Service Manual 360 Fully Automatic Hematology Analyzer Service

Vapi, Gujarat

Web: www.merillife.com

Phone: +91 260 305 2100

Chapter 1 Foreword

1

Chapter 2 Function and operation

2

2.1 Simple operation

2

2.2 Founction Introduction

3

2.2-1 Founction Module Diagram

4

2.2-2 Connection Port of Complete Machine

7

Chapter 3 Maintenance

14

3.1

14

Routine Maintenance

3.1.1 Clean the Appearance

14

3.2 Daily Maintenace

15

3.3 Weekly Maintenance

15

3.4 Monthly Maintenace

15

3.5 Yearly Maintenance

16

3.6 Maintenance Before Transport or For the Instrument that will not be used for along time

16

Chapter4 Troubleshooting

17

Chapter5 Liquid System diagram

25

Chapter6 Mechanical Assembly

26

Chapter 1 Foreword This manual includes the information about functionality, daily operation and maintenance. To achieve the optimal performance, be sure to operate and maintain the instrument according to this manual. Functionality Operation Maintenance. In the chapter 2 There are diagrams related to express function and operation. In the chapter 3 Maintenance is mentioned. In the chapter 4 This includes Errors encountered during operation of the machine and trouble shooting.

1

Chapter 2 Function and operation 2.1 Simple Operation First: Front panel

Display

Sample Needle

Power Light Printer Cover

Aspiration Switch

2-1 Diagram Front Panel

2

Chapter 2 Function and operation Second:Operation Process 1) Test blank once,after that it will show the data for the background check .Repeat blank test till the values of all the five parameters namely WBC, RBC, HgB,PLT and MCV are within the acceptable range. 2) Once Blank is in acceptable range patient samples can be tested . Put the patient sample under the sample probe and press the start key . Ensure that bubble is not entering during the aspiration procedure . Move the sample tube along with the sample probe so that sample enters correctly into the measuring chamber. 3) Before the test is completed no other operation can be executed . After completion the needle come back to the home position and is ready for the next sample aspiration. 4) Press the key “print”. The results are printed on the thermal printer paper 5) After finishing measure sample click the right key,the menu will pop-up last bar of the menu is “shutdown” key,press this key,it will show “please shutdown power “ a few minutes later, operator can turn off the power.

3

2.2 ) Function Introduction 2.2-1. Function Module Diagram 1. Interface board

P104 bus

Motor control and

CPLD--->printer driver One-way

Printer driver

CPLD total WBC-RBC

drive unit

control unit

CPLD