S@E MANAGER manual

199

IPX S@E VIEW

The "D channel forced exclusion from telephone traffic" lets you forcibly exclude a D channel from telephone traffic (if there are calls in progress on its B channels, they are immediately cut off).

The "D channel reserved exclusion from telephone traffic" lets you exclude a D channel from telephone traffic upon completion of any calls currently in progress on its B channels.

The "D channel introduction in telephone traffic" lets you introduce a D channel in telephone traffic.

200

IPX S@E MANAGER manual

IPX S@E VIEW The "ISDN call inspection" lets you view the information required to handle an ISDN call.

The "TEI inspection" lets you view the information for the TEI associated with a D channel.

IPX S@E MANAGER manual

201

IPX S@E VIEW Dialog Box: VPN group management This dialog box lets you manage VPN groups. It is divided into two sections: the first to view group status; the second to view VPN-related customization data reserved. Below is a list of the dialog boxes comprising the full management giving you an overview of group management. This can be integrated using the on-line Help.

Group status inspection

202

IPX S@E MANAGER manual

IPX S@E VIEW

IPX S@E MANAGER manual

203

IPX S@E VIEW

Inspection of VPN Spare customization Data

204

IPX S@E MANAGER manual

IPX S@E VIEW

IPX S@E MANAGER manual

205

IPX S@E VIEW

206

IPX S@E MANAGER manual

IPX S@E VIEW Dialog Box: DECT system management

This dialog box lets you manage the DECT system. It is divided into two sections: the first to view group and RFP status; the second to view PP DECT status. Below is a list of the dialog boxes comprising the full management giving you an overview of group management. This can be integrated using the on-line Help.

IPX S@E MANAGER manual

207

IPX S@E VIEW RFP Status and manage inspection

This dialog box has special buttons that let you make a series of choices such as "Activate", "Deactivate", "Refresh", "Vers. Sw/Hw", "Cont Stat", "Load Sw", "Sw from FP", "Mon Load", "Reset", "last IPUI", "PP1", "PP2", "PP3", "PP4".

PP DECT status inspection

208

IPX S@E MANAGER manual

IPX S@E VIEW Dialog Box: Card T1 Management

The operator can requeset inspection of the statistical error counters on the American T1circuit board. DIAL PERIPHERAL GROUP

The opertor must insert the card holder for the peripheral group to be inspected. The application will check whether it is an American T1 circuit board.If it is, a dialog box appears containig the edit boxes, updated to the error value seen at the moment the reqeset was sent out. STATISTICAL COUNTERS

IPX S@E MANAGER manual

209

IPX S@E VIEW The dialog box is divided into two section: Hour counters, displaying the errors which occurred during the last hour of operation, and day counters, showing the events over the entire day. Each section is, in turn, divided into "Current" and "Previous" respectively identifying the trend in the current counter or the previous counter.

Dialog Box: Fidelio interface management This dialog box lets you manage the Fidelio interface circuit. You can view customization data for the GT-Fidelio exchange protocol and counters indicting any errors arising during transmission. These counters can be viewed and they can also be reset.

210

IPX S@E MANAGER manual

IPX S@E VIEW

Dialog Box: Packet Processor management This dialog box lets you inspect the Packet Processor card. You can check the status of the board and manage the service of remote software updating of the TDM Processor.

IPX S@E MANAGER manual

211

IPX S@E VIEW

212

IPX S@E MANAGER manual

IPX S@E VIEW

3. 4 Utility Submenu

In the main menu, the "Utility" option lets you access all utilities functions:. Accessing the individual dialog boxes: - check software release installed - Display/modify date and time - Debugging Function

IPX S@E MANAGER manual

213

IPX S@E VIEW - Display TRACE for connected applications - Program update - Courtesy announcement - Autoloader - TDM Rate Change - Timed customization activation time - Call up ap_numtelsi table - Absolute relative pos.conversion

214

IPX S@E MANAGER manual

IPX S@E VIEW Dialog Box: Equipped software version check This dialog box lets you read the CRC for the active TDM Processor (or GT) software (main processor and controller), for the TAPER of the active TDM Processor (or GT) and for the PG software. In addition the electronic password and Serial Number are displayed for the active TDM Processor (or GT).

Below you will find an example of some of the dialog boxes.

IPX S@E MANAGER manual

215

IPX S@E VIEW

Dialog Box: Date time Display/Modific. This dialog box lets you view and modify the current clock settings for the S@E system. The date and time can also be taken from the PC.

216

IPX S@E MANAGER manual

IPX S@E VIEW Dialog Box: Debug Function This dialog box lets you view or modify the content in the TDM Processor (or GT) memory by selecting the item requested. Although this can prove to be quite useful in identifying the cause of a malfunction in the field, it is a particularly delicate operation because no controls are performed on the data input. Therefore this operation should only be performed by skilled personnel.

IPX S@E MANAGER manual

217

IPX S@E VIEW

218

IPX S@E MANAGER manual

IPX S@E VIEW

Dialog Box: TRACE display of connected application This dialog box lets you view the TDM Processor (or GT) tables containing a trace of the connections each application has made with the S@E exchange.

IPX S@E MANAGER manual

219

IPX S@E VIEW Dialog Box: Program upgrade This dialog box lets you update the software residing in the TDM Processor (or GT) flash memory by selecting the file containing the TDM Processor (or GT) program.

Dialog Box: Courtesy announcement update This dialog box lets you update the software for courtesy announcements 1 to 4 by requesting the file containing the application program for the selected announcement (only for S@E 50 IPX, S@E 100 IPX, S@E 300 IPX and SAE PLUS versions).

Dialog Box: Autoloader This dialog box lets you update the program when activated in emergency mode, without an active PC-S@E connection and while the TDM Processor (or GT) is in alarm status (only for PLUS versions).

220

IPX S@E MANAGER manual

IPX S@E VIEW Dialog Box: TDM Processor (or GT) Rate Change

This dialog box shows the following informations: - Current TDM Processor (or GT) rate - a table showing all the compatible rates with all types of HW TDM Processor (or GT) code - a check-box to set a new rate and modify , by clicking "UPDATE" button, TDM Processor (or GT) rate. The comands send to TDM Processor (or GT) from PC are the following: - Set new TDM Processor (or GT) rate - Reset active UC

Dialog Box: Time at which timed customization was activated

Such function enables the operator to program time of activation of VPN board time customization, with the possibility to carry out the RESET of the board at time of customization.

IPX S@E MANAGER manual

221

IPX S@E VIEW Dialog Box: Call up ap_numtelsi table

The user is given the possibility of downloading the "ap_numtelsi" table from TDM Processor (or GT) which contains "telephone number " " line number" associations of the exchange. This table is used to convert a request, send to TDM Processor (or GT), by a line number into a request by a telephone number.

Dialog Box: Absolute relative pos.conversion

This configuration box lets you to convert a number group position from absolute position to relative position (subframe and slot card) and viceversa. the configuration box has three main sections: - the upper section visualizes/inputs the number of absolute card slot -the lower section visualizes/inputs the subframe and the relative card slot -the right section specified the PBX type in use the two central buttons active the function of conversion. This utility is helpful when it is necessary to locate the phisical position of the card into the PBX (i.e. the number of the groups in alarm that the TDM Processor (or GT) software).

222

IPX S@E MANAGER manual

IPX S@E VIEW 3. 5 Communication Submenu

Selecting "Communication" from the main menu lets you activate or deactivate connection with the exchange. To do so select the corresponding item.

3. 6 Services Submenu

In the main menu, under "Services" you can select the language you want to use on the menus, Dialog Boxes and messages for the IPX S@E VIEW program.

IPX S@E MANAGER manual

223

IPX S@E VIEW

224

IPX S@E MANAGER manual

FAQ Chapter 4 FAQ This chapter aims at answering to the most frequently asked questions on SUITE systems. Q In case of doubled exchange, with TDM Processor (or GT)s positioned in slots 19 and 20, when starting the system which TDM Processor (or GT) starts with active TDM Processor (or GT) functions? A

The active TDM Processor (or GT) is always that positioned in slot 20 (POS UC = UC2).

Q

If a null traffic switching is required, after how long does the switching occur?

A The switching occurs after about 1 minute. If traffic isn’t null at time of request the switching doesn’t take place immediately, but only one minute after the traffic has become null. Q

If an immediate switching is required are the telephone connections going on interrupted?

A The telephone connections going on aren’t interrupted, but no new dialling is allowed for about 5 seconds Q

After a partial loading with no connection interruption, when is it possible to dial again?

A There is a time window of about 5 seconds by which it isn’t possible to carry out any activities. After such time has elapsed the exchange will return to normal working conditions. Q

After a partial loading with connection interruption, when is it possible to dial again?

A Ther’s a time window of about 15 seconds by which it isn’t possible to carry out any activities. After such time has elapsed the exchange will return to normal working conditions. Q How long does it take between exchange switch on (or in case of total transfer) and its effective functioning? A

It depends on the exchange and on its configuration. Some examples follow hereby: PLUS exchanges with max equipment: about 3 minutes. 220/500 exchanges configured with single CU and with max equipment: about 3 minutes. 220/500 exchanges configured in double and with max equipment: about 4 minutes and a half. 1000 Exchanges configured with single CU and with max equipment: about 5 minutes and a half. 1000 exchanges configured in double and with max equipment: about 6 minutes.

Q How is it possible to switch from a single to a double CU configuration? A By customizing the double CU exchange, forwarding the customization to the TDM Processor (or GT) already present in the exchange, waiting for Major alarm to trigger (on PO/US/IPX S@E VIEW), then plugging the second TDM Processor (or GT) without switching off the exchange and waiting for Major alarm switch off. Q How is it possible to switch from a double to a single CU configuration? A By customizing the single CU exchange, forwarding the customization to the already present GTS, making sure that one of the twor GTS has the red led always on, then taking it off. Q What are the passwords required after starting the connection?

IPX S@E MANAGER manual

225

FAQ A

As to IPX S@E BUILDER the default password is PAROLA1. As to IPX S@E VIEW the default password is PAROLA2. As to SAETAX the default password is PAROLA5.

Q Are the prints unreadable or does a blank sheet come out? A Make sure that the proper fonts are available on the driver of the used PC and printer. Q Once started IPX S@E MANAGER for the first time, which user and password have to be used by LOGIN? A User: ADMINISTRATOR Password: Administr Q After installing IPX S@E MANAGER ver.xx on a PC where no previous version of the application data has been installed, why, when executing IPX S@E BUILDER / IPX S@E VIEW from icon in IPX S@E MANAGER ver.xx: doesn’t IPX S@E BUILDER / IPX S@E VIEW open and is no error message displayed? Hasn’t IPX S@E BUILDER / IPX S@E VIEW been installed? A Each application belonging to IPX S@E MANAGER environment has its own installation procedure. Q After installing ver.xx on a PC where a previous version of the application data has been installed, why, when executing IPX S@E BUILDER / IPX S@E VIEW from icon in IPX S@E MANAGER ver: does IPX S@E BUILDER / IPX S@E VIEW still open in the previous version or why doesn’t IPX S@E BUILDER / IPX S@E VIEW open, but an error message is displayed instead?? A IPX S@E BUILDER / IPX S@E VIEW version connected to the icon in IPX S@E MANAGER has to be preset manually by means of “Configuration – Association icons SW versions”: make sure that IPX S@E BUILDER / IPX S@E VIEW is closed; by means of menu item “Configuration – Association icons SW versions” or corresponding icon, add and configure as PREDEFINITE version the one of IPX S@E BUILDER / IPX S@E VIEW just installed; presetting becomes active even without going out from IPX S@E MANAGER. Q What is it necessary to do when, while trying to execute IPX S@E MANAGER, the following error message is displayed?: "Com_Create(): No Socket Error". A Make sure from Win9x/NT Control Panel thet the following network components have been installed (necessary for Suite functioning): - TCP/IP protocol, commonly used to get connected to Internet and other WANs. - a network board (with relevant driver) able to physically connect the computer to the network. N.B. In case the available PC isn’t physically supplied with a network board, just install the microsoft Remote Access driver from Windows CD. Q What is it necessary to do when, while executing, IPX S@E MANAGER the following irreversible error message is displayed:"Warning: user database is corrupted. Contact supplier."

226

IPX S@E MANAGER manual

FAQ A Such signalling is displayed when the database containing the information about the users with relevant passwords has been modified from outside Suite. There might have been a try to force the protection system by means of Suite Password (for instance by overwriting the database with that available on another system).For safety reasons, the database correct status may be restored by contacting the supplier. Q Where is it possible to read the version of IPX S@E MANAGER / IPX S@E BUILDER / IPX S@E VIEW start up? A Name, version and product code of the application are reported on top, on the title bar. Q What are the minimum presettings to communicate with S@E system? A

a) In “Configuration – Routing tables – Node addresses”: Define the own local PC. Define a S@E node type for each S@E system with which it is necessary to communicate locally, remotely or LAN from the local PC. Only for LAN communication, define a PC type node for each PC, seen in network LAN from local PC, to which a S@E system is connected, with which to communicate from local PC. b) In “Configuration – routing tables – routing record”: Add a record for each application that must communicate with a given S@E system c) In “Services –SW Versions”, “General” file: for each application having to communicate with a S@E system, add the association between application version on PC and TDM Processor (or GT) SW version on S@E system. Q What is the meaning of “node”? A Each S@E system managed by the applications belonging to IPX S@E MANAGER environment and each PC from which the application data can communicate with the several S@E systems. Q What is the meaning of “Client”, “Server”, “Stand-alone”? A “Server” is a PC that can be reached in LAN, the serial ports of which are locally or remotely connected (via modem) to one or more S@E systems; not to be confused with a LAN network Server. “Client” is a PC the serial ports of which aren’t connected to any S@E system; it can communicate by means of LAN interface with a S@E system locally or remotely connected to a PC Server serial Port. “Stand-alone” is a PC that cannot be reached in LAN, the serial ports of which are locally or remotely connected (via modem) to one or more S@E systems. Q Impossible communicating with a S@E system because error message “It is necessary to configure local pc first”is displayed: where and how is the local PC to be configured? A By means of menu item Configuration – Routing tables – Node addresses” or relevant icon, in “Local PC Parameters” file. The name to give to the local PC musnt’t be given to any other node in IPX S@E MANAGER environment. The progressive number to give to the local PC must be different from that eventually already assigned to other local PCs belonging to the same LAN network, while it is independent from the numbering of the PC type nodes; on the other hand, it has no restrictions as to stand-alone PC. The address automatically given according to the progressive number introduced is used by communication protocol between IPX S@E MANAGER and S@E, which is not to be confused with the IP address with which the local PC is known in the LAN network. Exit from IPX S@E MANAGER, reopen it to make presetting active.

IPX S@E MANAGER manual

227

FAQ

Q Impossible communicating with a S@E system because no S@E system is in the list: how is it possible to create a S@E system list with which to communicate? A From each IPX S@E MANAGER application it is possible to communicate only with the S@E systems for which a record has been created by means of “Configuration – Routing Tables – Routing Record”. First of all, by means of menu item Configuration – Routing Tables – Node addresses” or relevant icon in “General” file: please add a S@E node type for each S@E system with which to communicate. The name to give to a S@E system mustn’t be already assigned to another node in IPX S@E MANAGER environment; the progressive number to assign to a S@E system has to be different from that eventually already assigned to other local, remote or LAN S@E systems LAN; on the other hand, it doesn’t depend on the numbering of PC type nodes, including the local PC. The address automatically assigned according to the inserted progressive number is used by the comunication protocol between IPX S@E MANAGER and S@E, which is not to be confused with the IP address which is meaningless in case of S@E system. Afterwards, by means of Menu item Configuration – Routing Tables – Routing Record” or relevant icon: add a record for each application that has to be communicate with a given S@E system, deciding wheter the connection has to be local, remote or LAN. The presettings are active even without exiting from IPX S@E MANAGER. Q Why is it necessary to display the status of all the IPX S@E MANAGER environment applications resulting for the S@E system with which the connection is going on? A All IPX S@E MANAGER applications can connect even at the same time to the same S@E system from different work stations and require actions that might be incompatible between one another: when possible, proper error messages are displayed , the user has to take measures before requiring actions that might endanger the activity of all the other IPX S@E MANAGER applications connected (Example: TAPER total loading from PC to S@E in IPX S@E BUILDER). Q From ver.xx it is impossible communicating with a S@E system declared compatible from the issued technical report, because the following error message is displayed “TDM Processor (or GT) SW version isn’t compatible with the present IPX S@E BUILDER / IPX S@E VIEW version”: what to do? A

By means of “Services –SW Versions”, “General” file: add the association between IPX S@E BUILDER / IPX S@E VIEW and SW TDM Processor (or GT) versions on S@E system. The pre-setting is active even without exiting from IPX S@E MANAGER. Q From ver.xx it is impossible to communicate with a S@E system declared incompatible by the issued technical report because the following error message is displayed “The TDM Processor (or GT) SW version isn’t compatible with such IPX S@E BUILDER / IPX S@E VIEW version”: what to do? A Select “Compatible version” function key to check which IPX S@E BUILDER / IPX S@E VIEW version is necessary. If an empty list is displayed consult the issued technical report regarding S@E system. Once IPX S@E BUILDER / IPX S@E VIEW compatible has been detected, close the current one and start the compatible one. Q Is it possible to start from IPX S@E MANAGER ver.xx a version previous or following IPX S@E BUILDER / IPX S@E VIEW installed on the same PC?

228

IPX S@E MANAGER manual

FAQ A Consult the issued technical reports because it can vary depending on how much the previous or following versions differ with respect to version xx. If possible, close the current IPX S@E BUILDER / IPX S@E VIEW In IPX S@E MANAGER, by means of the menu item “Configuration – Association icons SW versions ” or relevant icon: Add and make the desired IPX S@E BUILDER / IPX S@E VIEW version PREDEFINITE.By starting IPX S@E BUILDER / IPX S@E VIEW from IPX S@E MANAGER the new PREDEFINITE version will start. If it isn’t possible, close current IPX S@E BUILDER / IPX S@E VIEW / IPX S@E MANAGER Execute IPX S@E MANAGER from which it is possible to start IPX S@E BUILDER / IPX S@E VIEW of the desired version. Q Why is it impossible to communicate with a S@E different from the open system, due to the error message “The product code isn’t among those foreseen or is incompatible with the open system”? A The open system is LARGE while S@E system is PLUS or viceversa: no actions “From PC to S@E” are possible, while those “From S@E to PC” are possible. Q Why is it impossible to communicate with a S@E system of the same kind of the open system due to the error message “The product code isn’t among those foreseen or it is incompatible with the open system”? A Read the “product code” returned by S@E system, if unable to set LARGE / PLUS type consult the issued technical report regarding S@E system. By means of “Services – SW versions”, “Product code” file: check the existance and type of the product code data if unavailable, add it, if available with wrong type modify type. The presetting is active even without exiting from IPX S@E MANAGER. Q Impossible communicating with a S@E system due to error message “Routing Connection Port unavailable”: what does it mean? A The serial port from which connection to the given S@E system is expected is already used by an application external with respect to IPX S@E MANAGER: close the given application and make sure in IPX S@E MANAGER, by means of menu item “Communication – Serial Port management” or corresponding icon, that the given serial port isn’t unactive. Q Given the user telephone number, how to detect the slot of the peripheral grop it belongs to? A In IPX S@E BUILDER, select keysearch. Q How to define a service class starting from an existing model class? A After determining the service class number, select “Import from model class” from the menu. Q What is the meaning of the symbol “list with arrow” displayed on the bottom left in the tool table? A The same symbol is displayed even in the service class table and it shows that the mouse right button starts particular functions: in case of tool table, “Eliminate / Configure / Exit” on a subrack slots. Q Why must I run “Autoloader”function with an “Inactive Communication?”?

IPX S@E MANAGER manual

229

FAQ A Only for PLUS system, when during “Programme Upgrade” an irreversible error occurs and the first 64 blocks(of 1 Kbyte each) have been correctly forwarded to the given S@E system, it is possible to retry upgrade by means of Autoloader. Therefore, this is a function required to a S@E system not in normal working conditions, but only after S@E system itself has been pre-set for such emergency upgrade. Being S@E system already preset for connection, no “Start communication” has to be executed. Q Why, if “Autoloader” function is foreseen only for SAE PLUS system, selecting also SAE LARGE systems is allowed? A The listed S@Es, with which IPX S@E VIEW can communicate, are not previouslyclassified according to type LARGE / PLUS: the S@E system type is known to IPX S@E VIEW only once the communication has been started. Namely, as to “Autoloader” , the user doesn’t have to require it for SAE LARGE system, because IPX S@E VIEW doesn’t follow the normal communication starting procedure , so it doesn’t recognize the type of S@E system. Q At the end of “Courtesy announcement Upgrade” why is the communication with S@E system automatically deactivated? A At the end of each courtesy announcement loading, S@E system executes a RESET and it is possible to restart communication only once S@E has restarted working . Q What are the possible combinations of T0 and S0 terminations on 2T2Ca2Cn mixed board? A

In "tool table", "2T2Ca2Cn group" the following combinations can be programmed: - terminations from 1 to 4 of S0 plug and none of T0 plug. - terminations 1 and 2 of S0 plug and none of T0 plug. - terminations 1 and 2 of T0 plug and 2 of S0 plug. IMPORTANT! The following programming CANNOT be executed: - terminations 3 and 4 of T0 plug and 1 of S0 plug.

Q When mixed boards such as 4/2AbdCN and 2T2Ca2Cn are extracted or find themselves in in SC alarm, why does the system display alarms regarding inexistent slots or slots on which the board doesn’t insist? A This happens because, virtually, mixed boards affect also the PCM wires of such slots. Q How to customize a US Fidelio board? A US Fidelio must be programmed only as addtion to a US traditional board; furthermore it is necessary to insert the “Host” value and the slot where the US board has been plugged into table “Service Documentation Peripherals”, in field “Type of peripheral” . Q How to customize a remote printer? A

To program a remote printer, a serial printer working with XON/XOFF protocol is necessary. Then a SAEFON TK MULTI has to be programmed, and in the DSS part customize the serial port; Then connect the printer to SAEFON TK serial port and, in table "Service documentation peripherals, customize "REMOTE PRINTER" and telephone number of the SAEFON TK on which the serial port has been customized. Q How to select PO automatic exclusion?

230

IPX S@E MANAGER manual

FAQ A Management of PO automatic exclusion, subsequent to the expiry of queue management timer (local timer to the terminal itself), is selected from table “Multiproperty blocks” acting on field “PO automatic exclusion”. Q How to fix one line parking time on the Attendant Console? A The line parking time on PO is set in minutes according to the value of field “Parking time” of table “Multiproperty Blocks”. Q How to prevent a user from engaging a trunk line by means of step-by-step dialling? A To prevent a user from engaging a trunk line by means of step by step dialling it is necessary to disable it from access to the individual bundle of the trunk line to which the given number belongs . Q How to detect automatically a carrier different from TELECOM by means of LCR service? A In case of engagement of the LCR service, to detect automatically an alternative carrier differing from TELECOM and needing to dial a specific number before the trunk dialling (i.e. 1055 for INFOSTRADA), it is necessary to memorize: - the value “AGG_FISSA” in field “Conversion Addition Type” of table “LCR Numbering Plan”; - the entry pointer of table “Digit Addition” in field “Digit Addition Tab. Index” of table “LCR numbering plan”; - in the entry of “Digit Addition table”, identified by the item described before, the number to dial before the trunk dialling (i.e. 1055 for INFOSTRADA). Q How many voice boxes can be mixed and by what sequence is a mixed box reproduced? A The number of voice boxes that can be reproduced this way depends on how many “total access” boxes have been programmed in AV group. By "total access" boxes we mean those characterized as "RISPCOM", "ANVTONO" and "ANVSERV" and each one of these permanently occupies a voice channel of AV group. Each voice box programmed to be reproduced in "MIX" with another box engages two voice channels. The sum of all total access boxes (counting 2 of them if mixed with another box) must be lower than the number of available voice channels, that is to say 14. Therefore there can be max 6 mixed boxes with another box for every group. If mix with wire radio is required (instead than with a prerecorded voice box) up to 13 mixed boxes can be programmed. Reproduction of a mixed voice box with a background voice box (ANVSERV) is according the following sequence: - if the main box lasts 8 seconds the reproduction cycle is the following: - main box mixed with background (8 seconds) - background

(8 seconds)

- background

(8 seconds)

- if the main box lasts more than 8 seconds the reproduction cycle is the following: - main box mixed with background (main box duration) - background

(main box duration)

Q Is it possible to program a common answering device as destination of a direct incoming trunk line? A No (such service isn’t included in the specifications) but the problem can be solved thanks to two simple solutions:

IPX S@E MANAGER manual

231

FAQ - The first solution consists of associating "TONE SUBSTITUTION ANNOUNCEMENT" to the logical tone corresponding to a call from trunk line towards the internal extension, and this can be done by modifying the “LOGICAL TONE” programming of the exchange. - the second solution consists of programming an internal number that normally isn’t used (support number) as destination of the direct incoming call and presetting for it the forwarded call towards the box "COMMON ANSWERING DEVICE" desired. Q When new voice boxes are programmed on an AV board the previous recordings are lost, is there a way to restore them? A Restoration of the previously recorded voice boxes implies knowledge of the previous programming of the modified AV group. By means of IPX S@E VIEW maintenance program, it is possible to access to GROUP MANAGEMENT – VOICE ANNOUNCEMENT GROUP MANAGEMENT – BOX STATUS INSPECTION/MODIFICATION services; in such case it is possible to switch the STATUS of the box concerned from FREE to RECORDED. Naturally this operation is successful only if acting on the boxes that were previously effectively recorded, otherwise some boxes can be ”listened to” the content of which is totally unintelligible. Q After a programming modification to the AV group the board goes out of service (the green led is fixedly on), how can it be brought back to the traffic? A Normally (recommended procedure) AV group restoration to traffic occurs through IPX S@E VIEW by means of GROUP MANAGEMENT – VOICE ANNOUNCEMENT GROUP MANAGEMENT - EXCL/REINT GROUP FROM TRAFFIC. If IPX S@E VIEW program isn’t available, try to extract and replug the group into the slot, but such action isn’t always effective. Q How to customize courtesy announcements in a SAE PLUS system? A Connect to IPX S@E VIEW and select “UTILITY” menu, “Courtesy announcement upgrade”, choose one of the 4 possible announcements and forward file *.bin. At the end of loading TDM Processor (or GT) resets and restarts. Go on IPX S@E BUILDER and select “General”, “Logical Tones” and choose the tone to substitute with the courtesy announcement . On field “TL type” customize “physical tone”, on “TF type” “Other values”, on “Insert TF type” the time-slot value of the announcement. The time-slots of ANNOUNCEMENTS 1/ANNOUNCEMENTS 2/ ANNOUNCEMENT 3/ANNOUNCEMENTS 4 have values ranging from 12 to 15. Subtract from the value displayed on “Insert TF type” fixed value “17” and add that of the announcement (12/13/14/15). Example: Substitute file nes.bin to “Logical tones Table” , “Invitation to dial”, “Exchange 1 TL”. Send the file then, after TDM Processor (or GT) reset go to IPX S@E BUILDER on “Logical Tones”, “Invitation to dial”, “Exchange 1 TL ”, and on “Insert TF type” substitute 497 default value with 492. Q How to customize courtesy announcements in a SAE LARGE system? A Plug Courtesy Announcement board into the TDM Processor (or GT). Go to IPX S@E BUILDER and select “General”, “Logical Tones” and choose the tone to substitute with courtesy announcement. On field “TL type” customize “Physical Tone”, on“TF Type” “Other values”, on “Insert TF type” the timeslot value of the announcement . The time-slots of ANNOUNCEMENTS1/ANNOUNCEMENTS2/ ANNOUNCEMENTS3/ ANNOUNCEMENTS 4 have values ranging from 12 to 15. When the value is displayed on “Insert type of TF” insert the announcement value (12/13/14/15).

232

IPX S@E MANAGER manual