TOLL FREE 1.800.342.7215 | 1.954.455.3050 | [email protected] | www.buyawg.com

YOUR SINGLE SOURCE FOR WIRE AND CABLE PRODUCTS

GROUNDING CABLES/ STATIC & GUY WIRE

TRANSMISSION & DISTRIBUTION CABLES

MULTIPLEX CABLES

LOW VOLTAGE CABLES

MEDIUM VOLTAGE CABLES

ARMORED CABLES

POWERFUL & ECONOMICAL WIRE & CABLE SOLUTIONS FOR... WINDPOWER APPLICATIONS TRANSMISSION & DISTRIBUTION

CONTROL CABLES

OPGW/FIBER OPTIC CABLES

PORTABLE POWER CABLES

SOLAR APPLICATIONS

Grounding Cables Bare Copper ........................................................................................................................101 Tinned Copper ....................................................................................................................102 Trolley Wire Copper............................................................................................................103 Copperclad Steel Wire........................................................................................................104 Tracer Wire Polyethylene Insulated Copperclad Steel ....................................................109 Static & Guy Wire Alumoclad Steel Wire.........................................................................................................105 Type M Alumoclad Steel Wire Guy Strand ......................................................................106 Galvanized Guy Wire/Static Wire.......................................................................................107 Copper Clad Ground Rods.....................................................................................................110 Bronze Ground Rod Clamps#.................................................................................................111

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

100 20180201

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

GROUNDING, STATIC & GUY WIRE Table of Contents

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Applications Used for overhead electrical distribution lines, grounding electrical substations, electrical test equipment and any other electrical system. Suitable for numerous other applications. Specifications ASTM Specifications, latest issue, as follows: Solid • ASTM B-1 Hard Drawn Temper • ASTM B-2 Medium Hard Drawn Temper • ASTM B-3 Soft Drawn Temper Stranded • ASTM B-1 Hard Drawn Temper • ASTM B-2 Medium Hard Drawn Temper • ASTM B-3 Soft Drawn Temper • ASTM B-8 - Concentric Lay, All Tempers Notes Ampacities (Amps per Conductor) are based on a 30°C ambient temperature, single conductor in air, per NEC.

Item #

SCC-01 SCC-02 SCC-03 SCC-04 SCC-05 SCC-06 SCC-07 STC-01 STC-02 STC-03 STC-04 STC-05 STC-06 STC-06a STC-07 STC-07a STC-08 STC-08a STC-09 STC-09a STC-10 STC-11 STC-12 STC-14 STC-15 STC-16 STC-17

Size AWG or KCMIL

Number of Strands

Overall Diameter (in)

Weight /MFT (lb)

Allowable Amps per Conductor

Breaking Strength – Soft (lb)

Breaking Strength – Medium (lb)

Breaking Strength – Hard (lb)

14 12 10 8 6 4 2 8 6 4 2 1 1/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 250 300 350 500 600 750 1000

Solid Solid Solid Solid Solid Solid Solid 7 7 7 7 7 7 19 7 19 7 19 7 19 19 37 37 37 61 61 61

0.064 0.081 0.102 0.129 0.162 0.204 0.258 0.146 0.184 0.232 0.292 0.332 0.373 0.373 0.419 0.419 0.470 0.470 0.528 0.528 0.575 0.630 0.681 0.813 0.893 0.998 1.152

12.43 19.77 31.43 49.98 79.46 126.40 200.90 51.0 81.1 128.9 204.9 258.4 325.8 325.8 410.9 410.9 518.1 518.1 653.3 653.3 771.9 926.3 1081.0 1544.0 1853.0 2316.0 3088.0

32 41 68 95 125 170 225 95 130 170 230 265 310 310 355 355 410 410 480 480 530 590 650 810 910 1040 1240

124.2 197.5 314 479.8 762.9 1213 1928 499 794 1320 2110 2552 3221 3221 4062 4062 5074 5074 6453 6453 7940 9160 10580 15240 18300 22890 30500

166.6 261.2 410.4 643.9 1010 1584 2450 610 959 1505 2360 2995 3705 3705 4640 4640 5970 5970 7479 7479 8952 10530 12450 17550 21060 26510 35100

213.5 336.9 529.2 826 1280 1970 3002 777 1228 1938 3050 3801 4752 4752 5926 5926 7698 7698 9617 9617 11600 13510 16060 22510 27020 34090 45030

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

101 20140110

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

Bare Copper

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Applications Used for overhead electrical distribution lines, grounding electrical substations, electrical test equipment and any other electrical system. Suitable for numerous other applications. Specifications ASTM Specifications, latest issue, as follows: Solid • ASTM B-3 Soft Drawn Temper • ASTM B-33 Tinned, Soft or Annealed Copper Wire Stranded • ASTM B-8 Concentric Lay, All Tempers Tinned • ASTM B-33 Tinned, Soft or Annealed Copper Wire Notes Ampacities (Amps per Cond.) are based on a 30°C ambient temperature, single conductor in air, per NEC.

Item #

SCC-T-01 SCC-T-02 SCC-T-03 SCC-T-04 SCC-T-05 SCC-T-06 SCC-T-07 STCC-T-01 STCC-T-02 STCC-T-03 STCC-T-04 STCC-T-05 STCC-T-06 STCC-T-06a STCC-T-07 STCC-T-07a STCC-T-08 STCC-T-08a STCC-T-09 STCC-T-09a STCC-T-10 STCC-T-11 STCC-T-12 STCC-T-14 STCC-T-15 STCC-T-16 STCC-T-17

Size AWG or KCMIL

Number of Strands

Overall Diameter (in)

Weight /MFT (lb)

Allowable Amps per Conductor

Breaking Strength – Soft (lb)

14 12 10 8 6 4 2 8 6 4 2 1 1/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 250 300 350 500 600 750 1000

Solid Solid Solid Solid Solid Solid Solid 7 7 7 7 7 7 19 7 19 7 19 7 19 19 37 37 37 61 61 61

0.064 0.081 0.102 0.129 0.162 0.204 0.258 0.146 0.184 0.232 0.292 0.332 0.373 0.373 0.419 0.419 0.470 0.470 0.528 0.528 0.575 0.630 0.681 0.813 0.893 0.998 1.152

12.43 19.77 31.43 49.98 79.46 126.4 200.9 51.0 81.1 128.9 204.9 258.4 325.8 325.8 410.9 410.9 518.1 518.1 653.3 653.3 771.9 926.3 1081.0 1544.0 1853.0 2316.0 3088.0

32 41 68 95 125 170 225 95 130 170 230 265 310 310 355 355 410 410 480 480 530 590 650 810 910 1040 1240

124.2 197.5 314 479.8 762.9 1213 1928 499 794 1320 2110 2552 3221 3221 4024 4024 5118 5074 6459 6453 7627 9160 10580 15240 18300 22890 30500

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

102 20170925

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

Tinned Copper

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Applications Trolley wire is used as an overhead power source for electric railroad locomotives, cranes, light rail transit systems, and underground mining motor cars. Construction Single conductor, solid copper, having a hard drawn temper, made in the configurations of: round, grooved, figure 8 or figure 9 deep section. Special alloys available. Specifications • ASTM B-47

Item #

Nominal Conductor Size

Round R 1/0 1/0 AWG R 2/0 2/0 AWG R 3/0 3/0 AWG R 4/0 4/0 AWG R 300 300 MCM Grooved G 2/0 2/0 AWG G 3/0 3/0 AWG G 4/0 4/0 AWG G 300 300 MCM G 350 350 MCM Figure 8 F8 1/0 1/0 AWG F8 2/0 2/0 AWG F8 4/0 4/0 AWG F8 300 300 MCM Deep Section F9 350 350 MCM F9 400 400 MCM

Overall Diameter (in)

Overall Diameter (mm)

Area Circular

Area (in2)

Area (mm2)

Weight /MFT (lb)

Weight /mile (lb)

Weight Tensile Tensile Resist. /km Strength Strength (68°(kg) (lb/in2) (kg/mm2) 20°C) /MFT (ohm)

Resist. (68°20°C) /mile (ohm)

Resist. (68°20°C) /km (ohm)

Min. Min. Break. Break. Strength Strength (lb) (kg)

.3249 .3648 .4096 .4600 .5477

8.252 9.266 10.404 11.684 13.911

105600 133100 167800 211600 30000

.0829 .1045 .1318 .1622 .2356

53.5 67.4 85.0 107.2 152.0

319.5 402.8 507.8 640.5 908.0

1687 2127 2681 3382 4794

475 599 755 953 1350

54.5 52.8 51.0 49.0 46.4

38.3 37.1 35.9 34.5 32.6

.1011 .08021 .06362 .05405 .03558

.53381 .42351 .33591 .26638 .18786

.33177 .26321 .20877 .16556 .11676

4518 5519 672 8143 10930

2049 2503 3048 3694 4958

.392 .430 .482 .574 .620

9.956 10.922 12.243 14.580 15.748

137900 167300 212000 299800 351200

.1083 .1314 .1665 .2355 .2758

69.9 84.8 107.4 151.9 177.9

417.4 506.4 641.7 907.5 1063.0

2204 2674 3388 4792 5613

621 753 955 1350 1582

50.2 48.5 46.6 44.2 42.8

35.3 34.1 32.8 31.1 30.1

.07741 .06380 .05035 .03560 .03039

.40872 .33686 .26585 .18797 .16046

.25402 .20936 .16523 .11682 .09973

5437 6373 7759 1041 11810

2466 2891 3519 4722 5357

.420x.312 .480x.352 .600x.450 .754x.570

10.7x7.9 12.2x8.9 15.2x11.1 19.2x14.5

105600 133100 211600 350100

.0829 .1045 .1662 .2750

53.5 67.4 107.2 177.4

319.7 402.9 640.5 1060.0

1687 2127 3382 5595

475 599 953 1577

51.8 50.2 46.6 42.8

36.4 35.3 32.8 30.1

.1011 .08020 .05045 .03049

.53381 .33177 .42346 .26318 .26638 .16556 .16099 .10001

4296 5248 7744 11700

1949 238 3513 5339

.707x.496 17.9x12.6 348900 .715x.522 18.9x14.0 397200

.2740 .3120

176.8 201.3

1056.0 1202.0

5576 6348

1571 1789

42.8 41.3

30.1 29.0

.03059 .02687

.16152 .14187

11730 12880

5321 5842

.10039 .08817

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

103 20140110

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

Trolley Wire Copper

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Applications Copperclad steel wire and strand combines the electrical characteristics of copper with the mechanical properties of steel. Often used for buried ground grid systems, overhead ground wire and messenger wire, it can resist mechanical damage during installation, as well as electrical damage during a fault condition. Copperclad steel has virtually no scrap value, greatly reducing the potential of theft. Construction Dead Soft Annealed (DSA) Copperclad Steel (CCS) conductors are a concentric lay-stranded construction. The CCS strands are a 40% conductivity grade of material using a low carbon steel core rendering greater flexibility to enable easier handling during installation Specifications CCS bare conductors meet or exceed the following ASTM specifications: • B-193 Standard Test Method for Resistivity of Electrical Conductor Materials • B-227 Standard Specification for Hard-Drawn Copperclad Steel Wire • B-228 Standard Specification for Concentric-Lay-Stranded Copperclad Steel Conductors • B-258 Standard Specification for Standard Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round • B-910 Standard Specification for Annealed Copperclad Steel Wire • Wires Used as Electrical Conductors Note The ampacity rating and the DC and AC resistance of the Copperclad Steel wire conductor is not equivalent to that of copper conductor. To select the correct equivalent please see the chart below. Diameter Comparison for Copper Equivalent Fusing Current for Grounding Applications Copper Clad Steel 40% DSA SIZE

Copper Product SIZE

Copper Product DIAMETER (in)

Copper Clad Steel 40% DSA DIAMETER (in)

#6 SOLID #4 SOLID 7 #9 40% DSA 7 #8 40% DSA 7 #7 40% DSA 7 #6 40% DSA 7 #5 40% DSA 19 #9 40% DSA 19 #8 40% DSA 19 #7 40% DSA 19 #6 40% DSA 19 #5 40% DSA

#6 SOLID #4 SOLID #2 7W 1 SOLID 1/0 7W 2/0 7W 3/0 7W 4/0 7W 250 12W 300 19W 400 19W 500 19W

0.162 0.204 0.292 0.289 0.368 0.414 0.464 0.552 0.574 0.629 0.726 0.813

0.162 0.204 0.343 0.385 0.433 0.486 0.546 0.572 0.642 0.721 0.810 0.910

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

104 20180201

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

Copperclad Steel Wire

Item #

Nominal CrossSectional Area (c)

Nominal CrossSectional Area (mm2)

7#9 7#8 7#7 7#6 7#5 19#9 19#8 19#7 19#6 19#5

0.07195 0.09078 0.1145 0.1443 0.1819 0.1953 0.2464 0.3107 0.3916 0.4938

46.42 58.57 73.86 93.09 117.40 126.00 159.00 200.50 252.70 318.50

Number of Wires

Diameter of Wires

Nominal Overall Diameter (in)

Maximum Resistance DC@20°C Ohm (M/ft)

Minimum Breaking Strength (lb)

Nominal Weight (lb/ft)

7 7 7 7 7 19 19 19 19 19

0.1144 0.1285 0.1443 0.162 0.1819 0.1144 0.1285 0.1443 0.162 0.1819

0.343 0.385 0.433 0.486 0.546 0.572 0.642 0.721 0.81 0.91

0.2916 0.2311 0.1833 0.1454 0.1153 0.1079 0.0855 0.0678 0.0527 0.0418

2650 3350 4220 5320 6710 6820 8610 10850 13680 17250

0.259 0.327 0.413 0.52 0.656 0.707 0.892 1.125 1.418 1.787

APPROXIMATE FUSING CURRENTS for 40% COPPER CLAD STEEL

Approximate Fusing Current (A)

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

Copperclad Steel Wire

Time to Fuse (seconds)

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 104 20180201

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc. Hallandale, Florida

Approximate Short Term Fusing Currents for 40% CCS (amps) 40% DSA Copper Clad Steel for Grounding Applications Time Cycles 19 19 19 19 19 19 7 7 7 7 (sec) No. 5 No. 6 No. 7 No. 8 No. 9 No. 4 No. 5 No. 6 No. 7 No. 8 628,917 498,762 395,542 313,684 248,767 292,171 231,706 183,754 145,726 115,568 CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL CMIL

7 No. 9 91,651 CMIL

7 No. 10 72,683 CMIL

Solid No. 2 66,365 CMIL

Solid No. 4 41,738 CMIL

Solid No. 6 26,250 CMIL

0.05 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 2

48,152 34,049 24,076 19,658 17,024 15,227 13,900 12,869 12,038 11,350 10,767 7,614

38,187 27,002 19,094 15,590 13,501 12,076 11,024 10,206 9,547 9,001 8,539 6,038

34,867 24,655 17,434 14,235 12,328 11,026 10,065 9,319 8,717 8,218 7,797 5,513

21,929 15,506 10,965 8,953 7,753 6,935 6,330 5,861 5,482 5,169 4,903 3,467

13,792 9,752 6,896 5,630 4,876 4,361 3,981 3,686 3,448 3,251 3,084 2,181

3 6 12 18 24 30 36 42 48 54 60 120

330,426 233,647 165,213 134,896 116,823 104,490 95,386 88,310 82,607 77,882 73,886 52,245

262,044 185,293 131,022 106,979 92,647 82,866 75,646 70,034 65,511 61,764 58,595 41,433

207,814 146,947 103,907 84,840 73,473 65,716 59,991 55,541 51,953 48,982 46,469 32,858

164,807 116,536 82,403 67,282 58,268 52,116 47,576 44,046 41,202 38,845 36,852 26,058

130,700 92,419 65,350 53,358 46,209 41,331 37,730 34,931 32,675 30,806 29,225 20,665

153,504 108,543 76,752 62,668 54,272 48,542 44,313 41,026 38,376 36,181 34,324 24,271

121,736 86,080 60,868 49,698 43,040 38,496 35,142 32,535 30,434 28,693 27,221 19,248

96,543 68,266 48,271 39,413 34,133 30,529 27,869 25,802 24,136 22,755 21,588 15,265

76,563 54,138 38,281 31,257 27,069 24,211 22,102 20,462 19,141 18,046 17,120 12,106

60,718 42,934 30,359 24,788 21,467 19,201 17,528 16,228 15,180 14,311 13,577 9,600

The most economical choice is to replace dead soft annealed (DSA) copper with DSA copper clad steel for grounding applications (downpole and mats). Below are a few of the major advantages: Life Equivalent to copper in corrosion resistance Fatigue Resistance Superior to annealed copper Handling Flexible and manageable like copper, yet more robust and durable than dead soft annealed copper Mechanical Higher mechanical strengths minimize physical damage during installation and service Weight Lighter than copper by 8.5% for equivalent sizes Theft Resistance Zero scrap value

COMPARISON: Approximate Short Term Fusing Currents for Copper (amps) Time Cycles 500 400 300 250 4/0 3/0 (sec) MCM MCM MCM MCM Strand Strand 500,000 400,000 300,000 250,000 211,563 167,779 CMIL CMIL CMIL CMIL CMIL CMIL .05 3 317,543 254,034 190,526 158,771 134,361 106,555 0.1 6 224,537 179,629 134,722 112,268 95,007 75,345 0.2 12 158,771 127,017 95,263 79,386 67,180 53,277 0.3 18 129,636 103,709 77,782 64,818 54,853 43,501 0.4 24 112,268 89,815 67,361 56,134 47,504 37,673 0.5 30 100,416 80,333 60,249 50,208 42,489 33,696 0.6 36 91,667 73,333 55,000 45,833 38,787 30,760 0.7 42 84,867 67,893 50,920 42,433 35,909 28,478 0.8 48 79,386 63,509 47,631 39,693 33,590 26,639 0.9 54 74,846 59,876 44,907 37,423 31,669 25,115 1 60 71,005 56,804 42,603 35,502 30,044 23,826 2 120 50,208 40,166 30,125 25,104 21,244 16,848

2/0 Strand 133,057 CMIL 84,503 59,753 42,251 34,498 29,876 26,722 24,394 22,584 21,126 19,918 18,895 13,361

1/0 Strand 105,521 CMIL 67,015 47,387 33,508 27,359 23,693 21,192 19,346 17,911 16,754 15,796 14,985 10,596

Solid No. 1 83,683 CMIL 53,146 37,580 26,573 21,697 18,790 16,806 15,342 14,204 13,287 12,527 11,884 8,403

Solid No. 2 66,365 CMIL 42,148 29,803 21,074 17,207 14,901 13,328 12,167 11,264 10,537 9,934 9,424 6,664

Solid No. 4 41,738 CMIL 026,508 18,744 13,254 10,822 9,372 8,382 7,652 7,084 6,627 6,248 5,927 4,191

Solid No. 6 26,250 CMIL 16,671 11,788 8,336 6,806 5,894 5,272 4,813 4,456 4,168 3,929 3,728 2,636

Solid No. 16,510 CMIL 10,485 7,414 5,243 4,281 3,707 3,316 3,027 2,802 2,621 2,471 2,345 1,658

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

104 20180201

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

Copperclad Steel Wire

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Description HMW polyethylene covered copperclad wire. Application Telephone and signal lines, alarm circuits, remote control, tree wire, and grounding wire. Standards ASTM-B228

Item#

PCSC-6-30 PCSC-8-30 PCSC-9-30 PCSC-10-30 PCSC-6-40 PCSC-8-40 PCSC-9-40 PCSC-10-40 PCSC-12-40

Conductor Type (High Strength Conductivity) 30% 30% 30% 30% 40% 40% 40% 40% 40%

Size AWG

Wire Diameter (in)

Breaking Strength (lb)

6 8 9 10 6 8 9 10 12

.1620 .1285 .1144 .1019 .1620 .1285 .1144 .1019 .08081

2680 1815 1491 1231 2433 1660 1368 1130 785

DC Resistance ohms/MFT @68° 1343 2136 2693 3396 1.008 1.602 2.020 2.547 4.051

Covering Thickness (in)

Appox OD PE Covered (in)

Weight /MFT (lb)

Weight /Mile (lb)

2/64 2/64 2/64 2/64 2/64 2/64 2/64 2/64 2/64

.225 .191 .177 .164 .225 .191 .177 .164 .143

80.3 51.8 41.7 33.9 80.3 51.8 41.7 33.9 22.3

424 274 220 179 424 274 220 179 118

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

109 20140921

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

Tracer Wire Polyethelene Insulated Copperclad Steel

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Application Overhead ground wire, shield wire protecting transmission lines against lightning damage. Construction Alumoclad steel wire and strand is used by power utilities as well as formed wire and optical ground wire manufacturers. alumoclad steel wire outlasts other options by as much as 200% in corrosive environments, significantly lowering maintenance and replacement costs. When compared to solid aluminum wire, alumoclad steel wire offers tremendous savings. Alumoclad steel wire overhead ground wire has excellent corrosion resistance. Its strength and conductivity remain unchanged in any atmosphere where aluminum is satisfactory, especially those known to be corrosive from industrial or atmospheric conditions. This assurance against corrosion is obtained through the application of a thick covering of pure aluminum which provides a substantial barrier of protective metal. The minimum cladding thickness of alumoclad steel wire is 10% of the radius of the wire. the cladding has a continuous, strong metallic bond to the steel core that will not crack or flake. Alumoclad steel wire also provides strength greater than or equal to other overhead ground wires. For commonly used wire sizes, the tensile strength of the individual wire can approach 200,000 pounds per square inch. When used in a strand for overhead ground wire, this high strength permits greater span lengths, less sag and heavier loads under storm loading conditions. Directly related to strength and sag performance is the lighter weight of alumoclad steel wire. Due to its thick cladding of aluminum, alumoclad steel wire is 15% lighter that a steel strand of equivalent size. This lighter weight, combined with high strength, permits alumoclad steel wire to be installed to the same sags as steel with correspondingly lower tensions and tower stresses on the towers or supporting structures. Specifications • B415 Standard Specification for Hard-Drawn Aluminum-Clad Steel Wire • B416 Standard Specification for Concentric-Lay-Stranded Aluminum-Clad Steel Conductors

Item #

ALUM-01 ALUM-02 ALUM-03 ALUM-04 ALUM-05 ALUM-06 ALUM-07 ALUM-08 ALUM-09 ALUM-10 ALUM-11 ALUM-12 ALUM-13 ALUM-14 ALUM-15 ALUM-16 ALUM-17 ALUM-18

No. and Size of Wire

Nominal Diameter (in)

Nominal Diameter (mm)

Breaking Load (lb)

Breaking Load (kg)

Weight /MFT (lb)

Weight /km (kg)

37 #5 37 #6 37 #7 37 #8 37 #9 37 #10 19 #5 19 #6 19 #7 19 #8 19 #9 19 #10 7 #5 7 #6 7 #7 7 #8 7 #9 7 #10

1.270 1.130 1.010 .899 .801 .713 .910 .810 .721 .642 .572 .509 .546 .486 .433 .385 .343 .306

32.30 28.80 25.70 22.90 20.30 17.90 23.10 20.60 18.30 16.30 14.50 12.90 13.90 12.40 11.00 9.78 8.71 7.76

142800 120200 100700 84200 66770 52950 73350 61700 51730 43240 34290 27190 27030 22730 19060 15930 12630 10020

647900 54500 45690 38190 30290 24020 33270 27990 23460 19610 15550 15550 12260 10310 8645 7226 5729 4545

2802 2222 1762 1398 1108 879 1430 1134 899.5 713.5 565.8 448.7 524.9 416.3 330.0 261.8 207.6 164.7

4170 3307 2623 2080 1649 1308 2129 1688 1339 1062 842.0 667.7 781.1 619.5 491.1 389.6 308.9 245.1

Resistance Resistance /MFT /km @ 68°F @ 20°F (ohm) (ohm) .04247 .05356 .06754 .08516 .1074 .1354 .08224 .1037 .1308 .1649 .2079 .2622 .2264 .2803 .3535 .4458 .5621 .7088

.1394 .1757 .2216 .2794 .3523 .4443 .2698 .3402 .4290 .5409 .6821 .8601 .7426 .9198 1.160 1.463 1.844 2.325

Area (in2)

Area (mm2)

.96152 .76264 .60509 .47984 .38032 .30174 .49438 .39163 .31073 .24641 .19530 .15495 .18193 .14435 .11448 .09077 .07198 .05708

620.60 492.20 390.30 309.50 245.50 194.70 318.70 252.70 200.40 158.90 126.10 99.96 117.40 93.10 73.87 58.56 46.44 36.83

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

105 20140924

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

Alumoclad Steel Wire

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

Alumoclad Steel Wire Item #

ALUM-19 ALUM-20 ALUM-21 ALUM-22 ALUM-23 ALUM-24 ALUM-25 ALUM-26 ALUM-27 ALUM-28 ALUM-29 ALUM-30 ALUM-31 ALUM-32 ALUM-33 ALUM-34 ALUM-35

No. and Size of Wire

Nominal Diameter (in)

Nominal Diameter (mm)

Breaking Load (lb)

Breaking Load (kg)

Weight /MFT (lb)

Weight /km (kg)

7 #11 7 #12 3 #5 3 #6 3 #7 3 #8 3 #9 3 #10 #4 #5 #6 #7 #8 #9 #10 #11 #12

.272 .242 .392 .349 .311 .277 .247 .220 .2043 .1819 .1620 .1443 .1285 .1144 .1019 .0907 .0808

6.91 6.16 9.96 8.87 7.90 7.03 6.26 5.58 5.19 4.62 4.12 3.67 3.26 2.91 2.59 2.30 2.05

7945 6301 12230 10280 8621 72060 5715 4532 5081 4290 3608 3025 2529 2005 1590 1261 1000

3604 2858 5547 4663 3910 3269 2592 2056 2305 1946 1637 1372 1147 909 721 572 454

130.6 103.6 224.5 178.1 141.2 112.0 888.1 704.3 936.3 742.5 588.8 466.9 370.3 293.7 232.9 184.7 146.5

194.4 154.2 334.1 265.0 201.1 166.7 132.2 104.8 139.3 110.5 87.62 69.48 55.11 43.71 34.66 27.49 21.80

Resistance Resistance /MFT /km @ 68°F @ 20°F (ohm) (ohm) .8938 2.932 1.127 3.697 .5177 1.699 .6528 2.142 .8232 2.701 1.038 3.406 1.309 4.294 1.651 5.415 1.222 4.009 1.541 5.056 1.943 6.375 2.450 8.038 3.089 10.13 3.986 12.78 4.912 16.12 6.194 20.32 7.811 25.63

Area (in2)

Area (mm2)

.04527 .03590 .07796 .06185 .04905 .03890 .03085 .02446 .03278 .02599 .02062 .01635 .01297 .01028 .00816 .00647 .00513

29.21 23.16 50.32 39.90 31.65 25.10 19.90 15.78 21.15 16.77 13.30 10.55 8.368 6.632 5.261 4.172 3.309

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 105 20140924

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Application Power lines, telephone lines, railway signals, communication lines, towers, masts. Construction Type M alumoclad guy strand is an economical, corrosion resistant buying material for use on overhead line structures. The thick cladding of aluminum on each wire protects the high-strength steel core from rusting and subsequent loss of strength. Costly maintenance is eliminated and the original safety factor of the guy is maintained throughout the life of the line. The alumoclad steel wire used to make Type M guy strand is unique in that the aluminum cladding thickness is guaranteed to be no less than 10% of the wire radius. Thus, a thick corrosion barrier that is pure aluminum not zinc or and iron-aluminum alloy protects the steel core. Another important feature of any coated or clad wire is the bond between the coating material and the base metal. In the case of alumoclad steel wire, the aluminum cladding and steel core are joined by a continuous ductile weld. This assures against cracking or separating of the protective aluminum form the steel core. Type M alumoclad steel wire guy strand is easily handled and installed. It weighs less than any of the other high-strength guying materials. Specifications • A474 Standard Specification for Aluminum-Coated Steel Wire Strand • B415 Standard Specification for Hard-Drawn Aluminum-Clad Steel Wire • B416 Standard Specification for Concentric-Lay-Stranded Aluminumclad Steel Conductors

Item #

AGM-1 AGM-2 AGM-3 AGM-4 AGM-5 AGM-6 AGM-7 AGM-8 AGM-9 AGM-10 AGM-11 AGM-12 AGM-13 AGM-14 AGM-15 AGM-16 AGM-17 AGM-18 AGM-19

Designation

Construction Nos. (in)

AWG (Equiv.)

Stranded Diameter (in)

Cross Section (in2)

Breaking Load (lb)

Weight /MFT (lb)

4 MG3 5 MG3 6 MG 6.6 MG 7 MG3 8 MG 5/16 in. MG3 10 MG 5/16 in. MG 11.5 MG 12.5 MG 3/8 in. MG 14 MG 16 MG 18 MG 7/16 in. MG 20 MG 1/2 in. MG 25 MG

3/0.102 3/0.114 7/0.081 7/0.083 3/0.128 7/0.191 3/0.141 7/0.102 7/0.104 7/0.110 7/0.114 7/0.121 7/0.121 7/0.128 7/0.139 7/0.145 7/0.148 7/0.165 7/0.173

3/10 AWG 3/9 AWG 7/12 AWG N/A 3/8 AWG 7/11 AWG 3/7 AWG 7/10 AWG N/A N/A 7/9 AWG N/A N/A 7/8 AWG N/A 7/7 AWG N/A N/A N/A

0.220 0.247 0.242 0.249 0.277 0.272 5/16 0.306 5/16 0.330 0.343 3/8 0.363 0.386 0.417 7/16 0.444 1/2 0.519

0.0245 0.0306 0.0361 0.0379 0.0386 0.0455 0.0495 0.0572 0.0595 0.0665 0.0714 0.0792 0.0805 0.0901 0.1062 0.1156 0.1204 0.1497 0.1645

4,500 5,600 6,300 6,600 7,100 8,000 8,400 10,000 10,400 11,600 12,500 13,800 14,100 16,000 18,000 18,700 20,000 22,900 25,000

70.61 88.18 104.1 109.3 111.2 131.4 142.7 165.1 171.6 192.0 206.2 228.0 232.2 260.0 306.6 333.6 347.5 432.0 474.8

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

106 20140924

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

Type M Alumoclad Steel Wire Guy Strand

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Applications Messenger Wire, Overhead Ground or Static Wire, Guy Wire. Grades Utilities, Common, Siemens-Martin, High Strength and Extra High Strength Finish Coatings Class A, B and C and Bezinal, a superior corrosive coating of 5% Aluminum and 95% Zinc. Specifications Including but not limited to: • ASTM A-363 Zinc-Coated (Galvanized) Steel Overhead Ground Wire Strand • ASTM A-475 Zinc-Coated Steel Wire Strand • ASTM A-925 -5 % Aluminum-Mischmetal Alloy-Coated Steel Overhead Ground Wire Strand • ASTM A-855 Zinc-5 % Aluminum-Mischmetal Alloy-Coated Steel Wire Strand • ASTM A-640 Zinc-Coated Steel Strand for Messenger Support of Figure 8 Cable

Item #

Strand Diameter (in)

GW5-3/16-062 GW6-3/16-065 GW7-7/32-072 GW8-1/4-080 GW9-9/32-093 GW10-5 /16-104 GW11-5 /16-109 GW12-3/8-120 GW13-7/16-145 GW14-1/2-165 GW15-9/16-188 GW16-5/8-207 GW17-1/2-100 GW18-9/16-113 GW19-5/8-125 GW20-3/4-150 GW21-7/8-177 GW22-1-200

3/16 3/16 7/32 1/4 9/32 5/16 5/16 3/8 7/16 1/2 9/16 5/8 1/2 9/16 5/8 3/4 7/8 1

Coated Number Diameter of Wires (in) per Strand

0.062 0.065 0.072 0.080 0.093 0.104 0.109 0.120 0.145 0.165 0.188 0.207 0.100 0.113 0.125 0.150 0.177 0.200

7 7 7 7 7 7 7 7 7 7 7 7 19 19 19 19 19 19

Approx. Utilities/ Common SiemensHigh Strand Specification Grade Martin Strength Weight Grade Min. Min. Grade Min. Grade Min. /MFT Breaking Breaking. Breaking Breaking (lb) Strength Strength Strength Strength (lb) (lb) (lb) (lb) 73 80 98 121 164 205 225 273 399 517 671 813 504 637 796 1155 1581 2073

2400 — — 4600 — 6000 11500 18000 25000 — — — — — — — —

1150 — 1540 1900 2570 3200 — 4250 5700 7400 9600 11600 7620 9640 11000 16000 21900 28700

1900 — 2560 3150 4250 5350 — 6950 9350 12100 15700 19100 12700 16100 18100 26200 35900 47000

2850 — 3850 4750 6400 8000 — 10800 14500 18800 24500 29600 19100 24100 28100 40800 55800 73200

Extra-High Min. Min. Min. Strength Weight Weight Weight Grade Min. of Coating of Coating of Coating Breaking CLASS A CLASS B CLASS C Strength (lb) (lb) (lb) (lb) 3990 — 5400 6650 8950 11200 — 15400 20800 26900 35000 42400 26700 33700 40200 58300 79700 104500

0.50 0.50 0.50 0.60 0.70 0.80 0.80 0.85 0.90 0.90 1.00 1.00 0.70 0.80 0.85 0.90 0.90 1.00

1.00 1.00 1.00 1.20 1.40 1.60 1.60 1.70 1.80 1.80 2.00 2.00 1.40 1.60 1.70 1.80 1.80 2.00

1.50 1.50 1.50 1.80 2.10 2.40 2.40 2.55 2.70 2.70 3.00 3.00 2.10 2.40 2.55 2.70 2.70 3.00

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

107 20160414

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

Galvanized Guy Wire/Static Wire

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Applications Driven into the ground in construction process for tower, substation, pole and necessary grounding of all major projects. Construction High Carbon Steel with an electrolytically applied copper finish in 1/2", 5/8", 3/4" and 1" diameters in varying lengths. Accessory package is of a high quality bronze alloy to provide both ground rod and accessory excellent electrode quality. Available in single type and sectional ground rod style. Specifications UL Listed product with a .010" copper electroplated finish on high quality high carbon steel to produce a corrosion resistant product in a wide variety of environment.

CATALOG NUMBER Pointed Rods Sectional Rods

^C126 C128 C1210† C585 ^C586 C588 C58813* C5810† C581013* C5812 C348 C34813* C3410† C341013* C110†

^CS586 CS588 CS5810†

CS348 CS3410† CS110

Meets the following industry standards: • ANSI/UL 467 • ANSI/NEMA GR-1 • CSA - Canadian Standard • ANSI C33.8 • Rural Utilities Service - RUS • Steel - cold drawn ASTM-A-1080 - SAE 1010-1035 carbon steel - Tensile strength 80,000-100,000 PSI - Steel Rockwell Hardness—B80 (minimum) • Copper coating is a minimum of .010 inches, meeting or exceeding UL and ANSI specifications. • Company name, UL logo and/or CSA Logo, control number, and part number are located within 12" of the chamfered end of each rod. • Pointed and sectional copperclad ground rods in popular diameters and lengths are available for immediate shipping: 1/2-, 5/8-, 3/4-, and 1inch diameters; 6-, 8-, and 10-foot lengths. • Custom lengths can be produced for customer's special requirements. Minimum quantites required.

DIMENSIONS Nominal Diameter (in)

Actual Diameter +_.005

Length (ft)

1/2" 1/2" 1/2" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 3/4" 3/4" 3/4" 3/4" 1"

.500" .500" .500" .560" .560" .560" .560" .560" .560" .560" .678" .678" .678" .678" .912"

6' 8' 10' 5' 6' 8' 8' 10' 10' 12' 8' 8' 10' 10' 10'

Thread UNC (in)

Length (in)

9/16" 9/16" 9/16" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 3/4" 3/4" 3/4" 3/4" 1"

1 1/16" 1 1/16" 1 1/16" 1 3/16" 1 3/16" 1 3/16" 1 3/16" 1 3/16" 1 3/16" 1 3/16" 1 1/8" 1 1/8" 1 1/8" 1 1/8" 1 1/8"

Weight (lbs)

PACKAGED Sub/Master Bundles

4.22 lbs. 5.62 lbs. 7.03 lbs. 4.27 lbs. 5.12 lbs. 6.83 lbs. 6.83 lbs. 8.54 lbs. 8.54 lbs. 10.3 lbs. 10.0 lbs. 10.0 lbs. 12.5 lbs. 12.5 lbs. 22.51 lbs.

5 /100 5 /100 5 /100 5 /100 5 /100 5 /100 5 /100 5 /100 5 /100 5 / 50 3 / 60 3 / 60 3 / 60 3 / 60 25

^ Not UL Listed † CSA - Canadian Standard * Rural Utilities Services accepted (RUS) – 15 mil average, 13 mil minimum copper coating

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

110 20180201

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

Copper Clad Ground Rods

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Bronze Ground Rod Clamps • UL and CSA listed • High-strength corrosion-resistant copper alloy and/or stainless steel • Suitable for direct burial in earth or concrete • Made in USA ALSO AVAILABLE Universal Grounding Clamps • UL and CSA listing for direct burial in earth or concrete • Fits 1/2", 5/8", and 3/4" ground rods • Accommodates wire range from 1/0 to 10 • All bronze non-corrosive copper alloy and/or stainless steel • Stocked for same day shipping • Saves money by reducing inventory needs • Designed to withstand a minimum 300 inch pounds of torque

STANDARD DUTY BRONZE CLAMPS Part # G-5 G-6 UGC HEAVY DUTY BRONZE CLAMPS WB58H WB34H WB1H

Lay-in Clamps • For rebar applications • UL listed for direct burial in earth or concrete • Fits 1/2" to 1" rebar or ground rods • Wire size range #10 to #2 • Used extensively for grounding to rebar in concrete Drive Ground (Drive-on) Clamps • 80% copper for direct burial in earth or concrete • All bronze non-corrosive copper alloy • 4 or 6 solid copper conductor • Fits 5/8" copperclad ground rods • Easy installation with field hammer completes secure "compression" connection of rod and conductor • Creates low resistance

Rod Size (in)

Conductor Range

Packaged (per box)

1/2" & 5/8" 3/4" 1/2", 5/8", 3/4"

10 SOL - 2 STR 10 SOL - 2 STR 10 SOL to 1/0

50 50 50

5/8" 3/4" 1"

8 SOL - 1/0 STR 8 SOL - 1/0 STR 8 SOL - 4/0 STR

50 50 50

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

111 20180201

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

Bronze Ground Rod Clamps

GROUNDING CABLES/ STATIC WIRE/GUY WIRE

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

TRANSMISSION & DISTRIBUTION CABLES Table of Contents

Bare Aluminum Cables ACSR ..................................................................................................................................401 ACSR/AW ...........................................................................................................................402 ACSS ...................................................................................................................................407 AAC ....................................................................................................................................403 AAAC 6201 Alloy ...............................................................................................................404 ACAR ...................................................................................................................................406 TP Twisted Pair ...................................................................................................................405 ACSR/TW.............................................................................................................................419 ACSS/TW.............................................................................................................................418 Solid Soft-Drawn Tie Wire..................................................................................................408 Covered AL Line Wire Weatherproof.................................................................................409 Packaging Information ACSR and ACSR/AW ..........................................................................................................410 AAC .....................................................................................................................................411 AAAC 6201 Alloy ...............................................................................................................412 TP Twisted Pair....................................................................................................................413 Covered Line Wire ..............................................................................................................414 Covered Aerial Medium Voltage Cable (Spacer Cable or Tree Wire) AAC 2 Layer 15kV ...............................................................................................................420 AAC 3 Layer 15kV-35kV ......................................................................................................421 AAC 3 Layer 35kV Electrical Properties ............................................................................426 Spacer Cable Technical Data for 3 Layer Compounds .....................................................427 AAAC 2 Layer 15kV ............................................................................................................422 AAAC 3 Layer 15kV-35kV ...................................................................................................423 ACSR 2 Layer 15kV.............................................................................................................424 ACSR 3 Layer 15kV-35kV....................................................................................................425 Copper Cables Covered CU Line Wire Weatherproof................................................................................415 Cathodic Protection Cable .................................................................................................416 Transformer Riser Wire (Tap Wire) ....................................................................................417

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

400 20160523

TRANSMISSION.& DISTRIBUTION CABLES

Bare Aluminum Code Name Finder .....................................................................................002

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Bare Aluminum Code Name Finder

Akron Alliance Alliance TP Alton Ames Ames TP Amherst Amherst TP Anaheim Anaheim TP Arbutus Arbutus TP Aster Aster TP Azusa Azusa TP Bersimis/AW Bittern Bittern/AW Bitterroot Bluebell Bluebell TP Bluebird Bluebird/AW Bluebonnet Bluejay Bluejay TP Bluejay/AW Bobolink Bobolink/AW Brahma Brahma/AW Brant Brant/AW Bunting Bunting/AW Butte Butte TP Cairo Camellia Canary Canary/AW Canna Canna TP Canton Cardinal Cardinal/AW

Size

Product Type

Catalog Page

30.58 246.9 246.9 48.69 77.47 77.47 195.7 195.7 155.4 155.4 795 795 2/0 2/0 123.3 123.3 1361 1272 1272 2750 1034 1034 2156 2156 3500 1113 1113 1113 1431 1431 203.2 203.2 397.5 397.5 1193 1193 312.8 312.8 465.4 1000 900 900 397.5 397.5 394.5 954 954

AAAC-6201 AAAC-6201 TP-AAAC-6201 AAAC-6201 AAAC-6201 TP-AAAC-6201 AAAC-6201 TP-AAAC-6201 AAAC-6201 TP-AAAC-6201 AAC TP-AAC AAC TP-AAC AAAC-6201 TP-AAAC-6201 ACSR/AW ACSR ACSR/AW AAC AAC TP-AAC ACSR ACSR/AW AAC ACSR TP-ACSR ACSR/AW ACSR ACSR/AW ACSR ACSR/AW ACSR ACSR/AW ACSR ACSR/AW AAAC-6201 TP-AAAC-6201 AAAC-6201 AAC ACSR ACSR/AW AAC TP-AAC AAAC-6201 ACSR ACSR/AW

404 404 405 404 404 405 404 405 404 405 403 405 403 405 404 405 402 401 402 403 403 405 401 402 403 401 405 402 401 402 401 402 401 402 401 402 404 405 404 403 401 402 403 405 404 401 402

Code Word Carnation Catbird/AW Cattail Chickadee Chickadee TP Chickadee/AW Chukar Chukar/AW Cochin Cochin/AW Cockscomb Cockscomb TP Columbine Condor Condor/AW Coot Coot/AW Coreopsis Cosmos Cosmos TP Cowslip Crane/AW Creeper TP Crow/AW Cuckoo Cuckoo/AW Curlew Curlew/AW Daffodil Dahlia Dahlia TP Daisy Daisy TP Darien Day Lily TP Dipper Dipper/AW Dorking Dorking/AW Dotterel Dotterel/AW Dove Dove TP Dove/AW Drake Drake TP Drake/AW

Size

Product Type

Catalog Page

1431 AAC 403 954 ACSR/AW 402 750 AAC 403 397.5 ACSR 401 397.5 TP-ACSR 405 397.5 ACSR/AW 402 1780 ACSR 401 1780 ACSR/AW 402 211.3 ACSR 401 211.3 ACSR/AW 402 900 AAC 403 900 TP-AAC 405 1352 AAC 403 795 ACSR 401 795 ACSR/AW 402 795 ACSR 401 795 ACSR/AW 402 1590 AAC 403 477 AAC 403 477 TP-AAC 405 2000 AAC 403 874.5 ACSR/AW 402 517 TP-AAC 405 715.5 ACSR/AW 402 795 ACSR 401 795 ACSR/AW 402 1034 ACSR 401 1034 ACSR/AW 402 350 AAC 403 556.5 AAC 403 556.5 TP-AAC 405 266.8 AAC 403 266.8 TP-AAC 405 559.5 AAAC-6201 404 596 TP-AAAC-6201 405 1352 ACSR 401 1352 ACSR/AW 402 190.8 ACSR 401 190.8 ACSR/AW 402 176.9 ACSR 401 176.9 ACSR/AW 402 556.5 ACSR 401 556.5 TP-ACSR 405 556.5 ACSR/AW 402 795 ACSR 401 795 TP-ACSR 405 795 ACSR/AW 402

Code Word

Size

Duck/AW Dunlin TP Eagle Eagle/AW Egret Egret/AW Elgin Falcon Falcon/AW Finch Finch/AW Flag Flamingo Flamingo TP Flamingo/AW Flicker Flicker TP Flicker/AW Flint Flycatcher TP Gannet Gannet/AW Gladiolus Gloxinia 12 Goldenrod Goldentuft Goose/AW Grackle Grackle/AW Greeley Grosbeak Grosbeak/AW Grouse Guinea Guinea/AW Gull/AW Hawk Hawk TP Hawk/AW Hawkweed Hawthorn Hen Hen/AW Heron/AW Heuchera Hyacinth Ibis

Product Type

Catalog Page

605 ACSR/AW 402 715.5 TP-ACSR 405 556.5 ACSR 401 556.5 ACSR/AW 402 636 ACSR 401 636 ACSR/AW 402 652.4 AAAC-6201 404 1590 ACSR 401 1590 ACSR/AW 402 1113 ACSR 401 1113 ACSR/AW 402 700 AAC 403 666.6 ACSR 401 666.6 TP-ACSR 405 666.6 ACSR/AW 402 477 ACSR 401 477 TP-ACSR 405 477 ACSR/AW 402 740.8 AAAC-6201 404 516.8 TP-AAAC-6201 405 666.6 ACSR 401 666.6 ACSR/AW 402 1511 AAC 403 666.6 TP-AAC 405 954 AAC 403 450 AAC 403 636 ACSR/AW 402 1193 ACSR 401 1193 ACSR/AW 402 927.2 AAAC-6201 404 636 ACSR 401 636 ACSR/AW 402 80.0 ACSR 401 159.0 ACSR 401 159 ACSR/AW 402 666.6 ACSR/AW 402 477 ACSR 401 477 TP-ACSR 405 477 ACSR/AW 402 1000 AAC 403 1193 AAC 403 477 ACSR 401 477 ACSR/AW 402 500 ACSR/AW 402 650 AAC 403 500 AAC 403 397.5 ACSR 401

TP is Twisted Pair — Bare Aluminum

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

002 20140110

TRANSMISSION.& DISTRIBUTION CABLES

Code Word

TRANSMISSION & DISTRIBUTION CABLES

Bare Aluminum Code Name Finder Code Word Ibis TP Ibis/AW Iris Iris TP Jaeger TP Jessamine Joree Kingbird Kingbird TP Kingbird/AW Kinglet TP Kittiwake TP Kiwi Kiwi/AW Lapwing Lapwing/AW Lark Lark/AW Larkspur Laurel Leghorn Leghorn/AW Lilac Lily TP Linnet Linnet TP Linnet/AW Lupine Magnolia Mallard Mallard/AW Marigold Marigold TP Martin Martin/AW Meadowsweet Merlin Merlin TP Merlin/AW Minorca Minorca/AW Mistletoe Narcissus Nasturtium Nuthatch Nuthatch/AW Orchid

Size

Product Type

Catalog Page

397.5 397.5 2 2 228.2 1750 2513 636 636 636 556.5 596 2167 2167 1590 1590 397.5 397.5 1034 266.8 134.6 134.6 795 3 336.4 336.4 336.4 2500 954 795 795 1113 1114 1352 1352 600 336.4 336.4 336.4 110.8 110.8 556.5 1272 715.5 1511 1511 636

TP-ACSR ACSR/AW AAC TP-AAC TP-ACSR AAC ACSR ACSR TP-ACSR ACSR/AW TP-ACSR TP-ACSR ACSR ACSR/AW ACSR ACSR/AW ACSR ACSR/AW AAC AAC ACSR ACSR/AW AAC TP-AAC ACSR TP-ACSR ACSR/AW AAC AAC ACSR ACSR/AW AAC TP-AAC ACSR ACSR/AW AAC ACSR TP-ACSR ACSR/AW ACSR ACSR/AW AAC AAC AAC ACSR ACSR/AW AAC

405 402 403 405 405 403 401 401 405 402 405 405 401 402 401 402 401 402 403 403 401 402 403 405 401 405 402 403 403 401 402 403 405 401 402 403 401 405 402 401 402 403 403 403 401 402 403

Code Word Orchid TP Oriole Oriole/AW Ortolan Ortolan TP Ortolan/AW Osprey Osprey TP Osprey/AW Ostrich Ostrich/AW Oxlip Oxlip TP Pansy Pansy TP Parakeet Parakeet TP Parakeet/AW Parrot Parrot/AW Partridge Partridge TP Partridge/AW Peachbell Peacock Peacock/AW Pelican Pelican TP Pelican/AW Penguin Penguin TP Penguin/AW Peony Petrel Petrel/AW Petunia Pheasant Pheasant/AW Phlox Phlox TP Phoebe/AW Pigeon Pigeon TP Pigeon/AW Piper/AW Plover Plover/AW

Size

Product Type

Catalog Page

636 336.4 336.4 1034 1034 1034 556.5 556.5 556.5 300 300 4/0 4/0 1 1 556.5 556.5 556.5 1511 1511 266.8 266.8 266.8 6 605 605 477 477 477 4/0 4/0 4/0 300 101.8 101.8 750 1272 1272 3/0 3/0 300 3/0 3/0 3/0 300 1431 1431

TP-AAC ACSR ACSR/AW ACSR TP-ACSR ACSR/AW ACSR TP-ACSR ACSR/AW ACSR ACSR/AW AAC TP-AAC AAC TP-AAC ACSR TP-ACSR ACSR/AW ACSR ACSR/AW ACSR TP-ACSR ACSR/AW AAC ACSR ACSR/AW ACSR TP-ACSR ACSR/AW ACSR TP-ACSR ACSR/AW AAC ACSR ACSR/AW AAC ACSR ACSR/AW AAC TP-AAC ACSR/AW ACSR TP-ACSR ACSR/AW ACSR/AW ACSR ACSR/AW

405 401 402 401 405 402 401 405 402 401 402 403 405 403 405 401 405 402 401 402 401 405 402 403 401 402 401 405 402 401 405 402 403 401 402 403 401 402 403 405 402 401 405 402 402 401 402

Code Word Poppy Poppy TP PtarmiganTP Quail Quail TP Quail/AW Rail Rail/AW Raven Raven TP Raven/AW Redwing Redwing/AW Robin Robin TP Robin/AW Rook Rook TP Rook/AW Rose Ruddy Ruddy/AW Sagebrush Scoter Scoter/AW Siskin TP Skylark/AW Snapdragon Sneezewort Sparate Sparate/AW Sparrow Sparrow TP Sparrow/AW Squab Squab TP Squab/AW Starling Starling/AW Stilt Stilt/AW Surfbird TP Swallow TP Swallow/AW Swan Swan/AW Swanate

Size

Product Type

Catalog Page

1/0 1/0 397.5 2/0 2/0 2/0 954 954 1/0 1/0 1/0 715.5 715.5 1 1 1 636 636 636 4 900 900 2250 636 636 666.6 1272 900 250 2 2 2 2 2 605 605 605 715.5 715.5 715.5 715.5 874.5 3 3 4 4 4

AAC TP-AAC TP-ACSR ACSR TP-ACSR ACSR/AW ACSR ACSR/AW ACSR TP-ACSR ACSR/AW ACSR ACSR/AW ACSR TP-ACSR ACSR/AW ACSR TP-ACSR ACSR/AW AAC ACSR ACSR/AW AAC ACSR ACSR/AW TP-ACSR ACSR/AW AAC AAC ACSR ACSR/AW ACSR TP-ACSR ACSR/AW ACSR TP-ACSR ACSR/AW ACSR ACSR/AW ACSR ACSR/AW TP-ACSR TP-ACSR ACSR/AW ACSR ACSR/AW ACSR

403 405 405 401 405 402 401 402 401 405 402 401 402 401 405 402 401 405 402 403 401 402 403 401 402 405 402 403 403 401 402 401 405 402 401 405 402 401 402 401 402 405 405 402 401 402 401

TP is Twisted Pair — Bare Aluminum

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 002 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Bare Aluminum Code Name Finder Size

Product Type

Catalog Page

Swanate/AW Swift Swift/AW Syringa Tanager/AW Tatler TP Teal Teal/AW Tern Tern TP

4 636 636 477 1034 477 605 605 795 795

ACSR/AW ACSR ACSR/AW AAC ACSR/AW TP-ACSR ACSR ACSR/AW ACSR TP-ACSR

402 401 402 403 402 405 401 402 401 405

Code Word Tern/AW Thrasher Thrasher/AW Trillium Tulip Tulip TP Turacos TP Turkey Twinstone TP Valerian

Size

Product Type

Catalog Page

795 2312 2312 3000 336.4 336.4 636 6 900 250

ACSR/AW ACSR ACSR/AW AAC AAC TP-AAC TP-ACSR ACSR TP-ACSR AAC

402 401 402 403 403 405 405 401 405 403

Code Word Verbena Violet TP Waxwing Waxwing TP Waxwing/AW Wood Duck Wood Duck/AW Zinnia

Size

Product Type

Catalog Page

700 715.5 266.8 266.8 266.8 605 605 500

AAC TP-AAC ACSR TP-ACSR ACSR/AW ACSR ACSR/AW AAC

403 405 401 405 402 401 402 403

TP is Twisted Pair — Bare Aluminum

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

002 20140110

TRANSMISSION.& DISTRIBUTION CABLES

Code Word

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

ACSR

Construction Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; “aluminized” aluminum coated (AZ); or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease. Specifications ACSR bare conductor meets or exceeds the following ASTM specifications: • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes • B-231 Aluminum Conductors, Concentric-Lay-Stranded • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) • B-502 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW) • B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR) • B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR) Notes • Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 52.5% IACS, AC resistance at 60Hz. • Current ratings are based on 75°C conductor temperature, 25°C ambient, 2ft/s wind, 96/watts/sq.ft sun, .05 coefficients of emissivity and absorption.

Item #

Size AWG

Turkey Swan Swanate Sparrow Sparate Robin Raven Quail Pigeon Penguin Waxwing Partridge Ostrich Merlin Linnet Oriole Chickadee Brant Ibis Lark Pelican Flicker

6 4 4 2 2 1 1/0 2/0 3/0 4/0 266.8 266.8 300.0 336.4 336.4 336.4 397.5 397.5 397.5 397.5 477.0 477.0

Stranding Diameter Diameter Diameter Diameter Weight (Al/Stl) Individual Individual Steel Core Complete /MFT Wire Wire (in) Cable Aluminum Aluminum Steel O.D. (lb) (in) (in) (in) 6/1 6/1 7/1 6/1 7/1 6/1 6/1 6/1 6/1 6/1 18/1 26/7 26/7 18/1 26/7 30/7 18/1 24/7 26/7 30/7 18/1 24/7

0.0661 0.0834 0.0772 0.1052 0.0974 0.1181 0.1327 0.1489 0.1672 0.1878 0.1217 0.1013 0.1074 0.1367 0.1137 0.1059 0.1486 0.1287 0.1236 0.1151 0.1628 0.1410

0.0661 0.0834 0.1029 0.1052 0.1299 0.1181 0.1327 0.1489 0.1672 0.1878 0.1217 0.0788 0.0835 0.1367 0.0884 0.1059 0.1486 0.0858 0.0961 0.1151 0.1628 0.0940

0.0661 0.0834 0.1029 0.1052 0.1299 0.1181 0.1327 0.1489 0.1672 0.1878 0.1217 0.2364 0.2505 0.1367 0.2642 0.3117 0.1486 0.2574 0.2882 0.3453 0.1628 0.2820

0.198 0.250 0.257 0.316 0.325 0.354 0.398 0.447 0.502 0.563 0.609 0.642 0.680 0.683 0.720 0.741 0.743 0.772 0.783 0.806 0.814 0.846

24.5 39.0 39.0 62.0 62.0 78.2 98.7 124.3 156.7 197.7 250.3 251.7 282.9 315.8 317.1 318.2 373.1 375.0 374.7 375.8 447.8 450.1

Weight /MFT Steel (lb)

Weight /MFT Total (lb)

11.6 18.4 28.0 29.3 44.7 36.9 46.6 58.7 74.0 93.4 39.2 115.6 129.8 49.5 145.4 208.9 58.5 137.0 171.9 246.8 70.2 164.4

36.1 57.4 67 91.3 106.7 115.1 145.3 183 230.7 291.1 289.5 367.2 412.7 365.2 462.5 527.1 431.6 512 546.6 622.6 518 614.5

Rated Allowable Breaking Ampacity Strength (amp) (lb) 1190 1860 2360 2850 3640 3550 4380 5300 6620 8350 6880 11300 12700 8680 14100 17800 9940 14500 16300 20300 11800 17200

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Rating (amp)

105 140 140 184 184 212 242 276 315 357 449 475 492 519 529 535 576 584 587 594 646 655

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

401 20160520

TRANSMISSION.& DISTRIBUTION CABLES

Applications Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

TRANSMISSION & DISTRIBUTION CABLES

ACSR Item #

Hawk Hen Osprey Parakeet Dove Eagle Peacock Squab Wood Duck Teal Kingbird Swift Rook Grosbeak Scoter Egret Flamingo Gannet Stilt Starling Redwing Coot Cuckoo Drake Tern Condor Mallard Ruddy Canary Rail Cardinal Ortolan Curlew Bluejay Finch Bunting Grackle Bittern Pheasant Dipper Martin Bobolink Plover Nuthatch Parrot

Size AWG

477.0 477.0 556.5 556.5 556.5 556.5 605.0 605.0 605.0 605.0 636.0 636.0 636.0 636.0 636.0 636.0 666.6 666.6 715.5 715.5 715.5 795.0 795.0 795.0 795.0 795.0 795.0 900.0 900.0 954.0 954.0 1033.5 1033.5 1113.0 1113.0 1192.5 1192.5 1272.0 1272.0 1351.5 1351.5 1431.0 1431.0 1510.5 1510.5

Stranding Diameter Diameter Diameter Diameter Weight (Al/Stl) Individual Individual Steel Core Complete /MFT Wire Wire (in) Cable Aluminum Aluminum Steel (O.D.) (lb) (in) (in) (in) 26/7 0.1354 0.1053 0.3159 0.858 449.6 30/7 0.1261 0.1261 0.3783 0.883 451.1 18/1 0.1758 0.1758 0.1758 0.879 522.2 24/7 0.1523 0.1015 0.3045 0.914 525.1 26/7 0.1463 0.1138 0.3414 0.927 525.0 30/7 0.1362 0.1362 0.4086 0.953 526.3 24/7 0.1588 0.1059 0.3177 0.953 570.9 26/7 0.1525 0.1186 0.3558 0.966 570.4 30/7 0.1420 0.1420 0.4260 0.994 572.0 30/19 0.1420 0.0852 0.4260 0.994 572.0 18/1 0.1880 0.1880 0.1880 0.940 597.2 36/1 0.1329 0.1329 0.1329 0.930 596.9 24/7 0.1628 0.1085 0.3255 0.977 600.0 26/7 0.1564 0.1216 0.3648 0.990 597.9 30/7 0.1456 0.1456 0.4368 1.019 601.4 30/19 0.1456 0.0874 0.4370 1.019 601.4 24/7 0.1667 0.1110 0.3330 1.000 629.1 26/7 0.1601 0.1245 0.3730 1.014 628.7 24/7 0.1727 0.1151 0.3453 1.036 675.2 26/7 0.1659 0.1290 0.3870 1.051 675.0 30/19 0.1544 0.0926 0.4630 1.081 676.3 36/1 0.1486 0.1486 0.1486 1.040 746.2 24/7 0.1820 0.1213 0.3640 1.092 749.9 26/7 0.1749 0.1360 0.4080 1.108 750.3 45/7 0.1329 0.0886 0.2548 1.063 749.8 54/7 0.1213 0.1213 0.3639 1.092 749.5 30/19 0.1628 0.0977 0.4885 1.140 751.9 45/7 0.1414 0.0943 0.2829 1.131 848.7 54/7 0.1291 0.1291 0.3873 1.162 849.0 45/7 0.1456 0.0971 0.2913 1.165 899.9 54/7 0.1329 0.1329 0.3987 1.196 900.7 45/7 0.1515 0.1010 0.3030 1.212 974.3 54/7 0.1383 0.1383 0.4149 1.245 974.3 45/7 0.1573 0.1049 0.3147 1.259 1050.0 54/19 0.1436 0.0862 0.4310 1.293 1056.0 45/7 0.1628 0.1085 0.3255 1.302 1125.0 54/19 0.1486 0.0892 0.4460 1.338 1130.0 45/7 0.1681 0.1121 0.3363 1.345 1200.0 54/19 0.1535 0.0921 0.4605 1.382 1206.0 45/7 0.1733 0.1155 0.3465 1.386 1275.0 54/19 0.1582 0.9049 0.4745 1.424 1281.0 45/7 0.1783 0.1189 0.3567 1.427 1350.0 54/19 0.1628 0.0977 0.4885 1.465 1357.0 45/7 0.1832 0.1221 0.3663 1.465 1425.0 54/19 0.1672 0.1003 0.5015 1.505 1431.0

Weight /MFT Steel (lb)

Weight /MFT Total (lb)

206.4 296.2 81.8 191.7 241.0 345.6 208.7 261.8 375.6 367.4 93.6 46.8 219.1 276.2 394.9 386.6 229.7 288.5 246.5 309.7 434.0 58.5 273.8 344.2 146.1 273.6 483.1 165.5 309.9 175.5 328.4 189.8 355.6 204.8 276.1 219.1 402.7 233.9 429.3 248.3 455.8 263.1 483.1 277.4 509.2

656 747.3 604.1 716.9 766 871.8 779.6 832.2 947.7 939.4 690.8 643.7 819.1 874.1 996.3 988 858.8 917.1 921.8 984.7 1110 804.7 1024 1094 895.9 1023 1235 1014 1149 1075 1228 1164 1330 1255 1432 1344 1533 1433 1635 1525 1737 1613 1840 1702 1940

Rated Allowable Breaking Ampacity Strength (amp) (lb) 19500 23800 13700 19800 22500 27800 21600 24300 28900 30000 15700 13800 22600 25200 30400 31500 23700 26400 25500 28400 34600 16800 27900 31500 22100 28200 38400 24400 31900 25900 33800 27700 36600 29800 39100 32000 41900 34100 43500 36200 46300 38300 49100 40100 51700

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Rating (amp)

659 666 711 721 726 734 760 765 774 773 773 769 784 789 798 798 807 812 844 849 859 884 901 907 887 889 918 958 961 993 996 1043 1047 1092 1093 1139 1140 1184 1187 1229 1232 1272 1275 1313 1318

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 401 20150520

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

ACSR Size AWG

Lapwing 1590.0 Falcon 1590.0 Chukar 1780.0 Bluebird 2156.0 Kiwi 2167.0 Thrasher 2312.0 Joree 2515.0 High Mechanical Strength Grouse 80.0 Petrel 101.8 Minorca 110.8 Leghorn 134.6 Guinea 159.0 Dotterel 176.9 Dorking 190.8 Brahma 203.2 Cochin 211.3

Stranding Diameter Diameter Diameter Diameter Weight (Al/Stl) Individual Individual Steel Core Complete /MFT Wire Wire (in) Cable Aluminum Aluminum Steel O.D. (lb) (in) (in) (in) 45/7 0.1880 0.1253 0.3759 1.504 1498.0 54/19 0.1716 0.1030 0.5150 1.545 1507.0 84/19 0.1456 0.0874 0.4370 1.602 1688.0 84/19 0.1602 0.0961 0.4805 1.762 2044.0 72/7 0.1735 0.1157 0.3471 1.735 2055.0 76/19 0.1744 0.0814 0.4070 1.802 2191.0 76/19 0.1819 0.0849 0.4245 1.880 2384.0 8/1 12/7 12/7 12/7 12/7 12/7 12/7 16/19 12/7

0.1000 0.0921 0.0961 0.1059 0.1151 0.1214 0.1261 0.1227 0.1327

0.1670 0.0921 0.0961 0.1059 0.1151 0.1214 0.1261 0.0977 0.1327

0.1670 0.2763 0.2883 0.3177 0.3453 0.3642 0.3783 0.4885 0.3981

0.367 0.461 0.481 0.530 0.576 0.607 0.631 0.714 0.664

75.1 96.0 104.5 127.0 150.0 166.9 180.0 191.7 199.3

Weight /MFT Steel (lb)

Weight /MFT Total (lb)

Rated Allowable Breaking Ampacity Strength (amp) (lb)

Rating (amp)

292.2 537.0 386.6 467.4 248.9 335.4 364.8

1793 2044 2975 2511 2303 2527 2749

42200 54500 51000 60300 49800 56700 61700

N/A N/A N/A N/A N/A N/A N/A

1354 1359 1453 1623 1607 1673 1751

73.9 158.0 172.1 208.9 246.8 274.6 296.3 485.0 328.2

149 254 276 336 396 441 476 675 527

5200 10400 11300 13600 16000 17300 18700 28400 20700

204 237 246 273 297 312 324 341 340

N/A N/A N/A N/A N/A N/A N/A N/A N/A

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

401 20150520

TRANSMISSION.& DISTRIBUTION CABLES

Item #

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

ACSR/AW

Construction Aluminum 1350 H-19 wires, concentrically stranded about an aluminum-clad steel core wire (AW). Specifications • ASTM B-230 Aluminum Wire, 1350-H19 for Electrical Purposes • ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded • ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) • ASTM B-502 Aluminum-Clad Steel Core Wire for Aluminum Conductors, Aluminum-Clad Steel Reinforced • ASTM B-549 Aluminum Conductors Concentric-Lay-Stranded, Aluminum-Clad Steel Reinforced (ACSR/AW)

Item #

Size AWG

Petrel/AW Minorca/AW Leghorn/AW Guinea/AW Dotterel/AW Dorking/AW Brahma/AW Cochin/AW Swan/AW Swanate/AW Swallow/AW Sparrow/AW Sparate/AW Robin/AW Raven/AW Quail/AW Pigeon/AW Penguin/AW Waxwing/AW Partridge/AW Phoebe/AW Ostrich/AW Piper/AW Merlin/AW Linnet/AW Oriole/AW

101.8 110.8 134.6 159 176.9 190.8 203.2 211.3 4 4 3 2 2 1 1/0 2/0 3/0 4/0 266.8 266.8 300 300 300 336.4 336.4 336.4

Stranding Diameter Diameter Diameter Diameter Weight (Al/Stl) Individual Individual Steel Core Complete /MFT Wire Wire (in) Cable Aluminum Aluminum Steel O.D. (lb) (in) (in) (in) 12/7 12/7 12/7 12/7 12/7 12/7 16/19 12/7 6/1 7/1 6/1 6/1 7/1 6/1 6/1 6/1 6/1 6/1 18/1 26/7 18/1 26/7 30/7 18/1 26/7 30/7

0.0921 0.0961 0.1059 0.1151 0.1214 0.1261 0.1227 0.1327 0.0834 0.0772 0.0937 0.1052 0.0974 0.1181 0.1327 0.1489 0.1672 0.1878 0.1217 0.1013 0.1291 0.1074 0.1000 0.1367 0.1137 0.1059

0.0921 0.0961 0.1059 0.1151 0.1214 0.1261 0.0977 0.1327 0.0834 0.1029 0.0937 0.1052 0.1299 0.1181 0.1327 0.1489 0.1672 0.1878 0.1217 0.0788 0.1291 0.0835 0.1000 0.1367 0.0884 0.1059

0.2763 0.2883 0.3177 0.3453 0.3642 0.3783 0.4885 0.3981 0.0834 0.1029 0.0094 0.1052 0.1295 0.1181 0.1327 0.1489 0.1672 0.1878 0.1217 0.2364 0.1291 0.2505 0.3000 0.1367 0.2642 0.3117

0.4610 0.4810 0.5300 0.5760 0.6070 0.6310 0.7140 0.6640 0.2500 0.2570 0.0281 0.3160 0.3240 0.3540 0.3980 0.4470 0.5020 0.5630 0.6080 0.6420 0.6460 0.6800 0.7000 0.6830 0.7200 0.7410

133.70 145.60 176.90 209.00 232.50 250.80 409.50 277.60 39.00 39.00 49.30 62.10 62.10 78.30 98.80 124.40 156.80 197.80 250.40 251.90 282.00 283.10 283.90 316.00 317.30 318.40

Weight /MFT AW (lb)

Weight /MFT Total (lb)

96.10 104.60 127.10 150.10 167.00 180.10 191.90 199.40 15.60 23.70 19.70 24.80 37.70 31.30 39.50 49.80 62.70 79.10 33.20 98.00 37.40 110.00 157.70 41.90 123.20 176.90

229.80 250.30 303.90 359.10 399.50 430.90 601.40 477.00 54.60 62.70 68.90 86.90 99.70 109.50 138.30 174.10 220.00 276.90 283.60 349.80 319.40 393.10 441.60 357.90 440.50 495.30

Resistance Allowable /MFT Ampacity* DC 20°C (amp) (ohm) 0.143 0.131 0.108 0.091 0.082 0.076 0.066 0.069 0.390 0.380 0.309 0.245 0.239 0.195 0.154 0.122 0.097 0.077 0.064 0.062 0.057 0.055 0.054 0.050 0.049 0.048

281 297 335 372 398 418 464 445 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Rating* (amp)

N/A N/A N/A N/A N/A N/A N/A N/A 145 148 N/A 194 198 225 260 301 347 402 451 465 N/A 500 N/A 522 537 547

*Please contact AWG where Ampacity/Rating is N/A.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

402 20150601

TRANSMISSION.& DISTRIBUTION CABLES

Applications ACSR/AW cables are used for overhead transmission and distribution lines. Also, as neutral messenger for low voltage multiplex cables.

TRANSMISSION & DISTRIBUTION CABLES

ACSR/AW Item #

Chickadee/AW Brant/AW Ibis/AW Lark/AW Pelican/AW Flicker/AW Hawk/AW Hen/AW Heron/AW Osprey/AW Parakeet/AW Dove/AW Eagle/AW Peacock/AW Squab/AW WoodDuck/AW Teal/AW Duck/AW Kingbird/AW Rook/AW Grosbeak/AW Scoter/AW Egret/AW Swift/AW Goose/AW Flamingo/AW Gannet/AW Gull/AW Stilt/AW Starling/AW Redwing/AW Crow/AW Coot/AW Cuckoo/AW Drake/AW Tern/AW Condor/AW Mallard/AW Crane/AW Ruddy/AW Canary/AW Catbird/AW Rail/AW Cardinal/AW Tanager/AW

Size AWG

397.5 397.5 397.5 397.5 477 477 477 477 500 556.5 556.5 556.5 556.5 605 605 605 605 605 636 636 636 636 636 636 636 666.6 666.6 666.6 715.5 715.5 715.5 715.5 795 795 795 795 795 795 874.5 900 900 954 954 954 1033.5

Stranding Diameter Diameter Diameter Diameter Weight (Al/Stl) Individual Individual Steel Core Complete /MFT Wire Wire (in) Cable Aluminum Aluminum Steel O.D. (lb) (in) (in) (in) 18/1 24/7 26/7 30/7 18/1 24/7 26/7 30/7 30/7 18/1 24/7 26/7 30/7 24/7 26/7 30/7 30/19 54/7 18/1 24/7 26/7 30/7 30/19 24/7 26/7 24/7 26/7 54/7 24/7 26/7 30/19 54.7 36/1 24/7 26/7 45/7 54/7 30/19 54/7 45/7 54/7 36/1 45/7 54/7 36/1

0.1486 0.1287 0.1236 0.1151 0.1628 0.1410 0.1354 0.1261 0.1291 0.1758 0.1523 0.1463 0.1362 0.1588 0.1525 0.1420 0.1420 0.1059 0.1880 0.1628 0.1564 0.1456 0.1456 0.1329 0.1085 0.1667 0.1601 0.1110 0.1727 0.1659 0.1544 0.1150 0.1486 0.1820 0.1749 0.1329 0.1213 0.1628 0.1272 0.1414 0.1291 0.1628 0.1456 0.1329 0.1694

0.1486 0.0858 0.0961 0.1151 0.1628 0.0940 0.1053 0.1261 0.1291 0.1758 0.1015 0.1138 0.1362 0.1059 0.1186 0.1420 0.0852 0.1059 0.1880 0.1085 0.1216 0.1456 0.0874 0.1329 0.1087 0.1110 0.1245 0.1110 0.1151 0.1290 0.0926 0.1150 0.1486 0.1213 0.1360 0.0886 0.1213 0.0977 0.1272 0.0943 0.1291 0.1628 0.0971 0.1329 0.1694

0.1486 0.2574 0.2882 0.3453 0.1628 0.2820 0.3159 0.3783 0.3870 0.1758 0.3045 0.3414 0.4086 0.3177 0.3558 0.4260 0.4260 0.3180 0.1880 0.3255 0.3648 0.4368 0.4370 0.1329 0.3260 0.3330 0.3730 0.3330 0.3453 0.3870 0.4630 0.3450 0.1486 0.3640 0.4080 0.2660 0.3639 0.4885 0.3810 0.2829 0.3873 0.1628 0.2913 0.3987 0.1694

0.7430 0.7720 0.7830 0.8060 0.8140 0.8460 0.8580 0.8830 0.9040 0.8790 0.9140 0.9270 0.9530 0.9530 0.9660 0.9940 0.9940 0.9530 0.9400 0.9770 0.9900 1.0190 1.0190 0.9300 0.9770 1.3330 1.0140 0.9990 1.0360 1.0510 1.0810 1.0350 1.0400 1.0920 1.1070 1.0630 1.0920 1.1400 1.4440 1.1310 1.1620 1.1400 1.1650 1.1960 1.1860

373.30 375.30 374.90 376.20 448.10 450.30 449.90 451.50 473.40 522.50 525.40 525.30 526.50 571.50 571.00 572.50 572.50 571.80 597.60 600.50 600.50 601.80 601.80 597.50 600.20 629.30 629.30 628.40 675.60 675.60 676.90 673.70 750.60 750.70 748.00 750.50 750.10 752.40 824.40 849.60 849.60 896.30 900.50 900.60 970.60

Weight /MFT AW (lb)

Weight /MFT Total (lb)

49.50 116.10 145.60 209.00 59.50 139.39 174.90 250.76 262.96 69.34 162.45 204.29 292.45 176.87 221.75 318.01 311.30 176.87 79.46 185.66 233.23 334.26 327.62 39.64 186.19 194.65 244.38 194.38 208.98 262.48 367.74 208.41 232.02 232.00 292.00 123.74 232.02 409.52 255.01 140.20 262.80 59.47 148.64 278.58 64.40

422.90 491.30 520.50 585.20 507.60 589.70 624.80 702.20 736.40 591.90 687.90 729.60 819.00 748.40 792.70 890.50 883.80 748.60 677.10 786.10 833.80 936.00 929.40 637.10 786.40 823.90 873.70 822.70 884.60 938.10 1044.60 882.10 982.60 982.70 1040.00 874.20 982.10 1161.90 1079.40 989.80 1112.40 955.80 1049.10 1179.20 1035.00

Resistance Allowable /MFT Ampacity* DC 20°C (amp) (ohm) 0.043 0.042 0.041 0.041 0.036 0.035 0.035 0.034 0.032 0.031 0.030 0.030 0.029 0.027 0.027 0.027 0.027 0.027 0.027 0.026 0.026 0.025 0.025 0.027 0.026 0.025 0.025 0.025 0.023 0.023 0.023 0.023 0.021 0.021 0.022 0.021 0.021 0.020 0.019 0.019 0.018 0.018 0.018 0.017 0.017

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Rating* (amp)

580 592 597 608 651 663 669 682 N/A 715 731 737 751 770 777 N/A 791 N/A 778 794 801 N/A N/A N/A N/A 818 825 N/A N/A 863 878 N/A N/A 913 922 896 913 938 N/A 970 986 N/A 1003 1022 N/A

*Please contact AWG where Ampacity/Rating is N/A.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 402 20150601

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

ACSR/AW

Ortolan/AW Curlew/AW Bluejay/AW Finch/AW Bunting/AW Grackle/AW Skylark/AW Bittern/AW Pheasant/AW Dipper/AW Martin/AW Bersimis/AW Bobolink/AW Plover/AW Nuthatch/AW Parrot/AW Lapwing/AW Falcon/AW Chukar/AW Bluebird/AW Kiwi/AW Thrasher/AW

Size AWG

1033.5 1033.5 1113 1113 1192.5 1192.5 1272 1272 1272 1351.5 1351.5 1361 1431 1431 1510.5 1510.5 1590 1590 1780 2156 2167 2312

Stranding Diameter Diameter Diameter Diameter Weight (Al/Stl) Individual Individual Steel Core Complete /MFT Wire Wire (in) Cable Aluminum Aluminum Steel O.D. (lb) (in) (in) (in) 45/7 54/7 45/7 54/19 45/7 54/19 36/1 45/7 54/19 45/7 54/19 42/7 45/7 54/19 45/7 54/19 45/7 54/19 84/19 84/19 72/7 76/19

0.1515 0.1383 0.1573 0.1436 0.1628 0.1486 0.1880 0.1681 0.1535 0.1733 0.1582 0.1799 0.1783 0.1628 0.1832 0.1672 0.1880 0.1716 0.1456 0.1602 0.1735 0.1744

0.1010 0.1383 0.1049 0.0862 0.1085 0.0892 0.1880 0.1121 0.0921 0.1155 0.9490 0.1000 0.1189 0.0977 0.1221 0.1003 0.1253 0.1030 0.0874 0.0961 0.1157 0.0814

0.3030 0.4149 0.3147 0.4310 0.3255 0.4460 0.1880 0.3363 0.4605 0.3465 0.4745 0.3000 0.3567 0.4885 0.3663 0.5015 0.3759 0.5150 0.4370 0.4805 0.3471 0.4070

1.2120 1.2450 1.2580 1.2910 1.3020 1.3380 1.3160 1.3450 1.3810 1.3860 1.4240 1.3800 1.4270 1.4650 1.4650 1.5050 1.5040 1.5450 1.6020 1.7620 1.7350 1.8020

975.00 975.20 1051.00 1056.00 1126.00 1131.00 1195.00 1201.00 1207.00 1276.00 1282.00 1284.00 1351.00 1358.00 1426.00 1432.00 1501.00 1509.00 1691.00 2045.00 2056.00 2193.00

Weight /MFT AW (lb)

Weight /MFT Total (lb)

160.81 301.65 173.47 318.54 185.66 341.34 79.30 198.12 363.69 210.41 386.10 157.69 222.93 409.52 235.05 431.59 247.64 454.93 327.62 396.10 211.13 284.30

1135.80 1276.80 1224.40 1374.60 1311.50 1472.30 1274.50 1398.70 1570.80 1486.40 1668.00 1441.20 1573.60 1767.10 1660.70 1863.80 1749.00 1963.60 2018.50 2441.10 2267.30 2477.40

Resistance Allowable /MFT Ampacity* DC 20°C (amp) (ohm) 0.016 0.016 0.015 0.015 0.014 0.014 0.013 0.013 0.013 0.013 0.012 0.013 0.012 0.012 0.011 0.011 0.011 0.011 0.010 0.008 0.008 0.007

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Rating* (amp)

1054 1074 1103 N/A N/A N/A N/A N/A 1216 N/A N/A N/A 1283 N/A N/A N/A 1365 N/A N/A N/A N/A N/A

*Please contact AWG where Ampacity/Rating is N/A.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

402 20150601

TRANSMISSION.& DISTRIBUTION CABLES

Item #

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

ACSS

Construction ACSS is a composite concentric-lay stranded conductor. Steel strands form the central core of the conductor with one or more layers of aluminum 1350-0 wire stranded around it. The steel core carries most or all of the mechanical load of the conductor due to the (fully annealed or soft) temper aluminum. Steel core wires are protected from corrosion by galvanizing, aluminizing, or mischmetal alloy coating. Corrosion protection should be selected to suit the environment to which the conductor will be exposed. High strength steel core is also available. Standards ACSS conductor meets or exceeds the following ASTM specifications: • B500 Metallic Coated Stranded Steel Core for Use in Overhead Electrical Conductors. • B609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers for Electrical Purposes. • B802 Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR). • B803 High-Strength Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire for Use in Overhead Electrical Conductors. • B856 Concentric-Lay-Stranded Aluminum Conductors, Coated Steel Supported (ACSS). • B958 Extra-High-Strength and Ultra-High-Strength Class A Zinc-5% Aluminum-Mischmetal AlloyCoated Steel Core Wire for Use in Overhead Electrical Conductors. Options • Regular-Strength Class C galvanized steel core • High-Strength Class A galvanized steel core • Extra-High-Strength Class A galvanized steel core • Ultra-High-Strength Class A galvanized steel core • Regular-Strength Class A zinc-5% aluminum misch-metal alloy-coated steel core • High-Strength Class A zinc-5% aluminum misch-metal alloy-coated steel core • Extra-High-Strength Class A zinc-5% aluminum misch-metal alloy-coated steel core • Ultra-High-Strength Class A zinc-5% aluminum misch-metal alloy-coated steel core • Aluminum-clad steel core • 250°C Operating Temperature rating utilizing either the zinc-5% aluminum mischmetal alloycoated steel core wires, or the aluminum-clad steel core wires. • Non-specular surface finish

Item #

Size Stranding Dia. AWG Al/St Ind. or Wire KCMIL (in)

Partridge ACSS Junco ACSS Ostrich ACSS Woodcock ACSS Linnet ACSS Oriole ACSS Ptarmigan ACSS Brant ACSS Ibis ACSS Lark ACSS

266.8 266.8 300.0 336.4 336.4 336.4 397.5 397.5 397.5 397.5

26 / 7 30 / 7 26 / 7 22 / 7 26 / 7 30 / 7 20 / 7 24 / 7 26 / 7 30 / 7

0.1013 0.0943 0.1074 0.1237 0.1137 0.1059 0.1410 0.1287 0.1236 0.1151

Dia. Ind. Wire (in)

Dia. Steel Core (in)

0.0788 0.0943 0.0835 0.0687 0.0884 0.1059 0.0627 0.0858 0.0961 0.1151

0.2364 0.2829 0.2505 0.2061 0.2652 0.3177 0.1881 0.2574 0.2883 0.3453

Dia. Weight Weight Complete /MFT /MFT Cable Aluminum Steel (in) (lb) (lb) 0.642 0.660 0.680 0.701 0.720 0.741 0.752 0.772 0.783 0.806

251.3 251.3 282.5 317.1 316.6 317.7 374.5 374.4 374.1 375.3

115.6 165.5 129.8 84.8 145.5 208.7 73.2 137.0 171.9 246.6

Weight /MFT Total (lb)

Rated Resist. Resist. Ampacity Strength DC@20°C AC@75°C (lb) /MFT /MFT (ohm) (ohm)

366.9 416.8 412.3 401.9 462.1 526.4 447.7 511.4 546.0 621.9

8,880 11,700 10,000 7,610 11,200 14,800 7,090 11,000 13,000 17,500

0.0619 0.0615 0.0551 0.0495 0.0491 0.0488 0.0421 0.0417 0.0416 0.0413

0.0761 0.0756 0.0677 0.0609 0.0604 0.0600 0.0518 0.0514 0.0512 0.0508

812 822 877 933 945 957 1034 1047 1054 1068

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

407 20140925

TRANSMISSION.& DISTRIBUTION CABLES

Applications Used for overhead distribution and transmission lines. Designed to operate continuously at elevated temperatures up to 250°C without loss of strength. It sags less under emergency electrical loadings than ASCR; it is self-damping if prestretched during installation, and the final sags are not affected by long term creep of aluminum. The advantages make ACSS especially useful in reconductoring applications requiring increased current with existing tensions and clearances, new line applications where structures can be economized because of reduced conductor sag, new line applications requiring high emergency loadings, and lines where aeolian vibration is a problem.

TRANSMISSION & DISTRIBUTION CABLES

ACSS Item #

Size Stranding Dia. AWG Al/St Ind. or Wire KCMIL (in)

Tailorbird ACSS 477.0 Flicker ACSS 477.0 Hawk ACSS 477.0 Hen ACSS 477.0 Sapsucker ACSS 556.5 Parakeet ACSS 556.5 Dove ACSS 556.5 Eagle ACSS 556.5 Peacock ACSS 605.0 Squab ACSS 605.0 Wood Duck ACSS 605.0 Teal ACSS 605.0 Goldfinch ACSS 636.0 Rook ACSS 636.0 Grosbeak ACSS 636.0 Scoter ACSS 636.0 Egret ACSS 636.0 Flamingo ACSS 666.6 Gannet ACSS 666.6 Stilt ACSS 715.5 Starling ACSS 715.5 Redwing ACSS 715.5 Cuckoo ACSS 795.0 Drake ACSS 795.0 Macaw ACSS 795.0 Tern ACSS 795.0 Condor ACSS 795.0 Mallard ACSS 795.0 Ruddy ACSS 900.0 Canary ACSS 900.0 Corncrake ACSS 954.0 Redbird ACSS 954.0 Rail ACSS 954.0 Towhee ACSS 954.0 Canvasback ACSS 954.0 Snowbird ACSS 1033.5 Ortolan ACSS 1033.5 Curlew ACSS 1033.5 Bluejay ACSS 1113.0 Finch ACSS 1113.0 Cardinal ACSS 954.0 Bunting ACSS 1192.5 Grackle ACSS 1192.5 Bittern ACSS 1272.0 Pheasant ACSS 1272.0 Dipper ACSS 1351.0

20 / 7 24 / 7 26 / 7 30 / 7 22 / 7 24 / 7 26 / 7 30 / 7 24 / 7 26 / 7 30 / 7 30 / 19 22 / 7 24 / 7 26 / 7 30 / 7 30 / 19 24 / 7 26 / 7 24 / 7 26 / 7 30 / 19 24 / 7 26 / 7 42 / 7 45 / 7 54 / 7 30 / 19 45 / 7 54 / 7 20 / 7 24 / 7 45 / 7 48 / 7 30 / 19 42 / 7 45 / 7 54 / 19 45 / 7 54 / 19 54 / 7 45 / 7 54 / 19 45 / 7 54 / 19 45 / 7

0.1544 0.1410 0.1354 0.1261 0.1590 0.1523 0.1463 0.1362 0.1588 0.1525 0.1420 0.1420 0.1700 0.1628 0.1564 0.1456 0.1456 0.1667 0.1601 0.1727 0.1659 0.1544 0.1820 0.1749 0.1376 0.1329 0.1213 0.0628 0.1414 0.1291 0.2184 0.1994 0.1456 0.1410 0.1783 0.1569 0.1515 0.1383 0.1573 0.1436 0.1329 0.1628 0.1486 0.1681 0.1535 0.1733

Dia. Ind. Wire (in)

Dia. Steel Core (in)

0.0686 0.0940 0.1053 0.1261 0.0883 0.1015 0.1138 0.1362 0.1059 0.1186 0.1420 0.0852 0.0944 0.1085 0.1216 0.1456 0.0874 0.1111 0.1245 0.1151 0.1290 0.0926 0.1213 0.1360 0.0764 0.0886 0.1213 0.0977 0.0943 0.1291 0.0971 0.1329 0.0971 0.1097 0.1070 0.0872 0.1010 0.1383 0.1049 0.0862 0.1329 0.1085 0.0892 0.1121 0.0921 0.1155

0.2058 0.2820 0.3159 0.3783 0.2649 0.3045 0.3414 0.4068 0.3177 0.3558 0.4260 0.4260 0.2832 0.3255 0.3648 0.4368 0.4370 0.3333 0.3735 0.3453 0.3870 0.4630 0.3639 0.4080 0.2292 0.2658 0.3639 0.4885 0.2829 0.3873 0.2913 0.3987 0.2913 0.3291 0.5350 0.2616 0.3030 0.4149 0.3747 0.4310 0.3987 0.3255 0.4460 0.3363 0.4605 0.3465

Dia. Weight Weight Complete /MFT /MFT Cable Aluminum Steel (in) (lb) (lb) 0.823 0.846 0.858 0.883 0.901 0.914 0.927 0.953 0.953 0.966 0.994 0.994 0.963 0.977 0.990 1.019 1.019 1.000 1.014 1.036 1.051 1.081 1.092 1.108 1.055 1.063 1.092 1.140 1.131 1.162 1.165 1.196 1.165 1.175 1.248 1.203 1.212 1.245 1.258 1.293 1.196 1.302 1.338 1.345 1.382 1.386

449.1 449.4 449.0 450.4 523.9 524.3 524.2 525.5 570.0 569.5 571.2 571.2 598.9 599.1 599.0 600.5 600.5 628.2 627.7 674.2 674.0 675.3 748.8 749.1 749.0 748.6 748.4 750.7 847.4 847.7 898.5 898.8 898.5 898.8 900.5 973.9 972.8 972.8 1048.7 1053.9 898.3 1123.4 1128.6 1197.7 1204.3 1272.9

87.6 164.5 206.4 296.0 145.1 191.8 241.0 345.3 208.7 261.8 375.3 367.5 165.9 219.1 275.2 394.6 386.7 229.7 288.5 246.6 309.7 434.1 273.9 344.3 108.6 146.1 273.9 483.2 165.5 310.2 175.5 328.7 175.5 224.0 579.6 141.5 189.9 356.0 204.8 376.1 328.7 219.1 402.8 233.9 429.4 248.3

Weight /MFT Total (lb)

Rated Resist. Resist. Ampacity Strength DC@20°C AC@75°C (lb) /MFT /MFT (ohm) (ohm)

536.7 613.9 655.4 746.4 669.0 716.1 765.2 870.8 778.7 831.3 946.5 938.7 764.8 818.2 874.2 995.1 987.2 857.9 916.2 920.8 983.7 1109.4 1022.7 1093.4 857.6 894.7 1022.3 1233.9 1012.9 1157.9 1074.0 1227.5 1074.0 1122.8 1480.1 1115.4 1162.7 1328.8 1253.5 1430.0 1227.0 1342.5 1531.4 1431.6 1633.7 1521.2

8,490 13,000 15,600 21,000 12,600 15,200 18,200 24,500 16,500 19,700 26,100 26,600 14,100 17,300 20,700 27,400 28,000 18,200 21,700 19,500 23,300 30,800 21,700 25,900 11,800 14,200 16,600 34,300 15,800 24,600 16,700 26,000 16,700 19,700 41,100 15,400 18,100 28,200 19,500 30,400 26,000 20,900 32,600 22,300 34,100 23,700

0.0351 0.0348 0.0346 0.0344 0.0299 0.0298 0.0297 0.0295 0.0274 0.0273 0.0271 0.0272 0.0262 0.0261 0.0260 0.0258 0.0258 0.0249 0.0248 0.0232 0.0231 0.0230 0.0209 0.0209 0.0211 0.0210 0.0209 0.0207 0.0186 0.0184 0.0175 0.0174 0.0175 0.0175 0.0172 0.0162 0.0162 0.0161 0.0150 0.0150 0.0174 0.0140 0.0140 0.0131 0.0131 0.0124

0.0433 0.0429 0.0427 0.0424 0.0370 0.0368 0.0366 0.0363 0.0339 0.0337 0.0334 0.0335 0.0324 0.0322 0.0321 0.0318 0.0319 0.0308 0.0306 0.0287 0.0286 0.0284 0.0259 0.0257 0.0262 0.0263 0.0026 0.0255 0.0233 0.0236 0.0219 0.0217 0.0220 0.0218 0.0214 0.0204 0.0204 0.0206 0.0190 0.0193 0.0223 0.0178 0.0180 0.0167 0.0169 0.0158

1165 1180 1188 1204 1297 1306 1315 1331 1379 1389 1407 1406 1415 1425 1435 1454 1453 1470 1480 1540 1550 1570 1650 1662 1621 1618 1618 1683 1755 1756 1834 1859 1824 1842 1897 1924 1921 1924 2017 2015 1825 2110 2108 2200 2200 2289

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 407 20140925

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

ACSS Size Stranding Dia. AWG Al/St Ind. or Wire KCMIL (in)

Martin ACSS 1351.0 Bobolink ACSS 1431.0 Plover ACSS 1431.0 Nuthatch ACSS 1510.0 Parrot ACSS 1510.0 Ratite ACSS 1590.0 Lapwing ACSS 1590.0 Falcon ACSS 1590.0 Chukar ACSS 1780.0 Mockingbird ACSS 2034.0 Roadrunner ACSS 2057.0 Bluebird ACSS 2156.0 Kiwi ACSS 2167.0 Thrasher ACSS 2312.0 Joree ACSS 2515.0

54 / 19 45 / 7 54 / 19 45 / 7 54 / 19 42 / 7 45 / 7 54 / 19 84 / 19 72 / 7 76 / 19 84 / 19 72 / 7 76 / 19 76 / 19

0.1582 0.1783 0.1628 0.1832 0.1672 0.1946 0.1880 0.1716 0.1456 0.1681 0.1645 0.1602 0.1735 0.1744 0.1819

Dia. Ind. Wire (in)

Dia. Steel Core (in)

0.0949 0.1189 0.0977 0.1221 0.1003 0.1081 0.1253 0.1030 0.0874 0.1121 0.0768 0.0961 0.1157 0.0814 0.0849

0.4745 0.3567 0.4885 0.3663 0.5015 0.3243 0.3759 0.5150 0.4370 0.3363 0.3840 0.4805 0.3471 0.4070 0.4245

Dia. Weight Weight Complete /MFT /MFT Cable Aluminum Steel (in) (lb) (lb) 1.424 1.427 1.465 1.466 1.505 1.492 1.504 1.544 1.602 1.681 1.700 1.762 1.735 1.802 1.880

1279.1 1347.5 1354.6 1422.5 1428.8 1498.1 1498.1 1505.0 1685.4 1925.7 1946.5 2040.4 2051.4 2187.9 2380.1

455.9 263.1 483.2 277.5 509.2 217.5 292.2 537.0 386.7 233.9 298.6 467.5 249.2 335.4 364.9

Weight /MFT Total (lb)

Rated Resist. Resist. Ampacity Strength DC@20°C AC@75°C (lb) /MFT /MFT (ohm) (ohm)

1735.0 1610.6 1837.8 1700.0 1938.0 1715.6 1790.3 2042.0 2072.1 2159.6 2245.1 2507.9 2300.6 2523.3 2745.0

36,200 25,100 38,400 26,500 40,500 23,400 27,900 42,600 35,400 27,200 31,700 42,100 29,000 35,600 38,700

0.0123 0.0117 0.0117 0.0111 0.0110 0.0105 0.0105 0.0105 0.0094 0.0083 0.0082 0.0078 0.0078 0.0073 0.0067

0.0160 0.0150 0.0151 0.0143 0.0144 0.0136 0.0136 0.0137 0.0122 0.0110 0.0108 0.0103 0.0104 0.0098 0.0092

2288 2375 2375 2459 2460 2543 2543 2545 2751 2960 2992 3106 3080 3218 3390

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

407 20140925

TRANSMISSION.& DISTRIBUTION CABLES

Item #

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

AAC

Construction Aluminum alloy 1350-H19 wires, concentrically stranded. Specifications AAC bare conductors meet or exceed the following ASTM specifications: • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes • B-231 Aluminum Conductors, Concentric-Lay-Stranded • B-400 Compact Round Concentric-Lay-Stranded Aluminum 1350 Conductors Notes • Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 52.5% IACS, AC resistance at 60Hz. • Current ratings are based on 75°C conductor temperature, 25°C ambient, 2ft/s wind, 96/watts/sq.ft sun, .05 coefficients of emissivity and absorption.

Item #

Size AWG

No. of Wires

CLASS

Diameter Individual Wire (in)

Diameter Complete Cable O.D. (in)

Cross Sectional Area (in2)

Weight /MFT (lb)

Rated Breaking Strength (lb)

Peachbell Rose Iris Pansy Poppy Aster Phlox Oxlip Sneezewort Valerian Daisy Laurel Peony Tulip Daffodil Canna Goldentuft Cosmos Syringa Zinnia Hyacinth

6 4 2 1 1/0 2/0 3/0 4/0 250 250 266.8 266.8 300 336.1 350 397.5 450 477 477 500 500

7 7 7 7 7 7 7 7 7 19 7 19 19 19 19 19 19 19 37 19 37

A A A & AA A & AA A & AA A & AA A & AA A & AA AA A A & AA A A A A A & AA AA AA A AA A

.0612 .0772 .0974 .1093 .1228 .1379 .1548 .1739 .1890 .1147 .1953 .1185 .1257 .1331 .1357 .1447 .1538 .1584 .1135 .1622 .1162

.184 .232 .292 .328 .368 .414 .464 .522 .567 .574 .586 .593 .629 .666 .679 .724 .769 .793 .795 .811 .813

.0206 .0328 .0521 .0657 .0829 .1045 .1318 .1662 .1964 .1964 .2095 .2095 .2356 .2642 .2749 .3122 .3534 .3746 .3746 .3927 .329

24.6 39.2 62.3 99.1 78.5 124.9 157.5 198.6 234.7 234.7 250.5 250.5 286.1 315.8 328.6 373.2 422.4 447.8 447.8 469.4 469.4

563 881 1350 1640 1990 2510 3040 3830 4520 4660 4830 4970 5480 6150 6390 7110 7890 8360 8690 8760 9110

Resistance Resistance /MFT /MFT DC 20°C AC 75°C (ohm) (ohm) .658 .414 .260 .207 .164 .130 .103 .0817 .0691 .0691 .0648 .0648 .0576 .0514 .0494 .0435 .0384 .0362 .0362 .0346 .0346

.805 .506 .318 .252 .202 .159 .126 .0999 .0846 .0846 .0793 .0793 .0706 .0630 .0605 .0534 .0472 .0445 .0445 .0425 .0425

Rating (amp)

103 138 185 214 247 286 331 383 425 426 443 444 478 513 526 570 616 639 639 658 658

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

403 20140921

TRANSMISSION.& DISTRIBUTION CABLES

Applications Stranded 1350 aluminum conductors shown in this section of data are classified as follows: Class AA For bare conductors usually used in overhead lines. Class A For conductors to be covered with weather-resistant materials and for bare conductors where greater flexibility is required.Compact strand conductor for use in bare overhead applications or for use with weather-resistant coverings or insulations is also available. Classes refer to stranding and are an indication of relative conductor flexibility, AA being the least flexible, C the most flexible.

TRANSMISSION & DISTRIBUTION CABLES

AAC Item #

Dahlia Mistletoe Meadowsweet Orchid Heuchera Verbena Flag Violet Nasturtium Petunia Cattail Arbutus Lilac Cockscomb Snapdragon Magnolia Goldenrod Hawkweed Camellia Bluebell Larkspur Marigold Hawthorn Narcissus Columbine Carnation Gladiolus Coreopsis Jessamine Cowslip Sagebrush Lupine Bitterroot Trillium Bluebonnet

Size AWG

No. of Wires

CLASS

Diameter Individual Wire (in)

Diameter Complete Cable O.D. (in)

Cross Sectional Area (in2)

Weight /MFT (lb)

Rated Breaking Strength (lb)

556.5 556.5 600 636 650 700 700 715.5 715.5 750 750 795 795 900 900 954 954 1000 1000 1033.5 1033.5 1113 1192.5 1272 1351.5 1431 1510.5 1590 1750 2000 2250 2500 2750 3000 3500

19 37 37 37 37 37 61 37 61 37 61 37 61 37 61 37 61 37 61 37 61 61 61 61 61 61 61 61 61 91 91 91 91 127 127

AA A A & AA A & AA AA AA A AA A AA A AA A AA A AA A AA A AA A A & AA A & AA A & AA A & AA A & AA A & AA AA AA A A A A A A

.1711 .1226 .1273 .1311 .1326 .1375 .1071 .1391 .1083 .1424 .1109 .1446 .1142 .1560 .1215 .1606 .1251 .1644 .1280 .1671 .1302 .1351 .1398 .1444 .1489 .1532 .1574 .1614 .1694 .1482 .1572 .1657 .1739 .1537 .1660

.856 .858 .891 .918 .928 .963 .964 .974 .975 .997 .998 1.026 1.028 1.092 1.094 1.124 1.126 1.150 1.152 1.170 1.172 1.216 1.258 1.300 1.340 1.379 1.417 1.454 1.525 1.630 1.729 1.823 1.913 1.996 2.158

.4371 .4371 .4712 .4995 .5105 .5498 .5498 .5620 .5620 .5891 .5891 .6244 .6244 .7069 .7069 .7493 .7493 .7854 .7854 .8117 .8117 .8742 .9366 .9990 1.062 1.124 1.186 1.249 1.374 1.571 1.767 1.964 2.160 2.356 2.749

522.4 522.4 563.2 597.0 610.2 657.1 657.1 671.7 671.7 704.0 704.0 746.3 746.3 844.9 844.9 895.6 895.6 938.7 938.7 970.2 970.2 1045 1119 1194 1269 1343 1418 1493 1643 1877 2131 2370 2607 2844 3350

9750 9940 10700 11400 11600 12500 12900 12800 13100 13100 13500 13900 14300 15400 15900 16400 16900 17200 17700 17700 18300 19700 21000 22000 23400 24300 25600 27000 29700 32200 37500 41900 46100 50300 58700

Resistance Resistance /MFT /MFT DC 20°C AC 75°C (ohm) (ohm) .0311 .0311 .0288 .0272 .0266 .0247 .0247 .0242 .0242 .0230 .0230 .0217 .0217 .0192 .0192 .0181 .0181 .0173 .0173 .0167 .0167 .0155 .0145 .0136 .0128 .0121 .0144 .0109 .00988 .00864 .00776 .00698 .00635 .00582 .00499

.0382 .0382 .0355 .0335 .0328 .0305 .0305 .0299 .0299 .0286 .0286 .0271 .0270 .0239 .0239 .0226 .0226 .0216 .0216 .0210 .0210 .0195 .0183 .0173 .0163 .0155 .0147 .0141 .0129 .0115 .0105 .00969 .00900 .00834 .00756

Rating (amp)

703 704 738 765 775 812 812 823 823 847 847 878 879 948 948 982 983 1010 1011 1031 1032 1079 1124 1169 1212 1253 1294 1333 1408 1518 1612 1706 1793 1874 2024

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 403 20140921

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

AAAC 6201 Alloy

Construction Standard 6201-T81 high strength aluminum conductors, conforming to ASTM Specification B-399, are concentric-lay stranded, similar in construction and appearance to 1350 grade aluminum conductors. Standard 6201 alloy conductors were developed to fill the need for an economical conductor for overhead applications requiring higher strength than that obtainable with 1350 grade aluminum conductors, but without a steel core. The DC resistance at 20°C of the 6201-T81 conductors and of the standard ACSRs of the same diameter are approximately the same. Conductors of the 6201-T81 alloys are harder and, therefore, have a greater resistance to abrasion than conductors of 1350-H19 grade aluminum. Specifications AAAC bare conductor meets or exceeds the following ASTM specifications: • B-398 Aluminum Alloy 6201-T81 Wire for Electrical Purposes • B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors. Notes • Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 52.5% IACS, AC resistance at 60Hz. • Current ratings are based on 75°C conductor temperature, 25°C ambient, 2ft/s wind, 96/watts/sq.ft sun, .05 coefficients of emissivity and absorption

Item #

Akron Alton Ames Azusa Anaheim Amherst Alliance Butte Canton Cairo Darien Elgin Flint Greely

Size KCM KCM

Strand

Approx EC Cond. with Equivalent Resistance

Stranding

Diameter Individual Wire (in)

Diameter Complete Cable (in)

Cross Sectional Area (in2)

Weight /MFT (lb)

Rated Breaking Strength (lb)

Rating (amp)

30.58 48.69 77.47 123.3 155.4 195.7 246.9 312.8 394.5 465.4 559.5 652.4 740.8 927.2

7/w 7/w 7/w 7/w 7/w 7/w 7/w 19/w 19/w 19/w 19/w 19/w 37/w 37/w

6 4 2 1/0 2/0 3/0 4/0 266.8 336.4 397.5 477.0 556.5 636.0 795.0

6/1 6/1 6/1 6/1 6/1 6/1 6/1 26/7 26/7 26/7 26/7 26/7 26/7 26/7

.0661 .0834 .1052 .1327 .1490 .1672 .1878 .1283 .1441 .1565 .1716 .1853 .1415 .1583

.198 .250 .316 .398 .447 .502 .563 .642 .721 .783 .858 .927 .991 1.108

.0240 .0382 .0608 .0968 .1221 .1537 .1939 .2456 .3098 .3655 .4394 .5124 .5818 .7282

28.7 45.7 72.7 115.7 145.9 183.7 231.8 293.6 370.3 436.9 525.2 612.4 695.5 870.4

1110 1760 2800 4460 5390 6790 8560 11000 13300 15600 18800 21900 24400 30500

107 143 191 256 296 342 395 460 532 590 663 729 790 908

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

404 20160418

TRANSMISSION.& DISTRIBUTION CABLES

Applications Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a highstrength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives AAAC higher resistance to corrosion than ACSR.

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

ACAR

Construction Concentric-stranded cable formed by a core of 6201-T81 aluminum alloy wires surrounded by 1350 H-19 aluminum wires concentrically stranded over the alloy core. Some designs have 1350 aluminum wires and 6201 alloy wires intercalated in the same layer. Features Very good ratio Tensile Strength to Weight. Highly resistant to corrosion. Standards • B230 Aluminum 1350-H19 Wire for Electrical Purposes. • B398 Aluminum-Alloy 6201-T81 Wire for Electrical Purposes. • B524 Concentric-Lay-Stranded Aluminum Conductors, Aluminum-Alloy Reinforced (ACAR, 1350/6201).

Item #

ACAR-355.0 ACAR-465.9 ACAR-503.6 ACAR-653.1 ACAR-739.8 ACAR-739.8 ACAR-853.7 ACAR-853.7 ACAR-927.2 ACAR-927.2 ACAR-1024.5 ACAR-1024.5 ACAR-1081.0 ACAR-1081.0 ACAR-1109.0 ACAR-1109.0 ACAR-1172.0 ACAR-1172.0 ACAR-1197.0 ACAR-1197.0 ACAR-1280.0 ACAR-1280.0 ACAR-1361.0 ACAR-1527.0 ACAR-1703.0 ACAR-1933.0 ACAR-2267.0 ACAR-2493.0 ACAR-2493.0

Size KCMIL

Stranding (EC/6201)

Diameter Individual Wires – 6201 (in)

Diameter Individual Wires – 1350 (in)

Diameter Complete Cable (in)

Weight /MFT (lb)

Rated Strength (lb)

Resistance. DC@20°C (ohms)

Resistance AC@75°C (ohms)

Allowable Ampacity (amp)

355.0 465.9 503.6 653.1 739.8 739.8 853.7 853.7 927.2 927.2 1024.5 1024.5 1081.0 1081.0 1109.0 1109.0 1172.0 1172.0 1197.0 1197.0 1280.0 1280.0 1361.0 1527.0 1703.0 1933.0 2267.0 2493.0 2493.0

12/7 12/7 12/7 12/7 30/7 18/19 30/7 18/19 30/7 18/19 30/7 18/19 30/7 18/19 30/7 18/19 30/7 18/19 30/7 18/19 30/7 18/19 42/19 42/19 42/19 42/19 42/19 72/19 54/37

0.1367 0.1566 0.1628 0.1854 0.1414 0.1414 0.1519 0.1519 0.1583 0.1583 0.1664 0.1664 0.1709 0.1709 0.1731 0.1731 0.1780 0.1780 0.1799 0.1799 0.1860 0.1860 0.1494 0.1582 0.1671 0.1780 0.1928 0.1655 0.1655

0.1367 0.1566 0.1628 0.1854 0.1414 0.1414 0.1519 0.1519 0.1583 0.1583 0.1664 0.1664 0.1709 0.1709 0.1731 0.1731 0.1780 0.1780 0.1799 0.1799 0.1860 0.1860 0.1494 0.1582 0.1671 0.1780 0.1928 0.1655 0.1655

0.6830 0.7830 0.8140 0.9270 0.9900 0.9900 1.0630 1.0630 1.1080 1.1080 1.1650 1.1650 1.1960 1.1960 1.2120 1.2120 1.2460 1.2460 1.2590 1.2590 1.3020 1.3020 1.3440 1.4240 1.5040 1.6020 1.7350 1.8210 1.8210

332.1 435.8 471.1 611.0 692.7 691.6 799.3 798.0 868.2 866.7 959.3 957.7 1012.1 1010.5 1038.4 1036.6 1097.3 1095.5 1120.8 1118.9 1198.5 1196.5 1273.6 1428.8 1593.5 1808.8 2142.0 2356.9 2354.5

8500 11000 11900 15400 15300 18800 17500 21500 19000 23400 20900 25800 22100 27200 22700 27900 24000 29500 24500 30200 26200 32200 30300 33600 37500 42500 49900 50400 57600

0.0514 0.0392 0.0362 0.0279 0.0240 0.0252 0.0208 0.0218 0.0192 0.0201 0.0173 0.0182 0.0164 0.0172 0.0160 0.0168 0.0152 0.0159 0.0148 0.0156 0.0139 0.0146 0.0133 0.0118 0.0106 0.0094 0.0081 0.0072 0.0074

0.0624 0.0477 0.0441 0.0342 0.0296 0.0308 0.0257 0.0268 0.0238 0.0247 0.0216 0.0225 0.0205 0.0213 0.0200 0.0208 0.0190 0.0198 0.0187 0.0194 0.0175 0.0182 0.0168 0.0151 0.0137 0.0123 0.0108 0.0099 0.0101

519 616 646 760 831 814 907 890 955 936 1015 995 1048 1028 1065 1044 1101 1080 1115 1094 1160 1139 1196 1314 1363 1465 1594 1687 1670

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

406 20140921

TRANSMISSION.& DISTRIBUTION CABLES

Applications Used as bare overhead transmission cable and as primary and secondary distribution cable. A good strength-to-weight ratio makes ACAR applicable where both ampacity and strength are prime considerations in line design; for equal weight, ACAR offers higher strength and ampacity than ACSR.

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

TP Twisted Pair

Construction TP Conductor is composed of two identical bare conductors twisted together with a left-hand lay. This gives the cable a rectangular spiral shape. This spiral shape disrupts the forces created by steady cross winds which cause cable vibration, by presenting a continuously changing projected cable diameter to the wind. This spiral shape, together with less torsional stiffness and varying bending stiffness also reduces or eliminates cable galloping due to combined ice and wind loads. The component conducts of TP can be conductor types AAC, AAAC, ACAR, ACSR, AAC/TW or ACSR/TW meeting the requirements of the appropriate ASTM standards. Specifications TP Conductor meets or exceeds the following ASTM specifications for the subconductor of each assembly: • B-911/B-911M for Twisted Pair Conductor • B-231 Aluminum Conductor, Concentric-Lay Stranded. • B-232 Aluminum Conductor, Concentric-Lay Stranded, Coated Steel Reinforced (ACSR). • B-399 Concentric-Lay Stranded 6201-T81 Aluminum Alloy Conductors. • B-524 Concentric-Lay Stranded Aluminum Conductors, Aluminum Alloy Reinforced (ACAR, 1350/6201) • B-779 Shaped Wire Compact Concentric-Lay Stranded Aluminum Conductors, Steel Reinforced (ACSR/TW.) Notes • Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 52.5% IACS, AC resistance at 60Hz. • Current ratings are based on 75°C conductor temperature, 25°C ambient, 2ft/s wind, 96/watts/sq.ft sun, .05 coefficients of emissivity and absorption.

Item #

Lily TP Ames TP Swallow TP Iris TP SparrowTP Pansy TP Robin TP Poppy TP Azuza TP Raven TP Aster TP Anaheim TP Quail TP Phlox TP Amherst TP Pigeon TP Oxlip TP Alliance TP Penguin TP

Conductor Construction Type

AAC AAAC ACSR AAC ACSR AAC ACSR AAC AAAC ACSR AAC AAAC ACSR AAC AAAC ACSR AAC AAAC ACSR

2x#3 2x#2 2x#3 2x#2 2x#2 2x#1 2x#1 2x1/0 2x1/0 2x1/0 2x2/0 2x2/0 2x2/0 2x3/0 2x3/0 2x3/0 2x4/0 2x4/0 2x4/0

Total Kcmil

Stranding Aluminum

Stranding Steel

Outer Dimension (in)

Equivalent Diameter (in)

Weight /MFT Alum (lb)

Weight /MFT Steel (lb)

Weight /MFT Total (lb)

Rated Breaking Strength (lb)

Rating (amp)

105.2 154.9 105.2 132.7 132.7 167.4 167.4 211.2 246.6 211.2 266.2 310.8 266.2 335.6 391.4 335.6 423.2 493.8 423.2

7x0.0867 7x0.1052 6x0.0937 7x0.0974 6x0.1052 7x0.1093 6x0.1181 7x0.1228 7x0.1327 6x0.1327 7x0.1379 7x0.1490 6x0.1489 7x0.1548 7x0.1672 6x0.1672 7x0.1739 7x0.1878 6x0.1878

N/A N/A 1x0.0937 N/A 1x0.1052 N/A 1x0.1181 N/A N/A 1x0.1327 N/A N/A 1x0.1489 N/A N/A 1x0.1672 N/A N/A 1x0.1878

0.260x0.520 0.316x0.632 0.281x0.562 0.292x0.584 0.316x0.631 0.328x0.656 0.355x0.710 0.368x0.736 0.396x0.796 0.396x0.790 0.414x0.828 0.447x0.894 0.447x0.894 0.464x0.926 0.502x1.004 0.502x1.004 0.552x1.044 0.563x1.126 0.563x1.126

0.426 0.517 0.460 0.478 0.517 0.537 0.581 0.602 0.652 0.652 0.678 0.732 0.732 0.760 0.822 0.822 0.854 0.922 0.922

99.0 145.4 98.4 124.6 124.0 157.0 156.4 198.2 231.4 197.2 250.0 291.8 248.6 315.0 367.4 313.4 397.2 463.6 395.4

N/A N/A 46.4 N/A 59.0 N/A 74.0 N/A N/A 93.2 N/A N/A 117.6 N/A N/A 148.2 N/A N/A 188.8

99.0 145.4 144.8 124.6 183.0 157.0 230.4 198.2 231.4 290.4 250.0 291.8 366.2 315.0 367.4 462.0 397.2 463.6 582.2

2180 5600 4600 2700 5700 3280 7100 3980 8920 8760 5020 10780 10600 6080 13580 13240 7660 17120 16700

272 328 275 316 316 367 371 426 437 420 495 510 484 574 592 582 667 692 642

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

405 20140921

TRANSMISSION.& DISTRIBUTION CABLES

Applications TP Twisted Pair Conductor bare aluminum construction, is designed for use in overhead applications subject to Aeolian vibration and galloping due to wind and ice. TP Conductor can be strung to the maximum allowable tension limits without the need for additional vibration protection.

TRANSMISSION & DISTRIBUTION CABLES

TP Twisted Pair Item #

Jaeger TP Daisy TP Butte TP Waxwing TP Partridge TP Tulip TP Merlin TP Linnett TP Canna TP Chickadee TP Ptarmigan TP Ibis TP Cosmos TP Pelican TP Taller TP Flicker-TP Hawk TP Dahila TP Flycatcher TP Creeper TP OspreyTP Kinglet TP Parakeet TP Dove TP Day Lily TP Kittiwake TP Squab TP Orchid TP Kingbird TP Turacos TP Rook TP Gloxinia TP Siskin TP Flamingo TP Violet TP Dunlin TP Arbutus TP Tern TP Drake TP Cockscomb TP Surfbird TP Twinstone TP Bluebell TP Marigold TP Ortolan TP Bluejay TP

Conductor Construction Type

ACSR AAC AAAC ACSR ACSR AAC ACSR ACSR AAC ACSR ACSR ACSR AAC ACSR ACSR ACSR ACSR AAC ACSR ACSR ACSR ACSR ACSR ACSR AAC ACSR ACSR AAC ACSR ACSR ACSR AAC ACSR ACSR AAC ACSR AAC ACSR ACSR AAC ACSR ACSR AAC AAC ACSR ACSR

2x228.2 2x266.8 2x266.8 2x266.8 2x266.8 2x336.4 2x336.4 2x336.4 2x397.5 2x397.5 2x397.5 2x397.5 2x477.0 2x447.0 2x477.0 2x477.0 2x477.0 2x556.5 2x516.8 2x516.8 2x556.5 2x556.5 2x556.5 2x556.5 2x596.0 2x596.0 2x605.0 2x636.0 2x636.0 2x636.0 2x636.0 2x666.6 2x666.6 2x666.6 2x715.5 2x715.5 2x795.0 2x795.0 2x795.0 2x900.0 2x874.5 2x900.0 2x1033.5 2x1113.5 2x1033.5 2x1113.0

Total Kcmil

Stranding Aluminum

456.4 18x0.1126 533.6 7x0.1953 533.6 19x0.1283 533.6 18x0.1217 533.6 26x0.1013 672.8 19x0.1331 672.8 18x0.1387 672.8 26x0.1137 795.0 19x0.1447 795.0 18x0.1486 795.0 20x0.1400 795.0 26x0.1236 954.0 19x0.1584 954.0 18x0.1628 954.0 20x0.1544 954.0 24x0.1410 954.0 26x0.1354 1113 19x0.1711 1033.5 18x0.1694 1033.5 20x0.1607 1113 18x0.1758 1113 20x0.1667 1113 24x0.1523 1113 26x0.1463 1192 19x0.1771 1192 18x0.1820 1210 20x0.1739 1272 37x0.1311 1272 18x0.1880 1272 20x0.1783 1272 24x0.1626 1333 37x0.1342 1334 20x0.1826 1334 24x0.1667 1431 37x0.1391 1431 20x0.1891 1590 37x0.1466 1590 45x0.1329 1590 26x0.1749 1800 37x0.1580 1749 20x0.2091 1800 20x0.2121 2067 37x0.1671 2226 61x0.1351 2067 45x0.1515 2226 45x0.1573

Stranding Steel

Outer Dimension (in)

1x0.1126 0.536x1.126 N/A 0.586x1.172 N/A 0.642x1.284 1x0.1217 0.609x1.218 7x0.0788 0.642x1.284 N/A 0.666x1.332 1x0.1367 0.684x1.368 7x0.0884 0.721x1.442 N/A 0.724x1.448 1x0.1486 0.743x1.486 7x0.0626 0.752x1.504 7x0.0961 0.783x1.566 N/A 0.793x1.586 1x0.1628 0.814x1.628 7x0.0686 0.823x1.647 7x0.0940 0.846x1.692 7x0.1053 0.858x1.716 N/A 0.856x1.712 1x0.1694 0.847x1.694 7x0.0714 0.857x1.714 1x0.1758 0.879x1.758 7x0.0741 0.889x1.778 7x0.1015 0.914x1.828 7x0.1138 0.927x1.854 N/A 0.886x1.771 1x0.1820 0.910x1.820 7x0.0773 0.928x1.855 N/A 0.918x1.836 1x0.1880 0.940x1.880 7x0.0792 0.951x1.902 7x0.1085 0.977x1.954 N/A 0.939x1.879 7x0.0812 1.974x1.948 7x0.1111 1.000x2.000 N/A 1.974x1.945 7x0.0840 1.005x2.016 N/A 1.026x2.052 7x0.0886 1.064x2.128 7x0.1360 1.108x2.216 N/A 1.092x2.184 7x0.0929 1.115x2.23 7x0.0943 1.131x2.262 N/A 1.170x2.340 N/A 1.216x2.432 7x0.1010 1.212x2.424 7x0.1049 1.258x2.516

Equivalent Diameter (in)

Weight /MFT Alum (lb)

Weight /MFT Steel (lb)

Weight /MFT Total (lb)

Rated Breaking Strength (lb)

Rating (amp)

0.922 0.959 1.051 0.997 1.051 1.090 1.120 1.180 1.185 1.216 1.231 1.282 1.298 1.333 1.347 1.385 1.405 1.401 1.387 1.403 1.439 1.455 1.496 1.518 1.450 1.490 1.518 1.503 1.539 1.557 1.599 1.538 1.594 1.637 1.594 1.650 1.680 1.742 1.814 1.788 1.825 1.851 1.915 1.991 1.984 2.059

428.5 501 587.2 501 504 632 632 634 746 746 747 750 896 896 895 900 900 1045 970 974 1044 1050 1050 1050 1119 1119 1141 1194 1194 1200 1200 1251 1258 1258 1343 1350 1493 1500 1500 1690 1650 1698 1940 2090 1948 2100

67.1 N/A N/A 78.6 230 N/A 100 292 N/A 118 146 344 N/A 140 175 328 414 N/A 152 190 164 204 384 482 N/A 175 222 N/A 186 234 438 N/A 246 450 N/A 262 N/A 292 688 N/A 322 332 N/A N/A 380 410

495.6 501 587.2 580 734 632 732 926 746 864 893 1094 896 1036 1070 1228 1314 1045 1122 1164 1208 1254 1434 1532 1119 1294 1383 1194 1380 1434 1638 1251 1504 1718 1343 1612 1493 1792 2188 1690 1972 2030 1940 2090 2328 2510

12200 9700 22000 13800 22600 12300 17400 28200 14200 19900 22200 32600 16700 23600 26400 34400 39000 19500 25500 28300 27400 30500 39600 45200 20400 29800 33200 22800 31400 34800 45400 23800 36600 47600 25600 39200 27800 44200 63000 30800 47600 48200 35400 39400 55400 59600

720 774 810 789 810 902 917 923 984 1001 1007 1030 1108 1128 1134 1153 1162 1224 1188 1194 1247 1254 1275 1290 1279 1304 1324 1335 1359 1368 1391 1375 1410 1434 1439 1474 1536 1577 1620 1658 1674 1703 1801 1882 1853 1939

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 405 20140921

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

ASCR/TW

SPECIFICATIONS • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes • B-231 Aluminum Conductors, Concentric-Lay-Stranded • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) • B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) • B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR) • B-779 Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors, Steel-Reinforced (ACSR/TW). CONSTRUCTION Aluminum alloy 1350-H19 trapezoidal shaped wires, concentrically stranded about a steel core. Core wire for ACSR/TW is available with class A, B, or C galvanizing; “aluminized” aluminum coated (AZ); or aluminum-clad (AW1). Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease. NOTES * Ampacity calculated assuming: ambient 250°C, conductor 75°C, wind 2 ft./sec., sun.

Item #

Merlin/TW Flicker/TW Hawk/TW Parakeet/TW Dove/TW Swift/TW Rook/TW Grosbeak/TW Tern/TW Puffin/TW Condor/TW Drake/TW Phoenix/TW Rail/TW Cardinal/TW Snowbird/TW Ortolan/TW Curlew/TW Avocet/TW Bluejay/TW Finch/TW Oxbird/TW Bunting/TW

Conductor Conductor Type Stranding Size Area Area Code No. Al St Al Total Layers (sq.in) (sq.in) of Al 336.4 477.0 477.0 556.5 556.5 636.0 636.0 636.0 795.0 795.0 795.0 795.0 954.0 954.0 954.0 1033.5 1033.5 1033.5 1113.0 1113.0 1113.0 1192.5 1192.5

0.2642 0.3747 0.3746 0.4371 0.4371 0.4995 0.4995 0.4995 0.6244 0.6244 0.6244 0.6244 0.7493 0.7493 0.7493 0.8117 0.8117 0.8117 0.8742 0.8742 0.8742 0.9366 0.9366

0.2788 0.4233 0.4356 0.4937 0.5083 0.5133 0.5643 0.5808 0.6675 0.6919 0.7053 0.7261 0.7876 0.8011 0.8464 0.8534 0.8678 0.9169 0.9191 0.9347 0.9851 0.9848 1.0013

6 13 16 13 16 3 13 16 7 10 13 16 5 7 13 5 7 13 5 7 13 5 7

2 2 2 2 2 3 2 2 2 2 2 2 3 3 2 3 3 2 3 3 3 2 3

14 18 18 18 20 27 19 20 17 18 20 20 30 32 20 30 32 20 30 33 38 30 34

1x0.1367 7x0.0940 7x0.1053 7x0.1015 7x0.1138 1x0.1329 7x0.1085 7x0.1216 7x0.0886 7x0.1108 7x0.1203 7x0.1360 7x0.0837 7x0.0971 7x0.1329 7x0.0871 7x0.1010 7x0.1383 7x0.0904 7x0.1049 19x0.0862 7x0.0936 7x0.1085

Outside Diameter Weight Rated Resistance Allowable Complete Steel Total Aluminum Steel Strength DC@20°C AC@75°C Ampacities Conductor Core (lb/MFT) (lb/MFT) (lb/MFT) (lb) (OMS/ (OMS/ * (in) (in) MFT) MFT) 0.630 0.776 0.789 0.835 0.852 0.850 0.890 0.908 0.960 0.980 0.993 1.010 1.044 1.061 1.084 1.089 1.102 1.129 1.129 1.143 1.185 1.167 1.181

0.1367 0.2820 0.3159 0.3045 0.3414 0.1329 0.3255 0.3648 0.2658 0.3324 0.3639 0.4080 0.2511 0.2913 0.3987 0.2613 0.3030 0.4149 0.2712 0.3147 0.4310 0.2808 0.3255

365.0 612.8 655.0 714.9 764.5 646.0 816.0 873.5 892.0 975.3 1021.0 1092.0 1032.0 1075.0 1226.0 1115.0 1165.0 1327.0 1201.0 1257.0 1429.0 1286.0 1343.0

315.5 448.4 448.7 523.2 523.5 599.2 597.9 598.4 745.9 746.9 747.2 747.8 901.6 900.0 897.3 973.8 975.2 971.1 1048.9 1052.2 1052.6 1123.0 1124.0

49.5 164.4 206.3 191.7 241.0 46.8 219.1 275.1 146.1 228.4 273.8 344.2 130.4 175.0 328.7 141.2 189.8 355.9 152.1 204.8 376.4 163.0 219.0

8560 17200 19400 20000 22600 13500 22900 25400 21000 25900 28200 31800 23700 25900 33500 25700 28100 36300 27500 30300 39100 29500 32400

0.0510 0.0357 0.0356 0.0306 0.0305 0.0272 0.0268 0.0267 0.0215 0.0215 0.0214 0.0213 0.0181 0.0180 0.0178 0.0167 0.0167 0.0165 0.0155 0.0155 0.0154 0.0144 0.0144

0.0625 0.0437 0.0435 0.0375 0.0374 0.0335 0.0329 0.0327 0.0266 0.0264 0.0264 0.0263 0.0224 0.0224 0.0221 0.0208 0.0207 0.0204 0.0193 0.0193 0.0191 0.0180 0.0181

508 641 645 706 711 750 766 772 869 876 880 887 967 973 985 1017 1021 1036 1063 1069 1084 1111 1114

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

419 20160520

TRANSMISSION.& DISTRIBUTION CABLES

APPLICATION Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductor, Steel-Reinforced (ACSR/TW) is designed for use as a bare overhead conductor. There are two designs of ACSR/TW. One design gives an equal area of aluminum when compared to the standard ACSR conductor sizes. The other design gives an overall outside diameter equal to standard ACSR conductor sizes. Use of this conductor in the equal area design allows equal ampacity in a smaller diameter conductor when compared with standard ACSR conductor. Use of this conductor in the equal diameter design allows more ampacity in an equal diameter conductor when compared with standard ACSR conductor.

TRANSMISSION & DISTRIBUTION CABLES

ASCR/TW Item #

Conductor Conductor Type Stranding Size Area Area Code No. Al St Al Total Layers (sq.in) (sq.in) of Al

Grackel/TW 1192.5 Scissortail/TW 1272.0 Bittern/TW 1272.0 Pheasant/TW 1272.0 Dipper/TW 1351.0 Martin/TW 1351.0 Bobolink/TW 1431.0 Plover/TW 1431.0 Lapwing/TW 1590.0 Falcon/TW 1590.0 Chukar/TW 1780.0 Bluebird/TW 2156.0 Monongahela/TW 405.1 Mohawk/TW 571.7 Calumet/TW 565.3 Mystic/TW 666.6 Oswego/TW 664.8 Nechako/TW 768.9 Maumee/TW 768.2 Wabash/TW 762.8 Kettle/TW 957.2 Fraser/TW 946.7 Columbia/TW 966.2 Suwannee/TW 959.6 Cheyenne/TW 1168.1 Genesee/TW 1158.0 Hudson/TW 1158.4 Catawba/TW 1272.0 Nelson/TW 1257.1 Yukon/TW 1233.6 Truckee/TW 1372.5 Mackenzie/TW 1359.7 Thames/TW 1334.6 St. Croix/TW 1467.8 Miramichi/TW 1455.3 Merrimack/TW 1433.6 Platte/TW 1569.0 Potomac/TW 1557.4 Rio Grande/TW 1533.3 Schuylkill/TW 1657.4 Pecos/TW 1622.0 Pee Dee/TW 1758.6 James/TW 1730.6 Athabaska/TW 1949.6 Cumberland/TW 1926.9 Powder/TW 2153.8 Santee/TW 2627.3

0.9366 0.9991 0.9990 0.9990 1.0615 1.0615 1.1236 1.1239 1.2488 1.2488 1.3986 1.0934 0.3181 0.4490 0.4439 0.5236 0.5221 0.6039 0.6034 0.5992 0.7518 0.7436 0.7589 0.7537 0.9175 0.9095 0.9098 0.9991 0.9874 0.9689 1.0780 1.0679 1.3480 1.1529 1.1430 1.1250 1.2323 1.2232 1.2043 1.3020 1.2739 1.3810 1.3590 1.5312 1.5134 1.6912 2.0630

1.0554 1.0505 1.0681 1.1256 1.1348 1.1959 1.2017 1.2664 1.3351 1.4071 1.5120 1.8312 0.3362 0.5074 0.5165 0.5914 0.6072 0.6220 0.6819 0.6966 0.8038 0.8168 0.8573 0.8762 0.9646 0.9733 1.0281 1.0505 1.0557 1.0925 1.1334 1.1418 1.1809 1.2124 1.2222 1.2677 1.2957 1.3079 1.3571 1.3920 1.4429 1.4770 1.5314 1.6377 1.7049 1.8290 2.2268

13 5 7 13 7 13 7 13 7 13 8 8 6 13 16 13 16 3 13 16 7 10 13 16 5 7 13 5 7 13 5 7 13 5 7 13 5 7 13 7 13 7 13 7 13 8 8

3 3 3 3 3 3 3 3 3 3 3 4 2 2 2 2 2 3 2 2 3 3 2 2 3 3 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4

38 30 35 39 35 42 36 44 36 42 37 64 14 18 18 20 20 27 20 20 32 35 21 22 30 33 26 30 35 38 30 36 39 33 36 39 33 36 39 36 39 37 34 44 42 64 64

19x0.0892 7x0.0967 7x0.1121 19x0.9210 7x0.1155 19x0.0949 7x0.1189 19x0.0977 7x0.1253 19x0.1030 19x0.0874 19x0.0961 1x0.1520 7x0.1030 7x0.1147 7x0.1111 7x0.1244 1x0.1520 7x0.1195 7x0.1331 7x0.0973 7x0.1154 7x0.1338 7x0.1493 7x0.0926 7x0.1078 7x0.1467 7x0.0967 7x0.1115 19x0.0910 7x0.1004 7x0.1559 19x0.0944 7x0.1041 7x0.1200 19x0.0978 7x0.1074 7x0.1241 19x0.1012 7x0.128 19x0.1064 7x0.1319 19x0.1075 7x0.1392 19x0.1133 19x0.0961 19x0.1062

Outside Diameter Weight Rated Resistance Allowable Complete Steel Total Aluminum Steel Strength DC@20°C AC@75°C Ampacities Conductor Core (lb/MFT) (lb/MFT) (lb/MFT) (lb) (OMS/ (OMS/ * (in) (in) MFT) MFT) 1.225 1.203 1.220 1.264 1.256 1.300 1.291 1.337 1.358 1.408 1.445 1.608 0.680 0.846 0.858 0.913 0.927 0.930 0.977 0.990 1.060 1.077 1.092 1.108 1.155 1.165 1.196 1.203 1.213 1.245 1.248 1.259 1.290 1.292 1.302 1.340 1.334 1.345 1.382 1.386 1.424 1.427 1.470 1.504 1.545 1.602 1.762

0.4460 0.2901 0.3363 0.4605 0.3465 0.4745 0.3567 0.4885 0.3759 0.5150 0.4370 0.4805 0.1520 0.3090 0.3438 0.3330 0.3732 0.1520 0.3585 0.3993 0.2919 0.3462 0.4014 0.4479 0.2778 0.3234 0.4401 0.2901 0.3345 0.4550 0.3012 0.3477 0.4720 0.3123 0.3600 0.4890 0.3222 0.3723 0.5060 0.3840 0.5320 0.3957 0.5375 0.4176 0.5665 0.4805 0.5310

1530.0 1372.0 1433.0 1632.0 1522.0 1734.0 1613.0 1836.0 1791.0 2040.0 2063.0 2515.0 441.0 734.7 714.8 856.3 913.4 781.9 987.8 1047.0 1079.0 1142.0 1241.0 1318.0 1260.0 1308.0 1489.0 1372.0 1417.0 1586.0 1481.0 1530.0 1713.0 1585.0 1640.0 1840.0 1693.0 1755.0 1968.0 1868.0 2107.0 1982.0 2221.0 2199.0 2471.0 2498.0 3048.0

1127.0 1198.0 1198.0 1202.0 1274.0 1278.0 1350.0 1353.0 1499.0 1503.0 1676.0 2047.0 379.8 537.3 523.1 626.6 625.4 720.7 722.1 717.0 902.8 894.0 908.0 903.0 1100.4 1092.0 1089.0 1198.0 1185.7 1166.5 1293.4 1280.0 1261.6 1383.0 1372.0 1356.0 1478.0 1468.0 1449.0 1563.0 1533.0 1658.0 1636.0 1838.0 1821.0 2030.0 2477.0

403.0 174.0 234.0 430.0 248.0 456.0 263.0 483.0 292.0 537.0 387.0 468.0 61.2 197.4 191.7 229.7 288.0 61.2 265.7 330.0 176.2 248.0 333.0 415.0 159.6 216.0 400.0 174.0 231.3 419.5 187.6 250.0 451.4 202.0 268.0 434.0 215.0 287.0 519.0 305.0 574.0 324.0 585.0 361.0 650.0 468.0 571.0

41900 31400 34600 44100 36700 46800 38900 49600 42200 55100 50700 61100 10200 20700 22900 24000 26600 16400 27700 30500 26000 29600 34000 37000 28900 31600 39600 31400 34200 42900 33400 36900 46300 35800 39200 49700 38200 41900 53200 44000 57500 46700 59400 51900 65300 61100 74500

0.0144 0.0135 0.0135 0.0135 0.0127 0.0127 0.0120 0.0120 0.0183 0.0108 0.0096 0.0080 0.0423 0.0298 0.0300 0.0255 0.0255 0.0255 0.0222 0.0222 0.0180 0.0180 0.0176 0.0177 0.0148 0.0149 0.0147 0.0135 0.0137 0.0139 0.0126 0.0127 0.0128 0.0117 0.0118 0.0119 0.0110 0.0111 0.0112 0.0104 0.0106 0.0098 0.0099 0.0088 0.0089 0.0080 0.0066

0.0179 0.0170 0.0170 0.0168 0.0160 0.0159 0.0152 0.0150 0.0138 0.0136 0.0124 0.0105 0.0519 0.0365 0.0368 0.0314 0.0313 0.0278 0.0273 0.0274 0.0223 0.0223 0.0218 0.0218 0.0185 0.0186 0.0183 0.0170 0.0172 0.0173 0.0159 0.0159 0.0160 0.0149 0.0150 0.0150 0.0140 0.0140 0.0141 0.0133 0.0133 0.0126 0.0126 0.0115 0.0114 0.0105 0.0089

1130 1152 1159 1176 1202 1219 1243 1262 1323 1345 1420 1586 569 718 718 790 794 843 862 863 974 978 993 996 1095 1095 1111 1152 1150 1154 1206 1206 1210 1256 1256 1264 1306 1307 1316 1356 1363 1404 1415 1491 1507 1584 1768

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 419 20160520

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

ACSS/TW

CONSTRUCTION ACSS is a composite concentric-lay-stranded conductor. Steel strands form the central core of the conductor with one or more layers of 63% minimum average conductivity aluminum 1350-0 wire stranded around it. The steel core carries most or all of the mechanical load of the conductor due to the "0" (fully annealed or soft) temper aluminum. Steel core wires are protected from corrosion by a zinc-5% aluminum-mischmetal alloy coating. High strength steel core, aluminized, and aluminum clad steel core is also available. SPECIFICATIONS • B500 Metallic Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced. • B609 Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes. • B802 Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced. • B803 High-Strength Zinc-5% Aluminum-Mischmetal Alloy-Coated Steel Core Wire for Aluminum and Aluminum-Alloy Conductors, Steel Reinforced. • B856 Concentric-Lay-Stranded Aluminum Conductors, Coated Steel Supported (ACSS) • B857 Shaped Wire Compact Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Supported (ACSS/TW). NOTES 1)Data based on a nominal cable manufactured in accordance with ASTM B 857. 2)Resistance and ampacity based on an aluminum conductivity of 63% IACS at 20°C and a steel conductivity of 8% IACS at 20°C. 3)Ampacity based on referenced conductor temperature, 25°C ambient temperature, 2 ft/sec wind, in sun, with an emmisivity of 0.5 and a coefficient of solar absorption of 0.5, at sea level. 4)Rated breaking strength for standard core based on Class A zinc-5% aluminum-mischmetal alloy coated steel core wire in accordance with ASTM B 802. 5)Rated strength for high strength core based on Class A zinc-5% aluminum-mischmetal alloy coated high strength steel core wire in accordance with ASTM B 803. 6)The final design of a shaped wire compact conductor is contingent upon several factors such as: layer diameter, wire width and wire thickness. The actual configuration of a given size may vary between manufacturers. This may result in a slight variation in the number of wires, number of layers and dimensions of individual wires from that shown in the chart.

Item #

Linnet/ACSS/TW Oriole/ACSS/TW Flicker/ACSS/TW Hawk/ACSS/TW Hen/ACSS/TW Parakeet/ACSS/TW Dove/ACSS/TW

Size Type KCMIL No.

336.4 336.4 477.0 477.0 477.0 556.5 556.5

16 23 13 16 23 13 16

Cross Stranding Sectional Al/Total Layers No. x Dia./ (in)2 Wires St Wire 0.2641/0.3070 2 18 7 x 0.0884 0.2642/0.3258 2 16 7 x 0.1059 0.3747/0.4233 2 18 7 x 0.0940 0.3746/0.4356 2 18 7 x 0.1053 0.3747/0.4621 2 16 7 x 0.1261 0.4371/0.4937 2 18 7 x 0.1015 0.4371/0.5083 2 20 7 x 0.1138

Diameter Weight Rated Breaking (in) (lb/MFT) Strength (lb) St Complete Al St Total Standard High Ultra Core Cable High 0.2652 0.659 315.9 145.5 461.4 11200 12300 14400 0.3177 0.693 316.1 208.7 524.8 14800 16300 19100 0.2820 0.776 447.8 164.5 612.3 13000 14200 16400 0.3159 0.789 448.1 206.4 654.5 15600 17100 19800 0.3783 0.825 448.3 296.0 744.3 21000 22700 26700 0.3045 0.835 522.4 191.8 714.2 15200 16600 19100 0.3414 0.852 522.9 241.0 763.9 18200 19900 23100

Resistance (ohm/mile) DC AC 20°C 75°C 0.2588 0.3181 0.2565 0.3151 0.1831 0.2255 0.1825 0.2247 0.1809 0.2225 0.1569 0.1935 0.1564 0.1928

Ampacity (amps) 75°C 100°C 150°C 200°C 250°C 523 533 648 652 663 713 719

638 650 793 799 813 874 881

801 816 998 1005 1024 1102 1111

921 940 1151 1159 1181 1271 1282

1021 1043 1279 1289 1315 1415 1427

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

418 20140925

TRANSMISSION.& DISTRIBUTION CABLES

APPLICATIONS ACSS/TW is designed for overhead distribution and transmission lines. It is designed to operate continuously at elevated temperatures up to 250°C without loss of strength, it sags less under emergency electrical loadings than ACSR/TW, excellent self-damping properties, and its final sags are not affected by long-term creep of aluminum. ACSS/TW is available in equal area and equal diameter design. The equal area design allows equal ampacity in a smaller diameter conductor when compared with a standard ACSS conductor. The equal diameter design allows more ampacity in an equal diameter conductor when compared with a standard ACSS conductor. ACSS/TW also provides many design opportunities for new line construction: i.e., reduced tower cost, decreased sag, increased self-damping properties, increased operating temperature and improved corrosion resistance.

TRANSMISSION & DISTRIBUTION CABLES

ACSS/TW Item #

Size Type KCMIL No.

Rook/ACSS/TW Grosbeak/ACSS/TW Scoter/ACSS/TW Tern/ACSS/TW Puffin/ACSS/TW Condor/ACSS/TW Drake/ACSS/TW Canary/ACSS/TW Phoenix/ACSS/TW Rail/ACSS/TW Cardinal/ACSS/TW Snowbird/ACSS/TW Ortolan/ACSS/TW Curlew/ACSS/TW Avocet/ACSS/TW Bluejay/ACSS/TW Finch/ACSS/TW Oxbird/ACSS/TW Bunting/ACSS/TW Grackle/ACSS/TW Scissortail/ACSS/TW Bittern/ACSS/TW Pheasant/ACSS/TW Dipper/ACSS/TW Martin/ACSS/TW Bobolink/ACSS/TW Plover/ACSS/TW Lapwing/ACSS/TW Falcon/ACSS/TW Chukar/ACSS/TW Bluebird/ACSS/TW Mohawk/ACSS/TW Calumet/ACSS/TW Mystic/ACSS/TW Oswego/ACSS/TW Maumee/ACSS/TW Wabash/ACSS/TW Kettle/ACSS/TW Fraser/ACSS/TW Columbia/ACSS/TW Suwannee/ACSS/TW Cheyenne/ACSS/TW Genesee/ACSS/TW Hudson/ACSS/TW Catawba/ACSS/TW Nelson/ACSS/TW Yukon/ACSS/TW

636.0 636.0 636.0 795.0 795.0 795.0 795.0 900.0 954.0 954.0 954.0 1033.5 1033.5 1033.5 1113.0 1113.0 1113.0 1192.5 1192.5 1192.5 1272.0 1272.0 1272.0 1351.5 1351.5 1431.0 1431.0 1590.0 1590.0 1780.0 2156.0 571.7 565.3 666.6 664.8 768.2 762.8 957.2 946.7 966.2 959.6 1168.1 1158.0 1158.4 1272.0 1257.1 1233.6

13 16 23 7 11 13 16 13 5 7 13 5 7 13 5 7 13 5 7 13 5 7 13 7 13 7 13 7 13 8 8 13 16 13 16 13 16 7 10 13 16 5 7 13 5 7 13

Cross Stranding Sectional Al/Total Layers No. x Dia./ (in)2 Wires St Wire 0.4995/0.5643 0.4995/0.5808 0.4995/0.6160 0.6244/0.6675 0.6244/0.6919 0.6244/0.7053 0.6244/0.7261 0.7069/0.7983 0.7493/0.7876 0.7493/0.8011 0.7493/0.8464 0.8117/0.8534 0.8117/0.8678 0.8117/0.9169 0.8742/0.9191 0.8742/0.9347 0.8743/0.9852 0.9366/0.9848 0.9366/1.0013 0.9366/1.0554 0.9991/1.0505 0.9990/1.0681 0.9990/1.1256 1.0615/1.1348 1.0615/1.1959 1.1236/1.2017 1.1239/1.2664 1.2488/1.3351 1.2488/1.4071 1.3986/1.5126 1.6933/1.8309 0.4490/0.5074 0.4439/0.5162 0.5236/0.5914 0.5221/0.6072 0.6034/0.6819 0.5992/0.6966 0.7518/0.8038 0.7436/0.8168 0.7589/0.8573 0.7537/0.8762 0.9175/0.9646 0.9095/0.9733 0.9098/1.0281 0.9991/1.0505 0.9874/1.0557 0.9689/1.0925

2 2 2 2 2 2 2 2 3 3 2 3 3 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 2 2 2 2 2 2 3 3 2 2 3 3 2 3 3 3

18 20 18 17 18 20 20 20 30 32 20 30 32 20 30 33 38 30 34 38 30 35 39 35 42 36 44 36 42 37 64 18 20 20 20 20 20 32 35 21 22 30 33 25 30 35 38

7 x 0.1085 7 x 0.1216 7 x 0.1456 7 x 0.0886 7 x 0.1056 7 x 0.1213 7 x 0.1360 7 x 0.1291 7 x 0.0837 7 x 0.0971 7 x 0.1329 7 x 0.0871 7 x 0.1010 7 x 0.1383 7 x 0.0904 7 x 0.1049 19 x 0.0862 7 x 0.0936 7 x 0.1085 19 x 0.0892 7 x 0.0967 7 x 0.1121 19 x 0.0921 7 x 0.1155 19 x 0.0949 7 x 0.1189 19 x 0.0977 7 x 0.1253 19 x 0.1030 19 x 0.0874 19 x 0.0961 7 x 0.1030 7 x 0.1146 7 x 0.1111 7 x 0.1244 7 x 0.1195 7 x 0.1331 7 x 0.0973 7 x 0.1154 7 x 0.1338 7 x 0.1493 7 x 0.0926 7 x 0.1078 7 x 0.1467 7 x 0.0967 7 x 0.1115 19 x 0.0910

Diameter Weight Rated Breaking (in) (lb/MFT) Strength (lb) St Complete Al St Total Standard High Ultra Core Cable High 0.3255 0.3648 0.4368 0.2658 0.3168 0.3639 0.4080 0.3873 0.2511 0.2913 0.3987 0.2613 0.3030 0.4149 0.2712 0.3147 0.4310 0.2808 0.3255 0.4460 0.2901 0.3363 0.4605 0.3465 0.4745 0.3567 0.4885 0.3759 0.5150 0.4370 0.4805 0.3090 0.3441 0.3333 0.3732 0.3585 0.3993 0.2919 0.3462 0.4014 0.4479 0.2778 0.3234 0.4401 0.2901 0.3345 0.4550

0.890 0.908 0.953 0.960 0.980 0.993 1.010 1.055 1.044 1.061 1.084 1.089 1.102 1.129 1.129 1.143 1.185 1.167 1.181 1.225 1.203 1.220 1.264 1.256 1.300 1.291 1.337 1.358 1.408 1.445 1.608 0.846 0.858 0.913 0.927 0.977 0.990 1.060 1.077 1.092 1.108 1.155 1.165 1.196 1.203 1.213 1.245

597.0 597.6 597.6 745.2 745.9 746.3 747.0 844.9 897.7 898.6 895.5 972.5 972.5 970.1 1047 1048 1051 1122 1123 1126 1197 1198 1201 1273 1276 1347 1351 1498 1501 1675 2045 536.6 531.2 625.7 624.6 721.1 716.7 901.6 892.6 906.9 901.6 1099 1091 1087 1197 1184 1165

219.1 275.2 394.6 146.1 228.5 273.9 344.3 310.2 130.4 175.5 328.7 141.2 189.9 356.0 152.1 204.8 376.1 163.1 219.1 402.8 174 233.9 429.4 248.3 455.9 263.1 483.2 292.2 537 386.7 467.5 197.5 244.4 229.7 288.0 265.8 329.7 176.2 247.9 333.2 414.9 159.6 216.3 400.6 174.0 231.4 419.2

816.1 872.8 992.2 891.3 974.4 1020 1091 1155 1028 1074 1224 1114 1162 1326 1199 1253 1427 1285 1342 1529 1371 1432 1630 1521 1732 1611 1834 1790 2038 2062 2512 734.1 775.6 855.4 912.6 986.9 1046 1078 1141 1240 1317 1259 1307 1488 1371 1415 1584

17300 20700 27400 14200 17700 21700 25900 24600 14200 16700 26000 15400 18100 28200 16300 19500 30400 17500 20900 32600 18700 22300 34100 23700 36200 25100 38400 27900 42600 35300 42100 15600 18400 18200 21700 21000 24900 16800 21100 26400 30700 17200 20500 31100 18700 22100 33200

19000 22400 29700 15200 19200 23300 28000 26400 15200 18000 28000 16400 19500 30300 17500 21000 33200 18700 22500 35500 20000 24000 37300 25500 39600 27000 41900 29600 46600 38200 45500 17100 20200 19900 23400 23000 26800 18100 22900 28300 33100 18300 22100 33500 20000 23800 36300

Resistance (ohm/mile) DC AC 20°C 75°C

21900 26000 35000 17400 22000 26900 32600 30500 17100 20400 32300 18500 22000 35000 19500 23800 38700 20900 25400 41500 22300 27100 43000 28800 45600 30500 48300 33500 53700 43900 51700 19700 23500 22900 27200 26500 31200 20400 26200 32800 38600 20500 25000 38800 22300 26900 41900

0.1373 0.1369 0.1356 0.1105 0.1101 0.1098 0.1095 0.0970 0.0927 0.0926 0.0915 0.0856 0.0854 0.0845 0.0794 0.0793 0.0789 0.0741 0.0740 0.0737 0.0695 0.0694 0.0691 0.0653 0.0650 0.0617 0.0614 0.0555 0.0553 0.0495 0.0412 0.1527 0.1540 0.1310 0.1309 0.1137 0.1141 0.0922 0.0930 0.0904 0.0907 0.0757 0.0762 0.0754 0.0695 0.0702 0.0712

0.1696 0.1689 0.1672 0.1373 0.1365 0.1361 0.1355 0.1205 0.1187 0.1183 0.1138 0.1098 0.1095 0.1053 0.1022 0.1019 0.1010 0.0957 0.0954 0.0944 0.0900 0.0897 0.0887 0.0847 0.0837 0.0802 0.0793 0.0727 0.0717 0.0652 0.0543 0.1884 0.1898 0.1619 0.1616 0.1407 0.1411 0.1180 0.1187 0.1124 0.1127 0.0979 0.0981 0.0943 0.0900 0.0907 0.0914

Ampacity (amps) 75°C 100°C 150°C 200°C 250°C 775 781 795 878 886 890 896 962 967 972 997 1016 1021 1048 1063 1068 1084 1108 1114 1130 1152 1159 1176 1202 1220 1243 1263 1324 1346 1421 1601 725 725 798 802 872 873 973 974 1005 1008 1095 1094 1124 1152 1150 1154

951 958 976 1080 1090 1095 1103 1185 1189 1196 1229 1251 1257 1293 1310 1317 1336 1367 1374 1395 1423 1431 1452 1485 1508 1538 1562 1640 1668 1764 1999 889 890 980 985 1072 1074 1197 1199 1239 1243 1350 1350 1389 1423 1420 1425

1200 1210 1234 1366 1378 1386 1396 1501 1503 1512 1558 1584 1592 1641 1661 1669 1695 1735 1744 1771 1807 1817 1846 1888 1918 1958 1989 2092 2127 2255 2573 1121 1122 1238 1244 1356 1359 1514 1517 1571 1576 1712 1712 1766 1807 1804 1810

1386 1398 1427 1580 1595 1604 1616 1739 1740 1750 1806 1834 1843 1903 1925 1935 1965 2013 2023 2055 2098 2110 2143 2194 2228 2276 2313 2435 2477 2630 3014 1294 1295 1431 1439 1569 1573 1753 1756 1822 1828 1986 1985 2051 2098 2094 2101

1544 1557 1591 1762 1778 1789 1803 1942 1940 1953 2016 2048 2058 2126 2150 2161 2196 2249 2261 2298 2346 2360 2398 2455 2494 2549 2590 2730 2777 2952 3396 1441 1442 1595 1604 1750 1755 1955 1959 2035 2042 2219 2218 2295 2346 2342 2350

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 418 20140925

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

ACSS/TW Size Type KCMIL No.

Truckee/ACSS/TW 1372.5 Mackenzie/ACSS/TW 1359.7 Thames/ACSS/TW 1334.6 St. Croix/ACSS/TW 1467.8 Miramichi/ACSS/TW 1455.3 Merrimack/ACSS/TW 1433.6 Platte/ACSS/TW 1569.0 Potomac/ACSS/TW 1557.4 Rio Grande/ACSS/TW 1533.3 Schuylkill/ACSS/TW 1657.4 Pecos/ACSS/TW 1622.0 Pee Dee/ACSS/TW 1758.6 James/ACSS/TW 1730.6 Athabaska/ACSS/TW 1949.6 Cumberland/ACSS/TW 1926.9 Powder/ACSS/TW 2153.8 Santee/ACSS/TW 2627.3

5 7 13 5 7 13 5 7 13 7 13 7 13 7 13 8 8

Cross Stranding Sectional Al/Total Layers No. x Dia./ (in)2 Wires St Wire 1.0780/1.1334 1.0679/1.1418 1.0480/1.1809 1.1529/1.2124 1.1430/1.2222 1.1250/1.2677 1.2323/1.2957 1.2232/1.3079 1.2043/1.3571 1.3020/1.3920 1.2739/1.4429 1.3810/1.4770 1.3590/1.5314 1.5312/1.6377 1.5134/1.7049 1.6912/1.8290 2.0630/2.2268

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4

30 36 39 33 36 39 33 36 39 36 39 37 34 44 42 64 64

7 x 0.1004 7 x 0.1159 19 x 0.0944 7 x 0.1041 7 x 0.1200 19 x 0.0978 7 x 0.1074 7 x 0.1241 19 x 0.1012 7 x 0.1280 19 x 0.1064 7 x 0.1319 19 x 0.1075 7 x 0.1392 19 x 0.1133 19 x 0.0961 19 x 0.1062

Diameter Weight Rated Breaking (in) (lb/MFT) Strength (lb) St Complete Al St Total Standard High Ultra Core Cable High 0.3012 0.3477 0.4720 0.3123 0.3600 0.4890 0.3222 0.3723 0.5060 0.3840 0.5320 0.3957 0.5375 0.4176 0.5665 0.4805 0.5310

1.248 1.259 1.290 1.292 1.302 1.340 1.334 1.345 1.382 1.386 1.424 1.427 1.470 1.504 1.545 1.602 1.762

1292 1281 1260 1381 1372 1356 1478 1468 1449 1563 1533 1658 1636 1836 1819 2043 2492

187.6 250.0 451.1 201.7 268.0 434.0 215.0 287.0 519.0 305.0 574.0 324.0 585.0 360.7 649.8 467.5 570.9

1479 1531 1711 1583 1640 1840 1693 1755 1968 1868 2107 1982 2221 2197 2469 2510 3062

20200 23900 35800 21600 25600 38400 23100 27300 41200 29100 45000 30900 46400 34300 51600 42100 51300

21500 25700 39100 23100 27100 42000 24600 29000 45000 30900 49300 32800 50800 36500 56400 45500 55600

Resistance (ohm/mile) DC AC 20°C 75°C

24000 29000 45100 25800 30700 48400 27500 32800 51900 34900 56900 37100 58500 41300 65000 51700 63100

0.0644 0.0649 0.0658 0.0602 0.0607 0.0613 0.0564 0.0567 0.0573 0.0533 0.0541 0.0502 0.0508 0.0453 0.0456 0.0412 0.0338

0.0838 0.0842 0.0847 0.0787 0.0790 0.0791 0.0740 0.0741 0.0742 0.0700 0.0703 0.0663 0.0663 0.0595 0.0600 0.0543 0.0459

Ampacity (amps) 75°C 100°C 150°C 200°C 250°C 1206 1206 1210 1256 1269 1277 1319 1321 1329 1370 1377 1418 1430 1505 1508 1599 1784

1491 1490 1495 1554 1573 1584 1637 1639 1650 1702 1710 1763 1778 1873 1875 1996 2237

1896 1895 1902 1979 2007 2021 2092 2094 2108 2177 2187 2259 2277 2403 2400 2569 2894

2203 2202 2209 2302 2338 2354 2439 2441 2456 2539 2551 2637 2657 2808 2802 3009 3403

2466 2465 2472 2578 2577 2595 2692 2694 2710 2805 2816 2916 2937 3157 3148 3391 3846

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

418 20140925

TRANSMISSION.& DISTRIBUTION CABLES

Item #

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Solid Soft-Drawn Bare Aluminum Tie Wire TRANSMISSION.& DISTRIBUTION CABLES

Application To secure conductor to pin type insulators on a distribution line. Construction Bare aluminum EC grade solid conductor Standards ASTM B-230 Aluminum 1350-H19 Wire for electrical purposes Packaging 25lb coil, 50lb coil, coil boxes, spool or as required

Item #

ATW-6 ATW-4 ATW-2

Size

Weight /MFT (lb)

6 4 2

24.2 38.2 61.1

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

408 20140110

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Covered AL Line Wire Weatherproof

Construction Conductors are aluminum alloy 1350-H19, 6201-181, or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene (HD) or crosslinked polyethylene (XLP). Standards • ASTM B-230 Aluminum 1350-H19 Wire for Electrical Purposes • ASTM B-231 Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR). • ASTM B-1248 Polyethylene Plastics Molding and Extrusion Materials. • ASTM C-8.35 Specifications for Weather-Resistant Polethylene-Covered Wire and Cable. • ICEA S-70-547 Notes • The code words as given apply to conventional polyethylene line wire. • For 6201 aluminum conductors diameter equivalent to ACSR construction or 1350 aluminum equivalent. • Ampacity ratings based on 75°C conductor temperature, 25°C ambient temperature elevation – sea level. Emissivity 0.91 coefficient of absorption 0.95. Thermal reisitivity of covering -375°CCm2/Watt-CM. Wind speed 2ft/sec in sun. • To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.

Item #

AAC Apple Pear Apricot Peach Quince Orange Fig Olive Pomegranate Mulberry Anona Molles Huckleberry Paw Paw Breadfruit Persimmon Grapefruit

Size AWG or MCM

Strand

Insulation Thickness (mil)

Outside Diameter (in)

Rated Breaking Strength (lb)

XLP Weight /MFT (lb)

Poly Weight /MFT (lb)

XLP Ampacity

6 4 4 2 1/0 2/0 3/0 4/0 4/0 266.8 336.4 397.5 477.0 556.5 636.0 795.0 1033.5

Solid Solid 7/w 7/w 7/w 7/w 7/w 7/w 19/w 19/w 19/w 19/w 37/w 37/w 61/w 61/w 61/w

30 30 30 45 60 60 60 60 60 60 60 75 75 75 95 95 95

.222 .264 .285 .373 .477 .522 .570 .626 .632 .692 .766 .852 .921 .982 1.080 1.187 1.327

445 675 790 1220 1790 2260 2740 3450 3620 4470 5535 6400 7820 8950 10510 12900 16500

33.0 48.5 51.5 87.1 140.7 171.9 210.5 258.7 254.8 313.5 387.6 469.2 550.0 633.0 742.6 910.0 1156.7

32.0 47.3 50.8 84.0 135.6 166.2 204.0 251.4 247.9 305.8 378.8 457.4 537.5 619.4 724.7 890.0 1133.8

105 135 140 180 240 280 320 370 370 430 495 545 610 670 720 825 970

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

409 20140902

TRANSMISSION.& DISTRIBUTION CABLES

Applications Covered Line Wire is used primarily for overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.

TRANSMISSION & DISTRIBUTION CABLES

Covered AL Line Wire Weatherproof Item #

ACSR Walnut Butternut Hickory Pignut Beech Chestnut Almond Pecan Filbert Buckeye Hackberry 6201-T81 Hornbeam Linden Oilnut Waterash Shellbark Planetree

Size AWG or MCM

Strand

Insulation Thickness (mil)

Outside Diameter (in)

Rated Breaking Strength (lb)

XLP Weight /MFT (lb)

Poly Weight /MFT (lb)

XLP Ampacity

6 4 4 2 2 1 1/0 2/0 3/0 4/0 266.8

6/1 6/1 7/1 6/1 7/1 6/1 6/1 6/1 6/1 6/1 18/1

30 30 30 45 45 45 60 60 60 60 60

.258 .303 .309 .397 .405 .434 .506 .554 .607 .666 .711

1131 1170 2240 2710 3460 3370 4160 5040 6290 7930 6540

49 71.8 81.6 118.1 134.1 145.5 190.4 234.2 288.5 356.5 354.8

47 70.0 79.8 114.8 130.7 141.8 184.9 227.9 281.4 348.5 346.8

105 135 135 180 180 210 235 270 305 345 435

4 2 1/0 2/0 3/0 4/0

7/w 7/w 7/w 7/w 7/w 7/w

30 45 60 60 60 60

.310 .406 .518 .567 .622 .683

1480 2520 4010 4850 6110 7700

62.1 96.1 166.1 203.3 249.4 307.3

60.1 93.3 160.0 196.4 241.4 298.1

145 190 250 290 335 385

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 409 20140902

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Packaging Information ACSR and ACSR/AW Size Stranding Circular (ml or AWG)

Turkey

6

6/1

Swan

4

6/1

Swanate

4

7/1

Sparrow

2

6/1

Sparate

2

7/1

Robin

1

6/1

Raven

1/0

6/1

Quail

210

6/1

Pigeon

3/0

6/1

Penguin

4/0

6/1

Waxwing

266800

18/1

Owl Partridge Merlin

266800 266800 336400

6/7 26/7 18/1

Linnet

336400

26/7

Oriole

336400

30/7

Chickadee

397500

18/1

Brant

397500

24/7

Standard Packages Length Weight Reel (ft) (lb) Size

Code Word

5,400 16,340 3,835 15,420 3,580 17,910 8,955 2,410 19,390 9,695 6,465 2,250 11,250 5,625 1,910 15,380 7,690 5,125 1,515 12,180 6,090 4,060 9,660 4,830 3,220 7,670 3,835 2,555 6,080 3,040 2,025 14,370 7,185 4,555 10,330 11,390 5,695 16,410 8,205 9,430 9,430 9,640 9,640 4,820 12,790 6,395

Ibis

397500

26/7

Lark

397500

30/7

Pelican

477000

18/1

Flicker

477000

24/7

Hawk

477000

26/7

Hen

477000

30/7

Osprey

556500

18/1

Parakeet

556500

24/7

Dove

556500

26/7

Eagle

556500

30/7

Peacock

605000

24/7

Squab

605000

26/7

Teal

605000

30/19

Swift

636000

36/1

Kingbird

636000

18/1

Rook

636000

24/7

Grosbeak

636000

26/7

Egret

636000

30/19

195 590 220 885 240 1,200 600 220 1,700 885 590 240 1,200 600 220 1,770 885 590 220 1,770 885 590 1,770 885 590 1,770 885 590 1,770 885 590 4,160 2,080 1,560 3,795 4,160 2,080 7,590 3,795 4,970 4,970 4,160 4,160 2,080 6,550 3,275

Coil NR 30.22 Coil NR 36.22 Coil NR 38.22 NR 30.22 Coil NR 42.28 NR 36.22 NR 30.22 coji NR 38.22 NR 30.22 Coil NR 42.28 NR 36.22 NR 30.22 Coil NR 42.28 NR 36.22 NR 30.22 NR 42.28 NR 36.22 NR 30.22 NR 42.28 NR 36.22 NR 30.22 NR 42.28 NR 36.22 NR 30.22 NR 66.28 NR 48.28 NR 42.28 NR 60.28 NR 66.28 NR 48.28 RMT 84.36 NR 60.28 RM 66.32 NR 66.28 RM 66.32 NR 66.28 NR 48.28 RMT 84.36 NR 60.28

Size Stranding Circular (ml or AWG)

Standard Packages Length Weight Reel (ft) (lb) Size 13,890 6,945 7,980 7,980 8,030 8,030 4,015 10,660 5,330 11,570 5,785 6,650 6,650 6,890 6,890 3,445 9,140 4,570 9,910 4,955 5,700 5,700 8,400 4,200 9,120 4,560 10,490 5,245 5,245 6,025 6,025 4,015 6,020 6,020 4,515 3,010 8,000 4,000 8,670 4,335 9,980 4,990 4,990

7,590 3,795 4,970 4,970 4,160 4,160 2,080 6,550 3,275 7,590 3,795 4,970 4,970 4,160 4,160 2,080 6,550 3,275 7,590 3,795 4,970 4,970 6,550 3,275 7,590 3,795 9,860 4,930 4,930 3,880 3,880 2,585 4,160 4,160 3,120 2,080 6,550 3,275 7,590 3,795 9,860 4,930 4,930

RMT 84.36 NR 60.28 RM 66.32 NR 66.28 RM 66.32 NR 66.28 NR 48.28 RMT 84.36 NR 60.28 RMT 84.36 NR 60.28 RM 66.32 NR 66.28 RM 66.32 NR 66.28 NR 48.28 RMT 84.36 NR 60.28 RMT 84.36 NR 60.28 RM 66.32 NR 66.28 RMT 84.36 NR 60.28 RMT 84.36 NR 60.28 RMT 84.45 RM 66.32 NR 66.28 RM 66.32 NR 66.28 NR 60.28 RM 66.32 NR 66.28 NR 60.28 NR 48.28 RMT 84.36 NR 60.28 RMT 84.36 NR 60.28 RMT 84.45 RM 66.32 RM 66.28

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

410 20140921

TRANSMISSION.& DISTRIBUTION CABLES

Code Word

TRANSMISSION & DISTRIBUTION CABLES

Packaging Information ACSR and ACSR/AW Code Word

Size Stranding Circular (ml or AWG)

Flamingo

666600

24/7

Gannet

666600

26/7

Starling

715500

26/7

Redwing

715500

30/19

Coot

795000

36/1

Tern

795000

45/7

Cuckoo

795000

24/7

Condor

795000

54/7

Drake

795000

26/7

Mallard

795000

30/19

Ruddy

900000

45/7

Canary

900000

54/7

Catbird

954000

36/1

Rail

954000

45/7

Cardinal

954000

54/7

Ortolan

1033500

45/7

Curlew

1033500

54/7

Standard Packages Length Weight Reel (ft) (lb) Size

Code Word

11,440 7,630 3,815 12,410 8,270 4,135 11,560 7,710 3,855 8,880 4,440 4,440 9,640 4,820 4,820 12,000 6,000 4,000 9,600 6,400 3,200 11,520 5,760 10,400 6,940 3,470 7,980 3,990 3,990 10,590 5,295 10,180 5,090 8,030 4,015 4,015 14,990 9,990 4,995 9,600 4,800 13,850 9,230 4,615 8,870 4,435

Bluejay

1113000

45/7

Finch

1113000

54/19

Bunting

1192500

45/7

Grackle

1192500

54/19

Bittern

1272000

45/7

Pheasant

1272000

54/19

Dipper

1351500

45/7

Martin

1351500

54/19

Bobolink

1431000

45/7

Plover

1431000

54/19

Nuthatch

1510500

45/7

Parrot

1510500

54/19

Lapwing

1590000

45/7

Falcon

1590000

54/19

Chukar Bluebird Kiwi Thrasher

1780000 2156000 2167000 2312000

84/19 84/19 72/7 76/19

Joree

2515000

76/19

9,830 6,550 3,275 11,380 7,590 3,795 11,380 7,590 3,795 9,860 4,930 4,930 7,760 3,880 3,880 10,750 5,375 3,585 9,830 6,550 3,275 11,800 5,900 11,380 7,590 3,795 9,860 4,930 4,930 10,750 5,375 11,800 5,900 7,760 3,880 3,880 16,125 10,750 5,375 11,800 5,900 16,125 10,750 5,375 11,800 5,900

RMT 84.45 RMT 84.36 NR 60.28 RMT 90.45 RMT 84.36 NR 60.28 RMT 90.45 RMT 84.36 NR 66.28 RMT 84.45 RM 66.32 NR 66.28 RMT 84.45 RM 66.32 NR 66.28 RMT 90.45 RM 68.38 NR 60,28 RMT 90.45 RMT 84.36 NR 60.28 RMT 90.45 RM 68.38 RMT 90.45 RMT 84.36 NR 60.28 RMT 84.45 RM 66.32 NR 66.28 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 84.45 RM 66.32 NR 66.28 RMT 96.60 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 96.60 RW90.45 RM 68.38 RMT 90.45 RM 68.38

Size Stranding Circular (ml or AWG)

Standard Packages Length Weight Reel (ft) (lb) Size 12,850 8,570 4,285 2,855 8,190 4,095 12,000 8,000 4,000 7,650 3,825 11,245 7,500 3,750 7,170 3,585 10,585 7,060 3,530 6,750 3,375 10,000 6,660 3,335 6,370 3,185 9,470 6,310 3,155 6,040 3,020 9,000 6,000 3,000 5,730 2,865 9,200 7,500 7,000 9,500 6,940 8,730

16,125 10,750 5,375 3,585 11,720 5,860 16,125 10,750 5,375 11,720 5,860 16,125 10,750 5,375 11,720 5,860 16,125 10,750 5,375 11,720 5,860 16,125 10,750 5,375 11,720 5,860 16,125 10,750 5,375 11,720 5,860 16,125 10,750 5,375 11,720 5,860 19,080 18,830 16,120 24,000 17,530 24,000

RMT 96.60 RMT 90.45 RM 68.38 NR 60.28 RMT 90.45 RM 68.38 RMT 96.60 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 96.60 RMT90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 96.60 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 96.60 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 96.60 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 96.60 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 96.60 RMT 96.60 RMT 96.60 RMT 108.74 RMT 96.60 RMT 108.74

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 410 20140921

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Packaging Information ACSR and ACSR/AW

Petrel Minorca Leghorn Guinea Dotterel Dorking Brahma Cochin

Size Stranding Circular (ml or AWG) 101800 110800 134600 159000 176900 190800 203200 211300

12/7 12/7 12/7 12/7 12/7 12/7 16/19 12/7

TRANSMISSION.& DISTRIBUTION CABLES

Code Word

Standard Packages Length Weight Reel (ft) (lb) Size 12,500 11,480 9,450 8,000 7,195 6,665 7,875 6,020

3,175 3,175 3,175 3,175 3,175 3,175 5,330 3,175

NR 48.28 NR 48.28 NR 48.28 NR 48.28 NR 48.28 NR 48.28 NR 60.28 NR 48.28

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

410 20140921

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Packaging Information AAC Size Stranding Circular (ml or AWG)

Peachbell

6

7

Rose

4

7

Iris

2

7

Pansy

1

7

Poppy

1/0

7

Aster

2/0

7

Phlox

3/0

7

Oxlip

4/0

7

Sneezewort

250000

7

Valerian

250000

19

Daisy

266800

7

Laurel

266800

19

Peony

300000

19

Tulip

336400

19

Standard Packages Length Weight Reel (ft) (lb) Size

Code Word

56,910 28,455 8,130 35,710 17,855 5,100 22,470 11,235 3,210 17,830 8,915 2,550 14,130 7,065 2,020 11,210 5,605 8,890 4,445 7,050 3,525 5,970 2,985 16,190 16,190 8,095 5,590 2,795 15,170 15,170 7,585 13,490 13,490 6,745 12,030 12,030 6,015

Daffodil

350000

19

Canna

397500

19

Golden Tuft

450000

19

Cosmos

477000

19

Syringa

477000

37

Zinnia

500000

19

Hyacinth

500000

37

Dahlia

556500

19

Mistletoe

556500

37

Meadowsweet 600000

37

Orchid

636000

37

Heuchera

650000

37

1,400 700 200 1,400 700 200 1,400 700 200 1,400 700 200 1,400 700 200 1,400 700 1,400 700 1,400 700 1,400 700 3,800 3,800 1,900 1,400 700 3,800 3,800 1,900 3,800 3,800 1,900 3,800 3,800 1,900

NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 NR 42.28 NR 36.22 NR 42.28 NR 36.22 NR 42.28 NR 36.22 RM 66.32 NR 66.28 NR 48.28 NR 42.28 NR 36.22 RM 66.32 NR 66.28 NR 48.28 RM 66.32 NR 66.28 NR 48.28 RM 66.32 NR 66.28 NR 48.28

Size Stranding Circular (ml or AWG)

Standard Packages Length Weight Reel (ft) (lb) Size 11,560 11,560 5,780 10,180 10,180 5,090 9,000 9,000 4,500 8,490 8,490 4,245 16,530 8,265 8,265 8,100 8,100 4,050 15,760 7,880 7,880 7,270 7,270 3,635 14,170 7,085 7,085 13,140 6,570 6,570 12,400 6,200 6,200 12,130 6,065 6,065

3,800 3,800 1,900 3,800 3,800 1,900 3,800 3,800 1,900 3,800 3,800 1,900 7,400 3,700 3,700 3,800 3,800 1,900 7,400 3,700 3,700 3,800 3,800 1,900 7,400 3,700 3,700 7,400 3,700 3,700 7,400 3,700 3,700 7,400 3,700 3,700

RM 66.32 NR 66.28 NR 48.28 RM 66.32 NR 66.28 NR 48.28 RM 66.32 NR 66.28 NR 48.28 RM 66.32 NR 66.28 NR 48.28 RMT 84.45 NR 66.32 NR 66.28 RM 66.32 NR 66.28 NR 48.28 RMT 84.45 RM 66.32 NR 66.28 RM 66.32 NR 66.28 NR 48.28 RMT 84.45 RM 66.32 NR 66.28 RMT 84.45 RM 66.32 NR 66.28 RMT 84.45 RM 66.32 NR 66.28 RMT 84.45 RM 66.32 NR 66.28

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

411 20140921

TRANSMISSION.& DISTRIBUTION CABLES

Code Word

TRANSMISSION & DISTRIBUTION CABLES

Packaging Information AAC Code Word

Size Stranding Circular (mil) or AWG)

Verbena

700000

37

Flag

700000

61

Violet

715500

37

Nasturtium

715500

61

Petunia

750000

37

Cattail

750000

61

Arbutus

795000

37

Lilac

795000

61

Cockscomb

900000

37

Snapdragon

900000

61

Magnolia

954000

37

Goldenrod

954000

61

Standard Packages Length Weight Reel (ft) (lb) Size

Code Word

11,260 5,630 5,630 2,815 14,850 7,425 11,020 5,510 5,510 2,755 14,530 7,265 10,510 5,255 5,255 13,860 6,930 9,920 4,960 4,960 2,480 13,080 6,540 8,760 4,380 4,380 11,550 5,775 8,260 4,130 4,130 10,900 5,450

Hawkweed

1000000

37

Camellia

1000000

61

Bluebell

1033500

37

Larkspur

1033500

61

Marigold

1113000

61

Hawthorn

1192500

61

Narcissus

1272000

61

Columbine

1351500

61

Carnation

1431000

61

Gladiolus

1510500

61

Coreopsis

1590000

61

Jassamine Cowslip Sagebrush Lupine Bitterroot Trillium Bluebonnet

1750000 2000000 2250000 2500000 2750000 3000000 3500000

61 91 91 91 91 127 127

7,400 3,700 3,700 1,850 9,760 4,800 7,400 3,700 3,700 1,850 9,760 4,800 7,400 3,700 3,700 9,760 4,880 7,400 3,700 3,700 1,850 9,760 4,880 7,400 3,700 3,700 9,760 4,880 7,400 3,700 3,700 9,760 4,880

RMT 84.45 RM 66.32 NR 66.28 NR 48.28 RMT 90.45 RM 68.38 RMT 84.45 RM 66.32 NR 66.28 NR 48.28 RMT 90.45 RM 68.38 RMT 84.45 RM 66.32 NR 66.28 RMT 90.45 NR 68.38 RMT 84.45 RM 66.32 NR 66.28 NR 48.28 RMT 90.45 RM 68.38 RMT 84.45 RM 66.32 NR 66.28 RMT 90.45 RM 68.38 RMT 84.45 RM 66.32 NR 66.28 RMT 90.45 RM 68.38

Size Stranding Circular (mil) or AWG)

Standard Packages Length Weight Reel (ft) (lb) Size 7,880 3,940 3,940 10,400 5,200 7,630 3,815 3,815 10,060 5,030 9,430 4,670 8,720 4,360 8,170 4,085 7,690 3,845 7,270 3,635 6,880 3,440 6,540 3,270 5,940 4,850 4,270 3,840 3,490 3,350 2,840

7,400 3,700 3,700 9,760 4,880 7,400 3,700 3,700 9,760 4,880 9,760 4,880 9,760 4,880 9,760 4,880 9,760 4,880 9,760 4,880 9,760 4,880 9,760 4,880 9,760 9,100 9,100 9,100 9,100 9,530 9,530

RMT 84.45 RM 66.32 NR 66.28 RMT 90.45 NR 68.38 RMT 84.45 RM 66.32 NR 66.28 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT 90.45 RM 68.38 RMT90.45 RM 68.38 RMT90.45 RM 68.38 RMT 90.45 RMT 90.45 RMT 90.45 RMT 90.45 RMT 90.45 RMT 90.45 RMT 90.45

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 411 20140921

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Packaging Information AAAC 6201 Alloy Approx EC Size Cond. with Circular Equivalent (mil) Resistance

Akron

6

30580

Alton

4

48690

Ames

2

77470

Azusa

1/0

123300

Anaheim

2/0

155400

Amherst

3/0

195700

Alliance

4/0

246900

266.8

312800

Butte

Standard Packages Length Weight Reel (ft) (lb) Size

Code Word

48,780 24,390 6,970 30,630 15,315 4,375 19,260 9,630 2,750 12,100 6,050 1,730 9,600 4,800 7,600 3,810 6,040 3,020 12,940 12,940 6,470 4,315

Canton

336.4

394500

Cairo

397.5

465400

Darien

477.0

559500

Elgin

556.5

652400

Flint

636.0

740800

Greeley

795.0

927200

1,400 700 200 1,400 700 200 1,400 700 200 1,400 700 200 1,400 700 1,400 700 1,400 700 3,800 3,800 1,900 1,265

NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 Coil NR 42.28 NR 36.22 NR 42.28 NR 36.22 NR 42.28 NR 36.22 RM 66.32 NR 66.28 NR 48.28 NR 42.28

Note Length Tolerances: Standard lengths shown in these data are nominal. The allowable tolerance shall be plus or minus 5% for sizes larger than 77470 kcmil.

Approx EC Size Cond. with Circular Equivalent (mil) Resistance

Standard Packages Length Weight Reel (ft) (lb) Size 10,260 10,260 5,130 3,420 8,700 8,700 4,350 2,900 7,240 7,240 3,620 2,415 6,210 6,210 3,105 2,070 10,640 5,320 5,320 2,660 8,500 4,250 4,250 2,125

3,800 3,800 1,900 1,265 3,800 3,800 1,900 1,265 3,800 3,800 1,900 1,265 3,800 3,800 1,900 1,265 7,400 3,700 3,700 1,850 7,400 3,700 3,700 1,850

RM 66.32 NR 66.28 NR 48.28 NR 42.28 RM 66.32 NR 66.28 NR 48.28 NR 42.28 RM 66.32 NR 66.28 NR 48.28 NR 42.28 RM 66.32 NR 66.28 NR 48.28 NR 42.28 RMT 84.45 RM 66.32 NR 66.28 NR 48.28 RMT 84.45 RM 66.32 NR 66.28 NR 48.28

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 8Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

412 20140921

TRANSMISSION.& DISTRIBUTION CABLES

Code Word

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Packaging Information: TP Twisted Pair

Swallow TP

2x#3-6/1

Sparrow TP

2x#2-6/1

Robin TP

2x#1-6/1

Raven TP

2xl/0-6/1

Quail TP

2x2/0-6/1

Pigeon TP

2x3/0-6/1

Penguin TP

2x4/0-6/1

Waxwing TP

2x266.6-18/1

Partridge TP

2x266.8-26/7

Merlin TP

2x336.4-18/1

Linnet TP

Chickadee TP

2x336.4-26/7

2x397.5-18/1

Length (ft) 12205 24410 9650 19390 7685 15370 6050 12100 4825 9650 3825 7650 3025 6050 5375 7180 14360 5150 10300 3775 5650 11300 4050 8100 16200 4800 9600

Standard Packages Weight Reel (lb) Size 1770 3540 1770 3540 1770 3540 1770 3540 1770 3540 1770 3540 1770 3540 3115 4180 8320 3795 7590 2770 4180 8320 3785 7595 15180 4160 8320

48.28 NR 60.28 NR 48.28 NR 60.28NR 48.28 NR 60.28 NR 48.28 NR 60.28 NR 48.28 NR 60.28 NR 48.28 NR 60.28 NR 48.28 NR 66.28 NR 66.28NR 68.38 NR 90.45 RMT 66.28 NR 90.45 RMT 66.28 NR 68.38 NR 90.45 RMT 66.28 NR 90.45 RMT 96.60 RMT 68.38 RM 90.45 RMT

Bare Aluminum Cable ACSR ACSR/TP Code Size Word Circular (ml or AWG) Ptarmigan TP

2x397.5-20/7

lbis TP

2x397.5-26/7

Pelican TP

2x477.0-18/1

Tatler TP

2x477.0-20/7

Flicker TP

2x477.0-24/7

Hawk TP

2x477.0-26/7

Creeper TP

2x517.0-18/1

Osprey TP

2x556.5-18/1

Parakeet TP

2x556.5-24/7

Dove TP

2x556.5-26/7

Rook TP Drake TP

2x636.0-24/7 2x795.0-26/7

Tern TP

2x795.0-45/7

Bluejay TP

2x1113.0-45/7

Length (ft) 5400 10800 6925 13850 4000 8000 4450 8900 5330 10660 5750 11500 3710 7420 3425 6850 4570 9140 4950 9900 8000 3450 6900 4000 6000 5650

Standard Packages Weight Reel (lb) Size 4780 9570 7590 15180 4160 8320 4780 9570 6550 13100 7590 15180 4160 8320 4160 8320 6550 13100 7590 15180 13100 7590 15180 7170 10750 14180

84.36 RMT 90.45 RMT 84.45 RMT 96.60 RMT 68.38 RM 90.45 RMT 66.38 RM 90.45 RMT 84.45 RMT 96.60 RMT 84.45 RMT 96.60 RMT 68.38 RM 94.45 RMT 68.38 RM 90.45 RMT 68.38 RM 90.45 RMT 90.45 RMT 95.60 RMT 96.60 RMT 84.45 RMT 96.60 RMT 90.45 RMT 96.60 RMT 96.60 RMT

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

413 20140921

TRANSMISSION.& DISTRIBUTION CABLES

Bare Aluminum Cable ACSR ACSR/TP Code Size Word Circular (ml or AWG)

TRANSMISSION & DISTRIBUTION CABLES

Packaging Information: TP Twisted Pair Bare Aluminum Cable AAC AAC/TP Code Size Word Circular (ml or AWG) Lily TP

2x#3-7

Iris TP

2x#2-7

Pansy TP

2x#1-7

Poppy TP

2xl/0-7

Aster TP

2x2/0-7

Phlox TP

2x3/0-7

Oxlip TP

2x4/0-7

Valerian TP

2x250.0-19

Tulip TP

2x336.4-19

Canna TP

2x397.5-19

Cosmos TP

2x477.0-19

Dahlia TP

2x556.5-19

Length (ft) 7090 14180 28360 11250 21000 8915 17830 7050 14100 5600 11200 4450 9900 3550 7100 6800 16000 5300 6010 12020 4400 5090 10180 3600 4245 8490 3125 3635 7250

Standard Packages Weight Reel (lb) Size 700 1400 2800 1400 2615 1400 2800 1400 2800 1400 2800 1400 2800 1400 2800 3190 7510 3285 3800 7600 3280 3800 7600 3225 3800 7600 3265 3800 7600

42.24 NR 48.48 NR 60.28 NR 48.28 NR 60.28 NR 48.28 NR 66.28 NR 48.28 NR 66.28 NR 48.28 NR 66.28 NR 48.28 NR 66.28 NR 48.28 NR 66.28 NR 66.28 NR 84.36 RMT 66.28 NR 68.38 NR 84.36 RMT 66.28 NR 68.36 NR 84.36 RMT 66.28 NR 68.38 NR 90.45 NR 66.28 NR 68.38 NR 90.45 RMT

Bare Aluminum Cable AAC AAAC Alloy 3201/TP Code Size Word Circular (ml or AWG) Ames TP

2x#2-7

Azusa TP

2x1/0-7

Anaheim TP

2x2/0-7

Amherst TP

2x3/0 -7

Alliance TP

2x4/0-7

Butte TP

2x266.8-19

Length (ft) 9,700 19,400 6,050 12,100 4,800 9,600 3,810 7,625 3,020 6,040 6,475

Standard Packages Weight Reel (lb) Size 1,410 3,540 1,400 2,822 1,400 2,800 1,400 2,800 1,400 2,800 3,800

48.28 NR 60.28 NR 48.28 NR 60.28 NR 48.28 NR 66.28 NR 48.28 NR 66.28 NR 48.28 NR 66.28 NR 66.28 NR

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 413 20140921

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Packaging Information Covered Line Wire

Pear

Aluminum Conductors Standard Packages Size Stranding Length Poly XLP AWG (ft) Weight Weight (lb) (lb) 4

1

2,600 8,500

123 402

126 41

Coil NRC 30.18

AAC 1350-H19 Stranded Code Aluminum Conductors Standard Packages Word Size Stranding Length Poly XLP AWG or (ft) Weight Weight Cmils (lb) (lb) Apricot

4

7

Peach

2

7

Quince

1/0

7

Orange 210 Fig 3/0 Olive 4/0 Pomegranate 4/0 Mulberry 266800 Anona 336400 Molles 397500 Huckleberry 477000 Paw Paw 556500 Breadfruit 636000 Persimmon 795000 Grapefruit 1033500

7 7 7 19 19 19 19 37 37 61 61 61

2,500 7,000 1,500 7,500 1,000 4,700 3,750 4,400 3,500 3,800 3,000 2,400 2,000 3,300 2,800 2,500 2,200 1,700

127 356 126 630 136 637 623 898 880 942 917 909 915 1,774 1,463 1,812 1,958 1,927

129 361 131 653 141 661 645 926 905 968 941 930 938 1,815 1,772 1,857 2,002 1,966

Reel Size

Reel Size

Coil NRC 30.18 Coil NRC 36.24 Coil NRC 36.24 NRC 36.24 NRC 40.24 NRC 40.24 NRC 40.24 NRC 40.24 NRC 40.24 NRC 40.24 NRC 50.32 NRC 50.32 NRC 50.32 NRC 50.32 NRC 50.32

ACSR Code Word

Aluminum Conductors Standard Packages Size Stranding Length Poly XLP AWG or (ft) Weight Weight Cmils (lb) (lb)

Butternut

4

611

Hickory

4

7/1

Pignut

2

6/1

Beech

2

7/1

Chestnut

1

6/1

Almond

1/0

6/1

210 3/0 410 266800

6/1 6/1 6/1 18/1

Pecan Filbert Buckeye Hackberry

1,700 5,100 1,500 6,000 1,200 6,400 1,100 5,600 1,000 5,100 1,000 4,000 3,200 3,800 3,000 2,400

119 122 Coil 357 366 NRC 30.18 120 122 Coil 479 490 NRC 30.18 138 142 Coil 735 756 NRC 36.24 144 148 Coil 732 751 NRC 36.24 142 146 Coil 723 742 NRC 36.24 185 190 Coil 740 762 NRC 36.24 729 749 NRC 36.24 1,069 1,096 NRC 40.24 1,046 1,070 NRC 40.24 832 852 NRC 40.24

AAAC Alloy 6201-T81 Code Aluminum Conductors Standard Packages Word Size Stranding Length Poly XLP AWG or (ft) Weight Weight Cmils (lb) (lb) Hornbeam

48690

7

Linden

77470

7

Oilnut

123300

7

Waterash Shellbark Planetree

155400 195700 246900

7 7 71

1,700 5,100 1,200 6,400 1,000 4,000 3,200 3,800 3,000

Reel Size

102 307 112 597 160 640 628 917 894

106 317 115 615 166 664 651 948 922

Reel Size

Coil NRC 30.18 Coil NRC 36.24 Coil NRC 36.24 NRC 36.24 NRC 40.24 NRC 40.24

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

414 20140921

TRANSMISSION.& DISTRIBUTION CABLES

AAC Code Word

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

AAC 2 Layer 15kV • ASTM B230 Standard Specification for Aluminum 1350–H19 Wire for Electrical Purposes • ASTM B231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors • ASTM B232 Standard Specification for Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR) • ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for Electrical Purposes • ASTM B399 Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201T81 Conductors • ASTM B400 Standard Specification for Compact Round Concentric-Lay-Stranded Conductors • ASTM D2656 Standard Specification for Cross-linked Polyethylene Insulation for Wire and Cable Rated 2001 to 35 000 V • ASTM D1248 Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable • ICEA S-70-547 Standard Specification for Weather Resistant Polyethylene Covered Conductors

Construction Conductors are concentric strand AAC (1350H19), AAAC (either compressed or full compact depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical requirements of ICEA S-61-402. Available with track-resistant high-density polyethylene (TRHDPE) per ASTM D1248 or Track-Resistant Cross-linked Polyethylene (XLPE) covering per ASTM D2656. The minimum thickness of each layer at any point shall not be less than listed in the data table. The outer layer shall contain a carbon black additive, not less than 0.02% to provide the weather resistance, and track resistance.

Notes Full hardware solution is available, including spacers, brackets, installation tools and hardware. Please consult with AWG for more information.

Specification 15kV - 35kV Covered Aerial Medium Voltage Cable wire meets or exceeds all applicable ICEA specifications and the following ASTM specifications:

Item #

TW15-2-AAC-1/0-7 TW15-2-AAC-2/0-7 TW15-2-AAC-3/0-7 TW15-2-AAC-4/0-7 TW15-2-AAC-266.8-19 TW15-2-AAC-336.4-19 TW15-2-AAC-397.5-19 TW15-2-AAC-477-19 TW15-2-AAC-556.5-37 TW15-2-AAC-636-37

Size AWG or kcmil

Stranding

Conductor Diameter (mil)

Covering Thickness Inner Layer (mil)

Covering Thickness Outer Layer (mil)

Cable O.D. (mil)

Rated Strength (lb)

Weight (lb/MFT)

1/0 2/0 3/0 4/0 266.8 336.4 397.5 477 556.5 636

7 7 7 7 19 19 19 19 37 37

336 376 423 475 537 603 659 722 780 835

75 75 75 75 75 75 75 75 75 75

75 75 75 75 75 75 75 75 75 75

636 676 723 775 837 903 959 1022 1080 1135

1791 2259 2736 3447 4473 5535 6399 7524 8946 10260

196 230 272 325 387 466 535 623 708 794

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

420 20160208

TRANSMISSION.& DISTRIBUTION CABLES

Application Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

AAC 3 Layer 15kV-35kV

Construction Conductors are concentric strand AAC (1350H19), AAAC (either compressed or full compact depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical requirements of ICEA S-61-402. Available with track-resistant high-density polyethylene (TRHDPE) per ASTM D1248 or Track-Resistant Cross-linked Polyethylene (XLPE) covering per ASTM D2656. The minimum thickness of each layer at any point shall not be less than listed in the data table. The outer layer shall contain a carbon black additive, not less than 0.02% to provide the weather resistance, and track resistance. Specification 15kV - 35kV Covered Aerial Medium Voltage Cable wire meets or exceeds all applicable ICEA specifications and the following ASTM specifications:

Item #

15kV TW15-3-AAC-1/0-7 TW15-3-AAC-2/0-7 TW15-3-AAC-3/0-7 TW15-3-AAC-4/0-7 TW15-3-AAC-266.8-19 TW15-3-AAC-336.4-19 TW15-3-AAC-397.5-19 TW15-3-AAC-477-19 TW15-3-AAC-556.5-37 TW15-3-AAC-636-37 TW15-3-AAC-795-37

• ASTM B230 Standard Specification for Aluminum 1350–H19 Wire for Electrical Purposes • ASTM B231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors • ASTM B232 Standard Specification for Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR) • ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for Electrical Purposes • ASTM B399 Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201T81 Conductors • ASTM B400 Standard Specification for Compact Round Concentric-Lay-Stranded Conductors • ASTM D2656 Standard Specification for Cross-linked Polyethylene Insulation for Wire and Cable Rated 2001 to 35 000 V • ASTM D1248 Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable • ICEA S-70-547 Standard Specification for Weather Resistant Polyethylene Covered Conductors Notes Full hardware solution is available, including spacers, brackets, installation tools and hardware. Please consult with AWG for more information.

Size AWG or kcmil

Stranding

Conductor Diameter (mil)

Covering Thickness Conductor Shield (mil)

Covering Thickness Inner Layer (mil)

Covering Thickness Outer Layer (mil)

Cable O.D. (mil)

Rated Strength (lb)

Weight (lb/MFT)

1/0 2/0 3/0 4/0 266.8 336.4 397.5 477 556.5 636 795

7 7 7 7 19 19 19 19 37 37 37

336 376 423 475 537 603 659 722 780 835 932

15 15 15 15 15 15 15 15 20 20 20

75 75 75 75 75 75 75 75 75 80 80

75 75 75 75 75 75 75 75 75 80 80

666 706 753 805 867 933 989 1052 1120 1195 1292

1791 2259 2736 3447 4473 5535 6399 7524 8946 10260 12510

210 246 289 343 407 487 558 648 742 846 1020

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

421 20160208

TRANSMISSION.& DISTRIBUTION CABLES

Application Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.

TRANSMISSION & DISTRIBUTION CABLES

AAC 3 Layer 15kV-35kV Item #

25kV TW25-3-AAC-1/0-7 TW25-3-AAC-2/0-7 TW25-3-AAC-3/0-7 TW25-3-AAC-4/0-7 TW25-3-AAC-266.8-19 TW25-3-AAC-336.4-19 TW25-3-AAC-397.5-19 TW25-3-AAC-477-19 TW25-3-AAC-556.5-37 TW25-3-AAC-636-37 TW25-3-AAC-795-37 35kV TW35-3-AAC-1/0-7 TW35-3-AAC-2/0-7 TW35-3-AAC-3/0-7 TW35-3-AAC-4/0-7 TW35-3-AAC-266.8-19 TW35-3-AAC-336.4-19 TW35-3-AAC-397.5-19 TW35-3-AAC-477-19 TW35-3-AAC-556.5-37 TW35-3-AAC-636-37 TW35-3-AAC-795-37

Size AWG or kcmil

Stranding

Conductor Diameter (mil)

Covering Thickness Conductor Shield (mil)

Covering Thickness Inner Layer (mil)

Covering Thickness Outer Layer (mil)

Cable O.D. (mil)

Rated Strength (lb)

Weight (lb/MFT)

1/0 2/0 3/0 4/0 266.8 336.4 397.5 477 556.5 636 795

7 7 7 7 19 19 19 19 37 37 37

336 376 423 475 537 603 659 722 780 835 932

15 15 15 15 15 15 15 20 20 20 20

125 125 125 125 125 125 125 125 125 125 125

125 125 125 125 125 125 125 125 125 125 125

866 906 953 1005 1067 1133 1189 1262 1320 1375 1472

1791 2259 2736 3447 4473 5535 6399 7524 8946 10260 12510

309 350 400 460 531 621 698 806 899 995 1181

1/0 2/0 3/0 4/0 266.8 336.4 397.5 477 556.5 636 795

7 7 7 7 19 19 19 19 37 37 37

336 376 423 475 537 603 659 722 780 835 932

15 15 15 15 15 15 15 20 20 20 20

175 175 175 175 175 175 175 175 175 175 175

125 125 125 125 125 125 125 125 125 125 125

966 1006 1053 1105 1167 1233 1289 1362 1420 1475 1572

1791 2259 2736 3447 4473 5535 6399 7524 8946 10260 12510

368 411 464 527 603 696 777 889 987 1085 1278

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 421 20160208

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

AAC 3 Layer 35kV Electrical Properties

Construction Conductors are concentric strand AAC (1350H19), AAAC (either compressed or full compact depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical requirements of ICEA S-61-402. Available with track-resistant high-density polyethylene (TRHDPE) per ASTM D1248 or Track-Resistant Cross-linked Polyethylene (XLPE) covering per ASTM D2656. The minimum thickness of each layer at any point shall not be less than listed in the data table. The outer layer shall contain a carbon black additive, not less than 0.02% to provide the weather resistance, and track resistance. Specification 15kV - 35kV Covered Aerial Medium Voltage Cable wire meets or exceeds all applicable ICEA specifications and the following ASTM specifications: Item #

TW35-3-AAC-2-7 TW35-3-AAC-1/0-7 TW35-3-AAC-2/0-7 TW35-3-AAC-3/0-7 TW35-3-AAC-4/0-7 TW35-3-AAC-266.8-7 TW35-3-AAC-336.4-19 TW35-3-AAC-397.5-19 TW35-3-AAC-477-19 TW35-3-AAC-556.5-19 TW35-3-AAC-636-19 TW35-3-AAC-795-19 TW35-3-AAC-954-37 TW35-3-AAC-1033-37 TW35-3-AAC-636-37 TW35-3-AAC-795-37

Size Strands AC AC AC AWG or Resistance Resistance Resistance kcmil @25°C @75°C @90°C ohms/mile ohms/mile ohms/mile 2 1/0 2/0 3/0 4/0 266.8 336.4 397.5 477 556.5 636 795 954 1033 1272 1431

7 7 7 7 7 7 19 19 19 19 19 19 37 37 61 61

1.4020 0.8820 0.7000 0.5560 0.4410 0.3500 0.2780 0.2350 0.1970 0.1690 0.1490 0.1200 0.1010 0.0930 0.0770 0.0700

1.1810 1.0580 0.8390 0.6670 0.5290 0.4200 0.3330 0.2820 0.2360 0.2030 0.1790 0.1440 0.1210 0.1120 0.0930 0.0830

1.7640 1.1100 0.0881 0.6990 0.5550 0.4400 0.3500 0.2960 0.2480 0.2130 0.1870 0.1510 0.1270 0.1170 0.0970 0.0870

GMR (ft)

Inductive Reactance ohms/mile w/H-46D

Inductive Reactance ohms/mile w/H-35D

Inductive Reactance ohms/mile w/RTL-15

0.0088 0.0109 0.0122 0.0137 0.0154 0.0169 0.0200 0.0215 0.0239 0.0251 0.0274 0.0304 0.0328 0.0341 0.0385 0.0405

0.5691 0.5432 0.5295 0.5154 0.5012 0.4900 0.4695 0.4607 0.4479 0.4420 0.4313 0.4187 0.4095 0.4048 0.3901 0.3839

0.5763 0.5503 0.5366 0.5226 0.5084 0.4971 0.4767 0.4679 0.4550 0.4491 0.4385 0.4258 0.4166 0.4199 0.3972 0.3910

0.5252 0.4992 0.4855 0.4715 0.4573 0.4460 0.4256 0.4168 0.4039 0.3980 0.3874 0.3747 0.3655 0.3608 0.3461 0.3399

• ASTM B230 Standard Specification for Aluminum 1350–H19 Wire for Electrical Purposes • ASTM B231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors • ASTM B232 Standard Specification for Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR) • ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for Electrical Purposes • ASTM B399 Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201T81 Conductors • ASTM B400 Standard Specification for Compact Round Concentric-Lay-Stranded Conductors • ASTM D2656 Standard Specification for Cross-linked Polyethylene Insulation for Wire and Cable Rated 2001 to 35 000 V • ASTM D1248 Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable • ICEA S-70-547 Standard Specification for Weather Resistant Polyethylene Covered Conductors Notes Full hardware solution is available, including spacers, brackets, installation tools and hardware. Please consult with AWG for more information.

Inductive Inductive Impedance Impedance Impedance Reactance Reactance Z@75°C Z@75°C Z@75°C ohms/mile ohms/mile ohms/mile ohms/mile ohms/mile w/RTL-46 w/RTL-G095 H-46D H-35D RTL-15 0.5691 0.5432 0.5295 0.5154 0.5012 0.4900 0.4695 0.4607 0.4479 0.4420 0.4313 0.4187 0.4095 0.4048 0.3901 0.3839

0.5235 0.5975 0.5839 0.5698 0.5556 0.5443 0.5239 0.5151 0.5023 0.4963 0.4857 0.4731 0.4639 0.4591 0.4444 0.4383

1.7747 1.1889 0.9924 0.8427 0.7286 0.6451 0.5758 0.5401 0.5064 0.4862 0.4669 0.4427 0.4270 0.4200 0.4009 0.3928

1.7770 1.1921 0.9962 0.8470 0.7335 0.6505 0.5816 0.5462 0.5127 0.4927 0.4735 0.4495 0.4339 0.4268 0.4078 0.3998

1.7611 1.1694 0.9696 0.8165 0.6991 0.6124 0.5406 0.5031 0.4679 0.4466 0.4266 0.4014 0.3851 0.3778 0.3582 0.3500

Impedance Z@75°C ohms/mile RTL-46

Impedance Z@75°C ohms/mile RTL-G095

1.7747 1.1889 0.9924 0.8427 0.7286 0.6451 0.5758 0.5401 0.5064 0.4862 0.4669 0.4427 0.4270 0.4200 0.4009 0.3928

1.7929 1.2147 1.0224 0.8770 0.7670 0.6873 0.6209 0.5871 0.5550 0.5361 0.5175 0.4945 0.4794 0.4726 0.4540 0.4461

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

426 20160208

TRANSMISSION.& DISTRIBUTION CABLES

Application Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

SPACER CABLE TECHNICAL DATA FOR 3 LAYER COMPOUNDS

1 Color 2 Density (23℃) 3 Tensile strength before aging Elongation at break before aging 4 Performance after air oven aging Testing temperature Testing time Tensile strength variation before & after aging At-break-elongation variation before & after aging 5 Hot set test (0.2MPa, 200℃, 15min) Elongation under load Variation after cool 6 Volume resistivity at 20℃ 7 Volume resistivity at 90℃ 8 Volume resistivity at 90℃ (volume resistivity at 90℃, after air oven aging (100℃* 168 hours)) The second layer data (middle layer) 35kV XLPE, color natural (clear) DESCRIPTION 1 Color 2 Density (23℃) 3 Tensile strength before aging Elongation at break before aging 4 Performance after air oven aging Testing temperature Testing time Tensile strength variation before & after aging At-break-elongation variation before & after aging 5 Hot set test (0.2MPa, 200℃, 15min) Elongation under load Variation after cool 6 Dielectric loss factor , 20℃, 50Hz 7 Dielectric coefficient , 20℃, 50Hz 8 Volume resistivity at 20℃ 9 Dielectric strength

REQUIRED VALUE

g/cm3 Mpa %

Black 1.11 min 14 min 200

℃ hours % %

135±2 168 15 -7.5

% % Ω.cm Ω.cm

43 0 33 181

Ω.cm

124

UNIT

REQUIRED VALUE

g/cm3 Mpa %

clear, natural 0.926 min 23 min 500

℃ hours % %

135±2 168 -9.3 -17

% % Ω.m MV/m

35 0 0.0004 2.1 1.5x1013 35

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

427 20160216

TRANSMISSION.& DISTRIBUTION CABLES

The first layer data (inner layer) 35kV semi-conducting shield compound DESCRIPTION UNIT

TRANSMISSION & DISTRIBUTION CABLES

SPACER CABLE TECHNICAL DATA FOR 3 LAYER COMPOUNDS The third layer data (outer layer) 35kV XLPE, Gray, UV resistant, weather resistant DESCRIPTION UNIT REQUIRED VALUE 1 Color 2 Density (23℃) 3 Tensile strength before aging Elongation at break before aging 4 Performance after air oven aging Testing temperature Testing time Tensile strength variation before & after aging At-break-elongation variation before & after aging 5 Hot set test (0.2MPa, 200℃, 15min) Elongation under load Variation after cool 6 Dielectric loss factor, 20℃, 50Hz 7 Dielectric coefficient, 20℃, 50Hz 8 Volume resistivity at 20℃ 9 Dielectric strength

g/cm3 Mpa %

Gray 0.926 min 24.7 min 521

℃ hours % %

135±2 168 -7 -5

% % Ω.m MV/m

33 0 0.00005 2.0 1.4x1015 35

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 427 20160216

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

AAAC 2 Layer 15kV

Construction Conductors are concentric strand AAC (1350H19), AAAC (either compressed or full compact depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical requirements of ICEA S-61-402. Available with track-resistant high-density polyethylene (TRHDPE) per ASTM D1248 or Track-Resistant Cross-linked Polyethylene (XLPE) covering per ASTM D2656. The minimum thickness of each layer at any point shall not be less than listed in the data table. The outer layer shall contain a carbon black additive, not less than 0.02% to provide the weather resistance, and track resistance. Specification 15kV - 35kV Covered Aerial Medium Voltage Cable wire meets or exceeds all applicable ICEA specifications and the following ASTM specifications:

Item #

TW15-2-AAAC-48.69-7 TW15-2-AAAC-77.47-7 TW15-2-AAAC-123.3-7 TW15-2-AAAC-155.4-7 TW15-2-AAAC-195.7-7 TW15-2-AAAC-246.9-7 TW15-2-AAAC-312.8-19 TW15-2-AAAC-394.5-19 TW15-2-AAAC-465.4-19 TW15-2-AAAC-559.5-19 TW15-2-AAAC-652.4-19 TW15-2-AAAC-740.8-37

• ASTM B230 Standard Specification for Aluminum 1350–H19 Wire for Electrical Purposes • ASTM B231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors • ASTM B232 Standard Specification for Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR) • ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for Electrical Purposes • ASTM B399 Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201T81 Conductors • ASTM B400 Standard Specification for Compact Round Concentric-Lay-Stranded Conductors • ASTM D2656 Standard Specification for Cross-linked Polyethylene Insulation for Wire and Cable Rated 2001 to 35 000 V • ASTM D1248 Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable • ICEA S-70-547 Standard Specification for Weather Resistant Polyethylene Covered Conductors Notes Full hardware solution is available, including spacers, brackets, installation tools and hardware. Please consult with AWG for more information.

Size AWG or kcmil

Equivalent AAC AWG or kcmil

Stranding

Conductor Diameter (mil)

Covering Thickness Inner Layer (mil)

Covering Thickness Outer Layer (mil)

Cable O.D. (mil)

Rated Strength (lb)

Weight (lb/MFT)

48.69 77.47 123.3 155.4 195.7 246.9 312.8 394.5 465.4 559.5 652.4 740.8

4 2 1/0 2/0 3/0 4/0 266.8 336.4 397.5 477 556.5 636

7 7 7 7 7 7 19 19 19 19 19 37

250 316 398 447 502 563 642 720 782 858 927 990

75 75 75 75 75 75 75 75 75 75 75 80

75 75 75 75 75 75 75 75 75 75 75 80

550 616 698 747 802 863 942 1020 1082 1158 1227 1310

1584 2520 4014 4851 6111 7704 9900 11970 14040 16920 19710 21960

124 165 225 265 314 376 450 543 623 727 828 938

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

422 20160108

TRANSMISSION.& DISTRIBUTION CABLES

Application Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

AAAC 3 Layer 15k-35kV

Construction Conductors are concentric strand AAC (1350H19), AAAC (either compressed or full compact depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical requirements of ICEA S-61-402. Available with track-resistant high-density polyethylene (TRHDPE) per ASTM D1248 or Track-Resistant Cross-linked Polyethylene (XLPE) covering per ASTM D2656. The minimum thickness of each layer at any point shall not be less than listed in the data table. The outer layer shall contain a carbon black additive, not less than 0.02% to provide the weather resistance, and track resistance. Specification 15kV - 35kV Covered Aerial Medium Voltage Cable wire meets or exceeds all applicable ICEA specifications and the following ASTM specifications: Item #

15kV TW15-3-AAAC-48.69-7 TW15-3-AAAC-77.47-7 TW15-3-AAAC-123.3-7 TW15-3-AAAC-155.4-7 TW15-3-AAAC-195.7-7 TW15-3-AAAC-246.9-7 TW15-3-AAAC-312.8-19 TW15-3-AAAC-394.5-19 TW15-3-AAAC-465.4-19 TW15-3-AAAC-559.5-19 TW15-3-AAAC-652.4-19 TW15-3-AAAC-740.8-37

Size AWG or kcmil

Equivalent AAC AWG or kcmil

Stranding

48.69 77.47 123.3 155.4 195.7 246.9 312.8 394.5 465.4 559.5 652.4 740.8

4 2 1/0 2/0 3/0 4/0 266.8 336.4 397.5 477 556.5 636

7 7 7 7 7 7 19 19 19 19 19 37

• ASTM B230 Standard Specification for Aluminum 1350–H19 Wire for Electrical Purposes • ASTM B231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors • ASTM B232 Standard Specification for Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR) • ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for Electrical Purposes • ASTM B399 Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201T81 Conductors • ASTM B400 Standard Specification for Compact Round Concentric-Lay-Stranded Conductors • ASTM D2656 Standard Specification for Cross-linked Polyethylene Insulation for Wire and Cable Rated 2001 to 35 000 V • ASTM D1248 Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable • ICEA S-70-547 Standard Specification for Weather Resistant Polyethylene Covered Conductors Notes Full hardware solution is available, including spacers, brackets, installation tools and hardware. Please consult with AWG for more information.

Conductor Covering Covering Covering Diameter Thickness Thickness Thickness (mil) Conductor Inner Outer Shield Layer Layer (mil) (mil) (mil) 250 316 398 447 502 563 642 720 783 858 927 990

15 15 15 15 15 15 15 15 15 15 20 20

75 75 75 75 75 75 75 75 75 75 75 75

75 75 75 75 75 75 75 75 75 75 75 75

Cable O.D. (mil)

Rated Strength (lb)

Weight (lb/MFT)

580 646 728 777 832 893 972 1050 1113 1188 1267 1330

1584 2520 4014 4851 6111 7704 9900 11970 14040 16920 19710 21960

137 179 241 283 334 397 473 568 649 755 894 963

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

423 20160208

TRANSMISSION.& DISTRIBUTION CABLES

Application Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.

TRANSMISSION & DISTRIBUTION CABLES

AAAC 3 Layer 15k-35kV Item #

25kV TW25-3-AAAC-48.69-7 TW25-3-AAAC-77.47-7 TW25-3-AAAC-123.3-7 TW25-3-AAAC-155.4-7 TW25-3-AAAC-195.7-7 TW25-3-AAAC-246.9-7 TW25-3-AAAC-312.8-19 TW25-3-AAAC-394.5-19 TW25-3-AAAC-465.4-19 TW25-3-AAAC-559.5-19 TW25-3-AAAC-652.4-19 TW25-3-AAAC-740.8-37 TW25-3-AAAC-927.2-37 35kV TW35-3-AAAC-48.69-7 TW35-3-AAAC-77.47-7 TW35-3-AAAC-123.3-7 TW35-3-AAAC-155.4-7 TW35-3-AAAC-195.7-7 TW35-3-AAAC-246.9-7 TW35-3-AAAC-312.8-19 TW35-3-AAAC-394.5-19 TW35-3-AAAC-465.4-19 TW35-3-AAAC-559.5-19 TW35-3-AAAC-652.4-19

Size AWG or kcmil

Equivalent AAC AWG or kcmil

Stranding

Conductor Covering Covering Covering Diameter Thickness Thickness Thickness (mil) Conductor Inner Outer Shield Layer Layer (mil) (mil) (mil)

48.69 77.47 123.3 155.4 195.7 246.9 312.8 394.5 465.4 559.5 652.4 740.8 927.2

4 2 1/0 2/0 3/0 4/0 266.8 336.4 397.5 477 556.5 636 795

7 7 7 7 7 7 19 19 19 19 19 37 37

250 316 398 447 502 563 642 720 783 858 927 990 1108

15 15 15 15 15 15 15 15 15 20 20 20 20

125 125 125 125 125 125 125 125 125 125 125 125 125

48.69 77.47 123.3 155.4 195.7 246.9 312.8 394.5 465.4 559.5 652.4

4 2 1/0 2/0 3/0 4/0 266.8 336.4 397.5 477 556.5

7 7 7 7 7 7 19 19 19 19 19

250 316 398 447 502 563 642 720 783 858 927

15 15 15 15 15 15 15 15 15 20 20

175 175 175 175 175 175 175 175 175 175 175

Cable O.D. (mil)

Rated Strength (lb)

Weight (lb/MFT)

125 125 125 125 125 125 125 125 125 125 125 125 125

780 846 928 977 1032 1093 1172 1251 1313 1398 1467 1530 1648

1584 2520 4014 4851 6111 7704 9900 11970 14040 16920 19710 21960 27450

225 275 348 396 454 525 611 716 805 932 1044 1148 1389

125 125 125 125 125 125 125 125 125 125 125

880 946 1028 1077 1132 1193 1272 1351 1412 1498 1567

1584 2520 4014 4851 6111 7704 9900 11970 14040 16920 19710

278 333 411 462 523 598 689 799 892 1024 1141

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 423 20160208

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

ACSR 2 Layer 15kV • ASTM B230 Standard Specification for Aluminum 1350–H19 Wire for Electrical Purposes • ASTM B231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors • ASTM B232 Standard Specification for Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR) • ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for Electrical Purposes • ASTM B399 Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201T81 Conductors • ASTM B400 Standard Specification for Compact Round Concentric-Lay-Stranded Conductors • ASTM D2656 Standard Specification for Cross-linked Polyethylene Insulation for Wire and Cable Rated 2001 to 35 000 V • ASTM D1248 Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable • ICEA S-70-547 Standard Specification for Weather Resistant Polyethylene Covered Conductors

Construction Conductors are concentric strand AAC (1350H19), AAAC (either compressed or full compact depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical requirements of ICEA S-61-402. Available with track-resistant high-density polyethylene (TRHDPE) per ASTM D1248 or Track-Resistant Cross-linked Polyethylene (XLPE) covering per ASTM D2656. The minimum thickness of each layer at any point shall not be less than listed in the data table. The outer layer shall contain a carbon black additive, not less than 0.02% to provide the weather resistance, and track resistance.

Notes Full hardware solution is available, including spacers, brackets, installation tools and hardware. Please consult with AWG for more information.

Specification 15kV - 35kV Covered Aerial Medium Voltage Cable wire meets or exceeds all applicable ICEA specifications and the following ASTM specifications:

Item #

TW15-2-ACSR-4-6/1 TW15-2-ACSR-2-6/1 TW15-2-ACSR-1/0-6/1 TW15-2-ACSR-2/0-6/1 TW15-2-ACSR-3/0-6/1 TW15-2-ACSR-4/0-6/1 TW15-2-ACSR-266.8-18/1 TW15-2-ACSR-266.8-26/7 TW15-2-ACSR-336.4-18/1 TW15-2-ACSR-336.4-26/7 TW15-2-ACSR-336.4-30/7 TW15-2-ACSR-397.5-18/1 TW15-2-ACSR-397.5-24/7 TW15-2-ACSR-397.5-26/7

Size AWG or kcmil

Stranding

Conductor Diameter (mil)

Covering Thickness Inner Layer (mil)

Covering Thickness Outer Layer (mil)

Cable O.D. (mil)

Rated Strength (lb)

Weight (lb/MFT)

4 2 1/0 2/0 3/0 4/0 266.8 266.8 336.4 336.4 336.4 397.5 397.5 397.5

6/1 6/1 6/1 6/1 6/1 6/1 18/1 26/7 18/1 26/7 30/7 18/1 24/7 26/7

250 316 398 447 502 563 609 642 684 720 741 743 772 783

75 75 75 75 75 75 75 75 75 75 75 75 75 75

75 75 75 75 75 75 75 75 75 75 75 75 75 75

550 616 698 747 802 863 909 942 984 1020 1041 1043 1072 1083

1767 2708 4161 5045 6289 7933 6536 10735 8246 13395 16435 9443 13870 1545

136 184 255 303 362 432 441 452 536 555 621 611 609 645

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

424 20160208

TRANSMISSION.& DISTRIBUTION CABLES

Application Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.

TRANSMISSION & DISTRIBUTION CABLES

ACSR 2 Layer 15kV Item #

TW15-2-ACSR-477-24/7 TW15-2-ACSR-477-26/7 TW15-2-ACSR-477-30/7 TW15-2-ACSR-556.5-18/1 TW15-2-ACSR-556.5-24/7 TW15-2-ACSR-556.5-26/7 TW15-2-ACSR-636-18/1 TW15-2-ACSR-636-24/7 TW15-2-ACSR-636-26/7 TW15-2-ACSR-795-26/7 TW15-2-ACSR-795-45/7

Size AWG or kcmil

Stranding

Conductor Diameter (mil)

Covering Thickness Inner Layer (mil)

Covering Thickness Outer Layer (mil)

Cable O.D. (mil)

Rated Strength (lb)

Weight (lb/MFT)

477 477 477 556.5 556.5 556.5 636 636 636 795 795

24/7 26/7 30/7 18/1 24/7 26/7 18/1 24/7 26/7 26/7 45/7

846 858 883 879 914 927 940 977 990 1108 1063

75 75 75 75 75 75 75 75 75 80 80

75 75 75 75 75 75 75 75 75 80 80

1146 1158 1183 1179 1214 1227 1240 1277 1290 1428 1383

16340 18525 22610 13015 18810 21470 14915 20900 23940 29925 20995

719 762 854 813 828 878 912 936 993 1234 1031

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 424 20160208

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

ACSR 3 Layer 15kV-35kV

Construction Conductors are concentric strand AAC (1350H19), AAAC (either compressed or full compact depending on conductor size) or ACSR. The conductor shield shall be an extruded back semiconductor polymer meeting the physical requirements of ICEA S-61-402. Available with track-resistant high-density polyethylene (TRHDPE) per ASTM D1248 or Track-Resistant Cross-linked Polyethylene (XLPE) covering per ASTM D2656. The minimum thickness of each layer at any point shall not be less than listed in the data table. The outer layer shall contain a carbon black additive, not less than 0.02% to provide the weather resistance, and track resistance. Specification 15kV - 35kV Covered Aerial Medium Voltage Cable wire meets or exceeds all applicable ICEA specifications and the following ASTM specifications: Item #

15kV TW15-3-ACSR-4-6/1 TW15-3-ACSR-2-6/1 TW15-3-ACSR-1/0-6/1 TW15-3-ACSR-2/0-6/1 TW15-3-ACSR-3/0-6/1 TW15-3-ACSR-4/0-6/1 TW15-3-ACSR-266.8-18/1 TW15-3-ACSR-266.8-26/7 TW15-3-ACSR-336.4-18/1 TW15-3-ACSR-336.4-26/7 TW15-3-ACSR-336.4-30/7 TW15-3-ACSR-397.5-18/1 TW15-3-ACSR-397.5-24/7 TW15-3-ACSR-397.5-26/7 TW15-3-ACSR-477-24/7

• ASTM B230 Standard Specification for Aluminum 1350–H19 Wire for Electrical Purposes • ASTM B231 Standard Specification for Concentric-Lay-Stranded Aluminum 1350 Conductors • ASTM B232 Standard Specification for Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR) • ASTM B398 Standard Specification for Aluminum-Alloy 6201-T81 and 6201-T83 Wire for Electrical Purposes • ASTM B399 Standard Specification for Concentric-Lay-Stranded Aluminum-Alloy 6201T81 Conductors • ASTM B400 Standard Specification for Compact Round Concentric-Lay-Stranded Conductors • ASTM D2656 Standard Specification for Cross-linked Polyethylene Insulation for Wire and Cable Rated 2001 to 35 000 V • ASTM D1248 Standard Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable • ICEA S-70-547 Standard Specification for Weather Resistant Polyethylene Covered Conductors Notes Full hardware solution is available, including spacers, brackets, installation tools and hardware. Please consult with AWG for more information.

Size AWG or kcmil

Stranding

Conductor Diameter (mil)

Covering Thickness Conductor Shield (mil)

Covering Thickness Inner Layer (mil)

Covering Thickness Outer Layer (mil)

Cable O.D. (mil)

Rated Strength (lb)

Weight (lb/MFT)

4 2 1/0 2/0 3/0 4/0 266.8 266.8 336.4 336.4 336.4 397.5 397.5 397.5 477

6/1 6/1 6/1 6/1 6/1 6/1 18/1 26/7 18/1 26/7 30/7 18/1 24/7 26/7 24/7

250 316 398 447 502 563 609 642 684 720 741 743 772 783 846

15 15 15 15 15 15 15 15 15 15 15 15 15 15 15

75 75 75 75 75 75 75 75 75 75 75 75 75 75 75

75 75 75 75 75 75 75 75 75 75 75 75 75 75 75

580 646 728 777 832 893 939 972 1014 1050 1071 1073 1102 1113 1176

1767 2708 4161 5045 6289 7933 6536 10735 8246 13395 16435 9443 13870 15485 16340

151 202 278 330 393 471 474 553 570 669 935 653 707 770 824

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

425 20160208

TRANSMISSION.& DISTRIBUTION CABLES

Application Used for primary and secondary overhead distribution where limited space is available or desirable for rights of way. Installed as an uninsulated conductor; however, covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other objects contact conductors in such close proximity. The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation; particularly useful in congested areas such as alleyways or tight corridors.

TRANSMISSION & DISTRIBUTION CABLES

ACSR 3 Layer 15kV-35kV Item #

Size AWG or kcmil

Stranding

Conductor Diameter (mil)

Covering Thickness Conductor Shield (mil)

Covering Thickness Inner Layer (mil)

Covering Thickness Outer Layer (mil)

Cable O.D. (mil)

Rated Strength (lb)

Weight (lb/MFT)

TW15-3-ACSR-477-26/7 TW15-3-ACSR-477-30/7 TW15-3-ACSR-556.5-18/1 TW15-3-ACSR-556.5-24/7 TW15-3-ACSR-556.5-26/7 TW15-3-ACSR-636-18/1 TW15-3-ACSR-636-26/7 25kV TW25-3-ACSR-1/0-6/1 TW25-3-ACSR-2/0-6/1 TW25-3-ACSR-3/0-6/1 TW25-3-ACSR-4/0-6/1 TW25-3-ACSR-266.8-18/1 TW25-3-ACSR-266.8-26/7 TW25-3-ACSR-336.4-18/1 TW25-3-ACSR-336.4-26/7 TW25-3-ACSR-336.4-30/7 TW25-3-ACSR-397.5-18/1 TW25-3-ACSR-397.5-24/7 TW25-3-ACSR-397.5-26/7 TW25-3-ACSR-477-24/7 TW25-3-ACSR-477-26/7 TW25-3-ACSR-477-30/7 TW25-3-ACSR-556.5-18/1 TW25-3-ACSR-556.5-24/7 TW25-3-ACSR-556.5-26/7 35kV TW35-3-ACSR-1/0-6/1 TW35-3-ACSR-2/0-6/1 TW35-3-ACSR-4/0-6/1 TW35-3-ACSR-266.8-18/1 TW35-3-ACSR-266.8-26/7 TW35-3-ACSR-336.4-18/1 TW35-3-ACSR-336.4-26/7 TW35-3-ACSR-336.4-30/7 TW35-3-ACSR-397.5-18/1 TW35-3-ACSR-397.5-24/7 TW35-3-ACSR-397.5-26/7 TW35-3-ACSR-477-24/7 TW35-3-ACSR-477-26/7 TW35-3-ACSR-477-30/7 TW35-3-ACSR-556.5-18/1 TW35-3-ACSR-556.5-24/7 TW35-3-ACSR-556.5-26/7 TW35-3-ACSR-636-18/1 TW35-3-ACSR-636-26/7 TW35-3-ACSR-795-26/7 TW35-3-ACSR-795-45/7

477 477 556.5 556.5 556.5 636 636

26/7 30/7 18/1 24/7 26/7 18/1 26/7

858 883 879 914 927 940 990

15 15 20 20 20 20 20

75 75 75 75 75 75 75

75 75 75 75 75 75 75

1188 1213 1219 1254 1267 1280 1330

18525 22610 13015 18810 21470 14915 23940

899 1274 874 949 1036 1200 1373

1/0 2/0 3/0 4/0 266.8 266.8 336.4 336.4 336.4 397.5 397.5 397.5 477 477 477 556.5 556.5 556.5

6/1 6/1 6/1 6/1 18/1 26/7 18/1 26/7 30/7 18/1 24/7 26/7 24/7 26/7 30/7 18/1 24/7 26/7

398 447 502 563 609 642 684 720 741 743 772 783 846 858 883 879 914 927

15 15 15 15 15 15 15 15 15 15 15 15 20 20 20 20 20 20

125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125

125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125

928 977 1032 1093 1139 1172 1214 1250 1271 1273 1302 1313 1386 1398 1423 1419 1454 1467

4161 5045 6289 7933 6536 10735 8246 13395 16435 9443 13870 15485 16340 18525 22610 13015 18810 21470

385 443 513 600 608 692 714 818 1086 804 863 926 999 1076 1458 1045 1124 1213

1/0 2/0 4/0 266.8 266.8 336.4 336.4 336.4 397.5 397.5 397.5 477 477 477 556.5 556.5 556.5 636 636 795 795

6/1 6/1 6/1 18/1 26/7 18/1 26/7 30/7 18/1 24/7 26/7 24/7 26/7 30/7 18/1 24/7 26/7 18/1 26/7 26/7 45/7

398 447 563 609 642 684 720 741 743 772 783 846 858 883 879 914 927 940 990 1107 1063

15 15 15 15 15 15 15 15 15 15 15 20 20 20 20 20 20 20 20 20 20

175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175

125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125

1028 1077 1193 1239 1272 1314 1350 1371 1373 1402 1413 1486 1498 1523 1519 1554 1567 1580 1630 1747 1703

4161 5045 7933 6536 10735 8246 13395 16435 9443 13870 15485 16340 18525 22610 13015 18810 21470 14915 23940 29925 20995

448 509 673 684 770 794 901 1170 889 949 1013 1091 1168 1552 1138 1220 1309 1637 1826 2146 1892

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 425 20160208

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Covered CU Line Wire Weatherproof

Application Primary and secondary distribution on pole lines, service from pole to weatherhead, distribution infoors and out. Mining, industrial, railroad and other application. Specification • ASTM B1 Hard-Drawn Copper Wire • ASTM B2 Medium-Hard-Drawn Copper WIre • ASTM B3 Soft or Annealed Copper Wire • ASTM B4 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft • ASTM D-1248 Polyethylene Plastics, Molding and Extrusion Materials • ANSI C-8.35 Specifications for Weather-Resistant Polyethylene-Covered Wire and Cable

Item #

Size

Stranding

Insulation Thickness (in)

Poly Weight /MFT (lb)

XLP Weight /MFT (lb)

14S-01WP 12S-01WP 10S-01WP 9S-01WP 8S-01WP 6S-01WP 4S-01WP 3S-01WP 2S-01WP 1S-01WP 1/0S-01WP 2/0S-01WP 6-01WP-7 4-01WP-7 2-01WP-7 1-01WP-7 1/0-01WP-7 1/0-01WP-19 2/0-01WP-7 2/0-01WP-19 3/0-01WP-7 3/0-01WP-19 4/0-01WP-7 4/0-01WP-19 250-01WP-19 300-01WP-19 350-01WP-19 500-01WP-37 750-01WP-61

14 12 10 9 8 6 4 3 2 1 1/0 2/0 6 4 2 1 1/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 250 300 350 500 750

SOLID SOLID SOLID SOLID SOLID SOLID SOLID SOLID SOLID SOLID SOLID SOLID 7/W 7/W 7/W 7/W 7/W 19/W 7/W 19/W 7/W 19/W 7/W 19/W 19/W 19/W 19/W 37/W 61/W

2/64 2/64 2/64 2/64 2/64 2/64 2/64 3/64 3/64 3/64 4/64 4/64 2/64 2/64 3/64 3/64 4/64 4/64 4/64 4/64 4/64 4/64 4/64 4/64 4/64 4/64 4/64 5/64 6/64

16.0 24.0 36.5 45.0 56.0 87.0 136.0 176.0 219.0 273.0 350.0 437.0 91.5 143.0 230.0 287.0 367.0 367.0 458.0 458.0 572.0 572.0 715.0 715.0 834.0 996.0 1157.0 1648.0 2481.0

16.5 24.6 37.1 45.7 56.8 87.8 137.0 177.4 222.0 277.0 355.0 443.0 92.0 144.0 233.0 291.0 372.0 372.0 464.0 464.0 578.0 578.0 722.0 722.0 842.0 1005.0 1166.0 1659.0 2494.0

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

415 20140902

TRANSMISSION.& DISTRIBUTION CABLES

Description Copper line wire available in vearious sizes, tempers and strandings with HMW-Polyethylene covering or crosslinked.

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Cathodic Protection Cable

Application Designed for use in Cathodic systems to protect against galvanic and electrolytic corrosion of underground or submerged metallic objects. Specifically applied to underground pipelines, dams and lock gates, fresh or salt water steel piles, tanks, condensers, and ship hulls. Specification • ASTM B-3 Bare Copper • ASTM B-8 Class B Stranding • ICEA S-70-547 • ASTM 1248

Item #

8-01CPC 6-01CPC 4-01CPC 2-01CPC 1-01CPC 1/0-01CPC 2/0-01CPC 3/0-01CPC 4/0-01CPC 250-01CPC 350-01CPC 500-01CPC

Size AWG or MCM

Stranding

Insulation Thickness (mil)

Nominal Weight /MFT (lb)

Nominal Diameter (in)

8 6 4 2 1 1/0 2/0 3/0 4/0 250 350 500

7/.0486 7/.0612 7/.0772 7/.0974 19/.0664 19/.0745 19/.0837 19/.0940 19/.1055 37/.0822 37/.0973 37/.1162

110 110 110 110 125 125 125 125 125 155 155 155

0.370 0.410 0.460 0.520 0.590 0.630 0.680 0.735 0.790 0.900 1.010 1.140

90 125 180 272 337 415 510 625 777 935 1269 1770

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

416 20140110

TRANSMISSION.& DISTRIBUTION CABLES

Description Soft drawn bare copper strand. High-molecular-weight, low density black polyethylene (HMW PE) covering.

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Transformer Riser Wire (Tap Wire)

Construction Soft drawn copper conductors, either solid or stranded, covered with HMW Polyethylene. Standards • ASTM B-3 • ASTM B-8 • ANSI C-8.35

Item #

TRW-8S TRW-6S TRW-6 TRW-4S TRW-4

Size

Stranding

Covering Thickness (mil)

Diameter Bare Conductor (mil)

Diameter Covered (mil)

Weight /MFT (lb)

8 6 6 4 4

SOLID SOLID .0612 7 STRANDS SOLID .0772 7 STRANDS

110 110 110 110 110

128.5 162.0 184.0 204.3 232.0

348.5 382.0 404.0 424.3 452.0

83 117 122 170 177

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

417 20140902

TRANSMISSION.& DISTRIBUTION CABLES

Application Used as non-insulated transformer risers intended to reduce faults due to atmospheric conditions, vibrations, and crossed leads.

TRANSMISSION & DISTRIBUTION CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

MULTIPLEX CABLES Table of Contents Aluminum Duplex Overhead Service Drop 600V................................................................206 Aluminum Triplex Overhead Service Drop 600V ................................................................207 Aluminum Quadruplex Overhead Service Drop 600V .......................................................208 Copper Duplex Service Drop Cable 600V ............................................................................227

Aluminum Single Secondary Type URD Cable ...................................................................209 Aluminum Duplex Secondary Type URD Cable ..................................................................210 Aluminum Triplex Secondary Type URD Cable ...................................................................211 Aluminum Quadruplex Secondary Type URD Cable ..........................................................212 Aluminum Mobile Home Feeder Type URD ........................................................................213 Packaging Information Duplex Overhead Service Drop.........................................................................................214 Triplex Overhead Service Drop .........................................................................................215 Quadruplex Overhead Service Drop.................................................................................216 Secondary Type URD Cable 600V: Single, Duplex, Triplex, Quadruplex ........................217

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

1000 20151123

MULTIPLEX CABLES

Copper Triplex Service Drop Cable 600V .............................................................................228 Copper Quadruplex Service Drop Cable 600V ....................................................................229

MULTIPLEX CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Aluminum Duplex Overhead Service Drop 600V Applications To supply 120V aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600V or lower at a conductor temperature of 75°C maximum. Construction Concentric strand or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.

Item #

Phase Conductor Size AWG

Phase Conductor Stranding

AAC Pekingese 6 Solid Collie 6 7 Dachshund 4 Solid Spaniel 4 7 Doberman 2 7 Malemute 1/0 19 ACSR Neutral Messenger Setter 6 Solid Shepherd 6 7 Eskimo 4 Solid Terrier 4 7 Chow 2 7 Bull 1/0 19 AAAC 6201 Alloy Neutral Messenger Chihuahua 6 Solid Vizsla 6 7 Harrier 4 Solid Whippet 4 7 Schnauzer 2 7 Heeler 1/0 19

Phase Conductor Insulation Thickness (mil)

Bare Neutral Messenger Size AWG

Bare Neutral Messenger Stranding

Bare Neutral Messenger Breaking (lb)

Weight /MFT XLP (lb)

Weight /MFT Poly (lb)

Ampacity XLP

Ampacity Poly

45 45 45 45 45 60

6 6 4 4 2 1/0

7 7 7 7 7 7

563 563 881 881 1350 1990

63.5 66.8 95.5 100.5 152.7 242.6

61.7 63.1 93.4 95.4 145.7 234.2

85 85 115 115 150 205

70 70 90 90 120 160

45 45 45 45 45 60

6 6 4 4 2 1/0

6/1 6/1 6/1 6/1 6/1 6/1

1190 1190 1860 1860 2850 4380

75.0 78.3 113.7 118.7 181.7 288.7

73.2 74.6 111.6 113.6 174.7 280.3

85 85 115 115 150 205

70 70 90 90 120 160

45 45 45 45 45 60

6 6 4 4 2 1/0

7 7 7 7 7 7

1110 1110 1760 1760 2800 4460

67.6 70.9 102.0 107.0 163.3 259.2

65.8 67.2 99.9 101.9 156.2 250.8

85 85 115 115 150 250

70 70 90 90 120 160

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

206 20160602

MULTIPLEX CABLES

Standards • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes. • B-231 Aluminum Conductors, Concentric-Lay-Stranded. • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR). • B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors. • B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR). • Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

MULTIPLEX CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Aluminum Triplex Overhead Service Drop 600V Applications To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600V or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene Insulation or 90°C maximum for cross-linked insulation.

Standards • B-230 Aluminum Wire 1350-H19 for Electrical Purposes • B-231 Aluminum Conductors, Concentric-Lay-Stranded • B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) • B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors • B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR). • Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76474

Item #

Phase Conductor Size AWG

AAC Neutral Messenger Haiotis 6 Patella 6 Fusus 4 Oyster 4 Clam 2 Murex 1/0 Purpura 1/0 Nassa 2/0 Melita 3/0 Portunus 4/0 Nannynose 336.4 Full Size ACSR Messenger Paludina 6 Voluta 6 Whelk 4 Periwinkle 4 Conch 2 Neritina 1/0 Cenia 1/0 Runcina 2/0 Triton 2/0 Cherrystone 3/0 Mursia 3/0 Razor 4/0 Zuzara 4/0 Limpet 336.4

Phase Conductor Stranding

Phase Conductor Insulation Thickness (mil)

Bare Neutral Messenger Size AWG

Bare Neutral Messenger Stranding

Bare Neutral Messenger Breaking (lb)

Weight /MFT XLP (lb)

Weight /MFT Poly (lb)

Ampacity XLP

Ampacity Poly

Solid 7 Solid 7 7 7 19 7 19 19 19

45 45 45 45 45 60 60 60 60 60 80

6 6 4 4 2 1/0 1/0 2/0 3/0 4/0 336.4

7 7 7 7 7 7 7 7 19 19 19

563 563 881 881 1350 1990 1990 2510 3310 4020 6146

102.5 109.1 151.9 161.8 243.2 395.1 386.1 485.8 585.2 723.9 1160.4

98.8 101.6 147.6 151.7 229.2 369.4 369.4 455.3 562.9 697.3 1118.0

85 85 115 115 150 205 205 235 275 315 420

70 70 90 90 120 160 160 185 215 245 325

Solid 7 Solid 7 7 7 19 7 19 7 19 7 19 19

45 45 45 45 45 60 60 60 60 60 60 60 60 80

6 6 4 4 2 1/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 336.4

6/1 6/1 6/1 6/1 6/1 6/1 6/1 6/1 6/1 6/1 6/1 6/1 6/1 18/1

1190 1190 1860 1860 2850 4380 4380 5310 5310 6620 6620 8350 8350 8680

114 120 169 176 267 530 426 530 526 656 650 814 805 1209

113 113 165 172 261 419 416 519 514 643 638 799 792 1167

85 85 115 115 150 205 205 235 235 250 250 315 315 420

70 70 90 90 120 160 160 185 185 200 200 245 245 325

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

207 20140921

MULTIPLEX CABLES

Construction Concentric strand or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene insulation, concentric strand AAC, ACSR or 6201 alloy neutral messenger.

Aluminum Triplex Overhead Service Drop 600V

MULTIPLEX CABLES

Item #

Phase Conductor Size AWG

Phase Conductor Stranding

ACSR Reduced Messenger Scallop 4 Solid Strombus 4 7 Cockle 2 7 Janthina 1/0 7 Ranella 1/0 19 Cavolinia 2/0 7 Clio 2/0 19 Sanddollar 3/0 7 Aega 3/0 19 Cuttlefish 4/0 7 Cerapus 4/0 19 Cowry 336.4 19 AAAC 6201 Alloy Neutral Messenger Minex 6 Solid Hippa 6 7 Prawn 4 Solid Barnacles 4 7 Shrimp 2 7 Gammarus 1/0 7 Leda 1/0 19 Dungenese 2/0 7 Cyclops 2/0 19 Flustra 3/0 19 Lepas 4/0 19 AAAC 6201 Alloy Reduced Neutral Messenger Artemia 4 Solid Crab 4 7 Solaster 2 7 Sandcrab 1/0 7 Echinus 1/0 19 Crayfish 2/0 7 Sipho 2/0 19 Fulgar 3/0 19 Arca 4/0 19

Phase Conductor Insulation Thickness (mil)

Bare Neutral Messenger Size AWG

Bare Neutral Messenger Stranding

Bare Neutral Messenger Breaking (lb)

Weight /MFT XLP (lb)

Weight /MFT Poly (lb)

Ampacity XLP

Ampacity Poly

45 45 45 60 60 60 60 60 60 60 60 80

6 6 4 2 2 1 1 1/0 1/0 2/0 2/0 4/0

6/1 6/1 6/1 6/1 6/1 6/1 6/1 6/1 6/1 6/1 6/1 6/1

1190 1190 1860 2850 2850 3550 3550 4380 4380 5310 5310 8350

148 158 233 376 372 462 458 570 565 706 699 1135

144 148 227 365 362 451 446 557 552 691 684 1093

115 115 150 205 205 235 235 275 275 315 315 420

90 90 120 160 160 185 185 215 215 245 245 325

45 45 45 45 45 60 60 60 60 60 60

6 6 4 4 2 1/0 1/0 2/0 2/0 3/0 4/0

7 7 7 7 7 7 7 7 7 7 7

1110 1110 1760 1760 2800 4460 4460 5390 5390 6790 8560

106.6 113.2 158.4 168.3 253.7 411.7 402.7 506.8 495.3 611.4 757.1

102.9 105.7 154.1 158.2 239.7 386.0 386.0 476.3 476.3 589.1 730.5

85 85 115 115 150 205 205 235 235 275 315

70 70 90 90 120 160 160 185 185 215 245

45 45 45 60 60 60 60 60 60

6 6 4 2 2 1 1 1/0 2/0

7 7 7 7 7 7 7 7 7

1110 1110 1760 2800 2800 3530 3530 4460 5390

141.4 151.3 226.6 368.8 358.8 452.6 441.0 543.4 671.2

137.1 141.2 212.6 343.1 343.1 422.5 422.5 521.1 644.6

115 115 150 205 205 235 235 275 315

90 90 120 160 160 185 185 215 245

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 207 20140921

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Aluminum Quadruplex Overhead Service Drop 600V Applications Used to supply 3 phase power, usually from a pole- mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600V or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLP) insulated conductors.

Standards • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes. • B-231 Aluminum conductors, Concentric-Lay-Stranded. • B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR). • B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors. • B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR). • Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76474. Note Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTMB399 for 6201. Conductor temperature of 90°C for XLR 75°C for Poly; ambient temperatures of 40°C; emissivity 0.9; 2ft./sec ind in sun. To determine current ampacity by conductor size, please consult The National Electric Code, latest edition.

Item #

Phase Conductor Size AWG

AAC Neutral Messenger Clydesdale 4 Pinto 4 Mustang 2 Criollo 1/0 Percheron 2/0 Hanoverian 3/0 Oldenburg 4/0 Lippizaner 336.4 ACSR Neutral Messenger Morochuca 6 Chola 6 Morgan 4 Hackney 4 Palomino 2 Costena 1/0 Grullo 2/0 Suffolk 3/0 Appaloosa 4/0 Bronco 336.4 Gelding 336.4

Phase Conductor Stranding

Phase Conductor Insulation Thickness (mil)

Bare Neutral Messenger Size AWG

Bare Neutral Messenger Stranding

Bare Neutral Messenger Breaking (lb)

Weight /MFT XLP (lb)

Weight /MFT Poly (lb)

Ampacity XLP

Ampacity Poly

Solid 7 7 19 19 19 19 19

45 45 45 60 60 60 60 80

4 4 2 1/0 2/0 3/0 4/0 336.4

7 7 7 7 7 19 19 19

881 881 1350 1990 2510 3310 4020 6146

208 223 333 529 649 799 986 1546

201.8 207.9 312.6 504.5 620.5 765.6 946.7 1519.2

100 100 135 180 205 235 275 370

80 80 105 140 160 185 210 280

Solid 7 Solid 7 7 19 19 19 19 19 19

45 45 45 45 45 60 60 60 60 80 80

6 6 4 4 2 1/0 2/0 3/0 4/0 336.4 4/0

6/1 6/1 6/1 6/1 6/1 6/1 6/1 6/1 6/1 18/1 6/1

1190 1190 1860 1860 2850 4380 5310 6620 8350 8580 8350

152 162 226 241 362 575 707 872 1079 1613 1548

147.4 151.7 220 226.1 342.6 550.6 678.7 838.9 1039.2 1568.2 1494.3

75 75 100 100 135 180 205 235 275 370 370

60 60 80 80 105 140 160 185 210 280 280

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

208 20140921

MULTIPLEX CABLES

Construction Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP cross-linked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.

Aluminum Quadruplex Overhead Service Drop 600V

MULTIPLEX CABLES

Item #

Phase Conductor Size AWG

Phase Conductor Stranding

AAAC 6201 Alloy Neutral Messenger Bay 6 Solid French Coach 6 7/w German Coach 4 Solid Arabian 4 7/w Belgian 2 7/w Shetland 1/0 19/w Thoroughbred 2/0 19/w Trotter 3/0 19/w Walking 4/0 19/w

Phase Conductor Insulation Thickness (mil)

Bare Neutral Messenger Size AWG

Bare Neutral Messenger Stranding

Bare Neutral Messenger Breaking (lb)

Weight /MFT XLP (lb)

Weight /MFT Poly (lb)

Ampacity XLP

Ampacity Poly

45 45 45 45 45 60 60 60 60

6 6 4 4 2 1/0 2/0 3/0 4/0

7 7 7 7 7 7 7 7 7

1110 1110 1760 1760 2800 4460 5390 6790 8560

145 155 214 229 344 546 670 825 1019

140.0 144.3 208.3 214.4 323.1 521.1 641.5 791.8 979.7

75 75 100 100 135 180 205 235 275

60 60 80 80 105 140 160 185 210

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 208 20140921

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Copper Duplex Service Drop Cable 600V Application Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. Also suitable for installations for street lighting, security lights, and temporary service for construction. To be used at voltages of 600 volts phase-tophase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors and 90°C for cross-linked polyethylene (XLP) insulated conductors. MULTIPLEX CABLES

Specifications Meets or exceeds the following ASTM specifications: • B-1 Hard-Drawn Copper Wire • B-3 Soft or Annealed Copper Wire • B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474 for polyethylene and crosslinked polyethylene insulated conductors. Construction Conductors are concentrically stranded compressed soft copper insulated with either crosslinked polyethylene, or conventional polyethylene. Neutral messengers are either solid or concentrically stranded bare hard-drawn copper. Notes: • Code words for XLP insulated products are formed by adding "XLP" to the conventional polyethylene code words above (e.g. Theta/XLP). • Ampacity figures for black insulation only. Based on conductor temperature of 75°C for polyethylene insulated conductors,90°C for XLP insulated conductors, ambient temperature of 40°C; 2 ft./sec. wind in sun.

Item #

Theta Omega Iota Kappa Lambda Omicron Sigma

Phase Conductor Size AWG

Phase Conductor Stranding

Phase Conductor Cover Thickness (mil)

8 8 8 8 6 6 6

7 1 7 7 7 7 7

45 45 45 45 45 45 45

Neutral Neutral Neutral Messenger Messenger Messenger Size Stranding Rated AWG Strength (lb) 10 8 8 8 8 6 6

1 1 1 7 1 1 7

529 826 826 777 826 1280 1228

Nominal Lay Length (in)

Weight /MFT XLP (lb)

Weight /MFT Poly (lb)

Allowable Ampacities XLP

Allowable Ampacities Poly

10.36 10.36 10.36 10.36 10.36 10.36 10.36

96 112 115 116 149 179 180

97 113 116 117 149 179 181

85 85 85 85 110 110 110

70 70 70 70 90 90 90

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

227 20140110

MULTIPLEX CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Copper Triplex Service Drop Cable 600V Application Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. Also suitable for installations for street lighting, security lights, and temporary service for construction. To be used at voltages of 600 volts phase-tophase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors and 90°C for cross-linked polyethylene (XLP) insulated conductors. MULTIPLEX CABLES

Specifications Meets or exceeds the following ASTM specifications: • B-1 Hard-Drawn Copper Wire • B-3 Soft or Annealed Copper Wire • B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474 for polyethylene and crosslinked polyethylene insulated conductors. Construction Conductors are concentrically stranded compressed soft copper insulated with either crosslinked polyethylene, or conventional polyethylene. Neutral messengers are either solid or concentrically stranded bare hard-drawn copper. Notes: • Code words for XLP insulated products are formed by adding "XLP" to the conventional polyethylene code words above (e.g. Pica/XLP). • Ampacity figures for black insulation only. Based on conductor temperature of 75°C for polyethyl ene insulated conductors, 90°C for XLP insulated conductors, ambient temperature of 40°C; 2 ft./sec. wind in sun.

Item #

Pica Columbian Bodoni Garamond Tudor Futura Gothic Nonpareil Ionic Caslon Minion Primer Century Corinthian Doric

Phase Conductor Size AWG

Phase Conductor Stranding

Phase Conductor Cover Thickness (mil)

8 8 8 8 6 6 6 4 4 4 2 2 2 1/0 2/0

7 1 7 7 7 7 7 7 7 7 7 7 7 19 19

45 45 45 45 45 45 45 45 45 45 45 45 45 60 60

Neutral Neutral Neutral Messenger Messenger Messenger Size Stranding Rated AWG Strength (lb) 10 8 8 8 8 6 6 6 4 4 4 4 2 1/0 2/0

1 1 1 7 1 1 7 1 1 7 1 7 7 7 7

529 826 826 777 826 1280 1228 1280 1970 1938 1970 1938 3050 4752 5926

Nominal Lay Length (in)

Weight /MFT XLP (lb)

Weight /MFT Poly (lb)

Allowable Ampacities XLP

Allowable Ampacities Poly

10.36 10.36 10.36 10.36 14.88 14.88 14.88 14.88 14.88 14.88 20.58 20.58 20.58 20.58 25.42

160 174 179 180 246 276 278 381 429 432 594 596 674 1073 1342

149 164 167 169 232 262 263 363 411 413 571 574 651 1036 1301

85 85 85 85 110 110 110 145 145 145 195 195 195 265 300

70 70 70 70 90 90 90 115 115 115 155 155 155 205 235

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

228 20140110

MULTIPLEX CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Copper Quadruplex Service Drop Cable 600V Application Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. Also suitable for installations for street lighting, security lights, and temporary service for construction. To be used at voltages of 600 volts phase-tophase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors and 90°C for cross-linked polyethylene (XLP) insulated conductors. MULTIPLEX CABLES

Specifications Meets or exceeds the following ASTM specifications: • B-1 Hard-Drawn Copper Wire • B-3 Soft or Annealed Copper Wire • B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474 for polyethylene and crosslinked polyethylene insulated conductors. Construction Conductors are concentrically stranded compressed soft copper insulated with either crosslinked polyethylene, or conventional polyethylene. Neutral messengers are either solid or concentrically stranded bare hard-drawn copper. Notes: • Code words for XLP insulated products are formed by adding "XLP" to the conventional polyethylene code words above (e.g. Atlanta/XLP). • Ampacity figures for black insulation only. Based on conductor temperature of 75°C for polyethylene insulated conductors,90°C for XLP insulated conductors, ambient temperature of 40°C; 2 ft./sec. wind in sun.

Item #

Atlanta Tallahassee Richmond BatonRouge Jackson Seattle Nashville Lincoln Raleigh Denver

Phase Conductor Size AWG

Phase Conductor Stranding

Phase Conductor Cover Thickness (mil)

6 6 4 4 2 2 1/0 2/0 3/0 4/0

7 7 7 7 7 7 19 19 19 19

45 45 45 45 45 45 60 60 60 60

Neutral Neutral Neutral Messenger Messenger Messenger Size Stranding Rated AWG Strength (lb) 6 6 4 4 2 2 1/0 2/0 3/0 4/0

1 7 1 7 1 7 7 7 7 7

1280 1228 1970 1938 3003 3050 4752 5926 7366 9154

Nominal Lay Length (in)

Weight /MFT XLP (lb)

Weight /MFT Poly (lb)

Allowable Ampacities XLP

Allowable Ampacities Poly

20.58 20.58 20.58 20.58 25.42 25.42 25.42 29.97 35.18 35.18

359 361 560 563 879 883 1405 1761 2209 2773

344 346 542 545 856 860 1368 1720 2163 2721

95 95 125 125 170 170 230 265 305 350

75 75 100 100 135 135 180 205 235 270

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

229 20140110

MULTIPLEX CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Aluminum Single Secondary Type URD Cable 600V Applications Directly buried or installed in ducts for 600V secondary distribution. Construction Concentric stranded or compressed 1350-H19 aluminum conductor, cross-linked polyethylene insulation.

Options • Cable in Duct (CIC) • Abrasion Resistant Ampacity 90°C conductor temperature, 20°C ambient, RHO factor 90, 100% load factor for three conductor triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.

Item #

Princeton Mercer Clemson Kenyon Harvard Yale Tufts Beloit Hofstra Gonzaga Rutgers Emory Duke Furman Sewanee Fordham

Size AWG or MCM

Stranding

Insulation Thickness (mil)

Outside Diameter (in)

Weight /MFT (lb)

Ampacity Direct Burial

Ampacity In Duct

6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 500 600 700 750 1000

7 7 7 19 19 19 19 19 37 37 37 37 61 61 61 61

60 60 60 80 80 80 80 80 95 95 95 95 110 110 110 110

.298 .345 .403 .522 .482 .566 .616 .672 .748 .801 .851 .979 1.086 1.155 1.188 1.337

45 64 93 148 122 179 217 265 317 371 423 579 701 804 855 1109

90 120 155 200 175 225 250 290 320 355 385 465 510 550 580 670

65 85 115 150 130 170 195 225 250 280 305 370 410 440 470 545

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

209 201400921

MULTIPLEX CABLES

Standards Secondary URD single conductor 600V cable meets or exceeds the following ASTM specifications. • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes. • B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded. • B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation". • B-901 "Compressed round stranded Aluminum Conductors using single input wire construction". • Secondary URD single conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692. • “USE-2” per UL 854 available upon request.

MULTIPLEX CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Aluminum Duplex Secondary Type URD Cable 600 V Applications Directly buried or installed in ducts for 600V secondary distribution. Construction Concentric stranded or compressed 1350-H19 aluminum conductor, cross-linked polyethylene insulation.

Options • Cable in Duct (CIC) • Abrasion Resistant Ampacity 90°C conductor temperature, 20°C ambient, RHO factor 90, 100% load factor for three conductor triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.

Item #

Bard Claflin Delgado Everett

Phase Conductor Size AWG

Phase Conductor Stranding

Phase Conductor Insulation Thickness (mil)

Neutral Size AWG

Neutral Stranding

Neutral Insulation Thickness (mil)

Single Phase Conductor (in)

Outside Diameter (in)

Weight /MFT Poly (lb)

Ampacity Direct Burial

Ampacity in Duct

8 6 4 2

7 7 7 7

60 60 60 60

8 6 4 2

7 7 7 7

60 60 60 60

.262 .299 .345 .403

.524 .596 .690 .806

76 91 129 189

70 95 125 187

70 70 90 100

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

210 20140921

MULTIPLEX CABLES

Standards Secondary URD single conductor 600V cable meets or exceeds the following ASTM specifications. • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes. • B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded. • B-786 "19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation". • B-901 "Compressed round stranded Aluminum Conductors using single input wire construction". • Secondary URD single conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692. • “USE-2” per UL 854 available upon request.

MULTIPLEX CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Aluminum Triplex Secondary Type URD Cable 600 V Applications Directly buried or installed in ducts for 600V secondary distribution. Construction Concentric stranded or compressed 1350-H19 aluminum conductor, cross-linked polyethylene insulation.

Options • Cable in Duct (CIC) • Abrasion Resistant Ampacity 90°C conductor temperature, 20°C ambient, RHO factor 90, 100% load factor for three conductor triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.

Item #

Erskine Vassar Stephens Ramapo Brenau Bergen Converse Hunter Hollins Rockland Sweetbriar Monmouth Pratt Wesleyan Holyoke Rider Fairfield

Phase Conductor Size AWG

Phase Conductor Stranding

Phase Conductor Insulation Thickness (mil)

Neutral Size AWG

Neutral Stranding

Neutral Insulation Thickness (mil)

Single Phase Conductor (in)

Outside Diameter (in)

Weight /MFT Poly (lb)

Ampacity Direct Burial

Ampacity in Duct

6 4 2 2 1/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 250 350 500 500 750

7 7 7 7 19 19 19 19 19 19 19 19 37 37 37 37 61

60 60 60 60 80 80 80 80 80 80 80 80 95 95 95 95 110

6 4 4 2 2 1/0 1 2/0 1/0 3/0 2/0 4/0 3/0 4/0 300 350 500

7 7 7 7 7 19 19 19 19 19 19 19 19 19 37 37 37

60 60 60 60 60 80 80 80 80 80 80 80 80 80 95 95 95

.299 .345 .403 .403 .522 .522 .566 .566 .616 .616 .672 .672 .748 .851 .979 .979 1.188

.646 .754 .842 .874 1.064 1.133 1.174 1.228 1.276 1.336 1.389 1.457 1.538 1.736 2.008 2.035 2.0860

143 203 264 294 408 465 502 560 606 678 739 828 893 1166 1607 1663 2304

95 125 165 165 215 215 245 245 280 280 315 315 345 415 495 495 615

70 90 120 120 160 160 160 180 205 205 240 240 265 320 395 395 525

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

211 201400921

MULTIPLEX CABLES

Standards Secondary URD single conductor 600V cable meets or exceeds the following ASTM specifications. • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes. • B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded. • B-786 “19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation.” • B-901 “Compressed round stranded Aluminum Conductors using single input wire construction.” • Secondary URD single conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692. • “USE-2” per UL 854 available upon request.

MULTIPLEX CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Aluminum Quadruplex Secondary Type URD Cable 600 V Applications Directly buried or installed in ducts for 600V secondary distribution. Construction Concentric stranded or compressed 1350-H19 aluminum conductor, cross-linked polyethylene insulation.

Options • Cable in Duct (CIC) • Abrasion Resistant Ampacity 90°C conductor temperature, 20°C ambient, RHO factor 90, 100% load factor for three conductor triplexed, 3 phase operation. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.

Item #

Tulsa Dyke Wittenberg Notre Dame Purdue Syracuse Lafayette Swarthmore Davidson Wake Forest Earlham Slippery Rock Wofford Windham

Phase Conductor Size AWG

Phase Conductor Stranding

Phase Conductor Insulation Thickness (mil)

Neutral Size AWG

Neutral Stranding

Neutral Insulation Thickness (mil)

Single Phase Conductor (in)

Outside Diameter (in)

Weight /MFT Poly (lb)

Ampacity Direct Burial

Ampacity in Duct

4 2 2 1/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 350 500 750

7 7 7 19 19 19 19 19 19 19 19 37 37 61

60 60 60 80 80 80 80 80 80 80 80 95 95 110

4 4 2 2 1/0 1 2/0 1/0 3/0 2/0 4/0 4/0 350 500

7/w 7/w 7/w 7/w 19/w 19/w 19/w 19/w 19/w 19/w 19/w 19/w 37/w 37/w

60 60 60 60 80 80 80 80 80 80 80 80 95 95

.345 .403 .403 .522 .522 .566 .566 .616 .616 .672 .672 .851 .851 .979

.833 .938 .973 1.188 1.260 1.316 1.367 1.430 1.487 1.560 1.623 1.945 2.348 2.850

258 346 375 541 596 664 720 805 874 979 1066 1544 2174 2542

119 153 153 198 198 225 225 250 250 290 290 385 467 615

85 115 115 150 150 170 170 195 195 225 225 305 420 492

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

212 20160603

MULTIPLEX CABLES

Standards Secondary URD single conductor 600V cable meets or exceeds the following ASTM specifications. • B-230 Aluminum Wire, 1350-H19 for Electrical Purposes. • B-231 Aluminum 1350 conductors, Concentric-Lay-Stranded. • B-786 “19 Wire combination unilay-stranded Aluminum Conductors for subsequent insulation.” • B-901 “Compressed round stranded Aluminum Conductors using single input wire construction.” • Secondary URD single conductor 600V cable meets or exceeds all applicable requirements of ICEA S-105-692. • “USE-2” per UL 854 available upon request.

MULTIPLEX CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Aluminum Mobile Home Feeder Type URD 600 V Application Mobile Home Feeder Cable is mainly used for supplying the energy required within the mobile home. The cable is designed for use at 600V or less and conductor temperatures not exceeding 90°C.

Marking • Manufacturer's ID plus E FILE NUMBER (SIZE AWG) AA-8000 AL TYPE USE-2 OR RHH OR RHW-2 SUN-RES 600V XLPE (UL) plus YEAR OF MANUFACTURE. • Sequential footage markings. Installation Suitable for direct burial or underground installations and in raceways. Standards Mobile Home Feeder cable meets or exceeds the following specifications: • ASTM B800 and B801 or B836 as applicable. • UL 44 • UL 854 • NEC requirements. To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.

Item #

2-2-2-4 2-5-4-6 2/0-2/0-2/0-1 2/0-2/0-4-1 4/0-4/0-4/0-2/0 4/0-4/0-2/0-4

Phase Conductor Size AWG

Phase Conductor Const.

Phase Conductor Diameter (in)

Neutral Size AWG

Neutral Conductor Const.

Neutral Conductor Diameter (in)

Grounding Conductor Size AWG

Grounding Conductor Const.

Grounding Conductor Diameter (in)

Diameter Complete Cable (in)

Allowable Ampacity

2 2 2/0 2/0 4/0 4/0

7 7 19 19 19 19

0.403 0.403 0.566 0.566 0.672 0.672

2 4 2/0 1 4/0 2/0

7 7 19 19 19 19

0.403 0.345 0.566 0.482 0.672 0.566

4 6 1 4 2/0 4

7 7 19 7 19 7

0.345 0.298 0.482 0.345 0.566 0.345

0.942 0.938 1.321 1.210 1.567 1.480

100 100 150 150 200 200

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

213 20140924

MULTIPLEX CABLES

Construction Quadruplexed type USE-2 or RHH or RHW-2 compact stranded AA-8000 Series aluminum alloy conductors. Insulation is sunlight-resistant Cross-linked Polyethylene (XLPE). Neutral is identified by triple extruded white stripes and Grounding is identified by total green surface coating.

MULTIPLEX CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Packaging Information: Duplex Service Drop Aluminum Conductor Code Word

Aluminum Conductors Standard Packages Phase Neutral Length Weight Size & Size & (ft) Poly XLP Stranding Stranding (lb) (lb) 6-7

Spaniel

4-7

500 2,800 500 2,000

32 179 48 192

33 185 50 198

Coil NRC 30.18 Coil NRC 30.18

1,000 3,300 500 2,000

75 248 58 230

77 254 59 234

Coil NRC 38.18 Coil NRC 30.18

Aluminum Alloy 6201-T81 Messenger Vizsla 6-7 30580-7 500 2,800 Whippet 4-7 48690-7 500 2,000

34 190 52 206

35 196 53 210

Coil NRC 30.18 Coil NRC 30.18

4-7

ACSR Messenger Shepherd 6-7

6-6/1

Terrier

4-6/1

4-7

MULTIPLEX CABLES

AAC Messenger Collie 6-7

Reel Size

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

214 20140110

MULTIPLEX CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Packaging Information: Triplex Service Drop Aluminum Conductor Code Word

Aluminum Conductors Standard Packages Phase Neutral Length Weight Size & Size & (ft) Poly XLP Stranding Stranding (lb) (lb) 6-7

Oyster

4-7

4-7

Clam

2-7

2-7

Murex

1/0-7

1/0-7

Purpura

1/0-19

1/0-7

Nassa Traphon Quahog Melita Coquina Portunus

210-7 2/0-19 3/0-7 3/0-19 4/0-7 4/0-19

2/0-7 2/0-7 3/0-7 3/0-19 4/0-7 4/0-19

1,000 2,200 500 1,500 500 1,800 500 1,200 500 1,200 1,500 1,500 1,300 1,300 1,000 1,000

104 229 77 230 116 418 187 448 185 444 692 684 741 735 707 699

107 235 79 237 119 428 192 460 190 456 708 701 758 750 722 713

Coil NRC 30.18 Coil NRC 38.18 Coil NRC 36.24 Coil NRC 36.24 Coil NRC 36.24 NRC 42.26 NRC 42.26 NRC 42.26 NRC 42.26 NRC 42.26 NRC 42.26

1,000 2,200 4-6/1 500 1,500 2-6/1 500 1,800 1/0-6/1 500 1,200 1/0-6/1 500 1,200 2/0-6/1 1,500 2/0-6/1 1,500 3/0-6/1 1,300 3/0-6/1 1,300 4/0-6/1 1,000 4/0-6/1 1,000 336.4-18/1 1,000

115 253 86 238 131 470 210 503 208 499 779 771 836 829 799 792 1150

118 260 88 264 134 481 215 516 213 511 795 789 853 845 814 806 1180

Coil NRC 30.18 Coil NRC 30.18 Coil NRC 36.24 Coil NRC 36.24 Coil NRC 36.24 NRC 42.26 NRC 42.26 NRC 42.26 NRC 42.26 NRC 42.26 NRC 42.26 NRC 42.26

ACSR Full Size Messenger Voluta 6-7 6-6/1 Periwinkle

4-7

Conch

2-7

Neritina

1/0-7

Cenia

1/0-19

Runcina Triton Cherrystone Mursia Razor Zuzara Limpet

210-7 2/0-19 3/0-7 3/0-19 4/0-7 4/0-19 336.4-19

Code Word

Aluminum Conductors Standard Packages Phase Neutral Length Weight Size & Size & (ft) Poly XLP Stranding Stranding (lb) (lb)

AAAC-6201 Alloy Messenger Hippa 6-7 30580-7

54 214 77 260 80 240 121 436 195 468 193 463 723 716 775 768 740 733

56 222 79 269 83 248 125 448 200 480 198 475 740 732 792 784 755 746

Coil NRC 30.18 Coil NRC 30.18 Coil NRC 30.18 Coil NRC 36.24 Coil NRC 36.24 Coil NRC 36.24 NRC 42.26 NRC 42.26 NRC 42.26 NRC 42.26 NRC 42.26 NRC 42.26

Aluminum Alloy 6201-T81 Reduced Size Messenger Crab 4-7 30580-7 500 72 1,500 215 Solaster 2-7 48690-7 500 108 1,800 367 Sandcrab 1/0-7 77470-7 500 174 1,200 416 Echinus 1/0-19 77470-7 500 172 1,200 412 Crayfish 2/0-7 97633-7 1,500 641 Sipho 2/0-19 97633-7 1,500 635 Slub 3/0-7 123300-7 1,300 686 Fulgar 310-19 123300-7 1,300 680 Squid 4/0-7 155400-7 1,000 654 Arca 4/0-19 155400-7 1,000 647

74 222 111 400 179 428 177 424 659 651 703 696 669 661

Coil NRC 30.18 Coil NRC 36.24 Coil NRC 36.24 Coil NRC 36.24 NRC 42.26 NRC 42.26 NRC 42.26 NRC 42.26 NRC 42.26 NRC 42.26

Prawn

4-1

48690-7

Barnacle

4-7

48690-7

Shrimp

2-7

77470-7

Gammarus

1/0-7

123300-7

Leda

1/0-19 123300-7

Dungeness Cyclops Stonecrab Flustra Kingcrab Lepas

2/0-7 155400-7 2/0-19 155400-7 3/0-7 195700-7 3/0-19 195700-7 4/0-7 246900-7 4/0-19 2469W-7

500 2,000 Soo 1,700 500 1,500 500 1,800 500 1,200 500 1,200 1,500 1,500 1,300 1,300 1,000 1,000

Reel Size

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

215 20140110

MULTIPLEX CABLES

AAC Neutral Messenger Patella 6-7

Reel Size

Packaging Information: Triplex Service Drop Aluminum Conductor

Aluminum Conductors Standard Packages Phase Neutral Length Weight Size & Size & (ft) Poly XLP Stranding Stranding (lb) (lb) ACSR Reduced Size Messenger

MULTIPLEX CABLES

Code Word

Stombus

4-7

6-6/1

Cockle

2-7

4-6/1

lanthina

1/0-7

2-6/1

Ranelia

1/0-19

2-6/1

Cavolinia Clio Sanddollar Aega Cuttlefish Cerapus

2/0-7 2/0-19 3/0-7 3/0-19 4/0-7 4/0-19

1-6/1 1-6/1 1/0-6/1 1/0-6/1 2/0-6/1 2/0-6/1

500 1,500 500 1,800 500 1,200 500 1,200 1,500 1,500 1,300 1,300 1,000 1,000

76 228 114 409 183 438 181 434 677 669 724 718 691 684

78 233 117 419 188 451 186 446 693 687 741 735 706 699

Reel Size

Coil NRC 30.18 Coil NRC 36.24 Coil NRC 36.24 Coil NRC 36-24 NRC 42.26 NRC 42.26 NRC 42.26 NRC 42.26 NRC 42.26 NRC 42.26

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 215 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Packaging Information: Quadraplex Service Drop Aluminum Conductor Code Word

Aluminum Conductors Standard Packages Phase Neutral Length Weight Size & Size & (ft) Poly XLP Stranding Stranding (lb) (lb) AAC Neutral Messenger 4-7

4-7

Mustang

2-7

2-7

Libyan

1/0-7

1/0-7

Criollo

1/0-19

1/0-7

Orloff

2/0-7

210-7

Percheron

2/0-19

2/0-7

Mongolian

310-7

3/0-7

Hanoverian

3/0-19

3/0-19

Singlefoot

4/0-7

4/0-7

Oldenberg

4/0-19

4/0-19

ACSR Messenger Chola 6-7 Hackney

4-7

Palornino

2-7

Standardbred 1/0-7 Costena

1/0-19

Chicoteagues 2/0-7 Grullo

2/0-19

Mare

3/0-7

Suffolk

3/0-19

Stallion

4/0-7

Appaloosa

4/0-19

Bronco

336.4-19

6-6/1

500 1,500 500 1,800 550 1,100 550 1,100 750 1,500 750 1,500 650 1,300 650 1,300 500 1,000 500 1,000

500 2,100 4-6/1 500 1,500 2-6/1 500 1,800 1/0-6/1 550 1,100 110-6/1 550 1,200 2/0-6/1 750 1,500 210-6/1 750 1,500 310-6/1 650 1,300 3/0-6/1 650 1,300 4/0-6/-l 500 1,000 4/0-16/1 500 1,000 336.4-18/1 1,000

106 317 159 571 281 561 278 556 472 944 467 933 504 1009 499 998 481 961 475 950

77 322 115 344 173 623 306 612 303 606 515 1031 510 1,020 522 1,104 547 1,093 527 1,053 521 1,042 1510

109 327 163 587 288 576 286 572 485 969 479 959 517 1034 512 1,023 492 983 486 971

80 334 118 354 178 639 315 629 311 623 528 1056 523 1,046 565 1,130 559 1,118 538 1,075 532 1,063 1587

Coil NRC 36.24 Coil NRC 42.26 NRC 36.24 NRC 42.26 NRC 36.24 NRC 42.26 NRC 36.24 NRC 50.32 NRC 36.24 NRC 50.32 NRC 36.24 NRC 50.32 NRC 36.24 NRC 50.32 NRC 40.24 NRC 50.32 NRC 40.24 NRC 50.32

Code Word

Aluminum Conductors Standard Packages Phase Neutral Length Weight Size & Size & (ft) Poly XLP Stranding Stranding (lb) (lb) AAAC-6201 Alloy Neutral Messenger French Coach 6-7

30580-7

Arabian

4-7

48690-7

Belgian

2-7

77470-7

Plow

110-7

123300-7

Shetland

1/0-19 123300-7

Dapple-Grey 2/0-7

155400-7

Thoroughbred 2/0-19 155400-7 Dobbin

3/0-7

195700-7

Trotter

3/0-19

195700-7

Pony

4/0-7

246900-7

Walking

4/0-19 246900-7

500 2,000 500 1,500 500 1,800 550 1,100 550 1,100 750 1,500 750 1,500 650 1,300 650 1,300 500 1,000 500 1,000

73 290 109 326 164 589 290 580 287 574 488 975 482 965 521 1,043 516 1,032 497 994 492 983

76 302 112 336 169 607 298 596 295 591 500 1001 495 990 534 1,069 528 1,057 508 1,016 502 1004

Reel Size

Coil NRC 36.24 Coil NRC 36.24 Coil NRC 42.26 NRC 36.24 NRC 42.26 NRC 36.24 NRC 42.26 NRC 36.24 NRC 50.32 NRC 36.24 NRC 50.32 NRC 36.24 NRC 50.32 NRC 36.24 NRC 50.32 NRC 40.24 NRC 50.32 NRC 40.24 NRC 50.32

Coil NRC 36.24 Coil NRC 36.24 Coil NRC 42.26 NRC 36.24 NRC 42.26 NRC 36.24 NRC 42.26 NRC 36.24 NRC 50.32 NRC 36.24 NRC 50.32 NRC 36.24, NRC 50.32 NRC 36.24 NRC 50.32 NRC 40.24 NRC 50.32 NRC 40.24 NRC 50.32 NRC 50.32

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

216 20140110

MULTIPLEX CABLES

Pinto

Reel Size

MULTIPLEX CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Packaging Information: Secondary Type URD Cable Code Word

Aluminum Conductor Standard Packages Size Stranding Length Weight Reel AWG or (ft) (lb) Size Cir. Mils

1,000 7,000 1,000 5,000 1,000 5,000 1,000 5,500 1,000 4,800 1,000 1,000 4,100 1,000 1,000 1,000 1,000 1,000

98 686 131 655 157 785 189 1,040 229 1,100 278 278 1,140 336 448 611 902 1,166

NRC 24.12 NRC 36.24 NRC 24.12 NRC 36.24 NRC 24.12 NRC 40.24 NRC 24.18 NRC 42.26 NRC 24.18 NRC 42.26 NRC 24.18 NRC 30.15 NRC 42.26 NRC 30.18 NRC 32.24 NRC 36.24 NRC 40.24 NRC 42.26

Quadruplex Conductor Type URD Cable Tulsa 4-7 4-7 1,000 1,500 Dyke 2-7 4-7 1,000 1,400 1,500 Wittenberg 2-7 2-7 1,000 1,400 1,500 Notre Dame 1/0-19 2-7 1,000 1,400 1,500 Purdue 1/0-19 1/0-19 1,000 1,400 1,500 Syracuse 2/0-19 1-19 1,000 1,400 1,500 Lafayette 2/0-19 2/0-19 1,000 Wake Forest 4/0-19 2/0-19 1,000 1,400 1,500 Farlham 4/0-19 4/0-19 1,000 1,500 Slippery Rock 350-37 4/0-19 1,000 1,400

258 387 346 484 519 375 525 563 541 757 812 596 834 894 664 930 996 720 979 1371 1469 1066 1599 1544 2162

NRC 32.24 NRC 34.26 NRC 32.24 NRC 40.24 NRC 40.24 NRC 32.24 NRC 40.24 NRC 40.24 NRC 40.24 NRC 48.28 NRC 48.28 NRC 42.26 NRC 48.28 NRC 48.28 NRC 42.26 NRC 50.32 NRC 50.32 NRC 42.28 NRC 50.32 NRC 54.32 NRC 54.32 NRC 50.32 NRC 54.32 NRC 60.28 NRC 66.28

Kenyon

1

19

Harvard

1/0

19

Yale

210

19

Tufts

3/0

19

Beloit

4/0

19

250000 350000 500000 750000 1000000

37 37 37 61 61

Hoistra Rutgers Emory Sewanee Fordham

Aluminum Conductor Standard Packages Size Stranding Length Weight Reel AWG or (ft) (lb) Size Cir. Mils

Triplex Conductor Type URD Cable Stephens 2-7 4-7 Brenau 1/0-19 2-7 Converse 2/0-19 1-19 Hollins 3/0-19 1/0-19 Sweetbriar 4/0-19 2/0-19 Pratt 250000-37 3/0-19 Wesleyan 350000-37 4/0-19 Rider 500000-37 350000-37

1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000

262 409 504 609 740 896 1,168 1,606

NRC 32.24 NRC 36.24 NRC 40.24 NRC 42.26 NRC 42.26 NRC 50.32 NRC 50.32 NRC 58.32

Triplex Conductor Type URD Cable Ramapo 2 2-7 Bergen 1/0 1/0-19 Hunter 210 2/0-19 Rockland 3/0 3/0-19 Monmouth 4/0 4/0-19

1,000 1,000 1,000 1,000 1,000

291 465 561 680 827

NRC 32.24 NRC 40.24 NRC 40.24 NRC 42.26 NRC 45.28

Also available master reel lengths up to 20,000 ft. We custom cut to any length you need.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

217 20140902

MULTIPLEX CABLES

Single Conductor Type URD Cable Clemson 2 7

Code Word

MULTIPLEX CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

LOW VOLTAGE CABLES Table of Contents TowerGuard CCA® 2kV RHH or RHW-2 ................................................................................201 Aluminum HYLUG™ Terminal and HYLINK™ Splice Connectors .....................................242 Aluminum XLP UL XHHW-2 90° 600V..................................................................................205 Aluminum XLP UL RHH/RHW-2 or USE-2 90°C 600V .........................................................204 TowerGuard® Aluminum XLP UL RHH/RHW-2 or USE-2 90°C 2kV....................................202 Towerguard Plus® Class 33 Aluminum XLPE 105°C 2kV ....................................................240 SunGuardTM Aluminum XLPE UL Type PV Photovoltaic Wire 600V ..................................230 SunGuardTM Aluminum XLPE UL Type PV Photovoltaic Wire 2kV PHYSICAL & ELECTRICAL PROPERTIES ..............................................................................225 SunGuardTM Duplexed Aluminum XLPE UL Type PV Photovoltaic Wire 2kV....................234

Copper PVC UL TFFN/TFN 90°C 600V...................................................................................226 Copper PVC/Nylon UL THHN/THWN-2 90°C Dry 75°C Wet 600V ........................................218 UF-B Underground Feeder 600V ..........................................................................................220 Copper XLP UL XHHW-2 600V..............................................................................................222 Copper XLP Type SIS VW-1 90°C 600V ................................................................................221 Copper XLP UL RHH/RHW-2 or USE-2 90°C 600V...............................................................223 SunGuardTM Copper XLPE UL Type PV Photovoltaic Wire 600V ........................................203 Copper EPR/CPE UL RHH/RHW-2 or USE-2 90°C 600V .......................................................224 Copper XLP UL RHH/RHW-2 or USE-2 90°C 2kV .................................................................233 DLO Copper EPR/CPE UL TRJJ/RHW-2 2kV..........................................................................709 SunGuardTM Copper XLPE Type PV Photovoltaic Wire 2kV ...............................................231 LSZH XLPO/LSZH XLPO UL Type RHH/RHW-2/USE-2 Unshielded 600V ...........................241 SunGuardTM Tracker Motor Cable UL Type PV/TC 2kV ........................................................239

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

200 20180201

LOW VOLTAGE CABLES

SunGuard™ Paralleled Aluminum XLPE UL Type PV Photovoltaic Wire 2kV ...................243 Copper PVC UL THW-2 75°C 600V ........................................................................................219

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

TowerGuard CCA® Power Cable 2kV UL RHH/RHW-2 Copperclad Aluminum Conductor/90°C Wet or Dry For Cable Tray Use — Sunlight Resistant — For Direct Burial U.S. Patent No. 8,618,688

Construction Nominal voltage: RHH/RHW-2 2000V UL Conductor: The conductor shall be a flexible Copperclad Aluminum (CCA), an electrical conductor that has an outer sleeve of copper metallurgically bonded to a solid aluminum core. The combination of these two metals makes it uniquely suited to many electrical applications where weights to electrical conductivity issues are important. This bimetallic wire is much lighter than copper and only slightly heavier than bare aluminum. The density of CCA is about 35% lighter than copper. CCA conducts like copper for AC frequencies. This product meets or exceeds the minimum requirements set forth in ASTM B 566 04. Separator: A suitable tape separator between the conductor and insulation. Insulation: Ethylene-propylene rubber (EPR) type EP, meeting UL and ICEA requirements for 90ºC. Jacket: A heavy duty, thermosetting CPE in accordance with ICEA S-95-658 NEMA WC70 Jacket Color: Black Print Legend: TOWERGUARD CCA SIZE AWG OR KCMIL) CU CLAD AL UL 217923 RHH or RHW-2 2000V SUN RES OIL RES U.S. Patent No. 8,618,688 (SEQUENTIAL FOOTAGE MARKER)

Specifications • ICEA S-95-658 / NEMA WC70 • UL Standard 44 • ASTM B 566 • ASTM B 172 Product Features • 35% less expensive than copper cables with equal ampacity • Flexible cable design — TowerGuard RHH or RHW-2 can bend to a radius of 6 times the O.D. without impairing the insulation. • Surface printed for easy identification • 35% lighter weight and easier to install than copper cables with equal ampacity • Ozone, sunlight, oil, grease, weather, water, chemical and abrasion resistant jacket • 90°C (dry) 90°C (wet) • No scrap value (theft deterrent) • Sequential footage markers • U.S. Patent No. 8,618,688 Terminals and Splices Testing has been competed using TowerGuard CCA with BURNDY® aluminum HYLUGTM terminals an HYLINKTM splices. Both are UL Listed for use on copperclad aluminum cable. Wire

CCA4/0 CCA250 CCA350 CCA500 CCA600 CCA750 CCA800 CCA900 CCA1000

Size

4/0awg 250kcmil 350kcmil 500kcmil 600kcmil 750kcmil 750kcmil 900kcmil 1000kcmil

BURNDY LUG PART NUMBER 1 hole 2 hole Butt Splice YA30A1 YA30A3 YS30A1 YA31A1 YA31A3 YS31A1 YA34A1 YA34A3 YS34A1 YA36A1 YA36A3 YS36A1 YA39A1 YA39A5 YS39A1 YA44A1 YA44A3 YS44A1 YA44A1 YA44A3 YS44A1 YA45A5 YS45A1 YA45A5 YS45A1

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

201 201400924

LOW VOLTAGE CABLES

Applications This cable is intended for fixed installation in wind turbine towers. Good resistance to temperatures, oils, ozone and fire. This cable is intended for use in solar power generation applications to connect the inverter to transformer where high flexibility is required, commonly applied to prefabricated inverter and transformer skids. Additionally, this cable is appropriate for tight battery applications, as well as superior alternatives to battery cable. TowerGuard CCA can also be used for secondary voltage resistance welding leads and in power supply applications not exceeding 2000V volts. Not commonly for use on DC power circuits, please consult AWG for your applications.

NOTES

LOW VOLAGE CABLES

Item #

Conductor Stranding Nominal Nominal Nominal Size Conductor Insulation Jacket AWG/kcmil Diameter Thickness Thickness (in) (mil) (mil)

CCA4/0-01TWRGRD 4/0 CCA250-01TWRGRD 250 CCA350-01TWRGRD 350 CCA500-01TWRGRD 500 CCA600-01TWRGRD 600 CCA750-01TWRGRD 750 CCA800-01TWRGRD 800 CCA900-01TWRGRD 900 CCA1000-01TWRGRD 1000

329 399 551 779 925 1184 1258 1406 1554

0.584 0.650 0.764 0.909 0.993 1.124 1.158 1.225 1.288

65 75 75 75 90 90 90 90 90

45 65 65 65 65 65 65 65 65

Nominal Cable Diameter (in)

Copper Weight /MFT (lb)

Aluminum Weight /MFT (lb)

Net Cable Weight /MFT (lb)

Ampacity* 90°C Free Air

Ampacity** 90°C Duct

0.802 0.930 1.044 1.189 1.273 1.434 1.468 1.535 1.598

96 116 161 227 270 345 367 416 453

165 200 277 391 464 595 632 706 780

458 590 756 1017 1301 1462 1521 1733 1850

315 355 455 545 615 700 725 785 845

205 230 280 350 385 435 450 480 500

*Ampacity is calculated based on a single conductor in free air with a 90°C conductor temperature and 30°C ambient, per 2008 NEC, Table 310-17 **Ampacity is calculated based on 3 conductors in a duct with a 90°C conductor temperature and 30°C ambient, per 2008 NEC, Table 310-16

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 201 201400924

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Aluminum HYLUG™ Terminal and HYLINK™ Splice Connectors Types YA-A and YS-A, 90°C, up to 35 kV

® Listed Wire Connector

• Dieless tools and nest/indenter tools will have a completed crimp similar to illustration shown.

Die Information Die Die Index Type

4.Insert the conductor all the way into the barrel and crimp the connector using a die index number and color marked on the connector. Be sure orientation is correct before crimping.

• Other die sets listed have a completed crimp of a more circumferential nature and will look similar to this illustration.

BUNDY® Installation Tooling (# Crimps) Hydraulic Y35 Y46(1) Y45(1) Y60 Y39 PAT46(1) Y750 PAT750

5.Wire brush any unplated surface to which the HYLUG™ will be attached and coat the contact surface with PENETROX™ joint compound. 6.Remove any excess PENETROX™ before taping.

Catalog # Conductor HYLUGTM HYLINKTM Size Terminal Splice Al or CU Concentric Compressed Compact

Color Code

YA8CA-

YS8CA-

8 AWG

BLUE

374

DIE SET

X8CART(2)

W374(1) U8CABT(1)

U8CABT(1) U8CABT(1)

-

MRC840AL(1) MY29-3(1)

YA6CA-

YS6CA-

6 AWG

GRAY

346 161

DIE SET

X6CART(2) X161(2)

U6CABT(1) W161(1) U161(1)

U6CABT(1) U6CABT(1) U161(1) U161(1)

-

MRC840AL(1) MY29-3(1)

YA4CA-

YS4CA-

4 AWG

GREEN

375

DIE SET 162

X4CART(3) -

U4CABT(1) W162(3) U162(1)

U4CABT(1) U4CABT(1) U162(1) U162(1)

-

MRC840AL(2) MY29-3(1)

YA2CA-

YS2CA-

2 AWG

PINK

348 163 239

DIE SET

X2CART(4) X239(4)

W163(3) W239(2)

U2CAB(1) U163(1) U239(1)

U2CABT(1) U2CABT(1) U163(1) U163(1) U239(1) U239(1)

-

MRC840AL(2) MY29-3(2)

YA1CA-

YS1CA-

1 AWG

GOLD

371 163

DIE SET

X1CART(3) -

U1CART(1) W163(3) U163(1)

U1CART(1) U1CART(1) U163(1) U163(1)

-

MRC840AL(2) MY29-3(2)

Mechanical OUR840 MD6 PATMD6 PAT600

Wire Dieless Strip Mechanical Hydraulic Length

PAT644(1) Y644(1) PAT81KFT(1) Y81KFT(1) PAT644(1) Y644(1) PAT81KFT(1) Y81KFT(1) PAT644(1) Y644(1) PAT81KFT(1) Y81KFT(1) PAT644(1) Y644(1) PAT81KFT(2) Y81KFT PAT644(1) Y644(1) PAT81KFT(2) Y81KFT(2)

3/4”

7/8”

1”

1-1/4”

1-1/16”

① Catalog # PUADP-1 Adaptor is required to use "U" dies in Y46 series tools ② Catalog # PT6515 Adaptor is required to use "U" dies in Y45 series tools ③ CCA DLO Conductor to be installed with Y644/PAT644 series of tools only

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

242 20170318

LOW VOLTAGE CABLES

1. Use a HYLUG™ termi2.Strip the wire insulation 3. Always wire brush the nal or HYLINK™ splice without nicking or ringstripped portion of the marked for the wire size ing the conductor conductor to remove to be used. Never use a strands. oxide film. copper crimp connector on aluminum wire.

LOW VOLAGE CABLES

Aluminum HYLUG™ Terminal and HYLINK™ Splice Connectors Types YA-A and YS-A, 90°C, up to 35 kV Die Information Die Die Index Type

BUNDY® Installation Tooling (# Crimps) Hydraulic Y35 Y46(1) Y45(1) Y60 Y39 PAT46(1) Y750 PAT750

Catalog # Conductor HYLUGTM HYLINKTM Size Terminal Splice Al or CU Concentric Compressed Compact

Color Code

YA25A-

YS25A-

1/0 AWG

TAN

296 241

DIE SET

X25ART(4) X241(4)

U25ART(1) W241(2) U241(1)

U25ART(1) U241(1)

U25ART(1) U241(1)

YA26A-

YS26A-

2/0 AWG

OLIVE

297 245

DIE SET

X26ART(4) X245(4)

U26ART(2) W245(3) U245(1)

U26ART(2) U245(1)

U26ART(2) U245(1)

YA27A-

YA27A-

3/0 AWG

RUBY

467 166

DIE SET

X27ART(4) -

U27ART(2) W166(4) U166(2)

U27ART(2) U166(2)

U27ART(2) U166(2)

W660(3)

U28ART2 U6602

P30D(1) P34PR-5 U28ART(2) U660(2)

U28ART(2) U660(2)

Mechanical OUR840 MD6 PATMD6 PAT600

467 YA28A-

YS28A-

4/0AWG

WHITE

NEST INDENTOR 298 DIE SET X28ART(6) 660 X660(8) 298

YA29A-

YA30A-

YA31A-

YA32A-

YA34A-

YS29A-

YS30A-

YS31A-

YS32A-

YS34A-

250 kcmil

300 kcmil (4/0AWG CCA DLO③ [329/22])

500 kcmil (350 kcmil CCA DLO③ [551/22])

MRC840AL(2) MY29-3(2)

PAT644(1) 1-3/16” Y644(1) PAT81KFT(2) Y81KFT(2) MRC840AL(3) PAT644(1) 1-3/8” MY29-3(2) Y644(1) PAT81KFT(2) Y81KFT(2) MRC840AL(3) PAT644(1) 1-1/2” MY29-3(2) Y644(1) PAT81KFT(2) Y81KFT(2) MRC840AL(3) PAT644(1) 1-5/8” MY29-3(2) Y644(1) PAT81KFT(2) Y81KFT(2) L29ART(1) PAT644(1) 1-5/8” Y644(1) PAT81KFT(2) Y81KFT(2) -

RED

NEST INDENTOR 324 DIE SET

-

-

U29ART(2)

P31D(1) P34PR-5 U29ART(2)

U29ART(2)

-

-

U30ART(2)

P32D(1) P34PR-5 U30ART(2)

-

BLUE

NEST INDENTOR DIE SET

U30ART(2) L30ART(1)

-

NEST INDENTOR 299 DIE SET

-

-

U31ART(2)

P34D(1) P48PR-1 U31ART(2)

U31ART(2)

-

NEST INDENTOR DIE SET

-

-

U32ART(4)

U32ART(4)

P35D(1) P48PR-1 U32AR(2) L32ART(2)

-

NEST INDENTOR 300 DIE SET

-

-

U34ART(4)

P35D(1) P48PR-1 U34ART(4)

U34ART(4) L34ART(2)

-

NEST INDENTOR

-

-

-

P39D(1) P48PR-1

350 kcmil BROWN (250 kcmil CCA DLO③ [399/22])

400 kcmil

-

Wire Dieless Strip Mechanical Hydraulic Length

GREEN

PINK

470

472

-

-

-

PAT644(1) 1-3/4” Y644(1) PAT81KFT(2) Y81KFT(2)

PAT644(1) 2-1/8” Y644(1) PAT81KFT(3) Y81KFT(3)

PAT644(1) 2-1/2” Y644(1) PAT81KFT(4) Y81KFT(4)

PAT644(1) 2-5/8” Y644(1) PAT81KFT(4) Y81KFT(4)

-

① Catalog # PUADP-1 Adaptor is required to use "U" dies in Y46 series tools ② Catalog # PT6515 Adaptor is required to use "U" dies in Y45 series tools ③ CCA DLO Conductor to be installed with Y644/PAT644 series of tools only

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 242 20170318

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Aluminum HYLUG™ Terminal and HYLINK™ Splice Connectors Types YA-A and YS-A, 90°C, up to 35 kV Catalog # Conductor HYLUGTM HYLINKTM Size Terminal Splice Al or CU Concentric Compressed Compact YA36A-

YS36A-

600 kcmil (500 kcmil CCA DLO③ [779/22]

Color Code

BLACK

YA39A-

YA40A-

YA42A-

YA44A-

YA45A-

YA46AYA47AYA48A-

YS40A-

800 kcmil

GRAY

YS42A-

900 kcmil GRAY ALUMINUM ONLY YS44A- 1000 kcmil BROWN (750/800 kcmil CCA DLO③ [1184/1258])

YS45A-

YS46AYS47AYS48A-

1250 kcmil BROWN (900/1000 kcmil CCA DLO③ [1406/1554]) 1500 kcmil 1750 kcmil 2000 kcmil

BLUE WHITE RED

473

DIE SET

Mechanical OUR840 MD6 PATMD6 PAT600

BUNDY® Installation Tooling (# Crimps) Hydraulic Y35 Y46(1) Y45(1) Y60 Y39 PAT46(1) Y750 PAT750

-

-

NEST INDENTOR 936 DIE SET

-

--

301

-

-

-

P39ART(4)

S39ART(4) L39ART(2)

-

NEST INDENTOR 474 DIE SET

-

-

-

P45D(2) P48PR-1 P40ART(4)

S40ART(4) L40ART(2)

-

NEST INDENTOR 303 DIE SET

-

-

-

-

-

U42ART(4)

P45D(4) P48PR-1 U42ART(4)

U42ART(4)

-

302

-

-

-

P44ART(4)

S44ART(4) L44ART(2)

-

NEST INDENTOR 302 DIE SET

-

-

-

NO NEST P48PR-1(2) P44ART(4)

S44ART(4) L44ART(2)

-

NEST INDENTOR 478 DIESET 587 DIESET 479 DIESET

-

-

-

NO NEST P48PR-1(2) -

DIE SET

DIE SET

U36ART(4)

U36ART(4)

Wire Dieless Strip Mechanical Hydraulic Length

U36ART(4) L36ART(2)

-

P44D(2) P48PR-1 U39ART-2(4) U39ART-2(4) U39ART-2(4) L39ART-2(2)

-

-

-

L46ART(2) L47ART(2) L48ART(2)

-

PAT644(1) 2-7/8” Y644(1) PAT81KFT(4) Y81KFT(4)

PAT644(1) 2-7/8” Y644(1) PAT81KFT(4) Y81KFT(4) PAT644(1) 2-7/8” Y644(2) PAT81KFT(4) Y81KFT(4) Y644MBH(1) 3”

PAT644(2) Y644(2)

2-7/8”

Y644MBH ONLY (1)

3-1/8”

Y644MBH ONLY (1)

3-1/8”

-

3-3/4” 4-3/8” 4-1/8”

① Catalog # PUADP-1 Adaptor is required to use "U" dies in Y46 series tools ② Catalog # PT6515 Adaptor is required to use "U" dies in Y45 series tools ③ CCA DLO Conductor to be installed with Y644/PAT644 series of tools only

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

242 20170318

LOW VOLTAGE CABLES

YS39A- 700/750 kcmil YELLOW (600 kcmil CCA DLO③ [925/22]) YA39AM- YS39AM- 700 kcmil RED or 750 kcmil

Die Information Die Die Index Type

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 20X 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Aluminum XLP UL XHHW-2 600V 90°C Wet or Dry Applications Type XHHW-2 is intended for use as general purpose wiring in air conduit or other recognized raceways for services, feeder and branch circuit wiring as specified in the National Electric Code at a maximum conductor temperature of 90°C in wet or dry locations. Construction Compact stranded 8000 Series aluminum alloy conductor, black abrasion, heat and moisture resistant cross-linked polyethylene insulation. Standards • UL 44 • Federal specifications JC-30B NEC, ASTM B 800, B 801, B 836 as applicable. Ampacity To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.

XHHW-2-0008 XHHW-2-0006 XHHW-2-0004 XHHW-2-0002 XHHW-2-0001 XHHW-2-01/0 XHHW-2-02/0 XHHW-2-03/0 XHHW-2-04/0 XHHW-2-0250 XHHW-2-0300 XHHW-2-0350 XHHW-2-0400 XHHW-2-0500 XHHW-2-0600 XHHW-2-0700 XHHW-2-0750 XHHW-2-1000

Size AWG or MCM

Stranding

Insulation Thickness (mil)

Outside Diameter (in)

Weight /MFT (lb)

Ampacity 90°C

8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 700 750 1000

7 7 7 7 18 18 18 18 18 35 35 35 35 35 58 58 58 58

45 45 45 45 55 55 55 55 55 65 65 65 65 65 80 80 80 80

.230 .260 .305 .360 .415 .450 .490 .540 .590 .655 .705 .750 .795 .870 .980 1.040 1.075 1.230

29 40 58 86 109 132 162 199 245 294 347 398 450 552 672 774 825 1077

45 60 75 100 115 135 150 175 205 230 255 280 305 350 385 420 435 500

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

205 20140921

LOW VOLTAGE CABLES

Item #

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Aluminum XLP UL RHH/RHW-2 or USE-2 600V 90°C Wet or Dry Applications Type RHH-RHW-2 or USE-2 building wire and service cable is recognized for use as general purpose wiring at a maximum conductor temperature of 90°C in wet or dry locations for installation in air, conduit or other recognized raceways and for direct burial in circuits not exceeding 600V. Construction Compact stranded 8000 Series aluminum alloy conductor, black abrasion, heat, moisture and sunlight resistant cross-linked polyethylene insulation. Standards • UL Standards 44 (RHW or RHH) • UL standard 854 (USE-2) • Federal specification JC-30B NEC • ASTM B800, B801, B836 as applicable.

Item #

USE-RHH-RHW-2-0008 USE-RHH-RHW-2-0006 USE-RHH-RHW-2-0004 USE-RHH-RHW-2-0002 USE-RHH-RHW-2-0001 USE-RHH-RHW-2-01/0 USE-RHH-RHW-2-02/0 USE-RHH-RHW-2-03/0 USE-RHH-RHW-2-04/0 USE-RHH-RHW-2-0250 USE-RHH-RHW-2-0300 USE-RHH-RHW-2-0350 USE-RHH-RHW-2-0400 USE-RHH-RHW-2-0500 USE-RHH-RHW-2-0600 USE-RHH-RHW-2-0700 USE-RHH-RHW-2-0750 USE-RHH-RHW-2-1000

Size AWG or MCM

Stranding

Insulation Thickness (mil)

Outside Diameter (in)

Weight /MFT (lb)

Ampacity 90°C

8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 700 750 1000

7 7 7 7 18 18 18 18 18 35 35 35 35 35 58 58 58 58

60 60 60 60 80 80 80 80 80 95 95 95 95 95 110 110 110 110

.266 .290 .334 .390 .460 .500 .540 .590 .635 .710 .760 .810 .850 .930 1.035 1.100 1.130 1.280

37 49 65 94 125 150 181 220 268 320 374 428 482 591 715 821 873 1132

45 60 75 100 115 135 150 175 205 230 255 280 305 350 385 420 435 500

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

204 20140921

LOW VOLTAGE CABLES

Ampacity To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

TowerGuard® Aluminum XLP UL RHH/RHW-2 or USE-2 2kV 90°C Applications • For use from the lower control box at the base of the wind power tower and out to the stepup transformer through conduit • General purpose building wire for use in air and approved raceways • Industrial environments where superior insulation toughness and chemical resistance is required • Maximum operating temperature not to exceed 90°C in wet or dry locations • For use in free air, raceways or direct burial in accordance with NEC.

Insulation: • Flame-retardant Cross-Linked Polyethylene (XLPE) — Black Print: • TOWERGUARD XLP AWG/KCMIL TYPE RHH/RHW-2 SR CT (UL) 2000V (MM/YYYY) SEQUENTIAL FOOTAGE MARK • Sizes smaller than 1/0 AWG do not include the “CT” marking

Item #

TGXL-08 TGXL-06 TGXL-04 TGXL-02 TGXL-01 TGXL-1/0 TGXL-2/0 TGXL-3/0 TGXL-4/0 TGXL-250 TGXL-350 TGXL-500 TGXL-600 TGXL-750 TGXL-1000

Features • Rated at 90°C wet or dry • UV resistant — black is marked SR • Excellent electrical, thermal and physical properties • Excellent resistance to moisture • Excellent resistance to crush, compression cuts and heat deformation Packaging • All produced or cut-to-order material will be shipped on non-returnable wooden reels unless specifically requested • Cable is stocked in 3 colors - Black with 3 Red Stripes, Black with 3 Yellow Stripes, Black with 3 Orange Stripes.

Conductor Size AWG/kcmil

No. of Wires1

Conductor Diameter (in)

Insulation Thickness (mil)

Cable Diameter (in)

Aluminum Weight /MFT (lb)

Net Weight /MFT (lb)

Ampacity 90°C

8 6 4 2 1 1/0 2/0 3/0 4/0 250 350 500 600 750 1000

7 7 7 7 18 18 18 18 18 35 35 35 58 58 58

0.134 0.169 0.213 0.268 0.299 0.336 0.376 0.423 0.475 0.520 0.616 0.736 0.813 0.908 1.060

70 70 70 70 90 90 90 90 90 105 105 105 120 120 120

0.285 0.320 0.360 0.420 0.495 0.530 0.580 0.615 0.665 0.745 0.840 0.960 1.075 1.175 1.325

16 25 39 62 79 99 125 158 199 235 329 471 565 706 941

38 51 72 100 134 160 192 229 281 336 449 605 736 901 1168

45 60 75 100 115 135 150 175 205 230 280 350 385 435 500

Dimensions and weights are nominal; subject to industry tolerances. 1Minimum number of wires utilized for compact-strand constructions.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

202 20151123

LOW VOLTAGE CABLES

Product Construction Conductor: • 8 AWG thru 1000 kcmil compacted aluminum ACM (AA-8000 Series)

Compliances • National Electric Code (NEC) • UL 44 Stranded for rubber-insulated wires and cables • “CT” for 1/0 AWG and larger in accordance with NEC • ICEA S-95-685/NEMA WC70 • UL listed as Type RHH/RHW-2 • OSHA acceptable

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Towerguard Plus® Class 33 Aluminum XLPE 105°C 2kV Applications • For use from the lower control box at the base of the wind power tower and out to the stepup transformer through conduit • General purpose building wire for use in air and approved raceways • Industrial environments where superior insulation toughness and chemical resistance is required • Maximum operating temperature not to exceed 105 ºC in wet or dry locations • For use in free air, raceways or direct burial in accordance with NEC.

Item #

A4/0-01XLP2BLK105 A500-01XLP2BLK105 A750-01XLP2BLK105 A1000-01XLP2BLK105

Features • Rated at 105 ºC wet or dry • UV resistant - black is marked SR • Smaller cable O.D. • Excellent electrical, thermal and physical properties • Excellent resistance to moisture • Excellent resistance to crush, compression cuts and heat deformation Packaging • Material can be produced and cut to length upon request • All produced or cut-to-order material will be shipped on non-returnable wooden reels unless specifically requested

Conductor Size AWG or kcmil

Number of Wires1

Conductor Diameter (in)

Insulation Thickness (mil)

Cable Diameter (in)

Aluminum Weight (lb/MFT)

Net Weight (lb/MFT)

4/0 500 750 1000

18 35 58 58

0.475 0.736 0.908 1.060

90 105 120 120

0.665 0.960 1.175 1.325

199 471 706 941

281 605 901 1168

Dimensions and weights are nominal: subject to industry tolerances. 1Minimum number of wires utilized for compact-strand constructions.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

240 20151123

LOW VOLTAGE CABLES

Construction Conductor: 8 AWG thru 1000 kcmil compacted aluminum ACM (AA-8000 Series) Conductor. Insulation is Class 33 Flame-retardant CrossLinked Polyethylene (XLPE) Black. Colors: Black, Red, Blue, Green, Orange, Yellow Brown. 3 extruded stripes and other colors are available upon request. Print Legend:TOWERGUARD PLUS® AWG/KCMIL AL XLPE 2000V 105 ºC (MM/YYYY) SEQUENTIAL FOOTAGE MARK

Standards • UL 1581 • ICEA S-95-685/NEMA WC70 • CSA standard C 22.2 No. 38

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

SunGuard™ Aluminum XLPE UL Type PV Photovoltaic Wire 600V UL Type PV/USE-2 or 2kV RHH or RHW-2 or c(UL) RWU90, 1kV, 90°C Applications Single conductor, sunlight-resistant, photovoltaic wire rated 90°C wet or dry, 600 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70. • For use in free air, raceways or direct burial in accordance with NEC.

Compliances • UL 4703 Type PV • National Electrical Code (NEC) • ICEA S-95-658/NEMA WC70 • UL 44 Type RHH or RHW-2 • UL 854 Type USE-2 • c(UL) RWU90 1 kV Packaging Material cut to length and shipped on non-returnable wood reels.

Options Colored phase ID stripes available on request Multi-plexing available on request

Item #

Conductor Size (AWG/ kcmil) 8 AWG - 1000 kcmil CONDUCTORS A8-01PVX0700* 8 A6-01PVX0700* 6 A4-01PVX0700* 4 A2-01PVX0700* 2 A1-01PVX1900* 1 A1/0-01PVX190* 1/0 A2/0-01PVX1900* 2/0 A3/0-01PVX1900* 3/0 A4/0-01PVX1900* 4/0 A250-01PVX3700* 250 A300-01PVX3700* 300 A350-01PVX3700* 350 A400-01PVX3700* 400 A500-01PVX3700* 500 A600-01PVX6100* 600 A750-01PVX6100* 750 A1000-01PVX6100* 1000

Conductor Stranding

7/.0486 7/.0612 7/.0772 7/.0974 19/.0664 19/.0745 19/.0837 19/.0940 19/.1055 37/.0822 37/.0900 37/.0972 37/.1040 37/.1159 61/.0992 61/.1109 61/.1280

Nominal Conductor O.D. (in) (mm)

0.134 0.169 0.213 0.268 0.299 0.336 0.376 0.423 0.475 0.520 0.570 0.616 0.659 0.736 0.813 0.908 1.060

3.40 4.29 5.41 6.81 7.59 8.53 9.55 10.74 12.07 13.21 14.48 15.65 16.74 18.69 20.65 23.06 26.92

Minimum Average Insulation Thickness (in) (mm)

0.080 0.080 0.080 0.080 0.095 0.095 0.095 0.095 0.095 0.110 0.110 0.110 0.110 0.110 0.125 0.125 0.125

2.03 2.03 2.03 2.03 2.41 2.41 2.41 2.41 2.41 2.79 2.79 2.79 2.79 2.79 3.18 3.18 3.18

Nominal Cable Diameter (in) (mm)

0.298 0.333 0.377 0.432 0.495 0.532 0.572 0.619 0.671 0.746 0.796 0.842 0.885 0.962 1.069 1.164 1.316

7.57 8.46 9.58 10.97 12.57 13.51 14.53 15.72 17.04 18.95 20.22 21.39 22.48 24.43 27.15 29.57 33.43

Aluminum Weight /MFT /km (lb) (Kg)

Net Weight /MFT /km (lb) (Kg)

16 25 39 63 79 99 125 158 199 262 282 329 376 471 565 706 914

49 64 85 117 153 180 214 256 307 399 430 487 544 656 798 963 1210

23 37 58 93 117 148 186 235 296 390 420 490 560 701 841 1051 1360

73 95 127 174 227 268 318 380 456 594 640 725 810 977 1187 1433 1801

Dimensions and weights are nominal; subject to industry tolerances.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

230 20170107

LOW VOLTAGE CABLES

Construction Conductor: 8 AWG thru 1000 kcmil compact aluminum ACM (8000 series) Insulation: Flame-retardant Cross-Linked Polyethylene (XLPE), black Print: AWG (PLANT OF MFG) SUNGUARD™ 600 V PV WIRE OR USE-2 OR 2000 V RHH OR RHW-2 (SIZE) AL ACM 90˚C WET OR DRY SUN RES (UL) -40˚C c(UL) RWU90 1000 V DIR BUR MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE MARK

Features • Rated 90°C wet and dry • Deformation-resistant at high temperatures • Excellent moisture resistance, exceeds UL 44 • Stable electrical properties over a broad temperature range • Excellent resistance to crush and compression cuts • Resistant to most oils and chemicals • UV/sunlight-resistant • Meets cold bend test at -40°C

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

SunGuard™ Aluminum XLPE UL Type PV Photovoltaic Wire 2kV UL Type PV/RHH or RHW-2 or 600V USE-2 or c(UL) RWU90, 1kV 90°C PHYSICAL & ELECTRICAL PROPERTIES Applications Single conductor, sunlight-resistant, photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70. • For use in free air, raceways or direct burial in accordance with NEC.

Options Colored phase ID stripes available on request Multi-plexing available on request Features • Rated 90°C wet and dry • Deformation-resistant at high temperatures • Excellent moisture resistance, exceeds UL 44

Item #

PHYSICAL PROPERTIES A8-01PV2X0700* A6-01PV2X0700* A4-01PV2X0700* A2-01PV2X0700* A1-01PV2X1900* A1/0-01PV2X190* A2/0-01PV2X1900* A3/0-01PV2X1900* A4/0-01PV2X1900 A250-01PV2X3700 A300-01PV2X3700 A350-01PV2X3700 A400-01PV2X3700 A500-01PV2X3700 A600-01PV2X6100* A750-01PV2X6100* A1000-01PV2X6100*

Conductor Size (AWG/ kcmil)

Conductor Stranding

8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 1000

7/.0486 7/.0612 7/.0772 7/.0974 19/.0664 19/.0745 19/.0837 19/.0940 19/.1055 37/.0822 37/.0900 37/.0972 37/.1040 37/.1159 61/.0992 61/.1109 61/.1280

Nominal Conductor O.D. (in) (mm)

0.134 0.169 0.213 0.268 0.299 0.336 0.376 0.423 0.475 0.520 0.570 0.616 0.659 0.736 0.813 0.908 1.060

3.40 4.29 5.41 6.81 7.59 8.53 9.55 10.74 12.07 13.21 14.48 15.65 16.74 18.69 20.65 23.06 26.92

Minimum Average Insulation Thickness (in) (mm)

0.085 0.085 0.085 0.085 0.105 0.105 0.105 0.105 0.105 0.120 0.120 0.120 0.120 0.120 0.135 0.135 0.135

2.16 2.16 2.16 2.16 2.67 2.67 2.67 2.67 2.67 3.05 3.05 3.05 3.05 3.05 3.43 3.43 3.43

Compliances • ASTM B800 - 05(2011) Standard Specification for 8000 Series Aluminum Alloy Wire for Electrical Purposes - Annealed and Intermediate Tempers • ASTM B801 - 07(2012) Standard Specification for Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy for Subsequent Covering or Insulation • ASTM B836 - 00(2011) Standard Specification for Compact Round Stranded Aluminum Conductors Using Single Input Wire Construction • UL 4703 Type PV • National Electrical Code (NEC) • ICEA S-95-658/NEMA WC70 • UL 44 Type RHH or RHW-2 • UL 854 Type USE-2 • c(UL) RWU90 1kV Packaging Material cut to length and shipped on non-returnable wood reels.

Nominal Cable Diameter (in) (mm)

0.310 0.345 0.389 0.444 0.515 0.552 0.592 0.639 0.691 0.766 0.816 0.862 0.905 0.982 1.089 1.184 1.336

7.87 8.76 9.88 11.28 13.08 14.02 15.04 16.23 17.55 19.46 20.73 21.89 22.99 24.94 27.66 30.07 33.93

Aluminum Weight /MFT /km (lb) (Kg)

Net Weight /MFT /km (lb) (Kg)

16 25 39 63 79 99 125 158 199 262 282 329 376 471 565 706 914

52 67 90 122 162 191 225 267 319 413 445 503 561 675 818 985 1235

23 37 58 93 117 148 186 235 296 390 420 490 560 701 841 1051 1360

78 100 133 182 241 284 334 398 475 615 663 749 835 1004 1217 1466 1838

Dimensions and weights are nominal; subject to industry tolerances.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

225 20170107

LOW VOLTAGE CABLES

Construction Conductor: 8 AWG thru 1000 kcmil compact aluminum ACM (8000 series) Insulation: Flame-retardant Cross-Linked Polyethylene (XLPE), black Print: AWG (PLANT OF MFG) SUNGUARD™ 2000 V PV WIRE OR RHH OR RHW-2 OR 600 V USE-2 (SIZE) AL ACM 90˚C WET OR DRY SUN RES (UL) -40˚C c(UL) RWU90 1000 V DIR BUR MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE MARK

• Stable electrical properties over a broad temperature range • Excellent resistance to crush and compression cuts • Resistant to most oils and chemicals • UV/sunlight-resistant • Meets cold bend test at -40°C

SunGuard™ Aluminum XLPE UL Type PV Photovoltaic Wire Type PV/RHH or RHW-2 2kV or 600V USE-2 PHYSICAL & ELECTRICAL PROPERTIES

LOW VOLAGE CABLES

Item #

ELECTRICAL PROPERTIES A8-01PV2X0700* A6-01PV2X0700* A4-01PV2X0700* A2-01PV2X0700* A1-01PV2X1900* A1/0-01PV2X190* A2/0-01PV2X1900* A3/0-01PV2X1900* A4/0-01PV2X1900 A250-01PV2X3700 A300-01PV2X3700 A350-01PV2X3700 A400-01PV2X3700 A500-01PV2X3700 A600-01PV2X6100* A750-01PV2X6100* A1000-01PV2X6100*

Conductor Size (AWG/ kcmil)

DC Resistance of Conductor ohms/km @ 20°C

Positive Sequence @90°C of Conductor Ohms/km

Capacitance x10-9F/m

Three Core Paralleled Inductance mH/km

Three Core Paralleled Positive Sequence Reactance H/km

Three Core Paralleled Zero-Sequence Reactance H/km

8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 1000

3.446 2.168 1.363 0.857 0.680 0.539 0.428 0.3389 0.2690 0.2277 0.1896 0.1624 0.1424 0.1139 0.0948 0.0758 0.0568

4.39 2.76 1.74 1.093 0.867 0.687 0.545 0.432 0.343 0.291 0.242 0.208 0.182 0.146 0.122 0.0980 0.0743

0.151 0.178 0.210 0.251 0.233 0.255 0.279 0.307 0.338 0.328 0.354 0.385 0.407 0.447 0.441 0.485 0.555

0.543 0.517 0.495 0.475 0.483 0.474 0.465 0.457 0.449 0.451 0.446 0.444 0.440 0.434 0.435 0.429 0.422

0.1705 0.1625 0.1555 0.1493 0.1518 0.1488 0.1461 0.1435 0.1411 0.1418 0.1400 0.1396 0.1384 0.1365 0.1366 0.1349 0.1326

0.053 0.045 0.038 0.032 0.034 0.031 0.029 0.026 0.024 0.025 0.023 0.022 0.021 0.019 0.019 0.018 0.015

AA8000 Maximum Electrical Resistivity Temperature 20℃ AWG size 8 7 6 5 4 3 2 1 1/0 2/0 3/0 4/0

Ω/1000ft 1.07 0.8495 0.674 0.5346 0.4238 0.3361 0.2665 0.2113 0.1676 0.1329 0.1055 0.836

Ω/1000m 3.515 2.787 2.211 1.754 1.39 1.103 0.8745 0.6934 0.5498 0.4361 0.3459 0.2743

AWG size 250kmil 300 350 400 450 500 550 600 700 750 800 900 1000

Ω/1000ft 0.07076 0.05897 0.05054 0.04423 0.03931 0.03537 0.03216 0.02948 0.02527 0.02358 0.02211 0.01966 0.01769

Ω/1000m 0.2322 0.1935 0.1659 0.145 0.1289 0.1161 0.1055 0.09673 0.08291 0.07738 0.07254 0.06448 0.05804

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 225 20170107

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

SunGuard™ Duplexed Aluminum XLPE UL Type PV Photovoltaic Wire 2kV Applications Duplexed conductors are sunlight-resistant, photovoltaic wire rated 90°C wet or dry, 2000 volts for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70. • For use in free air, raceways or direct burial in accordance with NEC.

Item #

A8-02PV2X0700 A6-02PV2X0700 A4-02PV2X0700 A2-02PV2X0700 A1-02PV2X1900 A1/0-02PV2X190 A2/0-02PV2X1900 A3/0-02PV2X1900 A4/0-02PV2X1900 A250-02PV2X3700 A300-02PV2X3700 A350-02PV2X3700 A400-02PV2X3700 A500-02PV2X3700 A600-02PV2X6100 A750-02PV2X6100 A1000-02PV2X6100

Standards • Rated 90°C wet and dry • Deformation-resistant at high temperatures • Excellent moisture resistance, exceeds UL 44 • Stable electrical properties over a broad temperature range • Excellent resistance to crush and compression cuts • Resistant to most oils and chemicals • UV/sunlight-resistant • Meets cold bend test at -40ºC • Material cut to length and shipped on non-returnable wood reels.

Conductor Size (AWG/kcmil)

Single Conductor Stranding

Nominal Conductor OD (in)

Minimum Average Insulation Thickness (in)

Duplexed Cable Diameter (in)

Aluminum Weight (lb/MFT)

Net Weight (lb/MFT)

8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 1000

7/.0486 7/.0612 7/.0772 7/.0974 19/.0664 19/.0745 19/.0837 19/.0940 19/.1055 37/.0822 37/.0900 37/.0972 37/.1040 37/.1159 61/.0992 61/.1109 61/.1280

0.134 0.169 0.213 0.268 0.299 0.336 0.376 0.423 0.475 0.520 0.570 0.616 0.659 0.736 0.813 0.908 1.060

0.085 0.085 0.085 0.085 0.105 0.105 0.105 0.105 0.105 0.120 0.120 0.120 0.120 0.120 0.135 0.135 0.135

0.62 0.69 0.78 0.89 1.03 1.10 1.18 1.28 1.38 1.53 1.63 1.72 1.81 1.96 2.18 2.37 2.67

32 50 78 126 158 198 250 316 398 524 564 658 752 942 1130 1412 1828

104 134 180 244 324 382 450 534 638 826 890 1006 1122 1350 1636 1970 2470

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

234 20170107

LOW VOLTAGE CABLES

Construction Conductor: 8 AWG thru 1000 kcmil compact aluminum ACM (8000 series) conductors. Insulation is Flame-Retardant Cross-Linked Polyethylene (XLPE), black, suitable for 2000 V. Print Legend: AWG (PLANT OF MFG) SUNGUARD™ 2000 V PV WIRE OR RHH OR RHW-2 OR 600 V USE-2 (SIZE) AL ACM 90°C WET OR DRY SUN RES (UL) -40 ºC c(UL) RWU90 1000 V DIR BUR MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE MARK Duplexing: One phase conductor is black, the other conductor is black with three white stripes. Conductors are pre-twisted together on reel.

Features • Rated 90ºC wet and dry • Deformation-resistant at high temperatures • Excellent moisture resistance, exceeds UL 44 • Stable electrical properties over a broad temperature range • Excellent resistance to crush and compression cuts • Resistant to most oils and chemicals • UV/sunlight-resistant • Meets cold bend test at -40ºC • Use Duplex SunGard to avoid mismatch of Positive and Negative sets • Reduce labor costs and equipment cost for laying cable in trench by deploying one reel, instead of two

LOW VOLAGE CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

SunGuard™ Paralleled Aluminum XLPE UL Type PV Photovoltaic Wire 2kV Applications Paralleled conductors are sunlight-resistant, photovoltaic wire rated 90°C wet or dry, 2000 volts for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70. • For use in free air, raceways or direct burial in accordance with NEC.

Features • Rated 90°C wet and dry • Deformation-resistant at high temperatures • Excellent moisture resistance, exceeds UL 44

Item #

Conductor Size (AWG/kcmil)

A802PV2X0700* A602PV2X0700* A402PV2X0700* A202PV2X0700* A102PV2X1900* A1/002PV2X190* A2/002PV2X1900* A3/002PV2X1900* A4/002PV2X1900* A25002PV2X3700* A30002PV2X3700* A35002PV2X3700* A40002PV2X3700* A50002PV2X3700* A60002PV2X6100* A75002PV2X6100* A100002PV2X6100*

8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 1000

Standards • Rated 90°C wet and dry • Deformation-resistant at high temperatures • Excellent moisture resistance, exceeds UL 44 • Stable electrical properties over a broad temperature range • Excellent resistance to crush and compression cuts • Resistant to most oils and chemicals • UV/sunlight-resistant • Meets cold bend test at 40°C • VW-1 Rating upon available upon request Note Material cut to length and shipped on non-returnable wood or steel reels Option UL 1581 VW-1 compliance available on request

Conductor Stranding

Nominal Conductor O.D. (in)

Minimum Average Insulation Thickness (in)

Duplexed Cable Diameter (in)

Aluminum Weight (lbs/MFT)

Net Cable Weight (lbs/MFT)

7/.0486 7/.0612 7/.0772 7/.0974 19/.0664 19/.0745 19/.0837 19/.0940 19/.1055 37/.0822 37/.0900 37/.0972 37/.1040 37/.1159 61/.0992 61/.1109 61/.1280

0.134 0.169 0.213 0.268 0.299 0.336 0.376 0.423 0.475 0.520 0.570 0.616 0.659 0.736 0.813 0.908 1.060

0.085 0.085 0.085 0.085 0.105 0.105 0.105 0.105 0.105 0.120 0.120 0.120 0.120 0.120 0.135 0.135 0.135

.62 .69 .78 .89 1.03 1.10 1.08 1.28 1.38 1.53 1.63 1.72 1.81 1.96 2.18 2.37 2.67

32 50 78 126 158 198 250 316 398 524 564 658 752 942 1130 1412 1828

104 134 180 244 324 382 450 534 638 826 890 1006 1122 1350 1636 1970 2470

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

243 20180201

LOW VOLTAGE CABLES

Construction Conductor: 8 AWG thru 1000 kcmil compact aluminum ACM (8000 series) conductors. Insulation is Flame-Retardant Cross-Linked Polyethylene (XLPE), black, suitable for 2000 V. Print Legend: AWG (PLANT OF MFG) SUNGUARD™ 2000 V PV WIRE OR RHH OR RHW-2 OR 600 V USE-2 (SIZE) AL ACM 90°C WET OR DRY SUN RES (UL) 40°C c(UL) VW-1 RWU90 1000 V DIR BUR MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE MARK Paralleling: One phase conductor is black with red stripes, the other conductor is white with red stripes. Conductors are preinstalled together on reel.

• Stable electrical properties over a broad temperature range • Excellent resistance to crush and compression cuts • Resistant to most oils and chemicals • UV/sunlight-resistant • Meets cold bend test at 40°C • Use Parallel SunGard to avoid mismatch of Positive and Negative sets • Reduce labor costs and equipment cost for laying cable in trench by deploying one reel, instead of two

LOW VOLAGE CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 20X 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Copper PVC UL THW-2 75°C 600V Application Single conductor general purpose wiring for lighting and power. The product is insulated with polyvinylchloride (PVC), and dual rated as UL Types TW and THW. It is intended for use in accordance with the NEC in residential, commercial and industrial applications not exceeding 600V and/or 75°C in wet or dry locations. Construction • Single conductor copper insulated with polyvinylchloride (PVC), solid or stranded, tinned or bare soft annealed copper per ASTM B-3, B-8 and complying with the physical and electrical requirements of UL standards 83 and 1851. • Identified by surface marking indicating manufacturers identification, conductor size, voltage rating, and UL Type TW and THW designations.

Item #

THW-C14S THW-C12S THW-C10S THW-C14 THW-C12 THW-C10 THW-C8 THW-C6 THW-C4 THW-C3 THW-C2 THW-C1 THW-C1/0 THW-C2/0 THW-C3/0 THW-C4/0 THW-C250 THW-C300 THW-C350 THW-C400 THW-C500

Size AWG or MCM

Number of Strands

Insulation Thickness (mil)

Approximate O.D. (in)

Amapcity 3/C in Raceway

Shipping Weight /MFT (lb)

14 12 10 14 12 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500

Solid Solid Solid 7 7 7 7 7 7 7 7 19 19 19 19 19 37 37 37 37 37

45 45 45 45 45 45 60 60 60 60 60 80 80 80 80 80 95 95 95 95 95

0.16 0.18 0.20 0.17 0.19 0.21 0.20 0.31 0.36 0.39 0.42 0.49 0.53 0.58 0.63 0.69 0.77 0.82 0.87 0.95 1.01

15 20 30 15 20 30 50 65 85 100 115 130 150 175 200 230 255 285 310 335 380

22 31 45 24 33 48 77 112 167 202 252 324 397 491 608 753 896 1060 1227 1391 1715

LOW VOLTAGE CABLES

Standards • Underwriters Lab standard 83 for thermoplastic insulated wires. • Underwriters Lab standard 1581 for wires, cables, and cords. • ICEA S-95-658/NEMA WC70 • Federal Specification JC-30B

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

219 20140110

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Copper PVC UL TFFN/TFN 90°C 600V Applications For internal wiring of fixtures, fixture raceways, fire alarm circuits in raceways. Construction • Conductor is fully Annealed bare copper per ASTM B-3 and B-174. • Insulation is color coded premium grade flame retardant PVC (polyvinyl chloride). • Jacket is tough polyamide nylon. • VW-1 Flame Test rated. • Gasoline and Oil Resistant II • Resistant to abrasion, acids, alkalines, ozone and water.

Item #

TFFN-C18 TFFN-C16 TFN-C18S TFN-C16S

Conductor Size AWG

Number of Strands

Approx. O.D. (in)

Insulation Thickness (mil)

Jacket Thickness (mil)

Shipping Weight /MFT (lb)

18 16 18 16

16 26 Solid Solid

0.088 0.101 0.088 0.101

15 15 15 15

4 4 4 4

8 12 8 12

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

226 20140921

LOW VOLTAGE CABLES

Standards • ASTM B-3 and B-174. • UL Standard 62 for fixture wire. • UL Standard 1063 for machine tool wire • NY State DOS 16120-880926-2008 • OSHA acceptable • NFPA 70 (NECR) • NFPA 79 AWM 600V 105°C (75°C in oil).

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Copper PVC/Nylon UL THHN/THWN-2 90°C Dry or 75°C Wet 600V Application General purpose building wire for services, feeders and branch circuits. Suitable for use in conduit and raceways; 1/0 and larger for cable tray use. Construction • Conductor is bare annealed copper per ASTM B-3. • Stranded conductors per ASTM B-8. • Insulation is color coded premium grade flame retardant PVC (polyvinyl chloride). • Jacket is tough polyamide nylon. • VW-1 AWG rated through 4/0 AWG. • 1/0 AWG and larger rated for CT use. • 1/0 AWG and larger rated Sunlight Resistant. • Gasoline and Oil Resistant II. • Resistant to abrasion, acids, alkalines, ozone, and water.

Item #

THHN-C14S THHN-C12S THHN-C10S THHN-C14 THHN-C12 THHN-C10 THHN-C8 THHN-C6 THHN-C4 THHN-C3 THHN-C2 THHN-C1 THHN-C1/0 THHN-C2/0 THHN-C3/0 THHN-C4/0 THHN-C250 THHN-C300 THHN-C350 THHN-C400 THHN-C500 THHN-C600 THHN-C750 THHN-C1000

LOW VOLTAGE CABLES

Standards • ASTM B-3 and B-8 • UL Standard 83 — THHN/THWN-2 • UL Standard 1581 for machine tool wire • ICEA S-95-658/NEMA WC70 • Federal Specification JC-30B • OSHA acceptable • NFPA 70 (NECR) • NFPA 79 AWM 600V 105°C (75°C in oil).

Size AWG or MCM

Number of Strands

Insulation Thickness (mil)

Nylon Jacket Thickness (mil)

Approximate O.D. (in)

Amapcity 75°C Wet

Ampacity 90°C Dry

Shipping Weight /MFT (lb)

14 12 10 14 12 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 1000

Solid Solid Solid 19 19 19 19 19 19 19 19 19 19 19 19 19 37 37 37 37 37 61 61 61

15 15 20 15 15 20 30 30 40 40 40 50 50 50 50 50 50 60 60 60 60 70 70 70

4 4 4 4 4 4 5 5 6 6 6 7 7 7 7 7 7 8 8 8 8 9 9 9

0.102 0.118 0.150 0.110 0.128 0.161 0.212 0.250 0.318 0.345 0.375 0.430 0.470 0.515 0.565 0.620 0.730 0.780 0.830 0.880 0.970 1.060 1.170 1.300

20 25 30 20 25 35 50 65 85 100 115 130 150 175 200 230 255 285 310 335 380 420 475 545

25 30 40 25 30 35 55 75 95 105 130 150 170 195 225 260 290 320 350 380 430 475 535 615

17 25 39 18 27 40 69 109 166 202 254 316 398 488 603 731 903 1058 1211 1332 1735 1990 2428 3263

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

218 20140925

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

UF-B Copper Underground Feeder 600V 75°C Applications For direct burial, for use in dwellings not exceeding 3 floors above grade, as underground feeder to outdoor lighting or apparatus, or as general branch circuit wiring. Recognized for use as exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations. For use as new wiring or as replacement wiring. Construction • Conductor is bare annealed copper per ASTM B-3 or stranded conductors, per ASTM B-8. • Insulation is color coded PVC (polyvinyl chloride) with a nylon jacket. • Type THHN inners, rated 90°C. • Ampacity is limited to that for 60°C conductors per NECR Articles 336 and 339. • Jacket is gray PVC (polyvinyl chloride). • Color code — 2 conductor: black, white; 3 conductor: black, white, red.

Item #

UFB-1 UFB-2 UFB-3 UFB-4 UFB-5 UFB-6 UFB-7 UFB-8 UFB-9 UFB-10 UFB-11 UFB-12 UFB-13 UFB-14 UFB-15 UFB-16 UFB-17 UFB-18

Constr./ Size AWG

Number of Strands

Ground Wire Size

Approximate O.D. (in)

Shipping Weight /MFT (lb)

14/2 12/2 10/2 14/3 12/3 10/3 8/3 6/3 14/2 12/2 10/2 8/2 6/2 14/3 12/3 10/3 8/3 6/3

Solid Solid Solid Solid Solid Solid 7 7 Solid Solid Solid 7 7 Solid Solid Solid 7 7

(None) (None) (None) (None) (None) (None) (None) (None) 14 12 10 10 10 14 12 10 10 10

.20 x .39 .21 x .42 .23 x .46 .20 x .57 .21 x .62 .23 x .68 .34 x .96 .40 x 1.20 .21 x .40 .22 x .43 .24 x .47 .32 x .62 .41 x .81 .20 x .57 .21 x .62 .23 x .68 .34 x .96 .40 x 1.20

60 79 107 97 130 173 284 467 79 107 148 246 358 111 151 207 317 501

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

220 20140110

LOW VOLTAGE CABLES

Standards • Listed under UL Standard 493. • Federal Specification JC-30B. • ASTM B-3 and B-8

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Copper XLP UL XHHW-2 600V 90°C Wet or Dry Applications Single conductor crosslinked polyethylene (XLP or XLPE) Type XHHW-2, intended for use at 600 volts or less. It is approved for general purpose lighting and power applications at a maximum continuous operating temperature of 90°C in wet or dry locations. VW-1 available where required. Construction Single copper conductors, solid or stranded annealed or hard uncoated copper per UL83 and ASTM requirements. Insulates with XLP as specified and applied tightly to the conductor in a concentric manner. The mimimum at any point shall not be less than 90% of the specified average thickness in compliance with UL 44. Identified by surface marking indicating the manufacturer, conductor size, voltage rating, UL symbol, and type designation. Continuously spark tested at 7500 Volts DC and pass the 4 hour cold bend test of -25°C. Other electrical and mechanical tests shall be in accordance with UL 44 and UL 1581.

Item #

XHHW-C14 XHHW-C12 XHHW-C10 XHHW-C8 XHHW-C6 XHHW-C4 XHHW-C3 XHHW-C2 XHHW-C1 XHHW-C1/0 XHHW-C2/0 XHHW-C3/0 XHHW-C4/0 XHHW-C250 XHHW-C300 XHHW-C350 XHHW-C400 XHHW-C500 XHHW-C600 XHHW-C750 XHHW-C1000

LOW VOLTAGE CABLES

Standards • Underwriter’s Laboratories UL 44 • Canadian Standard C22.2 No. 38 • Insulated Cable Engineers Association ICEA S-95-658 • Institute of Electrical and Electronics Engineers IEEE 1202 • Federal Specification A-A-59544 • NEMA Publication No. WC-70 • Gas and Oil Resistant II (UL)

Size AWG or MCM

Number of Strands

Insulation Thickness (mil)

Approximate O.D. (in)

Copper Weight /MFT (lb)

Shipping Weight /MFT (lb)

Ampacity 90°C Dry

14 12 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 1000

7/19 7/19 7/19 7 7 7 7 7 19 19 19 19 19 37 37 37 37 37 61 61 61

30 30 30 45 45 45 45 45 55 55 55 55 55 65 65 65 65 65 80 80 80

0.140 0.160 0.180 0.240 0.280 0.330 0.349 0.390 0.450 0.490 0.535 0.590 0.645 0.715 0.770 0.820 0.870 0.955 1.040 1.150 1.300

12.7 20.2 32.1 51.0 81.1 128.9 162.5 204.9 258.4 325.8 410.9 518.1 653.3 771.9 926.3 1081.0 1235.0 1544.0 1853.0 2316.0 3008.0

18 27 41 67 100 153 190 236 292 363 452 562 702 831 1000 1160 1322 1643 1982 2461 3257

15 20 30 55 75 95 110 130 150 170 195 225 260 290 320 350 N/A 430 475 535 615

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

222 20140921

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Copper XLP Type SIS VW-1 90°C 600V Applications Single conductor cross-linked polyethylene (XLP or XLPE) Type SIS-VW-1 for use at 600V or less. Approved per NEC Article 384 for instrument and control wiring where wiring is required to pass the UL vertical flame test. Rated for a maximum continuous operating temperature of 90°C in wet or dry locations.

Standards • Tin-coated, soft annealed copper per ASTM B-33, Class B stranding ASTM B-8 • ICEA S-95-658/NEMA WC-70 • UL 44 for Thermoset Insulated Wires & Cables • Fed Spec J-C-30B

Item #

SIS-1-18 SIS-2-16 SIS-3-14 SIS-4-12 SIS-5-10 SIS-6-8 SIS-7-6 SIS-8-4 SIS-9-2 SIS-10-1 SIS-11-1/0

Size AWG

Number of Strands

Optional Stranding

Insulation Thickness (mil)

Nominal Overall Diameter (in)

Shipping Weight /MFT (lb)

18 16 14 12 10 8 6 4 2 1 1/0

16 26 41 65 105 133 133 133 133 133 133

7, 19 7, 19 7, 19 7, 19 7, 19 7, 19 7, 19 7, 19 7, 19 19, 37 19, 37

30 30 30 30 30 45 45 45 45 55 55

.09 / .10 .11 / .12 0.13 / 0.14 0.15 / 0.16 0.17 / 0.18 0.24 / 0.25 0.28 / 0.30 0.32 / 0.34 0.38 / 0.40 0.44 / 0.48 0.48 / 0.52

11 15 21 27 40 75 115 175 250 330 400

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

221 20140921

LOW VOLTAGE CABLES

Construction • Stranded conductor, annealed, coated copper per UL83 and ASTM requirements. • Insulated with XLP as specified and applied tightly to the conductor in a concentric manner. • Conductors are “Oil and Gas Resistant II.” • The standard color is gray; other colors available. • All black insulation is rated “Sunlight Resistant.” • The minimum at any point shall not be less than 90% of the specified average thickness in compliance with UL 44. • Identified by surface marking indicating manufacturers identification, conductor size, voltage rating, and UL symbol, VW-1, and type designation. • Continuously spark tested at 7500V DC and pass the 4 hour cold bend test at -25°C. Other electrical and mechanical tests shall be in accordance with UL 44 and UL 1581.

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Copper XLP UL RHH/RHW-2 or USE-2 90°C 600V Applications Single conductor cross-linked polyethylene (XLP or XLPE) Type RHW-2 and USE-2 for use at 600V or less. It is approved per the NEC for general purpose lighting and power applications at a maximum continuous operating temperature of 90°C in wet and dry locations. Suitable for direct burial. Construction The single copper conductors shall be solid or stranded annealed or hard uncoated copper per UL83 and ASTM requirements. Insulated with XLP as specified and applied tightly to the conductor in a concentric manner. All black insulation is rated “Sunlight Resistant.” The minimum at any point shall not be less than 90% of the specified average thickness in compliance with UL 44. The wire shall be identified by surface marking indicating the manufacturer, conductor size, voltage rating, UL symbol, and type designation. The wire shall be continuously spark tested at 7500V DC. Other electrical and mechanical tests shall be in accordance with UL44, UL 854 and UL 1581.

Item #

USE2-C14 USE2-C12 USE2-C10 USE2-C8 USE2-C6 USE2-C4 USE2-C3 USE2-C2 USE2-C1 USE2-C1/0 USE2-C2/0 USE2-C3/0 USE2-C4/0 USE2-C250 USE2-C300 USE2-C350 USE2-C400 USE2-C500 USE2-C600 USE2-C750 USE2-C1000

Size AWG or MCM

Number of Strands

Insulation Thickness (mil)

Approximate O.D. (in)

Copper Weight /MFT (lb)

Shipping Weight /MFT (lb)

Ampacity 90°C Dry

14 12 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 1000

7 7 7 7 7 7 7 7 19 19 19 19 19 37 37 37 37 37 61 61 61

45 45 45 60 60 60 60 60 80 80 80 80 80 95 95 95 95 95 110 110 110

0.16 0.17 0.20 0.27 0.31 0.37 0.39 0.43 0.51 0.56 0.60 0.66 0.72 0.80 0.86 0.91 0.94 1.05 1.16 1.27 1.44

12.7 20.2 32.1 51.0 81.1 128.9 162.5 204.9 258.4 325.8 410.9 518.1 653.3 771.9 926.3 1081.0 1235.0 1544.0 1853.0 2316.0 3008.0

22 31 45 74 108 161 198 244 319 392 484 599 743 889 1053 1217 1379 1703 2056 2540 3343

15 20 30 55 75 95 110 130 150 170 195 225 260 290 320 350 380 430 475 535 615

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

223 20140110

LOW VOLTAGE CABLES

Standards • ASTM B-1, B-3 and B-8 for copper conductors • ICEA S-95-658/NEMA WC70 • UL 854 for Service Entrance Cables (incl. Para. 854-38.7 for 300 hr. sunlight resistance) and UL 44 for Thermoset Insulated Wires & Cables • Fed Spec J-C-30B

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

SunGuard™ Copper XLPE UL Type PV Photovoltaic Wire UL Type PV/RHH or RHW-2 600V or 600V USE-2 Applications For use in grounded and ungrounded Photovoltaic power systems Construction • Stranded bare and tinned copper conductors per ASTM B-3, B-8. • Chemically Cross-linked Polyethylene insulation. • Available Colors: Black, Green, White, Red. • Print on one side with a contrasting ink. An extruded stripe and other colors are available upon request.

Industry Listings & Standards Industry Compliances • UL 4703 Type PV • National Electrical Code (NEC) • ICEA S-95-658/NEMA WC70 • UL 44 Type RHH or RHW-2 • UL 854 Type USE-2 for 600 V • c(UL) RWU90 1 kV (-40C) Other Compliances • EPA 40 CFR, Part 261 for leachable lead content per TCLP • OSHA Acceptable • RoHS Compliant

Packaging Material cut to length and shipped on non-returnable wood reels

Item #

AWG

Stranding

PV-600-18 PV-600-16 PV-600-14 PV-600-12 PV-600-10 PV-600-08 PV-600-06 PV-600-04 PV-600-02 PV-600-01 PV-600-1/0 PV-600-2/0 PV-600-3/0 PV-600-4/0 PV-600-250 PV-600-300 PV-600-350 PV-600-400 PV-600-500 PV-600-600 PV-600-750 PV-600-1000

18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 1000

7 7 7 7 7 7 7 7 7 19 19 19 19 19 37 37 37 37 37 61 61 61

Nominal Nominal Minimum Minimum Conductor Conductor Average Average O.D. O.D. Insulation Insulation (in) (mm) (in) (mm) 0.045 0.056 0.070 0.088 0.112 0.143 0.184 0.234 0.296 0.323 0.370 0.410 0.460 0.520 0.558 0.611 0.661 0.706 0.789 0.866 0.968 1.117

1.14 1.42 1.78 2.23 2.84 3.63 4.67 5.94 7.52 8.20 9.40 10.41 11.68 13.21 14.17 15.52 16.79 17.93 20.04 22.00 24.59 28.37

0.060 0.060 0.060 0.060 0.060 0.080 0.080 0.080 0.080 0.095 0.095 0.095 0.095 0.095 0.110 0.110 0.110 0.110 0.110 0.125 0.125 0.125

1.52 1.52 1.52 1.52 1.52 2.03 2.03 2.03 2.03 2.41 2.41 2.41 2.41 2.41 2.79 2.79 2.79 2.79 2.79 3.18 3.18 3.18

Nominal Cable Diameter (in)

Nominal Cable Diameter (mm)

Copper Weight (lb/MFT)

Copper Weight (kg/km)

Net Weight (lb/MFT)

Net Weight (kg/km)

0.169 0.180 0.194 0.214 0.238 0.307 0.348 0.398 0.460 0.515 0.563 0.608 0.658 0.714 0.784 0.837 0.887 0.932 1.015 1.122 1.224 1.373

4.29 4.57 4.93 5.43 6.04 7.80 8.84 10.11 11.68 13.08 14.30 15.44 16.71 18.13 19.91 21.26 22.53 23.67 25.78 28.50 31.09 34.87

5 8 13 20 32 50 81 129 205 258 326 411 518 653 772 926 1063 1235 1509 1883 2316 3088

7 12 19 30 48 74 121 192 305 384 485 611 771 972 1149 1378 1582 1838 2246 2802 3447 4595

14 18 27 36 51 85 123 180 267 333 410 502 620 767 923 1090 1240 1423 1718 2136 2597 3411

21 27 40 54 76 126 183 268 397 495 610 747 922 1141 1374 1622 1845 2117 2557 3179 3865 5076

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

203 20180201

LOW VOLTAGE CABLES

Option UL 1581 VW-1 compliance available on request 19 strand conductors available on request

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Copper EPR/CPE RHH/RHW-2 or USE-2 90°C 600V Applications Recommended for use in all low voltage circuits where continuity of service is the prime consideration. These cables may be installed in wet or dry locations, indoors or outdoors, in raceways, underground ducts, directly buried in the earth, or lashed to a messenger for aerial installation. These cables may also be installed in cable tray (size 1/0 AWG and larger per NEC 392.2). Specifications Conductor: Uncoated copper solid per ASTM-B-3, compress stranded per ASTM B-8, or compact per ASTM B-496. Insulation: Meets or exceeds all requirements of ICEA S-95-658/NEMA WC-70 and UL Standards 44 and 854. Jacket: CSPE. Listed by Underwriters Laboratories, Inc. as Type RHH or RHW-2 or USE-2, VW-1. Sizes 1/0 AWG and larger are also marked “sunlight resistant, for use in cable tray.” Listed by CSA as RW-90, -25C, FT1 (1/0 and larger FT4), outdoor.

Notes These ampacities are based on single conductor in free air, 40°C ambient air temperature, 90°C conductor operating temperature. Options PVC or LSOH jacket

Item #

Conductor Size AWG or MCM

USE2-14 14 AWG USE2-12 12 AWG USE2-10 10AWG USE2-8 8 AWG USE2-6 6 AWG USE2-4 4 AWG USE2-2 2 AWG USE2-1/0 1/0 AWG USE2-2/0 2/0 AWG USE2-4/0 4/0 AWG USE2-250 250 MCM USE2-350 350 MCM USE2-500 500 MCM USE2-750 750 MCM USE2-1000 1000MCM

Conductor Conductor Nominal Stranding Diameter Insulation (in) (in) 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61

0.072 0.091 0.116 0.146 0.183 0.231 0.292 0.373 0.419 0.528 0.575 0.681 0.813 0.980 1.152

0.030 0.030 0.030 0.045 0.045 0.045 0.045 0.055 0.055 0.055 0.065 0.065 0.065 0.080 0.080

Min. (in)

Nominal Jacket Thickness Min. Approx. Approx. Max. Max. (mm) (in) (mm) (in) (mm)

0.161 0.185 0.205 0.268 0.335 0.382 0.441 0.559 0.602 0.717 0.827 0.929 1.055 1.264 1.413

4.10 4.70 5.20 6.80 8.50 9.70 11.20 14.20 15.30 18.20 21.00 23.60 26.80 32.10 35.90

0.165 0.189 0.213 0.276 0.346 0.394 0.453 0.575 0.619 0.736 0.850 0.957 1.088 1.303 1.457

4.20 4.80 5.40 7.00 8.80 10.0 11.50 14.60 15.73 18.70 21.60 24.30 27.64 33.10 37.0

0.177 0.205 0.228 0.299 0.374 0.425 0.488 0.622 0.669 0.795 0.917 1.031 1.177 1.406 1.575

4.50 5.20 5.80 7.60 9.50 10.80 12.40 15.80 17.00 20.20 23.30 26.20 29.90 35.70 40.00

Nominal O.D. (in)

Approx. Weight /MFT (lb)

Ampacity 40°C Ambient Temp.

0.236 0.256 0.290 0.333 0.403 0.461 0.510 0.700 0.740 0.870 0.990 1.055 1.125 1.205 1.305

24 34 49 79 124 179 260 420 513 774 956 1290 1798 2686 3463

25 32 47 83 109 145 192 258 298 400 445 552 695 898 1076

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

224 20140110

LOW VOLTAGE CABLES

Product Features • Sizes 1/0 AWG and larger pass the Vertical Tray Flame Test requirements of UL 1581 for use in cable tray. • Passes the IEEE 383-1974 Vertical Tray Flame Test. • Passes the IEEE 1202-1991 Vertical Tray Flame Test. (sizes 1/0 AWG & larger). • Extreme heat resistance; 90°C continuous rating, wet or dry 110°C hot spot rating 130°C emergency overload rating 250°C short circuit rating

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Copper XLP UL RHH/RHW-2 or USE-2 90°C 2kV Application Type RHH, RHW-2 is suitable for wiring in raceways, conduit, etc. Applications include general purpose wiring for power distribution, services, feeders, and branch circuit wiring in residential, industrial, and commercial buildings. • For use in free air, raceways or direct burial in accordance with NEC.

Item #

14-01XLP2000 12-01XLP2000 10-01XLP2000 8-01XLP2000 6-01XLP2000 4-01XLP2000 3-01XLP2000 2-01XLP2000 1-01XLP2000 1/0-01XLP2000 2/0-01XLP2000 3/0-01XLP2000 4/0-01XLP2000 250-01XLP2000 300-01XLP2000 350-01XLP2000 400-01XLP2000 500-01XLP2000 600-01XLP2000 750-01XLP2000

Stranding

Size AWG or KCMIL

Insulation Thickness (mil)

Nominal Overall Diameter (in)

Approximate Net Weight (lb/MFT)

Ampacity* 90°C Wet/Dry

7 7 7 7 7 7 7 7 19 19 19 19 19 37 37 37 37 37 61 61

14 12 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750

60 60 60 80 80 80 80 80 95 95 95 95 95 110 110 110 110 110 125 125

0.193 0.212 0.236 0.306 0.344 0.392 0.420 0.452 0.511 0.550 0.594 0.644 0.700 0.795 0.849 0.901 0.948 1.033 1.143 1.248

27 37 51 83 120 175 212 259 330 404 497 613 758 909 1,074 1,239 1,402 1,728 2,084 2,571

35† 40† 55† 80 105 140 165 190 220 260 300 350 405 455 500 570 615 700 780 885

*Based on ambient temperature of 30°C per NEC-Table 310-17 †The overcurrent protection for items marked with an obelisk (†) shall not exceed 15 amps for #14 AWG, 20 amps for #12 AWG, and 30 amps for #10 AWG per NEC 310-17 footnote. Data shown is approximate and subject to standard industry tolerances.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

233 20151123

LOW VOLTAGE CABLES

Construction Conductor: Single copper conductor, stranded Insulation: Heat resistant cross-linked polyethylene. Temperature rating is 90°C in wet and dry applications Packaging: All produced or cut-to-order material will be shipped on non-returnable wooden reels unless specifically requested.

Standards • ASTM B3, B8 and B787 • UL 44 ICEA S-95-658/NEMA WC-70 • For CT use 1/0 AWG and larger • Gasoline and Oil Resistant II • -40°C rated to 90°C in wet and dry applications • C(UL) US RWU90 1kV:CSA/UL Listed • C(UL) RPVU90 1kV • Sunlight Resistant • RoHS Compliant

LOW VOLAGE CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

DLO Copper EPR/CPE UL RHH/RHW-2 2kV Applications This cable is for wiring down tower applications and may be used on electrically driven, earth moving equipment, as power supply to A.C. welding equipment, as water heater leads, and in motor and power lead applications. May be installed in wet or dry areas, conduit, ducts, trays or troughs. Construction • Conductor is extra flexible tinned, stranded copper with a separator layer. • EPR insulation. • Jacket is CPE (Hypalon jacket available upon request). Standards • Meets flame test requirements of MSHA and passes ICEA cold bend test at -40°C. • Meets AAR specifications. • UL listed as RHH-RHW-2. • Rated for CT use, 1/0 and larger.

Item #

Area Circular (mil)

Size AWG

Number of Strands in Conductor

Insulation Thickness (in)

Jacket Thickness (mil)

Overall Diameter (in)

Net Weight /MFT (lb)

Ampacity 1/C Free Air 90°C

DL-600/2-1 DL-600/2-2 DL-600/2-3 DL-600/2-4 DL-600/2-5 DL-600/2-6 DL-600/2-7 DL-600/2-8 DL-600/2-9 DL-600/2-10 DL-600/2-11 DL-600/2-12 DL-600/2-13 DL-600/2-14 DL-600/2-15 DL-600/2-16 DL-600/2-17 DL-600/2-18 DL-600/2-19 DL-600/2-20 DL-600/2-21 DL-600/2-22

3831 6088 10910 14950 24640 36760 42420 60600 90900 111100 131300 181800 222200 262600 313100 373700 444400 535300 646400 777700 929200 1111000

14 12 10 8 6 5 4 2 1 1/0 2/0 3/0 4/0 262.6 313.1 373.7 444.4 535.3 646.4 777.7 929.2 1111.0

19 19 27 37 61 91 105 150 225 275 325 450 550 650 775 925 1100 1325 1591 1924 2299 2745

.045 .045 .045 .060 .060 .060 .060 .060 .080 .080 .080 .080 .080 .090 .090 .090 .090 .110 .110 .110 .110 .110

30 30 30 30 30 30 30 30 45 45 45 45 45 65 65 65 65 65 65 65 65 65

.24 .25 .29 .33 .40 .43 .45 .50 .64 .69 .73 .80 .86 .97 1.01 1.11 1.18 1.29 1.38 1.47 1.58 1.74

34 45 68 82 125 175 195 265 425 500 570 780 890 1100 1280 1500 1760 2110 2410 2930 3450 4130

32 36 55 83 109 127 145 192 223 258 298 345 400 458 514 574 642 725 815 910 1025 1143

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

709 20140921

LOW VOLTAGE CABLES

Notes • Ampacity based on single conductor in free air, 90°C conductor temperature, 40°C ambient per ICEAS-75-381. • Sequential footage marks. • Shipping tolerance +/- 10%

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

SunGuard™ Copper XLPE UL Type PV Photovoltaic Wire Type PV/RHH 2kV or 600kV USE-2 Applications Appropriate for use in solar power applications that require 1000 or 2000 volt rating. For use in grounded and ungrounded Photovoltaic power systems. • For use in free air, raceways or direct burial in accordance with NEC.

Other Compliances • EPA 40 CFR, Part 261 for leachable lead content per TCLP • OSHA Acceptable • RoHS Compliant Option UL 1581 VW-1 compliance available on request 19 strand conductors available on request Packaging Material cut to length and shipped on non-returnable wood reels

Item #

AWG

Stranding

PV-2000-18 PV-2000-16 PV-2000-14 PV-2000-12 PV-2000-10 PV-2000-08 PV-2000-06 PV-2000-04 PV-2000-02 PV-2000-01 PV-2000-1/0 PV-2000-2/0 PV-2000-3/0 PV-2000-4/0 PV-2000-250 PV-2000-300 PV-2000-350 PV-2000-400 PV-2000-500 PV-2000-600 PV-2000-750 PV-2000-1000

18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 1000

7 7 7 7 7 7 7 7 7 19 19 19 19 19 37 37 37 37 37 61 61 61

Nominal Nominal Minimum Minimum Conductor Conductor Average Average O.D. O.D. Insulation Insulation (in) (mm) (in) (mm) 0.045 0.056 0.070 0.088 0.112 0.143 0.184 0.234 0.296 0.323 0.370 0.410 0.460 0.520 0.558 0.611 0.661 0.706 0.789 0.866 0.968 1.117

1.14 1.42 1.78 2.23 2.84 3.63 4.67 5.94 7.52 8.20 9.40 10.41 11.68 13.21 14.17 15.52 16.79 17.93 20.04 22.00 24.59 28.37

0.075 0.075 0.075 0.075 0.075 0.085 0.085 0.085 0.085 0.105 0.105 0.105 0.105 0.105 0.120 0.120 0.120 0.120 0.120 0.135 0.135 0.135

1.90 1.90 1.90 1.90 1.90 2.16 2.16 2.16 2.16 2.67 2.67 2.67 2.67 2.67 3.05 3.05 3.05 3.05 3.05 3.43 3.43 3.43

Nominal Cable Diameter (in)

Nominal Cable Diameter (mm)

Copper Weight (lb/MFT)

Copper Weight (kg/km)

Net Weight (lb/MFT)

Net Weight (kg/km)

0.199 0.210 0.224 0.244 0.268 0.326 0.363 0.406 0.474 0.538 0.586 0.631 0.674 0.737 0.804 0.857 0.907 0.952 1.035 1.142 1.244 1.393

5.05 5.33 5.69 6.20 6.81 8.28 9.22 10.31 12.04 13.66 14.88 16.03 17.12 18.72 20.42 21.77 23.04 24.18 26.29 29.01 31.60 35.38

5 8 13 20 32 50 81 129 205 258 326 411 518 653 772 926 1063 1235 1509 1883 2316 3088

7 12 19 30 48 74 121 192 305 384 485 611 771 972 1149 1378 1582 1838 2246 2802 3447 4595

16 21 32 42 57 87 123 181 266 350 429 527 647 796 938 1106 1257 1441 1737 2157 2620 3437

24 31 48 62 85 129 183 269 396 521 638 784 963 1184 1396 1646 187 2144 2585 3211 3900 5115

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

231 20180201

LOW VOLTAGE CABLES

Construction • Stranded bare and tinned copper conductors per ASTM B-3, B-8. • Chemically Cross-linked Polyethylene insulation. • Available Colors: Black, Green, White, Red. • Print on one side with a contrasting ink. An extruded stripe and other colors are available upon request.

Industry Listings & Standards Industry Compliances • UL 4703 Type PV • National Electrical Code (NEC) • ICEA S-95-658/NEMA WC70 • UL 44 Type RHH or RHW-2 • UL 854 Type USE-2 for 600 V • c(UL) RWU90 1 kV (-40C)

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

LSZH XLPO/LSZH XLPO Low-Voltage Power, Unshielded 600 V UL Type RHH/RHW-2/USE-2 Applications For use in closed environments or populated spaces such as auditoriums, arenas and health facilities where more stringent customer specifications for smoke and halogen-free materials are desired. Ideally suited for use in a broad range of commercial, industrial and utility applications where reliability is a major concern, where maximum performance will be demanded and where space is limited. For use in free air, raceways or direct burial in accordance with NEC.

Features • Rated at 90°C wet or dry • Low-Smoke, Zero-Halogen insulation system • Extra-tough, mechanically rugged composite insulation construction • Low friction for easy pulling on 8 AWG and larger • Excellent electrical, thermal and physical properties • Excellent moisture resistance, exceeding UL 44 requirements • Excellent resistance to crush, compression cuts and heat deformation • Excellent flame resistance

Item#

14-01XLSOH 12-01XLSOH 10-01XLSOH 8-01XLSOH 6-01XLSOH 4-01XLSOH 2-01XLSOH 1/0-01XLSOH 2/0-01XLSOH

Size AWG or KCMIL

Insulation Thickness (mil)

Nominal Conductor Diameter (in)

14 12 10 8 6 4 2 1/0 2/0

7/.0242 7/.0305 7/.0385 7/.0486 7/.0612 7/.0772 7/.0974 19/.0740 19/.0837

0.07 0.09 0.12 0.15 0.18 0.23 0.29 0.37 0.41

Minimum Average Insulation Thickness (in) 0.030 0.030 0.030 0.045 0.045 0.045 0.045 0.055 0.055

Minimum Average Insulation Diameter (in) 0.14 0.16 0.18 0.24 0.28 0.33 0.39 0.48 0.53

Compliances • National Electrical Code (NEC) • “FOR CT USE” on 1/0 AWG and larger in accordance with NEC • UL 44 Type RHH/RHW-2 • UL 854 Type USE-2 • Limited Smoke rating per UL 44 and UL 1685 • Compressed tinned copper per ASTM B33 • Class B stranding per ASTM B8 • ICEA T-33-655 smoke, halogen and acid gas requirements • ICEA S-95-658/NEMA WC70 Flame Test Compliances • For 1/0 AWG and larger: IEEE 383, IEEE 1202/CSA FT4 • UL 1685 Other Compliances • EPA 40 CFR, Part 261 for leachable lead content per TCLP • OSHA Acceptable • RoHS Compliant Packaging Material cut to length and shipped on non-returnable wood reels Options • 2 kV version • Bare copper conductor • Other stranding available

Minimum Average Jacket Thickness (in) 0.015 0.015 0.015 0.015 0.030 0.030 0.030 0.045 0.045

Minimum Average Jacket Diameter (in) 0.17 0.19 0.21 0.28 0.35 0.39 0.46 0.58 0.63

Copper Weight (lb/MFT)

Net Weight (lb/MFT)

13 20 32 50 81 129 205 326 411

24 33 48 77 122 178 265 422 518

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

241 20150108

LOW VOLTAGE CABLES

Construction Conductor: 14 AWG thru 1000 kcmil compressed tinned copper per ASTM B33, Class B stranding per ASTM B8 Insulation: Composite Low-Smoke, Zero-Halogen Cross-linked Polyolefin (LSZH XLPO) colored for contrast with black Low-Smoke, ZeroHalogen Cross-linked Polyolefin (LSZH XLPO) Print: AMERICAN WIRE GROUP LSZH TYPE USE-2 OR RHH OR RHW-2 (SIZE) 600 V OIL RES I SUN RES -40C ST1* FOR CT USE* (UL) DAY/MONTH/YEAR OF MFG SEQUENTIALFOOTAGE MARK* “ST1” and “FOR CT USE” on 1/0 AWG and larger.

• Resistant to most oils and chemicals • UV/sunlight-resistant • Rated ST-1 for Limited Smoke per UL 44 on sizes 1/0 AWG and larger • Stable electrical properties over a broad temperature range • Excellent low temperature cold bend characteristics, meets cold bend and cold impact test at -40°C

LSZH XLPO/LSZH XLPO Low-Voltage Power, Unshielded 600 V UL Type RHH/RHW-2/USE-2 Item#

Size AWG or KCMIL

Nominal Conductor Diameter (in)

19/.1055 37/.0822 37/.0973 37/.1162 61/.1109 61/.1280

0.52 0.56 0.67 0.80 0.97 1.13

Minimum Average Insulation Thickness (in) 0.055 0.065 0.065 0.065 0.080 0.080

Minimum Average Insulation Diameter (in) 0.64 0.70 0.81 0.94 1.15 1.31

Minimum Average Jacket Thickness (in) 0.045 0.065 0.065 0.065 0.065 0.065

Minimum Average Jacket Diameter (in) 0.74 0.85 0.96 1.09 1.31 1.46

Copper Weight (lb/MFT)

Net Weight (lb/MFT)

653 772 1081 1542 2316 3806

785 960 1299 1803 2664 3989

LOW VOLAGE CABLES

4/0-01XLSOH 4/0 250-01XLSOH 250 350-01XLSOH 350 500-01XLSOH 500 750-01XLSOH 750 1000-01XLSOH 1000

Insulation Thickness (mil)

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 241 20150108

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

SunGuard™ Tracker Motor Cable UL Type PV/TC 2kV

10-03XHPGTC2000

Specifications • Copper conductors conform to ASTM B-3 and B-8. • Insulated conductors RHH/RHW-2 Type per UL 44, USE-2 Type per UL 854, and PV Type per UL 4703, UL 1277 Type TC-ER • Cable is suitable for sunlight resistant and direct burial applications, and is approved For CT Use. • Cable meets the requirements of ICEA S-95658/NEMA WC70.

Construction Stranded copper conductors, XLP (Cross-Linked Polyethylene) insulation, Method 4 phase-identified; three insulated conductors cabled together with a stranded copper grounding conductor in one interstice, fillers as necessary, cable tape, black sunlight-resistant PVC (Polyvinyl Chloride) jacket overall, surface printed.

Notes • Dimensions are approximate and subject to normal manufacturing tolerances. • SHIPPING TOLERANCE +/- 10%

Size AWG

No. of Conductors

Ground Wire Size AWG

Insulation Thickness (mil)

Jacket Thickness (mil)

Nominal Conductor OD (in)

Approx. Weight (lb/MFT)

10

3

10

60

60

0.64

280

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

239 20170107

LOW VOLTAGE CABLES

Item #

Applications As three-conductor power cables rated 2000 volts, 90°C in dry or wet locations for Solar PV generation, this cable is connected to the tracker motors. Approved for installation in cable trays per Article 336 of the NEC. Type TC-ER cables are approved for use in Class 1, Division 2 hazardous locations. Cables may be installed in open air, in ducts or conduits, or in tray or trough. All cables when used in accordance with the NEC meet the requirements of OSHA.

LOW VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

MEDIUM VOLTAGE CABLES Table of Contents EPR Non-Shielded 2400V MV-90 ..........................................................................................301 L824 Type C Single Conductor, Non-Shielded XLPE 5000V Airport Lighting....................302 MV-105 Copper EPR Copper Tape Shield 5kV-133%/8kV-100% Insulation Level ...............303 MV-105 Copper EPR Copper Tape Shield 15kV 133% & 100% Insulation Levels...............304 MV-105 Copper EPR Copper Tape Shield 35kV 133% & 100% Insulation Level ................305 URD 175 Mil TRXLP 15kV 100% LLDPE Jacket AEIC CS-8...................................................306 URD 175 Mil EPR 15kV 100% LLDPE Jacket AEIC CS-8.......................................................307 URD 220 Mil TRXLP 15kV 133% LLDPE Jacket AEIC CS-8...................................................308 URD 220 Mil EPR 15kV 133% LLDPE Jacket AEIC CS-8.......................................................309 URD 260 Mil TRXLP 25kV 100% LLDPE Jacket AEIC CS-8 ...................................................310 URD 260 Mil EPR 25kV 100% LLDPE Jacket AEIC CS-8 .......................................................311 URD 345 Mil EPR 35kV 100% LLDPE Jacket AEIC CS-8.......................................................313 PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable LLDPE Jacket UL MV-90/AEIC CS8-07...............................................................................312 PowerGuard® 35kV 133% MV 420 Mil TR-XLPE AL Collection System Cable LLDPE Jacket UL MV- 90/AEIC CS8-07 - PHYSICAL PROPERTIES ..................................318

PowerGuard® 15kV 133% MV TR-XLPE Aluminum Collection System Cable XLPE Jacket UL MV-105/AEIC CS8-07 ...............................................................................320 PowerGuard® 5kV-35kV AluminumTR-XLPE Tape Shield PVC Jacket UL MV-105/AEIC CS8-07 .................................................................................314 PowerGuard® 5kV-35kV Copper 3-Conductor TR-XLPE Tape Shield w/Ground PVC Jacket UL MV-105/AEIC CS8-07 .................................................................................316 PowerGuard® 5kV-35kV Aluminum 3-Conductor TR-XLPE Tape Shield w/Ground PVC Jacket UL MV-105/AEIC CS8-07 .................................................................................317 PowerGuard® 15kV 133% Shielded Power Cable AL Conductor 220 mils EPR Copper Tape PVC Jacket MV-105................................................................................319 PowerGuard® Testing Recommendations............................................................................321

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

300 20170306

MEDIUM VOLTAGE CABLES

PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable XLPE Jacket UL MV-105/AEIC CS8-07 ...............................................................................315

MEDIUM VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Power Cable EPR Non-Shielded PVC Jacket 2400V MV-90 Application These cables comply with the exception notes of NEC Article 310.6 with respect to non-shielded cables above 2000V and the requirements of Table 310.63 for wet and dry locations. Consequently, where NEC requirements apply, this cable is suitable for use in wet and dry locations at a continuous conductor operating temperature of 90°C, at an emergency overload conductor temperature of 130°C and at a short circuit conductor temperature of 250°C. These cables may be installed in duct or conduit or properly supported aerial installations. Cables that are rated for use in cable tray applications are shown on the individual product specification sheets. Construction Conductors:The conductor is made up of uncoated soft, copper strands meeting the requirements of ASTM B3. Unless otherwise specified the conductors are supplied as Class B compact per ASTM B496. Insulation: The insulation is ethylene-propylene rubber (EPR) extruded concentrically over the conductor to the wall thickness as specified in the governing specifications listed and as shown on the individual product specification sheets. Jacket: A sunlight and ozone resistant jacket of polyvinylchloride (PVC) or chlorinated polyethylene (CPE) is extruded over the single and multi conductor assembly. Optional jacket materials are available that offer enhanced ratings and performance. Standards 1)Listed by UL as Type MV-90 per Standard 1072. 2)Conforms to ICEA S-96-659/N EMA WC71 Non-Shielded 2001 V - 5KV Cables. 3)Listed by UL For CT Use (Sizes #1/0 AWG and larger CPE jacketed).

Item #

Size AWG or KCM

2400-EPR-8 2400-EPR-6 2400-EPR-4 2400-EPR-2 2400-EPR-1 2400-EPR-1/0 2400-EPR-2/0 2400-EPR-3/0 2400-EPR-4/0 2400-EPR-250 2400-EPR-350 2400-EPR-500 2400-EPR-750 2400-EPR-1000

8* 6* 4* 2 1* 1/0 2/0 3/0 4/0 250 350 500 750 1000*

Number of Strands

Conductor Nominal O.D.

Insulation (mil)

Jacket (mil)

Approximate O.D. (in)

Ampacity** 40°C Ambient (lb)

Approximate Net Weight /MFT

0.14 0.18 0.23 0.27 0.32 0.34 0.38 0.42 0.48 0.52 0.62 0.74 0.91 1.12

125 125 125 125 125 125 125 125 125 140 140 140 155 155

80 80 80 80 80 80 80 95 95 110 110 110 125 125

0.62 0.64 0.69 0.75 0.78 0.81 0.86 0.94 0.99 1.11 1.21 1.33 1.58 1.79

55 75 97 130 155 180 205 240 280 315 385 475 600 690

215 260 330 430 500 585 685 815 1010 1190 1590 2120 3090 3950

(in) 7 7 7 7 19 19 19 19 19 37 37 37 61 61

*Compressed conductors. **Based on three single conductor cables in isolated conduit in air per NEC tolerances.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

301 20140917

MEDIUM VOLTAGE CABLES

Notes NEC 2005 no longer recognizes non-shielded 5000V construction and only recognizes 2400V nonshielded with the specific constructions attributes included in this specification. These cables meet the current relevant ICEA standards for 5000V non-shielded cables.

MEDIUM VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

L824 Type C Airport Lighting Cables Single Conductor, Non-Shielded XLPE 5000V Application For runway, taxiway and approach in underground series airport lighting circuits. At 5000 V rated voltage and maximum conductor temperatures of 90°C for continuous normal operation and 250°C for short circuit. Suitable for use in wet or dry conditions in metallic and non-metallic conduits, ducts, aerial and direct earth burial installations. Construction A bare copper seven wires stranded circular conductor covered with a separator tape has an extruded tracking resistant XLPE (crosslinked polyethylene) insulation, non-jacketed. Also available with conductor shield, insulation shield and / or PVC or PE jacket, upon request. Standard supply lengths are 5000 ft / reel. Other reel lengths are available upon request. Flexible stranding of 19 strands available. Standards Conforms to: • FAA Advisory Circular (AC)150/5345-7E, Specification for L-824 Type C • L824 Type B also available. • NEMA WC71 / ICEA S-96-659-1999 for non-shielded cables. Certification • ETL Certified. • FAA Listed as an Approved Supplier

Item #

Conductor Size AWG

Number of Strands in Conductor

Nominal Diameter of Conductor (in)

DC Resistance of Conductor @ 25°C /MFT

Separator Tape Thickness (mil)

Nominal of Insulation (in)

Nominal Diameter (in)

Ampacity Underground in Duct

ALC-8 ALC-6 ALC-4

8 6 4

7 7 7

0.143 0.180 0.226

0.652 0.411 0.258

0.5 0.5 0.5

110 110 110

0.364 0.401 0.447

64 85 110

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

302 20140110

MEDIUM VOLTAGE CABLES

Option • Shielded • LSOH Jacket

MEDIUM VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

MV-105 Copper EPR Copper Tape Shield 5kV-133%/8kV-100% Insulation Level Applications For installation in tray, trough, conduit, ducts, aerial and direct buried as allowed by the NEC. The cables can be used in main feeder, distribution, and branch circuits for industrial, commercial and electric utility installations. They may operate continuously in wet or dry locations at conductor temperatures not exceeding 105°C, at not more than 140°C. for emergency overload conditions and 250°C during short-circuits. Suitable for systems rated 5kV/8kV, 133% insulation level (grounded systems). Construction Copper concentrically stranded compressed conductor; triple single head extruded conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry cured; bare copper tape shielded; surface printed black PVC jacket. Standards • National Electrical Code (NEC) • UL-1072 MV-105 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • AEIC CS8 • UL listed as Type MV-105 for use in accordance with NEC • Sizes 4/0 AWG and larger are listed and marked “Sunlight-Resistant FOR CT USE” in accordance with NEC

Item #

105-115E2 105-115E1 105-115E1/0 105-115E2/0 105-115E3/0 105-115E4/0 105-115E250 105-115E350 105-115E500 105-115E750 105-115E1000

Size AWG or KCM

Stranding

Insulation Thickness (mil)

Jacket Thickness (mil)

Diameter Over Insulation (in)

Diameter Over Insulation Shield (in)

Diameter Overall (in)

Net Weight per 1000 ft. (lb)

Ampacity 1/C in Cable Tray

Ampacity 1/C Duct Buried

Ampacity 1/C Conduit in Air

2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

7 19 19 19 19 19 37 37 37 61 61

115 115 115 115 115 115 115 115 115 115 115

55 55 55 70 70 70 70 70 70 70 70

0.550 0.590 0.640 0.690 0.740 0.800 0.860 0.960 1.080 1.270 1.420

0.640 0.680 0.720 0.770 0.820 0.870 0.930 1.030 1.170 1.360 1.510

0.840 0.880 0.920 0.980 1.030 1.080 1.140 1.240 1.370 1.560 1.710

510 620 670 790 920 1080 1230 1580 2090 2950 3910

122 137 290 335 385 445 495 610 765 990 1185

165 185 215 245 275 315 345 415 500 610 690

165 190 215 255 290 330 365 440 535 655 755

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

303 20140921

MEDIUM VOLTAGE CABLES

Notes • Ampacities are based on the NEC. • Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105°C conductor, at an ambient temperature of 40°C. • Buried Duct: Three cables per duct operating at 105°C conductor, 20°C ground ambient, earth ρ = 90, 100% load factor. • Conduit in Air: Three cables per isolated conduit in air at 40°C; operating at 105°C conductor (NEC Table 310.73). • CPE or CSPE Jacket available.

MEDIUM VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

MV-105 220 Mil EPR Copper Tape Shield 15kV 133% & 100% Insulation Levels Applications For installation in tray, trough, conduit, ducts, aerial and direct buried as allowed by the NEC. The cables can be used in main feeder, distribution, and branch circuits for industrial, commercial and electric utility installations. They may operate continuously in wet or dry locations at conductor temperatures not exceeding 105°C, at not more than 140°C. for emergency overload conditions and 250°C during short-circuits. Suitable for systems rated 15 kV, 133% & 100% insulation level (grounded systems). Construction Copper concentrically stranded compressed conductor; triple single head extruded conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry cured; bare copper tape shielded; surface printed black PVC jacket. Standards • National Electrical Code (NEC) • UL-1072 MV-105 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • AEIC CS8 • UL listed as Type MV-105 for use in accordance with NEC • Sizes 4/0 AWG and larger are listed and marked “Sunlight-Resistant FOR CT USE” in accordance with NEC

Item #

Size AWG or KCM

220 Mils EPR 133% 105-220E2 105-220E1/0 105-220E2/0 105-220E3/0 105-220E4/0 105-220E250 105-220E350 105-220E500 105-220E750 105-220E1000

2 1/0 2/0 3/0 4/0 250 350 500 750 1000

Stranding

Insulation Thickness (mil)

Jacket Thickness (mil)

Diameter Over Insulation (in)

Diameter Over Insulation Shield (in)

Diameter Overall (in)

Net Weight per 1000 ft. (lb)

Ampacity 1/C in Cable Tray

Ampacity 1/C Duct Buried

Ampacity 1/C Conduit in Air

7 19 19 19 19 37 37 37 61 61

220 220 220 220 220 220 220 220 220 220

70 70 70 70 70 70 70 70 100 100

0.790 0.870 0.910 0.960 1.020 1.080 1.180 1.310 1.500 1.650

0.860 0.920 0.910 1.010 1.080 1.140 1.240 1.370 1.560 1.730

1.080 1.140 1.180 1.230 1.290 1.350 1.470 1.600 1.790 2.020

700 870 930 1070 1250 1420 1800 2360 3360 4290

122 290 335 385 445 495 610 756 990 1185

165 215 245 275 315 345 415 500 610 690

165 215 255 290 330 365 440 535 655 755

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

304 20140921

MEDIUM VOLTAGE CABLES

Notes • Ampacities are based on the NEC. • Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105°C conductor, at an ambient temperature of 40°C. • Buried Duct: Three cables per duct operating at 105°C conductor, 20°C ground ambient, earth ρ = 90, 100% load factor. • Conduit in Air: Three cables per isolated conduit in air at 40°C; operating at 105°C conductor (NEC Table 310.73). • CPE or CSPE Jacket available.

MV-105 220 Mil EPR Copper Tape Shield 15kV 133% & 100% Insulation Levels Item #

Size AWG or KCM

2 1/0 2/0 3/0 4/0 250 350 500 750 1000

Insulation Thickness (mil)

Jacket Thickness (mil)

Diameter Over Insulation (in)

Diameter Over Insulation Shield (in)

Diameter Overall (in)

Net Weight per 1000 ft. (lb)

Ampacity 1/C in Cable Tray

Ampacity 1/C Duct Buried

Ampacity 1/C Conduit in Air

7 19 19 19 19 37 37 37 61 61

175 175 175 175 175 175 175 175 175 175

70 70 70 70 70 70 70 70 100 100

0.700 0.780 0.820 0.870 0.930 0.990 1.090 1.220 1.410 1.560

0.770 0.860 0.900 0.950 1.010 1.070 1.190 1.320 1.510 1.680

1.000 1.050 1.090 1.140 1.200 1.260 1.380 1.510 1.700 1.930

620 780 680 1000 1170 1320 1720 2270 3140 4170

122 290 335 385 445 495 610 756 990 1185

165 215 245 275 315 345 415 500 610 690

165 215 255 290 330 365 440 535 655 755

MEDIUM VOLAGE CABLES

175 Mils EPR 100% 105-175E2 105-175E1/0 105-175E2/0 105-175E3/0 105-175E4/0 105-175E250 105-175E350 105-175E500 105-175E750 105-175E1000

Stranding

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 304 20140921

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

MV-105 Copper EPR Copper Tape Shield 35kV 133% & 100% Insulation Level Applications For installation in tray, trough, conduit, ducts, aerial and direct buried as allowed by the NEC. The cables can be used in main feeder, distribution, and branch circuits for industrial, commercial and electric utility installations. They may operate continuously in wet or dry locations at conductor temperatures not exceeding 105°C, at not more than 140°C for emergency overload conditions and 250°C during short-circuits. Suitable for systems rated 35 kV, 133% & 100% insulation level (grounded systems). Construction Copper concentrically stranded compressed conductor; triple single head extruded conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry cured; bare copper tape shielded; surface printed black PVC jacket. Standards • National Electrical Code (NEC) • UL-1072 MV-105 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • AEIC CS8 • UL listed as Type MV-105 for use in accordance with NEC • Sizes 4/0 AWG and larger are listed and marked “Sunlight-Resistant FOR CT USE” in accordance with NEC

Item #

Size AWG or KCM

420 Mils EPR 133% 105-420E1/0 105-420E2/0 105-420E3/0 105-420E4/0 105-420E250 105-420E350 105-420E500 105-420E750 105-420E1000

1/0 2/0 3/0 4/0 250 350 500 750 1000

Stranding

Minimum Point Insulation (mil)

Minimum Point Jacket (mil)

Diameter Over Insulation (in)

Diameter Over Insulation Shield (in)

Diameter Overall (in)

Net Weight /MFT (lb)

Ampacity 1/C in Cable Tray

Ampacity 1/C Duct Buried

Ampacity 1/C Conduit in Air

19 19 19 19 37 37 37 61 61

420 420 420 420 420 420 420 420 420

70 70 70 70 100 100 100 100 100

1.250 1.310 1.360 1.410 1.470 1.580 1.700 1.890 2.040

1.340 1.390 1.450 1.500 1.570 1.680 1.820 2.010 2.160

1.550 1.600 1.650 1.710 1.840 1.930 2.070 2.280 2.430

1370 1500 1650 1840 2140 2590 3240 4260 5230

N/A N/A N/A 445 495 610 765 990 1185

215 245 275 315 345 415 500 610 690

215 255 290 330 365 440 535 655 755

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

305 20140921

MEDIUM VOLTAGE CABLES

Notes • Ampacities are based on the NEC. • Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105°C conductor, at an ambient temperature of 40°C. • Buried Duct: Three cables per duct operating at 105°C conductor, 20°C ground ambient, earth ρ = 90, 100% load factor. • Conduit in Air: Three cables per isolated conduit in air at 40°C; operating at 105°C conductor (NEC Table 310.73).

MV-105 Copper EPR Copper Tape Shield 35kV 133% & 100% Insulation Level Item #

Size AWG or KCM

1/0 2/0 3/0 4/0 250 350 500 750 1000

Minimum Point Insulation (mil)

Minimum Point Jacket (mil)

Diameter Over Insulation (in)

Diameter Over Insulation Shield (in)

Diameter Overall (in)

Net Weight /MFT (lb)

Ampacity 1/C in Cable Tray

Ampacity 1/C Duct Buried

Ampacity 1/C Conduit in Air

19 19 19 19 37 37 37 61 61

345 345 345 345 345 345 345 345 345

70 70 70 70 70 100 100 100 100

1.110 1.150 1.200 1.260 1.330 1.430 1.550 1.740 1.890

1.200 1.250 1.290 1.340 1.420 1.520 1.660 1.860 2.020

1.390 1.440 1.490 1.550 1.600 1.780 1.910 2.120 2.270

1180 1300 1460 1650 1830 2230 2930 3960 4920

N/A N/A N/A 445 495 610 765 990 1185

215 245 275 315 345 415 500 610 690

215 255 290 330 365 440 535 655 755

MEDIUM VOLAGE CABLES

345 mils EPR 100% 105-345E1/0 105-345E2/0 105-345E3/0 105-345E4/0 105-345E250 105-345E350 105-345E500 105-345E750 105-345E1000

Stranding

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 305 20140921

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

URD 175 Mil TRXLP 15 kV 100% LLDPE Jacket AEIC CS-8 Applications For use on single phase and three phase primary underground distribution systems operating at 15kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in ducts. Construction Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed. Standards • AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV • ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V • ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors • ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables • UL-1072 MV90 Options • EPR insulation • Filled strand • Cable core water blocking

Item #

Code Name

Cond. Size AWG

Full Neutral Aluminum Conductor 175-TRXPL-01 Arch 2 175-TRXPL-02 Cezanne 2 175-TRXPL-03 Soffit 1 175-TRXPL-04 Botticelli 1 175-TRXPL-05 Joists 1/0 175-TRXPL-06 Van Gogh 1/0 175-TRXPL-07 Goya 2/0 175-TRXPL-08 El Greco 3/0 175-TRXPL-09 Corot 4/0 1/3 Neutral Aluminum Conductor 175-TRXLP-10 Gable 1/0 175-TRXLP-11 N/A 1/0 175-TRXLP-12 N/A 2/0 175-TRXLP-13 N/A 3/0 175-TRXLP-14 N/A 4/0 175-TRXLP-15 Degas 250 175-TRXLP-16 Hals 350 175-TRXLP-17 Bosch 500 175-TRXLP-18 Vernet 750 175-TRXLP-19 N/A 1000

Cond. Stranding

Copper Neutral No.of Wires

Copper Neutral Size AWG

Conductor Diameter Diameter Diameter Diameter Diameter Over Over Over Over Insulation Insulation Neutral Embedded (in) Shield Wires Jacket (in) (in) (in)

Total Total Ampacity Ampacity Ampacity. w/o w/Embedded 1/C 1/C 1/C Jacket Jacket in Cable Duct Conduit. Weight Weight Tray Buried in Air (lb) (lb)

Solid 7 Solid 19 Solid 19 19 19 19

10 10 13 13 16 16 13 16 20

14 14 14 14 14 14 12 12 12

0.258 0.283 0.289 0.322 0.325 0.362 0.405 0.456 0.512

0.670 0.695 0.700 0.730 0.735 0.770 0.815 0.865 0.920

0.750 0.775 0.780 0.810 0.815 0.850 0.895 0.945 1.000

0.878 0.903 0.908 0.938 0.943 0.978 1.057 1.107 1.162

0.978 1.003 1.008 1.038 1.043 1.078 1.157 1.207 1.262

356 370 424 437 494 510 616 730 875

477 487 543 556 615 632 760 874 1030

170 170 195 195 230 230 270 295 335

115 115 140 140 155 155 185 210 240

100 100 123 123 135 135 162 184 210

Solid 19 19 19 19 37 37 37 61 61

6 6 7 9 11 13 11 16 15 20

14 14 14 14 14 14 12 12 10 10

0.325 0.362 0.405 0.456 0.512 0.558 0.660 0.789 0.968 1.117

0.735 0.770 0.815 0.865 0.920 0.980 1.080 1.210 1.400 1.545

0.815 0.850 0.895 0.945 1.000 1.060 1.200 1.330 1.520 1.705

0.943 0.978 1.023 1.073 1.128 1.188 1.362 1.492 1.724 1.909

1.043 1.078 1.123 1.173 1.228 1.288 1.462 1.562 1.884 2.069

356 373 434 510 598 684 913 1207 1685 2210

460 515 575 655 759 889 1175 1498 2057 2516

230 230 250 280 320 345 405 460 515 565

165 165 190 215 245 270 325 385 475 540

145 145 167 189 215 237 285 338 417 475

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

306 20180401

MEDIUM VOLTAGE CABLES

Notes • Ampacities are based on the NEC. • Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105°C conductor, at an ambient temperature of 40°C. • Buried Duct: Three cables per duct operating at 105°C conductor, 20°C ground ambient, earth ρ = 90, 100% load factor. • Conduit in Air: Three cables per isolated conduit in air at 40°C; operating at 105°C conductor (NEC Table 310.73). • Maximum conductor temperature: 90°C normal continuous, 130°C overload, 250°C short circuit.

URD 175 Mil TRXLP 15 kV 100% LLDPE Jacket AEIC CS-8

MEDIUM VOLAGE CABLES

Item #

Code Name

Cond. Size AWG

Full Neutral Copper Conductor 175-TRXLP-20 Titan 2 175-TRXLP-21 Monet 1 175-TRXLP-22 Raphael 1/0 175-TRXLP-23 Rubens 2/0 175-TRXLP-24 Bruegel 3/0 175-TRXLP-25 N/A 4/0 1/3 Neutral Copper Conductor 175-TRXLP-26 N/A 1/0 175-TRXLP-27 N/A 2/0 175-TRXLP-28 N/A 3/0 175-TRXLP-29 Holbein 4/0 175-TRXLP-30 Moreau 250 175-TRXLP-31 McNeil 350 175-TRXLP-32 Daumier 500 175-TRXLP-33 N/A 750 175-TRXLP-34 N/A 1000

Cond. Stranding

Copper Neutral No.of Wires

Copper Neutral Size AWG

Conductor Diameter Diameter Diameter Diameter Diameter Over Over Over Over Insulation Insulation Neutral Embedded (in) Shield Wires Jacket (in) (in) (in)

Total Total Ampacity Ampacity Ampacity. w/o w/Embedded 1/C 1/C 1/C Jacket Jacket in Cable Duct Conduit. Weight Weight Tray Buried in Air (lb) (lb)

7 19 19 19 19 19

16 13 16 20 25 32

14 12 12 12 12 12

0.283 0.322 0.362 0.405 0.456 0.512

0.695 0.730 0.770 0.815 0.865 0.920

0.775 0.810 0.850 0.895 0.945 1.000

0.902 0.972 1.012 1.057 1.107 1.162

1.003 1.072 1.112 1.157 1.207 1.262

642 504 923 1107 1334 1642

700 570 993 1176 1402 1708

225 260 295 330 375 430

160 185 210 240 270 305

140 162 185 210 237 268

19 19 19 19 37 37 37 61 61

9 11 14 11 13 12 17 25 33

14 14 14 12 12 10 10 10 10

0.362 0.405 0.456 0.512 0.558 0.660 0.789 0.968 1.117

0.770 0.815 0.865 0.920 0.980 1.080 1.210 1.400 1.545

0.850 0.899 0.945 1.000 1.060 1.200 1.330 1.520 1.705

0.978 1.023 1.073 1.162 1.222 1.404 1.534 1.724 1.945

1.078 1.123 1.173 1.262 1.322 1.504 1.694 1.884 2.106

708 836 1002 1227 1427 1904 2664 3794 4948

777 907 1074 1317 1546 2055 2823 3964 5127

290 320 350 390 415 475 525 560 600

210 240 275 315 340 415 480 530 590

185 210 241 276 298 364 420 465 518

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 306 201480401

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

URD 175 Mil EPR 15 kV 100% LLDPE Jacket AEIC CS-8 Applications For use on single phase and three phase primary underground distribution systems operating at 15kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in ducts. Construction Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed. Standards • AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46kV • ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V • ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors • ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables • UL-1072 MV90 Notes. • Maximum conductor temperature: 90°C normal continuous, 130°C overload, 250°C short circuit.

Item #

Cond. Stranding

Full Neutral Aluminum Conductor 175-EPR-01 2 Solid 175-EPR-02 2 7 175-EPR-03 1 Solid 175-EPR-04 1 19 175-EPR-05 1/0 Solid 175-EPR-06 1/0 19 175-EPR-07 2/0 19 175-EPR-08 3/0 19 175-EPR-09 4/0 19 1/3 Neutral Aluminum Conductor 175-EPR-10 1/0 Solid 175-EPR-11 1/0 19 175-EPR-12 2/0 19 175-EPR-13 3/0 19 175-EPR-14 4/0 19 175-EPR-15 250 37 175-EPR-16 350 37 175-EPR-17 500 37 175-EPR-18 750 61 175-EPR-19 1000 61

Copper Neutral No.of Wires

Copper Neutral Size AWG

Conductor Diameter Diameter Diameter Over Over Insulation Insulation (in) Shield (in)

10 10 13 13 16 16 13 16 20

14 14 14 14 14 14 12 12 12

0.258 0.290 0.289 0.330 0.325 0.370 0.420 0.470 0.530

0.670 0.690 0.700 0.730 0.735 0.770 0.820 0.870 0.930

6 6 7 9 11 13 11 16 15 20

14 14 14 14 14 14 12 12 10 10

0.325 0.370 0.420 0.470 0.530 0.570 0.680 0.810 0.990 1.140

0.735 0.770 0.820 0.870 0.930 0.990 1.090 1.220 1.410 1.570

Diameter Diameter Over Over Neutral Embedded Wires Jacket (in) (in)

Total Total Ampacity w/o w/Embedded 1/C Jacket Jacket in Cable Weight Weight Tray (lb) (lb)

Ampacity Ampacity. 1/C 1/C Duct Conduit. Buried in Air

0.750 0.750 0.780 0.800 0.815 0.840 0.880 0.930 0.990

0.878 0.880 0.908 0.930 0.943 0.970 1.010 1.100 1.150

0.978 0.980 1.008 1.030 1.043 1.070 1.110 1.200 1.260

451 455 520 536 594 615 732 848 1009

512 518 581 600 656 680 810 927 1090

170 170 195 195 230 230 270 295 335

115 115 140 140 155 155 185 210 240

100 100 123 123 135 135 162 184 210

0.815 0.840 0.880 0.930 0.990 1.050 1.190 1.330 1.520 1.710

0.943 0.970 0.010 0.100 0.130 0.170 0.360 1.490 1.720 1.920

1.043 1.070 1.110 1.200 1.230 1.270 1.460 1.590 1.890 2.030

471 482 552 630 737 849 1111 1442 1959 2524

539 547 630 709 818 959 1253 1590 2149 2727

230 230 250 280 320 345 405 460 515 565

165 165 190 215 245 270 325 385 475 540

145 145 167 189 215 237 285 338 417 475

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

307 20180401

MEDIUM VOLTAGE CABLES

Cond. Size AWG

URD 175 Mil EPR 15 kV 100% LLDPE Jacket AEIC CS-8 Item #

Cond. Size AWG

Copper Neutral No.of Wires

Copper Neutral Size AWG

Conductor Diameter Diameter Diameter Over Over Insulation Insulation (in) Shield (in)

7 19 19 19 19 19

16 13 16 20 25 32

14 12 12 12 12 12

0.290 0.330 0.370 0.420 0.470 0.530

0.690 0.730 0.770 0.820 0.870 0.930

19 19 19 19 37 37 37 61 61

9 11 14 11 13 12 17 25 33

14 14 14 12 12 10 10 10 10

0.370 0.420 0.470 0.530 0.570 0.680 0.810 0.990 1.140

0.770 0.820 0.870 0.930 0.990 1.090 1.220 1.410 1.570

Diameter Diameter Over Over Neutral Embedded Wires Jacket (in) (in)

Total Total Ampacity w/o w/Embedded 1/C Jacket Jacket in Cable Weight Weight Tray (lb) (lb)

Ampacity Ampacity. 1/C 1/C Duct Conduit. Buried in Air

0.750 0.800 0.840 0.880 0.930 0.990

0.880 0.930 0.970 1.010 1.100 1.150

0.980 1.030 1.070 1.110 1.200 1.260

677 811 960 1166 1398 1703

740 875 1025 1244 1477 1784

225 260 295 330 375 430

160 210 210 240 270 305

140 185 185 210 237 268

0.840 0.880 0.930 0.990 1.050 1.190 1.330 1.520 1.710

0.970 1.010 1.100 1.150 1.190 1.360 1.490 1.720 1.920

1.070 1.110 1.200 1.250 1.290 1.460 1.590 1.890 2.030

749 891 1056 1267 1487 2022 2712 3873 5028

814 969 1135 1348 1597 2164 2860 4063 5231

290 320 350 390 415 475 525 560 600

210 240 275 315 340 415 480 530 590

185 210 241 276 298 364 420 465 518

MEDIUM VOLAGE CABLES

Full Neutral Copper Conductor 175-EPR-20 2 175-EPR-21 1 175-EPR-22 1/0 175-EPR-23 2/0 175-EPR-24 3/0 175-EPR-25 4/0 1/3 Neutral Copper Conductor 175-EPR-26 1/0 175-EPR-27 2/0 175-EPR-28 3/0 175-EPR-29 4/0 175-EPR-30 250 175-EPR-31 350 175-EPR-32 500 175-EPR-33 750 175-EPR-34 1000

Cond. Stranding

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 307 20180401

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

URD 220 Mil TRXLP 15kV 133% LLDPE Jacket AEIC CS-8 Applications For use on single phase and three phase primary underground distribution systems operating at 15kV phase to phase at 100% and 133% insulation level. Suitable for either direct burial or installation in ducts. Construction Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene) insulation and easy strippable insulation shield, all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed. Standards • AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV • ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V • ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors • ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables • UL-1072 MV90 Options • EPR insulation • Filled strand • Cable core water blocking

Item #

Cond. Size AWG

Cond. Stranding

Full Neutral Aluminum Conductor 220-TRXLP-01 2 Solid 220-TRXLP-02 2 7 220-TRXLP-03 1 Solid 220-TRXLP-04 1 19 220-TRXLP-05 1/0 Solid 220-TRXLP-06 1/0 19 220-TRXLP-07 2/0 19 220-TRXLP-08 3/0 19 220-TRXLP-09 4/0 19 1/3 Neutral Aluminum Conductor 220-TRXLP-10 1/0 Solid 220-TRXLP-11 1/0 19 220-TRXLP-12 2/0 19 220-TRXLP-13 3/0 19 220-TRXLP-14 4/0 19 220-TRXLP-15 250 37 220-TRXLP-16 350 37 220-TRXLP-17 500 37 220-TRXLP-18 750 61 220-TRXLP-19 1000 61

Copper Neutral No.of Wires

Copper Neutral Size AWG

Conductor Diameter Diameter Diameter Over Over Insulation Insulation (in) Shield (in)

10 10 13 13 16 16 13 16 20

14 14 14 14 14 14 12 12 12

0.258 0.283 0.289 0.322 0.325 0.362 0.405 0.456 0.512

0.760 0.785 0.790 0.820 0.825 0.860 0.905 0.955 1.010

6 6 7 9 11 13 11 16 15 20

14 14 14 14 14 14 12 12 10 10

0.325 0.362 0.405 0.456 0.512 0.558 0.660 0.789 0.968 1.117

0.825 0.860 0.905 0.955 1.010 1.070 1.170 1.300 1.490 1.635

Diameter Diameter Over Over Neutral Embedded Wires Jacket (in) (in)

Total Total Ampacity w/o w/Embedded 1/C Jacket Jacket in Cable Weight Weight Tray (lb) (lb)

Ampacity Ampacity. 1/C 1/C Duct Conduit. Buried in Air

0.840 0.865 0.870 0.900 0.905 0.940 0.985 1.035 1.090

0.968 0.993 0.998 1.028 1.033 1.068 1.147 1.197 1.252

1.068 1.093 1.098 1.128 1.133 1.168 1.247 1.297 1.352

401 415 470 487 544 562 670 787 934

537 549 604 619 680 697 830 946 1148

170 170 195 195 230 230 270 295 335

115 115 140 140 155 155 185 210 240

100 100 123 123 135 135 162 184 210

0.905 0.940 0.985 1.035 1.090 1.190 1.290 1.420 1.610 1.795

1.033 1.068 1.113 1.163 1.218 1.318 1.452 1.582 1.814 1.999

1.133 1.168 1.213 1.263 1.318 1.418 1.612 1.742 1.974 2.159

423 441 490 567 656 781 987 1284 1774 2301

562 580 643 725 842 1013 1266 1597 2230 2718

230 230 250 280 320 345 405 460 515 565

165 165 190 215 245 270 325 385 475 540

145 145 167 189 215 237 285 338 417 475

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

308 20180401

MEDIUM VOLTAGE CABLES

Notes • Ampacities are based on the NEC. • Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105°C conductor, at an ambient temperature of 40°C. • Buried Duct: Three cables per duct operating at 105°C conductor, 20°C ground ambient, earth ρ = 90, 100% load factor. • Conduit in Air: Three cables per isolated conduit in air at 40°C; operating at 105°C conductor (NEC Table 310.73). • Maximum conductor temperature: 90°C normal continuous, 130°C overload, 250°C short circuit.

URD 220 Mil TRXLP 15kV 133% LLDPE Jacket AEIC CS-8

MEDIUM VOLAGE CABLES

Item #

Cond. Size AWG

Full Neutral Copper Conductor 220-TRXLP-20 2 220-TRXLP-21 1 220-TRXLP-22 1/0 220-TRXLP-23 2/0 220-TRXLP-24 3/0 220-TRXLP-25 4/0 1/3 Neutral Copper Conductor 220-TRXLP-26 1/0 220-TRXLP-27 2/0 220-TRXLP-28 3/0 220-TRXLP-29 4/0 220-TRXLP-30 250 220-TRXLP-31 350 220-TRXLP-32 500 220-TRXLP-33 750 220-TRXLP-34 1000

Cond. Stranding

Copper Neutral No.of Wires

Copper Neutral Size AWG

Conductor Diameter Diameter Diameter Over Over Insulation Insulation (in) Shield (in)

7 19 19 19 19 19

16 13 16 20 25 32

14 12 12 12 12 12

0.283 0.322 0.362 0.405 0.456 0.512

0.785 0.820 0.860 0.905 0.955 1.010

19 19 19 19 37 37 37 61 61

9 11 14 11 13 12 17 25 33

14 14 14 12 12 10 10 10 10

0.362 0.405 0.456 0.512 0.558 0.660 0.789 0.968 1.117

0.860 0.905 0.955 1.010 1.070 1.170 1.300 1.490 1.635

Diameter Diameter Over Over Neutral Embedded Wires Jacket (in) (in)

Total Total Ampacity w/o w/Embedded 1/C Jacket Jacket in Cable Weight Weight Tray (lb) (lb)

Ampacity Ampacity. 1/C 1/C Duct Conduit. Buried in Air

0.865 0.900 0.940 0.985 1.035 1.090

0.993 1.062 1.102 1.147 1.197 1.294

1.093 1.162 1.202 1.247 1.293 1.394

695 559 982 1169 1399 1747

760 633 1060 1246 1475 1825

225 260 295 330 375 430

160 185 210 240 270 305

140 162 185 210 237 268

0.940 0.985 1.035 1.090 1.190 1.290 1.420 1.610 1.795

1.068 1.113 1.163 1.294 1.352 1.494 1.624 1.814 1.999

1.168 1.213 1.263 1.394 1.452 1.654 1.784 1.974 2.159

767 897 1066 1333 1539 1987 2754 3952 5061

842 975 1145 1434 1673 2149 2924 4138 5251

290 320 350 390 415 475 525 560 600

210 240 275 315 340 415 480 530 590

185 210 241 276 298 364 420 465 518

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 308 20180401

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

URD 220 Mil EPR 15kV 133% LLDPE Jacket AEIC CS-8 Applications For use on single phase and three phase primary underground distribution systems operating at 15kV phase to phase at 100% and 133% insulation level. Suitable for either direct burial or installation in ducts. Construction Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed. Standards • AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV • ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V • ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors • ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables • UL-1072 MV90 Notes • Maximum conductor temperature: 90°C normal continuous, 130°C overload, 250°C short circuit.

Item #

Cond. Stranding

Full Neutral Aluminum Conductor 220-EPR-01 2 Solid 220-EPR-02 2 7 220-EPR-03 1 Solid 220-EPR-04 1 19 220-EPR-05 1/0 Solid 220-EPR-06 1/0 19 220-EPR-07 2/0 19 220-EPR-08 3/0 19 220-EPR-09 4/0 19 1/3 Neutral Aluminum Conductor 220-EPR-10 1/0 Solid 220-EPR-11 1/0 19 220-EPR-12 2/0 19 220-EPR-13 3/0 19 220-EPR-14 4/0 19 220-EPR-15 250 37 220-EPR-16 350 37 220-EPR-17 500 37 220-EPR-18 750 61 220-EPR-19 1000 61

Copper Neutral No.of Wires

Copper Neutral Size AWG

Conductor Diameter Diameter Diameter Over Over Insulation Insulation (in) Shield (in)

10 10 13 13 16 16 13 16 20

14 14 14 14 14 14 12 12 12

0.258 0.290 0.289 0.330 0.325 0.370 0.420 0.470 0.530

0.760 0.780 0.790 0.830 0.825 0.870 0.910 0.960 1.020

6 6 7 9 11 13 11 16 15 20

14 14 14 14 14 14 12 12 10 10

0.325 0.370 0.420 0.470 0.530 0.570 0.680 0.810 0.990 1.140

0.825 0.870 0.910 0.960 1.020 1.080 1.180 1.310 1.510 1.660

Diameter Diameter Over Over Neutral Embedded Wires Jacket (in) (in)

Total Total Ampacity w/o w/Embedded 1/C Jacket Jacket in Cable Weight Weight Tray (lb) (lb)

Ampacity Ampacity. 1/C 1/C Duct Conduit. Buried in Air

0.840 0.840 0.870 0.890 0.905 0.930 0.980 1.030 1.120

0.968 0.970 0.998 1.020 1.033 1.060 1.100 1.190 1.290

1.068 1.075 1.098 1.121 1.133 1.161 1.207 1.291 1.389

518 534 587 606 665 691 808 926 1135

585 603 655 676 733 764 895 1015 1228

170 170 195 195 230 230 270 295 335

115 115 140 140 155 155 185 210 240

100 100 123 123 135 135 162 184 210

0.905 0.930 0.980 1.030 1.120 1.180 1.290 1.420 1.610 1.810

1.033 1.060 1.100 1.190 1.270 1.370 1.450 1.580 1.810 2.010

1.133 1.161 1.207 1.291 1.369 1.469 1.552 1.746 1.980 2.175

541 558 628 708 863 978 1219 1555 2144 2667

616 631 715 797 956 1092 1369 1715 2349 2882

230 230 250 280 320 345 405 460 515 565

165 165 190 215 245 270 325 385 475 540

145 145 167 189 215 237 285 338 417 475

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

309 20180401

MEDIUM VOLTAGE CABLES

Cond. Size AWG

URD 220 Mil EPR 15kV 133% LLDPE Jacket AEIC CS-8

MEDIUM VOLAGE CABLES

Item #

Cond. Size AWG

Cond. Stranding

Copper Neutral No.of Wires

Copper Neutral Size AWG

Conductor Diameter Diameter Diameter Over Over Insulation Insulation (in) Shield (in)

Full Neutral Copper Conductor 220-EPR-20 2 220-EPR-21 1 220-EPR-22 1/0 220-EPR-23 2/0 220-EPR-24 3/0 220-EPR-25 4/0

7 19 19 19 19 19

16 13 16 20 25 32

14 12 12 12 12 12

0.290 0.330 0.370 0.420 0.470 0.530

0.780 0.830 0.870 0.910 0.960 1.020

1/3 Neutral Copper Conductor 220-EPR-26 1/0 220-EPR-27 2/0 220-EPR-28 3/0 220-EPR-29 4/0 220-EPR-30 250 220-EPR-31 350 220-EPR-32 500 220-EPR-33 750 220-EPR-34 1000

19 19 19 19 37 37 37 61 61

9 11 14 11 13 12 17 25 33

14 14 14 12 12 10 10 10 10

0.370 0.420 0.470 0.530 0.570 0.680 0.810 0.990 1.140

0.870 0.910 0.960 1.020 1.080 1.180 1.310 1.510 1.660

Diameter Diameter Over Over Neutral Embedded Wires Jacket (in) (in)

Total Total Ampacity w/o w/Embedded 1/C Jacket Jacket in Cable Weight Weight Tray (lb) (lb)

Ampacity Ampacity. 1/C 1/C Duct Conduit. Buried in Air

0.840 0.890 0.930 0.980 1.030 1.120

0.970 1.040 1.080 1.100 1.190 1.290

1.075 1.141 1.181 1.207 1.291 1.389

756 881 1036 1242 1476 1829

825 951 1109 1329 1565 1922

225 260 295 330 375 430

160 185 210 240 270 305

140 162 185 210 237 268

0.930 0.980 1.030 1.120 1.180 1.290 1.420 1.610 1.810

1.080 1.100 1.190 1.310 1.410 1.490 1.620 1.810 2.010

1.181 1.207 1.291 1.410 1.509 1.592 1.786 1.980 2.175

825 967 1134 1393 1616 2130 2825 4058 5171

898 1054 1223 1486 1730 2280 2985 4263 5386

290 320 350 390 415 475 525 560 600

210 240 275 315 340 415 480 530 590

185 210 241 276 298 364 420 465 518

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 309 20180401

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

URD 260 Mil TRXLP 25kV 100% LLDPE Jacket AEIC CS-8 Applications For use on single phase and three phase primary underground distribution systems operating at 25kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in ducts. Construction Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, TRXLPE (tree-retardant cross-linked polyethylene insulation and easy strippable insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed. Standards • AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV • ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V • ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors • ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables • UL-1072 MV90 Options • EPR insulation • Filled strand • Cable core water blocking

Item #

Code Name

Cond. Size AWG

Full Neutral Aluminum Conductor 260-TRXLP-01 N/A 1 260-TRXLP-02 Liszt 1 260-TRXLP-03 N/A 1/0 260-TRXLP-04 Verdi 1/0 260-TRXLP-05 Ives 2/0 260-TRXLP-06 Bach 3/0 260-TRXLP-07 Mozart 4/0 1/3 Neutral Aluminum Conductor 260-TRXLP-08 N/A 1/0 260-TRXLP-09 N/A 1/0 260-TRXLP-10 N/A 2/0 260-TRXLP-11 N/A 3/0 260-TRXLP-12 N/A 4/0 260-TRXLP-13 Wagner 250 260-TRXLP-14 Gould 350 260-TRXLP-15 Schubert 500 260-TRXLP-16 Strauss 750 260-TRXLP-17 N/A 1000

Cond. Stranding

Copper Neutral No.of Wires

Copper Neutral Size AWG

Conductor Diameter Diameter Diameter Diameter Diameter Over Over Over Over Insulation Insulation Neutral Embedded (in) Shield Wires Jacket (in) (in) (in)

Total Total Ampacity Ampacity Ampacity. w/o w/Embedded 1/C 1/C 1/C Jacket Jacket in Cable Duct Conduit. Weight Weight Tray Buried in Air (lb) (lb)

Solid 19 Solid 19 19 19 19

13 13 16 16 13 16 20

14 14 14 14 12 12 12

0.289 0.322 0.325 0.362 0.405 0.456 0.512

0.870 0.900 0.905 0.940 0.985 1.035 1.090

0.950 0.980 0.989 1.022 1.065 1.155 1.210

1.078 1.108 1.117 1.150 1.227 1.317 1.372

1.178 1.208 1.217 1.250 1.327 1.417 1.472

518 535 590 614 722 875 1025

671 687 748 767 905 1065 1241

195 195 220 220 250 290 325

145 145 165 165 190 210 245

127 127 145 145 167 185 215

Solid 19 19 19 19 37 37 37 61 61

6 6 7 9 11 13 11 16 15 20

14 14 14 14 14 14 12 12 10 10

0.325 0.362 0.405 0.456 0.512 0.558 0.660 0.789 0.968 1.117

0.905 0.940 0.985 1.035 1.090 1.160 1.260 1.390 1.580 1.725

0.989 1.022 1.065 1.155 1.210 1.280 1.380 1.510 1.740 1.885

1.117 1.150 1.193 1.283 1.338 1.408 1.542 1.672 1.944 2.089

1.217 1.250 1.293 1.383 1.438 1.508 1.702 1.832 2.104 2.249

460 475 540 655 750 852 1060 1369 1920 2405

631 650 715 842 966 1117 1380 1721 2373 2870

225 225 250 275 310 335 395 445 515 560

165 165 180 205 240 260 325 390 475 525

145 145 158 180 210 228 285 342 417 460

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

310 20180401

MEDIUM VOLTAGE CABLES

Notes • Ampacities are based on the NEC. • Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105°C conductor, at an ambient temperature of 40°C. • Buried Duct: Three cables per duct operating at 105°C conductor, 20°C ground ambient, earth ρ = 90, 100% load factor. • Conduit in Air: Three cables per isolated conduit in air at 40°C; operating at 105°C conductor (NEC Table 310.73). • Maximum conductor temperature: 90°C normal continuous, 130°C overload, 250°C short circuit.

URD 260 Mil TRXLP 25kV 100% LLDPE Jacket AEIC CS-8 Item #

Code Name

Cond. Size AWG

Copper Neutral No.of Wires

Copper Neutral Size AWG

Conductor Diameter Diameter Diameter Diameter Diameter Over Over Over Over Insulation Insulation Neutral Embedded (in) Shield Wires Jacket (in) (in) (in)

Total Total Ampacity Ampacity Ampacity. w/o w/Embedded 1/C 1/C 1/C Jacket Jacket in Cable Duct Conduit. Weight Weight Tray Buried in Air (lb) (lb)

19 19 19 19 19

13 16 20 25 32

12 12 12 12 12

0.322 0.362 0.405 0.456 0.512

0.900 0.940 0.985 1.035 1.090

0.980 1.022 1.065 1.155 1.210

1.142 1.184 1.227 1.317 1.372

1.242 1.284 1.327 1.417 1.472

615 1044 1232 1502 1828

701 1133 1321 1594 1919

245 280 315 360 415

185 215 240 275 315

162 189 210 241 276

19 19 19 19 37 37 37 61 61

9 11 14 11 13 12 17 25 33

14 14 14 12 12 10 10 10 10

0.352 0.405 0.456 0.512 0.558 0.660 0.789 0.968 1.117

0.940 0.985 1.035 1.090 1.160 1.260 1.390 1.580 1.725

1.022 1.065 1.155 1.210 1.280 1.380 1.510 1.741 1.885

1.150 1.193 1.283 1.371 1.442 1.584 1.714 1.944 2.089

1.250 1.293 1.383 1.471 1.602 1.744 1.874 2.104 2.249

826 960 1166 1414 1628 2083 2858 4071 5190

912 1048 1261 1528 1780 2266 3050 4280 5404

275 310 345 385 410 460 520 567 625

215 250 285 320 345 405 470 450 615

189 220 250 280 303 355 412 483 540

MEDIUM VOLAGE CABLES

Full Neutral Copper Conductor 260-TRXLP-18 Handel 1 260-TRXLP-19 Haydn 1/0 260-TRXLP-20 Brahms 2/0 260-TRXLP-21 Ravel 3/0 260-TRXLP-22 Chopin 4/0 1/3 Neutral Copper Conductor 260-TRXLP-23 N/A 1/0 260-TRXLP-24 N/A 2/0 260-TRXLP-25 N/A 3/0 260-TRXLP-26 N/A 4/0 260-TRXLP-27 Dufay 250 260-TRXLP-28 Schuetz 350 260-TRXLP-29 Lully 500 260-TRXLP-30 N/A 750 260-TRXLP-31 N/A 1000

Cond. Stranding

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 310 20180401

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

URD 260 Mil EPR 25kV 100% LLDPE Jacket AEIC CS-8 Applications For use on single phase and three phase primary underground distribution systems operating at 25kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in ducts. Construction Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed. Standards • AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV • ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V • ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors • ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables • UL-1072 MV90 Notes • Maximum conductor temperature: 90°C normal continuous, 130°C overload, 250°C short circuit.

Item #

Cond. Stranding

Full Neutral Aluminum Conductor 260-EPR-01 1 Solid 260-EPR-02 1 19 260-EPR-03 1/0 Solid 260-EPR-04 1/0 19 260-EPR-05 2/0 19 260-EPR-06 3/0 19 260-EPR-07 4/0 19 1/3 Neutral Aluminum Conductor 260-EPR-08 1/0 Solid 260-EPR-09 1/0 19 260-EPR-10 2/0 19 260-EPR-11 3/0 19 260-EPR-12 4/0 19 260-EPR-13 250 37 260-EPR-14 350 37 260-EPR-15 500 37 260-EPR-16 750 61 260-EPR-17 1000 61

Copper Neutral No.of Wires

Copper Neutral Size AWG

Conductor Diameter Diameter Diameter Over Over Insulation Insulation (in) Shield (in)

13 13 16 16 13 16 20

14 14 14 14 12 12 12

0.289 0.330 0.325 0.370 0.420 0.470 0.530

0.870 0.910 0.905 0.950 0.990 1.040 1.100

6 6 7 9 11 13 11 16 15 20

14 14 14 14 14 14 12 12 10 10

0.325 0.370 0.420 0.470 0.530 0.570 0.680 0.810 0.990 1.140

0.905 0.950 0.990 1.040 1.100 1.160 1.260 1.400 1.590 1.740

Diameter Diameter Over Over Neutral Embedded Wires Jacket (in) (in)

Total Total Ampacity w/o w/Embedded 1/C Jacket Jacket in Cable Weight Weight Tray (lb) (lb)

Ampacity Ampacity. 1/C 1/C Duct Conduit. Buried in Air

0.950 0.970 0.989 1.010 1.060 1.150 1.210

1.078 1.100 1.117 1.140 1.190 1.310 1.370

1.178 1.200 1.217 1.240 1.290 1.410 1.470

657 676 736 762 886 1038 1233

735 757 815 845 986 1141 1340

195 195 220 220 250 290 325

145 145 165 165 190 210 245

127 127 145 145 167 185 215

0.989 1.010 1.060 1.150 1.210 1.260 1.400 1.500 1.730 1.890

1.117 1.140 1.190 1.310 1.370 1.470 1.530 1.660 1.940 2.090

1.217 1.240 1.290 1.410 1.470 1.570 1.700 1.830 2.100 2.260

612 629 706 820 961 1086 1328 1681 2294 2827

698 712 806 923 1068 1229 1500 1865 2528 3072

225 225 250 275 310 335 395 445 515 560

165 165 180 205 240 260 325 390 475 525

145 145 158 180 210 228 285 342 417 460

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

311 20180401

MEDIUM VOLTAGE CABLES

Cond. Size AWG

URD 260 Mil EPR 25kV 100% LLDPE Jacket AEIC CS-8 Item #

Cond. Size AWG

Copper Neutral No.of Wires

Copper Neutral Size AWG

Conductor Diameter Diameter Diameter Over Over Insulation Insulation (in) Shield (in)

19 19 19 19 19

13 16 20 25 32

12 12 12 12 12

0.330 0.370 0.420 0.470 0.530

0.910 0.950 0.990 1.040 1.100

19 19 19 19 37 37 37

9 11 14 11 13 12 17

14 14 14 12 12 10 10

0.370 0.420 0.470 0.530 0.570 0.680 0.810

0.950 0.990 1.040 1.100 1.160 1.260 1.400

Diameter Diameter Over Over Neutral Embedded Wires Jacket (in) (in)

Total Total Ampacity w/o w/Embedded 1/C Jacket Jacket in Cable Weight Weight Tray (lb) (lb)

Ampacity Ampacity. 1/C 1/C Duct Conduit. Buried in Air

0.970 1.010 1.060 1.150 1.210

1.100 1.160 1.190 1.310 1.370

1.200 1.260 1.290 1.410 1.470

951 1107 1320 1588 1927

1032 1190 1420 1691 2034

245 280 315 360 415

185 215 240 275 315

162 189 210 241 276

1.010 1.060 1.150 1.210 1.260 1.400 1.500

1.140 1.190 1.310 1.390 1.490 1.570 1.700

1.240 1.290 1.410 1.490 1.590 1.740 1.870

896 1045 1246 1491 1724 2239 2951

996 1148 1353 1634 1896 2423 3185

275 310 345 385 410 460 520

215 250 285 320 345 405 470

189 220 250 280 303 355 412

MEDIUM VOLAGE CABLES

Full Neutral Copper Conductor 260-EPR-18 1 260-EPR-19 1/0 260-EPR-20 2/0 260-EPR-21 3/0 260-EPR-22 4/0 1/3 Neutral Copper Conductor 260-EPR-23 1/0 260-EPR-24 2/0 260-EPR-25 3/0 260-EPR-26 4/0 260-EPR-27 250 260-EPR-28 350 260-EPR-29 500

Cond. Stranding

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 311 20180401

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

URD 345 Mil EPR 35kV 100% LLDPE Jacket AEIC CS-8 Applications For use on single phase and three phase primary underground distribution systems operating at 35kV phase to phase at 100% insulation level. Suitable for either direct burial or installation in ducts. Construction Copper or aluminum concentrically stranded compressed conductor, triple single head extruded conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry nitrogen cured; solid bare copper wires uniformly spaced around the cable as a concentric neutral; LLDPE jacket with extruded longitudinal colored stripes, surface printed. Standards • AEIC CS8 Specification for Extruded Dielectric Shielded Power Cables Rated 5 through 46 kV • ICEA S-94-649 Standard for Concentric Neutral Cables Rated 5,000 - 46,000V • ICEA T-31-610 Guide for Conducting a Longitudinal Water Penetration Resistance Tests on Blocked Conductors • ICEA T-34-664 Test Method for Conducting Longitudinal Water Penetration Resistance Tests on Longitudinal Water Blocked Cables • UL-1072 MV90 Notes • Maximum conductor temperature: 90°C normal continuous, 130°C overload, 250°C short circuit.

Item #

Cond. Stranding

Full Neutral Aluminum Conductor 345-EPR-01 1/0 Solid 345-EPR-02 1/0 19 345-EPR-03 2/0 19 345-EPR-04 3/0 19 345-EPR-05 4/0 19 1/3 Neutral Aluminum Conductor 345-EPR-06 1/0 Solid 345-EPR-07 1/0 19 345-EPR-08 2/0 19 345-EPR-09 3/0 19 345-EPR-10 4/0 19 345-EPR-11 250 37 345-EPR-12 350 37 345-EPR-13 500 37 345-EPR-14 750 61 345-EPR-15 1000 61

Copper Neutral No.of Wires

Copper Neutral Size AWG

Conductor Diameter Diameter Diameter Over Over Insulation Insulation (in) Shield (in)

16 16 13 16 20

14 14 12 12 12

0.325 0.370 0.420 0.470 0.530

1.075 1.120 1.170 1.220 1.280

6 6 7 9 11 13 11 16 15 20

14 14 14 14 14 14 12 12 10 10

0.325 0.370 0.420 0.470 0.530 0.570 0.680 0.810 0.990 1.140

1.075 1.120 1.170 1.220 1.280 1.330 1.440 1.570 1.760 1.920

Diameter Diameter Over Over Neutral Embedded Wires Jacket (in) (in)

Total Total Ampacity w/o w/Embedded 1/C Jacket Jacket in Cable Weight Weight Tray (lb) (lb)

Ampacity Ampacity. 1/C 1/C Duct Conduit. Buried in Air

1.195 1.230 1.270 1.320 1.380

1.323 1.350 1.400 1.480 1.540

1.423 1.460 1.500 1.590 1.710

938 968 1105 1236 1433

1034 1068 1224 1356 1558

220 220 250 285 325

165 165 195 220 250

145 145 310 193 220

1.195 1.230 1.270 1.320 1.380 1.440 1.540 1.720 1.930 2.060

1.323 1.350 1.400 1.480 1.540 1.640 1.700 1.880 2.110 2.270

1.423 1.460 1.500 1.590 1.710 1.810 1.890 2.040 2.280 2.430

736 835 925 1018 1161 1301 1558 2003 2590 3143

815 935 1044 1138 1286 1484 1752 2213 2850 3415

215 215 245 275 305 335 390 440 515 570

165 165 190 215 245 270 320 385 475 535

145 145 167 189 215 238 280 338 417 470

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

313 20180401

MEDIUM VOLTAGE CABLES

Cond. Size AWG

URD 345 Mil EPR 35kV 100% LLDPE Jacket AEIC CS-8 Item #

Cond. Size AWG

Copper Neutral No.of Wires

Copper Neutral Size AWG

Conductor Diameter Diameter Diameter Over Over Insulation Insulation (in) Shield (in)

19 19 19 19

16 20 25 32

12 12 12 12

0.370 0.420 0.470 0.530

1.120 1.170 1.220 1.280

19 19 19 19 37 37 37 61 61

9 11 14 11 13 12 17 25 33

14 14 14 12 12 10 10 10 10

0.370 0.420 0.470 0.530 0.570 0.680 0.810 0.990 1.140

1.120 1.170 1.220 1.280 1.330 1.440 1.570 1.760 1.920

Diameter Diameter Over Over Neutral Embedded Wires Jacket (in) (in)

Total Total Ampacity w/o w/Embedded 1/C Jacket Jacket in Cable Weight Weight Tray (lb) (lb)

Ampacity Ampacity. 1/C 1/C Duct Conduit. Buried in Air

1.230 1.270 1.320 1.380

1.350 1.400 1.480 1.540

1.460 1.500 1.590 1.710

1313 1539 1786 2127

1413 1658 1906 2252

280 310 355 410

215 240 275 315

189 211 241 276

1.230 1.270 1.320 1.380 1.440 1.540 1.720 1.930 2.060

1.350 1.400 1.480 1.540 1.640 1.700 1.880 2.110 2.270

1.460 1.500 1.590 1.710 1.810 1.890 2.040 2.280 2.430

1102 1264 1444 1691 1939 2469 3273 4504 5647

1221 1384 1569 1874 2133 2679 3533 4776 5647

270 305 340 380 405 460 520 567 625

215 240 280 315 340 400 470 550 615

189 211 246 276 298 350 412 483 540

MEDIUM VOLAGE CABLES

Full Neutral Copper Conductor 345-EPR-16 1/0 345-EPR-17 2/0 345-EPR-18 3/0 345-EPR-19 4/0 1/3 Neutral Copper Conductor 345-EPR-20 1/0 345-EPR-21 2/0 345-EPR-22 3/0 345-EPR-23 4/0 345-EPR-24 250 345-EPR-25 350 345-EPR-26 500 345-EPR-27 750 345-EPR-28 1000

Cond. Stranding

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 313 20180401

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable LLDPE Jacket UL MV-90/AEIC CS8-07 Manufactured by Seoul Electric Cable Co., Ltd

Applications PowerGuard® cables are intended for use in wet or dry locations for distribution of single or three phase medium-voltage power. These cables may be installed in ducts or direct buried. Description Single conductor cable with filled strand aluminum conductors, triple extruded dry cured insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength PowerGuardTRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water blocking agents, black encapsulating linear low-density polyethylene (LLDPE) jacket.

Insulation Temperature Rating Normal.............................. 90°C Emergency*.................... 130°C Short Circuit.................... 250°C *Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during the lifetime of the cable. Specifications • ASTM B-231 • AEIC CS8 • ICEA S-94-649 • ICEA T-31-610 • ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable • UL 1072 MV-90 • CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribution Options • Copper Conductors • Black LLDPE jacket with no stripes • Multiplex cables Factory Warranty 20 Years

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

312 20160110

MEDIUM VOLTAGE CABLES

Construction Conductor: Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231. Stranded conductors are water-blocked with conductor filling compound. Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. Insulation: Extruded, Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S94-649 - 100% insulation level. Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. Metallic Shield: Solid bare copper wires helically applied and uniformly spaced. Water Block: Water-blocking agents applied over the insulation shield and around the neutral wires to resist longitudinal water penetration. Longitudinal water penetration shall be tested in accordance with the latest edition of ICEA T-34-664 except that the minimum requirement is 15 psig for 1 hour. Jacket: Black insulating sunlight resistant linear low-density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.

PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable LLDPE Jacket UL MV-90/AEIC CS8-07 Manufactured by Seoul Electric Cable Co., Ltd

MEDIUM VOLAGE CABLES

Item #

CONDUCTOR AL Size Nominal AWG or Diameter1 kcmil (in)

PHYSICAL PROPERTIES UR1C1ALW-1614DA35 1/0 UR1C1ALW-1114DA35 1/0 UR1C1ALW-0814DA35 1/0 UR1C1ALW-0614DA35 1/0 UR1C2ALW-2014DA35 2/0 UR1C2ALW-1414DA35 2/0 UR1C2ALW-1014DA35 2/0 UR1C2ALW-0714DA35 2/0 UR1C3ALW-1612DA35 3/0 UR1C3ALW-1714DA35 3/0 UR1C3ALW-1314DA35 3/0 UR1C3ALW-0914DA35 3/0 UR1C4ALW-2012DA35 4/0 UR1C4ALW-2114DA35 4/0 UR1C4ALW-1614DA35 4/0 UR1C4ALW-1114DA35 4/0 UR1C4ALW-0614DA35 4/0 UR1E5ALX-1314DA35 250 UR1E5ALX-1016DA35 250 UR1E5ALX-0616DA35 250 UR1F5ALX-1609DA35 350 UR1F5ALX-2212DA35 350 UR1F5ALX-1712DA35 350 UR1F5ALX-1814DA35 350 UR1F5ALX-0914DA35 350 UR1F5ALX-0716DA35 350 UR1H0ALX-2010DA35 500 UR1H0ALX-2412DA35 500 UR1H0ALX-1612DA35 500 UR1H0ALX-1314DA35 500 UR1H0ALX-1016DA35 500 UR1J5ALY-2310DA35 750 UR1J5ALY-2412DA35 750 UR1J5ALY-1914DA35 750 UR1J5ALY-1014DA35 750 UR1K0ALY-3010DA35 1000 UR1K0ALY-2010DA35 1000 UR1K0ALY-1612DA35 1000 UR1K0ALY-1314DA35 1000 UR1M5ALZ-2510DA35 1250 UR1M5ALZ-2012DA35 1250 UR1M5ALZ-1614DA35 1250 UR1P0ALZ-2409DA35 1500 UR1P0ALZ-2412DA35 1500 UR1P0ALZ-1914DA35 1500

0.362 0.362 0.362 0.362 0.408 0.408 0.408 0.408 0.458 0.458 0.458 0.458 0.515 0.515 0.515 0.515 0.515 0.561 0.561 0.561 0.661 0.661 0.661 0.661 0.661 0.661 0.790 0.790 0.790 0.790 0.790 0.968 0.968 0.968 0.968 1.117 1.117 1.117 1.117 1.250 1.250 1.250 1.370 1.370 1.370

INSULATION2 Minimum Maximum Diameter Diameter (in) (in)

1.045 1.045 1.045 1.045 1.090 1.090 1.090 1.090 1.140 1.140 1.140 1.140 1.195 1.195 1.195 1.195 1.195 1.250 1.250 1.250 1.355 1.355 1.355 1.355 1.355 1.355 1.480 1.480 1.480 1.480 1.480 1.670 1.670 1.670 1.670 1.815 1.815 1.815 1.815 1.960 1.960 1.960 2.100 2.100 2.100

1.145 1.145 1.145 1.145 1.190 1.190 1.190 1.190 1.240 1.240 1.240 1.240 1.295 1.295 1.295 1.295 1.295 1.350 1.350 1.350 1.455 1.455 1.455 1.455 1.455 1.455 1.580 1.580 1.580 1.580 1.580 1.770 1.770 1.770 1.770 1.920 1.920 1.920 1.920 2.065 2.065 2.065 2.205 2.205 2.205

CONCENTRIC NEUTRAL Size No. of Size of Wires Wires

Full 2/3 1/2 1/3 Full 2/3 1/2 1/3 Full 2/3 1/2 1/3 Full 2/3 1/2 1/3 1/6 1/3 1/6 1/12 Full 2/3 1/2 1/3 1/6 1/12 2/3 1/2 1/3 1/6 1/12 1/2 1/3 1/6 1/12 1/2 1/3 1/6 1/12 1/3 1/6 1/12 1/3 1/6 1/12

16 11 8 6 20 14 10 7 16 17 13 9 20 21 16 11 6 13 10 6 16 22 17 18 9 7 20 24 16 13 10 23 24 19 10 30 20 16 13 25 20 16 24 24 19

14 14 14 14 14 14 14 14 12 14 14 14 12 14 14 14 14 14 16 16 9 12 12 14 14 16 10 12 12 14 16 10 12 14 14 10 10 12 14 10 12 14 9 12 14

JACKET4 Nominal Diameter (in) (lb)

Aluminum Weight /MFT (lb)

WEIGHTS Copper Weight /MFT (lb)

Net Weight4 /MFT

1.41 1.41 1.41 1.41 1.45 1.45 1.45 1.45 1.56 1.50 1.50 1.50 1.60 1.58 1.58 1.58 1.58 1.62 1.60 1.60 1.90 1.81 1.81 1.77 1.77 1.74 1.98 1.95 1.95 1.92 1.89 2.20 2.16 2.14 2.14 2.36 2.36 2.32 2.27 2.61 2.54 2.49 2.69 2.62 2.58

99 99 99 99 125 125 125 125 157 157 157 157 198 198 198 198 198 234 234 234 328 328 328 328 328 328 469 469 469 469 469 703 703 703 703 937 937 937 937 1173 1173 1173 1408 1408 1408

209 144 104 78 266 187 133 93 332 222 170 118 415 274 209 144 78 170 84 51 667 458 354 235 117 59 662 498 332 170 84 761 498 248 133 993 660 332 173 827 415 209 1002 497 248

914 841 812 802 982 912 865 852 1190 1044 951 944 1330 1171 1126 1074 1020 1160 1069 1033 1993 1695 1603 1457 1358 1256 2181 1983 1854 1669 1629 2727 2434 2163 2076 3311 3015 2658 2455 3755 3225 2984 4036 3474 3193

1) Diameters are based on ASTM Class B Compressed diameters. 2) Extruded layer thicknesses, insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for Concentric Neutral Cables Rated 5-46kV and also meet the requirements of the latest revisions of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances. 3) Ampacity based on earth thermal resistivity of 90°C-cm/watt, 90°C conductor temperature, 20°C earth ambient temperature, 75% load factor and 36" depth of burial. Values are based on one three-phase circuit, one conductor per phase, with neutral wires bonded at each end. 4) Cables buried in flat adjacent configuration with 7.5" spacing between conductors.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 312 20160110

Information on this sheet subject to change without notice Copyright © 2018, American Wire Group, Inc.

PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable LLDPE Jacket UL MV-90/AEIC CS8-07 Manufactured by Seoul Electric Cable Co., Ltd

Item #

Pos./Neg. Seq1 Impedence (μΩ/ft) 239 + J53 238 + J53 238 + J53 238 + J53 185 + J50 185 + J50 184 + J51 184 + J51 147 + J49 146 + J49 146 + J49 145 + J49 116 + J47 115 + J47 114 + J47 114 + J47 113 + J47 96 + J46 96 + J45 95 + J45 74 + J44 72 + J44 71 + J44 70 + J44 69 + J44 68 + J44 53 + J41 51 + J42 50 + J42 49 + J42 48 + J42 39 + J38 37 + J39 35 + J40 34 + J40 32 + J35 30 + J37 27 + J38 26 + J38 26 + J36 23 + J37 21 + J37 24 + J34 21 + J35 19 + J36

TREFOIL Zero Seq1 Impedence (μΩ/ft) 414 + 475 + 528 + 568 + 331 + 384 + 440 + 497 + 264 + 315 + 357 + 419 + 209 + 253 + 291 + 351 + 442 + 308 + 423 + 446 + 131 + 157 + 184 + 235 + 346 + 417 + 109 + 129 + 166 + 258 + 370 + 87 + 115 + 188 + 288 + 66 + 87 + 145 + 236 + 70 + 118 + 199 + 60 + 100 + 174 +

J81 J126 J187 J263 J64 J94 J143 J223 J51 J74 J102 J162 J42 J58 J77 J123 J261 J100 J251 J412 J31 J37 J45 J68 J165 J367 J29 J33 J45 J96 J245 J25 J31 J58 J136 J22 J25 J42 J94 J22 J33 J71 J20 J28 J57

Ampacity1 Trefoil (amps) 217 217 217 217 250 250 251 251 286 286 286 287 328 328 329 329 330 362 362 362 429 431 433 434 436 437 522 525 530 533 536 328 637 648 656 718 735 757 772 798 837 863 855 899 934

FLAT SPACED @ 7.5” FLAT SPACED TOUCHING Pos./Neg Seq2 Zero Seq2 Ampacity2 Pos./Neg Seq3 Zero Seq3 Ampacity3. Impedence Impedence Flat Impedence Impedence Flat (μΩ/ft) (μΩ/ft) (amps) (μΩ/ft) (μΩ/ft) (amps) 255 250 246 244 204 199 195 191 168 162 159 154 139 133 129 125 119 109 102 99 95 93 90 85 77 72 74 72 68 59 53 58 56 48 42 48 48 42 35 43 39 31 39 37 29

+ J90 + J93 + J95 + J95 + J85 + J89 + J91 + J92 + J79 + J85 + J87 + J89 + J72 + J79 + J83 + J86 + J88 + J83 + J86 + J86 + J57 + J66 + J71 + J77 + J81 + J82 + J54 + J61 + J69 + J75 + J78 + J48 + J58 + J68 + J72 + J40 + J49 + J63 + J68 + J43 + J57 + J65 + J38 + J53 + J62

407 462 506 536 326 375 425 470 261 309 348 401 207 250 285 339 412 299 394 402 130 157 182 230 329 378 108 127 164 251 345 86 114 185 276 65 86 143 230 69 116 195 58 99 171

+ J84 + J130 + J191 + J262 + J67 + J98 + J148 + J225 + J53 + J78 + J106 + J167 + J43 + J60 + J81 + J128 + J261 + J105 + J251 + J394 + J32 + J38 + J47 + J71 + J170 + J355 + J29 + J34 + J47 + J101 + J247 + J26 + J32 + J61 + J142 + J22 + J26 + J44 + J99 + J22 + J34 + J74 + J20 + J29 + J60

232 233 234 235 266 268 269 271 300 303 305 307 339 343 346 350 354 381 388 391 423 427 433 445 460 468 495 497 513 544 565 568 576 620 666 635 633 678 746 671 708 793 714 734 826

240 + 239 + 238 + 237 + 187 + 185 + 185 + 184 + 149 + 147 + 147 + 146 + 119 + 117 + 116 + 114 + 113 + 97 + 96 + 99 + 77 + 75 + 74 + 72 + 70 + 69 + 56 + 54 + 52 + 50 + 48 + 42 + 40 + 37 + 35 + 35 + 33 + 30 + 27 + 30 + 30 + 23 + 27 + 24 + 21 +

J57 J58 J58 J58 J55 J55 J55 J55 J54 J53 J54 J54 J51 J52 J52 J52 J53 J51 J51 J86 J46 J48 J49 J49 J49 J49 J43 J45 J46 J47 J47 J40 J43 J44 J45 J46 J40 J42 J43 J37 J42 J42 J34 J39 J40

412 + 472 + 525 + 563 + 330 + 382 + 487 + 493 + 263 + 314 + 355 + 413 + 208 + 252 + 289 + 349 + 438 + 306 + 418 + 402 + 131 + 159 + 183 + 234 + 343 + 412 + 109 + 128 + 166 + 257 + 366 + 87 + 115 + 188 + 286 + 66 + 86 + 144 + 235 + 69 + 144 + 199 + 59 + 100 + 174 +

J81 J126 J187 J262 J64 J94 J143 J222 J52 J74 J102 J162 J42 J58 J77 J123 J260 J100 J250 J394 J31 J37 J45 J68 J165 J364 J29 J33 J45 J96 J245 J25 J31 J59 J137 J22 J25 J42 J95 J22 J42 J71 J20 J28 J57

216 217 217 217 250 250 250 251 285 285 286 286 326 327 327 328 329 361 361 391 421 427 429 431 435 436 505 511 522 530 534 592 610 638 651 659 682 727 761 720 727 836 759 821 892

1) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, in a trefoil configuration, earth rho of 90°C cm/W, earth ambient of 20°C, neutral wires grounded at both ends, 75% load factor, conductor temperature of 90°C, and 36” depth of burial. 2) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, flat spaced at 7.5” center-to-center spacing, earth rho of 90°C-cm/W, earth ambient of 20°C, neutral wires grounded at both ends, 75% load factor, conductor temperature of 90°C, and 36” depth of burial. 3) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90°C-cm/ W, earth ambient of 20°C, neutral wires grounded at both ends, 75% load factor, conductor temperature of 90°C, and 36” depth of burial.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

312 20160110

MEDIUM VOLTAGE CABLES

CONDUCTOR NEUTRAL AL Size Size AWG or kcmil ELECTRICAL PROPERTIES UR1C1ALW-1614DA35 1/0 FULL UR1C1ALW-1114DA35 1/0 2/3 UR1C1ALW-0814DA35 1/0 1/2 UR1C1ALW-0614DA35 1/0 1/3 UR1C2ALW-2014DA35 2/0 Full UR1C2ALW-1414DA35 2/0 2/3 UR1C2ALW-1014DA35 2/0 1/2 UR1C2ALW-0714DA35 2/0 1/3 UR1C3ALW-1612DA35 3/0 Full UR1C3ALW-1714DA35 3/0 2/3 UR1C3ALW-1314DA35 3/0 1/2 UR1C3ALW-0914DA35 3/0 1/3 UR1C4ALW-2012DA35 4/0 Full UR1C4ALW-2014DA35 4/0 2/3 UR1C4ALW-1614DA35 4/0 1/2 UR1C4ALW-1114DA35 4/0 1/3 UR1C4ALW-0614DA35 4/0 1/6 UR1C5ALX-1314DA35 250 1/3 UR1C5ALX-1016DA35 250 1/6 UR1C5ALX-0616DA35 250 1/12 UR1C5ALX-1609DA35 350 Full UR1C5ALX-2212DA35 350 2/3 UR1C5ALX-1712DA35 350 1/2 UR1C5ALX-1814DA35 350 1/3 UR1C5ALX-0914DA35 350 1/6 UR1C5ALX-0716DA35 350 1/12 UR1H0ALX-2010DA35 500 2/3 UR1H0ALX-2412DA35 500 1/2 UR1H0ALX-1612DA35 500 1/3 UR1H0ALX-1314DA35 500 1/6 UR1H0ALX-1016DA35 500 1/12 UR1J0ALY-2310DA35 750 1/2 UR1J0ALY-2412DA35 750 1/3 UR1J0ALY-1914DA35 750 1/6 UR1J0ALY-1014DA35 750 1/12 UR1K0ALY-3010DA35 1000 1/2 UR1K0ALY-2010DA35 1000 1/3 UR1K0ALY-1612DA35 1000 1/6 UR1K0ALY-1314DA35 1000 1/12 UR1M0ALZ-2510DA35 1250 1/3 UR1M0ALZ-2012DA35 1250 1/6 UR1M0ALZ-1614DA35 1250 1/12 UR1P0ALZ-2409DA35 1500 1/3 UR1P0ALZ-2412DA35 1500 1/6 UR1P0ALZ-1914DA35 1500 1/12

PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable LLDPE Jacket UL MV-90/AEIC CS8-07 Manufactured by Seoul Electric Cable Co., Ltd

MEDIUM VOLAGE CABLES

Item #

CONDUCTOR NEUTRAL AL Size Size AWG or or No. kcmil of Wires CONCENTRIC NEUTRAL CURRENT WITHSTAND UR1C1ALW-1614DA35 1/0 16X14 UR1C1ALW-1114DA35 1/0 11X14 UR1C1ALW-0814DA35 1/0 8X14 UR1C1ALW-0614DA35 1/0 6X14 UR1C2ALW-2014DA35 2/0 20X14 UR1C2ALW-1414DA35 2/0 14X14 UR1C2ALW-1014DA35 2/0 10X14 UR1C2ALW-0714DA35 2/0 7X14 UR1C3ALW-1612DA35 3/0 16X12 UR1C3ALW-1714DA35 3/0 17X14 UR1C3ALW-1314DA35 3/0 13X14 UR1C3ALW-0914DA35 3/0 9X14 UR1C4ALW-2012DA35 4/0 20X12 UR1C4ALW-2114DA35 4/0 21X14 UR1C4ALW-1614DA35 4/0 16X14 UR1C4ALW-1114DA35 4/0 11X14 UR1C4ALW-0614DA35 4/0 6X14 UR1E5ALX-1314DA35 250 13X14 UR1E5ALX-1016DA35 250 10x16 UR1E5ALX-0616DA35 250 6X16 UR1F5ALX-1609DA35 350 16X9 UR1F5ALX-2212DA35 350 22X12 UR1F5ALX-1712DA35 350 17X12 UR1F5ALX-1814DA35 350 18X14 UR1F5ALX-0914DA35 350 9X14 UR1F5ALX-0716DA35 350 7X16 UR1H0ALX-2010DA35 500 20X10 UR1H0ALX-2412DA35 500 24X12 UR1H0ALX-1612DA35 500 16X12 UR1H0ALX-1314DA35 500 13x14 UR1H0ALX-1016DA35 500 10x16 UR1J5ALY-2310DA35 750 23X10 UR1J5ALY-2412DA35 750 24X12 UR1J5ALY-1914DA35 750 19X14 UR1J5ALY-1014DA35 750 10X14 UR1K0ALY-3010DA35 1000 30X10 UR1K0ALY-2010DA35 1000 20X10 UR1K0ALY-1612DA35 1000 16X12 UR1K0ALY-1314DA35 1000 13X14 UR1M5ALZ-2510DA35 1250 25X10 UR1M5ALZ-2012DA35 1250 20X12 UR1M5ALZ-1614DA35 1250 16X14 UR1P0ALZ-2409DA35 1500 24X9 UR1P0ALZ-2412DA35 1500 24X12 UR1P0ALZ-1914DA35 1500 19X14

Neutral Conductor Capacitance Size Resistance (μF/Mft) 20°C μΩ/Mft Full 2/3 1/2 1/3 Full 2/3 1/2 1/3 Full 2/3 1/2 1/3 Full 2/3 1/2 1/3 1/6 1/3 1/6 1/12 Full 2/3 1/2 1/3 1/6 1/12 2/3 1/2 1/3 1/6 1/12 1/2 1/3 1/6 1/12 1/2 1/3 1/6 1/12 1/3 1/6 1/12 1/3 1/6 1/12

0.185 0.185 0.185 0.185 0.143 0.143 0.143 0.143 0.112 0.112 0.112 0.112 0.112 0.112 0.112 0.112 0.112 0.074 0.074 0.074 0.053 0.053 0.053 0.053 0.053 0.053 0.036 0.036 0.036 0.036 0.036 0.025 0.025 0.025 0.025 0.018 0.018 0.018 0.018 0.014 0.014 0.014 0.012 0.012 1.012

0.043 0.043 0.043 0.043 0.046 0.046 0.046 0.046 0.049 0.049 0.049 0.049 0.053 0.053 0.053 0.053 0.053 0.056 0.056 0.056 0.062 0.062 0.062 0.062 0.062 0.062 0.071 0.071 0.071 0.071 0.071 0.082 0.082 0.082 0.082 0.091 0.091 0.091 0.091 0.099 0.099 0.099 0.107 0.107 0.107

10 CYCLES (AMPS) Adiabatic Non Adiabatic

11570 7954 5785 4339 14462 10123 7231 5062 18300 12293 9400 6508 22875 15185 11570 7954 4339 9400 5179 2717 36369 25162 19444 13016 6508 3625 41754 27450 18300 10750 5179 41990 27450 13739 8269 62632 36513 18300 10750 45641 22875 13230 54554 27450 15711

11868 8159 5934 4451 14835 10385 7418 5192 18676 12610 9643 6676 23345 15577 11868 8159 4451 9643 5327 280 36900 25679 19843 13352 6676 3729 42349 28013 18676 10992 5327 42673 28013 14093 8456 63523 37107 18676 10992 46384 23345 13529 55350 28013 16066

20 CYCLES (AMPS) Adiabatic Non Adiabatic

8304 5709 4152 3114 10380 7266 5190 3633 13135 8823 6747 4671 16418 10899 8304 5709 3114 6747 3251 1950 26104 18060 13955 9342 4671 2275 26207 19702 13135 6747 3251 30138 19702 9861 5190 39310 26207 13135 6747 32759 16418 8304 39156 19702 9861

8602 5914 4301 3226 10752 7527 5376 3763 13510 9139 6989 4839 16887 11290 8602 5914 3226 6989 3398 2039 26634 18576 14354 9677 4839 2378 26800 2026 13510 6989 3398 30820 20265 10215 5376 40200 26800 13510 6989 33500 16887 8602 39950 20265 10215

30 CYCLES (AMPS) Adiabatic Non Adiabatic

6432 4422 3216 2412 8040 5628 4020 2814 10174 6834 5226 3618 12717 8442 6432 4422 2412 5226 2518 1511 20220 13989 10810 7236 3618 1763 20300 15261 10174 5226 2518 23345 15261 7638 4020 30450 20300 10174 5226 25375 12717 6432 30330 15261 7638

6730 4627 3365 2524 8412 5888 4206 2944 10549 7150 5468 3785 13186 8833 6730 4627 2524 5468 2665 1599 20749 14504 11208 7571 3785 1865 20892 15823 10549 5468 2665 24026 15823 7991 4206 31339 20892 10549 5468 26115 13186 6730 31124 15823 7991

1) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, in a trefoil configuration, earth rho of 90°C·cm/W, earth ambient of 20°C, neutral wires grounded at both ends, 75% load factor, conductor temperature of 90°C, and 36” depth of burial. 2) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, flat spaced at 7.5” center-to-center spacing, earth rho of 90°C·cm/W, earth ambient of 20°C, neutral wires grounded at both ends, 75% load factor, conductor temperature of 90°C, and 36” depth of burial. 3) Ampacities and impedances based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90°C·cm/ W, earth ambient of 20°C, neutral wires grounded at both ends, 75% load factor, conductor temperature of 90°C, and 36” depth of burial..

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 312 20160110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

PowerGuard® 35kV 133% MV 420 Mil TR-XLPE AL Collection System Cable LLDPE Jacket Concentric Neutral UL MV- 90/AEIC CS8-07 PHYSICAL PROPERTIES Description Single conductor cable with filled strand aluminum conductors, triple extruded dry cured insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength PowerGuard® TRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water blocking agents, black encapsulating linear low-density polyethylene (LLDPE) jacket. Design Parameters Conductor: Class B compact stranded aluminum alloy 1350 per ASTM B 231. Stranded conductors are water-blocked with conductor filling compound. Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. Insulation: Extruded, Tree-Retardant Cross-linked Polyethylene 420 Mil (TRXLPE) as defined in ANSI/ICEA S-94-649 - 133% insulation level. Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. Metallic Shield: Solid bare copper wires helically applied and uniformly spaced. Water Block: Water-blocking agents applied over the insulation shield and around the neutral wires to resist longitudinal water penetration. Longitudinal water penetration shall be tested in accordance with the latest edition of ICEA T-34-664 except that the minimum requirements are 15 psig for 1 hour. Jacket: Black insulating sunlight resistant linear low-density polyethylene encapsulating the neutral wires with three extruded red stripes and NESC lightning bolt symbol.

Specifications • ASTM B-231 • AEIC CS8 • ICEA S-94-649 • ICEA T-31-610 • ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable • UL 1072 MV-90 • CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribution Applications PowerGuard® cables are intended for use in wet or dry locations for distribution of single or three phase medium-voltage power. These cables may be installed in ducts or direct buried. Options Copper Conductors • Black LLDPE jacket with no stripes • Multiplex cables Notes 1. Diameters are based on ASTM Class B Compressed diameters. Sizes 1250 kcmil and 1500 kcmil are based on ASTM Class A Compressed diameters. 2.Extruded layer thicknesses, insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for Concentric Neutral Cables Rated 5-46kV and also meet the requirements of the latest revisions of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances. 3.Cables buried in flat adjacent configuration with 7.5"" spacing between conductors. 4.Ampacity based on earth thermal resistivity of 90 ºC-cm/watt, 90 ºC conductor temperature, 20 ºC earth ambient temperature, 75% load factor and 36"" depth of burial. Values are based on one three-phase circuit, one conductor per phase, with neutral wires bonded at each end.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

318 20160711

MEDIUM VOLTAGE CABLES

Insulation Temperature Rating Normal.............................. 90º C Emergency*......................130 ºC (*Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during the lifetime of the cable. ) Short Circuit..................... 250º C

PowerGuard® 35kV 133% MV 420 Mil TR-XLPE AL Collection System Cable LLDPE Jacket Concentric Neutral UL MV- 90/AEIC CS8-07 PHYSICAL PROPERTIES

MEDIUM VOLAGE CABLES

Item #

A1/0-01UD35UT100 A1/0-01UD35UT203 A1/0-01UD35UT102 A1/0-01UD35UT103 A2/0-01UD35UT100 A2/0-01UD35UT203 A2/0-01UD35UT102 A2/0-01UD35UT103 A3/0-01UD35UT100 A3/0-01UD35UT203 A3/0-01UD35UT102 A3/0-01UD35UT103 A4/0-01UD35UT100 A4/0-01UD35UT203 A4/0-01UD35UT102 A4/0-01UD35UT103 A4/0-01UD35UT103 A250-01UD35UT103 A250-01UD35UT106 A250-01UD35UT112 A350-01UD35UT100 A350-01UD35UT203 A350-01UD35UT102 A350-01UD35UT103 A350-01UD35UT106 A350-01UD35UT112 A500-01UD35UT203 A500-01UD35UT102 A500-01UD35UT103 A500-01UD35UT106 A750-01UD35UT102 A750-01UD35UT103 A750-01UD35UT103 A750-01UD35UT112 A1000-01UD35UT102 A1000-01UD35UT103 A1000-01UD35UT106 A1000-01UD35UT112 A1250-01UD35UT103 A1250-01UD35UT106 A1250-01UD35UT112

Conductor Size AWG or kcmil (1) 1/0 1/0 1/0 1/0 2/0 2/0 2/0 2/0 3/0 3/0 3/0 3/0 4/0 4/0 4/0 4/0 4/0 250 250 250 350 350 350 350 350 350 500 500 500 500 750 750 750 750 1000 1000 1000 1000 1250 1250 1250

Neutral Size

Full 2/3 1/2 1/3 Full 2/3 1/2 1/3 Full 2/3 1/2 1/3 Full 2/3 1/2 1/3 1/6 1/3 1/6 1/12 Full 2/3 1/2 1/3 1/6 1/12 2/3 1/2 1/3 1/6 1/2 1/3 1/6 1/12 1/2 1/3 1/6 1/12 1/3 1/6 1/12

No. ofc Wires

Size of Wires

Nominal Diameter (in) (2)

16 11 8 6 20 14 10 7 16 17 13 9 20 21 16 11 6 13 10 6 16 22 17 18 9 7 20 24 16 13 23 24 19 10 30 20 16 13 25 20 16

14 14 14 14 14 14 14 14 12 14 14 14 12 14 14 14 14 14 16 16 9 12 12 14 14 16 10 12 12 14 10 12 14 14 10 10 12 14 10 12 14

0.362 0.362 0.362 0.362 0.408 0.408 0.408 0.408 0.458 0.458 0.458 0.458 0.515 0.515 0.515 0.515 0.515 0.561 0.561 0.561 0.661 0.661 0.661 0.661 0.661 0.661 0.79 0.79 0.79 0.79 0.968 0.968 0.968 0.968 1.117 1.117 1.117 1.117 1.25 1.25 1.25

Minimal Maximum Nominal Insulation Insulation Jacket Diameter Diameter Diameter (in) (in) (in) (2) (2) (2) 1.20 1.30 1.56 1.20 1.30 1.56 1.20 1.30 1.56 1.20 1.30 1.56 1.24 1.34 1.60 1.24 1.34 1.60 1.24 1.34 1.60 1.24 1.34 1.60 1.29 1.53 1.71 1.29 1.53 1.65 1.29 1.53 1.65 1.29 1.53 1.65 1.35 1.45 1.75 1.35 1.45 1.73 1.35 1.45 1.73 1.35 1.45 1.73 1.35 1.45 1.73 1.39 1.49 1.77 1.39 1.49 1.75 1.39 1.49 1.75 1.50 1.60 2.05 1.50 1.60 1.96 1.50 1.60 1.96 1.50 1.60 1.92 1.50 1.60 1.92 1.50 1.60 1.89 1.63 1.73 2.13 1.63 1.73 2.10 1.63 1.73 2.10 1.63 1.73 2.07 1.82 1.92 2.35 1.82 1.92 2.31 1.82 1.92 2.29 1.82 1.92 2.29 1.97 2.07 2.51 1.97 2.07 2.51 1.97 2.07 2.47 1.97 2.07 2.42 2.11 2.21 2.80 2.11 2.21 2.69 2.11 2.21 2.64

Aluminum Copper Conductor Neutral (lb/MFT) (lb/MFT)

99 99 99 99 125 125 125 125 157 157 157 157 198 198 198 198 198 234 234 234 328 328 328 328 328 328 469 469 469 469 703 703 703 703 937 937 937 937 1,173 1,173 1,173

209 144 104 78 266 187 133 93 332 222 170 118 415 274 209 144 78 170 84 51 667 458 354 235 117 59 662 498 332 170 761 498 248 133 993 660 332 173 827 415 209

Total Weight (lb/MFT)

1,115 1,026 991 979 1,198 1,113 1,055 1,040 1,452 1,274 1,160 1,152 1,622 1,429 1,374 1,310 1,244 1,415 1,304 1,260 2,431 2,068 1,955 1,777 1,657 1,532 2,660 2,419 2,261 2,036 3,326 2,969 2,638 2,532 4,038 3,677 3,242 2,994 4,580 3,933 3,640

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 318 20160711

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable XLPE Jacket UL MV-105/AEIC CS8-07 Manufactured by Seoul Electric Cable Co., Ltd

Application PowerGuard®-XL cables are intended for use in wet or dry locations for distribution of single or three phase medium-voltage power. These cables may be installed in ducts or direct buried. Construction Single conductor cable with filled strand aluminum conductors, triple extruded dry cured insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength PowerGuard®-XLTRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water blocking agents, black encapsulating cross-linked polyethylene jacket. Conductor is a Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231. Stranded conductors are water-blocked with conductor filling compound. Conductor Shield is extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. Insulation is extruded, Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S-94-649 - 100% insulation level. Insulation Shield is extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. Metallic Shield is solid bare copper wires helically applied and uniformly spaced. Water-blocking agents applied over the insulation shield and around the neutral wires to resist longitudinal water penetration. Longitudinal water penetration shall be tested in accordance with the latest edition of ICEA T-34-664 except that the minimum requirement is 15 psig for 1 hour. The outer jacket is an extruded-to-fill black non-conducting cross-linked polyethylene jacket, meeting the physical requirements of Table 1 when tested by the methods specified in ANSI/ICEA S-94-649. The jacket shall be free-stripping and not interfere with an intimate contact between the neutral wires and the underlying extruded insulation shield. The jacket shall contain a print legend marking, sequential length marking and three longitudinal extruded red stripes. Factory Warranty is 20 Years. MEDIUM VOLTAGE CABLES

Options • Copper Conductors Physical Properties of Extruded-to-Fill XLPE Jacket • Unaged Tensile Strength, min. (PSI) . . .1500 • Aged* Tensile Strength, min. ret. (%) . . . .70 • Unaged Elongated, min. (%) . . . . . . . . .1500 • Aged* Elongated, min. ret. (%) . . . . . . . . .70 • Heat Distortion 1 hr at 131 ºC, max. (%) . . .3 *Aged for 168 hrs at 121 ºC Insulation Temperature Rating Normal . . . . . . . . . . . . . . . . . . . . . . . . . . . .105°C Emergency* . . . . . . . . . . . . . . . . . . . . . . .140°C Short Circuit . . . . . . . . . . . . . . . . . . . . . . .350°C *Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during the lifetime of the cable. Standards • ASTM B-231 • AEIC CS8 • ICEA S-94-649 • ICEA T-31-610 • ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable • UL 1072 MV-105 • CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribution

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

315 20160216

PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable XLPE Jacket UL MV-105/AEIC CS8-07 Manufactured by Seoul Electric Cable Co., Ltd

MEDIUM VOLAGE CABLES

Item #

PHYSICAL PROPERTIES A1/0-01UD35GT101X A1/0-01UD35GT203X A1/0-01UD35GT102X A1/0-01UD35GT103X A2/0-01UD35GT101X A2/0-01UD35GT203X A2/0-01UD35GT102X A2/0-01UD35GT103X A3/0-01UD35GT101X A3/0-01UD35GT203X A3/0-01UD35GT102X A3/0-01UD35GT103X A4/0-01UD35GT101X A4/0-01UD35GT203X A4/0-01UD35GT102X A4/0-01UD35GT103X A250-01UD35GT203X A250-01UD35GT102X A250-01UD35GT103X A250-01UD35GT106X A350-01UD35GT203X A350-01UD35GT102X A350-01UD35GT103X A350-01UD35GT106X A500-01UD35GT203X A500-01UD35GT102X A500-01UD35GT103X A500-01UD35GT106X A750-01UD35GT102X A750-01UD35GT103X A750-01UD35GT106X A750-01UD35GT112X A1000-01UD35GT102X A1000-01UD35GT103X A1000-01UD35GT106X A1000-01UD35GT112X A1250-01UD35GT103X A1250-01UD35GT106X A1250-01UD35GT112X A1500-01UD35GT103X A1500-01UD35GT106X A1500-01UD35GT112X

CONDUCTOR AL Size Nominal AWG Diameter1 or kcmil (in)

1/0 1/0 1/0 1/0 2/0 2/0 2/0 2/0 3/0 3/0 3/0 3/0 4/0 4/0 4/0 4/0 250 250 250 250 350 350 350 350 500 500 500 500 750 750 750 750 1000 1000 1000 1000 1250 1250 1250 1500 1500 1500

0.362 0.362 0.362 0.362 0.406 0.406 0.406 0.406 0.456 0.456 0.456 0.456 0.512 0.512 0.512 0.512 0.558 0.558 0.558 0.558 0.661 0.661 0.661 0.661 0.789 0.789 0.789 0.789 0.968 0.968 0.968 0.968 1.117 1.117 1.117 1.117 1.250 1.250 1.250 1.370 1.370 1.370

INSULATION1 Minimum Maximum Diameter Diameter (in) (in)

1.045 1.045 1.045 1.045 1.090 1.090 1.090 1.090 1.140 1.140 1.140 1.140 1.195 1.195 1.195 1.195 1.250 1.250 1.250 1.250 1.355 1.355 1.355 1.355 1.480 1.480 1.480 1.480 1.670 1.670 1.670 1.670 1.815 1.815 1.815 1.815 1.960 1.960 1.960 2.100 2.100 2.100

1.145 1.145 1.145 1.145 1.190 1.190 1.190 1.190 1.240 1.240 1.240 1.240 1.295 1.295 1.295 1.295 1.350 1.350 1.350 1.350 1.455 1.455 1.455 1.455 1.580 1.580 1.580 1.580 1.770 1.770 1.770 1.770 1.920 1.920 1.920 1.920 2.065 2.065 2.065 2.205 2.205 2.205

CONCENTRIC NEUTRAL Size No. Size of of Wires Wires

Full 2/3 1/2 1/3 Full 2/3 1/2 1/3 Full 2/3 1/2 1/3 Full 2/3 1/2 1/3 2/3 1/2 1/3 1/6 2/3 1/2 1/3 1/6 2/3 1/2 1/3 1/6 1/2 1/3 1/6 1/12 1/2 1/3 1/6 1/12 1/3 1/6 1/12 1/3 1/6 1/12

12 13 10 7 15 16 12 9 19 13 15 11 23 15 12 8 19 14 10 8 16 20 13 11 23 18 12 10 17 18 14 15 22 23 12 10 18 15 12 22 18 14

14 16 16 16 14 16 16 16 14 14 16 16 14 14 14 14 14 14 14 16 12 14 14 16 12 12 12 14 10 12 14 16 10 12 12 14 10 12 14 10 12 14

JACKET Nominal Diameter (in)

1.409 1.382 1.382 1.382 1.453 1.427 1.427 1.427 1.503 1.503 1.477 1.477 1.559 1.559 1.559 1.559 1.663 1.663 1.663 1.637 1.803 1.770 1.770 1.743 1.927 1.927 1.927 1.894 2.188 2.146 2.112 2.086 2.339 2.297 2.297 2.263 2.484 2.442 2.408 2.654 2.612 2.578

WEIGHTS Aluminum Copper Net Weight Weight Weight /MFT /MFT /MFT (lb) (lb) (lb) 99 99 99 99 125 125 125 125 157 157 157 157 199 199 199 199 235 235 235 235 329 329 329 329 469 469 469 469 704 704 704 704 939 939 939 939 1173 1173 1173 1408 1408 1408

153 104 80 56 192 129 96 72 243 166 120 88 294 192 153 102 243 179 128 64 325 256 166 88 467 366 244 128 549 366 179 120 711 467 244 128 582 305 153 711 366 179

946 869 850 831 1038 948 923 904 1151 1090 1013 987 1278 1196 1166 1125 1404 1353 1312 1216 1718 1602 1530 1420 2083 2001 1904 1746 2709 2468 2246 2142 3226 2931 2752 2581 3513 3185 2952 4081 3691 3454

AMPACITY DIRECT BURIED Flat2 Tre-Foil3

216 217 217 217 250 250 250 251 285 285 286 286 326 327 327 328 360 361 361 362 427 429 431 435 505 511 522 530 592 610 638 651 659 682 727 761 720 727 836 759 821 892

217 217 217 217 250 250 251 251 266 286 286 287 328 328 329 329 362 362 363 363 431 433 434 436 522 525 530 533 628 637 648 656 718 735 757 772 798 837 863 855 899 934

1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for concentric neutral cables rated 5-46 kV and also meet the requirements of the latest revisions of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances. 2) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90ºC-cm/ W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% load factor, conductor temperature of 105ºC, and 36" depth of burial. 3) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90 ºC-cm/W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% load factor, conductor temperature of 105ºC, and 36" depth of burial. 4) UL Type MV-105 PowerGuard®-XL is rated MV-105 in accordance with the UL 1072 Standard. It should be noted that utilizing a 105 ºC normal operating conductor temperature will increase cable ampacity rating but will reduce the shield fault capability slightly. If the user plans on operating these cables at 105ºC conductor temperature for normal operation and 140ºC for emergency overload, please contact American Wire Group for the applicable cable ampacity and shield fault capability ratings. Another important consideration is that the migration of soil moisture away from the cable is more likely at the higher operating conductor temperature and can result in an increase in soil thermal resistivity, resulting in an increase in conductor and soil temperature.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 315 20160216

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable XLPE Jacket UL MV-105/AEIC CS8-07 Manufactured by Seoul Electric Cable Co., Ltd

Item #

TREFOIL Zero Seq1 Impedence (μΩ/ft) 477 + 543 + 580 + 605 + 386 + 455 + 501 + 535 + 311 + 369 + 425 + 472 + 252 + 311 + 347 + 414 + 260 + 307 + 362 + 448 + 196 + 225 + 291 + 390 + 137 + 160 + 209 + 310 + 110 + 146 + 240 + 306 + 84 + 114 + 186 + 286 + 92 + 152 + 251 + 78 + 131 + 226 +

117J 189J 258J 371J 90J 147J 211J 294J 68J 106J 159J 234J 55J 86J 114J 192J 66J 95J 147J 329J 48J 61J 104J 233J 34J 41J 63J 143J 30J 40J 90J 154J 25J 31J 61J 142J 26J 46J 111J 23J 38J 91J

Ampacity1 Trefoil (amps) 233 234 234 234 269 269 270 270 307 308 308 308 352 353 353 354 354 389 389 389 463 465 466 469 561 564 569 573 674 685 698 705 770 790 815 831 857 901 930 918 969 1008

FLAT SPACED @ 7.5” FLAT SPACED TOUCHING Pos./Neg Seq2 Zero Seq2 Ampacity2 Pos./Neg Seq3 Zero Seq3 Ampacity3. Impedence Impedence Flat Impedence Impedence Flat (μΩ/ft) (μΩ/ft) (amps) (μΩ/ft) (μΩ/ft) (amps) 261 257 255 252 208 203 200 197 170 165 161 158 139 133 130 126 118 113 110 104 92 89 84 78 74 71 66 59 58 54 46 42 50 47 39 33 42 36 29 40 34 27

+ 93J + 95J + 95J + 96J + 89J + 91J + 92J + 93J + 84J + 87J + 89J + 90J + 78J + 84J + 85J + 87J + 80J + 82J + 84J + 86J + 73J + 76J + 80J + 82J + 62J + 67J + 73J + 77J + 56J + 64J + 71J + 73J + 48J + 57J + 66J + 69J + 52J + 62J + 66J + 46J + 58J + 64J

463 519 547 560 377 437 475 499 305 358 406 443 248 303 336 392 255 297 346 410 193 221 281 364 136 159 205 296 109 145 234 292 84 113 183 274 92 151 243 77 130 220

+ 121J + 192J + 257J + 358J + 93J + 151J + 213J + 289J + 71J + 110J + 163J + 234J + 57J + 90J + 118J + 195J + 69J + 99J + 151J + 321J + 51J + 64J + 108J + 234J + 35J + 43J + 66J + 147J + 30J + 41J + 95J + 159J + 25J + 32J + 64J + 147J + 27J + 48J + 116J + 24J + 39J + 95J

250 251 252 253 286 288 290 292 323 327 329 331 366 369 373 377 382 411 418 421 466 472 481 496 546 550 564 589 633 642 685 722 711 712 759 823 759 801 886 809 836 931

249 + 249 + 248 + 248 + 194 + 193 + 192 + 192 + 154 + 153 + 152 + 145 + 122 + 120 + 120 + 119 + 103 + 102 + 101 + 100 + 76 + 75 + 74 + 72 + 56 + 55 + 53 + 51 + 42 + 40 + 37 + 36 + 35 + 32 + 29 + 27 + 29 + 25 + 23 + 27 + 23 + 20 +

57J 58J 58J 58J 56J 55J 55J 56J 54J 54J 54J 54J 52J 52J 52J 52J 50J 51J 51J 51J 49J 49J 49J 50J 45J 46J 47J 47J 42J 44J 45J 45J 39J 42J 43J 43J 40J 42J 42J 38J 40J 40J

473 + 538 + 574 + 598 + 384 + 451 + 497 + 530 + 309 + 366 + 421 + 456 + 250 + 309 + 345 + 410 + 259 + 304 + 359 + 442 + 194 + 224 + 289 + 386 + 137 + 159 + 239 + 307 + 110 + 145 + 239 + 303 + 84 + 114 + 185 + 283 + 92 + 153 + 249 + 78 + 131 + 224 +

117J 189J 257J 369J 90J 147J 210J 292J 68J 106J 159J 224J 55J 86J 114J 192J 66J 95J 146J 327J 49J 61J 104J 232J 34J 41J 90J 142J 30J 40J 90J 154J 25J 31J 61J 142J 27J 46J 111J 23J 38J 91J

233 234 234 234 269 269 270 270 307 307 308 308 351 352 353 354 355 388 389 390 459 462 464 468 552 556 563 571 659 671 689 702 748 766 797 821 823 797 912 876 931 982

1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for concentric neutral cables rated 5-46 kV and also meet the requirements of the latest revisions of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances. 2) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90ºC-cm/ W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% load factor, conductor temperature of 105ºC, and 36" depth of burial. 3) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90 ºC-cm/W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% load factor, conductor temperature of 105ºC, and 36" depth of burial. 4) UL Type MV-105 PowerGuard®-XL is rated MV-105 in accordance with the UL 1072 Standard. It should be noted that utilizing a 105 ºC normal operating conductor temperature will increase cable ampacity rating but will reduce the shield fault capability slightly. If the user plans on operating these cables at 105ºC conductor temperature for normal operation and 140ºC for emergency overload, please contact American Wire Group for the applicable cable ampacity and shield fault capability ratings. Another important consideration is that the migration of soil moisture away from the cable is more likely at the higher operating conductor temperature and can result in an increase in soil thermal resistivity, resulting in an increase in conductor and soil temperature.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

315 20160216

MEDIUM VOLTAGE CABLES

CONDUCTOR NEUTRAL AL Size Size Pos./Neg. Seq1 AWG or Impedence kcmil (μΩ/ft) ELECTRICAL PROPERTIES A1/0-01UD35GT101X 1/0 Full 250 + 53J A1/0-01UD35GT203X 1/0 2/3 249 + 53J A1/0-01UD35GT102X 1/0 1/2 249 + 53J A1/0-01UD35GT103X 1/0 1/3 249 + 53J A2/0-01UD35GT101X 2/0 Full 193 + 50J A2/0-01UD35GT203X 2/0 2/3 193 + 50J A2/0-01UD35GT102X 2/0 1/2 193 + 50J A2/0-01UD35GT103X 2/0 1/3 192 + 50J A3/0-01UD35GT101X 3/0 Full 153 + 49J A3/0-01UD35GT203X 3/0 2/3 152 + 49J A3/0-01UD35GT102X 3/0 1/2 152 + 49J A3/0-01UD35GT103X 3/0 1/3 152 + 49J A4/0-01UD35GT101X 4/0 Full 120 + 47J A4/0-01UD35GT203X 4/0 2/3 119 + 47J A4/0-01UD35GT102X 4/0 1/2 119 + 47J A4/0-01UD35GT103X 4/0 1/3 119 + 47J A250-01UD35GT203X 250 2/3 102 + 46J A250-01UD35GT102X 250 1/2 101 + 46J A250-01UD35GT103X 250 1/3 101 + 46J A250-01UD35GT106X 250 1/6 100 + 45J A350-01UD35GT203X 350 2/3 74 + 44J A350-01UD35GT102X 350 1/2 73 + 44J A350-01UD35GT103X 350 1/3 73 + 44J A350-01UD35GT106X 350 1/6 72 + 44J A500-01UD35GT203X 500 2/3 53 + 41J A500-01UD35GT102X 500 1/2 53 + 42J A500-01UD35GT103X 500 1/3 51 + 42J A500-01UD35GT106X 500 1/6 50 + 42J A750-01UD35GT102X 750 1/2 39 + 39J A750-01UD35GT103X 750 1/3 37 + 40J A750-01UD35GT106X 750 1/6 36 + 40J A750-01UD35GT112X 750 1/12 35 + 40J A1000-01UD35GT102X 1000 1/2 31 + 37J A1000-01UD35GT103X 1000 1/3 29 + 37J A1000-01UD35GT106X 1000 1/6 27 + 38J A1000-01UD35GT112X 1000 1/12 26 + 38J A1250-01UD35GT103X 1250 1/3 25 + 37J A1250-01UD35GT106X 1250 1/6 23 + 37J A1250-01UD35GT112X 1250 1/12 22 + 37J A1500-01UD35GT103X 1500 1/3 23 + 35J A1500-01UD35GT106X 1500 1/6 20 + 36J A1500-01UD35GT112X 1500 1/12 19 + 36J

PowerGuard® 35kV 100% MV TR-XLPE Aluminum Collection System Cable XLPE Jacket UL MV-105/AEIC CS8-07 Manufactured by Seoul Electric Cable Co., Ltd

MEDIUM VOLAGE CABLES

Item #

CURRENT WITHSTAND A1/0-01UD35GT101X A1/0-01UD35GT203X A1/0-01UD35GT102X A1/0-01UD35GT103X A2/0-01UD35GT101X A2/0-01UD35GT203X A2/0-01UD35GT102X A2/0-01UD35GT103X A3/0-01UD35GT101X A3/0-01UD35GT203X A3/0-01UD35GT102X A3/0-01UD35GT103X A4/0-01UD35GT101X A4/0-01UD35GT203X A4/0-01UD35GT102X A4/0-01UD35GT103X A250-01UD35GT203X A250-01UD35GT102X A250-01UD35GT103X A250-01UD35GT106X A350-01UD35GT203X A350-01UD35GT102X A350-01UD35GT103X A350-01UD35GT106X A500-01UD35GT203X A500-01UD35GT102X A500-01UD35GT103X A500-01UD35GT106X A750-01UD35GT102X A750-01UD35GT103X A750-01UD35GT106X A750-01UD35GT112X A1000-01UD35GT102X A1000-01UD35GT103X A1000-01UD35GT106X A1000-01UD35GT112X A1250-01UD35GT103X A1250-01UD35GT106X A1250-01UD35GT112X A1500-01UD35GT103X A1500-01UD35GT106X A1500-01UD35GT112X

Conductor AL Size AWG or kcmil

Neutral Size

Conductor Resistance 20°C μΩ/Mft

Capacitance (μF/Mft)

1/0 1/0 1/0 1/0 2/0 2/0 2/0 2/0 3/0 3/0 3/0 3/0 4/0 4/0 4/0 4/0 250 250 250 250 350 350 350 350 500 500 500 500 750 750 750 750 1000 1000 1000 1000 1250 1250 1250 1500 1500 1500

Full 2/3 1/2 1/3 Full 2/3 1/2 1/3 Full 2/3 1/2 1/3 Full 2/3 1/2 1/3 2/3 1/2 1/3 1/6 2/3 1/2 1/3 1/6 2/3 1/2 1/3 1/6 1/2 1/3 1/6 1/12 1/2 1/3 1/6 1/12 1/3 1/6 1/12 1/3 1/6 1/12

0.1850 0.1850 0.1850 0.1850 0.1430 0.1430 0.1430 0.1430 0.1130 0.1130 0.1130 0.1130 0.0880 0.0880 0.0880 0.0880 0.0740 0.0740 0.0740 0.0740 0.0530 0.0530 0.0530 0.0530 0.0360 0.0360 0.0360 0.0360 0.0250 0.0250 0.0250 0.0250 0.0180 0.0180 0.0180 0.0180 0.0140 0.0140 0.0140 0.0120 0.0120 0.0120

0.0430 0.0430 0.0430 0.0430 0.0465 0.0465 0.0465 0.0465 0.0494 0.0494 0.0494 0.0494 0.0531 0.0531 0.0531 0.0531 0.0560 0.0560 0.0560 0.0560 0.0624 0.0624 0.0624 0.0624 0.0706 0.0706 0.0706 0.0706 0.0818 0.0818 0.0818 0.0818 0.0912 0.0912 0.0912 0.0912 0.0995 0.0995 0.0995 0.1069 0.1069 0.1069

10 CYCLES (AMPS) Adiabatic Non Adiabatic

8173 5540 4261 2983 10217 6818 5114 3835 12892 8855 6392 4688 15606 10217 8173 5617 13289 9499 6811 3413 17237 13571 9127 4688 24798 19392 12928 6811 29234 19392 9536 6392 37833 24798 12928 6811 31907 16160 8173 38883 19392 9829

8384 5720 4400 3080 10480 7040 5280 3960 13225 9083 6600 4840 16010 10480 8384 5757 13622 9745 6987 3524 17591 13921 9356 4840 25307 19790 13194 6987 29710 19790 9782 6600 38448 25307 13194 6987 32410 16492 8384 39497 19790 10075

20 CYCLES (AMPS) Adiabatic Non Adiabatic

5866 3976 3059 2141 7333 4894 3670 2753 9253 6355 4588 3364 11201 7333 5866 3911 9253 6818 4889 2450 12372 9740 6355 3364 17799 13919 9279 4889 20983 13919 6844 4588 27154 17799 9279 4889 22217 11599 5866 27074 13919 6844

6077 4156 3197 2238 7596 5115 3837 2877 9586 6583 4796 3517 11604 7596 6077 4051 9586 7063 5064 2560 12725 10090 6583 3517 18307 14316 9544 5064 21458 14316 7090 4796 27769 18307 9544 5064 22720 11930 6077 27688 14316 7090

30 CYCLES (AMPS) Adiabatic Non Adiabatic

4544 3080 2369 1658 5680 3791 2843 2132 7167 4923 3554 2606 8676 5680 4544 3029 7167 5281 3787 1897 9583 7545 4923 2606 13787 10781 7188 3787 16253 10781 5301 3554 21033 13787 7188 3787 17209 8984 4544 20972 10781 5301

4754 3260 2507 1755 5943 4012 3009 2257 7499 5150 3761 2758 9078 5943 4754 3169 7499 5526 3962 2008 9936 7894 5150 2758 14294 11178 7452 3962 16728 11178 5547 3761 21647 14294 7452 3962 17712 9315 4754 21585 11178 5547

1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for concentric neutral cables rated 5-46 kV and also meet the requirements of the latest revisions of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances. 2) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90ºC-cm/ W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% load factor, conductor temperature of 105ºC, and 36" depth of burial. 3) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90 ºC-cm/W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% load factor, conductor temperature of 105ºC, and 36" depth of burial. 4) UL Type MV-105 PowerGuard®-XL is rated MV-105 in accordance with the UL 1072 Standard. It should be noted that utilizing a 105 ºC normal operating conductor temperature will increase cable ampacity rating but will reduce the shield fault capability slightly. If the user plans on operating these cables at 105ºC conductor temperature for normal operation and 140ºC for emergency overload, please contact American Wire Group for the applicable cable ampacity and shield fault capability ratings. Another important consideration is that the migration of soil moisture away from the cable is more likely at the higher operating conductor temperature and can result in an increase in soil thermal resistivity, resulting in an increase in conductor and soil temperature.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 315 2010216

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

PowerGuard® 15kV 133% MV TR-XLPE Aluminum Collection System Cable XLPE Jacket UL MV-105/AEIC CS8-07 Applications PowerGuard® XL cables are intended for use in wet or dry locations for distribution of single or three phase medium-voltage power. These cables may be installed in ducts or direct buried. Description Single conductor cable with filled strand aluminum conductors, triple extruded dry cured insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength PowerGuard XLTRXLPE insulation, thermosetting semiconducting insulation shield, copper concentric neutral wires, water blocking agents, black encapsulating cross-linked polyethylene jacket.

Physical Properties of Extruded-to-Fill XLPE Jacket Unaged Tensile Strength, min. (PSI) 1500 Aged* Tensile Strength, min. ret. (%) 70 Unaged Elongated, min. (%) 1500 Aged* Elongated, min. ret. (%) 70 Heat Distortion 1 hr at 131°C, max. (%) 30 *Aged for 168 hrs at 121°C

Insulation Temperature Rating Normal Emergency* Short Circuit

105°C 140°C 250°C

* Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during the lifetime of the cable.

Specifications • ASTM B-231 • AEIC CS8 • ICEA S-94-649 • ICEA T-31-610 • ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable • UL-1072 MV-105 Options • Copper Conductors

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

320 20161021

MEDIUM VOLTAGE CABLES

Construction Conductor: Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231. Stranded conductors are water-blocked with conductor filling compound. Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation. Insulation: Extruded, unfilled Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S-94-649 - 133% insulation level. Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. Metallic Shield: Solid bare copper wires helically applied and uniformly spaced. Water Block: Water-blocking agents applied over the insulation shield and around the neutral wires to resist longitudinal water penetration. Longitudinal water penetration shall be tested in accordance with the latest edition of ICEA T-34-664 except that the minimum requirement is 15 psig for 1 hour. Jacket: The outer jacket is an extruded-to-fill black non-conducting cross-linked polyethylene jacket, meeting the physical requirements of Table 1 when tested by the methods specified in ANSI/ICEA S94-649. The jacket shall be free-stripping and not interfere with an intimate contact between the neutral wires and the underlying extruded insulation shield. The jacket shall contain a print legend marking, sequential length marking and three longitudinal extruded red stripes. Factory Warranty: 20 Years

PowerGuard® 15kV 133% MV TR-XLPE Aluminum Collection System Cable XLPE Jacket UL MV-105/AEIC CS8-07

MEDIUM VOLAGE CABLES

Item #

A1/0-01UD15UT100X A1/0-01UD15UT203X A1/0-01UD15UT102X A1/0-01UD15UT103X A2/0-01UD15UT100X A2/0-01UD15UT203X A2/0-01UD15UT102X A2/0-01UD15UT103X A3/0-01UD15UT100X A3/0-01UD15UT203X A3/0-01UD15UT102X A3/0-01UD15UT103X A4/0-01UD15UT100X A4/0-01UD15UT203X A4/0-01UD15UT102X A4/0-01UD15UT103X A250-01UD15UT203X A250-01UD15UT102X A250-01UD15UT103X A250-01UD15UT106X A350-01UD15UT203X A350-01UD15UT102X A350-01UD15UT103X A350-01UD15UT106X A500-01UD15UT203X A500-01UD15UT102X A500-01UD15UT103X A500-01UD15UT106X A750-01UD15UT102X A750-01UD15UT103X A750-01UD15UT106X A750-01UD15UT112X A1000-01UD15UT102X A1000-01UD15UT103X A1000-01UD15UT106X A1000-01UD15UT112X A1250-01UD15UT103X A1250-01UD15UT106X A1250-01UD15UT112X

Conductor Neutral Neutral Neutral TRXLPE TRXLPE TRXLPE1 Encap XLPE Size No. of Nominal Size No. of Size Insulation1 Insulation1 Insulation Jacket1 AWG/ Wires Diameter AWG/ Wires Nominal Minimum Maximum Nominal kcmil (in) kcmil (mil) Thickness Diameter Diameter Thickness (mil) (in) (in) (mil) 1/0 19 0.362 14 12 Full 0.220 0.805 0.895 0.055 1/0 19 0.362 16 13 2/3 0.220 0.805 0.895 0.055 1/0 19 0.362 16 10 1/2 0.220 0.805 0.895 0.055 1/0 19 0.362 16 7 1/3 0.220 0.805 0.895 0.055 2/0 19 0.406 14 15 Full 0.220 0.850 0.940 0.055 2/0 19 0.406 16 16 2/3 0.220 0.850 0.940 0.055 2/0 19 0.406 16 12 1/2 0.220 0.850 0.940 0.055 2/0 19 0.406 16 9 1/3 0.220 0.850 0.940 0.055 3/0 19 0.456 14 19 Full 0.220 0.900 0.990 0.055 3/0 19 0.456 14 13 2/3 0.220 0.900 0.990 0.055 3/0 19 0.456 16 15 1/2 0.220 0.900 0.990 0.055 3/0 19 0.456 16 11 1/3 0.220 0.900 0.990 0.055 4/0 19 0.512 14 23 Full 0.220 0.955 1.045 0.055 4/0 19 0.512 14 15 2/3 0.220 0.955 1.045 0.055 4/0 19 0.512 14 12 1/2 0.220 0.955 1.045 0.055 4/0 19 0.512 14 8 1/3 0.220 0.955 1.045 0.055 250 37 0.558 14 19 2/3 0.220 1.010 1.100 0.080 250 37 0.558 14 14 1/2 0.220 1.010 1.100 0.080 250 37 0.558 14 10 1/3 0.220 1.010 1.100 0.080 250 37 0.558 16 8 1/6 0.220 1.010 1.100 0.080 350 37 0.661 12 16 2/3 0.220 1.115 1.205 0.080 350 37 0.661 14 20 1/2 0.220 1.115 1.205 0.080 350 37 0.661 14 13 1/3 0.220 1.115 1.205 0.080 350 37 0.661 16 11 1/6 0.220 1.115 1.205 0.080 500 37 0.789 12 23 2/3 0.220 1.240 1.330 0.080 500 37 0.789 12 18 1/2 0.220 1.240 1.330 0.080 500 37 0.789 12 12 1/3 0.220 1.240 1.330 0.080 500 37 0.789 14 10 1/6 0.220 1.240 1.330 0.080 750 61 0.968 10 17 1/2 0.220 1.430 1.520 0.080 750 61 0.968 12 18 1/3 0.220 1.430 1.520 0.080 750 61 0.968 14 14 1/6 0.220 1.430 1.520 0.080 750 61 0.968 16 15 1/12 0.220 1.430 1.520 0.080 1000 61 1.117 10 22 1/2 0.220 1.575 1.670 0.080 1000 61 1.117 12 23 1/3 0.220 1.575 1.670 0.080 1000 61 1.117 12 12 1/6 0.220 1.575 1.670 0.080 1000 61 1.117 14 10 1/12 0.220 1.575 1.670 0.080 1250 61 1.25 10 18 1/3 0.220 1.720 1.815 0.080 1250 61 1.25 12 15 1/6 0.220 1.720 1.815 0.080 1250 61 1.25 14 12 1/12 0.220 1.720 1.815 0.080

Encap XLPE Aprox Weight Ampacity Direct Buried Jacket1 Conductor Neutral Net Flat2 Tre-Foil3 Nominal (lbs/MFT) (lbs/MFT) (lbs/MFT) Diameter (in) 1.159 99 153 718 216 217 1.132 99 104 647 217 217 1.132 99 80 628 217 217 1.132 99 56 609 217 217 1.203 125 192 803 250 250 1.177 125 129 720 250 250 1.177 125 96 694 250 251 1.177 125 72 675 251 251 1.253 157 243 908 285 286 1.253 157 166 846 285 286 1.227 157 120 776 286 286 1.227 157 88 750 286 287 1.309 199 294 1026 326 328 1.309 199 192 944 327 328 1.309 199 153 914 327 329 1.309 199 102 873 328 329 1.413 235 243 1131 360 362 1.413 235 179 1080 361 362 1.413 235 128 1039 361 363 1.387 235 64 950 362 363 1.553 329 325 1420 427 431 1.520 329 256 1312 429 433 1.520 329 166 1240 431 434 1.493 329 88 1137 435 436 1.677 469 467 1765 505 522 1.677 469 366 1684 511 525 1.677 469 244 1586 522 530 1.644 469 128 1437 530 533 1.938 704 549 2344 592 628 1.896 704 366 2115 610 637 1.862 704 179 1901 638 648 1.836 704 120 1804 651 656 2.089 939 711 2838 659 718 2.047 939 467 2554 682 735 2.047 939 244 2375 727 757 2.013 939 128 2213 761 772 2.234 1173 582 3102 720 798 2.192 1173 305 2786 727 837 2.158 1173 153 2590 836 863

1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-94-649 for concentric neutral cables rated 5-46 kV and also meet the requirements of the latest revisions of AEIC CS8. Dimensions and weights not designated as minimum or maximum are nominal values and are subject to manufacturing tolerances. 2) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90ºC-cm/ W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% load factor, conductor temperature of 105ºC, and 36" depth of burial. 3) Ampacities based on cables operating in a 3-phase installation with one cable per phase, flat spaced and touching, earth rho of 90 ºC-cm/W, earth ambient of 20ºC, neutral wires grounded at both ends, 75% load factor, conductor temperature of 105ºC, and 36" depth of burial. 4) UL Type MV-105 PowerGuard®-XL is rated MV-105 in accordance with the UL 1072 Standard. It should be noted that utilizing a 105 ºC normal operating conductor temperature will increase cable ampacity rating but will reduce the shield fault capability slightly. If the user plans on operating these cables at 105ºC conductor temperature for normal operation and 140ºC for emergency overload, please contact Classic Wire and Cable, LLC for the applicable cable ampacity and shield fault capability ratings. Another important consideration is that the migration of soil moisture away from the cable is more likely at the higher operating conductor temperature and can result in an increase in soil thermal resistivity, resulting in an increase in conductor and soil temperature.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 320 20161021

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

PowerGuard® 5kV-35kV Aluminum TR-XLPE Tape Shield PVC Jacket UL MV-105/AEIC CS8-07 Manufactured by Seoul Electric Cable Co., Ltd

Applications PowerGuard cables are intended for use in wet or dry locations for distribution of single or three phase medium-voltage power. These cables may be installed in ducts or direct buried. Construction Cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over an aluminum conductor and cured in a single operation. Uncoated copper tape (helically applied) and overlaying black PVC jacket are applied over the cable core. The conductor Class B compressed concentric lay, filled stranded 1350 aluminum. Conductor shield is an extruded semi-conducting thermosetting polymeric stress control layer. Insulation is extruded, TRXLPE (TreeRetardant Cross-linked Polyethylene). Insulation shield is an extruded semi-conducting thermosetting layer, clean and free-stripping from insulation. The metallic shield is flat uncoated 5-mil-thick copper tape helically applied with minimum 25% overlap. The jacket is sunlight and moisture resistant black, non-conducting PVC (Polyvinyl Chloride).

Standards • ANSI/ICEA S-97-682 • UL-1072 MV-105 • AEIC CS8 as applicable for TRXLPE (Tree-Retardant Cross-linked Polyethylene) insulated shielded power cable • ICEA T-31-610 • CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribution Temperature Rating Normal..............................105°C Emergency*.................... 140°C Short Circuit.................... 250°C *Operation at the emergency overload temperature shall not exceed 1500 hours cumulative during the lifetime of the cable. Options • Copper conductors • CPE (chlorinated polyethylene) Jacket conforming to the requirements specified for chlorinated polyethylene jackets in ICEA. The average thickness shall be in accordance with Table 4-3 of ICEA and the minimum spot thickness shall be not less than 80% of the average thickness • Non-filled conductor • Compact strand conductor For information on conductor sizes or voltage ratings not shown in the tables, contact your AWG sales representative or email: [email protected].

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

314 20160110

MEDIUM VOLTAGE CABLES

Features • Triple-extruded for clean interfaces • Dry nitrogen cure for enhanced performance • Class 10,000 environment utilized for material handling • Excellent moisture resistance • High dielectric strength • Low dielectric loss • Excellent resistance to treeing • Clean-stripping insulation shield • Sunlight and moisture resistant • Approved for CT use 1/0 and larger

PowerGuard® 5kV-35kV Aluminum TR-XLPE Tape Shield PVC Jacket UL MV-105/AEIC CS8-07 Manufactured by Seoul Electric Cable Co., Ltd

MEDIUM VOLAGE CABLES

Item #

Compressed Nominal Diameter Diameter Diameter Conductor Insulation Insulation Insulation 5 mil CU Aluminum Thickness Min Max Tape Size/No of Wires (mil) (in)1 (in)1 (in)1

115 Mils TRXLPE 5kV 133% OR 8kV 100% A2-01MV5UT10501 2/7 A1/0-01MV5UT10501 1/0 / 19 A2/0-01MV5UT10501 2/0 / 19 A3/0-01MV5UT10501 3/0 / 19 A4/0-01MV5UT10501 4/0 / 19 A250-01MV5UT10501 250 / 37 A350-01MV5UT10501 350 / 37 A500-01MV5UT10501 500 / 37 A750-01MV5UT10501 750 / 61 A1000-01MV5UT10501 1000 / 61 175 Mils TRXLPE 15kV 100% A2-01MV15GT10501 2/7 A1-01MV15GT10501 1 / 19 A1/0-01MV15GT10501 1/0 / 19 A2/0-01MV15GT10501 2/0 / 19 A3/0-01MV15GT10501 3/0 / 19 A4/0-01MV15GT10501 4/0 / 19 A250-01MV15GT10501 250 / 37 A350-01MV15GT10501 350 / 37 A500-01MV15GT10501 500 / 37 A750-01MV15GT10501 750 / 61 A1000-01MV15GT1051 1000 / 61 220 Mils TRXLPE 15kV 133% A2-01MV15UT10501 2/7 A1-01MV15UT10501 1 / 19 A1/0-01MV15UT10501 1/0 / 19 A2/0-01MV15UT10501 2/0 / 19 A3/0-01MV15UT10501 3/0 / 19 A4/0-01MV15UT10501 4/0 / 19 A250-01MV15UT10501 250 / 37 A350-01MV15UT10501 350 / 37 A500-01MV15UT10501 500 / 37 A750-01MV15UT10501 750 / 61 A1000-01MV15UT1051 1000 / 61

Diameter Nominal PVC Jacket Jacket Thickness (in)1 (in)1

Approx. Weight AL (lb/Mft)1

Approx. Weight CU (lb/Mft)1

Approx. Weight Total (lb/Mft)1

Ampacity2 Ampacity2 Direct in Duct Buried

115 115 115 115 115 115 115 115 115 115

0.525 0.605 0.65 0.7 0.755 0.81 0.905 1.04 1.23 1.375

0.605 0.685 0.725 0.775 0.835 0.89 0.98 1.12 1.31 1.46

0.621 0.7 0.744 0.794 0.85 0.906 1.009 1.137 1.324 1.473

0.75 0.829 0.903 0.953 1.009 1.065 1.168 1.296 1.483 1.632

0.065 0.065 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08

62 99 125 158 199 234 329 468 703 937

44 49 53 56 60 64 71 81 94 104

289 357 426 482 549 640 754 954 1279 1584

165 215 245 280 320 350 425 520 655 760

125 165 185 210 240 275 330 405 510 610

175 175 175 175 175 175 175 175 175 175 175

0.635 0.675 0.715 0.76 0.81 0.865 0.92 1.015 1.15 1.34 1.485

0.72 0.76 0.8 0.845 0.895 0.95 1.005 1.1 1.235 1.425 1.575

0.741 0.78 0.82 0.864 0.914 0.97 1.026 1.129 1.257 1.444 1.593

0.87 0.939 0.979 1.023 1.073 1.129 1.185 1.288 1.416 1.603 1.812

0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.11

62 78 99 125 158 199 234 329 468 703 937

52 55 58 61 65 69 73 80 89 102 113

364 422 463 513 572 643 710 861 1070 1410 1822

165 190 215 245 280 320 350 425 520 655 760

125 145 165 185 210 240 275 330 405 510 610

220 220 220 220 220 220 220 220 220 220 220

0.725 0.765 0.805 0.85 0.9 0.955 1.01 1.105 1.24 1.43 1.575

0.815 0.855 0.895 0.935 0.985 1.045 1.1 1.19 1.33 1.52 1.67

0.831 0.87 0.91 0.954 1.004 1.06 1.116 1.219 1.347 1.534 1.683

0.99 1.029 1.069 1.113 1.163 1.219 1.275 1.378 1.506 1.693 1.902

0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.11

62 78 99 125 158 199 234 329 468 703 937

59 62 64 68 71 75 79 86 96 109 119

451 488 532 584 646 720 790 947 1163 1513 1939

165 190 215 245 280 320 350 425 520 650 760

125 145 165 185 210 240 275 330 405 510 610

(1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-97-682 for shielded power cables rated 5-46 kV and also meet the requirements of the latest revisions of AEIC CS8. (2) Ampacity based on earth thermal resistivity of 90˚C-cm/watt, 105˚C conductor temp., 20˚C earth ambient temperature, 75% load factor and 36" depth of burial. Values are based on one three-phase circuit, one conductor per phase, in flat adjacent configuration (direct buried) with metallic shield bonded at each end. Dimensions and weights not designated minimum or maximum are nominal values and subject to manufacturing tolerances. In this context, weight means mass.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 314 20160110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

PowerGuard® 5kV-35kV Aluminum TR-XLPE Tape Shield PVC Jacket UL MV-105/AEIC CS8-07 Manufactured by Seoul Electric Cable Co., Ltd

Item #

Compressed Nominal Diameter Diameter Diameter Conductor Insulation Insulation Insulation 5 mil CU Aluminum Thickness Min Max Tape Size/No of Wires (mil) (in)1 (in)1 (in)1

Approx. Weight AL (lb/Mft)1

Approx. Weight CU (lb/Mft)1

Approx. Weight Total (lb/Mft)1

Ampacity2 Ampacity2 Direct in Duct Buried

1 / 19 1/0 / 19 2/0 / 19 3/0 / 19 4/0 / 19 250 / 37 350 / 37 500 / 37 750 / 61 1000 / 61

260 260 260 260 260 260 260 260 260 260

0.835 0.875 0.92 0.97 1.025 1.08 1.175 1.31 1.5 1.645

0.925 0.965 1.01 1.06 1.115 1.175 1.265 1.405 1.595 1.74

0.95 0.99 1.034 1.084 1.14 1.196 1.299 1.427 1.614 1.763

1.109 1.149 1.193 1.243 1.299 1.355 1.458 1.586 1.833 1.982

0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.11 0.11

78 99 125 158 199 234 329 468 703 937

67 70 73 77 81 85 92 101 115 125

551 597 651 716 793 866 1027 1250 1707 2047

185 215 245 275 315 350 420 515 650 755

145 165 185 215 250 275 335 405 520 605

1/0 / 19 2/0 / 19 3/0 / 19 4/0 / 19 250 / 37 350 / 37 500 / 37 750 / 61 1000 / 61

345 345 345 345 345 345 345 345 345

1.045 1.09 1.14 1.195 1.25 1.345 1.48 1.67 1.815

1.145 1.119 1.24 1.295 1.35 1.445 1.58 1.77 1.92

1.16 1.204 1.254 1.31 1.366 1.469 1.597 1.784 1.933

1.319 1.363 1.413 1.469 1.525 1.628 1.816 2.003 2.152

0.08 0.08 0.08 0.08 0.08 0.08 0.11 0.11 0.11

99 125 158 199 234 329 468 703 937

82 85 89 93 97 104 113 127 137

748 807 877 960 1039 1212 1544 1934 2290

210 240 275 310 345 415 510 640 745

170 190 220 250 275 340 410 525 615

1/0 / 19 2/0 / 19 3/0 / 19 4/0 / 19 250 / 37 350 / 37 500 / 37 750 / 61 1000 / 61

420 420 420 420 420 420 420 420 420

1.198 1.242 1.292 1.348 1.394 1.497 1.625 1.816 1.965

1.318 1.362 1.412 1.468 1.514 1.617 1.745 1.936 2.085

1.318 1.362 1.412 1.468 1.514 1.617 1.745 1.936 2.085

1.478 1.522 1.572 1.628 1.674 1.777 1.965 2.156 2.305

0.08 0.08 0.08 0.08 0.08 0.08 0.11 0.11 0.11

99 125 158 199 234 329 468 703 937

92 95 99 104 108 116 126 142 153

967 1032 1109 1200 1381 1598 1865 2284 2666

210 240 275 310 345 415 510 640 745

170 190 220 250 275 340 410 525 615

(1) Extruded layer thicknesses and insulation and insulation shield diameters are in accordance with ANSI/ICEA S-97-682 for shielded power cables rated 5-46 kV and also meet the requirements of the latest revisions of AEIC CS8. (2) Ampacity based on earth thermal resistivity of 90˚C-cm/watt, 105˚C conductor temp., 20˚C earth ambient temperature, 75% load factor and 36" depth of burial. Values are based on one three-phase circuit, one conductor per phase, in flat adjacent configuration (direct buried) with metallic shield bonded at each end. Dimensions and weights not designated minimum or maximum are nominal values and subject to manufacturing tolerances. In this context, weight means mass.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

314 20160110

MEDIUM VOLTAGE CABLES

260 Mils TRXLPE 25kV 100% A1-01MV25GT10501 A1/0-01MV25GT10501 A2/0-01MV25GT10501 A3/0-01MV25GT10501 A4/0-01MV25GT10501 A250-01MV25GT10501 A350-01MV25GT10501 A500-01MV25GT10501 A750-01MV25GT10501 A1000-01MV25GT1051 345 Mils TRXLPE 35kV 100% A1/0-01MV35GT10501 A2/0-01MV35GT10501 A3/0-01MV35GT10501 A4/0-01MV35GT10501 A250-01MV35GT10501 A350-01MV35GT10501 A500-01MV35GT10501 A750-01MV35GT10501 A1000-01MV35GT1051 420 Mils TRXLPE 35kV 133% A1/0-01MV35UT10501 A2/0-01MV35UT10501 A3/0-01MV35UT10501 A4/0-01MV35UT10501 A250-01MV35UT10501 A350-01MV35UT10501 A500-01MV35UT10501 A750-01MV35UT10501 A1000-01MV35UT1051

Diameter Nominal PVC Jacket Jacket Thickness (in)1 (in)1

MEDIUM VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

PowerGuard® 5kV-35kV Copper 3-Conductor TR-XLPE Tape Shield w/Ground PVC Jacket UL MV-105/AEIC CS8-07 Applications Medium voltage power cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods. Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not more than six feet apart. Installed in both exposed and concealed work, wet or dry locations, directly buried. Construction Conductor: Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231. Stranded conductors are water-blocked with conductor filling compound. Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation Insulation: Extruded, Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S94-649 Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. Metallic Shield:The metallic shield is flat uncoated 5-mil thick copper tape helically applied with minimum 20% overlap. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w/Red, 1C w/Blue, and 1C w/None. Grounding Conductors: Three bare stranded copper conductor, one in each interstice. Fillers: Non hydroscopic fillers, forming a firm and cylindrical cable core. Binder Tape: A binder tape is applied to maintain core symmetry and mechanical stability. Jacket: Black, sunlight resistant, flame retardant PVC jacket tightly applied over the binder tape.

NOTES: Ampacities are based on three phase operation In Duct (2011 NEC Table 310.15(B)(80): Three-conductor cable in plastic duct, direct-buried, 90°C conductor temperature, 20°C ambient temperature, earth RHO of 90°C-cm/Watt, and 100% load factor, and shields short-circuited. Isolated in Air (2011 NEC Table 310.15(B)(72)): Three-conductor cable, 90°C conductor temperature, and 40°C ambient temperature, and shields grounded at one point only. In Cable Tray: Per 2011 NEC 392.80(B)(1)(b), for single conductor cables, sizes 1/0 AWG and larger, installed in a single layer in an uncovered table tray, with a maintained space of not less than one cable diameter between individual conductors, the ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table 310.15(B)(72) (Aluminum), “Isolated in Air” values noted above.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

316 20150519

MEDIUM VOLTAGE CABLES

Standards • AEIC CS8, Specifications for Shielded Power Cable, 5-46kV • ICEA S-93-639, 5-46 kV Shielded Power Cable • ICEA S-97-682, Utility Shielded Power Cable Rated 5-46 kV • UL 1072 MV-105 • IEEE- IEEE 383 Flame Test • For 105°C continuous, 140°C emergency, 250°C short-circuit operation. • CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribution

PowerGuard® 5kV-35kV Copper 3-Conductor TR-XLPE Tape Shield w/Ground PVC Jacket UL MV-105/AEIC CS8-07

MEDIUM VOLAGE CABLES

Item #

Size Insulation No. of Size of Conductor Insulation Insulation AWG Thickness Ground Ground Diameter Diameter Shield or (mil) Wires Wires (in) (in) (in) KCMIL

Overall Jacket (in)

Approx. Weight (lb/MFT)

Minimum Ampacity Bending 90°C Radius in Duct (in)

Ampacity 90°C in Air

5kV Copper 100% 4-03MV5GT10501 4 2-03MV5GT10501 2 1-03MV5GT10501 1 1/0-03MV5GT10501 1/0 2/0-03MV5GT10501 2/0 3/0-03MV5GT10501 3/0 4/0-03MV5GT10501 4/0 250-03MV5GT10501 250 350-03MV5GT10501 350 500-03MV5GT10501 500 750-03MV5GT10501 750 1000-03MV5GT10501 1000 5kV Copper 133% 4-03MV5UT10501 4 2-03MV5UT10501 2 1-03MV5UT10501 1 1/0-03MV5UT10501 1/0 2/0-03MV5UT10501 2/0 3/0-03MV5UT10501 3/0 4/0-03MV5UT10501 4/0 250-03MV5UT10501 250 350-03MV5UT10501 350 500-03MV5UT10501 500 750-03MV5UT10501 750 1000-03MV5UT10501 1000

90 90 90 90 90 90 90 90 90 90 90 90

3 3 3 3 3 3 3 3 3 3 3 3

10 10 8 8 8 7 7 7 6 5 4 4

0.226 0.284 0.324 0.364 0.408 0.458 0.515 0.561 0.664 0.794 0.974 1.124

0.45 0.51 0.55 0.59 0.64 0.69 0.74 0.8 0.9 1.03 1.22 1.37

0.51 0.57 0.61 0.65 0.69 0.74 0.8 0.85 0.95 1.1 1.29 1.44

1.32 1.44 1.53 1.61 1.71 1.88 2 2.11 2.34 2.65 3.12 3.44

1097 1412 1682 1948 2271 2812 3317 3761 4918 6668 9629 12287

10 11 11 12 12 14 15 15 17 19 22 25

100 135 155 175 200 230 265 290 355 430 530 600

105 140 160 185 215 250 285 320 395 485 615 705

115 115 115 115 115 115 115 115 115 115 115 115

3 3 3 3 3 3 3 3 3 3 3 3

10 10 8 8 8 7 7 7 6 5 4 4

0.226 0.284 0.324 0.364 0.408 0.458 0.515 0.561 0.664 0.794 0.974 1.124

0.5 0.56 0.6 0.64 0.69 0.74 0.79 0.85 0.95 1.08 1.27 1.42

0.56 0.62 0.66 0.7 0.74 0.79 0.85 0.9 1 1.15 1.34 1.49

1.42 1.55 1.64 1.78 1.88 1.99 2.11 2.22 2.44 2.76 3.22 3.55

1193 1515 1789 2158 2493 2941 3453 3903 5072 6839 9829 12504

10 11 12 13 14 14 15 16 18 20 23 25

100 135 155 175 200 230 265 290 355 430 530 600

105 140 160 185 215 250 285 320 395 485 615 705

8kV Copper 100% 4-03MV8GT10501 2-03MV8GT10501 1-03MV8GT10501 1/0-03MV8GT10501 2/0-03MV8GT10501 3/0-03MV8GT10501 4/0-03MV8GT10501 250-03MV8GT10501 350-03MV8GT10501 500-03MV8GT10501 750-03MV8GT10501 1000-03MV8GT10501

115 115 115 115 115 115 115 115 115 115 115 115

3 3 3 3 3 3 3 3 3 3 3 3

10 10 8 8 8 7 7 7 6 5 4 4

0.226 0.284 0.324 0.364 0.408 0.458 0.515 0.561 0.664 0.794 0.974 1.124

0.5 0.56 0.6 0.64 0.69 0.74 0.79 0.85 0.95 1.08 1.27 1.42

0.56 0.62 0.66 0.7 0.74 0.79 0.85 0.9 1 1.15 1.34 1.49

1.42 1.55 1.64 1.78 1.88 1.99 2.11 2.22 2.44 2.76 3.22 3.55

1193 1515 1789 2158 2493 2941 3453 3903 5072 6839 9829 12504

10 11 12 13 14 14 15 16 18 20 23 25

115 150 170 195 220 250 285 310 375 450 545 615

120 165 185 215 245 285 325 360 435 535 670 770

4 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 316 20150519

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

PowerGuard® 5kV-35kV Copper 3-Conductor TR-XLPE Tape Shield w/Ground PVC Jacket UL MV-105/AEIC CS8-07 Item #

8kV Copper 133% 2-03MV8UT10501 1-03MV8UT10501 1/0-03MV8UT10501 2/0-03MV8UT10501 3/0-03MV8UT10501 4/0-03MV8UT10501 250-03MV8UT10501 350-03MV8UT10501 500-03MV8UT10501 750-03MV8UT10501 1000-03MV8UT10501

Overall Jacket (in)

Approx. Weight (lb/MFT)

Minimum Ampacity Bending 90°C Radius in Duct (in)

Ampacity 90°C in Air

2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

140 140 140 140 140 140 140 140 140 140 140

3 3 3 3 3 3 3 3 3 3 3

10 8 8 8 7 7 7 6 5 4 4

0.284 0.324 0.364 0.408 0.458 0.515 0.561 0.664 0.794 0.974 1.124

0.61 0.65 0.69 0.74 0.79 0.84 0.9 1 1.13 1.32 1.47

0.67 0.71 0.75 0.79 0.84 0.9 0.95 1.05 1.2 1.39 1.54

1.66 1.8 1.89 1.99 2.09 2.22 2.33 2.55 2.93 3.33 3.66

1623 2002 2282 2622 3076 3594 4051 5232 7180 10034 12728

12 13 14 14 15 16 17 18 21 24 26

150 170 195 220 250 285 310 375 450 545 615

165 185 215 245 285 325 360 435 535 670 770

2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

175 175 175 175 175 175 175 175 175 175 175

3 3 3 3 3 3 3 3 3 3 3

10 8 8 8 7 7 7 6 5 4 4

0.284 0.324 0.364 0.408 0.458 0.515 0.561 0.664 0.794 0.974 1.124

0.68 0.72 0.76 0.81 0.86 0.91 0.97 1.07 1.2 1.39 1.54

0.74 0.78 0.82 0.86 0.91 0.97 1.02 1.14 1.27 1.46 1.62

1.87 1.96 2.04 2.14 2.24 2.37 2.48 2.74 3.08 3.48 3.84

1888 2179 2466 2813 3275 3803 4268 5529 7447 10333 13138

14 14 15 15 16 17 18 20 22 25 27

150 170 195 220 250 285 310 375 450 545 615

165 185 215 245 285 325 360 435 535 670 770

2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

220 220 220 220 220 220 220 220 220 220 220

3 3 3 3 3 3 3 3 3 3 3

10 8 8 8 7 7 7 6 5 4 4

0.284 0.324 0.364 0.408 0.458 0.515 0.561 0.664 0.794 0.974 1.124

0.77 0.81 0.85 0.9 0.95 1 1.06 1.16 1.29 1.48 1.63

0.83 0.87 0.91 0.95 1 1.06 1.13 1.23 1.36 1.55 1.71

2.06 2.15 2.24 2.33 2.44 2.56 2.71 2.99 3.27 3.68 4.04

2124 2424 2719 3075 3548 4088 4627 6018 7808 10733 13574

15 16 16 17 18 18 19 21 23 26 29

150 170 195 220 250 285 310 375 450 545 615

165 185 215 245 285 325 360 435 535 670 770

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

316 20150519

MEDIUM VOLTAGE CABLES

15kV Copper 100% 2-03MV15GT10501 1-03MV15GT10501 1/0-03MV15GT10501 2/0-03MV15GT10501 3/0-03MV15GT10501 4/0-03MV15GT10501 250-03MV15GT10501 350-03MV15GT10501 500-03MV15GT10501 750-03MV15GT10501 1000-03MV15GT10501 15kV Copper 133% 2-03MV15UT10501 1-03MV15UT10501 1/0-03MV15UT10501 2/0-03MV15UT10501 3/0-03MV15UT10501 4/0-03MV15UT10501 250-03MV15UT10501 350-03MV15UT10501 500-03MV15UT10501 750-03MV15UT10501 1000-03MV15UT10501

Size Insulation No. of Size of Conductor Insulation Insulation AWG Thickness Ground Ground Diameter Diameter Shield or (mil) Wires Wires (in) (in) (in) KCMIL

PowerGuard® 5kV-35kV Copper 3-Conductor TR-XLPE Tape Shield w/Ground PVC Jacket UL MV-105/AEIC CS8-07

MEDIUM VOLAGE CABLES

Item #

25kV Copper 100% 1-03MV25GT10501 1/0-03MV25GT10501 2/0-03MV25GT10501 3/0-03MV25GT10501 4/0-03MV25GT10501 250-03MV25GT10501 350-03MV25GT10501 500-03MV25GT10501 750-03MV25GT10501 1000-03MV25GT10501 25kV Copper 133% 1/0-03MV25UT10501 2/0-03MV25UT10501 3/0-03MV25UT10501 4/0-03MV25UT10501 250-03MV25UT10501 350-03MV25UT10501 500-03MV25UT10501 35kV Copper 100% 1/0-03MV35GT10501 2/0-03MV35GT10501 3/0-03MV35GT10501 4/0-03MV35GT10501 250-03MV35GT10501 350-03MV35GT10501 500-03MV35GT10501 35kV Copper 133% 1/0-03MV35UT10501 2/0-03MV35UT10501 3/0-03MV35UT10501 4/0-03MV35UT10501 250-03MV35UT10501 350-03MV35UT10501 500-03MV35UT10501

Size Insulation No. of Size of Conductor Insulation Insulation AWG Thickness Ground Ground Diameter Diameter Shield or (mil) Wires Wires (in) (in) (in) KCMIL

Overall Jacket (in)

Approx. Weight (lb/MFT)

Minimum Ampacity Bending 90°C Radius in Duct (in)

Ampacity 90°C in Air

1 1/0 2/0 3/0 4/0 250 350 500 750 1000

260 260 260 260 260 260 260 260 260 260

3 3 3 3 3 3 3 3 3 3

8 8 8 7 7 7 6 5 4 4

0.324 0.364 0.408 0.458 0.515 0.561 0.664 0.794 0.974 1.124

0.89 0.93 0.98 1.03 1.08 1.14 1.24 1.37 1.56 1.71

0.95 0.99 1.03 1.1 1.16 1.21 1.31 1.44 1.64 1.79

2.32 2.41 2.5 2.65 2.77 2.94 3.16 3.45 3.89 4.21

2657 2960 3324 3868 4421 5073 6330 8144 11193 13978

17 17 18 19 20 21 23 25 28 30

170 195 220 250 285 310 375 450 545 615

185 215 245 285 325 360 435 535 670 770

1/0 2/0 3/0 4/0 250 350 500

345 345 345 345 345 345 345

3 3 3 3 3 3 3

8 8 7 7 7 6 5

0.364 0.408 0.458 0.515 0.561 0.664 0.794

1.11 1.15 1.2 1.26 1.31 1.41 1.54

1.18 1.22 1.27 1.33 1.38 1.48 1.63

2.88 2.97 3.08 3.21 3.32 3.54 3.86

3761 4151 4662 5245 5762 7060 9015

21 21 22 23 24 25 27

195 220 250 285 310 375 450

215 245 285 325 360 435 535

1/0 2/0 3/0 4/0 250 350 500

345 345 345 345 345 345 345

3 3 3 3 3 3 3

8 8 7 7 7 6 5

0.364 0.408 0.458 0.515 0.561 0.664 0.794

1.11 1.15 1.2 1.26 1.31 1.41 1.54

1.18 1.22 1.27 1.33 1.38 1.48 1.63

2.88 2.97 3.08 3.21 3.32 3.54 3.86

3761 4151 4662 5245 5762 7060 9015

21 21 22 23 24 25 27

195 220 250 285 310 375 450

215 245 285 325 360 435 535

1/0 2/0 3/0 4/0 250 350 500

420 420 420 420 420 420 420

3 3 3 3 3 3 3

8 8 7 7 7 6 5

0.364 0.408 0.458 0.515 0.561 0.664 0.794

1.26 1.3 1.35 1.41 1.46 1.57 1.7

1.33 1.38 1.43 1.48 1.54 1.65 1.78

3.21 3.31 3.41 3.54 3.65 3.91 4.19

4356 4761 5291 5895 6430 7854 9775

23 24 24 25 26 28 30

195 220 250 285 310 375 450

215 245 285 325 360 435 535

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 316 20150519

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

PowerGuard® 5kV-35kV Aluminum 3-Conductor TR-XLPE Tape Shield w/Ground PVC Jacket UL MV-105/AEIC CS8-07 Applications Medium-Voltage power cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods. Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not more than six feet apart. Installed in both exposed and concealed work, wet or dry locations, directly buried. Construction Conductor: Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231. Stranded conductors are water-blocked with conductor filling compound. Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation Insulation: Extruded, Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S94-649 Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. Metallic Shield:The metallic shield is flat uncoated 5-mil thick copper tape helically applied with minimum 20% overlap. A Mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w/Red, 1C w/Blue, and 1C w/None. Grounding Conductors: Three bare stranded copper conductor, one in each interstice. Fillers: Non hydroscopic fillers, forming a firm and cylindrical cable core. Binder Tape: A binder tape is applied to maintain core symmetry and mechanical stability. Jacket: Black, sunlight resistant, flame retardant PVC jacket tightly applied over the binder tape.

NOTES: Ampacities are based on three Phase Operation In Duct (2011 NEC Table 310.15(B)(80): Three-conductor cable in plastic duct, direct-buried, 90°C conductor temperature, 20°C ambient temperature, earth RHO of 90°C-cm/Watt, and 100% load factor, and shields short-circuited. Isolated in Air (2011 NEC Table 310.15(B)(72)): Three-conductor cable, 90°C conductor temperature, and 40°C ambient temperature, and shields grounded at one point only. In Cable Tray: Per 2011 NEC 392.80(B)(1)(b), for single conductor cables, sizes 1/0 AWG and larger, installed in a single layer in an uncovered table tray, with a maintained space of not less than one cable diameter between individual conductors, the ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table 310.15(B)(72) (Aluminum), “Isolated in Air” values noted above.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

317 20150519

MEDIUM VOLTAGE CABLES

Standards • AEIC CS8, Specifications for Shielded Power Cable, 5-46kV • ICEA S-93-639, 5-46 kV Shielded Power Cable • ICEA S-97-682, Utility Shielded Power Cable Rated 5-46 kV • UL 1072 MV-105 • IEEE- IEEE 383 Flame Test • For 105°C continuous, 140°C emergency, 250°C short-circuit operation. • CSA Standard C68.5-07 File # 257759 Primary Shielded and Concentric Neutral Cable for Distribution

PowerGuard® 5kV-35kV Aluminum 3-Conductor TR-XLPE Tape Shield w/Ground PVC Jacket UL MV-105/AEIC CS8-07

MEDIUM VOLAGE CABLES

Item #

5kV Aluminum 100% A4-03MV5GT10501 A2-03MV5GT10501 A1-03MV5GT10501 A1/0-03MV5GT10501 A2/0-03MV5GT10501 A3/0-03MV5GT10501 A4/0-03MV5GT10501 A250-03MV5GT10501 A350-03MV5GT10501 A500-03MV5GT10501 A750-03MV5GT10501 A1000-03MV5GT10501 5kV Aluminum 133% A4-03MV5UT10501 A2-03MV5UT10501 A1-03MV5UT10501 A1/0-03MV5UT10501 A2/0-03MV5UT10501 A3/0-03MV5UT10501 A4/0-03MV5UT10501 A250-03MV5UT10501 A350-03MV5UT10501 A500-03MV5UT10501 A750-03MV5UT10501 A1000-03MV5UT10501 8kV Aluminum 100% A4-03MV8GT10501 A2-03MV8GT10501 A1-03MV8GT10501 A1/0-03MV8GT10501 A2/0-03MV8GT10501 A3/0-03MV8GT10501 A4/0-03MV8GT10501 A250-03MV8GT10501 A350-03MV8GT10501 A500-03MV8GT10501 A750-03MV8GT10501 A1000-03MV8GT10501

Size Insulation No. of Size of Conductor Insulation Insulation AWG Thickness Ground Ground Diameter Diameter Shield or (mil) Wires Wires (in) (in) (in) KCMIL

Overall Jacket (in)

Approx. Weight (lb/MFT)

Minimum Ampacity Bending 90°C Radius in Duct (in)

Ampacity 90°C in Air

4 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

90 90 90 90 90 90 90 90 90 90 90 90

3 3 3 3 3 3 3 3 3 3 3 3

10 10 10 10 8 8 8 8 7 6 5 4

0.226 0.284 0.324 0.364 0.408 0.458 0.515 0.561 0.664 0.794 0.974 1.124

0.45 0.51 0.55 0.59 0.64 0.69 0.74 0.8 0.9 1.03 1.22 1.37

0.51 0.57 0.61 0.65 0.69 0.74 0.8 0.85 0.95 1.1 1.29 1.44

1.32 1.44 1.53 1.61 1.77 1.88 2 2.11 2.34 2.65 3.12 3.44

833 993 1093 1218 1522 1705 1930 2131 2643 3424 4755 5886

10 11 11 12 13 14 15 15 17 19 22 25

80 105 120 140 160 180 205 230 280 340 425 495

81 110 125 145 170 195 225 250 310 385 495 585

4 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

115 115 115 115 115 115 115 115 115 115 115 115

3 3 3 3 3 3 3 3 3 3 3 3

10 10 10 10 8 8 8 8 7 6 5 4

0.226 0.284 0.324 0.364 0.408 0.458 0.515 0.561 0.664 0.794 0.974 1.124

0.5 0.56 0.6 0.64 0.69 0.74 0.79 0.85 0.95 1.08 1.27 1.42

0.56 0.62 0.66 0.7 0.74 0.79 0.85 0.9 1 1.15 1.34 1.49

1.42 1.55 1.64 1.78 1.88 1.99 2.11 2.22 2.44 2.76 3.22 3.55

929 1095 1200 1429 1645 1834 2066 2273 2797 3595 4955 6103

10 11 12 13 14 14 15 16 18 20 23 25

80 105 120 140 160 180 205 230 280 340 425 495

81 110 125 145 170 195 225 250 310 385 495 585

4 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

115 115 115 115 115 115 115 115 115 115 115 115

3 3 3 3 3 3 3 3 3 3 3 3

10 10 10 10 8 8 8 8 7 6 5 4

0.226 0.284 0.324 0.364 0.408 0.458 0.515 0.561 0.664 0.794 0.974 1.124

0.5 0.56 0.6 0.64 0.69 0.74 0.79 0.85 0.95 1.08 1.27 1.42

0.56 0.62 0.66 0.7 0.74 0.79 0.85 0.9 1 1.15 1.34 1.49

1.42 1.55 1.64 1.78 1.88 1.99 2.11 2.22 2.44 2.76 3.22 3.55

929 1095 1200 1429 1645 1834 2066 2273 2797 3595 4955 6103

10 11 12 13 14 14 15 16 18 20 23 25

89 115 135 150 170 195 220 245 295 355 440 510

95 125 145 170 190 220 255 280 345 425 540 635

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 317 20150519

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

PowerGuard® 5kV-35kV Aluminum 3-Conductor TR-XLPE Tape Shield w/Ground PVC Jacket UL MV-105/AEIC CS8-07 Item #

8kV Aluminum 133% A2-03MV8UT10501 A1-03MV8UT10501 A1/0-03MV8UT10501 A2/0-03MV8UT10501 A3/0-03MV8UT10501 A4/0-03MV8UT10501 A250-03MV8UT10501 A350-03MV8UT10501 A500-03MV8UT10501 A750-03MV8UT10501 A1000-03MV8UT10501

Size Insulation No. of Size of Conductor Insulation Insulation AWG Thickness Ground Ground Diameter Diameter Shield or (mil) Wires Wires (in) (in) (in) KCMIL 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

Approx. Weight (lb/MFT)

Minimum Ampacity Bending 90°C Radius in Duct (in)

Ampacity 90°C in Air

140 140 140 140 140 140 140 140 140 140 140

3 3 3 3 3 3 3 3 3 3 3

10 10 10 8 8 8 8 7 6 5 4

0.284 0.324 0.364 0.408 0.458 0.515 0.561 0.664 0.794 0.974 1.124

0.61 0.65 0.69 0.74 0.79 0.84 0.9 1 1.13 1.32 1.47

0.67 0.71 0.75 0.79 0.84 0.9 0.95 1.05 1.2 1.39 1.54

1.66 1.8 1.89 1.99 2.09 2.22 2.33 2.55 2.93 3.33 3.66

1204 1413 1553 1774 1969 2208 2421 2957 3936 5161 6327

12 13 14 14 15 16 17 18 21 24 26

115 135 150 170 195 220 245 295 355 440 510

125 145 170 190 220 255 280 345 425 540 635

175 175 175 175 175 175 175 175 175 175 175

3 3 3 3 3 3 3 3 3 3 3

10 10 10 8 8 8 8 7 6 5 4

0.284 0.324 0.364 0.408 0.458 0.515 0.561 0.664 0.794 0.974 1.124

0.68 0.72 0.76 0.81 0.86 0.91 0.97 1.07 1.2 1.39 1.54

0.74 0.78 0.82 0.86 0.91 0.97 1.02 1.14 1.27 1.46 1.62

1.87 1.96 2.04 2.14 2.24 2.37 2.48 2.74 3.08 3.48 3.84

1469 1590 1736 1965 2168 2416 2638 3254 4203 5459 6737

14 14 15 15 16 17 18 20 22 25 27

115 135 150 170 195 220 245 295 355 440 510

125 145 170 190 220 255 280 345 425 540 635

220 220 220 220 220 220 220 220 220 220 220

3 3 3 3 3 3 3 3 3 3 3

10 10 10 8 8 8 8 7 6 5 4

0.284 0.324 0.364 0.408 0.458 0.515 0.561 0.664 0.794 0.974 1.124

0.77 0.81 0.85 0.9 0.95 1 1.06 1.16 1.29 1.48 1.63

0.83 0.87 0.91 0.95 1 1.06 1.13 1.23 1.36 1.55 1.71

2.06 2.15 2.24 2.33 2.44 2.56 2.71 2.99 3.27 3.68 4.04

1705 1834 1989 2227 2441 2701 2997 3743 4564 5859 7173

15 16 16 17 18 18 19 21 23 26 29

115 135 150 170 195 220 245 295 355 440 510

125 145 170 190 220 255 280 345 425 540 635

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

317 20150519

MEDIUM VOLTAGE CABLES

15kV Aluminum 100% A2-03MV15GT10501 2 A1-03MV15GT10501 1 A1/0-03MV15GT10501 1/0 A2/0-03MV15GT10501 2/0 A3/0-03MV15GT10501 3/0 A4/0-03MV15GT10501 4/0 A250-03MV15GT10501 250 A350-03MV15GT10501 350 A500-03MV15GT10501 500 A750-03MV15GT10501 750 A1000-03MV15GT10501 1000 15kV Aluminum 133% A2-03MV15UT10501 2 A1-03MV15UT10501 1 A1/0-03MV15UT10501 1/0 A2/0-03MV15UT10501 2/0 A3/0-03MV15UT10501 3/0 A4/0-03MV15UT10501 4/0 A250-03MV15UT10501 250 A350-03MV15UT10501 350 A500-03MV15UT10501 500 A750-03MV15UT10501 750 A1000-03MV15UT10501 1000

Overall Jacket (in)

PowerGuard® 5kV-35kV Aluminum 3-Conductor TR-XLPE Tape Shield w/Ground PVC Jacket UL MV-105/AEIC CS8-07

MEDIUM VOLAGE CABLES

Item #

Size Insulation No. of Size of Conductor Insulation Insulation AWG Thickness Ground Ground Diameter Diameter Shield or (mil) Wires Wires (in) (in) (in) KCMIL

25kV Aluminum 100% A1-03MV25GT10501 1 A1/0-03MV25GT10501 1/0 A2/0-03MV25GT10501 2/0 A3/0-03MV25GT10501 3/0 A4/0-03MV25GT10501 4/0 A250-03MV25GT10501 250 A350-03MV25GT10501 350 A500-03MV25GT10501 500 A750-03MV25GT10501 750 A1000-03MV25GT10501 1000 25kV Aluminum 133% A1/0-03MV25UT10501 1/0 A2/0-03MV25UT10501 2/0 A3/0-03MV25UT10501 3/0 A4/0-03MV25UT10501 4/0 A250-03MV25UT10501 250 A350-03MV25UT10501 350 A500-03MV25UT10501 500 35kV Aluminum 100% A1/0-03MV35GT10501 1/0 A2/0-03MV35GT10501 2/0 A3/0-03MV35GT10501 3/0 A4/0-03MV35GT10501 4/0 A250-03MV35GT10501 250 A350-03MV35GT10501 350 A500-03MV35GT10501 500 35kV Aluminum 133% A1/0-03MV35UT10501 1/0 A2/0-03MV35UT10501 2/0 A3/0-03MV35UT10501 3/0 A4/0-03MV35UT10501 4/0 A250-03MV35UT10501 250 A350-03MV35UT10501 350 A500-03MV35UT10501 500

Overall Jacket (in)

Approx. Weight (lb/MFT)

Minimum Ampacity Bending 90°C Radius in Duct (in)

Ampacity 90°C in Air

260 260 260 260 260 260 260 260 260 260

3 3 3 3 3 3 3 3 3 3

10 10 8 8 8 8 7 6 5 4

0.324 0.364 0.408 0.458 0.515 0.561 0.664 0.794 0.974 1.124

0.89 0.93 0.98 1.03 1.08 1.14 1.24 1.37 1.56 1.71

0.95 0.99 1.03 1.1 1.16 1.21 1.31 1.44 1.64 1.79

2.32 2.41 2.5 2.65 2.77 2.94 3.16 3.45 3.89 4.21

2068 2230 2476 2761 3034 3444 4055 4900 6319 7577

17 17 18 19 20 21 23 25 28 30

135 150 170 195 220 245 295 355 440 510

145 170 190 220 255 280 345 425 540 635

345 345 345 345 345 345 345

3 3 3 3 3 3 3

10 8 8 8 8 7 6

0.364 0.408 0.458 0.515 0.561 0.664 0.794

1.11 1.15 1.2 1.26 1.31 1.41 1.54

1.18 1.22 1.27 1.33 1.38 1.48 1.63

2.88 2.97 3.08 3.21 3.32 3.54 3.86

3031 3303 3555 3859 4132 4785 5771

21 21 22 23 24 25 27

150 170 195 220 245 295 355

170 190 220 255 280 345 425

345 345 345 345 345 345 345

3 3 3 3 3 3 3

10 8 8 8 8 7 6

0.364 0.408 0.458 0.515 0.561 0.664 0.794

1.11 1.15 1.2 1.26 1.31 1.41 1.54

1.18 1.22 1.27 1.33 1.38 1.48 1.63

2.88 2.97 3.08 3.21 3.32 3.54 3.86

3031 3303 3555 3859 4132 4785 5771

21 21 22 23 24 25 27

150 170 195 220 245 295 355

170 190 220 255 280 345 425

420 420 420 420 420 420 420

3 3 3 3 3 3 3

10 8 8 8 8 7 6

0.364 0.408 0.458 0.515 0.561 0.664 0.794

1.26 1.3 1.35 1.41 1.46 1.57 1.7

1.33 1.38 1.43 1.48 1.54 1.65 1.78

3.21 3.31 3.41 3.54 3.65 3.91 4.19

3626 3914 4184 4509 4800 5580 6531

23 24 24 25 26 28 30

150 170 195 220 245 295 355

170 190 220 255 280 345 425

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 317 20150519

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

PowerGuard® 15kV 133% Shielded Power Cable AL Conductor 220 mils EPR Copper Tape PVC Jacket MV-105 Applications For installation in tray, trough, conduit, ducts, aerial and direct buried as allowed by the NEC. The cables can be used in main feeder, distribution, and branch circuits for industrial, commercial and electric utility installations. They may operate continuously in wet or dry locations at conductor temperatures not exceeding 105°C, at not more than 140°C. for emergency overload conditions and 250°C during short circuits. Suitable for systems rated 15 kV 100% insulation level (grounded systems). Suitable for Direct Burial. Sunlight Resistant. Construction Aluminum concentrically stranded compressed conductor; triple single head extruded conductor shield, EPR (ethylene propylene rubber) insulation and easy strippable insulation shield, all dry cured; bare copper tape shielded; surface printed black PVC jacket.

A2-01PC15EPPU2 A1/0-01PC15EPPU2 A2/0-01PC15EPPU2 A4/0-01PC15EPPU2 A250-01PC15EPPU2 A350-01PC15EPPU2 A500-01PC15EPPU2 A750-01PC15EPPU2 A1000-01PC15EPPU2

Notes • Ampacities are based on the NEC. • Cable Tray: Three single cables, installed in uncovered cable tray in accordance with NEC Section 392.13; operating at 105°C conductor, at an ambient temperature of 40°C. • Buried Duct: Three cables per duct operating at 105°C conductor, 20°C ground ambient, earth ρ = 90, 100% load factor. • Conduit in Air: Three cables per isolated conduit in air at 40°C; operating at 105°C conductor (NEC Table 310.73).

Size/AWG

Insulation Thickness (in)

Conductor Diameter (in)

Insulation Diameter (in)

Overall Diameter (in)

Approx. Weight lb/MFT

Insulation Shield (in)

2 1/0 2/0 4/0 250 350 500 750 1000

.220 .220 .220 .220 .220 .220 .220 .220 .220

.266 .336 .379 .479 .522 .622 .742 .917 1.071

0.74 0.81 0.86 0.96 1.01 1.11 1.23 1.41 1.57

0.96 1.03 1.08 1.18 1.23 1.33 1.45 1.63 1.84

484 566 620 761 834 992 1216 1574 2028

0.80 0.87 0.91 1.01 1.06 1.16 1.28 1.47 1.62

Ampacity (Amps) 105°C in Duct 130 165 190 245 270 330 400 490 565

Ampacity (Amps) 105C in Air 170 225 260 350 385 480 600 780 940

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

319 20160302

MEDIUM VOLTAGE CABLES

Item #

Standards • National Electrical Code (NEC) • UL-1072 MV-105 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • AEIC CS8 • UL listed as Type MV-105 for use in accordance with NEC • Sizes 1/0 AWG and larger are listed and marked “Sunlight-Resistant FOR CT USE” in accordance with NEC

MEDIUM VOLAGE CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

PowerGuard® Testing Recommendations June 7, 2016 Regarding field testing cables for commissioning, we recommend the VLF Testing in Accordance to IEEE 400: IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems in accordance to Table 1 IEEE400.2 VLF Test Voltage Levels for Sinusoidal, Cosine-Rectangular. Voltage Peak values are shown in brackets for Cosine-Rectangular and Squarewave. The most important application part of the new IEEE400.2 cable testing guide is the Table 1 below that shows the recommended VLF Hipot voltage testing levels for the various medium voltage cable ratings for both new (Acceptance and Installation Testing) and old (Maintenance Testing) cable installations. This is a Pass/Fail type test, the cable either withstands the specified test voltage or it does not. The IEEE400 defines types of field tests: Installation Test This test is conducted after the installation of the cable but before the installation ofaccessories like the splices and terminations. Its purpose is to detect any transport, manufacturing, storage or installation defects. Acceptance Test This test is performed after the installation of the accessories, but before energization ofthe cable. It checks for installation defects of the complete cable system, as well as defects as a result of shipping, manufacturing or storage. Test Frequency VLF test frequency is 0.1Hz of a testing of 30 minutes.

Installation Test phase to ground

Acceptance Test phase to ground

Maintenance Test phase to ground

kV rms (or peak) 9 (13) 11 (16) 18 (25) 27 (38) 39 (55)

kV rms (or peak) 10 (14) 13 (18) 20 (28) 31 (44) 44 (62)

kV rms (or peak) 7 (10) 10 (14) 16 (22) 23 (33) 33 (47)

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

321 20170306

MEDIUM VOLTAGE CABLES

Cable Rating phase to phase (RMS) kV rms 5 8 15 25 35

MEDIUM VOLAGE CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

ARMORED CABLES Table of Contents UL Type MC Two Conductor Aluminum with Ground PVC Jacket 600V ............................236 UL Type MC Three Conductor Aluminum with Ground PVC Jacket 600V .........................237 UL Type MC Four Conductor Aluminum with Ground PVC Jacket 600V...........................238 UL Type MC Two Conductor Aluminum with Ground PVC Jacket 2kV ..............................235 Type MC Three Conductor w/Ground Aluminum Armor XHHW2 600V.............................911 Type MC Four Conductor w/Ground Aluminum Armor XHHW-2 600V.............................912 PowerGuard® Armored Copper Three Conductor 5kV-35kV ..............................................903 PowerGuard® Armored Aluminum Three Conductor 5kV-35kV .........................................904 Continuously Corrugated Welded Armored Power Cable, FR-XLP Insulation (XHHW-2), 600V/1kV, Type MC-HL 1/C.....................................................................................................905 Continuously Corrugated Welded Armored Power Cable, FR-XLP Insulation (XHHW-2), 600V/1kV, Type MC-HL 2/C.....................................................................................................906 Continuously Corrugated Welded Armored Power Cable, FR-XLP Insulation (XHHW-2), 600V/1kV, Type MC-HL 3/C.....................................................................................................907 Continuously Corrugated Welded Armored Power Cable, FR-XLP Insulation (XHHW-2), 600V/1kV, Type MC-HL 4/C.....................................................................................................908 Continuously Corrugated Welded Armored Power Cable, FR-XLP Insulation (XHHW-2), 600V/1kV, Type MC-HL 5/C.....................................................................................................909 UL Type MC Copper Conductor with Ground PVC Jacket 600V .........................................910

ARMORED CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

900 20180201

ARMORED CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

UL Type MC Two Conductor Aluminum with Ground PVC Jacket 600V Applications MC Cable is approved for use in many applications including direct burial, use in cable tray and outdoor exposure. The PVC jacket is free of harmful heavy metals in compliance with RoHS, Directive 2002/95/EC. • Run from the combiner box to the inverter • Suitable for rooftop solar applications • Outdoors • In wet locations (Type XHHW-2, or RHW-2 conductors) • Direct buried • Encased in concrete • Hazardous locations • Strong, but lightweight alloy armor resists damage • Suitable for wet locations, direct burial, encased in concrete and other uses per the NEC • More flexible than conduit • Factory tested engineered product that protects conductors from damage during installation • Meets or exceeds requirements of the NEC, as well as applicable UL Standards. Construction Stranded aluminum alloy (AA8000) compacted conductor, Class B stranding, per ASTM B 801.

Item #

Conductor Size AWG/ kcmil

Grounding Conductor AWG/ kcmil

Cable Diameter Under Armor (in)

Cable Diameter Over Armor (in)

Cable Diameter Over PVC Jacket (in)

Cable Weight (lb/MFT)

6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 750

8 6 6 4 4 4 4 2 2 2 2 1 1 1/0

0.56 0.65 0.76 0.86 0.93 1.01 1.11 1.21 1.34 1.44 1.53 1.62 1.77 2.18

0.75 0.84 0.95 1.05 1.12 1.21 1.3 1.41 1.6 1.7 1.79 1.88 2.03 2.43

0.85 0.94 1.05 1.15 1.22 1.31 1.4 1.51 1.72 1.82 1.91 2 2.15 2.58

243.5 306.5 383.9 472.9 537.5 626.4 723.1 864.8 1048 1180.5 1310.3 1431.2 1674.6 2417

Data isApproximateAnd subject to normal manufacturing tolerances. For sizes not listedAbove please contact sales.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

236 20140924

ARMORED CABLES

A6-02AIA-WG-600V A4-02AIA-WG-600V A2-02AIA-WG-600V A1-02AIA-WG-600V A1/0-02AIA-WG-600V A2/0-02AIA-WG-600V A3/0-02AIA-WG-600V A4/0-02AIA-WG-600V A250-02AIA-WG-600V A300-02AIA-WG-600V A350-02AIA-WG-600V A400-02AIA-WG-600V A500-02AIA-WG-600V A750-02AIA-WG-600V

Flame retardant thermoset crosslinked polyethylene (XLPE) insulation. Grounding is one bare aluminum alloy (AA-8000) compacted stranded conductor. Phase and grounding conductors are cabled together with binder tape. Aluminum interlocked armor, applied over the binder tape and a longitudinal marker tape, for ID, when unjacketed. Black sunlight resistant and flame retardant polyvinyl chloride (PVC) compound jacket. Standards • Single conductors are rated XHHW-2 600V, and CT Use 1/0AWG and larger. Additional UL Type PV available upon request. • Aluminum armor is rated for Direct Burial, using 6AWG and larger conductors, with overall jacket • UL Type MC-HL available upon request of purchaser where cable is approved for use in certain hazardous locations as permitted in articles 501, 502, 503 and 504 • UL 1569, Metal Clad Cables • UL 44, Rubber-Insulated wires and cables • ICEA S-95-658 Standard for Non-shielded Power Cables Rated 2000 volts or less

ARMORED CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] .

UL Type MC Three Conductor Aluminum with Ground PVC Jacket 600V Applications MC Cable is approved for use in many applications including direct burial, use in cable tray and outdoor exposure. The PVC jacket is free of harmful heavy metals in compliance with RoHS, Directive 2002/95/EC. • Run from the combiner box to the inverter • Suitable for rooftop solar applications • Outdoors • In wet locations (Type XHHW-2, or RHW-2 conductors) • Direct buried • Encased in concrete • Hazardous locations • Strong, but lightweight alloy armor resists damage • Suitable for wet locations, direct burial, encased in concrete and other uses per the NEC • More flexible than conduit • Factory tested engineered product that protects conductors from damage during installation • Meets or exceeds requirements of the NEC, as well as applicable UL Standards Construction Stranded aluminum alloy (AA8000) compacted conductor, Class B stranding, per ASTM B 801.

Item #

Conductor Size AWG/ kcmil

Grounding Conductor AWG/ kcmil

Cable Diameter Under Armor (in)

Cable Diameter Over Armor (in)

Cable Diameter Over PVC Jacket (in)

Cable Weight (lb/MFT)

4 2 1 1/0 2/0 3/0 40 250 300 350 400 500 600 700 750 900

6 6 4 4 4 4 2 2 2 2 2 1 1 1/0 1/0 250

0.68 0.77 0.90 0.96 1.05 1.13 1.27 1.40 1.51 1.61 1.70 1.87 2.10 2.24 2.30 2.50

0.09 1.00 1.12 1.18 1.28 1.36 1.55 1.69 1.79 1.89 1.99 2.15 2.38 2.52 2.59 2.78

1.00 1.09 1.22 1.28 1.38 1.46 1.67 1.81 1.91 2.01 2.11 2.72 2.53 2.67 2.74 2.93

380 482 595 691 813 950 1176 1381 1570 1755 1919 2269 2766 3134 3306 3959

Data is approximate and subject to normal manufacturing tolerances. For sizes not listed above please contact sales.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

237 20140921

ARMORED CABLES

A4-03AIA-WG-600V A2-03AIA-WG-600V A1-03AIA-WG-600V A1/0-03AIA-WG-600V A2/0-03AIA-WG-600V A3/0-03AIA-WG-600V A40-03AIA-WG-600V A250-03AIA-WG-600V A300-03AIA-WG-600V A350-03AIA-WG-600V A400-03AIA-WG-600V A500-03AIA-WG-600V A600-03AIA-WG-600V A700-03AIA-WG-600V A750-03AIA-WG-600V A900-03AIA-WG-600V

Flame retardant thermoset crosslinked polyethylene (XLPE) insulation. Grounding is one bare aluminum alloy (AA-8000) compacted stranded conductor. Phase and grounding conductors are cabled together with binder tape. aluminum interlocked armor, applied over the binder tape and a longitudinal marker tape, for ID, when unjacketed. Black sunlight resistant and flame retardant polyvinyl chloride (PVC) compound jacket. Specifications • Single conductors are rated XHHW-2 600V, and CT Use 1/0AWG and larger. Additional UL Type PV available upon request. • Aluminum armor is rated for Direct Burial, using 6AWG and larger conductors, with overall jacket • UL Type MC-HL available upon request of purchaser where cable is approved for use in certain hazardous locations as permitted in articles 501, 502, 503 and 504 • UL 1569, Metal Clad Cables • UL 44, Rubber-Insulated wires and cables • ICEA S-95-658 Standard for Non-shielded Power Cables Rated 2000 volts or less

ARMORED CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

UL Type MC Four Conductor Aluminum with Ground PVC Jacket 600V Applications MC Cable is approved for use in many applications including direct burial, use in cable tray and outdoor exposure. The PVC jacket is free of harmful heavy metals in compliance with RoHS, Directive 2002/95/EC. • Run from the combiner box to the inverter • Suitable for rooftop solar applications • Outdoors • In wet locations (Type XHHW-2 , or RHW-2 conductors) • Direct buried • Encased in concrete • Hazardous locations • Strong, but lightweight alloy armor resists damage • Suitable for wet locations, direct burial, encased in concrete and other uses per the NEC • More flexible than conduit • Factory tested engineered product that protects conductors from damage during installation • Meets or exceeds requirements of the NEC, as well as applicable UL Standards Construction Stranded aluminum alloy (AA8000) compacted conductor, Class B stranding, perASTM B 801.

Item #

Conductor Size AWG/ kcmil

Grounding Conductor AWG/ kcmil

Cable Diameter Under Armor (in)

Cable Diameter Over Armor (in)

Cable Diameter Over PVC Jacket (in)

Cable Weight (lb/MFT)

6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 700 750 700 750 750 900 900

6 6 6 4 4 4 4 2 1 1 1/0 1/0 2/0 250 2/0 400 2/0 3/0 750 250 900

0.70 0.77 0.89 1.03 1.11 1.19 1.32 1.46 1.60 1.70 1.83 1.91 2.11 2.25 2.35 2.61 2.58 2.60 3.04 2.84 3.32

0.92 1.04 1.10 1.25 1.34 1.41 1.58 1.73 1.89 1.99 2.11 2.20 2.39 2.54 2.67 2.89 2.86 2.86 3.30 3.12 3.60

1.02 1.09 1.20 1.35 1.43 1.51 1.70 1.85 2.01 2.11 2.23 2.32 2.54 2.69 2.79 3.01 3.01 3.01 3.50 3.29 3.77

377 474 617 757 871 1071 1235 1480 1730 1970 2231 2469 3028 3166 3591 3886 4043 4300 4998 5087 5844

ARMORED CABLES

A6-04AIA-WG-600V A4-04AIA-WG-600V A2-04AIA-WG-600V A1-04AIA-WG-600V A1/0-04AIA-WG-600V A2/0-04AIA-WG-600V A3/0-04AIA-WG-600V A40-04AIA-WG-600V A250-04AIAWG-600V A300-04AIAWG-600V A350-04AIAWG-600V A400-04AIAWG-600V A500-04AIAWG-600V A600-04AIAWG-600V A700-04AIAWG-600V A750-04AIAWG-600V A700-04AIAWG-600V A750-04AIAWG-600V A750-04AIAWG-600V A900-04AIAWG-600V A900-04AIAWG-600V

Flame retardant thermoset crosslinked polyethylene (XLPE) insulation. Grounding is one bare aluminum alloy (AA-8000) compacted stranded conductor. Phase and grounding conductors are cabled together with binder tape. Aluminum interlocked armor, applied over the binder tape and a longitudinal marker tape, for ID, when unjacketed. Black sunlight resistant and flame retardant polyvinyl chloride (PVC) compound jacket. Specifications • Single conductors are rated XHHW-2 600V, and CT Use 1/0AWG and larger. Additional UL Type PV available upon request. • Aluminum armor is rated for Direct Burial, using 6AWG and larger conductors, with overall jacket • UL Type MC-HL available upon request of purchaser where cable is approved for use in certain hazardous locations as permitted in articles 501, 502, 503 and 504 • UL 1569, Metal Clad Cables • UL 44, Rubber-Insulated wires and cables • ICEA S-95-658 Standard for Non-shielded Power Cables Rated 2000 volts or less

Data is approximate and subject to normal manufacturing tolerances. For sizes not listed above please contact sales.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

238 20141016

ARMORED CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

UL Type MC Two Conductor Aluminum with Ground PVC Jacket 2kV Applications MC Cable is approved for use in many applications including direct burial, use in cable tray and outdoor exposure. The PVC jacket is free of harmful heavy metals in compliance with RoHS, Directive 2002/95/EC. • Run from the combiner box to the inverter • Suitable for rooftop solar applications • Outdoors • In wet locations (Type XHHW-2 , or RHW-2 conductors) • Direct buried • Encased in concrete • Hazardous locations • Strong, but lightweight alloy armor resists damage • Suitable for wet locations, direct burial, encased in concrete and other uses per the NEC • More flexible than conduit • Factory tested engineered product that protects conductors from damage during installation • Meets or exceeds requirements of the NEC, as well as applicable UL Standards. Construction Stranded aluminum alloy (AA8000) compacted conductor, Class B stranding, perASTM B 801.

Item #

Specifications • Single conductors are rated XHHW-2 600V, and CT Use 1/0AWG and larger. Additional UL Type PV available upon request. • Aluminum armor is rated for Direct Burial, using 6AWG and larger conductors, with overall jacket • UL Type MC-HL available upon request of purchaser where cable is approved for use in certain hazardous locations as permitted in articles 501, 502, 503 and 504 • UL 1569, Metal Clad Cables • UL 44, Rubber-Insulated wires and cables • ICEA S-95-658 Standard for Non-shielded Power Cables Rated 2000 volts or less

Conductor Size AWG/ kcmil

Grounding Conductor AWG/ kcmil

Cable Diameter Under Armor (in)

Cable Diameter Over Armor (in)

Cable Diameter Over PVC Jacket (in)

Cable Weight (lb/MFT)

6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 750

8 6 6 4 4 4 4 2 2 2 2 1 1 1/0

0.66 0.75 0.86 1.00 1.07 1.15 1.25 1.35 1.50 1.60 1.69 1.78 1.93 2.34

0.85 0.94 1.05 1.19 1.27 1.35 1.44 1.61 1.76 1.86 1.95 2.04 2.19 2.59

0.95 1.04 1.15 1.29 1.37 1.45 1.54 1.73 1.88 1.98 2.07 2.16 2.31 2.74

284.9 351.1 432.5 540.6 626.8 709.0 810.3 1014.4 1165.3 1303.4 1438.4 1564.2 1816.2 2585.7

Data is approximate and subject to normal manufacturing tolerances. For sizes not listed above please contact sales.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

235 20140921

ARMORED CABLES

A6-02AIA-WG-2KV A4-02AIA-WG-2KV A2-02AIA-WG-2KV A1-02AIA-WG-2KV A1/0-02AIA-WG-2KV A2/0-02AIA-WG-2KV A3/0-02AIA-WG-2KV A4/0-02AIA-WG-2KV A250-02AIA-WG-2KV A300-02AIA-WG-2KV A350-02AIA-WG-2KV A400-02AIA-WG-2KV A500-02AIA-WG-2KV A750-02AIA-WG-2KV

Flame retardant thermoset crosslinked polyethylene (XLPE) insulation. Grounding is one barealuminum alloy (AA-8000) compacted stranded conductor. Phase and grounding conductors are cabled together with binder tape. Aluminum interlocked armor, applied over the binder tape and a longitudinal marker tape, for ID, when unjacketed. Black sunlight resistant and flame retardant polyvinyl chloride (PVC) compound jacket.

ARMORED CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Type MC Three Conductor w/Ground Aluminum Armor XHHW2 600V Applications Type MC Cable is primarily used for services, feeders, and branch circuits as specified in the 2011 National Electric Code. Type MC cable with Type XHHW2 conductors may be used in wet or dry locations at temperatures not to exceed 90°C. Used for power and lighting indoors, exposed or concealed, in cable tray where identified for such use in a raceway, or in dry locations and embedded in plaster or against other masonry. Voltage rating for XHHW2 conductors is 600V. Construction Compact stranded AA-8000 series aluminum conductor material per ASTM B800, ASTM B801, ASTM B836, ASTM B901 (Single Input Wire), as applicable. A binder tape is wrapped over the conductors with interlocked aluminum tape applied over the assembly. Rated 90°C wet or dry and is flame and sunlight resistant. XLPE insulated XHHW2 conductors and insulated grounding conductor surrounded with aluminum armor (Metal Clad).

IItem#

Size of Cable

A12-03MC12 A10-03MC10 A8-03MC10 A8-03MC8 A6-03MC8 A6-03MC6 A4-03MC6 A4-03MC4 A3-03MC6 A3-03MC4 A3-03MC3 A2-03MC6 A2-03MC4

12-12-12+12 10-10-10+10 8-8-8+10 8-8-8+8 6-6-6+8 6-6-6+6 4-4-4+6 4-4-4+4 3-3-3+6 3-3-3+4 3-3-3+3 2-2-2+6 2-2-2+4

Color Code Three Phase Conductors (3): Black, red, white Ground Conductor (1): Green Other colors and stripes available by special order. For Special Order • The entire assembly can be covered with a PVC or CPE outer jacket (black or color). Jacketed MC Cable may be used in wet locations, either direct burial, in underground conduit, or overhead. • Halogen free jackets are available upon request • A black jacket (on individual conductors) with color stripes can be requested. • Bare Ground conductor available upon request. • For sizes not listed above please contact sales. Ampacity To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.

Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT) AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor MCM (mils) AWG/MCM (mils) 12 10 8 8 6 6 4 4 3 3 3 2 2

3 3 3 3 3 3 3 3 3 3 3 3 3

91 116 134 134 169 169 213 213 238 238 238 268 268

30 30 45 45 45 45 45 45 45 45 45 45 45

12 10 10 8 8 6 6 4 6 4 3 6 4

91 116 116 134 134 169 169 213 169 213 238 169 213

30 30 30 45 45 45 45 45 45 45 45 45 45

366 425 528 543 618 626 720 732 772 795 795 843 850

640 699 801 817 892 900 994 1006 1045 1069 1069 1116 1124

93 116 149 157 196 206 264 280 302 320 330 350 366

119 147 198 212 258 271 339 358 382 404 415 438 456

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

911 20180201

ARMORED CABLES

Specifications Type MC cable with Type XHHW2 conductors are manufactured and tested in accordance with the latest revisions of: • UL 44 for Thermoset-Insulated Wires and Cables • UL 83 for Thermoplastic-Insulated Wires and Cables • UL 1479 Standard for Fire Tests of ThroughPenetration Firestops. • UL Classified 1, 2, and 3 Hour Through-Penetration Firestop Systems.

• UL 1569 for Metal-Clad Cables. • IEEE 1202 Flame Testing of Cables for Use in Cable Tray, in Industrial and Commercial Occupancies (70,000 BTU/hr). • ICEA T29520 Vertical Cable Tray Flame Tests (210,000 Btu/hr). • ICEA S66524 and requirements of the National Electric Code • ICEA S95658 (NEMA WC 70) construction requirements • Federal Specification JC30B

Type MC Three Conductor w/Ground Aluminum Armor XHHW2 600V

ARMORED CABLES

Item#

A2-03MC2 A1-03MC4 A1-03MC3 A1-03MC2 A1-03MC1 A1/0-03MC4 A1/0-03MC3 A1/0-03MC2 A1/0-03MC1 A1/0-03MC1/0 A2/0-03MC4 A2/0-03MC2 A2/0-03MC1 A2/0-03MC1/0 A2/0-03MC2/0 A3/0-03MC4 A3/0-03MC2 A3/0-03MC1 A3/0-03MC1/0 A3/0-03MC2/0 A3/0-03MC3/0 A4/0-03MC2 A4/0-03MC1 A4/0-03MC1/0 A4/0-03MC2/0 A4/0-03MC3/0 A4/0-03MC4/0 A250-03MC2 A250-03MC1 A250-03MC1/0 A250-03MC2/0 A250-03MC3/0 A250-03MC4/0 A250-03MC250 A300-03MC2 A300-03MC1 A300-03MC1/0 A300-03MC2/0 A300-03MC3/0 A300-03MC4/0 A300-03MC250 A300-03MC300 A350-03MC2 A350-03MC1 A350-03MC1/0

Size of Cable

2-2-2+2 1-1-1+4 1-1-1+3 1-1-1+2 1-1-1+1 1/0-1/0-1/0+4 1/0-1/0-1/0+3 1/0-1/0-1/0+2 1/0-1/0-1/0+1 1/0-1/0-1/0+1/0 2/0-2/0-2/0+4 2/0-2/0-2/0+2 2/0-2/0-2/0+1 2/0-2/0-2/0+1/0 2/0-2/0-2/0+2/0 3/0-3/0-3/0+4 3/0-3/0-3/0+2 3/0-3/0-3/0+1 3/0-3/0-3/0+1/0 3/0-3/0-3/0+2/0 3/0-3/0-3/0+3/0 4/0-4/0-4/0+2 4/0-4/0-4/0+1 4/0-4/0-4/0+1/0 4/0-4/0-4/0+2/0 4/0-4/0-4/0+3/0 4/0-4/0-4/0+4/0 250-250-250+2 250-250-250+1 250-250-250+1/0 250-250-250+2/0 250-250-250+3/0 250-250-250+4/0 250-250-250+250 300-300-300+2 300-300-300+1 300-300-300+1/0 300-300-300+2/0 300-300-300+3/0 300-300-300+4/0 300-300-300+250 300-300-300+300 350-350-350+2 350-350-350+1 350-350-350+1/0

Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT) AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor MCM (mils) AWG/MCM (mils) 2 1 1 1 1 1/2000 1/2000 1/2000 1/2000 1/2000 2/2000 2/2000 2/2000 2/2000 2/2000 3/2000 3/2000 3/2000 3/2000 3/2000 3/2000 4/2000 4/2000 4/2000 4/2000 4/2000 4/2000 250 250 250 250 250 250 250 300 300 300 300 300 300 300 300 350 350 350

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

268 299 299 299 299 336 336 336 336 336 376 376 376 376 376 421 421 421 421 421 421 476 476 476 476 476 476 520 520 520 520 520 520 520 571 571 571 571 571 571 571 571 614 614 614

45 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65

2 4 3 2 1 4 3 2 1 1/2000 4 2 1 1/2000 2/2000 4 2 1 1/2000 2/2000 3/2000 2 1 1/2000 2/2000 3/2000 4/2000 2 1 1/2000 2/2000 3/2000 4/2000 250 2 1 1/2000 2/2000 3/2000 4/2000 250 300 2 1 1/2000

268 213 238 268 299 213 238 268 299 336 213 268 299 336 376 213 268 299 336 376 421 268 299 336 376 421 476 268 299 336 376 421 476 520 268 299 336 376 421 476 520 571 268 299 336

45 45 45 45 55 45 45 45 55 55 45 45 55 55 55 45 45 55 55 55 55 45 55 55 55 55 55 45 55 55 55 55 55 65 45 55 55 55 55 55 65 65 45 55 55

866 961 972 972 988 1028 1047 1063 1079 1079 1118 1142 1157 1177 1177 1197 1220 1248 1264 1283 1283 1346 1346 1378 1394 1417 1417 1461 1496 1496 1528 1547 1575 1575 1579 1579 1614 1614 1650 1669 1697 1697 1638 1673 1673

1140 1234 1246 1246 1262 1301 1321 1337 1352 1352 1392 1415 1431 1451 1451 1470 1494 1522 1537 1557 1557 1620 1620 1652 1667 1691 1691 1734 1820 1820 1851 1871 1898 1898 1902 1902 1938 1938 1973 1993 2020 2020 1961 1997 1997

391 431 443 456 474 503 516 531 549 569 592 618 637 660 685 700 726 747 769 798 830 866 882 907 935 970 1010 993 1065 1086 1116 1152 1197 1234 1201 1217 1244 1269 1308 1351 1393 1438 1348 1371 1391

485 548 562 576 603 629 644 662 689 712 730 760 787 814 842 850 880 909 935 967 1003 1035 1060 1088 1119 1159 1204 1203 1284 1308 1342 1382 1432 1482 1428 1452 1483 1511 1554 1602 1657 1708 1589 1620 1643

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 911 20180201

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Type MC Three Conductor w/Ground Aluminum Armor XHHW2 600V Item#

350-350-350+2/0 350-350-350+3/0 350-350-350+4/0 350-350-350+250 350-350-350+300 350-350-350+350 400-400-400+1 400-400-400+1/0 400-400-400+2/0 400-400-400+3/0 400-400-400+4/0 400-400-400+250 400-400-400+300 400-400-400+350 400-400-400+400 450-450-450+1 450-450-450+1/0 450-450-450+2/0 450-450-450+3/0 450-450-450+4/0 450-450-450+250 450-450-450+300 450-450-450+350 450-450-450+400 450-450-450+450 500-500-500+1 500-500-500+1/0 500-500-500+2/0 500-500-500+3/0 500-500-500+4/0 500-500-500+250 500-500-500+300 500-500-500+350 500-500-500+400 500-500-500+450 500-500-500+500 600-600-600+1 600-600-600+1/0 600-600-600+2/0 600-600-600+3/0 600-600-600+4/0 600-600-600+250 600-600-600+300 600-600-600+350 600-600-600+400

Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT) AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor MCM (mils) AWG/MCM (mils) 350 350 350 350 350 350 400 400 400 400 400 400 400 400 400 450 450 450 450 450 450 450 450 450 450 500 500 500 500 500 500 500 500 500 500 500 600 600 600 600 600 600 600 600 600

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

614 614 614 614 614 614 657 657 657 657 657 657 657 657 657 701 701 701 701 701 701 701 701 701 701 736 736 736 736 736 736 736 736 736 736 736 815 815 815 815 815 815 815 815 815

65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 80 80 80 80 80 80 80 80 80

2/2000 3/2000 4/2000 250 300 350 1 1/2000 2/2000 3/2000 4/2000 250 300 350 400 1 1/2000 2/2000 3/2000 4/2000 250 300 350 400 450 1 1/2000 2/2000 3/2000 4/2000 250 300 350 400 450 500 1 1/2000 2/2000 3/2000 4/2000 250 300 350 400

376 421 476 520 571 614 299 336 376 421 476 520 571 614 657 299 336 376 421 476 520 571 614 657 701 299 336 376 421 476 520 571 614 657 701 736 299 336 376 421 476 520 571 614 657

55 55 55 65 65 65 55 55 55 55 55 65 65 65 65 55 55 55 55 55 65 65 65 65 65 55 55 55 55 55 65 65 65 65 65 65 55 55 55 55 55 65 65 65 65

1713 1748 1748 1772 1799 1799 1772 1772 1811 1811 1850 1874 1874 1906 1906 1827 1870 1870 1913 1953 1953 1976 1976 2012 2012 1906 1949 1949 1992 1992 2035 2063 2063 2094 2094 2094 2106 2106 2146 2193 2244 2244 2291 2291 2323

2036 2072 2072 2095 2123 2123 2095 2095 2135 2135 2174 2198 2198 2229 2229 2150 2194 2194 2237 2276 2276 2300 2300 2335 2335 2229 2272 2272 2316 2316 2359 2387 2387 2418 2418 2418 2430 2430 2469 2517 2568 2568 2615 2615 2646

1424 1462 1502 1543 1593 1639 1531 1551 1584 1616 1663 1704 1749 1800 1848 1677 1706 1731 1771 1818 1855 1904 1950 2004 2049 1828 1857 1882 1922 1962 2006 2057 2102 2155 2201 2246 2144 2164 2197 2238 2287 2323 2378 2423 2476

1680 1722 1767 1821 1877 1927 1794 1817 1854 1890 1942 1996 2047 2103 2154 1954 1986 2014 2059 2111 2161 2216 2266 2324 2374 2116 2148 2177 2221 2266 2324 2380 2430 2487 2537 2586 2524 2547 2583 2629 2683 2733 2793 2842 2900

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

911 20180201

ARMORED CABLES

A350-03MC2/0 A350-03MC3/0 A350-03MC4/0 A350-03MC250 A350-03MC300 A350-03MC350 A400-03MC1 A400-03MC1/0 A400-03MC2/0 A400-03MC3/0 A400-03MC4/0 A400-03MC250 A400-03MC300 A400-03MC350 A400-03MC400 A450-03MC1 A450-03MC1/0 A450-03MC2/0 A450-03MC3/0 A450-03MC4/0 A450-03MC250 A450-03MC300 A450-03MC350 A450-03MC400 A450-03MC450 A500-03MC1 A500-03MC1/0 A500-03MC2/0 A500-03MC3/0 A500-03MC4/0 A500-03MC250 A500-03MC300 A500-03MC350 A500-03MC400 A500-03MC450 A500-03MC500 A600-03MC1 A600-03MC1/0 A600-03MC2/0 A600-03MC3/0 A600-03MC4/0 A600-03MC250 A600-03MC300 A600-03MC350 A600-03MC400

Size of Cable

Type MC Three Conductor w/Ground Aluminum Armor XHHW2 600V

ARMORED CABLES

Item#

A600-03MC450 A600-03MC500 A600-03MC600 A650-03MC1 A650-03MC1/0 A650-03MC2/0 A650-03MC3/0 A650-03MC4/0 A650-03MC250 A650-03MC300 A650-03MC350 A650-03MC400 A650-03MC450 A650-03MC500 A650-03MC600 A650-03MC650 A700-03MC1 A700-03MC1/0 A700-03MC2/0 A700-03MC3/0 A700-03MC4/0 A700-03MC250 A700-03MC300 A700-03MC350 A700-03MC400 A700-03MC450 A700-03MC500 A700-03MC600 A700-03MC700 A750-03MC1/0 A750-03MC2/0 A750-03MC3/0 A750-03MC4/0 A750-03MC250 A750-03MC300 A750-03MC350 A750-03MC400 A750-03MC450 A750-03MC500 A750-03MC600 A750-03MC700 A750-03MC750 A800-03MC1/0 A800-03MC2/0 A800-03MC3/0

Size of Cable

600-600-600+450 600-600-600+500 600-600-600+600 650-650-650+1 650-650-650+1/0 650-650-650+2/0 650-650-650+3/0 650-650-650+4/0 650-650-650+250 650-650-650+300 650-650-650+350 650-650-650+400 650-650-650+450 650-650-650+500 650-650-650+600 650-650-650+650 700-700-700+1 700-700-700+1/0 700-700-700+2/0 700-700-700+3/0 700-700-700+4/0 700-700-700+250 700-700-700+300 700-700-700+350 700-700-700+400 700-700-700+450 700-700-700+500 700-700-700+600 700-700-700+700 750-750-750+1/0 750-750-750+2/0 750-750-750+3/0 750-750-750+4/0 750-750-750+250 750-750-750+300 750-750-750+350 750-750-750+400 750-750-750+450 750-750-750+500 750-750-750+600 750-750-750+700 750-750-750+750 800-800-800+1/0 800-800-800+2/0 800-800-800+3/0

Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT) AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor MCM (mils) AWG/MCM (mils) 600 600 600 650 650 650 650 650 650 650 650 650 650 650 650 650 700 700 700 700 700 700 700 700 700 700 700 700 700 750 750 750 750 750 750 750 750 750 750 750 750 750 800 800 800

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

815 815 815 843 843 843 843 843 843 843 843 843 843 843 843 843 878 878 878 878 878 878 878 878 878 878 878 878 878 909 909 909 909 909 909 909 909 909 909 909 909 909 937 937 937

80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80

450 500 600 1 1/2000 2/2000 3/2000 4/2000 250 300 350 400 450 500 600 650 1 1/2000 2/2000 3/2000 4/2000 250 300 350 400 450 500 600 700 1/2000 2/2000 3/2000 4/2000 250 300 350 400 450 500 600 700 750 1/2000 2/2000 3/2000

701 736 815 299 336 376 421 476 520 571 614 657 701 736 815 843 299 336 376 421 476 520 571 614 657 701 736 815 878 336 376 421 476 520 571 614 657 701 736 815 878 909 336 376 421

65 65 80 55 55 55 55 55 65 65 65 65 65 65 80 80 55 55 55 55 55 65 65 65 65 65 65 80 80 55 55 55 55 65 65 65 65 65 65 80 80 80 55 55 55

2323 2323 2358 2165 2165 2209 2256 2256 2307 2307 2358 2358 2386 2386 2429 2429 2244 2244 2244 2335 2335 2390 2390 2441 2441 2472 2472 2512 2512 2307 2307 2350 2406 2457 2457 2457 2512 2512 2543 2587 2587 2587 2370 2370 2413

2646 2646 2682 2489 2489 2532 2580 2580 2631 2631 2682 2682 2709 2709 2753 2753 2568 2568 2568 2658 2658 2713 2713 2765 2765 2796 2796 2835 2835 2631 2631 2674 2729 2780 2780 2780 2835 2835 2867 2910 2910 2910 2694 2694 2737

2521 2567 2666 2291 2311 2345 2386 2425 2471 2517 2572 2619 2669 2715 2816 2861 2448 2468 2493 2542 2582 2628 2674 2729 2776 2827 2873 2973 3065 2616 2641 2681 2731 2777 2822 2868 2925 2971 3022 3123 3215 3261 2764 2789 2829

2950 2999 3129 2682 2705 2742 2787 2832 2892 2942 3002 3054 3109 3158 3289 3338 2852 2875 2904 2957 3002 3063 3113 3173 3225 3280 3329 3460 3560 3036 3064 3108 3164 3224 3274 3324 3386 3436 3491 3622 3723 3772 3194 3223 3267

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 911 20180201

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Type MC Three Conductor w/Ground Aluminum Armor XHHW2 600V Item#

Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT) AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor MCM (mils) AWG/MCM (mils)

800-800-800+4/0 800-800-800+250 800-800-800+300 800-800-800+350 800-800-800+400 800-800-800+450 800-800-800+500 800-800-800+600 800-800-800+700 800-800-800+750 800-800-800+800 900-900-900+2/0 900-900-900+3/0 900-900-900+4/0 900-900-900+250 900-900-900+300 900-900-900+350 900-900-900+400 900-900-900+450 900-900-900+500 900-900-900+600 900-900-900+700 900-900-900+750 900-900-900+800 900-900-900+900 900-900-900+1000 1000-1000-1000+2/0 1000-1000-1000+3/0 1000-1000-1000+4/0 1000-1000-1000+250 1000-1000-1000+300 1000-1000-1000+350 1000-1000-1000+400 1000-1000-1000+450 1000-1000-1000+500 1000-1000-1000+600 1000-1000-1000+650 1000-1000-1000+700 1000-1000-1000+750 1000-1000-1000+800 1000-1000-1000+900 1000-1000-1000+1000

800 800 800 800 800 800 800 800 800 800 800 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

937 937 937 937 937 937 937 937 937 937 937 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1059 1059 1059 1059 1059 1059 1059 1059 1059 1059 1059 1059 1059 1059 1059 1059

80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80

4/2000 250 300 350 400 450 500 600 700 750 800 2/2000 3/2000 4/2000 250 300 350 400 450 500 600 700 750 800 900 1000 2/2000 3/2000 4/2000 250 300 350 400 450 500 600 650 700 750 800 900 1000

476 520 571 614 657 701 736 815 878 909 937 376 421 476 520 571 614 657 701 736 815 878 909 937 1000 1059 376 421 476 520 571 614 657 701 736 815 843 878 909 937 1000 1059

55 65 65 65 65 65 65 80 80 80 80 55 55 55 65 65 65 65 65 65 80 80 80 80 80 80 55 55 55 65 65 65 65 65 65 80 80 80 80 80 80 80

2469 2469 2524 2524 2579 2579 2579 2610 2654 2654 2654 2504 2504 2610 2610 2669 2669 2669 2724 2724 2760 2760 2807 2807 2807 2807 2634 2634 2681 2744 2744 2803 2803 2803 2866 2902 2902 2902 2902 2902 2949 2949

2792 2792 2847 2847 2902 2902 2902 2934 2977 2977 2977 2828 2828 2934 2934 2993 2993 2993 3048 3048 3083 3083 3131 3131 3131 3131 2957 2957 3005 3068 3068 3127 3127 3127 3190 3225 3225 3225 3225 3225 3272 3272

2879 2916 2971 3017 3074 3120 3165 3264 3364 3410 3455 3092 3124 3184 3220 3276 3322 3369 3425 3470 3569 3662 3716 3762 3854 3947 3394 3426 3475 3523 3568 3625 3672 3717 3775 3874 3919 3966 4012 4057 4159 4251

3323 3372 3434 3483 3546 3595 3644 3773 3882 3931 3980 3550 3586 3652 3701 3763 3813 3865 3925 3974 4104 4204 4263 4312 4412 4512 3875 3911 3965 4027 4078 4139 4191 4240 4302 4431 4480 4532 4581 4630 4739 4839

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

911 20180201

ARMORED CABLES

A800-03MC4/0 A800-03MC250 A800-03MC300 A800-03MC350 A800-03MC400 A800-03MC450 A800-03MC500 A800-03MC600 A800-03MC700 A800-03MC750 A800-03MC800 A900-03MC2/0 A900-03MC3/0 A900-03MC4/0 A900-03MC250 A900-03MC300 A900-03MC350 A900-03MC400 A900-03MC450 A900-03MC500 A900-03MC600 A900-03MC700 A900-03MC750 A900-03MC800 A900-03MC900 A900-03MC1000 A1000-03MC2/0 A1000-03MC3/0 A1000-03MC4/0 A1000-03MC250 A1000-03MC300 A1000-03MC350 A1000-03MC400 A1000-03MC450 A1000-03MC500 A1000-03MC600 A1000-03MC650 A1000-03MC700 A1000-03MC750 A1000-03MC800 A1000-03MC900 A1000-03MC1000

Size of Cable

ARMORED CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Type MC Four Conductor w/Ground Aluminum Armor XHHW-2 600V Applications Type MC Cable is primarily used for services, feeders, and branch circuits as specified in the 2011 National Electric Code. Type MC cable with Type XHHW2 conductors may be used in wet or dry locations at temperatures not to exceed 90°C. Used for power and lighting indoors, exposed or concealed, in cable tray where identified for such use; in a raceway, or in dry locations and embedded in plaster or against other masonry. Voltage rating for XHHW2 conductors is 600V. Construction Compact stranded AA8000 series aluminum conductor material per ASTM B800, ASTM B801, ASTM B836, ASTM B901 (Single Input Wire), as applicable. A binder tape is wrapped over the conductors with interlocked aluminum tape applied over the assembly. Rated 90°C wet or dry and is flame and sunlight resistant. XLPE insulated XHHW2 conductors and insulated grounding conductor surrounded with aluminum armor (Metal Clad).

Item#

A10-04MC10 A8-04MC10 A8-04MC8 A6-04MC8 A6-04MC6 A4-04MC6 A4-04MC4 A3-04MC6 A3-04MC4 A3-04MC3 A2-04MC6 A2-04MC4

Size of Cable

10-10-10-10+10 8-8-8-8+10 8-8-8-8+8 6-6-6-6+8 6-6-6-6+6 4-4-4-4+6 4-4-4-4+4 3-3-3-3+6 3-3-3-3+4 3-3-3-3+3 2-2-2-2+6 2-2-2-2+4

Color Code Four Phase Conductors (4): Black, red, blue, white Grounding Conductor (1): Green Other colors and stripes available by special order. For Special Order • The entire assembly can be covered with a PVC or CPE outer jacket (black or color). Jacketed MC Cable may be used in wet locations, either direct burial, in underground conduit, or overhead. • Halogen free jackets are available upon request • A black jacket (on individual conductors) with color stripes can be requested. • Bare Ground conductor available upon request. • For sizes not listed above please contact sales. Ampacity To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.

Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT) AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor MCM (mils) AWG/MCM (mils) 10 8 8 6 6 4 4 3 3 3 2 2

4 4 4 4 4 4 4 4 4 4 4 4

116 134 134 169 169 213 213 238 238 238 268 268

30 45 45 45 45 45 45 45 45 45 45 45

10 10 8 8 6 6 4 6 4 3 6 4

116 116 134 134 169 169 213 169 213 238 169 213

30 30 45 45 45 45 45 45 45 45 45 45

476 583 606 685 701 803 819 854 886 886 929 949

750 856 880 959 974 1077 1093 1128 1159 1159 1203 1222

134 173 182 230 242 315 332 363 382 392 425 442

172 234 250 308 322 409 429 464 487 498 535 555

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

912 20180201

ARMORED CABLES

Specifications Type MC cable with Type XHHW2 conductors are manufactured and tested in accordance with the latest revisions of: • UL 44 for Thermoset Insulated Wires and Cables • UL 83 for Thermoplastic Insulated Wires and Cables • UL 1479 Standard for Fire Tests of Through Penetration Firestops. • UL Classified 1, 2, and 3 Hour Through Penetration Firestop Systems.

• UL 1569 for Metal Clad Cables. • IEEE 1202 Flame Testing of Cables for Use in Cable Tray, in Industrial and Commercial Occupancies (70,000 BTU/hr). • ICEA T29520 Vertical Cable Tray Flame Tests (210,000 Btu/hr). • ICEA S66524 and requirements of the National Electric Code • ICEA S95658 (NEMA WC 70) construction requirements • Federal Specification JC30B

Type MC Four Conductor w/Ground Aluminum Armor XHHW-2 600V

ARMORED CABLES

Item#

A2-04MC2 A1-04MC4 A1-04MC3 A1-04MC2 A1-04MC1 A1/0-04MC4 A1/0-04MC3 A1/0-04MC2 A1/0-04MC1 A1/0-04MC1/0 A2/0-04MC4 A2/0-04MC2 A2/0-04MC1 A2/0-04MC1/0 A2/0-04MC2/0 A3/0-04MC4 A3/0-04MC2 A3/0-04MC1 A3/0-04MC1/0 A3/0-04MC2/0 A3/0-04MC3/0 A4/0-04MC2 A4/0-04MC1 A4/0-04MC1/0 A4/0-04MC2/0 A4/0-04MC3/0 A4/0-04MC4/0 A250-04MC2 A250-04MC1 A250-04MC1/0 A250-04MC2/0 A250-04MC3/0 A250-04MC4/0 A250-04MC250 A300-04MC2 A300-04MC1 A300-04MC1/0 A300-04MC2/0 A300-04MC3/0 A300-04MC4/0 A300-04MC250 A300-04MC300 A350-04MC2 A350-04MC1 A350-04MC1/0

Size of Cable

Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT) AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor MCM (mils) AWG/MCM (mils)

2-2-2-2+2 1-1-1-1+4 1-1-1-1+3 1-1-1-1+2 1-1-1-1+1 1/0-1/0-1/0-1/0+4 1/0-1/0-1/0-1/0+3 1/0-1/0-1/0-1/0+2 1/0-1/0-1/0-1/0+1 1/0-1/0-1/0-1/0+1/0 2/0-2/0-2/0-2/0+4 2/0-2/0-2/0-2/0+2 2/0-2/0-2/0-2/0+1 2/0-2/0-2/0-2/0+1/0 2/0-2/0-2/0-2/0+2/0 3/0-3/0-3/0-3/0+4 3/0-3/0-3/0-3/0+2 3/0-3/0-3/0-3/0+1 3/0-3/0-3/0-3/0+1/0 3/0-3/0-3/0-3/0+2/0 3/0-3/0-3/0-3/0+3/0 4/0-4/0-4/0-4/0+2 4/0-4/0-4/0-4/0+1 4/0-4/0-4/0-4/0+1/0 4/0-4/0-4/0-4/0+2/0 4/0-4/0-4/0-4/0+3/0 4/0-4/0-4/0-4/0+4/0 250-250-250-250+2 250-250-250-250+1 250-250-250-250+1/0 250-250-250-250+2/0 250-250-250-250+3/0 250-250-250-250+4/0 250-250-250-250+250 300-300-300-300+2 300-300-300-300+1 300-300-300-300+1/0 300-300-300-300+2/0 300-300-300-300+3/0 300-300-300-300+4/0 300-300-300-300+250 300-300-300-300+300 350-350-350-350+2 350-350-350-350+1 350-350-350-350+1/0

2 1 1 1 1 1/0 1/0 1/0 1/0 1/0 2/0 2/0 2/0 2/0 2/0 3/0 3/0 3/0 3/0 3/0 3/0 4/0 4/0 4/0 4/0 4/0 4/0 250 250 250 250 250 250 250 300 300 300 300 300 300 300 300 350 350 350

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

268 299 299 299 299 336 336 336 336 336 376 376 376 376 376 421 421 421 421 421 421 476 476 476 476 476 476 520 520 520 520 520 520 520 571 571 571 571 571 571 571 571 614 614 614

45 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 55 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65

2 4 3 2 1 4 3 2 1 1/0 4 2 1 1/0 2/0 4 2 1 1/0 2/0 3/0 2 1 1/0 2/0 3/0 4/0 2 1 1/0 2/0 3/0 4/0 250 2 1 1/0 2/0 3/0 4/0 250 300 2 1 1/0

268 213 238 268 299 213 238 268 299 336 213 268 299 336 376 213 268 299 336 376 421 268 299 336 376 421 476 268 299 336 376 421 476 520 268 299 336 376 421 476 520 571 268 299 336

45 45 45 45 55 45 45 45 55 55 45 45 55 55 55 45 45 55 55 55 55 45 55 55 55 55 55 45 55 55 55 55 55 65 45 55 55 55 55 55 65 65 45 55 55

965 1063 1083 1083 1106 1138 1161 1181 1205 1205 1240 1264 1287 1311 1311 1327 1354 1382 1406 1433 1433 1492 1492 1524 1551 1583 1583 1626 1657 1657 1689 1724 1756 1756 1752 1752 1787 1787 1823 1858 1894 1894 1846 1862 1862

1238 1337 1356 1356 1380 1411 1435 1455 1478 1478 1514 1537 1561 1585 1585 1600 1628 1656 1679 1707 1707 1816 1816 1847 1875 1906 1906 1950 1981 1981 2013 2048 2080 2080 2076 2076 2111 2111 2146 2182 2217 2217 2170 2186 2186

467 524 537 550 569 617 631 647 666 686 733 760 779 803 828 875 902 922 946 975 1007 1134 1150 1176 1206 1244 1284 1304 1326 1346 1377 1416 1462 1498 1509 1525 1552 1577 1616 1663 1706 1751 1709 1728 1748

584 672 687 701 730 778 794 812 840 863 909 939 968 995 1023 1066 1097 1126 1154 1187 1223 1350 1374 1404 1438 1479 1524 1575 1605 1629 1664 1706 1757 1807 1802 1826 1856 1885 1928 1979 2036 2086 2019 2047 2070

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 912 20180201

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Type MC Four Conductor w/Ground Aluminum Armor XHHW-2 600V Item#

Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT) AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor MCM (mils) AWG/MCM (mils)

350-350-350-350+2/0 350-350-350-350+3/0 350-350-350-350+4/0 350-350-350-350+250 350-350-350-350+300 350-350-350-350+350 400-400-400-400+1 400-400-400-400+1/0 400-400-400-400+2/0 400-400-400-400+3/0 400-400-400-400+4/0 400-400-400-400+250 400-400-400-400+300 400-400-400-400+350 400-400-400-400+400 450-450-450-450+1 450-450-450-450+1/0 450-450-450-450+2/0 450-450-450-450+3/0 450-450-450-450+4/0 450-450-450-450+250 450-450-450-450+300 450-450-450-450+400 450-450-450-450+450 500-500-500-500+1 500-500-500-500+1/0 500-500-500-500+2/0 500-500-500-500+3/0 500-500-500-500+4/0 500-500-500-500+250 500-500-500-500+300 500-500-500-500+350 500-500-500-500+400 500-500-500-500+450 500-500-500-500+500 600-600-600-600+1 600-600-600-600+1/0 600-600-600-600+2/0 600-600-600-600+3/0 600-600-600-600+4/0 600-600-600-600+250 600-600-600-600+300 600-600-600-600+350 600-600-600-600+400 600-600-600-600+450

350 350 350 350 350 350 400 400 400 400 400 400 400 400 400 450 450 450 450 450 450 450 450 450 500 500 500 500 500 500 500 500 500 500 500 600 600 600 600 600 600 600 600 600 600

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

614 614 614 614 614 614 657 657 657 657 657 657 657 657 657 701 701 701 701 701 701 701 701 701 736 736 736 736 736 736 736 736 736 736 736 815 815 815 815 815 815 815 815 815 815

65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 80 80 80 80 80 80 80 80 80 80

2/0 3/0 4/0 250 300 350 1 1/0 2/0 3/0 4/0 250 300 350 400 1 1/0 2/0 3/0 4/0 250 300 400 450 1 1/0 2/0 3/0 4/0 250 300 350 400 450 500 1 1/0 2/0 3/0 4/0 250 300 350 400 450

376 421 476 520 571 614 299 336 376 421 476 520 571 614 657 299 336 376 421 476 520 571 657 701 299 336 376 421 476 520 571 614 657 701 736 299 336 376 421 476 520 571 614 657 701

55 55 55 65 65 65 55 55 55 55 55 65 65 65 65 55 55 55 55 55 65 65 65 65 55 55 55 55 55 65 65 65 65 65 65 55 55 55 55 55 65 65 65 65 65

1898 1933 1933 1972 2008 2008 1969 1969 2008 2008 2047 2087 2087 2102 2126 2063 2079 2079 2118 2161 2161 2201 2244 2244 2150 2165 2165 2209 2209 2252 2295 2295 2339 2339 2339 2358 2417 2417 2437 2488 2488 2535 2535 2583 2583

2221 2257 2257 2296 2331 2331 2292 2292 2331 2331 2371 2410 2410 2426 2450 2387 2402 2402 2442 2485 2485 2524 2568 2568 2473 2489 2489 2532 2532 2576 2619 2619 2662 2662 2662 2682 2741 2741 2761 2812 2812 2859 2859 2906 2906

1780 1818 1858 1902 1954 1999 1936 1957 1989 2021 2069 2112 2158 2206 2258 2136 2159 2184 2223 2271 2308 2360 2461 2507 2333 2357 2382 2422 2462 2506 2560 2605 2661 2706 2751 2743 2775 2800 2835 2885 2921 2975 3021 3077 3122

2105 2148 2193 2250 2308 2357 2274 2297 2333 2369 2422 2479 2529 2582 2639 2491 2518 2546 2590 2643 2693 2751 2861 2910 2704 2731 2759 2803 2848 2906 2965 3015 3075 3125 3174 3236 3271 3299 3339 3394 3443 3503 3553 3614 3663

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

912 20180201

ARMORED CABLES

A350-04MC2/0 A350-04MC3/0 A350-04MC4/0 A350-04MC250 A350-04MC300 A350-04MC350 A400-04MC1 A400-04MC1/0 A400-04MC2/0 A400-04MC3/0 A400-04MC4/0 A400-04MC250 A400-04MC300 A400-04MC350 A400-04MC400 A450-04MC1 A450-04MC1/0 A450-04MC2/0 A450-04MC3/0 A450-04MC4/0 A450-04MC250 A450-04MC300 A450-04MC400 A450-04MC450 A500-04MC1 A500-04MC1/0 A500-04MC2/0 A500-04MC3/0 A500-04MC4/0 A500-04MC250 A500-04MC300 A500-04MC350 A500-04MC400 A500-04MC450 A500-04MC500 A600-04MC1 A600-04MC1/0 A600-04MC2/0 A600-04MC3/0 A600-04MC4/0 A600-04MC250 A600-04MC300 A600-04MC350 A600-04MC400 A600-04MC450

Size of Cable

Type MC Four Conductor w/Ground Aluminum Armor XHHW-2 600V

ARMORED CABLES

Item#

A600-04MC500 A600-04MC600 A650-04MC1 A650-04MC1/0 A650-04MC2/0 A650-04MC3/0 A650-04MC4/0 A650-04MC250 A650-04MC300 A650-04MC350 A650-04MC400 A650-04MC450 A650-04MC500 A650-04MC600 A650-04MC650 A700-04MC1 A700-04MC1/0 A700-04MC2/0 A700-04MC3/0 A700-04MC4/0 A700-04MC250 A700-04MC300 A700-04MC350 A700-04MC400 A700-04MC450 A700-04MC500 A700-04MC600 A700-04MC700 A750-04MC1/0 A750-04MC2/0 A750-04MC3/0 A750-04MC4/0 A750-04MC250 A750-04MC300 A750-04MC350 A750-04MC400 A750-04MC450 A750-04MC500 A750-04MC600 A750-04MC700 A750-04MC750 A800-04MC1/0 A800-04MC2/0 A800-04MC3/0 A800-04MC4/0

Size of Cable

Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT) AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor MCM (mils) AWG/MCM (mils)

600-600-600-600+500 600-600-600-600+600 650-650-650-650+1 650-650-650-650+1/0 650-650-650-650+2/0 650-650-650-650+3/0 650-650-650-650+4/0 650-650-650-650+250 650-650-650-650+300 650-650-650-650+350 650-650-650-650+400 650-650-650-650+450 650-650-650-650+500 650-650-650-650+600 650-650-650-650+650 700-700-700-700+1 700-700-700-700+1/0 700-700-700-700+2/0 700-700-700-700+3/0 700-700-700-700+4/0 700-700-700-700+250 700-700-700-700+300 700-700-700-700+350 700-700-700-700+400 700-700-700-700+450 700-700-700-700+500 700-700-700-700+600 700-700-700-700+700 750-750-750-750+1/0 750-750-750-750+2/0 750-750-750-750+3/0 750-750-750-750+4/0 750-750-750-750+250 750-750-750-750+300 750-750-750-750+350 750-750-750-750+400 750-750-750-750+450 750-750-750-750+500 750-750-750-750+600 750-750-750-750+700 750-750-750-750+750 800-800-800-800+1/0 800-800-800-800+2/0 800-800-800-800+3/0 800-800-800-800+4/0

600 600 650 650 650 650 650 650 650 650 650 650 650 650 650 700 700 700 700 700 700 700 700 700 700 700 700 700 750 750 750 750 750 750 750 750 750 750 750 750 750 800 800 800 800

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

815 815 843 843 843 843 843 843 843 843 843 843 843 843 843 878 878 878 878 878 878 878 878 878 878 878 878 878 909 909 909 909 909 909 909 909 909 909 909 909 909 937 937 937 937

80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80

500 600 1 1/0 2/0 3/0 4/0 250 300 350 400 450 500 600 650 1 1/0 2/0 3/0 4/0 250 300 350 400 450 500 600 700 1/0 2/0 3/0 4/0 250 300 350 400 450 500 600 700 750 1/0 2/0 3/0 4/0

736 815 299 336 376 421 476 520 571 614 657 701 736 815 843 299 336 376 421 476 520 571 614 657 701 736 815 878 336 376 421 476 520 571 614 657 701 736 815 878 909 336 376 421 476

65 80 55 55 55 55 55 65 65 65 65 65 65 80 80 55 55 55 55 55 65 65 65 65 65 65 80 80 55 55 55 55 65 65 65 65 65 65 80 80 80 55 55 55 55

2583 2634 2429 2488 2488 2508 2508 2559 2559 2606 2606 2657 2657 2709 2709 2512 2575 2575 2594 2594 2646 2646 2701 2701 2752 2752 2803 2803 2587 2650 2650 2673 2724 2724 2724 2780 2780 2831 2886 2886 2886 2654 2720 2720 2744

2906 2957 2753 2812 2812 2831 2831 2883 2883 2930 2930 2981 2981 3032 3032 2835 2898 2898 2918 2918 2969 2969 3024 3024 3076 3076 3127 3127 2910 2973 2973 2997 3048 3048 3048 3103 3103 3154 3209 3209 3209 2977 3044 3044 3068

3168 3270 2938 2969 2994 3030 3070 3116 3161 3216 3263 3318 3363 3465 3511 3142 3174 3199 3235 3275 3321 3366 3422 3469 3524 3570 3672 3765 3358 3395 3427 3471 3517 3563 3608 3666 3711 3766 3869 3962 4007 3552 3590 3622 3666

3712 3845 3445 3480 3508 3548 3592 3652 3703 3762 3813 3873 3922 4055 4104 3667 3703 3732 3771 3816 3876 3926 3987 4038 4098 4147 4280 4380 3903 3943 3979 4029 4088 4139 4189 4251 4301 4360 4493 4593 4643 4111 4152 4188 4238

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 912 20180201

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Type MC Four Conductor w/Ground Aluminum Armor XHHW-2 600V Item#

Phase Number Diameter Thickness Size Diameter Thickness Cabling Overall AL Cable Conductor of of of of of Ground of Ground Diameter Diameter Weight Weight Size Phase Conductor Conductor Ground (mils) Insulation (mils) of Cable (lb/MFT) (lb/MFT) AWG/ Conductors (mils) Insulation Conductor (mils) Over Armor MCM (mils) AWG/MCM (mils)

800-800-800-800+250 800-800-800-800+300 800-800-800-800+350 800-800-800-800+400 800-800-800-800+450 800-800-800-800+500 800-800-800-800+600 800-800-800-800+700 800-800-800-800+750 800-800-800-800+800 900-900-900-900+2/0 900-900-900-900+3/0 900-900-900-900+4/0 900-900-900-900+250 900-900-900-900+300 900-900-900-900+350 900-900-900-900+400 900-900-900-900+450 900-900-900-900+500 900-900-900-900+600 900-900-900-900+700 900-900-900-900+750 900-900-900-900+800 900-900-900-900+900 900-900-900-900+1000 1000-1000-1000-1000+2/0 1000-1000-1000-1000+3/0 1000-1000-1000-1000+4/0 1000-1000-1000-1000+250 1000-1000-1000-1000+300 1000-1000-1000-1000+350 1000-1000-1000-1000+400 1000-1000-1000-1000+450 1000-1000-1000-1000+500 1000-1000-1000-1000+600 1000-1000-1000-1000+650 1000-1000-1000-1000+700 1000-1000-1000-1000+750 1000-1000-1000-1000+800 1000-1000-1000-1000+900 1000-1000-1000-1000+1000

800 800 800 800 800 800 800 800 800 800 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

937 937 937 937 937 937 937 937 937 937 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1059 1059 1059 1059 1059 1059 1059 1059 1059 1059 1059 1059 1059 1059 1059 1059

80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80

250 300 350 400 450 500 600 700 750 800 2/0 3/0 4/0 250 300 350 400 450 500 600 700 750 800 900 1000 2/0 3/0 4/0 250 300 350 400 450 500 600 650 700 750 800 900 1000

520 571 614 657 701 736 815 878 909 937 376 421 476 520 571 614 657 701 736 815 878 909 937 1000 1059 376 421 476 520 571 614 657 701 736 815 843 878 909 937 1000 1059

65 65 65 65 65 65 80 80 80 80 55 55 55 65 65 65 65 65 65 80 80 80 80 80 80 55 55 55 65 65 65 65 65 65 80 80 80 80 80 80 80

2744 2795 2795 2850 2850 2850 2906 2961 2961 2961 2807 2878 2902 2902 2957 2957 2957 3016 3016 3075 3075 3130 3130 3130 3130 2949 3024 3024 3047 3047 3106 3106 3106 3169 3228 3228 3228 3228 3228 3291 3291

3068 3119 3119 3174 3174 3174 3229 3284 3284 3284 3131 3202 3225 3225 3280 3280 3280 3339 3339 3398 3398 3454 3454 3454 3454 3272 3347 3347 3371 3371 3430 3430 3430 3493 3552 3552 3552 3552 3552 3615 3615

3703 3758 3803 3861 3906 3951 4054 4157 4203 4248 3977 4022 4066 4103 4158 4204 4251 4307 4353 4456 4549 4605 4650 4743 4835 4374 4420 4459 4500 4546 4602 4649 4695 4752 4856 4901 4948 4994 5039 5143 5236

4287 4348 4398 4460 4510 4559 4692 4803 4853 4901 3977 4022 4066 4103 4158 4204 4251 4307 4353 4456 4549 4605 4650 4743 4835 4374 4420 4459 4500 4546 4602 4649 4695 4752 4856 4901 4948 4994 5039 5143 5236

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

912 20180201

ARMORED CABLES

A800-04MC250 A800-04MC300 A800-04MC350 A800-04MC400 A800-04MC450 A800-04MC500 A800-04MC600 A800-04MC700 A800-04MC750 A800-04MC800 A900-04MC2/0 A900-04MC3/0 A900-04MC4/0 A900-04MC250 A900-04MC300 A900-04MC350 A900-04MC400 A900-04MC450 A900-04MC500 A900-04MC600 A900-04MC700 A900-04MC750 A900-04MC800 A900-04MC900 A900-04MC1000 A1000-04MC2/0 A1000-04MC3/0 A1000-04MC4/0 A1000-04MC250 A1000-04MC300 A1000-04MC350 A1000-04MC400 A1000-04MC450 A1000-04MC500 A1000-04MC600 A1000-04MC650 A1000-04MC700 A1000-04MC750 A1000-04MC800 A1000-04MC900 A1000-04MC1000

Size of Cable

ARMORED CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

PowerGuard® Armored 5kV-35kV Copper 3/C with Copper Ground Wire TR-XLPE Insulation Copper Tape Shield AIA PVC Jacket UL Type MV-105 or MC, AEIC CS8 Applications • Armored Medium-Voltage power cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods • Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not more than six feetApart • Installed in both exposedAnd concealed work, wet or dry locations, directly buried or embedded in concrete Construction Conductor: Class A or B Compressed concentric stranded copper conductor. Optional water-blocking. Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation Insulation: Extruded, unfilled Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in aNSI/ICEA S-94-649 Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. Metallic Shield:The metallic shield is flat uncoated 5-mil thick copper tape helically applied with minimum 20% overlap Ground Wire: Three bare copper ground wires placed at the interstice of the conductor. Fillers: Non hydroscopic fillers, forming a firm and cylindrical cable core. Binder Tape: A binder tape is applied to maintain core symmetry and mechanical stability. Armor: Aluminum Interlocked armor applied over the binder tape of the cable core Jacket: Black, sunlight resistant, flame retardant PVC jacket

NOTES: • The above dimensions are approximate and subject to normal manufacturing tolerances. • Ampacities are based on the following: Three Phase Operation In Duct (2011 NEC Table 310.60(C)(80): Three-conductor cable in plastic duct, direct-buried, 105°C conductor temperature, 20°C ambient temperature, earth RHO of 90°C-cm/Watt, and 100% load factor, and shields shortcircuited. Isolated in air (2011 NEC Table 310.60(C)(72)): Three-conductor cable, 105°C conductor temperature, and 40°C ambient temperature, and shields grounded at one point only. In Cable Tray: per 2011 NEC 392.80(B)(1)(b)3, for single conductor cables, sizes 1/0 AWG and larger, installed in a single layer in an uncovered table tray, with a maintained space of not less than one cable diameter between individual conductors, the ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table 310.60(C)(72) (Aluminum), “Isolated in air” values noted above. • Insulated cables are capable of operating at 105°C. However, the maximum operating temperature of the cable should be based on the maximum operating temperature of the cable accessories to be used.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

903 20140921

ARMORED CABLES

Specifications • AEIC CS8, Specifications for Shielded Power Cable, 5-46kV • ICEA S-93-639, 5-46 kV Shielded Power Cable • ICEA S-97-682, Utility Shielded Power Cable Rated 5-46kV • UL-1072 MV-105 • UL-1569, Metal Clad Cables • IEEE 383 Flame Test • For 105°C continuous, 140°C emergency, 250°C short-circuit operation. • UL MC-HLAvailable upon request

PowerGuard® Armored 5kV-35kV Copper 3/C with Copper Ground Wire TR-XLPE Insulation Copper Tape Shield AIA PVC Jacket UL Type MV-105 or MC, AEIC CS8

ARMORED CABLES

Item #

5kV Copper 100% 2-03AIAPC5GT105 1-03AIAPC5GT105 1/0-03AIAPC5GT105 2/0-03AIAPC5GT105 3/0-03AIAPC5GT105 4/0-03AIAPC5GT105 250-03AIAPC5GT105 350-03AIAPC5GT105 500-03AIAPC5GT105 750-03AIAPC5GT105 1000-03AIAPC5GT105 5kV Copper 133% 4-03AIAPC5UT105 2-03AIAPC5UT105 1-03AIAPC5UT105 1/0-03AIAPC5UT105 2/0-03AIAPC5UT105 3/0-03AIAPC5UT105 4/0-03AIAPC5UT105 250-03AIAPC5UT105 350-03AIAPC5UT105 500-03AIAPC5UT105 750-03AIAPC5UT105 1000-03AIAPC5UT105 8kV Copper 100% 4-03AIAPC8GT105 2-03AIAPC8GT105 1-03AIAPC8GT105 1/0-03AIAPC8GT105 2/0-03AIAPC8GT105 3/0-03AIAPC8GT105 4/0-03AIAPC8GT105 250-03AIAPC8GT105 350-03AIAPC8GT105 500-03AIAPC8GT105 750-03AIAPC8GT105 1000-03AIAPC8GT105

Size Insulation No. of Size of Conductor Insulation Insulation AWG Thickness Ground Ground Diameter Diameter Shield or (mil) Wires Wires (in) (in) (in) KCMIL

Overall Jacket (in)

Approx. Weight (lb/MFT)

Minimum Ampacity Bending 90°C Radius in Duct (in)

Ampacity 90°C inAir

2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

90 90 90 90 90 90 90 90 90 90 90

3 3 3 3 3 3 3 3 3 3 3

10 8 8 8 7 7 7 6 5 4 4

0.266 0.299 0.341 0.376 0.423 0.479 0.522 0.622 0.742 0.917 1.071

0.5 0.53 0.57 0.61 0.66 0.71 0.76 0.86 0.98 1.16 1.32

0.56 0.59 0.63 0.67 0.71 0.77 0.82 0.92 1.05 1.24 1.39

1.58 1.68 1.77 1.86 1.96 2.08 2.19 2.44 2.73 3.14 3.48

1585 1829 2111 2540 2951 3458 3914 5146 6898 9832 12524

12 12 13 14 14 15 16 18 20 23 25

145 165 190 220 250 285 315 380 460 570 645

154 180 205 240 280 320 355 440 545 685 790

4 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

115 115 115 115 115 115 115 115 115 115 115 115

3 3 3 3 3 3 3 3 3 3 3 3

10 10 8 8 8 7 7 7 6 5 4 4

0.215 0.266 0.299 0.341 0.376 0.423 0.479 0.522 0.622 0.742 0.917 1.071

0.5 0.55 0.58 0.62 0.66 0.71 0.76 0.81 0.91 1.03 1.21 1.37

0.56 0.61 0.64 0.68 0.72 0.76 0.82 0.87 0.97 1.1 1.29 1.44

1.58 1.71 1.78 1.89 1.97 2.07 2.19 2.3 2.54 2.84 3.25 3.59

1381 1740 1959 2299 2684 3102 3617 4080 5329 7101 10062 12776

12 12 13 14 14 15 16 17 18 20 23 26

110 145 165 190 220 250 285 315 380 460 570 645

115 154 180 205 240 280 320 355 440 545 685 790

4 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

115 115 115 115 115 115 115 115 115 115 115 115

3 3 3 3 3 3 3 3 3 3 3 3

10 10 8 8 8 7 7 7 6 5 4 4

0.215 0.266 0.299 0.341 0.376 0.423 0.479 0.522 0.622 0.742 0.917 1.071

0.5 0.55 0.58 0.62 0.66 0.71 0.76 0.81 0.91 1.03 1.21 1.37

0.56 0.61 0.64 0.68 0.72 0.76 0.82 0.87 0.97 1.1 1.29 1.44

1.58 1.71 1.78 1.89 1.97 2.07 2.19 2.3 2.54 2.84 3.25 3.59

1381 1740 1959 2299 2684 3102 3617 4080 5329 7101 10062 12776

12 12 13 14 14 15 16 17 18 20 23 26

125 160 185 210 235 270 305 335 400 485 585 660

135 185 210 240 275 315 360 400 490 600 745 860

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 903 20140921

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

PowerGuard® Armored 5kV-35kV Copper 3/C with Copper Ground Wire TR-XLPE Insulation Copper Tape Shield AIA PVC Jacket UL Type MV-105 or MC, AEIC CS8 Item #

8kV Copper 133% 2-03AIAPC8UT105 1-03AIAPC8UT105 1/0-03AIAPC8UT105 2/0-03AIAPC8UT105 3/0-03AIAPC8UT105 4/0-03AIAPC8UT105 250-03AIAPC8UT105 350-03AIAPC8UT105 500-03AIAPC8UT105 750-03AIAPC8UT105 1000-03AIAPC8UT105

Overall Jacket (in)

Approx. Weight (lb/MFT)

Minimum Ampacity Bending 90°C Radius in Duct (in)

Ampacity 90°C inAir

2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

140 140 140 140 140 140 140 140 140 140 140

3 3 3 3 3 3 3 3 3 3 3

10 8 8 8 7 7 7 6 5 4 4

0.266 0.299 0.341 0.376 0.423 0.479 0.522 0.622 0.742 0.917 1.071

0.6 0.63 0.67 0.71 0.76 0.81 0.86 0.96 1.08 1.26 1.42

0.66 0.69 0.73 0.77 0.81 0.87 0.92 1.02 1.15 1.34 1.49

1.82 1.91 2 2.08 2.18 2.3 2.44 2.65 2.95 3.36 3.69

1873 2149 2446 2836 3260 3783 4321 5519 7310 10299 13035

13 14 15 15 16 17 18 19 21 24 26

160 185 210 235 270 305 335 400 485 585 660

185 210 240 275 315 360 400 490 600 745 860

2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

175 175 175 175 175 175 175 175 175 175 175

3 3 3 3 3 3 3 3 3 3 3

10 8 8 8 7 7 7 6 5 4 4

0.266 0.299 0.341 0.376 0.423 0.479 0.522 0.622 0.742 0.917 1.071

0.67 0.7 0.74 0.78 0.83 0.88 0.93 1.03 1.15 1.33 1.49

0.73 0.76 0.8 0.84 0.88 0.94 0.99 1.1 1.22 1.41 1.58

1.99 2.06 2.15 2.23 2.33 2.48 2.59 2.84 3.1 3.51 3.88

2126 2358 2663 3060 3494 4097 4579 5864 7615 10644 13500

14 15 16 16 17 18 19 20 22 25 28

160 185 210 235 270 305 335 400 485 585 660

185 210 240 275 315 360 400 490 600 745 860

2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

220 220 220 220 220 220 220 220 220 220 220

3 3 3 3 3 3 3 3 3 3 3

10 8 8 8 7 7 7 6 5 4 4

0.266 0.299 0.341 0.376 0.423 0.479 0.522 0.622 0.742 0.917 1.071

0.76 0.79 0.83 0.87 0.92 0.97 1.02 1.12 1.24 1.42 1.58

0.82 0.85 0.89 0.93 0.97 1.03 1.09 1.19 1.31 1.5 1.67

2.19 2.26 2.35 2.45 2.55 2.68 2.82 3.03 3.31 3.71 4.07

2406 2647 2962 3437 3886 4437 4998 6247 8090 11107 14006

16 16 17 18 18 19 20 22 24 26 29

160 185 210 235 270 305 335 400 485 585 660

185 210 240 275 315 360 400 490 600 745 860

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

903 20140921

ARMORED CABLES

15kV Copper 100% 2-03AIAPC15GT105 1-03AIAPC15GT105 1/0-03AIAPC15GT105 2/0-03AIAPC15GT105 3/0-03AIAPC15GT105 4/0-03AIAPC15GT105 250-03AIAPC15GT105 350-03AIAPC15GT105 500-03AIAPC15GT105 750-03AIAPC15GT105 1000-03AIAPC15GT105 15kV Copper 133% 2-03AIAPC15UT105 1-03AIAPC15UT105 1/0-03AIAPC15UT105 2/0-03AIAPC15UT105 3/0-03AIAPC15UT105 4/0-03AIAPC15UT105 250-03AIAPC15UT105 350-03AIAPC15UT105 500-03AIAPC15UT105 750-03AIAPC15UT105 1000-03AIAPC15UT105

Size Insulation No. of Size of Conductor Insulation Insulation AWG Thickness Ground Ground Diameter Diameter Shield or (mil) Wires Wires (in) (in) (in) KCMIL

PowerGuard® Armored 5kV-35kV Copper 3/C with Copper Ground Wire TR-XLPE Insulation Copper Tape Shield AIA PVC Jacket UL Type MV-105 or MC, AEIC CS8 Item #

ARMORED CABLES

25kV Copper 100% 1-03AIAPC25GT105 1/0-03AIAPC25GT105 2/0-03AIAPC25GT105 3/0-03AIAPC25GT105 4/0-03AIAPC25GT105 250-03AIAPC25GT105 350-03AIAPC25GT105 500-03AIAPC25GT105 750-03AIAPC25GT105 25kV Copper 133% 1-03AIAPC25UT105 1/0-03AIAPC25UT105 2/0-03AIAPC25UT105 3/0-03AIAPC25UT105 4/0-03AIAPC25UT105 250-03AIAPC25UT105 350-03AIAPC25UT105 500-03AIAPC25UT105 35kV Copper 100% 1/0-03AIAPC35GT105 2/0-03AIAPC35GT105 3/0-03AIAPC35GT105 4/0-03AIAPC35GT105 250-03AIAPC35GT105 350-03AIAPC35GT105 500-03AIAPC35GT105 35kV Copper 133% 1/0-03AIAPC35UT105 2/0-03AIAPC35UT105 3/0-03AIAPC35UT105 4/0-03AIAPC35UT105 250-03AIAPC35UT105 350-03AIAPC35UT105

Size Insulation No. of Size of Conductor Insulation Insulation AWG Thickness Ground Ground Diameter Diameter Shield or (mil) Wires Wires (in) (in) (in) KCMIL

Overall Jacket (in)

Approx. Weight (lb/MFT)

Minimum Ampacity Bending 90°C Radius in Duct (in)

Ampacity 90°C in Air

1 1/0 2/0 3/0 4/0 250 350 500 750

260 260 260 260 260 260 260 260 260

3 3 3 3 3 3 3 3 3

8 8 8 7 7 7 6 5 4

0.299 0.341 0.376 0.423 0.479 0.522 0.622 0.742 0.917

0.87 0.91 0.95 1 1.05 1.1 1.2 1.32 1.5

0.93 0.97 1.01 1.07 1.13 1.17 1.27 1.39 1.59

2.46 2.55 2.63 2.76 2.88 2.99 3.22 3.48 3.91

2991 3319 3735 4260 4827 5334 6666 8480 11628

18 18 19 20 21 21 23 25 28

185 210 235 270 305 335 400 485 585

210 240 275 315 360 400 490 600 745

1 1/0 2/0 3/0 4/0 250 350 500

345 345 345 345 345 345 345 345

3 3 3 3 3 3 3 3

8 8 8 7 7 7 6 5

0.299 0.341 0.376 0.423 0.479 0.522 0.622 0.742

0.98 1.09 1.12 1.17 1.23 1.27 1.37 1.49

1.04 1.16 1.2 1.24 1.3 1.35 1.45 1.58

2.68 2.96 3.04 3.14 3.28 3.38 3.6 3.89

3326 4082 4517 5002 5658 6192 7516 9479

19 21 22 22 23 24 26 28

185 210 235 270 305 335 400 485

210 240 275 315 360 400 490 600

1/0 2/0 3/0 4/0 250 350 500

345 345 345 345 345 345 345

3 3 3 3 3 3 3

8 8 7 7 7 6 5

0.341 0.376 0.423 0.479 0.522 0.622 0.742

1.09 1.12 1.17 1.23 1.27 1.37 1.49

1.16 1.2 1.24 1.3 1.35 1.45 1.58

2.96 3.04 3.14 3.28 3.38 3.6 3.89

4082 4517 5002 5658 6192 7516 9479

21 22 22 23 24 26 28

210 235 270 305 335 400 485

240 275 315 360 400 490 600

1/0 2/0 3/0 4/0 250 350

420 420 420 420 420 420

3 3 3 3 3 3

8 8 7 7 7 6

0.341 0.376 0.423 0.479 0.522 0.622

1.24 1.27 1.32 1.38 1.42 1.52

1.31 1.35 1.39 1.45 1.5 1.61

3.3 3.38 3.48 3.6 3.71 3.96

4818 5269 5776 6397 6951 8409

24 24 25 26 26 28

210 235 270 305 335 400

240 275 315 360 400 490

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 903 201401916

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

PowerGuard® Armored 5kV-35kV Aluminum 3/C with Copper Ground Wire TR-XLPE Insulation Copper Tape Shield AIA PVC Jacket UL Type MV-105 or MC,AEIC CS8 Applications • Armored Medium-Voltage power cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods • Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not more than six feet apart • Installed in both exposed and concealed work, wet or dry locations, directly buried or embedded in concrete Construction Conductor: Class A or B Compressed concentric stranded aluminum alloy 1350 per ASTM B 231. Stranded conductors are water-blocked with conductor filling compound. Conductor Shield: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation Insulation: Extruded, unfilled Tree-Retardant Cross-linked Polyethylene (TRXLPE) as defined in ANSI/ICEA S-94-649 Insulation Shield: Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping. Metallic Shield:The metallic shield is flat uncoated 5-mil thick copper tape helically applied with minimum 20% overlap Ground Wire: Three bare copper ground wires placed at the interstice of the conductor. Fillers: Non hydroscopic fillers, forming a firm and cylindrical cable core. Binder Tape: A binder tape is applied to maintain core symmetry and mechanical stability. Armor: Aluminum Interlocked armor applied over the binder tape of the cable core Jacket: Black, sunlight resistant, flame retardant PVC jacket

NOTES: • The above dimensions are approximate and subject to normal manufacturing tolerances. • Ampacities are based on the following: Three Phase Operation In Duct (2011 NEC Table 310.60(C)(80): Three-conductor cable in plastic duct, direct-buried, 105°C conductor temperature, 20°C ambient temperature, earth RHO of 90°C-cm/Watt, and 100% load factor, and shields shortcircuited. Isolated in air (2011 NEC Table 310.60(C)(72)): Three-conductor cable, 105°C conductor temperature, and 40°C ambient temperature, and shields grounded at one point only. In Cable Tray: per 2011 NEC 392.80(B)(1)(b)3, for single conductor cables, sizes 1/0AWG and larger, installed in a single layer in an uncovered table tray, with a maintained space of not less than one cable diameter between individual conductors, the ampacities shall not exceed the allowable ampacities stated in 2011 NEC Table 310.60(C)(72) (Aluminum), “Isolated in air” values noted above. • Insulated cables are capable of operating at 105°C. However, the maximum operating temperature of the cable should be based on the maximum operating temperature of the cable accessories to be used.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

904 20140921

ARMORED CABLES

Specifications • AEIC CS8, Specifications for Shielded Power Cable, 5-46kV • ICEA S-93-639, 5-46 kV Shielded Power Cable • ICEA S-97-682, Utility Shielded Power Cable Rated 5-46 kV • UL-1072 MV-105 • UL-1569, Metal Clad Cables • IEEE 383 Flame Test • For 105°C continuous, 140°C emergency, 250°C short-circuit operation. • UL MC-HL available upon request

PowerGuard® Armored 5kV-35kVAluminum 3/C with Copper Ground Wire TR-XLPE Insulation Copper Tape Shield AIA PVC Jacket UL Type MV-105 or MC, AEIC CS8

ARMORED CABLES

Item #

5kVAluminum 100% A4-03AIAPC5GT105 A2-03AIAPC5GT105 A1-03AIAPC5GT105 A1/0-03AIAPC5GT105 A2/0-03AIAPC5GT105 A3/0-03AIAPC5GT105 A4/0-03AIAPC5GT105 A250-03AIAPC5GT105 A350-03AIAPC5GT105 A500-03AIAPC5GT105 A750-03AIAPC5GT105 A1000-03AIAPC5GT105 5kVAluminum 133% A4-03AIAPC5UT105 A2-03AIAPC5UT105 A1-03AIAPC5UT105 A1/0-03AIAPC5UT105 A2/0-03AIAPC5UT105 A3/0-03AIAPC5UT105 A4/0-03AIAPC5UT105 A250-03AIAPC5UT105 A350-03AIAPC5UT105 A500-03AIAPC5UT105 A750-03AIAPC5UT105 A1000-03AIAPC5UT105 8kVAluminum 100% A4-03AIAPC8GT105 A2-03AIAPC8GT105 A1-03AIAPC8GT105 A1/0-03AIAPC8GT105 A2/0-03AIAPC8GT105 A3/0-03AIAPC8GT105 A4/0-03AIAPC8GT105 A250-03AIAPC8GT105 A350-03AIAPC8GT105 A500-03AIAPC8GT105 A750-03AIAPC8GT105 A1000-03AIAPC8GT105

Size Insulation No. of Size of Conductor Insulation Insulation AWG Thickness Ground Ground Diameter Diameter Shield or (mil) Wires Wires (in) (in) (in) KCMIL

Overall Jacket (in)

Approx. Weight (lb/MFT)

Minimum Ampacity Bending 90°C Radius in Duct (in)

Ampacity 90°C in Air

4 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

90 90 90 90 90 90 90 90 90 90 90 90

3 3 3 3 3 3 3 3 3 3 3 3

10 10 10 10 8 8 8 8 7 6 5 4

0.215 0.266 0.299 0.336 0.379 0.423 0.479 0.522 0.622 0.742 0.917 1.071

0.45 0.5 0.53 0.57 0.61 0.66 0.71 0.76 0.86 0.98 1.16 1.32

0.51 0.56 0.59 0.63 0.67 0.71 0.77 0.82 0.92 1.05 1.24 1.39

1.47 1.58 1.68 1.75 1.87 1.96 2.08 2.19 2.44 2.73 3.14 3.48

1001 1165 1298 1431 1698 1887 2121 2338 2927 3734 4987 6177

11 12 12 13 14 14 15 16 18 20 23 25

86 110 130 150 170 195 220 245 310 365 460 535

90 120 140 160 185 215 250 280 345 430 550 650

4 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

115 115 115 115 115 115 115 115 115 115 115 115

3 3 3 3 3 3 3 3 3 3 3 3

10 10 10 10 8 8 8 8 7 6 5 4

0.215 0.266 0.299 0.336 0.379 0.423 0.479 0.522 0.622 0.742 0.917 1.071

0.5 0.55 0.58 0.62 0.66 0.71 0.76 0.81 0.91 1.03 1.21 1.37

0.56 0.61 0.64 0.68 0.72 0.76 0.82 0.87 0.97 1.1 1.29 1.44

1.58 1.71 1.78 1.88 1.98 2.07 2.19 2.3 2.54 2.84 3.25 3.59

1117 1321 1429 1619 1843 2038 2280 2504 3110 3937 5218 6429

12 12 13 14 14 15 16 17 18 20 23 26

86 110 130 150 170 195 220 245 310 365 460 535

90 120 140 160 185 215 250 280 345 430 550 650

4 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

115 115 115 115 115 115 115 115 115 115 115 115

3 3 3 3 3 3 3 3 3 3 3 3

10 10 10 10 8 8 8 8 7 6 5 4

0.215 0.266 0.299 0.336 0.379 0.423 0.479 0.522 0.622 0.742 0.917 1.071

0.5 0.55 0.58 0.62 0.66 0.71 0.76 0.81 0.91 1.03 1.21 1.37

0.56 0.61 0.64 0.68 0.72 0.76 0.82 0.87 0.97 1.1 1.29 1.44

1.58 1.71 1.78 1.88 1.98 2.07 2.19 2.3 2.54 2.84 3.25 3.59

1117 1321 1429 1619 1843 2038 2280 2504 3110 3937 5218 6429

12 12 13 14 14 15 16 17 18 20 23 26

96 125 145 165 185 210 240 265 315 385 475 545

105 145 165 185 215 245 285 315 385 475 600 705

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 904 20140921

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

PowerGuard® Armored 5kV-35kV Aluminum 3/C with Copper Ground Wire TR-XLPE Insulation Copper Tape Shield AIA PVC Jacket UL Type MV-105 or MC, AEIC CS8 Item #

8kVAluminum 133% A2-03AIAPC8UT105 A1-03AIAPC8UT105 A1/0-03AIAPC8UT105 A2/0-03AIAPC8UT105 A3/0-03AIAPC8UT105 A4/0-03AIAPC8UT105 A250-03AIAPC8UT105 A350-03AIAPC8UT105 A500-03AIAPC8UT105 A750-03AIAPC8UT105 A1000-03AIAPC8UT105

Size Insulation No. of Size of Conductor Insulation Insulation AWG Thickness Ground Ground Diameter Diameter Shield or (mil) Wires Wires (in) (in) (in) KCMIL 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

Approx. Weight (lb/MFT)

Minimum Ampacity Bending 90°C Radius in Duct (in)

Ampacity 90°C in Air

140 140 140 140 140 140 140 140 140 140 140

3 3 3 3 3 3 3 3 3 3 3

10 10 10 8 8 8 8 7 6 5 4

0.266 0.299 0.336 0.379 0.423 0.479 0.522 0.622 0.742 0.917 1.071

0.6 0.63 0.67 0.71 0.76 0.81 0.86 0.96 1.08 1.26 1.42

0.66 0.69 0.73 0.77 0.81 0.87 0.92 1.02 1.15 1.34 1.49

1.82 1.91 1.99 2.08 2.18 2.3 2.44 2.65 2.95 3.36 3.69

1454 1619 1764 1995 2196 2446 2745 3300 4146 5455 6689

13 14 14 15 16 17 18 19 21 24 26

125 145 165 185 210 240 265 315 385 475 545

145 165 185 215 245 285 315 385 475 600 705

175 175 175 175 175 175 175 175 175 175 175

3 3 3 3 3 3 3 3 3 3 3

10 10 10 8 8 8 8 7 6 5 4

0.266 0.299 0.336 0.379 0.423 0.479 0.522 0.622 0.742 0.917 1.071

0.67 0.7 0.74 0.78 0.83 0.88 0.93 1.03 1.15 1.33 1.49

0.73 0.76 0.8 0.84 0.88 0.94 0.99 1.1 1.22 1.41 1.58

1.99 2.06 2.14 2.24 2.33 2.48 2.59 2.84 3.1 3.51 3.88

1706 1828 1980 2219 2430 2760 3003 3645 4451 5799 7153

14 15 15 16 17 18 19 20 22 25 28

125 145 165 185 210 240 265 315 385 475 545

145 165 185 215 245 285 315 385 475 600 705

220 220 220 220 220 220 220 220 220 220 220

3 3 3 3 3 3 3 3 3 3 3

10 10 10 8 8 8 8 7 6 5 4

0.266 0.299 0.336 0.379 0.423 0.479 0.522 0.622 0.742 0.917 1.071

0.76 0.79 0.83 0.87 0.92 0.97 1.02 1.12 1.24 1.42 1.58

0.82 0.85 0.89 0.93 0.97 1.03 1.09 1.19 1.31 1.5 1.67

2.19 2.26 2.34 2.46 2.55 2.68 2.82 3.03 3.31 3.71 4.07

1987 2116 2279 2597 2821 3100 3422 4027 4926 6262 7659

16 16 17 18 18 19 20 22 24 26 29

125 145 165 185 210 240 265 315 385 475 545

145 165 185 215 245 285 315 385 475 600 705

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

904 20140921

ARMORED CABLES

15kVAluminum 100% A2-03AIAPC15GT105 2 A1-03AIAPC15GT105 1 A1/0-03AIAPC15GT105 1/0 A2/0-03AIAPC15GT105 2/0 A3/0-03AIAPC15GT105 3/0 A4/0-03AIAPC15GT105 4/0 A250-03AIAPC15GT105 250 A350-03AIAPC15GT105 350 A500-03AIAPC15GT105 500 A750-03AIAPC15GT105 750 A1000-03AIAPC15GT1051000 15kVAluminum 133% A2-03AIAPC15UT105 2 A1-03AIAPC15UT105 1 A1/0-03AIAPC15UT105 1/0 A2/0-03AIAPC15UT105 2/0 A3/0-03AIAPC15UT105 3/0 A4/0-03AIAPC15UT105 4/0 A250-03AIAPC15UT105 250 A350-03AIAPC15UT105 350 A500-03AIAPC15UT105 500 A750-03AIAPC15UT105 750 A1000-03AIAPC15UT1051000

Overall Jacket (in)

PowerGuard® Armored 5kV-35kV Aluminum 3/C with Copper Ground Wire TR-XLPE Insulation Copper Tape Shield AIA PVC Jacket UL Type MV-105 or MC, AEIC CS8 Item #

ARMORED CABLES

25kVAluminum 100% A1-03AIAPC25GT105 A1/0-03AIAPC25GT105 A2/0-03AIAPC25GT105 A3/0-03AIAPC25GT105 A4/0-03AIAPC25GT105 A250-03AIAPC25GT105 A350-03AIAPC25GT105 A500-03AIAPC25GT105 A750-03AIAPC25GT105 25kVAluminum 133% A1/0-03AIAPC25UT105 A2/0-03AIAPC25UT105 A3/0-03AIAPC25UT105 A4/0-03AIAPC25UT105 A250-03AIAPC25UT105 A350-03AIAPC25UT105 A500-03AIAPC25UT105 35kVAluminum 100% A1/0-03AIAPC35GT105 A2/0-03AIAPC35GT105 A3/0-03AIAPC35GT105 A4/0-03AIAPC35GT105 A250-03AIAPC35GT105 A350-03AIAPC35GT105 A500-03AIAPC35GT105 35kVAluminum 133% A1/0-03AIAPC35UT105 A2/0-03AIAPC35UT105 A3/0-03AIAPC35UT105 A4/0-03AIAPC35UT105 A250-03AIAPC35UT105 A350-03AIAPC35UT105

Size Insulation No. of Size of Conductor Insulation Insulation AWG Thickness Ground Ground Diameter Diameter Shield or (mil) Wires Wires (in) (in) (in) KCMIL

Overall Jacket (in)

Approx. Weight (lb/MFT)

Minimum Ampacity Bending 90°C Radius in Duct (in)

Ampacity 90°C inAir

1 1/0 2/0 3/0 4/0 250 350 500 750

260 260 260 260 260 260 260 260 260

3 3 3 3 3 3 3 3 3

10 10 8 8 8 8 7 6 5

0.299 0.336 0.379 0.423 0.479 0.522 0.622 0.742 0.917

0.87 0.91 0.95 1 1.05 1.1 1.2 1.32 1.5

0.93 0.97 1.01 1.07 1.13 1.17 1.27 1.39 1.59

2.46 2.54 2.63 2.76 2.88 2.99 3.22 3.48 3.91

2461 2634 2896 3196 3489 3759 4447 5316 6783

18 18 19 20 21 21 23 25 28

145 165 185 210 240 265 315 385 475

165 185 215 245 285 315 385 475 600

1/0 2/0 3/0 4/0 250 350 500

345 345 345 345 345 345 345

3 3 3 3 3 3 3

10 8 8 8 8 7 6

0.336 0.379 0.423 0.479 0.522 0.622 0.742

1.08 1.13 1.17 1.23 1.27 1.37 1.49

1.16 1.2 1.24 1.3 1.35 1.45 1.58

2.95 3.04 3.14 3.28 3.38 3.6 3.89

3395 3680 3938 4321 4616 5297 6315

21 22 22 23 24 26 28

165 185 210 240 265 315 385

185 215 245 285 315 385 475

1/0 2/0 3/0 4/0 250 350 500

345 345 345 345 345 345 345

3 3 3 3 3 3 3

10 8 8 8 8 7 6

0.336 0.379 0.423 0.479 0.522 0.622 0.742

1.08 1.13 1.17 1.23 1.27 1.37 1.49

1.16 1.2 1.24 1.3 1.35 1.45 1.58

2.95 3.04 3.14 3.28 3.38 3.6 3.89

3395 3680 3938 4321 4616 5297 6315

21 22 22 23 24 26 28

165 185 210 240 265 315 385

185 215 245 285 315 385 475

1/0 2/0 3/0 4/0 250 350

420 420 420 420 420 420

3 3 3 3 3 3

10 8 8 8 8 7

0.336 0.379 0.423 0.479 0.522 0.622

1.23 1.28 1.32 1.38 1.42 1.52

1.31 1.35 1.39 1.45 1.5 1.61

3.29 3.39 3.48 3.6 3.71 3.96

4128 4433 4712 5059 5375 6190

24 24 25 26 26 28

165 185 210 240 265 315

185 215 245 285 315 385

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 904 20140921

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Continuously Corrugated Welded Armored Power Cable FR-XLP Insulation (XHHW-2), 600V/1kV Type MC-HL 1/C Application All cables produced to this specification are recognized by the NECAs 600 Volt Type MC-HL and are suitable for use as described in the code. The conductor temperatures are rated for continuous operation of 90°C, for emergency overload of 130°C and for short circuit of 250°C. The cables meet the requirements for application in NEC Class I , Class II and Class III, Div. 1 and 2, Hazardous Locations covered under NEC articles 501, 502 and 503. The cables are intended for use in industrial applications where aluminum armor protection is necessary. The continuously welded sheath serves to provide a completely moisture impervious barrier for the core as well as providing superior electro static shielding characteristics. The cables may be used in wet or dry applications, installed in racks, trays or aerially. These cables have an overall jacket and can be direct buried in earth and buried in concrete. Three conductor cables are manufactured in accordance with industry accepted practice of using three symmetrically placed grounds making them advantageous for use in pulse-width modulated cables and variable frequency drive applications.

Specifications • National Fire ProtectionAssociation (NFPA 70) National Electric Code (NEC) • UL 1569 Metal Clad Cables • UL 44 Thermoset-Insulated WiresAnd Cables • ICEA S-95-658/NEMA WC70 Nonshielded 0-2kV Cables • IEEE 1202 - Flame Testing of Cable for use in Cable Tray in Industrial and Commercial Occupancies (70,000 BTU) • ICEA T-29-520 Vertical Cable Tray Flame Tests (210,000 BTU) • Conforms to Standard ICEA S-95-658/NEMA WC70 Nonshielded 0-2KV Cables. • Conductors conforms to Standard UL 44 Thermoset-Insulated Wires and Cables. • Listed by ULAs Type MC-HL per Standard UL 1569 Metal-Clad Cables. • Listed by ULAs Sunlight Resistant, for Direct Burial, For CT Use and IEEE 1202. Options • Custom ground sizes • CPE jacket. Notes **Based on single cable in uncovered cable tray at 30°C ambient temperature per NEC. For other installations refer to the NEC.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, AAmerican Wire Group, Inc.

905 20160220

ARMORED CABLES

Construction This specification covers single and multi-conductor power cables insulated with flame retardant crosslinked polyethylene (XLP). The insulated conductors cabled with a ground wire or wires, and the assembly are encased in a moisture impervious continuously welded corrugated aluminum armor, and covered with a protective jacket overall. Three conductor type cables are constructed for VFD applications. Conductors - The conductors consist of uncoated soft, copper strands meeting the requirements ofASTM B3. Unless otherwise specified the conductors are supplied as compact round per ASTM B496. Insulation - The insulation is flame-retardant crosslinked polyethylene (XHHW-2) extruded concentrically over the conductor to the wall thickness for Type XHHW-2 as specified in the relevant governing specification. Conductor Coding - Phase identification is provided by number code on each insulated conductor. Ground Wire - Three stranded bare copper ground wires located in each of the outer interstices for 3 conductor cables, one in one of the interstices for 2 or 4 conductor cables, or helically applied concentric wires for single conductor cables. The total ground wire cross section in all cases meets the minimum UL requirements for ground size. Assembly - Conductors and ground wire are cabled together with a left hand lay and suitable fillers make the cable round. a binder tape is applied. Armor - Over the taped assembly there is continuously welded corrugated aluminum armor. Jacket -A protective sunlight and ozone resistant PVC or low smoke halogen free (LSHF) polyolefin jacket is extruded for a tight fit over the interlocked armor.

Continuously Corrugated Welded Armored Power Cable FR-XLP Insulation (XHHW-2), 600V/1kV Type MC-HL 1/C Item #

Conductor No. of Strands

1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 1000

19 19 19 19 37 37 37 37 37 61 61 61

Conductor Nominal O.D. (in) 0.34 0.38 0.42 0.48 0.52 0.57 0.62 0.66 0.74 0.81 0.91 1.12

Insulation (mil)

Jacket (mil)

55 55 55 55 65 65 65 65 65 80 80 80

50 50 50 50 50 50 50 50 50 60 60 60

No. xAWG Copper Ground Wires 10 x 14 10 x 14 13 x 14 16 x 14 10 x 12 13 x 12 13 x 12 16 x 12 16 x 12 16 x 12 13 x 10 16 x 10

Approximate O.D. (in)

Ampacity** 90°C

1.19 1.23 1.28 1.33 1.44 1.44 1.44 1.44 1.44 1.57 1.77 1.87

170 195 225 260 295 325 370 400 455 585 660 790

Approximate Net Weight (lb/MFT) 800 900 1065 1255 1440 1660 1820 2040 2360 2735 3375 4305

ARMORED CABLES

CWCAPC-1-1/0 CWCAPC-1-2/0 CWCAPC-1-3/0 CWCAPC-1-4/0 CWCAPC-1-250 CWCAPC-1-300 CWCAPC-1-350 CWCAPC-1-400 CWCAPC-1-500 CWCAPC-1-600 CWCAPC-1-750 CWCAPC-1-1000*

Conductor Size (AWG/kcmil)

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 905 20160220

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Continuously Corrugated Welded Armored Power Cable FR-XLP Insulation (XHHW-2), 600V/1kV Type MC-HL 2/C Application All cables produced to this specification are recognized by the NECAs 600 Volt Type MC-HL and are suitable for use as described in the code. The conductor temperatures are rated for continuous operation of 90°C, for emergency overload of 130°C and for short circuit of 250°C. The cables meet the requirements for application in NEC Class I, Class II and Class III, Div. 1 and 2, Hazardous Locations covered under NEC articles 501, 502 and 503. The cables are intended for use in industrial applications where aluminum armor protection is necessary. The continuously welded sheath serves to provide a completely moisture impervious barrier for the core as well as providing superior electro static shielding characteristics. The cables may be used in wet or dry applications, installed in racks, trays or aerially. These cables have an overall jacket and can be direct buried in earth and buried in concrete. Three conductor cables are manufactured in accordance with industry accepted practice of using three symmetrically placed grounds making them advantageous for use in pulse-width modulated cables and variable frequency drive applications.

Copper Conductor XLP Insulation Filters Binder Tape CorrugatedArmor PVC Jacket

Specifications • National Fire Protection Association (NFPA 70) National Electric Code (NEC) • UL 1569 Metal Clad Cables • UL 44 Thermoset-Insulated Wires and Cables • ICEA S-95-658/NEMA WC70 Nonshielded 0-2kV Cables • IEEE 1202 - Flame Testing of Cable for use in Cable Tray in Industrial and Commercial Occupancies (70,000 BTU) • ICEA T-29-520 Vertical Cable Tray Flame Tests (210,000 BTU) • Conforms to Standard ICEA S-95-658/NEMA WC70 Nonshielded 0-2KV Cables. • Conductors conforms to Standard UL 44 Thermoset-Insulated Wires and Cables. • Listed by ULAs Type MC-HL per Standard UL 1569 Metal-Clad Cables. • Listed by ULAs Sunlight Resistant, for Direct Burial, For CT Use and IEEE 1202. Options • Custom ground sizes • CPE jacket. Notes **Based on single cable in uncovered cable tray at 30°C ambient temperature per NEC. For other installations refer to the NEC.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, AAmerican Wire Group, Inc.

906 20160220

ARMORED CABLES

Copper Ground Wire

Construction This specification covers single and multi-conductor power cables insulated with flame retardant crosslinked polyethylene (XLP). The insulated conductors cabled with a ground wire or wires, and the assembly are encased in a moisture impervious continuously welded corrugated aluminum armor, and covered with a protective jacket overall. Three conductor type cables are constructed for VFD applications. Conductors - The conductors consist of uncoated soft, copper strands meeting the requirements ofASTM B3. Unless otherwise specified the conductors are supplied as compact round perASTM B496. Insulation - The insulation is flame-retardant crosslinked polyethylene (XHHW-2) extruded concentrically over the conductor to the wall thickness for Type XHHW-2 as specified in the relevant governing specification. Conductor Coding - Phase identification is provided by number code on each insulated conductor. Ground Wire - Three stranded bare copper ground wires located in each of the outer interstices for 3 conductor cables, one in one of the interstices for 2 or 4 conductor cables, or helically applied concentric wires for single conductor cables. The total ground wire cross section in all cases meets the minimum UL requirements for ground size. Assembly - Conductors and ground wire are cabled together with a left hand lay and suitable fillers make the cable round. A binder tape is applied. Armor - Over the taped assembly there is continuously welded corrugated aluminum armor. Jacket - A protective sunlight and ozone resistant PVC or low smoke halogen free (LSHF) polyolefin jacket is extruded for a tight fit over the interlocked armor.

Continuously Corrugated Welded Armored Power Cable FR-XLP Insulation (XHHW-2), 600V/1kV Type MC-HL 2/C Item #

Conductor No. of Strands

8* 6* 4* 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 750

7 7 7 7 19 19 19 19 19+ 37 37 37 37 37 61

Conductor Nominal O.D. (in) 0.14 0.18 0.23 0.27 0.30 0.34 0.38 0.42 0.48 0.52 0.57 0.62 0.68 0.74 0.91

Insulation (mil)

Jacket (mil)

45 45 45 45 55 55 55 55 55 65 65 65 65 65 80

50 50 50 50 50 50 50 50 60 60 60 60 60 60 75

No. xAWG Copper Ground Wires 10 6 8 6 6 6 6 4 4 4 3 3 3 2 1

Approximate O.D. (in)

Ampacity** 90°C

0.86 0.96 1.06 1.16 1.44 1.44 1.44 1.57 1.77 1.77 1.87 2.06 2.06 2.28 2.79

55 75 95 130 150 170 195 225 260 290 320 350 380 430 535

Approximate Net Weight (lb/MFT) 380 500 640 865 1110 1265 1460 1790 2155 2450 2865 3265 3615 4410 6505

ARMORED CABLES

CWCAPC-2-8* CWCAPC-2-6* CWCAPC-2-4* CWCAPC-2-2 CWCAPC-2-1 CWCAPC-2-1/0 CWCAPC-2-2/0 CWCAPC-2-3/0 CWCAPC-2-4/0 CWCAPC-2-250 CWCAPC-2-300 CWCAPC-2-350 CWCAPC-2-400 CWCAPC-2-500 CWCAPC-2-750

Conductor Size (AWG/kcmil)

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 906 20160220

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Continuously Corrugated Welded Armored Power Cable FR-XLP Insulation (XHHW-2), 600V/1kV Type MC-HL 3/C Application All cables produced to this specification are recognized by the NEC as 600 Volt Type MC-HL and are suitable for use as described in the code. The conductor temperatures are rated for continuous operation of 90°C, for emergency overload of 130°C and for short circuit of 250°C. The cables meet the requirements for application in NEC Class I, Class II and Class III, Div. 1 and 2, Hazardous Locations covered under NEC articles 501, 502 and 503. The cables are intended for use in industrial applications where aluminum armor protection is necessary. The continuously welded sheath serves to provide a completely moisture impervious barrier for the core as well as providing superior electro static shielding characteristics. The cables may be used in wet or dry applications, installed in racks, trays or aerially. These cables have an overall jacket and can be direct buried in earth and buried in concrete. Three conductor cables are manufactured in accordance with industry accepted practice of using three symmetrically placed grounds making them advantageous for use in pulse-width modulated cables and variable frequency drive applications.

Copper Conductor XLP Insulation Filters Binder Tape CorrugatedArmor PVC Jacket

Specifications • National Fire Protection Association (NFPA 70) National Electric Code (NEC) • UL 1569 Metal Clad Cables • UL 44 Thermoset-Insulated Wires and Cables • ICEA S-95-658/NEMA WC70 Nonshielded 0-2kV Cables • IEEE 1202 - Flame Testing of Cable for use in Cable Tray in Industrial and Commercial Occupancies (70,000 BTU) • ICEA T-29-520 Vertical Cable Tray Flame Tests (210,000 BTU) • Conforms to Standard ICEA S-95-658/NEMA WC70 Nonshielded 0-2KV Cables. • Conductors conforms to Standard UL 44 Thermoset-Insulated Wires and Cables. • Listed by ULAs Type MC-HL per Standard UL 1569 Metal-Clad Cables. • Listed by ULAs Sunlight Resistant, for Direct Burial, For CT Use and IEEE 1202. Options • Custom ground sizes • CPE jacket. Notes **Based on single cable in uncovered cable tray at 30°C ambient temperature per NEC. For other installations refer to the NEC.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, AAmerican Wire Group, Inc.

907 20160220

ARMORED CABLES

Copper Ground Wire

Construction This specification covers single and multi-conductor power cables insulated with flame retardant crosslinked polyethylene (XLP). The insulated conductors cabled with a ground wire or wires, and the assembly are encased in a moisture impervious continuously welded corrugated aluminum armor, and covered with a protective jacket overall. Three conductor type cables are constructed for VFD applications. Conductors - The conductors consist of uncoated soft, copper strands meeting the requirements of ASTM B3. Unless otherwise specified the conductors are supplied as compact round per ASTM B496. Insulation - The insulation is flame-retardant crosslinked polyethylene (XHHW-2) extruded concentrically over the conductor to the wall thickness for Type XHHW-2 as specified in the relevant governing specification. Conductor Coding - Phase identification is provided by number code on each insulated conductor. Ground Wire - Three stranded bare copper ground wires located in each of the outer interstices for 3 conductor cables, one in one of the interstices for 2 or 4 conductor cables, or helically applied concentric wires for single conductor cables. The total ground wire cross section in all cases meets the minimum UL requirements for ground size. Assembly - Conductors and ground wire are cabled together with a left hand lay and suitable fillers make the cable round. a binder tape is applied. Armor - Over the taped assembly there is continuously welded corrugated aluminum armor. Jacket - A protective sunlight and ozone resistant PVC or low smoke halogen free (LSHF) polyolefin jacket is extruded for a tight fit over the interlocked armor.

Continuously Corrugated Welded Armored Power Cable FR-XLP Insulation (XHHW-2), 600V/1kV Type MC-HL 3/C Item #

Conductor No. of Strands

8* 6* 4* 2 1 1/0 2/0 3/0 4/0 250 350 400 500 750 1000*

7 7 7 7 19 19 19 19 19 37 37 37 37 61 61

Conductor Nominal O.D. (in) 0.14 0.18 0.23 0.27 0.30 0.34 0.38 0.42 0.48 0.52 0.62 0.66 0.74 0.91 1.12

Insulation (mil)

Jacket (mil)

45 45 45 45 55 55 55 55 55 65 65 65 65 80 80

50 50 50 50 50 50 50 50 60 60 60 60 75 75 85

No. xAWG Copper Ground Wires 3 x 14 3 x 12 3 x 12 3 x 10 3 x 10 3 x 10 3 x 10 3x8 3x8 3x8 3x6 3x6 3x6 3x4 3x4

Approximate O.D. (in)

Ampacity** 90°C

0.91 1.01 1.11 1.44 1.44 1.44 1.57 1.57 1.77 1.87 2.28 2.28 2.58 3.08 3.33

55 75 97 130 150 170 195 225 260 290 350 375 430 535 615

Approximate Net Weight (lb/MFT) 465 615 810 1205 1415 1645 1965 2375 2880 3340 4520 5070 6260 9100 11965

ARMORED CABLES

CWCAPC-3-8* CWCAPC-3-6* CWCAPC-3-4* CWCAPC-3-2 CWCAPC-3-1 CWCAPC-3-1/0 CWCAPC-3-2/0 CWCAPC-3-3/0 CWCAPC-3-4/0 CWCAPC-3-250 CWCAPC-3-350 CWCAPC-3-400 CWCAPC-3-500 CWCAPC-3-750 CWCAPC-3-1000*

Conductor Size (AWG/kcmil)

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 907 20160220

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Continuously Corrugated Welded Armored Power Cable FR-XLP Insulation (XHHW-2), 600V/1kV Type MC-HL 4/C Application All cables produced to this specification are recognized by the NECAs 600 Volt Type MC-HL and are suitable for use as described in the code. The conductor temperatures are rated for continuous operation of 90°C, for emergency overload of 130°C and for short circuit of 250°C. The cables meet the requirements for application in NEC Class I, Class II and Class III, Div. 1 and 2, Hazardous Locations covered under NEC articles 501, 502 and 503. The cables are intended for use in industrial applications where aluminum armor protection is necessary. The continuously welded sheath serves to provide a completely moisture impervious barrier for the core as well as providing superior electro static shielding characteristics. The cables may be used in wet or dry applications, installed in racks, trays or aerially. These cables have an overall jacket and can be direct buried in earth and buried in concrete. Three conductor cables are manufactured in accordance with industry accepted practice of using three symmetrically placed grounds making them advantageous for use in pulse-width modulated cables and variable frequency drive applications.

Copper Conductor XLP Insulation Filters Binder Tape CorrugatedArmor PVC Jacket

Specifications • National Fire Protection Association (NFPA 70) National Electric Code (NEC) • UL 1569 Metal Clad Cables • UL 44 Thermoset-Insulated Wires and Cables • ICEA S-95-658/NEMA WC70 Nonshielded 0-2kV Cables • IEEE 1202 - Flame Testing of Cable for use in Cable Tray in Industrial and Commercial Occupancies (70,000 BTU) • ICEA T-29-520 Vertical Cable Tray Flame Tests (210,000 BTU) • Conforms to Standard ICEA S-95-658/NEMA WC70 Nonshielded 0-2KV Cables. • Conductors conforms to Standard UL 44 Thermoset-Insulated Wires and Cables. • Listed by ULAs Type MC-HL per Standard UL 1569 Metal-Clad Cables. • Listed by ULAs Sunlight Resistant, for Direct Burial, For CT Use and IEEE 1202. Options • Custom ground sizes • CPE jacket. Notes **Based on single cable in uncovered cable tray at 30°C ambient temperature per NEC. For other installations refer to the NEC.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

908 20160220

ARMORED CABLES

Copper Ground Wire

Construction This specification covers single and multi-conductor power cables insulated with flame retardant crosslinked polyethylene (XLP). The insulated conductors cabled with a ground wire or wires, and the assembly are encased in a moisture impervious continuously welded corrugated aluminum armor, and covered with a protective jacket overall. Three conductor type cables are constructed for VFD applications. Conductors - The conductors consist of uncoated soft, copper strands meeting the requirements of ASTM B3. Unless otherwise specified the conductors are supplied as compact round per ASTM B496. Insulation - The insulation is flame-retardant crosslinked polyethylene (XHHW-2) extruded concentrically over the conductor to the wall thickness for Type XHHW-2 as specified in the relevant governing specification. Conductor Coding - Phase identification is provided by number code on each insulated conductor. Ground Wire - Three stranded bare copper ground wires located in each of the outer interstices for 3 conductor cables, one in one of the interstices for 2 or 4 conductor cables, or helically applied concentric wires for single conductor cables. The total ground wire cross section in all cases meets the minimum UL requirements for ground size. Assembly - Conductors and ground wire are cabled together with a left hand lay and suitable fillers make the cable round. A binder tape is applied. Armor - Over the taped assembly there is continuously welded corrugated aluminum armor. Jacket - A protective sunlight and ozone resistant PVC or low smoke halogen free (LSHF) polyolefin jacket is extruded for a tight fit over the interlocked armor.

Continuously Corrugated Welded Armored Power Cable FR-XLP Insulation (XHHW-2), 600V/1kV Type MC-HL 4/C Item #

Conductor No. of Strands

2 1 1/0 2/0 3/0 4/0 250 1/0 2/0 3/0 4/0 250 350 400 500 750 1000*

7 19 19 19 19 19 37 19 19 19 19 37 37 37 37 61 61

Conductor Nominal O.D. (in) 0.27 0.30 0.34 0.38 0.42 0.48 0.52 0.34 0.38 0.42 0.48 0.52 0.62 0.66 0.74 0.91 1.12

Insulation (mil)

Jacket (mil)

45 55 55 55 55 55 65 55 55 55 55 65 65 65 65 80 80

50 50 50 60 60 60 60 50 50 50 60 60 60 60 75 75 85

No. xAWG Copper Ground Wires 6 6 6 6 4 4 4 3 x 10 3 x 10 3x8 3x8 3x8 3x6 3x6 3x6 3x4 3x4

Approximate O.D. (in)

Ampacity** 90°C

1.44 1.44 1.57 1.77 1.77 1.87 2.06 1.44 1.57 1.57 1.77 1.87 2.28 2.28 2.58 3.08 3.33

104 120 136 156 180 208 232 170 195 225 260 290 350 375 430 535 615

Approximate Net Weight (lb/MFT) 1440 1705 2045 2480 3000 3620 4240 1645 1965 2375 2880 3340 4520 5070 6260 9100 11965

ARMORED CABLES

CWCAPC-4-2 CWCAPC-4-1 CWCAPC-4-1/0 CWCAPC-4-2/0 CWCAPC-4-3/0 CWCAPC-4-4/0 CWCAPC-4-250 CWCAPC-3-1/0 CWCAPC-3-2/0 CWCAPC-3-3/0 CWCAPC-3-4/0 CWCAPC-3-250 CWCAPC-3-350 CWCAPC-3-400 CWCAPC-3-500 CWCAPC-3-750 CWCAPC-3-1000*

Conductor Size (AWG/kcmil)

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 908 20160220

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Continuously Corrugated Welded Armored Power Cable FR-XLP Insulation (XHHW-2), 600V/1kV Type MC-HL 5/C Application All cables produced to this specification are recognized by the NEC as 600 Volt Type MC-HL and are suitable for use as described in the code. The conductor temperatures are rated for continuous operation of 90°C, for emergency overload of 130°C and for short circuit of 250°C. The cables meet the requirements for application in NEC Class I, Class II and Class III, Div. 1 and 2, Hazardous Locations covered under NEC articles 501, 502 and 503. The cables are intended for use in industrial applications where aluminum armor protection is necessary. The continuously welded sheath serves to provide a completely moisture impervious barrier for the core as well as providing superior electro static shielding characteristics. The cables may be used in wet or dry applications, installed in racks, trays or aerially. These cables have an overall jacket and can be direct buried in earth and buried in concrete. Three conductor cables are manufactured in accordance with industry accepted practice of using three symmetrically placed grounds making them advantageous for use in pulse-width modulated cables and variable frequency drive applications.

Copper Conductor XLP Insulation Copper Ground Wire Binder Tape CorrugatedArmor PVC Jacket

Specifications • National Fire Protection Association (NFPA 70) National Electric Code (NEC) • UL 1569 Metal Clad Cables • UL 44 Thermoset-Insulated Wires and Cables • ICEA S-95-658/NEMA WC70 Nonshielded 0-2kV Cables • IEEE 1202 - Flame Testing of Cable for use in Cable Tray in Industrial and Commercial Occupancies (70,000 BTU) • ICEA T-29-520 Vertical Cable Tray Flame Tests (210,000 BTU) • Conforms to Standard ICEA S-95-658/NEMA WC70 Nonshielded 0-2KV Cables. • Conductors conforms to Standard UL 44 Thermoset-Insulated Wires and Cables. • Listed by ULAs Type MC-HL per Standard UL 1569 Metal-Clad Cables. • Listed by ULAs Sunlight Resistant, for Direct Burial, For CT Use and IEEE 1202. Options • Custom ground sizes • CPE jacket. Notes **Based on single cable in uncovered cable tray at 30°C ambient temperature per NEC. For other installations refer to the NEC.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

909 20160220

ARMORED CABLES

Filters

Construction This specification covers single and multi-conductor power cables insulated with flame retardant crosslinked polyethylene (XLP). The insulated conductors cabled with a ground wire or wires, and the assembly are encased in a moisture impervious continuously welded corrugated aluminum armor, and covered with a protective jacket overall. Three conductor type cables are constructed for VFD applications. Conductors - The conductors consist of uncoated soft, copper strands meeting the requirements of ASTM B3. Unless otherwise specified the conductors are supplied as compact round per ASTM B496. Insulation - The insulation is flame-retardant crosslinked polyethylene (XHHW-2) extruded concentrically over the conductor to the wall thickness for Type XHHW-2 as specified in the relevant governing specification. Conductor Coding - Phase identification is provided by number code on each insulated conductor. Ground Wire - Three stranded bare copper ground wires located in each of the outer interstices for 3 conductor cables, one in one of the interstices for 2 or 4 conductor cables, or helically applied concentric wires for single conductor cables. The total ground wire cross section in all cases meets the minimum UL requirements for ground size. Assembly - Conductors and ground wire are cabled together with a left hand lay and suitable fillers make the cable round. A binder tape is applied. Armor - Over the taped assembly there is continuously welded corrugated aluminum armor. Jacket - A protective sunlight and ozone resistant PVC or low smoke halogen free (LSHF) polyolefin jacket is extruded for a tight fit over the interlocked armor.

Continuously Corrugated Welded Armored Power Cable FR-XLP Insulation (XHHW-2), 600V/1kV Type MC-HL 5/C Item #

Conductor No. of Strands

8* 6* 4* 2 1 1/0 2/0 3/0 4/0 250 300 350

7 7 7 7 19 19 19 19 19 37 37 37

Conductor Nominal O.D. (in) 0.14 0.18 0.23 0.27 0.30 0.34 0.38 0.42 0.48 0.52 0.57 0.62

Insulation (mil)

Jacket (mil)

45 45 45 45 55 55 55 55 55 65 65 65

50 50 50 50 50 60 60 60 60 60 75 75

No. xAWG Copper Ground Wires 10 8 8 6 6 6 6 4 4 4 3 3

Approximate O.D. (in)

Ampacity** 90°C

1.06 1.14 1.44 1.44 1.57 1.77 1.77 1.87 2.06 2.28 2.58 2.58

44 60 88 104 120 136 156 180 208 232 256 280

Approximate Net Weight (lb/MFT) 700 855 1235 1685 2055 2490 2960 3625 4420 5190 6245 7090

ARMORED CABLES

CWCAPC-5-8* CWCAPC-5-6* CWCAPC-5-4* CWCAPC-5-2 CWCAPC-5-1 CWCAPC-5-1/0 CWCAPC-5-2/0 CWCAPC-5-3/0 CWCAPC-5-4/0 CWCAPC-5-250 CWCAPC-5-300 CWCAPC-5-350

Conductor Size (AWG/kcmil)

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 909 20160220

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

UL Type MC Copper Conductor with Ground PVC Jacket 600V Applications MC Cable is approved for use in many applications including direct burial, use in cable tray and outdoor exposure. The PVC jacket is free of harmful heavy metals in compliance with RoHS, Directive 2002/95/EC. • Run from the combiner box to the inverter • Suitable for rooftop solar applications • Outdoors • In wet locations (Type XHHW-2 , or RHW-2 conductors) • Direct buried • Encased in concrete • Hazardous locations • Strong, but lightweight alloy armor resists damage • Suitable for wet locations, direct burial, encased in concrete and other uses per the NEC • More flexible than conduit • Factory tested engineered product that protects conductors from damage during installation • Meets or exceeds requirements of the NEC, as well as applicable UL Standards Construction Stranded soft drawn copper conductor. Flame retardant thermoset crosslinked polyethylene (XLPE) insulation Type XHHW-2 conductors rated for wet or dry locations at temperatures not to exceed 90ºC. Grounding is one bare copper stranded conductor, except for sizes 14AWG through 1AWG contain a green insulated grounding conductor. Phase and grounding conductors are cabled together with binder tape. aluminum interlocked armor, applied over the binder tape and a longitudinal marker tape, for ID, when unjacketed. Black sunlight resistant and flame retardant polyvinyl chloride (PVC) compound jacket. Special constructions available upon request.

Notes Ampacities are based on Table 310.15(B)(16) of the NEC. * Ampacities shown are for general use as specified by the NEC, Section 310.15. For equipment marked for use at higher temperatures, the conductor ampacity shall be limited to the following per NEC 110.14(C): • 60°C when terminated to equipment for circuits rated 100 amperes or less or marked for size 14AWG through 1AWG conductor. • 75°C when terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1AWG. • 90°C for ampacity derating purposes. When the neutral is considered current-carrying conductor, the ampacity of 4/C cables shall be reduced by a factor of 0.80 per NEC 310.15(B)(2)(a). The above data is approximate and subject to normal manufacturing tolerances.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

910 20160220

ARMORED CABLES

Standards • Underwriters Laboratories Standards UL-44 • Class B stranding, per ASTM B 801 • UL-1569 for Type MC • Federal Specification A-A59544 • IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test • ICEA T-29-520 (210,000 Btu/hr) Flame Test, and the National Electrical Code (NEC) • Single conductors are rated XHHW-2 600V, and CT Use 1/0AWG and larger. • Additional UL Type PV available upon request. • Aluminum armor is rated for Direct Burial, using 6AWG and larger conductors, with overall jacket

UL Type MC Copper Conductor with Ground PVC Jacket 600V

ARMORED CABLES

Item #

Conductor Size (AWG/kcmil)

No. of Conductors

Green Ground

14-02AIAWG 14-03AIAWG 14-04AIAWG 12-02AIAWG 12-03AIAWG 12-04AIAWG 10-02AIAWG 10-03AIAWG 10-04AIAWG 8-02AIAWG 8-03AIAWG 8-04AIAWG 6-02AIAWG 6-03AIAWG 6-04AIAWG 4-03AIAWG 4-04AIAWG 3-03AIAWG 3-04AIAWG 2-03AIAWG 2-04AIAWG 1-03AIAWG

14 14 14 12 12 12 10 10 10 8 8 8 6 6 6 4 4 3 3 2 2 1

2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 3 4 3 4 3 4 3

1-04AIAWG

1

4

1/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 250 250 300 300 350 350 400 400 500 500 600 600 750 750

3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4

14AWG 14AWG 14AWG 12AWG 12AWG 12AWG 10AWG 10AWG 10AWG 10AWG 10AWG 10AWG 8AWG 8AWG 8AWG 8AWG 8AWG 6AWG 6AWG 6AWG 6AWG 6AWG Green Insulated 6AWG Green Insulated 6AWG Bare 6AWG Bare 6AWG Bare 6AWG Bare 4AWG Bare 4AWG Bare 4AWG Bare 4AWG Bare 4AWG Bare 4AWG Bare 3AWG Bare 3AWG Bare 3AWG Bare 3AWG Bare 3AWG Bare 3AWG Bare 2AWG Bare 2AWG Bare 2AWG Bare 2AWG Bare 1AWG Bare 1AWG Bare

1/0-03AIAWG 1/0-04AIAWG 2/0-03AIAWG 2/0-04AIAWG 3/0-03AIAWG 3/0-04AIAWG 4/0-03AIAWG 4/0-04AIAWG 250-03AIAWG 250-04AIAWG 300-03AIAWG 300-04AIAWG 350-03AIAWG 350-04AIAWG 400-03AIAWG 400-04AIAWG 500-03AIAWG 500-04AIAWG 600-03AIAWG 600-04AIAWG 750-03AIAWG 750-04AIAWG

Outside Diameter Over Armor 0.464 0.498 0.536 0.503 0.542 0.584 0.553 0.597 0.646 0.677 0.757 0.834 0.791 0.884 0.974 0.964 1.070 1.049 1.164 1.103 1.228 1.195

Outside Diameter Over Jacket 0.564 0.700 0.737 0.705 0.747 0.786 0.754 0.799 0.848 0.892 0.957 1.021 0.974 1.045 1.123 1.161 1.250 1.220 1.329 1.306 1.415 1.295

Jacket Thickness

0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05

Approximate Net Weight (lb/MFT) 191 219 249 227 265 304 282 335 389 427 524 618 566 700 832 900 1093 1075 1306 1234 1515 1162

Allowable Ampacity 75°C (Amps) 15 15 15 20 20 20 30 30 30 50 50 50 65 65 65 85 85 100 100 115 115 130

Allowable Ampacity 90°C (Amps) 15 15 15 20 20 20 30 30 30 55 55 55 75 75 75 95 95 115 115 130 130 145

1.336

1.436

0.05

1477

130

145

1.213 1.335 1.308 1.441 1.415 1.562 1.536 1.697 1.648 1.822 1.760 1.948 1.862 2.061 1.956 2.167 2.131 2.363 2.411 2.677 2.631 2.923

1.313 1.435 1.408 1.541 1.515 1.682 1.656 1.817 1.768 1.942 1.880 2.068 1.982 2.181 2.076 2.287 2.251 2.513 2.561 2.827 2.781 3.073

0.05 0.05 0.05 0.05 0.05 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.075 0.075 0.075 0.075 0.075

1359 1742 1624 2092 2048 2637 2498 3233 2904 3770 3192 4211 3931 5120 4173 5514 5451 7124 6454 8450 8015 10506

150 150 175 175 200 200 230 230 255 255 285 285 310 310 335 335 380 380 420 420 475 475

170 170 195 195 225 225 260 260 290 290 320 320 350 350 380 380 430 430 475 475 535 535

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 910 20160220

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

CONTROL CABLES Table of Contents Control Cable FR-XLPE Insulated Conductors, PVC Jacket 600V.......................................501 Power Cable FR-XLPE Insulated Conductors, PVC Jacket 600V .......................................502 Control Cable FR-XLPE Insulated Conductors, CPE Jacket 600V ..................................... 503 Power Cable FR-XLPE Insulated Conductors, CPE Jacket 600V.........................................504 Control Cable FR-XLPE Insulated Conductors, Copper Shield, CPE Jacket 600V ............505 Control Cable FR-XLPE Insulated Conductors, XLPO Jacket 600V....................................506 Power Cable FR-XLPE Insulated Conductors, XLPO Jacket 600V......................................507 Control Cable FR-XLPE Insulated Conductors, Smooth Helical Bare Copper Shield, XLPO Jacket 600V..................................................................................................................508 Control Cable FR-XLPE Insulated Conductors, Longitudinal Corrugated Bare Copper Shield, XLPO Jacket 600V .....................................................................................................531 Control Cable FR-EPR Insulated Conductors, PVC Jacket 600V ........................................509 Power Cable FR-EPR Insulated Conductors, PVC Jacket 600V ........................................510 Control Cable FR-EPR Insulated Conductors, CPE Jacket 600V .........................................511 Power Cable FR-EPR Insulated Conductors, CPE Jacket 600V...........................................512 Control Cable FR-EPR Insulated Conductors, Copper Shield, CPE Jacket 600V...............513 20/10 Control Cable, PE/PVC Insulated Conductors, PVC Jacket 600V ..............................514 20/10 Control Cable, PE/PVC Insulated Conductors, Shield, PVC Jacket 600V .................515 THHN/PVC Tray Cable (Type TC) 600V TFN, THWN or THHN Insulated Conductors, PVC Jacket 600V .......................................517 TFN, THWN or THHN Insulated Conductors, Shielded, Drain Wire, PVC Jacket 600V ..518 THWN or THHN Insulated Conductors with Ground, PVC Jacket 600V .........................519 Aluminum Three Conductor UL Type TC 600V .....................................................................529 Aluminum Four Conductor UL Type TC 600V ......................................................................530 Thermocouple Cable, EX, JX, KX, TX 600V .........................................................................520 IMSA 20-1 & ISMA 19-1 Traffic Control Cable 600V ............................................................521 IMSA 50-2 Tube Loop Lead-In Wire 600V .............................................................................522

IMSA 51-5 Inductant Loop Detector Cable 600V .................................................................525 IMSA Selection Guide ...........................................................................................................526 IMSA Color Code Chart .........................................................................................................527 IMSA Cable Shipping Weights — XHHX-2 & USE-2 ...........................................................528 Wire & Cable: Methods of Color Coding & Color Coding Charts ..........................................B

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

500 20150508

CONTROL CABLES

IMSA 51-1 THHN Loop Detector Lead-In Wire 600V ............................................................523 IMSA 51-3 Loop Detector Wire 600V ....................................................................................524

CONTROL CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Control Cable FR-XLPE Insulated Conductors PVC Jacket, 600V Applications As flame-retardant multi-conductor control, signal or power cables rated 600V, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Construction Stranded uncoated copper conductors, 30 mils FR-XLPE flame-retardant cross-linked polyethylene insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, cable tape, PVC jacket overall, surface printed. Standards • Listed by UL as Type TC per Standard 1277 for Tray Cables. • Cables UL listed for Direct Burial. • Individual conductors pass UL VW-1 flame test. • Individual conductors UL listed as Type XHHW-2. • Overall jacket UL listed as Sunlight Resistant. • Cables with grounding conductor UL listed for Open Wiring. • Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test. • Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test. • Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables. Notes • Cables may be supplied with an insulated ground and marked “Open Wiring.” • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request. Options • Bare or Tinned Copper • Flexible stranded conductors • Color Coding: ICEA Method 1, Table E-1 • EPR Insulation • CPE, CSPE, LSOH Jackets • Insulated ground wires or bare ground wires • Overall copper tape shield • Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications. CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

501 20140110

Control Cable FR-XLPE Insulated Conductors PVC Jacket, 600V

CONTROL CABLES

Item #

Number Size of AWG Conductors

Number of Nominal Nominal Nominal Nominal Nominal Strands Insulation Insulation Jacket Jacket Cable Thickness Thickness Thickness Thickness O.D. (in) (mm) (in) (mm) (in)

Nominal Cable O.D. (mm)

Copper Weight /MFT (lb)

Copper Weight /km (kg)

Approx. Weight /MFT (lb)

Approx. Weight /km (kg))

14-R-PVC-2-FLAT 2 FLAT 14-R-PVC-2 2 14-R-PVC-3 3 14-R-PVC-4 4 14-R-PVC-5 5 14-R-PVC-7 7 14-R-PVC-9 9 14-R-PVC-12 12 14-R-PVC-19 19 14-R-PVC-25 25 14-R-PVC-30 30 14-R-PVC-37 37

14 14 14 14 14 14 14 14 14 14 14 14

7 7 7 7 7 7 7 7 7 7 7 7

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.080 0.080 0.080

1.14 1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 2.03

.235x.370 0.365 0.390 0.425 0.465 0.590 0.620 0.680 0.800 0.985 1.050 1.130

5.97x9.40 9.270 9.910 10.800 11.810 14.990 15.750 17.270 20.320 25.020 26.670 28.700

25 25 40 53 66 93 119 159 252 323 387 490

37 37 59 79 99 138 177 237 375 481 571 729

62 73 93 116 140 176 245 302 460 641 740 888

92 109 138 173 208 262 365 449 685 954 1101 1322

12-R-PVC-2-FLAT 2 Flat 12-R-PVC-2 2 12-R-PVC-3+GRND 3+Grnd 12-R-PVC-3 3 12-R-PVC-4 4 12-R-PVC-5 5 12-R-PVC-7 7 12-R-PVC-9 9 12-R-PVC-12 12 12-R-PVC-19 19 12-R-PVC-25 25 12-R-PVC-30 30 12-R-PVC-37 37

12 12 12 12 12 12 12 12 12 12 12 12 12

7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.080 0.080 0.080 0.080

1.14 1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 2.03 2.03

.245x.400 0.410 0.435 0.435 0.475 0.515 0.595 0.695 0.780 0.930 1.095 1.150 1.240

6.2 x10.16 10.410 11.050 11.050 12.070 13.080 15.110 17.650 19.810 23.620 27.810 29.210 31.500

40 41 86 65 86 108 150 193 258 403 515 618 741

60 61 128 96 128 160 224 288 385 600 767 920 1103

86 96 143 125 157 191 260 340 429 681 885 1005 1185

128 143 213 186 234 284 387 506 638 1013 1317 1496 1764

10-R-PVC-2-FLAT 10-R-PVC-2 10-R-PVC-3+GRND 10-R-PVC-3 10-R-PVC-4 10-R-PVC-5 10-R-PVC-7 10-R-PVC-9 10-R-PVC-12

10 10 10 10 10 10 10 10 10

7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.06 0.06 0.06 0.06 0.08

1.14 1.14 1.14 1.14 1.52 1.52 1.52 1.52 2.03

.290x.480 7.37x12.19 0.455 11.56 0.485 12.32 0.485 12.32 0.515 13.08 0.615 15.62 0.67 17.02 0.785 19.94 0.895 22.73

66 67 135 101 135 167 234 295 402

98 100 200 150 200 249 349 440 598

114 130 201 173 236 287 371 479 644

170 193 299 257 351 427 552 713 958

2 Flat 2 3+Grnd 3 4 5 7 9 12

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 501 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Power Cable FR-XLPE Insulated Conductors PVC Jacket, 600V Applications As flame-retardant three or four conductor power cables rated 600V, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC cable is also approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, or direct buried. Construction Class B stranded uncoated copper conductor, XLPE cross-linked polyethylene insulation, surface print phase identification. Three or four insulated conductors twisted with a Class B stranded uncoated copper grounding conductor in two opposite valleys, suitable fillers, cable tape, PVC jacket overall, surface printed. Standards • Listed by UL as Type TC per Standard 1277 for Tray Cables. • Individual conductors UL listed as Type XHHW-2. • Overall jacket UL listed as Sunlight Resistant. • Cables pass UL and IEEE-383 ribbon burner flame tests. • Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test (2 AWG and larger). • Cables UL listed for Direct Burial. • Cables UL listed for Open Wiring. • Cables meet requirements of ICEA S-95-658/NEMA WC70. • Color Code ICEA Method 4 Notes • Ampacity in accordance with the National Electrical Code for cables in uncovered cable tray without maintained spacing and for cables in raceway or directly buried; at the conductor temperature indicated, in wet or dry locations, 30°C ambient temperature. • Grounding conductor per UL Standard 1277 for Type TC Tray Cable Options • Bare or Tinned Copper • Flexible stranded conductors • E1 or E2 color codes • EPR Insulation • CPE, CSPE, LSOH Jackets • Insulated ground wires or bare ground wires • Overall copper tape shield • Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications.. CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

502 20140110

Power Cable FR-XLPE Insulated Conductors PVC Jacket, 600V

CONTROL CABLES

Item #

Number of Size Conductors AWG

Conductor Ground Nominal Nominal Nominal Nominal Strand Wire Insulation Insulation Jacket Jacket Size Thickness Thickness Thickness Thickness AWG (in) (mm) (in) (mm) 7/.0242 14 0.0300 0.76 0.05 1.14 7/.0305 12 0.0300 0.76 0.05 1.14 7/.0385 10 0.0300 0.76 0.06 1.52

Nominal Nominal Cable Cable O.D. O.D. (in) (mm) 0.425 10.80 0.475 12.07 0.515 13.08

Copper Weight /MFT (lb) 53 86 135

Copper Weight /km (kg) 79 128 200

Approx. Weight /MFT (lb) 116 157 236

Approx. Weight /km (kg) 173 234 351

3RXLP-14 3RXLP-12 3RXLP-10

3 3 3

14 12 10

3RXLP-8 4RXLP-8

3 4

8 8

7/.0486 7/.0486

10 10

0.045 0.045

1.14 1.14

0.06 0.06

1.52 1.52

0.640 0.705

16.26 17.91

190 242

283 360

314 385

467 573

3RXLP-6 4RXLP-6

3 4

6 6

7/.0612 7/.0612

8 8

0.045 0.045

1.14 1.14

0.06 0.06

1.52 1.52

0.720 0.790

18.29 20.07

301 384

448 571

445 558

662 830

3RXLP-4 4RXLP-4

3 4

4 4

7/.0772 7/.0772

8 8

0.045 0.045

1.14 1.14

0.08 0.08

2.03 2.03

0.875 0.950

22.23 24.13

448 578

667 862

653 820

972 1220

3RXLP-2 4RXLP-2

3 4

2 2

7/.0974 7/.0974

6 6

0.045 0.045

1.14 1.14

0.08 0.08

2.03 2.03

1.000 1.095

25.40 27.81

716 919

1066 1368

964 1214

1435 1807

3RXLP-1 4RXLP-1

3 4

1 1

19/.0664 19/.0664

6 6

0.055 0.055

1.40 1.40

0.08 0.08

2.03 2.03

1.120 1.235

28.45 31.37

872 1136

1298 1691

1199 1704

1784 2536

3RXLP-1/0 4RXLP-1/0

3 4

1/0 1/0

19/.0745 19/.0745

6 6

0.055 0.055

1.40 1.40

0.08 0.08

2.03 2.03

1.215 1.340

30.86 34.04

1081 1413

1609 2103

1414 1825

2104 2716

3RXLP-2/0 4RXLP-2/0

3 4

2/0 2/0

19/.0837 19/.0837

6 6

0.055 0.055

1.40 1.40

0.08 0.08

2.03 2.03

1.310 1.450

33.27 36.83

1341 1760

1996 2619

1706 2223

2539 3308

3RXLP-3/0 4RXLP-3/0

3 4

3/0 3/0

19/.0940 19/.0940

4 4

0.055 0.055

1.40 1.40

0.08 0.08

2.03 2.03

1.420 1.570

36.07 39.88

1717 2245

2555 3341

2437 3123

3627 4648

3RXLP-4/0 4RXLP-4/0

3 4

4/0 4/0

19/.1055 19/.1055

4 4

0.055 0.055

1.40 1.40

0.08 0.11

2.03 2.79

1.540 1.765

39.12 44.83

2132 2796

3173 4161

2600 3444

3869 5125

3RXLP-250 4RXLP-250

3 4

250 250

37/.0822 37/.0822

4 4

0.065 0.065

1.65 1.65

0.11 0.11

2.79 2.79

1.750 1.930

44.45 49.02

2494 3282

3712 4884

3142 4048

4676 6024

3RXLP-350 4RXLP-350

3 4

350 350

37/.0973 37/.0973

3 3

0.065 0.065

1.65 1.65

0.11 0.11

2.79 2.79

1.970 2.180

50.04 55.37

3474 4577

5170 6811

4230 5470

6295 8140

3RXLP-500 4RXLP-500

3 4

500 500

37/.1162 37/.1162

2 2

0.065 0.065

1.65 1.65

0.11 0.11

2.79 2.79

2.250 2.475

57.15 62.87

4938 6509

7349 9687

5829 7579

8675 11279

3RXLP-750 4RXLP-750

3 4

750 750

61/.1109 61/.1109

1 1

0.080 0.080

2.03 2.03

0.14 0.14

3.56 3.56

2.810 3.115

71.37 79.12

7278 9712

10831 14453

9101 11746

13544 17480

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 502 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Control Cable FR-XLPE Insulated Conductors CPE Jacket, 600V Applications As flame-retardant multi-conductor control, signal or power cables rated 600V, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Construction Stranded uncoated copper conductors, 30 mils FR-XLPE flame-retardant cross-linked polyethylene insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, cable tape, CPE jacket overall, surface printed. Standards • Listed by UL as Type TC per Standard 1277 for Tray Cables. • Cables UL listed for Direct Burial. • Individual conductors pass UL VW-1 flame test. • Individual conductors UL listed as Type XHHW-2. • Overall jacket UL listed as Sunlight Resistant. • Cables with grounding conductor UL listed for Open Wiring. • Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test. • Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test. • Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables. • Color Code ICEA Method 4. Notes • Cables may be supplied with an insulated ground and marked “Open Wiring.” • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request. Options • Bare or Tinned Copper • Flexible stranded conductors • Color Coding: ICEA Method 1, Table E-1 • EPR Insulation • PVC, CSPE, LSOH Jackets • Insulated ground wires or bare ground wires • Overall copper tape shield • Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction CONTROL CABLES

Consult AWG for a variety of alternate constructions for specific applications.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

503 20140110

Control Cable FR-XLPE Insulated Conductors CPE Jacket, 600V

CONTROL CABLES

Item #

Number of Conductors

Size AWG

Number of Nominal Nominal Nominal Nominal Nominal Strands Insulation Insulation Jacket Jacket Cable Thickness Thickness Thickness Thickness O.D. (in) (mm) (in) (mm) (in)

Nominal Cable O.D. (mm)

Copper Weight /MFT (lb)

Copper Weight /km (kg)

Approx. Weight /MFT (lb)

Approx. Weight /km (kg)

14-R-CPE-2-FLAT 2 FLAT 14-R-CPE-2 2 14-R-CPE-3 3 14-R-CPE-4 4 14-R-CPE-5 5 14-R-CPE-7 7 14-R-CPE-9 9 14-R-CPE-12 12 14-R-CPE-19 19 14-R-CPE-25 25 14-R-CPE-30 30 14-R-CPE-37 37

14 14 14 14 14 14 14 14 14 14 14 14

7 7 7 7 7 7 7 7 7 7 7 7

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.080 0.080 0.080

1.14 1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 2.03

.235x.370 0.365 0.390 0.425 0.465 0.590 0.620 0.680 0.800 0.985 1.050 1.130

5.97x9.40 9.270 9.910 10.800 11.810 14.990 15.750 17.270 20.320 25.020 26.670 28.700

25 25 40 53 66 93 119 159 252 323 387 490

37 37 59 79 99 138 177 237 375 481 571 729

62 73 93 116 140 176 245 302 460 641 740 888

92 109 138 173 208 262 365 449 685 954 1101 1322

12-R-CPE-2-FLAT 2 FLAT 12-R-CPE-2 2 12-R-CPE-3+GRND 3+Grnd 12-R-CPE-3 3 12-R-CPE-4 4 12-R-CPE-5 5 12-R-CPE-7 7 12-R-CPE-9 9 12-R-CPE-12 12 12-R-CPE-19 19 12-R-CPE-25 25 12-R-CPE-30 30 12-R-CPE-37 37

12 12 12 12 12 12 12 12 12 12 12 12 12

7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.080 0.080 0.080 0.080

1.14 1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 2.03 2.03

.245x.400 6.22x10.16 0.410 10.410 0.435 11.050 0.435 11.050 0.475 12.070 0.515 13.080 0.595 15.110 0.695 17.650 0.780 19.810 0.930 23.620 1.095 27.810 1.150 29.210 1.240 31.500

40 41 86 65 86 108 150 193 258 403 515 618 741

60 61 128 96 128 160 224 288 385 600 767 920 1103

86 96 143 125 157 191 260 340 429 681 885 1005 1185

128 143 213 186 234 284 387 506 638 1013 1317 1496 1764

10-R-CPE-2-FLAT 2 FLAT 10-R-CPE-2 2 10-R-CPE-3+GRND 3+Grnd 10-R-CPE-3 3 10-R-CPE-4 4 10-R-CPE-5 5 10-R-CPE-7 7 10-R-CPE-9 9 10-R-CPE-12 12

10 10 10 10 10 10 10 10 10

7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.080

1.14 1.14 1.14 1.14 1.52 1.52 1.52 1.52 2.03

.290x.480 0.455 0.485 0.485 0.515 0.615 0.670 0.785 0.895

66 67 135 101 135 167 234 295 402

98 100 200 150 200 249 349 440 598

114 130 201 173 236 287 371 479 644

170 193 299 257 351 427 552 713 958

7.37x12.19 11.560 12.320 12.320 13.080 15.620 17.020 19.940 22.730

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 503 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Power Cable FR-XLPE Insulated Conductors CPE Jacket, 600V Applications As flame-retardant three or four conductor power cables rated 600V, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC cable is also approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, or direct buried. Construction Class B stranded uncoated copper conductor, FR-XLPE flame-retardant cross-linked polyethylene insulation, surface print phase identification. Three or four insulated conductors twisted with a Class B stranded uncoated copper grounding conductor and suitable fillers, cable tape, CPE jacket overall, surface printed. Standards • Listed by UL as Type TC per Standard 1277 for Tray Cables. • Individual conductors UL listed as Type XHHW-2. • Individual conductors pass UL VW-1 flame test. • Overall jacket UL listed as Sunlight Resistant and Oil Resistant II. • Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test. • Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test. • Cables UL listed for Direct Burial. • Cables UL listed for Open Wiring. • Cables meet requirements of ICEA S-95-658/NEMA WC70. • Color Code ICEA Method 4. Notes • Ampacity in accordance with the National Electrical Code for cables in uncovered cable tray without maintained spacing and for cables in raceway or directly buried; at the conductor temperature indicated, in wet or dry locations, 30°C ambient temperature. • Grounding conductor per UL Standard 1277 for Type TC Tray Cable. Options • Bare or Tinned Copper • Flexible stranded conductors • E1 or E2 color codes • EPR Insulation • PVC, CSPE, LSOH Jackets • Insulated ground wires or bare ground wires • Overall copper tape shield, Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications. CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

504 20140110

Power Cable FR-XLPE Insulated Conductors CPE Jacket, 600V

CONTROL CABLES

Item #

Number of Size Conductors AWG

Conductor Ground Nominal Nominal Nominal Nominal Strand Wire Insulation Insulation Jacket Jacket Size Thickness Thickness Thickness Thickness AWG (in) (mm) (in) (mm) 7/.0242 14 0.0300 0.76 0.05 1.14 7/.0305 12 0.0300 0.76 0.05 1.14 7/.0385 10 0.0300 0.76 0.06 1.52

Nominal Nominal Cable Cable O.D. O.D. (in) (mm) 0.425 10.80 0.475 12.07 0.515 13.08

Copper Weight /MFT (lb) 53 86 135

Copper Weight /km (kg) 79 128 200

Approx. Weight /MFT (lb) 116 157 236

Approx. Weight /km (kg) 173 234 351

3EXLP-14 3EXLP-12 3EXLP-10

3 3 3

14 12 10

3EXLP-8 4EXLP-8

3 4

8 8

7/.0486 7/.0486

10 10

0.045 0.045

1.14 1.14

0.06 0.06

1.52 1.52

0.640 0.705

16.26 17.91

190 242

283 360

314 385

467 573

3EXLP-6 4EXLP-6

3 4

6 6

7/.0612 7/.0612

8 8

0.045 0.045

1.14 1.14

0.06 0.06

1.52 1.52

0.720 0.790

18.29 20.07

301 384

448 571

445 558

662 830

3EXLP-4 4EXLP-4

3 4

4 4

7/.0772 7/.0772

8 8

0.045 0.045

1.14 1.14

0.08 0.08

2.03 2.03

0.875 0.950

22.23 24.13

448 578

667 862

653 820

972 1220

3EXLP-2 4EXLP-2

3 4

2 2

7/.0974 7/.0974

6 6

0.045 0.045

1.14 1.14

0.08 0.08

2.03 2.03

1.000 1.095

25.40 27.81

716 919

1066 1368

964 1214

1435 1807

3EXLP-1 4EXLP-1

3 4

1 1

19/.0664 19/.0664

6 6

0.055 0.055

1.40 1.40

0.08 0.08

2.03 2.03

1.120 1.235

28.45 31.37

872 1136

1298 1691

1199 1704

1784 2536

3EXLP-1/0 4EXLP-1/0

3 4

1/0 1/0

19/.0745 19/.0745

6 6

0.055 0.055

1.40 1.40

0.08 0.08

2.03 2.03

1.215 1.340

30.86 34.04

1081 1413

1609 2103

1414 1825

2104 2716

3EXLP-2/0 4EXLP-2/0

3 4

2/0 2/0

19/.0837 19/.0837

6 6

0.055 0.055

1.40 1.40

0.08 0.08

2.03 2.03

1.310 1.450

33.27 36.83

1341 1760

1996 2619

1706 2223

2539 3308

3EXLP-3/0 4EXLP-3/0

3 4

3/0 3/0

19/.0940 19/.0940

4 4

0.055 0.055

1.40 1.40

0.08 0.08

2.03 2.03

1.420 1.570

36.07 39.88

1717 2245

2555 3341

2437 3123

3627 4648

3EXLP-4/0 4EXLP-4/0

3 4

4/0 4/0

19/.1055 19/.1055

4 4

0.055 0.055

1.40 1.40

0.08 0.11

2.03 2.79

1.540 1.765

39.12 44.83

2132 2796

3173 4161

2600 3444

3869 5125

3EXLP-250 4EXLP-250

3 4

250 250

37/.0822 37/.0822

4 4

0.065 0.065

1.65 1.65

0.11 0.11

2.79 2.79

1.750 1.930

44.45 49.02

2494 3282

3712 4884

3142 4048

4676 6024

3EXLP-350 4EXLP-350

3 4

350 350

37/.0973 37/.0973

3 3

0.065 0.065

1.65 1.65

0.11 0.11

2.79 2.79

1.970 2.180

50.04 55.37

3474 4577

5170 6811

4230 5470

6295 8140

3EXLP-500 4EXLP-500

3 4

500 500

37/.1162 37/.1162

2 2

0.065 0.065

1.65 1.65

0.11 0.11

2.79 2.79

2.250 2.475

57.15 62.87

4938 6509

7349 9687

5829 7579

8675 11279

3EXLP-750 4EXLP-750

3 4

750 750

61/.1109 61/.1109

1 1

0.080 0.080

2.03 2.03

0.14 0.14

3.56 3.56

2.810 3.115

71.37 79.12

7278 9712

10831 14453

9101 11746

13544 17480

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 504 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Control Cable FR-XLPE Insulated Conductors Copper Shield, CPE Jacket, 600V Applications Control or signal cable for important circuits in industrial plants and station control cable for electric utilities where flame resistance is essential. Suitable for the operation and interconnection of protective devices; rated circuit voltage 600V; recommended for operation at 90°C maximum continuous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Utility grade meets or exceeds all UL requirements. Construction Stranded coated copper conductors. The insulation shall be either fire retardant ethylene propylene rubber (FR-EPR) or fire retardant cross-linked Polyethylene (FR-XLPE). ICEA Appendix E Method 1 color-coded, conductors twisted with suitable fillers, helically applied copper tape shield, CPE jacket overall, surface printed. Standards • TC Type Tray Cable per Article 340 of the NEC. • Individual conductors pass UL Standard 44 and the VW-1 vertical flame test. • Individual conductors approved as Type XHHW. •. Cables Pass IEEE-383 ribbon burner flame test. • Overall jacket approved as Sunlight Resistant. • Cables meet requirements of ICEA S-73-532, NEMA WC57 for control cables. Notes • Cables may be supplied with an insulated ground and marked “Open Wiring.” • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request. Options • Bare or Tinned Copper • Flexible stranded conductors • Color Coding: ICEA Method 1, Table E-1 • EPR Insulation • PVC, CSPE, LSOH Jackets • Insulated ground wires or bare ground wires • Overall copper tape shield • Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications. CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

505 20140110

Control Cable FR-XLPE Insulated Conductors Copper Shield, CPE Jacket, 600V

CONTROL CABLES

Item #

Number of Conductors

Conductor Stranding

Conductor Size AWG

Overall mils

Overall Diameter (in)

Approx. Cable Weight /MFT (lb)

14-402SH 14-403SH 14-404SH 14-405SH 14-406SH 14-407SH 14-408SH 14-409SH 14-412SH 14-414SH 14-415SH 14-416SH 14-418SH 14-419SH 14-420SH 14-425SH 14-427SH 14-429SH 14-431SH 14-432SH 14-437SH

2 3 4 5 6 7 8 9 12 14 15 16 18 19 20 25 27 29 31 32 37

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14

45 45 45 45 60 60 60 60 60 80 80 80 80 80 80 80 80 80 80 80 80

0.40 0.42 0.45 0.49 0.53 0.60 0.70 N/A 0.89 0.96 1.04 1.05 1.07 1.09 1.10 1.22 1.25 1.26 1.31 1.34 1.39

120 145 180 230 275 275 305 N/A 435 530 565 575 665 665 720 905 905 960 1090 1090 1165

12-452SH 12-453SH 12-454SH 12-455SH 12-456SH 12-457SH 12-458SH 12-462SH 12-464SH 12-465SH 12-466SH 12-468SH 12-469SH 12-470SH 12-475SH 12-477SH 12-479SH 12-481SH 12-482SH 12-487SH

2 3 4 5 6 7 8 12 14 15 16 18 19 20 25 27 29 31 32 37

12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

45 45 60 60 60 60 60 80 80 80 80 80 80 80 80 80 80 80 80 80

0.49 0.54 0.62 0.67 0.70 0.73 0.86 0.95 1.04 1.20 1.22 1.25 1.25 1.31 1.39 1.41 1.42 1.44 1.47 1.53

155 185 245 295 340 340 395 610 690 770 780 865 865 940 1175 1200 1270 1425 1425 1545

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 505 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Control Cable FR-XLPE Insulated Conductors Copper Shield, CPE Jacket, 600V Item #

Number of Conductors

Conductor Stranding

Conductor Size AWG

Overall mils

Overall Diameter (in)

Approx. Cable Weight /MFT (lb)

10-502SH

2

10

7

45

0.52

190

10-503SH 10-504SH 10-505SH 10-506SH 10-507SH 10-508SH 10-512SH 10-514SH 10-515SH 10-516SH 10-518SH 10-519SH 10-520SH 10-525SH 10-527SH 10-529SH 10-531SH 10-532SH 10-537SH

3 4 5 6 7 8 12 14 15 16 18 19 20 25 27 29 31 32 37

10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

60 60 60 60 60 80 80 80 80 80 80 80 80 80 80 80 80 80 80

0.62 0.68 0.73 0.80 0.85 1.05 1.10 1.14 1.20 1.24 1.27 1.27 1.34 1.48 1.52 1.54 1.60 1.63 1.70

255 320 370 440 450 755 810 920 995 1020 1140 1155 1255 1600 1625 1730 1950 1950 2120

*Part numbers are for CPE jacketed cables only

CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

505 20140110

CONTROL CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Control Cable FR-XLPE Insulated Conductors XLPO Jacket, 600V Applications As flame-retardant multi-conductor control, signal or power cables rated 600V, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Construction Stranded uncoated copper conductors, FR-XLPE flame-retardant cross-linked polyethylene insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, cable tape, XLPO jacket overall, surface printed. Standards • Listed by UL as Type TC per Standard 1277 for Tray Cables. • Cables UL listed for Direct Burial. • Individual conductors pass UL VW-1 flame test. • Individual conductors UL listed as Type XHHW-2. • Overall jacket UL listed as Sunlight Resistant. • Cables with grounding conductor UL listed for Open Wiring. • Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test. • Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test. • Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables. Notes • Cables may be supplied with an insulated ground and marked “Open Wiring.” • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request. Options • Bare or Tinned Copper • Flexible stranded conductors • Color Coding: ICEA Method 1, Table E-1 • EPR Insulation • PVC,CPE CSPE Jackets • Insulated ground wires or bare ground wires • Overall copper tape shield • Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications. CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

506 20140110

Control Cable FR-XLPE Insulated Conductors XLPO Jacket, 600V

CONTROL CABLES

Item #

Number of Conductors

Conductor Size AWG

Conductor Stranding

Insulation Thickness (in) .030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .030

Nominal Jacket Thickness (in) .045 .045 .045 .045 .045 .060 .060 .060 .060 .080 .080 .080

Nominal Jacket Thickness (mm) 1.1 1.1 1.1 1.1 1.1 1.5 1.5 1.5 1.5 2.0 2.0 2.0

14-R-XLPO-2 14-R-XLPO-3 14-R-XLPO-4 14-R-XLPO-5 14-R-XLPO-7 14-R-XLPO-9 14-R-XLPO-12 14-R-XLPO-16 14-R-XLPO-19 14-R-XLPO-26 14-R-XLPO-30 14-R-XLPO-37

2 3 4 5 7 9 12 16 19 26 30 37

14 14 14 14 14 14 14 14 14 14 14 14

7 7 7 7 7 7 7 7 7 7 7 7

12-R-XLPO-2 12-R-XLPO-3 12-R-XLPO-4 12-R-XLPO-5 12-R-XLPO-7 12-R-XLPO-9 12-R-XLPO-12 12-R-XLPO-16 12-R-XLPO-19 12-R-XLPO-26 12-R-XLPO-30 12-R-XLPO-37

2 3 4 5 7 9 12 16 19 26 30 37

12 12 12 12 12 12 12 12 12 12 12 12

10-R-XLPO-2 10-R-XLPO-3 10-R-XLPO-4 10-R-XLPO-5 10-R-XLPO-7 10-R-XLPO-9 10-R-XLPO-12

2 3 4 5 7 9 12

10 10 10 10 10 10 10

Nominal Nominal Approximate Approximate Cable Cable Cable Weight Cable Weight O.D. O.D. /MFT /Km (in) (mm) (lb) (kg) .235 x .375 5.97 x 9.53 67 99 0.400 10.2 102 151 0.435 11.0 126 186 0.475 12.1 150 222 0.520 13.2 191 283 0.650 16.5 274 406 0.710 18.0 340 503 0.790 20.1 433 641 0.835 21.2 496 734 1.040 26.4 685 1014 1.075 27.3 762 1128 1.155 29.3 915 1406

7 7 7 7 7 7 7 7 7 7 7 7

.030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .030

.045 .045 .045 .045 .060 .060 .060 .080 .080 .080 .080 .080

1.1 1.1 1.1 1.1 1.5 1.5 1.5 2.0 2.0 2.0 2.0 2.0

.255 x .415 6.48 x 11.4 0.440 11.2 0.485 12.3 0.530 13.5 0.610 15.5 0.715 18.2 0.795 20.2 0.930 23.6 0.975 24.8 1.160 29.5 1.200 30.5 1.300 33.0

92 131 164 202 283 357 462 620 710 950 1065 1285

136 194 243 299 419 528 684 918 1051 1406 1576 1902

7 7 7 7 7 7 7

.030 .030 .030 .030 .030 .030 .030

.045 .045 .060 .060 .060 .060 .080

1.1 1.1 1.5 1.5 1.5 1.5 2.0

.280 x .465 0.500 0.575 0.630 0.690 0.805 0.935

121 185 257 308 397 496 661

179 274 380 456 588 734 978

7.11 x 11.8 12.7 14.6 16.0 17.5 20.4 23.7

Part numbers are for XLPE/XLPO jacketed cables only.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 506 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Power Cable FR-XLPE Insulated Conductors XLPO Jacket, 600V Applications Flame retardant control/power cable in free air, raceway and direct burial, for use in wet or dry locations. Rated at 90°C wet or dry. Permitted for Exposed Run use in accordance with NEC for 3 or more conductors . Approved for direct burial, Class I, Div. 2 industrial hazardous locations per NEC. Sunlight-and weather-resistant. Meets cold bend test at -40°C. Construction 8 AWG thru 750 kcmil annealed stranded copper conductors per ASTM B33. Class B uncoated copper grounding conductor per ASTM B8. Flame-retardant FR-XLPE insulation, XLPO jacket, colorcoded per ICEA Method 1; Table E-1. Sizes 8 AWG and larger are color-coded per ICEA Method 4; Individual conductors colored black with conductor number surface printed in contrasting ink Standards • Listed by UL as Type TC per Standard 1277 for Tray Cables. • Cables UL listed for Direct Burial. • Individual conductors pass UL 1581 VW-1 flame test. • Individual conductors UL44 listed as Type XHHW-2. • Overall jacket UL listed as Sunlight Resistant. • Cables with grounding conductor UL listed for Open Wiring. • Cables pass IEEE-383 ribbon burner flame test. • Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test. • Cables meet requirements of ICEA S-95-658, NEMA WC70. • Cables meet requirements of ICEA T-29-520 AND CSA FT-4 • Color Code ICEA Method 4 Options • Bare or Tinned Copper • Flexible stranded conductors • E1 or E2 color codes • FRXLP or EPR Insulations • PVC, CPE, CSPE, Jackets • Insulated ground wires or bare ground wires • Overall copper tape shield • Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications.

CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

507 20140110

Power Cable FR-XLPE Insulated Conductors XLPO Jacket, 600V

CONTROL CABLES

Item #

Number of Conductors

Conductor Size AWG

Conductor Stranding

Insulation Thickness (in)

7 7 7 7

Ground Wire Size AWG 10 -

.045 .045 .045 .045

Nominal Jacket Thickness (in) .060 .060 .060 .060

Nominal Jacket Thickness (mm) 1.5 1.5 1.5 1.5

Nominal Cable O.D. (in) 0.625 0.665 0.665 0.730

Nominal Cable O.D. (mm) 15.9 16.9 16.9 18.5

Approx. Cable Wt. /MFT (lb) 199 296 321 383

Approx. Cable Wt. /Km (kg) 295 438 475 567

08-XLPO-2 08-XLPO-3 08-XLPO-3G 08-XLPO-4

2 3 3+GRD 4

8 8 8 8

06-XLPO-2 06-XLPO-3 06-XLPO-3G 06-XLPO-4

2 3 3+GRD 4

6 6 6 6

7 7 7 7

8 -

.045 .045 .045 .045

.060 .060 .060 .060

1.5 1.5 1.5 1.5

0.705 0.750 0.750 0.825

17.9 19.1 19.1 21.0

306 413 459 528

453 611 679 781

04-XLPO-2 04-XLPO-3 04-XLPO-3G 04-XLPO-4

2 3 3+GRD 4

4 4 4 4

7 7 7 7

8 -

.045 .045 .045 .045

.060 .060 .060 .080

1.5 1.5 1.5 2.0

0.805 0.860 0.860 0.990

20.4 21.8 21.8 25.1

437 597 643 803

647 884 952 1188

02-XLPO-2 02-XLPO-3 02-XLPO-3G 02-XLPO-4

2 3 3+GRD 4

2 2 2 2

7 7 7 7

6 -

.045 .045 .045 .045

.080 .080 .080 .080

2.0 2.0 2.0 2.0

0.975 1.035 1.035 1.140

24.8 26.3 26.3 29.0

672 915 991 1175

1001 1352 1467 1739

10-XLPO-3 10-XLPO-3G 10-XLPO-4

3 3+GRD 4

1/0 1/0 1/0

19 19 19

6 -

.055 .055 .055

.080 .080 .080

2.0 2.0 2.0

1.240 1.240 1.370

31.5 31.5 34.5

1399 1471 1794

2084 2192 2673

20-XLPO-3 20-XLPO-3G 20-XLPO-4

3 3+GRD 4

2/0 2/0 2/0

19 19 19

6 -

.055 .055 .055

.080 .080 .080

2.0 2.0 2.0

1.340 1.340 1.480

34.0 34.0 37.6

1707 1778 2203

2543 2649 3282

40-XLPO-3 40-XLPO-3G 40-XLPO-4

3 3+GRD 4

4/0 4/0 4/0

19 19 19

4 -

.055 .055 .055

.080 .080 .110

2.0 2.0 2.8

1.580 1.580 1.810

40.1 40.1 46.0

2578 2734 3455

3841 4046 5113

350-XLPO-3 350-XLPO-3G 350-XLPO-4

3 3+GRD 4

350 350 350

37 37 37

3 -

.065 .065 .065

.110 .110 .110

2.8 2.8 2.8

2.030 2.030 2.240

51.6 51.6 56.9

4251 4385 5505

6291 6490 8147

500-XLPO-3 3 500-XLPO-3G 3+GRD 500-XLPO-4 4

500 500 500

37 37 37

2 -

.065 .065 .065

.110 .110 .110

2.8 2.8 2.8

2.320 2.320 2.740

58.9 58.9 69.6

5869 6092 7668

8686 9016 11349

750-XLPO-3 750-XLPO-3G

750 750

61 61

1

.080 .080

.140 .140

3.6 3.6

2.860 2.860

72.6 72.6

8730 8976

12920 13284

3 3+GRD

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 507 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Control Cable FR-XLPE Insulated Conductors Smooth Helical Bare Copper Tape Shield, Low Smoke Halogen Polyolefin XLPO Jacket, 600V Applications Control or signal cable for important circuits in industrial plants and station control cable for electric utilities where flame resistance is essential. Suitable for the operation and interconnection of protective devices; rated circuit voltage 600V; recommended for operation at 90°C maximum continuous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Utility grade meets or exceeds all UL requirements. Construction Stranded coated copper conductors. The insulation shall be either fire retardant ethylene propylene rubber (FR-EPR) or fire retardant cross-linked Polyethylene (FR-XLPE). ICEA Appendix E Method 1 color-coded, conductors twisted with suitable fillers, helically applied copper tape shield, XLPO jacket overall, surface printed. Standards • TC Type Tray Cable per Article 340 of the NEC. • Individual conductors pass UL Standard 44 and the VW-1 vertical flame test. • Individual conductors approved as Type XHHW. • Cables Pass IEEE-383 ribbon burner flame test. • Overall jacket approved as Sunlight Resistant. • Cables meet requirements of ICEA S-73-532, NEMA WC57 for control cables. Notes • Cables may be supplied with an insulated ground and marked “Open Wiring.” • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request. Options • Bare or Tinned Copper • Flexible stranded conductors • Color Coding: ICEA Method 1, Table E-1 • EPR Insulation • PVC, CPE, CSPE Jackets • Insulated ground wires or bare ground wires • Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications.

CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

508 20150508

Control Cable FR-XLPE Insulated Conductors Smooth Helical Bare Copper Tape Shield, Low Smoke Halogen Polyolefin XLPO Jacket, 600V Item #

Number of Conductors

Conductor Size AWG

Conductor Stranding

Copper Shield Thickness (in)

Copper Shield Thickness (mm)

Nominal Jacket Thickness (in)

Nominal Jacket Thickness (mm)

Nominal Cable O.D. (in)

Nominal Cable O.D. (mm)

Approx. Cable Weight /MFT (lb)

Approx. Cable Weight /Km (kg)

14-402SHX 14-403SHX 14-404SHX 14-405SHX 14-407SHX 14-409SHX 14-412SHX

2 3 4 5 7 9 12

14 14 14 14 14 14 14

7 7 7 7 7 7 7

.005 .005 .005 .005 .005 .005 .005

0.13 0.13 0.13 0.13 0.13 0.13 0.13

.045 .045 .045 .060 .060 .060 .060

1.1 1.1 1.1 1.5 1.5 1.5 1.5

0.445 0.470 0.505 0.580 0.620 0.705 0.785

11.3 11.9 12.8 14.7 15.7 17.9 19.9

109 132 155 207 246 311 393

162 196 231 308 366 463 585

12-452SHX 12-453SHX 12-454SHX 12-455SHX 12-457SHX 12-459SHX 12-462SHX

2 3 4 5 7 9 12

12 12 12 12 12 12 12

7 7 7 7 7 7 7

.005 .005 .005 .005 .005 .005 .005

0.13 0.13 0.13 0.13 0.13 0.13 0.13

.045 .045 .060 .060 .060 .060 .080

1.1 1.1 1.5 1.5 1.5 1.5 2.0

0.485 0.510 0.585 0.630 0.675 0.775 0.905

12.3 13.0 14.9 16.0 17.1 19.7 23.0

137 163 225 259 322 409 552

204 243 335 385 479 609 821

10-502SHX 10-503SHX 10-504SHX 10-505SHX 10-507SHX 10-509SHX 10-512SHX

2 3 4 5 7 9 12

10 10 10 10 10 10 10

7 7 7 7 7 7 7

.005 .005 .005 .005 .005 .005 .005

0.13 0.13 0.13 0.13 0.13 0.13 0.13

.045 .060 .060 .060 .060 .080 .080

1.1 1.5 1.5 1.5 1.5 2.0 2.0

0.535 0.595 0.640 0.695 0.750 0.910 1.010

13.6 15.1 16.3 17.7 19.1 23.1 25.7

179 234 289 340 442 590 748

266 348 430 506 658 878 1113

CONTROL CABLES

*Part numbers are for XLPO jacketed cables only.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 508 20150508

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Control Cable FR-XLPE Insulated Conductors Longitudinal Corrugated Bare Copper Tape Shield, Low Smoke Halogen Polyolefin XLPO Jacket, 600V Applications Control or signal cable for important circuits in industrial plants and station control cable for electric utilities where flame resistance is essential. Suitable for the operation and interconnection of protective devices; rated circuit voltage 600 volts; recommended for operation at 90°C maximum continuous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Specifications • Conductors conform to ASTM B-3 & B-8. • Insulation conforms to UL Standard 44. • TC Type Tray Cable per Article 340 of the NEC. • Cables designed to pass the IEEE-383 & IEEE-1202 tests. • Jacket suitable for Sunlight Resistant applications. • Cables meet requirements of ICEA S-73-532 and ICEA S-95-658/NEMA WC70. Construction Stranded copper conductors, XLP insulated, Method 1 - Table E1 or E2 color coded or Method 4 phase-identified, conductors twisted with suitable fillers, Longitudinal Corrugated Bare Copper Tape Shield, LSZH jacket overall, surface printed. Options Also available with -G Ground Wire, -SH Mylar Aluminum Foil Shield, No Shield Notes Dimensional data not binding, we reserve the right to alter specifications without notice. SHIPPING TOLERANCE +/- 10%

Item #

O.A. (mil)

O.D. (mil)

Weight /MFT (lb)

2 3 4 5 7 9 12 15 19 25 31 37

45 45 45 45 45 45 45 60 60 60 80 80

0.3 0.3 0.4 0.4 0.5 0.5 0.6 0.6 0.8 0.9 0.9 1

58 75 93 114 135 172 202 229 262 323 377 448

16-02XLOHS 16-03XLOHS 16-04XLOHS 16-05XLOHS 16-07XLOHS 16-09XLOHS 16-12XLOHS 16-15XLOHS 16-19XLOHS 16-25XLOHS 16-31XLOHS 16-37XLOHS

16 16 16 16 16 16 16 16 16 16 16 16

2 3 4 5 7 9 12 15 19 25 31 37

45 45 45 60 60 60 60 80 80 80 80 80

0.4 0.4 0.4 0.4 0.5 0.6 0.6 0.7 0.7 0.8 0.9 1

69 84 104 119 140 181 246 302 352 469 590 675

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

531 20150508

CONTROL CABLES

Number of Conductors

18-02XLOHS 18-03XLOHS 18-04XLOHS 18-05XLOHS 18-07XLOHS 18-09XLOHS 18-12XLOHS 18-15XLOHS 18-19XLOHS 18-25XLOHS 18-31XLOHS 18-37XLOHS

Cond. Size AWG or or kcmil 18 18 18 18 18 18 18 18 18 18 18 18

Control Cable FR-XLPE Insulated Conductors Longitudinal Corrugated Bare Copper Tape Shield, Low Smoke Halogen Polyolefin XLPO Jacket, 600V

CONTROL CABLES

Item #

Cond. Size AWG or or kcmil

Number of Conductors

O.A. (mil)

O.D. (mil)

Weight /MFT (lb)

14-02XLOHS 14-03XLOHS 14-04XLOHS 14-05XLOHS 14-07XLOHS 14-09XLOHS 14-12XLOHS 14-15XLOHS 14-19XLOHS 14-25XLOHS 14-31XLOHS 14-37XLOHS

14 14 14 14 14 14 14 14 14 14 14 14

2 3 4 5 7 9 12 15 19 25 31 37

45 45 45 45 45 60 60 60 60 80 80 80

0.4 0.4 0.5 0.5 0.5 0.7 0.7 0.8 0.8 1 1.1 1.2

88 109 134 155 210 296 353 450 529 740 881 1015

12-02XLOHS 12-03XLOHS 12-04XLOHS 12-05XLOHS 12-07XLOHS 12-09XLOHS 12-12XLOHS 12-15XLOHS 12-19XLOHS 12-25XLOHS 12-31XLOHS 12-37XLOHS

12 12 12 12 12 12 12 12 12 12 12 12

2 3 4 5 7 9 12 15 19 25 31 37

45 45 45 45 60 60 60 80 80 80 80 80

0.5 0.5 0.5 0.6 0.6 0.7 0.8 0.9 1 1.1 1.2 1.3

119 144 180 235 295 387 498 653 759 1021 1217 1413

10-02XLOHS 10-03XLOHS 10-04XLOHS 10-05XLOHS 10-07XLOHS 10-09XLOHS 10-12XLOHS 10-15XLOHS 10-19XLOHS 10-25XLOHS 10-31XLOHS 10-37XLOHS

10 10 10 10 10 10 10 10 10 10 10 10

2 3 4 5 7 9 12 15 19 25 31 37

45 45 60 60 60 60 80 80 80 80 80 80

0.5 0.5 0.6 0.7 0.7 0.8 1 1.1 1.1 1.3 1.4 1.5

169 205 275 331 422 537 738 904 1080 1431 1724 2005

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 531 20150508

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Control Cable FR-EPR Insulated Conductors PVC Jacket, 600V Applications As flame-retardant multi-conductor control, signal or power cables rated 600V, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Construction Stranded uncoated copper conductors, 30 mils Flame Retardant Ethylene Propylene Rubber (FREPR) insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, cable tape, PVC jacket overall, surface printed. Standards • Listed by UL as Type TC per Standard 1277 for Tray Cables. • Cables UL listed for Direct Burial. • Individual conductors pass UL VW-1 flame test. • Individual conductors UL listed as Type XHHW-2. • Overall jacket UL listed as Sunlight Resistant. • Cables with grounding conductor UL listed for Open Wiring. • Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test. • Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test. • Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables. Notes • Cables may be supplied with an insulated ground and marked “Open Wiring.” • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request. Options • Bare or Tinned Copper • Flexible stranded conductors • Color Coding: ICEA Method 1, Table E-1 • FRXLP Insulation • CPE, CSPE, LSOH Jackets • Insulated ground wires or bare ground wires • Overall copper tape shield • Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications. CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

509 20140110

Control Cable FR-EPR Insulated Conductors PVC Jacket, 600V Item #

Size Conductor Ground Nominal Nominal Nominal Nominal Nominal Nominal AWG Strand Wire Insulation Insulation Jacket Jacket Cable Cable Size Thickness Thickness Thickness Thickness O.D. O.D. AWG (in) (mm) (in) (mm) (in) (mm) 14-E-PVC-2-FLAT 2 FLAT 14 7/.0242 0.030 0.76 0.045 1.14 .365x.230 9.30x5.80

CONTROL CABLES

14-E-PVC-3 14-E-PVC-4 14-E-PVC-5 14-E-PVC-7 14-E-PVC-9 14-E-PVC-12 14-E-PVC-19 14-E-PVC-25 14-E-PVC-30 14-E-PVC-37

3 4 5 7 9 12 19 25 30 37

0.390 0.425 0.465 0.505 0.620 0.700 0.815 0.935 1.030 1.110

9.910 10.800 11.810 12.830 15.750 17.780 20.700 23.750 26.160 28.190

Copper Weight /MFT (lb) 26

Copper Weight /km (kg) 38

Approx. Weight /MFT (lb) 61

Approx. Weight /km (kg) 91

39 53 66 92 118 158 250 323 387 466

59 78 98 137 176 235 372 481 576 694

92 115 139 173 240 301 468 624 747 875

137 171 207 257 357 448 696 929 1112 1302

14 14 14 14 14 14 14 14 14 14

7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.080 0.080 0.080

1.14 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 2.03

12-E-PVC-2-FLAT 2 FLAT 12-E-PVC-2 2 12-E-PVC-3 3 12-E-PVC-4 4 12-E-PVC-5 5 12-E-PVC-7 7 12-E-PVC-9 9 12-E-PVC-12 12 12-E-PVC-19 19 12-E-PVC-25 25 12-E-PVC-30 30 12-E-PVC-37 37

12 12 12 12 12 12 12 12 12 12 12 12

7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.080 0.080 0.080 0.080

1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 2.03 2.03

.400x.245 10.20x6.20 0.410 10.410 0.435 11.050 0.475 12.070 0.520 13.210 0.595 15.110 0.695 17.650 0.765 19.430 0.940 23.880 1.095 27.810 1.150 29.210 1.240 31.500

42 42 64 85 106 149 191 247 391 515 618 762

63 63 95 127 158 221 285 368 582 767 920 1134

82 94 124 157 191 268 337 428 688 854 1002 1240

122 140 185 234 284 399 502 637 1024 1271 1491 1845

10-E-PVC-2-FLAT 2 FLAT 10-E-PVC-2 2 10-E-PVC-3 3 10-E-PVC-4 4 10-E-PVC-5 5 10-E-PVC-7 7 10-E-PVC-9 9 10-E-PVC-12 12

10 10 10 10 10 10 10 10

7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.080

1.14 1.14 1.14 1.52 1.52 1.52 1.52 2.03

.445x.270 0.455 0.485 0.560 0.615 0.670 0.760 0.950

64 65 100 134 167 234 295 402

95 97 150 199 249 349 440 598

113 128 172 234 284 381 464 651

168 190 256 348 423 567 691 969

11.30x6.90 11.560 12.320 14.220 15.620 17.020 19.300 22.990

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 509 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Power Cable EPR Insulated Conductors PVC Jacket, 600V Applications As flame-retardant three or four conductor power cables rated 600V, 90°C. in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC cable is also approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, or direct buried. Construction Class B stranded tinned annealed copper conductor, Flame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II surface print phase identification. Color-coded per ICEA Method 4; individual conductors colored black with conductor number surface printed in contrasting ink with a Class B stranded uninsulated tinned annealed copper grounding conductor and PVC jacket overall, surface printed. Standards • UL 44 Type XHHW-2 • UL 1277 Type TC-ER, UL File # E57179 • UL 1581 • ICEA S-95-658/NEMA WC70 • UL 1581 VW-1 • UL 1277 • IEEE 383 • IEEE 1202 • CSA FT4 • ICEA T-29-520 • Color Coding ICEA Method 4 Notes • Ampacity in accordance with the National Electrical Code for cables in uncovered cable tray without maintained spacing and for cables in raceway or directly buried; at the conductor temperature indicated, in wet or dry locations, 30°C ambient temperature. • Grounding conductor per UL Standard 1277 for Type TC Tray Cable.

CONTROL CABLES

Options • Bare or Tinned Copper • Flexible stranded conductors • E1 or E2 color codes • FRXLP Insulation • CPE, CSPE, LSOH Jackets • Insulated ground wires or bare ground wires • Overall copper tape shield • Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

510 20140110

Power Cable EPR Insulated Conductors PVC Jacket, 600V

CONTROL CABLES

Item #

Number of Size Conductors AWG

Conductor Ground Nominal Nominal Nominal Nominal Strand Wire Insulation Insulation Jacket Jacket Size Thickness Thickness Thickness Thickness AWG (in) (mm) (in) (mm) 7/.0242 14 0.030 0.76 0.045 1.14 7/.0305 12 0.030 0.76 0.045 1.14 7/.0385 10 0.030 0.76 0.060 1.52

Nominal Nominal Cable Cable O.D. O.D. (in) (mm) 0.430 10.92 0.480 12.19 0.565 14.35

Copper Weight /MFT (lb) 55 87 136

Copper Weight /km (kg) 82 129 202

Approx. Weight /MFT (lb) 118 160 237

Approx. Weight /Km (kg) 176 238 353

3REPR-14 3REPR-12 3REPR-10

3 3 3

14 12 10

3REPR-8 4REPR-8

3 4

8 8

7/.0486 7/.0486

10 10

0.045 0.045

1.14 1.14

0.060 0.060

1.52 1.52

0.655 0.720

16.64 18.29

190 242

283 360

314 393

467 585

3REPR-6 4REPR-6

3 4

6 6

7/.0612 7/.0612

8 8

0.045 0.045

1.14 1.14

0.00 0.060

1.52 1.52

0.740 0.790

18.80 20.07

297 384

442 571

456 561

679 835

3REPR-4 4REPR-4

3 4

4 4

7/.0772 7/.0772

8 8

0.045 0.045

1.14 1.14

0.080 0.080

2.03 2.03

0.880 0.950

22.35 24.13

442 578

658 861

642 822

955 1223

3REPR-2 4REPR-2

3 4

2 2

7/.0974 7/.0974

6 6

0.045 0.045

1.14 1.14

0.080 0.080

2.03 2.03

1.010 1.090

25.65 27.69

703 919

1046 1368

979 1235

1457 1838

3REPR-1 4REPR-1

3 4

1 1

19/.0664 19/.0664

6 6

0.055 0.055

1.40 1.40

0.080 0.080

2.03 2.03

1.120 1.235

28.45 31.37

872 1136

1298 1691

1021 1521

1594 2264

3REPR-1/0 4REPR-1/0

3 4

1/0 1/0

19/.0745 19/.0745

6 6

0.055 0.055

1.40 1.40

0.080 0.080

2.03 2.03

1.225 1.330

31.12 33.78

1069 1413

1591 2103

1439 1820

2142 2709

3REPR-2/0 4REPR-2/0

3 4

2/0 2/0

19/.0837 19/.0837

6 6

0.055 0.055

1.40 1.40

0.080 0.080

2.03 2.03

1.300 1.440

33.02 36.58

1340 1760

1994 2619

1720 2208

2560 3286

3REPR-3/0 4REPR-3/0

3 4

3/0 3/0

19/.0940 19/.0940

4 4

0.055 0.055

1.40 1.40

0.080 0.080

2.03 2.03

1.420 1.570

36.07 39.88

1717 2245

2555 3341

2176 2788

3238 3405

3REPR-4/0 4REPR-4/0

3 4

4/0 4/0

19/.1055 19/.1055

4 4

0.055 0.055

1.40 1.40

0.080 0.110

2.03 2.79

1.540 1.790

39.12 45.47

2130 2796

3170 4161

2614 3495

3890 5201

3REPR-250 4REPR-250

3 4

250 250

37/.0822 37/.0822

4 4

0.065 0.065

1.65 1.65

0.110 0.110

2.79 2.79

1.760 1.915

44.70 48.64

2494 3282

3712 4884

3184 4019

4738 5981

3REPR-350 4REPR-350

3 4

350 350

37/.0973 37/.0973

3 3

0.065 0.065

1.65 1.65

0.110 0.110

2.79 2.79

1.960 2.165

49.78 54.99

3474 4577

5170 6811

4187 5436

6231 8090

3REPR-500 4REPR-500

3 4

500 500

37/.1162 37/.1162

2 2

0.065 0.065

1.65 1.65

0.110 0.110

2.79 2.79

2.245 2.475

57.02 62.87

4934 6509

7343 9687

5847 7607

8702 11321

3REPR-750 4REPR-750

3 4

750 750

61/.1109 61/.1109

1 1

0.080 0.080

2.03 2.03

0.140 0.140

3.56 3.56

2.810 3.115

71.37 79.12

7278 9712

10831 14453

9145 11805

13610 17569

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 510 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Control Cable FR-EPR Insulated Conductors CPE Jacket, 600V Applications As flame-retardant multi-conductor control, signal or power cables rated 600V, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class I remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Construction Stranded uncoated copper conductors, 30 mils Flame Retardant Ethylene Propylene Rubber (FREPR) insulation, color coded, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, cable tape, CPE jacket overall, surface printed. Standards • Listed by UL as Type TC per Standard 1277 for Tray Cables. • Cables UL listed for Direct Burial. • Individual conductors pass UL VW-1 flame test. • Individual conductors UL listed as Type XHHW-2. • Overall jacket UL listed as Sunlight Resistant. • Cables with grounding conductor UL listed for Open Wiring. • Cables pass IEEE-383 ribbon burner flame test and ICEA 210,000 BTU/hr test. • Cables pass IEEE1202/CSA FT4 (70,000 BTU/hr) cable tray flame test. • Cables meet requirements of ICEA S-73-532, NEMA WC57 for Control Cables. Notes • Cables may be supplied with an insulated ground and marked “Open Wiring.” • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request. Options • Bare or Tinned Copper • Flexible stranded conductors • Color Coding ICEAA Method 1, Table E-1 • FRXLP Insulation • PVC, CSPE, LSOH Jackets • Insulated ground wires or bare ground wires • Overall copper tape shield • Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications. CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

511 20140110

Control Cable FR-EPR Insulated Conductors CPE Jacket, 600V

CONTROL CABLES

Item #

Size Conductor Ground Nominal Nominal Nominal Nominal Nominal AWG Strand Wire Insulation Insulation Jacket Jacket Cable Size Thickness Thickness Thickness Thickness O.D. AWG (in) (mm) (in) (mm) (in)

Nominal Cable O.D. (mm)

Copper Weight /MFT (lb)

Copper Weight /km (kg)

Approx. Weight /MFT (lb)

Approx. Weight /km (kg)

14-E-CPE-2-FLAT 2 FLAT 14-E-CPE-3 3 14-E-CPE-4 4 14-E-CPE-5 5 14-E-CPE-7 7 14-E-CPE-9 9 14-E-CPE-12 12 14-E-CPE-19 19 14-E-CPE-25 25 14-E-CPE-30 30 14-E-CPE-37 37

14 14 14 14 14 14 14 14 14 14 14

7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242 7/.0242

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.080 0.080 0.080

1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 2.03

.365x.230 0.390 0.425 0.465 0.505 0.620 0.700 0.815 0.935 1.030 1.110

9.30x5.80 9.910 10.800 11.810 12.830 15.750 17.780 20.700 23.750 26.160 28.190

26 39 53 66 92 118 158 250 323 387 466

38 59 78 98 137 176 235 372 481 576 694

61 92 115 139 173 240 301 468 624 747 875

91 137 171 207 257 357 448 696 929 1112 1302

12-E-CPE-2-FLAT 2 FLAT 12-E-CPE-2 2 12-E-CPE-3 3 12-E-CPE-4 4 12-E-CPE-5 5 12-E-CPE-7 7 12-E-CPE-9 9 12-E-CPE-12 12 12-E-CPE-19 19 12-E-CPE-25 25 12-E-CPE-30 30 12-E-CPE-37 37

12 12 12 12 12 12 12 12 12 12 12 12

7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305 7/.0305

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.080 0.080 0.080 0.080

1.14 1.14 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 2.03 2.03

.400x.245 10.20x6.20 0.410 10.410 0.435 11.050 0.475 12.070 0.520 13.210 0.595 15.110 0.695 17.650 0.765 19.430 0.940 23.880 1.095 27.810 1.150 29.210 1.240 31.500

42 42 64 85 106 149 191 247 391 515 618 762

63 63 95 127 158 221 285 368 582 767 920 1134

82 94 124 157 191 268 337 428 688 854 1002 1240

122 140 185 234 284 399 502 637 1024 1271 1491 1845

10-E-CPE-2-FLAT 2 FLAT 10-E-CPE-2 2 10-E-CPE-3 3 10-E-CPE-4 4 10-E-CPE-5 5 10-E-CPE-7 7 10-E-CPE-9 9 10-E-CPE-12 12

10 10 10 10 10 10 10 10

7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385 7/.0385

0.030 0.030 0.030 0.030 0.030 0.030 0.030 0.030

0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76

0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.080

1.14 1.14 1.14 1.52 1.52 1.52 1.52 2.03

.445x.270 0.455 0.485 0.560 0.615 0.670 0.760 0.950

64 65 100 134 167 234 295 402

95 97 150 199 249 349 440 598

113 128 172 234 284 381 464 651

168 190 256 348 423 567 691 969

11.30x6.90 11.560 12.320 14.220 15.620 17.020 19.300 22.990

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 511 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Power Cable EPR Insulated Conductors CPE Jacket, 600V Applications As flame-retardant three or four conductor power cables rated 600V, 90°C in wet or dry locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC cable is also approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, or direct buried. Construction Class B stranded tinned annealed copper conductor, Flame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II surface print phase identification. Color-coded per ICEA Method 4; individual conductors colored black with conductor number surface printed in contrasting ink with a Class B stranded uninsulated tinned annealed copper grounding conductor and CPE jacket overall, surface printed. Standards • UL 44 Type XHHW-2 • UL 1277 Type TC-ER, UL File # E57179 • UL 1581 • ICEA S-95-658/NEMA WC70 • UL 1581 VW-1 • UL 1277 • IEEE 383 • IEEE 1202 • CSA FT4 • ICEA T-29-520 • Color Code ICEA Method 4 Notes • Ampacity in accordance with the National Electrical Code for cables in uncovered cable tray without maintained spacing and for cables in raceway or directly buried; at the conductor temperature indicated, in wet or dry locations, 30°C ambient temperature. • Grounding conductor per UL Standard 1277 for Type TC Tray Cable.

CONTROL CABLES

Options • Bare or Tinned Copper • Flexible stranded conductors • E1 or E2 color codes • FRXLP Insulation • PVC, CSPE, LSOH Jackets • Insulated ground wires or bare ground wires • Overall copper tape shield • Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

512 20140110

Power Cable EPR Insulated Conductors CPE Jacket, 600V

CONTROL CABLES

Item #

Number of Size Conductors AWG

Conductor Ground Nominal Nominal Nominal Nominal Strand Wire Insulation Insulation Jacket Jacket Size Thickness Thickness Thickness Thickness AWG (in) (mm) (in) (mm) 7/.0242 14 0.0300 0.76 0.045 1.14 7/.0305 12 0.0300 0.76 0.045 1.14 7/.0385 10 0.0300 0.76 0.060 1.52

Nominal Nominal Cable Cable O.D. O.D. (in) (mm) 0.430 10.92 0.480 12.19 0.565 14.35

Copper Weight /MFT (lb) 55 87 136

Copper Weight /km (kg) 82 129 202

Approx. Weight /MFT (lb) 118 160 237

Approx. Weight /Km (kg) 176 238 353

3EEPR-14 3EEPR-12 3EEPR-10

3 3 3

14 12 10

3EEPR-8 4EEPR-8

3 4

8 8

7/.0486 7/.0486

10 10

0.045 0.045

1.14 1.14

0.060 0.060

1.52 1.52

0.655 0.720

16.64 18.29

190 242

283 360

314 393

467 585

3EEPR-6 4EEPR-6

3 4

6 6

7/.0612 7/.0612

8 8

0.045 0.045

1.14 1.14

0.060 0.060

1.52 1.52

0.740 0.790

18.80 20.07

297 384

442 571

456 561

679 835

3EEPR-4 4EEPR-4

3 4

4 4

7/.0772 7/.0772

8 8

0.045 0.045

1.14 1.14

0.080 0.080

2.03 2.03

0.880 0.950

22.35 24.13

442 578

658 861

642 822

955 1223

3EEPR-2 4EEPR-2

3 4

2 2

7/.0974 7/.0974

6 6

0.045 0.045

1.14 1.14

0.080 0.080

2.03 2.03

1.010 1.090

25.65 27.69

703 919

1046 1368

979 1235

1457 1838

3EEPR-1 4EEPR-1

3 4

1 1

19/.0664 19/.0664

6 6

0.055 0.055

1.40 1.40

0.080 0.080

2.03 2.03

1.120 1.235

28.45 31.37

872 1136

1298 1691

1021 1521

1594 2264

3EEPR-1/0 4EEPR-1/0

3 4

1/0 1/0

19/.0745 19/.0745

6 6

0.055 0.055

1.40 1.40

0.080 0.080

2.03 2.03

1.225 1.330

31.12 33.78

1069 1413

1591 2103

1439 1820

2142 2709

3EEPR-2/0 4EEPR-2/0

3 4

2/0 2/0

19/.0837 19/.0837

6 6

0.055 0.055

1.40 1.40

0.080 0.080

2.03 2.03

1.300 1.440

33.02 36.58

1340 1760

1994 2619

1720 2208

2560 3286

3EEPR-3/0 4EEPR-3/0

3 4

3/0 3/0

19/.0940 19/.0940

4 4

0.055 0.055

1.40 1.40

0.080 0.080

2.03 2.03

1.420 1.570

36.07 39.88

1717 2245

2555 3341

2176 2788

3238 3405

3EEPR-4/0 4EEPR-4/0

3 4

4/0 4/0

19/.1055 19/.1055

4 4

0.055 0.055

1.40 1.40

0.080 0.110

2.03 2.79

1.540 1.790

39.12 45.47

2130 2796

3170 4161

2614 3495

3890 5201

3EEPR-250 4EEPR-250

3 4

250 250

37/.0822 37/.0822

4 4

0.065 0.065

1.65 1.65

0.110 0.110

2.79 2.79

1.760 1.915

44.70 48.64

2494 3282

3712 4884

3184 4019

4738 5981

3EEPR-350 4EEPR-350

3 4

350 350

37/.0973 37/.0973

3 3

0.065 0.065

1.65 1.65

0.110 0.110

2.79 2.79

1.960 2.165

49.78 54.99

3474 4577

5170 6811

4187 5436

6231 8090

3EEPR-500 4EEPR-500

3 4

500 500

37/.1162 37/.1162

2 2

0.065 0.065

1.65 1.65

0.110 0.110

2.79 2.79

2.245 2.475

57.02 62.87

4934 6509

7343 9687

5847 7607

8702 11321

3EEPR-750 4EEPR-750

3 4

750 750

61/.1109 61/.1109

1 1

0.080 0.080

2.03 2.03

0.140 0.140

3.56 3.56

2.810 3.115

71.37 79.12

7278 9712

10831 14453

9145 11805

13610 17569

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 512 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Control Cable FR-EPR Insulated Conductors Copper Shield, CPE Jacket, 600V Applications Control or signal cable for important circuits in industrial plants and station control cable for electric utilities where flame resistance is essential. Suitable for the operation and interconnection of protective devices; rated circuit voltage 600V; recommended for operation at 90°C maximum continuous conductor temperature in wet or dry locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Utility grade meets or exceeds all UL requirements. Construction Stranded coated copper conductors. The insulation shall be either fire retardant ethylene propylene rubber (EPR) or fire retardant cross-linked Polyethylene (FR-XLPE). ICEA Appendix E Method 1 colorcoded, conductors twisted with suitable fillers, helically applied copper tape shield, CPE jacket overall, surface printed. Standards • TC Type Tray Cable per Article 340 of the NEC. • Individual conductors pass UL Standard 44 and the VW-1 vertical flame test. • Individual conductors approved as Type XHHW. • Cables Pass IEEE-383 ribbon burner flame test. • Overall jacket approved as Sunlight Resistant. • Cables meet requirements of ICEA S-73-532/NEMA WC57 for control cables. Notes • Cables may be supplied with an insulated ground and marked “Open Wiring.” • Standard color coding is Method 1 for NEC applications per Appendix E, Table E-2 of ICEA S-73532(TECH I006). This color coding method omits white and green from the color sequence. A white or green conductor can be supplied on request. Options • Bare or Tinned Copper • Flexible stranded conductors • Color Coding: ICEA Method 1, Table E-1 • FRXLP Insulation • PVC, CSPE, LSOH Jackets • Insulated ground wires or bare ground wires • Overall copper braid shield • Overall longitudinal corrugated copper shield • Overall mylar tape shield with drain wire • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications.

CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

513 20140110

Control Cable FR-EPR Insulated Conductors Copper Shield, CPE Jacket, 600V

CONTROL CABLES

Item #

Number of Conductors

Conductor Size AWG

Conductor Stranding

Copper Shield Thickness (in)

Copper Shield Thickness (mm)

Nominal Jacket Thickness (in)

Nominal Jacket Thickness (mm)

Nominal Cable O.D. (in)

Nominal Cable O.D. (mm)

Approx. Cable Weight /MFT (lb)

Approx. Cable Weight /Km (kg)

14-402ESH 14-403ESH 14-404ESH 14-405ESH 14-407ESH 14-409ESH 14-412ESH

2 3 4 5 7 9 12

14 14 14 14 14 14 14

7 7 7 7 7 7 7

.005 .005 .005 .005 .005 .005 .005

0.13 0.13 0.13 0.13 0.13 0.13 0.13

.045 .045 .045 .060 .060 .060 .060

1.1 1.1 1.1 1.5 1.5 1.5 1.5

0.445 0.470 0.505 0.580 0.620 0.705 0.785

11.3 11.9 12.8 14.7 15.7 17.9 19.9

109 132 155 207 246 311 393

162 196 231 308 366 463 585

12-452ESH 12-453ESH 12-454ESH 12-455ESH 12-457ESH 12-459ESH 12-462ESH

2 3 4 5 7 9 12

12 12 12 12 12 12 12

7 7 7 7 7 7 7

.005 .005 .005 .005 .005 .005 .005

0.13 0.13 0.13 0.13 0.13 0.13 0.13

.045 .045 .060 .060 .060 .060 .080

1.1 1.1 1.5 1.5 1.5 1.5 2.0

0.485 0.510 0.585 0.630 0.675 0.775 0.905

12.3 13.0 14.9 16.0 17.1 19.7 23.0

137 163 225 259 322 409 552

204 243 335 385 479 609 821

10-502ESH 10-503ESH 10-504ESH 10-505ESH 10-507ESH 10-509ESH 10-512ESH

2 3 4 5 7 9 12

10 10 10 10 10 10 10

7 7 7 7 7 7 7

.005 .005 .005 .005 .005 .005 .005

0.13 0.13 0.13 0.13 0.13 0.13 0.13

.045 .060 .060 .060 .060 .080 .080

1.1 1.5 1.5 1.5 1.5 2.0 2.0

0.535 0.595 0.640 0.695 0.750 0.910 1.010

13.6 15.1 16.3 17.7 19.1 23.1 25.7

179 234 289 340 442 590 748

266 348 430 506 658 878 1113

08-552ESH 08-553ESH 08-554ESH

2 3 4

8 8 8

7 7 7

.005 .005 .005

0.13 0.13 0.13

.060 .060 .060

1.5 1.5 1.5

0.695 0.735 0.795

17.7 18.7 20.2

288 365 444

429 543 661

06-602ESH 06-603ESH 06-603ESH

2 3 4

6 6 6

7 7 7

.005 .005 .005

0.13 0.13 0.13

.060 .060 .080

1.5 1.5 2.0

0.775 0.820 0.935

19.7 20.8 23.4

378 494 645

562 735 956

04-502ESH 04-503ESH 04-554ESH

2 3 4

4 4 4

7 7 7

.005 .005 .005

0.13 0.13 0.13

.080 .080 .080

2.0 2.0 2.0

0.915 0.965 1.055

23.2 24.5 26.8

550 722 903

818 1074 1344

02-503ESH 02-554ESH 02-554ESH

2 3 4

2 2 2

7 7 7

.005 .005 .005

0.13 0.13 0.13

.080 .080 .080

2.0 2.0 2.0

1.035 1.100 1.200

26.3 27.9 30.5

758 1007 1288

1128 1498 1917

01-503ESH 01-554ESH

2 3

1 1

19 19

.005 .005

0.13 0.13

.080 .080

2.0 2.0

1.230 1.350

31.2 34.3

1236 1564

1839 2327

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 513 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

20/10 Control Cable PE/PVC Insulated Conductors PVC Jacket, 600V Applications Standard general purpose control cable for important control circuits in industrial plants and station control cable for utilities. Suitable for operation and interconnection of protective devices; rated circuit voltage 600V, recommended for operation at 75°C maximum continuous conductor temperature. For Non NEC Application Cables may be installed in open air, in ducts or conduit, or in tray or trough and direct burial. For metering installations where insulated conductors are subject to sunlight degradation, these cables can be jacketed with special UV-resistant compounds. Construction Stranded uncoated copper conductors, 20 mils black high molecular weight polyethylene insulation, 10 mils full color coded PVC Jacket over each insulated conductor, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, polyester tape over assembly, PVC jacket overall, surface printed. Standards Physical and electrical tests in accordance with appropriate sections of ICEA S-73-532, NEMA WC57. Notes • Single conductor 20 mils high molecular weight polyethylene insulation and 10 mils polyvinyl chloride jacket, 600V. • Color coding is ICEA Appendix E Method 1 Table E-1. Options • Flexible stranded conductors • Tin-coated copper conductors per ASTM B33 • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications.

Item #

Conductor Size AWG

Conductor Stranding

Nominal Jacket Thickness (in)

Nominal Jacket Thickness (mm)

Nominal Cable O.D. (in)

Nominal Cable O.D. (mm)

2 3 4 5 7 9 12 15 19 25 30 37

14 14 14 14 14 14 14 14 14 14 14 14

7 7 7 7 7 7 7 7 7 7 7 7

.045 .045 .045 .045 .045 .060 .060 .060 .060 .080 .080 .080

1.1 1.1 1.1 1.1 1.1 1.5 1.5 1.5 1.5 2.0 2.0 2.0

.235 x .375 0.400 0.435 0.475 0.515 0.640 0.710 0.785 0.825 1.030 1.065 1.150

5.97 x 9.53 10.2 11.0 12.1 13.1 16.3 18.0 19.9 21.0 26.2 27.1 29.2

Approximate Approximate Cable Weight Cable Weight /MFT /Km (lb) (kg) 63 95 117 132 174 238 305 370 453 624 693 832

93 141 173 195 258 352 451 548 670 924 1026 1231

CONTROL CABLES

14-CTB-2 14-CTB-3 14-CTB-4 14-CTB-5 14-CTB-7 14-CTB-9 14-CTB-12 14-CTB-15 14-CTB-19 14-CTB-25 14-CTB-30 14-CTB-37

Number of Conductors

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

514 20140110

20/10 Control Cable PE/PVC Insulated Conductors PVC Jacket, 600V

CONTROL CABLES

Item #

Number of Conductors

Conductor Size AWG

Conductor Stranding

Nominal Jacket Thickness (in)

Nominal Jacket Thickness (mm)

Nominal Cable O.D. (in)

Nominal Cable O.D. (mm)

Approximate Approximate Cable Weight Cable Weight /MFT /Km (lb) (kg)

12-CTB-2 12-CTB-3 12-CTB-4 12-CTB-5 12-CTB-7 12-CTB-9 12-CTB-12 12-CTB-15 12-CTB-19 12-CTB-25 12-CTB-30 12-CTB-37

2 3 4 5 7 9 12 15 19 25 30 37

12 12 12 12 12 12 12 12 12 12 12 12

7 7 7 7 7 7 7 7 7 7 7 7

.045 .045 .045 .045 .060 .060 .060 .080 .080 .080 .080 .080

1.1 1.1 1.1 1.1 1.5 1.5 1.5 2.0 2.0 2.0 2.0 2.0

.255 x .415 0.445 0.485 0.560 0.610 0.715 0.795 0.920 0.970 1.150 1.195 1.290

6.48 x 10.50 11.3 12.3 14.2 15.5 18.2 20.2 23.4 24.6 29.2 30.4 32.8

85 126 158 200 259 328 423 554 675 865 1020 1234

126 186 234 296 383 485 626 820 999 1280 1510 1826

10-CTB-2 10-CTB-3 10-CTB-4 10-CTB-5 10-CTB-7 10-CTB-9 10-CTB-12 10-CTB-15 10-CTB-19 10-CTB-25 10-CTB-30 10-CTB-37

2 3 4 5 7 9 12 15 19 25 30 37

10 10 10 10 10 10 10 10 10 10 10 10

7 7 7 7 7 7 7 7 7 7 7 7

.045 .045 .060 .060 .060 .060 .080 .080 .080 .080 .080 .080

1.1 1.1 1.5 1.5 1.5 1.5 2.0 2.0 2.0 2.0 2.0 2.0

.280 x .460 0.495 0.580 0.625 0.680 0.805 0.935 1.035 1.090 1.300 1.350 1.460

7.11 x 11.7 12.6 14.7 15.9 17.3 20.4 23.7 26.3 27.7 33.0 34.3 37.1

116 170 235 274 364 462 638 780 958 1245 1464 1778

171 252 348 406 539 684 944 1154 1418 1843 2167 2631

9-CTB-2 9-CTB-3 9-CTB-4 9-CTB-5 9-CTB-7 9-CTB-9 9-CTB-12 9-CTB-15 9-CTB-19 9-CTB-25 9-CTB-30 9-CTB-37

2 3 4 5 7 9 12 15 19 25 30 37

9 9 9 9 9 9 9 9 9 9 9 9

7 7 7 7 7 7 7 7 7 7 7 7

.045 .045 .060 .060 .060 .060 .080 .080 .080 .080 .080 .080

1.1 1.1 1.5 1.5 1.5 1.5 2.0 2.0 2.0 2.0 2.0 2.0

.290 x .490 0.520 0.600 0.660 0.720 0.845 0.985 1.095 1.150 1.380 1.430 1.545

7.37 x 12.4 13.2 15.2 16.8 18.3 21.5 25.0 27.8 29.2 35.1 36.3 39.2

132 188 258 313 418 530 731 896 1100 1433 1688 2050

195 278 382 463 619 784 1082 1326 1628 2121 2499 3034

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 514 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

20/10 Control Cable PE/PVC Insulated Conductors Shielded, PVC Jacket, 600V Applications Standard general purpose control cable for important control circuits in industrial plants and station control cable for utilities. Suitable for operation and interconnection of protective devices; rated circuit voltage 600V, recommended for operation at 75°C maximum continuous conductor temperature. For Non NEC Application Cables may be installed in open air, in ducts or conduit, or in tray or trough and direct burial. For metering installations where insulated conductors are exposed to sunlight degradations, these cables can be jacketed with special UV-resistant compounds. Construction Stranded uncoated copper conductors, 20 mils black high molecular weight polyethylene insulation, 10 mils full color coded PVC Jacket over each insulated conductor, two conductors flat, three or more conductors twisted with suitable fillers where necessary to make round, polyester tape over assembly, copper tape shield, PVC jacket overall, surface printed. Standards Physical and electrical tests in accordance with appropriate sections of ICEA S-73-532, NEMA WC57. Notes • Single conductor 20 mils high molecular weight polyethylene insulation and 10 mils polyvinyl chloride jacket, 600V. • Color coding is ICEA Appendix E Method 1 Table E-1. Options • Flexible stranded conductors • Tin-coated copper conductors per ASTM B33 • Copper braid shield • 1000V rated construction Consult AWG for a variety of alternate constructions for specific applications.

Item #

Conductor Size AWG

Conductor Stranding

Copper Shield Thickness (in)

Copper Shield Thickness (mm)

Nominal Jacket Thickness (in)

Nominal Jacket Thickness (mm)

Nominal Cable O.D. (in)

Nominal Cable O.D. (mm)

Approx. Cable Weight /MFT (lb)

Approx. Cable Weight /Km (kg)

10-CTB-2-S 10-CTB-3-S 10-CTB-4-S

2 3 4

10 10 10

7 7 7

.005 .005 .005

0.1 0.1 0.1

.060 .060 .060

1.5 1.5 1.5

0.600 0.640 0.695

15.2 16.3 17.7

233 285 333

345 423 493

9-CTB-3-S 9-CTB-4-S 9-CTB-5-S

3 4 5

9 9 9

7 7 7

.005 .005 .005

0.1 0.1 0.1

.060 .060 .060

1.5 1.5 1.5

0.620 0.670 0.725

15.7 17.0 18.4

258 318 377

382 471 558

8-CTB-3-S 8-CTB-4-S

3 4

8 8

7 7

.005 .005

0.1 0.1

.060 .080

1.5 2.0

0.805 0.920

20.4 23.4

391 511

579 756

6-CTB-3-S 6-CTB-4-S

3 4

6 6

7 7

.005 .005

0.1 0.1

.080 .080

2.0 2.0

0.980 1.065

24.9 27.1

585 722

866 1069

4-CTB-3-S 4-CTB-4-S

3 4

4 4

7 7

.005 .005

0.1 0.1

.080 .080

2.0 2.0

1.090 1.190

27.7 30.2

771 982

1141 1453

2-CTB-3-S 2-CTB-4-S

3 4

2 2

7 7

.005 .005

0.1 0.1

.080 .080

2.0 2.0

1.225 1.345

31.1 34.2

1076 1369

1592 2026

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

515 20140110

CONTROL CABLES

Number of Conductors

CONTROL CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

TFN, THWN or THHN Insulated Conductors PVC Jacket, 600V Applications As flame-retardant multi-conductor control, signal or power cables rated 600V, 90°C in dry locations, 75°C in wet locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class 1 remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, and are suitable for direct burial. Construction Individual conductors of stranded uncoated copper Type TFN (16AWG). Type THWN or THHN (14-10 AWG), color-coded, two conductors flat, three or more conductors twisted, PVC jacket overall, surface printed. Standards • Listed by UL as Type TC Tray Cable per Article 336 of the NEC. • Individual conductors UL listed as Type THWN or THHN (14-10 AWG) or Type TFN (16 AWG). • Overall jacket UL listed as Sunlight Resistant. • Cables UL listed for Direct Burial. • Cables with grounding conductor UL listed for Open Wiring. • Cables pass UL and IEEE-383 ribbon burner tests and ICEA 210.00 BTU/hr test. Notes • Cables designated (w/g) contain an additional bare copper grounding conductor, same size as circuit conductors, and are UL listed for Open Wiring. • Standard color-coding is ICEA Method E2 or K2 for NEC applications. This color-coding method omits white and green from the color sequence. • ICEA Method 4 color-coding is also provided. This consists of printed numbers and words, 1-ONE, 2-TWO, etc. • Size 16 AWG is rated 90°C dry only.

Item #

Size AWG

Number of Strands

Overall PVC Jacket (mil)

Nominal Diameter (in)

Weight /MFT (lb)

2 3 3 w/g 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 23 25

16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

45 45 N/A 45 45 45 45 45 45 45 45 60 60 60 60 60 60 60 60 60 60 60

.20 x .30 0.32 N/A 0.34 0.37 0.40 0.40 0.44 0.47 0.51 0.51 0.55 0.56 0.58 0.61 0.61 0.64 0.64 0.64 0.67 0.70 0.74

40 60 N/A 75 85 100 110 130 140 155 170 200 210 225 240 250 265 275 285 305 340 370

CONTROL CABLES

16-TC1-2 16-TC1-3 16-TC1-3 w/g 16-TC1-4 16-TC1-5 16-TC1-6 16-TC1-7 16-TC1-8 16-TC1-9 16-TC1-10 16-TC1-11 16-TC1-12 16-TC1-13 16-TC1-14 16-TC1-15 16-TC1-16 16-TC1-17 16-TC1-18 16-TC1-19 16-TC1-20 16-TC1-23 16-TC1-25

Number of Conductors

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

517 20140902

TFN, THWN or THHN Insulated Conductors PVC Jacket, 600V Item #

Number of Conductors

Size AWG

Number of Strands

Overall PVC Jacket (mil)

Nominal Diameter (in)

Weight /MFT (lb)

27 29 31 32 37

16 16 16 16 16

7 7 7 7 7

60 60 60 60 80

0.76 0.77 0.80 0.82 0.89

395 420 445 460 550

14-TC1-2 14-TC1-3 14-TC1-3 w/g 14-TC1-4 14-TC1-5 14-TC1-6 14-TC1-7 14-TC1-8 14-TC1-9 14-TC1-10 14-TC1-11 14-TC1-12 14-TC1-13 14-TC1-14 14-TC1-15 14-TC1-16 14-TC1-17 14-TC1-18 14-TC1-19 14-TC1-20 14-TC1-23 14-TC1-25 14-TC1-27 14-TC1-29 14-TC1-31 14-TC1-32 14-TC1-37

2 3 3 w/g 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 23 25 27 29 31 32 37

14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

45 45 45 45 45 45 45 45 45 60 60 60 60 60 60 60 60 60 60 60 60 80 80 80 80 80 80

.21 x .33 0.34 0.35 0.37 0.41 0.44 0.44 0.48 0.51 0.58 0.58 0.60 0.62 0.64 0.66 0.66 0.70 0.70 0.70 0.73 0.78 0.85 0.88 0.90 0.92 0.94 0.96

55 75 92 100 115 140 150 170 195 220 240 265 280 295 310 340 355 370 390 415 475 540 570 600 640 660 755

12-TC1-2 12-TC1-3 12-TC1-3 w/g 12-TC1-4 12-TC1-5 12-TC1-6 12-TC1-7 12-TC1-8 12-TC1-9 12-TC1-10 12-TC1-11 12-TC1-12

2 3 3 w/g 4 5 6 7 8 9 10 11 12

12 12 12 12 12 12 12 12 12 12 12 12

7 7 7 7 7 7 7 7 7 7 7 7

45 45 45 45 45 45 45 60 60 60 60 60

.23 x .37 0.36 0.40 0.40 0.45 0.50 0.50 0.58 0.62 0.66 0.66 0.68

75 105 130 135 165 195 215 260 300 325 350 375

CONTROL CABLES

16-TC1-27 16-TC1-29 16-TC1-31 16-TC1-32 16-TC1-37

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 517 20140902

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

TFN, THWN or THHN Insulated Conductors PVC Jacket, 600V Item #

12-TC1-13 12-TC1-14 12-TC1-15 12-TC1-16 12-TC1-17 12-TC1-18 12-TC1-19 12-TC1-20 12-TC1-23 12-TC1-25 12-TC1-27 12-TC1-29 12-TC1-31 12-TC1-32 12-TC1-37

Size AWG

Number of Strands

Overall PVC Jacket (mil)

Nominal Diameter (in)

Weight /MFT (lb)

13 14 15 16 17 18 19 20 23 25 27 29 31 32 37

12 12 12 12 12 12 12 12 12 12 12 12 12 12 12

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

60 60 60 60 60 60 60 80 80 80 80 80 80 80 80

0.70 0.73 0.76 0.76 0.79 0.79 0.79 0.89 0.93 0.96 1.00 1.01 1.06 1.08 1.10

400 425 455 485 515 545 656 590 690 770 840 910 950 1000 1090

2 3 3 w/g 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 23 25 27 29 31 32 37

10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

45 45 45 45 60 60 60 60 60 60 60 60 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80

.26 x .43 0.46 0.47 0.50 0.58 0.63 0.63 0.69 0.73 0.81 0.81 0.82 0.89 0.92 0.95 0.95 1.02 1.02 1.02 1.07 1.12 1.19 1.22 1.23 1.29 1.31 1.36

110 155 194 200 265 315 345 420 450 500 540 580 680 725 745 810 860 900 940 990 1120 1210 1295 1375 1465 1510 1710

CONTROL CABLES

10-TC1-2 10-TC1-3 10-TC1-3 w/g 10-TC1-4 10-TC1-5 10-TC1-6 10-TC1-7 10-TC1-8 10-TC1-9 10-TC1-10 10-TC1-11 10-TC1-12 10-TC1-13 10-TC1-14 10-TC1-15 10-TC1-16 10-TC1-17 10-TC1-18 10-TC1-19 10-TC1-20 10-TC1-23 10-TC1-25 10-TC1-27 10-TC1-29 10-TC1-31 10-TC1-32 10-TC1-37

Number of Conductors

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

517 20140902

CONTROL CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

TFN, THWN or THHN Insulated Conductors Overall Shield, Drain Wire, 600V Applications As flame-retardant multi-conductor control, signal or power cables rated 600V, 90°C in dry locations. 75°C in wet locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Also approved for use in Class 1 remote-control and signaling circuits per Article 725 of the NEC. Type TC cable is suitable for use in Class I and II, Division 2 hazardous locations. Cables may be installed in air, in ducts or conduits, in tray or trough, are suitable for direct burial. Construction Individual conductors of stranded uncoated copper Type TFN (16AWG). Type THWN or THHN (14-10 AWG), color-coded, cabled singles, overall aluminum/polyester foil tape plus tinned Cu drain wire, PVC jacket, surface printed. Standards • Listed by UL as Type TC Tray Cable per Article 336 of the NEC. • Individual conductors UL listed as Type THWN or THHN (14-10 AWG) or Type TFN (16 AWG). • Overall jacket UL listed as Sunlight Resistant. • Cables UL listed for Direct Burial. • Cables pass UL and IEEE-383 ribbon burner tests and ICEA 210.00 BTU/hr test. Notes • Drain wire 18 AWG on size 16 AWG conductor constructions, and 16 AWG on all other sizes. • Class 1 circuits as defined in Article 725. • Class 1, Division II Hazardous Locations per Article 501.4(B). • Aerial use permitted with a messenger. • Standard Color Coding also available ICEA Method 1, Table E-1

Item #

Size AWG

Number of Strands

Overall PVC Jacket (mil)

Nominal Diameter (in)

Weight /MFT (lb)

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 23 25 27 29 31 32 37

16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

45 45 45 45 45 45 45 45 45 45 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 80

0.32 0.32 0.34 0.37 0.40 0.40 0.44 0.47 0.51 0.51 0.55 0.56 0.58 0.61 0.61 0.64 0.64 0.64 0.67 0.70 0.74 0.76 0.77 0.80 0.82 0.89

54 60 75 85 100 110 130 140 155 170 200 210 225 240 250 265 275 285 305 340 370 395 420 445 460 550

CONTROL CABLES

16-TCCU-2 16-TCCU-3 16-TCCU-4 16-TCCU-5 16-TCCU-6 16-TCCU-7 16-TCCU-8 16-TCCU-9 16-TCCU-10 16-TCCU-11 16-TCCU-12 16-TCCU-13 16-TCCU-14 16-TCCU-15 16-TCCU-16 16-TCCU-17 16-TCCU-18 16-TCCU-19 16-TCCU-20 16-TCCU-23 16-TCCU-25 16-TCCU-27 16-TCCU-29 16-TCCU-31 16-TCCU-32 16-TCCU-37

Number of Conductors

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

518 20140902

TFN, THWN or THHN Insulated Conductors Overall Shield, Drain Wire, 600V

CONTROL CABLES

Item #

Number of Conductors

Size AWG

Number of Strands

Overall PVC Jacket (mil)

Nominal Diameter (in)

Weight /MFT (lb)

14-TCCU-2 14-TCCU-3 14-TCCU-4 14-TCCU-5 14-TCCU-6 14-TCCU-7 14-TCCU-8 14-TCCU-9 14-TCCU-10 14-TCCU-11 14-TCCU-12 14-TCCU-13 14-TCCU-14 14-TCCU-15 14-TCCU-16 14-TCCU-17 14-TCCU-18 14-TCCU-19 14-TCCU-20 14-TCCU-23 14-TCCU-25 14-TCCU-27 14-TCCU-29 14-TCCU-31 14-TCCU-32 14-TCCU-37

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 23 25 27 29 31 32 37

14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

45 45 45 45 45 45 45 45 60 60 60 60 60 60 60 60 60 60 60 60 80 80 80 80 80 80

0.34 0.34 0.37 0.41 0.44 0.44 0.48 0.51 0.58 0.58 0.60 0.62 0.64 0.66 0.66 0.70 0.70 0.70 0.73 0.78 0.85 0.88 0.90 0.92 0.94 0.96

71 75 100 115 140 150 170 195 220 240 265 280 295 310 340 355 370 390 415 475 540 570 600 640 660 755

12-TCCU-2 12-TCCU-3 12-TCCU-4 12-TCCU-5 12-TCCU-6 12-TCCU-7 12-TCCU-8 12-TCCU-9 12-TCCU-10 12-TCCU-11 12-TCCU-12 12-TCCU-13 12-TCCU-14

2 3 4 5 6 7 8 9 10 11 12 13 14

12 12 12 12 12 12 12 12 12 12 12 12 12

7 7 7 7 7 7 7 7 7 7 7 7 7

45 45 45 45 45 45 45 45 60 60 60 60 60

0.36 0.36 0.40 0.45 0.50 0.50 0.58 0.62 0.66 0.66 0.68 0.70 0.73

90 105 135 165 195 215 260 300 325 350 375 400 425

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 518 20140902

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

TFN, THWN or THHN Insulated Conductors Overall Shield, Drain Wire, 600V Item #

Size AWG

Number of Strands

Overall PVC Jacket (mil)

Nominal Diameter (in)

Weight /MFT (lb)

12-TCCU-15 12-TCCU-16 12-TCCU-17 12-TCCU-18 12-TCCU-19 12-TCCU-20 12-TCCU-23 12-TCCU-25 12-TCCU-27 12-TCCU-29 12-TCCU-31 12-TCCU-32 12-TCCU-37

15 16 17 18 19 20 23 25 27 29 31 32 37

12 12 12 12 12 12 12 12 12 12 12 12 12

7 7 7 7 7 7 7 7 7 7 7 7 7

60 60 60 60 60 60 60 80 80 80 80 80 80

0.76 0.76 0.79 0.79 0.79 0.89 0.93 0.96 1.00 1.01 1.06 1.08 1.10

455 485 515 545 565 590 690 770 840 910 950 1000 1090

10-TCCU-2 10-TCCU-3 10-TCCU-4 10-TCCU-5 10-TCCU-6 10-TCCU-7 10-TCCU-8 10-TCCU-9 10-TCCU-10 10-TCCU-11 10-TCCU-12 10-TCCU-13 10-TCCU-14 10-TCCU-15 10-TCCU-16 10-TCCU-17 10-TCCU-18 10-TCCU-19 10-TCCU-20 10-TCCU-23 10-TCCU-25 10-TCCU-27 10-TCCU-29 10-TCCU-31 10-TCCU-32 10-TCCU-37

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 23 25 27 29 31 32 37

10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

45 45 45 60 60 60 60 60 60 60 60 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80

0.46 0.46 0.50 0.58 0.63 0.63 0.69 0.73 0.81 0.81 0.82 0.89 0.92 0.95 0.95 1.02 1.02 1.02 1.07 1.12 1.19 1.22 1.23 1.29 1.31 1.36

126 155 200 265 315 345 420 450 500 540 580 680 725 745 810 860 900 940 990 1120 1210 1295 1375 1465 1510 1710

CONTROL CABLES

Number of Conductors

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

518 20140902

CONTROL CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

THWN or THHN Insulated Conductors with Ground PVC Jacket, 600V Applications As flame-retardant three or four conductor power cables rated 600V, 90°C in dry locations. 75°C in wet locations. Specifically approved for installation in cable trays per Article 336 of the NEC. Type TC cable is also approved for use in Class I and II, Division 2 hazardous locations. Cables may be installed in open air, in ducts or conduits, in tray or trough, or direct buried. Construction Individual conductors of stranded uncoated copper Type THWN or THHN, surface print phase identification. Three or four insulated conductors twisted with a Class B stranded uncoated copper grounding conductor and fillers, cable tape, PVC jacket overall, surface printed. Standards • Listed by UL as Type TC Tray Cable per Article 336 of the NEC. • Individual conductors UL listed as Type THWN or THHN. • Overall jacket UL listed as Sunlight Resistant. • Cables UL listed for Direct Burial. • Cables UL listed for Open Wiring. • Cables and color coding pass UL and IEEE-383 ribbon burner tests and ICEA 210.00 BTU/hr test. Notes • Ampacity in accordance with the National Electric Code for cables in uncovered cable tray without maintained space and for cable in raceway or direct buried. 90°C conductor temperature for dry locations, 75°C conductor temperature for wet locations, 30°C ambient temperature. • Grounding conductor per UL Standard 1277 for Type TC Tray Cable.

Item#

Number of Conductors

Size AWG or KCM

Number of Strands

PVC Insulation Thickness (mil)

Nylon Jacket Thickness (mil)

Overall PVC Jacket (mil)

Nominal Diameter (in)

Grounding Conductor Size AWG

Weight /MFT (lb)

3 3 3 3 3 3 3 3 3 3 3 3 3 3

8 6 4 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1000

7 7 7 7 19 19 19 19 19 37 37 37 61 61

30 30 40 40 50 50 50 50 50 60 60 60 70 70

5 5 6 6 7 7 7 7 7 8 8 8 9 9

60 60 80 80 80 80 80 80 80 110 110 110 110 140

0.62 0.70 0.88 1.01 1.14 1.23 1.32 1.42 1.56 1.76 1.98 2.26 2.71 3.10

10 8 8 6 6 6 6 4 4 4 3 2 1 1/0

315 445 675 995 1200 1480 1770 2180 2690 3225 4370 5960 9050 11720

3 Conductor

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

519 20140902

CONTROL CABLES

TC3-8 TC3-6 TC3-4 TC3-2 TC3-1 TC3-1/0 TC3-2/0 TC3-3/0 TC3-4/0 TC3-250 TC3-350 TC3-500 TC3-750 TC3-1000

THWN or THHN with Ground PVC Jacket, 600V Item#

Number of Conductors

Size AWG or KCM

Number of Strands

PVC Insulation Thickness (mil)

Nylon Jacket Thickness (mil)

Overall PVC Jacket (mil)

Nominal Diameter (in)

Grounding Conductor Size AWG

Weight /MFT (lb)

4 4 4 4 4 4 4 4 4 4 4 4 4

8 6 4 2 1 1/0 2/0 3/0 4/0 250 350 500 750

7 7 7 7 19 19 19 19 19 37 37 37 61

30 30 40 40 50 50 50 50 50 60 60 60 70

5 5 6 6 7 7 7 7 7 8 8 8 9

60 60 80 80 80 80 80 80 110 110 110 110 140

0.68 0.76 0.97 1.11 1.26 1.36 1.47 1.58 1.79 1.95 2.20 2.51 3.07

12 10 10 9 9 9 9 7 7 7 6 5 4

405 555 846 1256 1515 1913 2351 2760 3545 4148 5480 7924 11340

4 Conductor

CONTROL CABLES

TC4-8 TC4-6 TC4-4 TC4-2 TC4-1 TC4-1/0 TC4-2/0 TC4-3/0 TC4-4/0 TC4-250 TC4-350 TC4-500 TC4-750

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 519 20140902

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Aluminum Three Conductor UL Type TC 600V Applications These cables are specifically approved for power, control, lighting and signal circuits, in manufacturing, industrial and commercial installations. For use in direct burial, in cable trays, in raceways, or where supported in outdoor locations by a messenger wire. In cable tray in hazardous (classified) locations Class I, Division 2 per NEC, also as Class I circuits per Article 725, and in Class II, Division 2, as permitted per NEC. When installed in accordance with NEC 336.10(7), TC-ER marked cable is approved for use as open wiring between a cable tray and the utilization equipment or device. Construction Assembly consisting of three or four insulated aluminum alloy AA8000 compact stranded conductors, cabled together with a bare equipment grounding conductor and non-hygroscopic fillers. The sub-assembly is wrapped with binding tape and a PVC jacket is applied over the taped assembly. PVC jacket is sunlight resistant, moisture resistant and flame retardant. This cable uses XHHW-2 conductors that are phase identified, including one insulated black conductor, one insulated white conductor, and one insulated conductor with a single longitudinal red stripe. If required, a fourth insulated conductor has a single longitudinal blue stripe. Phase conductors are insulated with crosslinked polyethylene (XLPE) and rated for a maximum operating temperature of 90°C in dry and wet locations, rated for 600 volts maximum operating voltage. Insulation is free of harmful heavy metals in compliance with RoHS, Directive 2002/95/EC. Standards • UL 1277 Type TC Tray Cable • UL 44 Thermoset Insulated Conductors, Type XHHW-2 or RHW-2 • ICE A S-73-5 32 • NEMA WC57 Standard for Control Cables • ICE A S-95-658 Standard for Non-shielded Power Cables Rated 2000 Volts or less Notes Terminates safely with industry standard dual rated terminals and connectors.

Item #

Insulation Thickness (mil)

Jacket Thickness (mil)

Nominal Diameter (in)

Nominal Weight (lb/MFT)

Package Length (ft)

Ampacity 90°C

Ampacity 75°C

45 45 45 55 55 55 55 55 65 65 65 65 65 65 80 80 80 80 80 80

60 60 80 80 80 80 80 80 80 110 110 110 110 110 110 110 110 140 140 140

0.76 0.82 0.95 1.08 1.14 1.22 1.32 1.43 1.57 1.74 1.74 1.83 1.94 2.11 2.34 2.47 2.54 2.80 2.91 3.19

234 293 431 544 629 739 872 1061 1238 1524 1559 1711 1888 2251 2692 3069 3244 4059 4271 5786

1000 1000 1000 1000 1000 1000 1000 1000 500 500 500 500 500 500 500 500 500 500 500 500

75 75 100 115 135 150 175 205 230 260 260 280 305 350 385 425 435 480 480 480

50 65 90 100 120 135 155 180 205 230 230 250 270 310 340 375 385 425 425 425

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

529 20140626

CONTROL CABLES

A6-03XHPGTC-6 A4-03XHPGTC-6 A2-03XHPGTC-6 A1-03XHPGTC-4 A1/0-03XHPGTC-4 A2/0-03XHPGTC-4 A3/0-03XHPGTC-4 A4/0-03XHPGTC-2 A250-03XHPGTC-2 A300-03XHPGTC-2 A300-03XHPGTC-1/0 A350-03XHPGTC-2 A400-03XHPGTC-1 A500-03XHPGTC-1 A600-03XHPGTC-1 A700-03XHPGTC-1/0 A750-03XHPGTC-1/0 A900-03XHPGTC-250 A900-03XHPGTC-400 A900-03XHPGTC-750

Conductor No. of Grounding Size Phase Conductor AWG Conductors AWG or kcmil or kcmil 6 3 6 4 3 6 2 3 6 1 3 4 1/0 3 4 2/0 3 4 3/0 3 4 4/0 3 2 250 3 2 300 3 2 300 3 1/0 350 3 2 400 3 1 500 3 1 600 3 1 700 3 1/0 750 3 1/0 900 3 250 900 3 400 900 3 750

CONTROL CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Aluminum Four Conductor UL Type TC 600V Applications These cables are specifically approved for power, control, lighting and signal circuits, in manufacturing, industrial and commercial installations. For use in direct burial, in cable trays, in raceways, or where supported in outdoor locations by a messenger wire. In cable tray in hazardous (classified) locations Class I, Division 2 per NEC, also as Class I circuits per Article 725, and in Class II, Division 2, as permitted per NEC. When installed in accordance with NEC 336.10(7), TC-ER marked cable is approved for use as open wiring between a cable tray and the utilization equipment or device. Construction Assembly consisting of three or four insulated aluminum alloy AA8000 compact stranded conductors, cabled together with a bare equipment grounding conductor and non-hygroscopic fillers. The sub-assembly is wrapped with binding tape and a PVC jacket is applied over the taped assembly. PVC jacket is sunlight resistant, moisture resistant and flame retardant. This cable uses XHHW-2 conductors that are phase identified, including one insulated black conductor, one insulated white conductor, and one insulated conductor with a single longitudinal red stripe. If required, a fourth insulated conductor has a single longitudinal blue stripe. Phase conductors are insulated with crosslinked polyethylene (XLPE) and rated for a maximum operating temperature of 90°C in dry and wet locations, rated for 600 volts maximum operating voltage. Insulation is free of harmful heavy metals in compliance with RoHS, Directive 2002/95/EC. Standards • UL 1277 Type TC Tray Cable • UL 44 Thermoset Insulated Conductors, Type XHHW-2 or RHW-2 • ICE A S-73-5 32 • NEMA WC57 Standard for Control Cables • ICE A S-95-658 Standard for Non-shielded Power Cables Rated 2000 Volts or less Notes Terminates safely with industry standard dual rated terminals and connectors.

Item #

Insulation Thickness (mil)

Jacket Thickness (mil)

Nominal Diameter (in)

Nominal Weight (lb/MFT)

Package Length (ft)

Ampacity 90°C

Ampacity 75°C

45 45 45 55 55 55 55 55 65 65 65 65 65 80 80 80 80 80 80 80 80

80 80 80 80 80 80 80 80 110 110 110 110 110 110 140 140 140 140 140 140 140

0.87 0.95 1.06 1.21 1.28 1.36 1.46 1.61 1.83 1.93 2.05 2.15 2.34 2.59 2.80 2.88 3.34 3.10 3.13 3.28 3.53

315 400 526 683 797 928 1097 1346 1704 1948 2217 2416 2906 3477 4094 4363 5234 5067 5163 5405 5919

1000 1000 1000 1000 1000 1000 1000 1000 500 500 500 500 500 500 500 500 500 500 500 500 500

55 75 100 115 135 150 175 205 230 260 280 305 350 385 425 435 435 480 480 480 480

50 65 90 100 120 135 155 180 205 230 250 270 310 340 375 385 385 425 425 425 425

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

530 20140626

CONTROL CABLES

A6-04XHPGTC-6 A4-04XHPGTC-6 A2-04XHPGTC-6 A1-04XHPGTC-4 A1/0-04XHPGTC-4 A2/0-04XHPGTC-4 A3/0-04XHPGTC-4 A4/0-04XHPGTC-2 A250-04XHPGTC-1 A300-04XHPGTC-1 A350-04XHPGTC-1/0 A400-04XHPGTC-1/0 A500-04XHPGTC-2/0 A600-04XHPGTC-2/0 A700-04XHPGTC-2/0 A750-04XHPGTC-3/0 A750-04XHPGTC-750 A900-04XHPGTC-4/0 A900-04XHPGTC-250 A900-04XHPGTC-400 A900-04XHPGTC-750

Conductor No. of Grounding Size Phase Conductor AWG Conductors AWG or kcmil or kcmil 6 4 6 4 4 6 2 4 6 1 4 4 1/0 4 4 2/0 4 4 3/0 4 4 4/0 4 2 250 4 1 300 4 1 350 4 1/0 400 4 1/0 500 4 2/0 600 4 2/0 700 4 2/0 750 4 3/0 750 4 750 900 4 4/0 900 4 250 900 4 400 900 4 750

CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Thermocouple Cable EX, JX, KX, TX 600V Application For use as a 600V, multi-pair thermocouple instrumentation cable where flame-retardance, and moisture/chemical resistance is critical. Cable can be installed in free air, in raceways, or direct burial. The cable is also approved for wet or dry locations as well as Class 1 Division II industrial hazardous locations per NEC 501-4(b) for (UL) Type Tray Cables (TC). Temperature rating of 90°C wet or dry. Insulation provides excellent electrical, thermal, and physical properties, excellent flame resistance and resistant to crush, compression, cuts and heat deformation. Also conductor insulation provides good low temperature (-40°C) cold bend characteristics. Approved for direct burial. Construction • Conductor is thermocouple alloy per ANSI MC96.1 — 1982. • Flame-retardant XLPE insulation. • Conductors twisted together with a drain wire and aluminum mylar shield. Shielded pairs cabled together with fillers as needed to form a round core. An overall aluminum mylar shield and drain wire is applied over the core. • Pairs are color coded per thermocouple type with pair number printed on the negative (red) conductor. See chart below for specific color codes. • Black, flame-retardant, sunlight resistant, Chlorinated Polyethylene (CPE) jacket. Available with color coded jacket. • Available with class B stranding per ASTM B174. Standards • Insulated Conductor — VW-1 • UL Type TC, 90°C Wet or Dry, 600V • ICEA S-82-552, 90°C Wet or Dry, 600V. • Passes UL 1277 Flame Test (70,000 BTU/hr). • Passes UL 1202 Flame Test (70,000 BTU/hr). • Passes IEEE 383 Flame Test (70,000 BTU/hr). • Passes ICEA T-29-520 Flame Test (210,000 BTU/hr) EX Color Code • Chromel (Positive) — PURPLE • Constantan (Negative) — RED JX Color Code • Iron (Positive) — WHITE • Constantan (Negative) — RED TX Color Code • Copper (Positive) — BLUE • Constantan (Negative) — RED

Notes Dimensions and weights shown are nominal, subject to industry tolerances. Dimensions and weights for other cable configurations are available upon request. Options • PVC Insulation, EPR Insulation • PVC Jacket • 300V • Overall shield, shielded pairs overall shield

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

520 20140110

CONTROL CABLES

KX Color Code • Chromel (Positive) — YELLOW • Alumel (Negative) — RED

Thermocouple Cable EX, JX, KX, TX 600V Size AWG

Number of Shielded Pairs

Insulation Thickness (in)

Jacket Thickness (in)

Overall Diameter (in)

Weight /MFT (lb)

ITC-20-1 ITC-20-2 ITC-20-3 ITC-20-4 ITC-20-6 ITC-20-8 ITC-20-10 ITC-20-12 ITC-20-16 ITC-20-24

20 20 20 20 20 20 20 20 20 20

1 2 3 4 6 8 10 12 16 24

0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025

0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045

0.270 0.035 0.450 0.500 0.600 0.670 0.735 0.790 0.890 1.060

35 70 85 105 160 210 240 280 360 500

ITC-18-1 ITC-18-2 ITC-18-3 ITC-18-4 ITC-18-6 ITC-18-8 ITC-18-10 ITC-18-12 ITC-18-16 ITC-18-24

18 18 18 18 18 18 18 18 18 18

1 2 3 4 6 8 10 12 16 24

0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025

0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045

0.300 0.480 0.510 0.595 0.670 0.750 0.820 0.930 1.045 1.235

50 90 115 165 220 280 340 430 540 760

ITC-16-1 ITC-16-2 ITC-16-3 ITC-16-4 ITC-16-6 ITC-16-8 ITC-16-10 ITC-16-12 ITC-16-16 ITC-16-24

16 16 16 16 16 16 16 16 16 16

1 2 3 4 6 8 10 12 16 24

0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025 0.025

0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045

0.325 0.570 0.600 0.660 0.740 0.880 0.970 1.035 1.165 1.400

60 130 160 200 270 380 460 530 570 960

CONTROL CABLES

Item #

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 520 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

IMSA 19-1 & 20-1 Traffic Control Cable 600V Application For use in signal systems in underground conduit/duct, or as aerial cable supported by a messenger, or for installation in buildings. Construction • Solid Conductor or Stranded Conductor • Polyethylene Insulation, 75°C, 600V • 19-1: Black PVC Jacket • 20-1: Black PE Jacket

Item #

No. of Conductors

Insulation Thickness (in)

Jacket Wall Solid (in)

Jacket Wall Stranded (in)

O.D. Solid Solid (in)

O.D. Solid Stranded (in)

Total Weight Solid/MFT (lb)

Total Weight Stranded/MFT (lb)

IMSA 19-1 IMSA-19-1-14-2 IMSA-19-1-14-3 IMSA-19-1-14-4 IMSA-19-1-14-5 IMSA-19-1-14-7 IMSA-19-1-14-9 IMSA-19-1-14-10 IMSA-19-1-14-12 IMSA-19-1-14-16 IMSA-19-1-14-19 IMSA-19-1-14-20 IMSA-19-1-14-24 IMSA-19-1-14-30 IMSA-19-1-14-37

14 14 14 14 14 14 14 14 14 14 14 14 14 14

2 3 4 5 7 9 10 12 16 19 20 24 30 37

.025 .025 .025 .025 .025 .025 .025 .025 .025 .025 .025 .025 .025 .025

0.045 0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.060 0.060 0.080 0.080

0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.060 0.060 0.080 0.080 0.080

0.329 0.346 0.377 0.410 0.445 0.517 0.591 0.608 0.672 0.707 0.743 0.823 0.911 0.979

0.347 0.366 0.398 0.435 0.472 0.580 0.627 0.606 0.715 0.752 0.791 0.917 0.968 1.042

62 74 93 114 146 188 221 255 328 377 398 470 605 727

67 79 99 122 156 216 235 272 350 402 424 535 644 774

IMSA-19-1-12-2 IMSA-19-1-12-3 IMSA-19-1-12-4 IMSA-19-1-12-5 IMSA-19-1-12-7 IMSA-19-1-12-9 IMSA-19-1-12-10 IMSA-19-1-12-12 IMSA-19-1-12-16 IMSA-19-1-12-19 IMSA-19-1-12-20 IMSA-19-1-12-24 IMSA-19-1-12-30 IMSA-19-1-12-37

12 12 12 12 12 12 12 12 12 12 12 12 12 12

2 3 4 5 7 9 10 12 16 19 20 24 30 37

.030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .030

0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.060 0.080 0.080 0.080 0.080 0.080

0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.080 0.080 0.080 0.080 0.080 0.080

0.383 0.404 0.442 0.483 0.556 0.645 0.699 0.720 0.799 0.882 0.926 1.025 1.084 1.168

0.405 0.428 0.468 0.513 0.589 0.684 0.743 0.766 0.891 0.937 0.985 1.091 1.154 1.245

89 107 135 168 232 297 324 377 490 598 630 745 904 1091

95 113 143 178 246 315 343 399 552 633 667 789 956 1155

CONTROL CABLES

Size AWG

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

521 20140110

IMSA 19-1 & 20-1 Traffic Control Cable 600V Size AWG

No. of Conductors

Insulation Thickness (in)

Jacket Wall Solid (in)

Jacket Wall Stranded (in)

O.D. Solid Solid (in)

O.D. Solid Stranded (in)

Total Weight Solid/MFT (lb)

Total Weight Stranded/MFT (lb)

IMSA 20-1 IMSA-20-1-14-2 IMSA-20-1-14-3 IMSA-20-1-14-4 IMSA-20-1-14-5 IMSA-20-1-14-7 IMSA-20-1-14-9 IMSA-20-1-14-10 IMSA-20-1-14-12 IMSA-20-1-14-16 IMSA-20-1-14-19 IMSA-20-1-14-20 IMSA-20-1-14-24 IMSA-20-1-14-30 IMSA-20-1-14-37

14 14 14 14 14 14 14 14 14 14 14 14 14 14

2 3 4 5 7 9 10 12 16 19 20 24 30 37

.025 .025 .025 .025 .025 .025 .025 .025 .025 .025 .025 .025 .025 .025

0.045 0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.060 0.060 0.080 0.080

0.045 0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.060 0.060 0.080 0.080 0.080

0.329 0.346 0.377 0.410 0.445 0.517 0.591 0.608 0.672 0.707 0.743 0.823 0.911 0.979

0.347 0.366 0.398 0.435 0.472 0.580 0.627 0.606 0.715 0.752 0.791 0.917 0.968 1.042

54 66 83 104 135 174 201 234 305 353 372 441 563 681

58 70 89 111 144 196 214 243 325 376 396 493 600 726

IMSA-20-1-12-2 IMSA-20-1-12-3 IMSA-20-1-12-4 IMSA-20-1-12-5 IMSA-20-1-12-7 IMSA-20-1-12-9 IMSA-20-1-12-10 IMSA-20-1-12-12 IMSA-20-1-12-16 IMSA-20-1-12-19 IMSA-20-1-12-20 IMSA-20-1-12-24 IMSA-20-1-12-30 IMSA-20-1-12-37

12 12 12 12 12 12 12 12 12 12 12 12 12 12

2 3 4 5 7 9 10 12 16 19 20 24 30 37

.030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .030 .030

0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.060 0.080 0.080 0.080 0.080 0.080

0.045 0.045 0.045 0.045 0.060 0.060 0.060 0.060 0.080 0.080 0.080 0.080 0.080 0.080

0.383 0.404 0.442 0.483 0.556 0.645 0.699 0.720 0.799 0.882 0.926 1.025 1.084 1.168

0.405 0.428 0.468 0.513 0.589 0.684 0.743 0.766 0.891 0.937 0.985 1.091 1.154 1.245

79 96 123 155 214 275 300 351 462 558 587 697 853 1036

84 102 131 165 226 291 317 372 511 590 622 738 902 1097

CONTROL CABLES

Item #

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 521 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

IMSA 19-1 & 20-1 Traffic Control Cable Shipping Weights AWG/ Conductors

IMSA 19-1 Solid Weight /MFT (lb)

IMSA 19-1 Stranded Weight /MFT (lb)

IMSA 20-1 Solid Weight /MFT (lb)

IMSA 20-1 Stranded Weight /MFT (lb)

16/2 16/3 16/4 16/5 16/7 16/9 16/10 16/12

16/2 16/3 16/4 16/5 16/7 16/9 16/10 16/12

— — — — — — — —

29 44 58 73 102 131 146 175

— — — — — — — —

21 34 48 63 89 111 124 152

14/2 14/3 14/4 14/5 14/7 14/9 14/10 14/12 14/14 14/15 14/16 14/19 14/20 14/21 14/25 14/26

14/2 14/3 14/4 14/5 14/7 14/9 14/10 14/12 14/14 14/15 14/16 14/19 14/20 14/21 14/25 14/26

58 75 94 113 146 186 220 254 — 311 325 375 395 462 478 497

63 81 98 118 154 212 227 267 312 328 341 393 415 432 544 566

52 66 85 103 136 172 197 232 — 284 299 348 370 384 450 468

55 71 88 108 141 162 205 244 285 302 316 366 387 405 498 518

12/2 12/3 12/4 12/5 12/7 12/9 12/10 12/12 12/16 12/19 12/20 12/21 12/25

12/2 12/3 12/4 12/5 12/7 12/9 12/10 12/12 12/16 12/19 12/20 12/21 12/25

82 108 135 163 237 281 312 372 449 599 631 663 789

87 113 141 172 244 310 338 393 541 625 658 691 822

74 99 124 152 212 273 296 346 461 547 576 605 720

77 103 130 159 222 284 309 367 501 582 618 643 751

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

521 20140110

CONTROL CABLES

Item #

CONTROL CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

IMSA 50-2 Loop Detector Lead-In Wire 600V Application Used in municipal signal systems as lead-in cable or for use in communication circuits where a low capacitance is needed, suitable for underground conduit, as aerial cable supported by messenger, or in raceways in buildings. Construction • Unilay stranded tin coated, annealed copper per ASTM-B-33 • Twisted pair with overall shield and drain wire • Insulation is high molecular weight PE per UL 758, black and clear • Aluminum/Polyester tape shield helically applied • Polyetheylene Jacket, black Standards IMSA Spec No. 50-2-1984. Also available: NCDOT 1993 and NCDOT 06-031110.

Item #

IMSA-50-2-18 IMSA-50-2-16 IMSA-50-2-14 IMSA-50-2-12

Size AWG

Stranding

Nominal Jacket Thickness (in)

Nominal O.D. (in)

Nominal Weight /MFT (lb)

18 16 14 12

19 19 19 19

.032 .032 .032 .032

.284 .306 .338 .376

31 39 54 75

CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

522 20140110

CONTROL CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

IMSA 51-1 THHN Loop Detector Lead-In Wire 600V Application Designed for use in municipal signal systems as “Loop Detector Wire.” These wires are installed in pavement saw cuts at traffic intersections to detect the presence of motor vehicles. The signal is sent to a traffic signal controller to activate the light changes. Construction Conductors: Stranded, uncoated annealed copper per ASTM B-8. Other strandings and tinned conductors available upon special request. Insulation: Heat stabilized PVC with a nylon jacket per IMSA Specification No. 51.1 paragraph 4 and 6. Insulation color is black. Standards Dimensionals physicals and electricals per IMSA SPECIFICATION NO. 51.1

Item #

IMSA-51-1-18 IMSA-51-1-16 IMSA-51-1-14 IMSA-51-1-12 IMSA-51-1-10

Size AWG

Number of Strands

Strands O.D. (in)

Insulation Thickness (in)

Jacket Wall (in)

Overall Diameter (in)

Weight /MFT (lb)

18 16 14 12 10

7 7 7 7 7

.0152 .0192 .0242 .0305 .0385

.015 .015 .015 .015 .015

.004 .004 .004 .004 .004

.085 .097 .112 .131 .165

7 11 16 24 38

CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

523 20140110

CONTROL CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

IMSA 51-3 Loop Detector Wire 600V Application Designed for use in municipal signal systems as "Loop Detector Wire". These wires are installed in pavement saw cuts at traffic intersections to detect the presence of motor vehicles. The signal is sent to a traffic signal controller to activate the light changes. Construction Conductors: Solid or stranded, bare, uncoated copper with separator per ASTM B03 or B08. Other strandings and tinned conductors available upon special request. Insulation: Cross-linked polyethylene per IMSA Specification No. 51-3, paragraph 4. Insulation color is black. Standards Tests: Dimensionals, physicals, and electricals per IMSA Specification No. 51-3. Note The data listed is approximate and subject to normal manufacturing tolerances. Alternate constructions or materials may be available.

Item #

Size AWG

Number of Strands

Strands O.D. (in)

Insulation Thickness (in)

Overall Diameter (in)

Weight /MFT (lb)

14 14 14 12 12 10 10 8 6 4 2

Solid 7 19 Solid 7 Solid 7 7 7 7 7

N/A .0242 .0147 N/A .0305 N/A .0385 .0486 .0612 .0772 .0974

.030 .0.0 .030 .030 .030 .030 .030 .045 .045 .045 .045

.125 .135 .135 .145 .155 .165 .180 .240 .275 .325 .380

17 18 18 25 26 38 39 66 99 151 232

IMSA-51-3-14-S IMSA-51-3-14-7 IMSA-51-3-14-19 IMSA-51-3-12-S IMSA-51-3-12-7 IMSA-51-3-10-S IMSA-51-3-107 IMSA-51-3-87 IMSA-51-3-67 IMSA-51-3-47 IMSA-51-3-27 Shipping Weights Item #

IMSA Spec No.

14 12

51-3 51-3

Description Insulation Type

Weight /MFT (lb)

Tinned Copper STR XLPE Insulation Tinned Copper STR XLPE Insulation

17 29

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

524 20140110

CONTROL CABLES

51-3-14 51-3-12

Size AWG

CONTROL CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

IMSA 51-5 Inductant Loop Detector Cable 600V Application Used in road pavements to detect vehicles for the purpose of changing signals or determining amount of traffic flow. Construction • Single conductor, 600V • PVC/Nylon Insulation in PVC or PE tube jacket, 75°C • AWG #14 (2.08mm) one copper conductor per ASTM B-3) • 19 strand concentric or bunch stranding • 15 mils of black PVC per UL 62 • Jacket is clear nylon per ASTM D-4066 • Encasing tube is PVC or HDPE compound • Temperature rating: 60°C • Voltage rating: 600V Specifications IMSA Spec No. 51-5-1984. Also available: NCDOT 199 and NCDOT 06-24273. Option • XLPE Insulation

Item #

IMSA-51-5-14 IMSA-51-5-12 Shipping Weights Item #

Number of Strands

O.D. Outside Diameter (in)

O.D. Inside Diameter (in)

O.D. Wall Thickness (in)

PVC Total Weight /MFT (lb)

PE Total Weight /MFT (lb)

14 12

19 19

.250 .260

.190 .200

.030 .030

30.00 38.00

25.00 34.00

Size AWG

IMSA Spec No.

Description Insulation Type

Encasing Tube

Weight /MFT (lb)

14 12 14 12 14 12 14 12

51-5 51-5 51-5 51-5 51-5 51-5 51-5 51-5

Bare CU STR XLPE Insulation Bare CU STR XLPE Insulation Bare CU STR XLPE Insulation Bare CU STR XLPE Insulation Bare CU STR PVC/Nylon Insulation Bare CU STR PVC/Nylon Insulation Bare CU STR PVC/Nylon Insulation Bare CU STR PVC/Nylon Insulation

PVC PVC HDPE HDPE PVC PVC HDPE HDPE

31 41 33 43 27 36 29 39

CONTROL CABLES

51-5 XLPE/PVC 14 51-5 XLPE/PVC 12 51-5 XLPE/HDPE 14 51-5 XLPE/HDPE 12 51-5 PVC/PVC 14 51-5 PVC/PVC 12 51-5 PVC/HDPE 14 51-5 PVC/HDPE 12

Size AWG

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

525 20140110

CONTROL CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

IMSA Cable Selection Guide Item #

IMSA Spec No.

Voltage Rating

Applications

Installation

Conductor Configuration

Mechanical Characteristics

19-1

19-1

600

Aerial or Duct

19-2

600

Cabled Conductors Twisted Pairs

PVC Outer Jacket

19-2 19-3

19-3

600

19-4

19-4

600

19-5

19-5

600

Traffic Signal Fire Protective Signal Traffic Signal Fire Protective Signal Traffic Signal Fire Protective Signal Traffic Signal Fire Protective Signal Traffic Signal Fire Protective Signal

16-6

19-6

600

Traffic Signal Fire Protective Signal

20-1

20-1

600

20-2

20-2

600

20-3

20-3

600

20-4

20-4

600

20-5

20-5

600

20-6

20-6

600

26-3

26-3



Traffic Signal Aerial or Duct Fire Protective Signal Traffic Signal, Aerial or Duct Fire Protective Signal Traffic Signal Figure-8 Aerial Fire Protective Signal Integral Msgr. Traffic Signal Figure-8 Aerial Fire Protective Signal Integral Msgr. Traffic Signal Aerial, Duct or Buried Fire Protective Signal Traffic Signal Aerial, Duct or Buried Fire Protective Signal Signal Systems Aerial Self-Supporting Copper Conductor

28-3

28-3



29-1

29-1



29-2

29-2



29-3

29-3



29-4

29-4



39-2

39-2

300

Signal Systems

Aerial or Duct Figure-8 Aerial Integral Msgr. Figure-8 Aerial Integral Msgr. Aerial, Duct or Buried

Cabled Conductors Twisted Pairs Cabled Conductors

Aerial, Duct or Buried

Twisted Pairs

Cabled Conductors Twisted Pairs Cabled Conductors Twisted Pairs Cabled Conductors Twisted Pairs Single Hard-Drawn

Shielded PVC Outer Jacket Shielded PE Inner & PVC Outer Jackets Shielded, PE Inner & PVC Outer Jackets PE Outer Jacket Shielded PE Outer Jacket PE Outer Jacket Shielded PE Outer Jacket Shielded, PE Inner & Outer Jacket Shielded, PE Inner & Outer Jacket High Density Polyethylene (HDPE)Insulation HDPE Insulation HDPE Insulation

HDPE Insulation

HDPE Insulation PVC Outer Jacket HDPE Insulation PVC Outer Jacket Shielded PVC Outer Jacket

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

526 20140110

CONTROL CABLES

Aerial Self-Supporting Single Copper-Covered Steel Conductor Signal Systems Aerial Self-Supporting C Line Wire (Parallel) 2 Hard-Drawn Copper Conductors Signal Systems Aerial Self-Supporting C Line Wire (Parallel 2 Copper-Covered Steel Conductors Signal Systems Aerial Self-Supporting C Line Wire (Parallel) 2 Hard-Drawn Copper Conductors Signal Systems Aerial Self-Supporting C Line Wire (Parallel) 2 Copper-Covered Steel Conductors Fire Protective Signal Aerial, Duct or Twisted Pairs Traffic Communications Building Raceway Data Acquisition

Shielded PVC Outer Jacket PVC Outer Jacket

CONTROL CABLES

IMSA Cable Selection Guide Item #

IMSA Spec No.

Voltage Rating

39-4

39-4

300

39-6

39-6

300

40-2

40-2

300

40-4

40-4

300

40-6

40-6

300

50-2

50-2

600

51-1

51-1

51-3

Applications

Installation

Conductor Configuration

Mechanical Characteristics

Twisted Pairs

Shielded PVC Outer Jacket Shielded PE Inner & PVC Outer Jackets Shielded PE Outer Jacket

600

Traffic Communications Figure-8 Aerial Data Acquisition Integral Msgr. Fire Protective Signal Aerial, Duct or Traffic Communications Building Raceway Data Acquisition Fire Protective Signal Aerial, Duct or Traffic Communications Building Raceway Data Acquisition Traffic Communications Figure-8 Aerial Data Acquisition Integral Msgr. Fire Protective Signal Aerial, Duct, Buried or Traffic Communications Building Raceway Data Acquisition Signal Loop Detector Duct or Buried Lead-In Feeder Inductance Loop Detector Duct

Single Conductor

51-3

600

Inductance Loop Detector

Duct or Buried

Single Conductor

51-5

51-5

600

Inductance Loop Detector

Duct or Buried

Single Conductor

51-7

51-7

600

Inductance Loop Detector

Duct or Buried

Single Conductor

59-2

59-2

300

Aerial or Duct

Twisted Pairs

59-4

59-4

300

Fire Protective Signal Traffic Communications Data Acquisition Traffic Communications Data Acquisition

Figure-8 Aerial Integral Msgr.

Twisted Pairs

59-6

59-6

300

Fire Protective Signal Traffic Communications Data Acquisition

Aerial, Duct or Buried

Twisted Pairs

60-2

60-2

300

Aerial or Duct

Twisted Pairs

60-4

60-4

300

Fire Protective Signal Traffic Communications Data Acquisition Traffic Communications Data Acquisition

Figure-8 Aeria Integral Msgr.

Twisted Pairs

60-6

60-6

300

Fire Protective Signal Traffic Communications Data Acquisition

Aerial, Duct or Buried

Twisted Pairs

70-1

70-1



Traffic Communications

2 to 72 fibers

70-5

70-5



Traffic Communications

Aerial, Duct or Buried Duct or Buried

Shielded PE Outer Jacket Shielded PE Inner & Outer Jacket PE Insulation PE Outer Jacket PVC/Nylon Insulation Cross-Linked PE Insulation PVC/Nylon Insulation in PVC or PE Tube Cross-Linked PE Insulation in PVC or PE Tube Filled Core, Shielded PVC Outer Jacket Filled Core, Shielded PVC Outer Jacket Filled Core Shielded PE Inner Jacket PVC Outer Jacket Filled Core Shielded PE Outer Jacket Filled Core Shielded PE Outer Jacket Filled Core, Shielded, PE Inner and PE Outer Jacket All Dialectric

2 to 72 fibers

Armored

Twisted Pairs

Twisted Pairs

Twisted Pairs Twisted Pairs

Twisted Pairs

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 526 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

IMSA Cable Color Code Chart Method 1 This color code system employs six (6) different base colors alternating through a series of 21 conductors. In this series, the last 15 conductors are marked with tracers of contrasting colors. The color sequence is repeated in regular sequence as necessary for cable configurations employing more than twenty-one (21) conductors.

Item # IMSA-CC-1 IMSA-CC-2 IMSA-CC-3 IMSA-CC-4 IMSA-CC-5 IMSA-CC-6 IMSA-CC-7 IMSA-CC-8 IMSA-CC-9 IMSA-CC-10 IMSA-CC-11

Conductor Number

Base Color

Tracer Color

Item #

1 2 3 4 5 6 7 8 9 10 11

Black White Red Green Orange Blue White Red Green Orange Blue

N/A N/A N/A N/A N/A N/A Black Black Black Black Black

IMSA-CC-12 IMSA-CC-13 IMSA-CC-14 IMSA-CC-15 IMSA-CC-16 IMSA-CC-17 IMSA-CC-18 IMSA-CC-19 IMSA-CC-20 IMSA-CC-21

Conductor Number

Base Color

Tracer Color

12 13 14 15 16 17 18 19 20 21

Black Red Green Blue Black White Orange Blue Red Orange

White White White White Red Red Red Red Green Green

CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

527 20140110

CONTROL CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

IMSA Cable XHHX-2 & USE-2 Shipping Weights XHHX-2 Shipping Weights Item #

IMSA-X14 IMSA-X12 IMSA-X10 IMSA-X8 IMSA-X6 IMSA-X4 IMSA-X2 IMSA-X1

Size AWG

14 12 10 8 6 4 2 1

Weight /MFT (lb) 18 25 40 67 100 150 230 290

USE-2 Shipping Weights Item #

IMSA-U14 IMSA-U12 IMSA-U10 IMSA-U8 IMSA-U6 IMSA-U4 IMSA-U2 IMSA-U1

Size AWG

14 12 10 8 6 4 2 1

Weight /MFT (lb) 23 30 43 72 106 157 237 304

CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

528 20140110

CONTROL CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Wire & Cable Methods of Color Coding Used to identify conductors for point-to-point wiring and for circuit diagrams. Color codes are used to establish a standard for use by different manufacturers. The first color code used colored tracers in a solid colored braid. Most control cable color codes are adaptations of this method. Later, for ease and convenience, ink printed versions were developed. Telephone requirements established special color codes. Color Codes (ICEA Methods) ICEA/NEMA Method 1 Colored insulation with contrasting ink tracers as required. Six different insulation colors and four different colored ink tracers are used to provide positive identification through 21 conductors. The same identification sequence is repeated for cables containing more than 21 conductors. ICEA/NEMA Method 2 A neutral colored compound is used with single or double spiral ink tracers as required to provide positive identification through 21 conductors. The identification sequence is repeated for cables containing more than 21 conductors. ICEA/NEMA Method 3 A neutral or single colored insulation compound is surface ink printed with both conductor number and color designation to provide positive identification through 21 conductors. The identification sequence is repeated for colors containing more than 21 conductors. ICEA/NEMA Method 4 A neutral or single colored insulation compound is surface ink printed with conductor number to provide positive conductor identification through 21 conductors. The identification sequence is repeated for cables containing more than 21 conductors.

ICEA/NEMA Method 5 A color coding using braids. Also sometimes specified using colored insulation and contrasting tracers as an extension of Method I to eliminate duplicate conductors. Up to 127 positive conductor coding are available with this method. Usually specified as per: ICEA5-61-402 Table 5-1 or ICEA 5-19-81 Table 5-2. ICEA/NEMA Method 6 A color coding whereby one conductor in each layer is identified by a braid, tape, ridge, stripe or color. ICEA/NEMA Paired Color Code A coding whereby one leg of all pairs is coded white and its mate is coded in accordance with the first 21 conductors of Method 1, omitting white and repeating the sequence as necessary. Telephone Paired Color Code Five colors are paired with each of five mate colors to give 25 identified pairs. The color sequences are repeated for more than 25 pairs using colored binder strings for group identification.

Note: UL and the NEC restrict the use of green and white as colors and stripes. Special color codes are available to meet these requirements. One method is ICEA Method E-2 which is similar to Method 1 and ICEA Method E-4 which is similar to Method 2.

CONTROL CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

B 20140110

Wire & Cable Color Coding Charts ICEA Method 1, Table E-1

ICEA Method 1, Table E-2

(Colored compound with tracers)

(Colored compound with tracers)

Conductor Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

Background or Base Color Black White Red Green Orange Blue White Red Green Orange Blue Black Red Green Blue Black White Orange Blue Red Orange

Tracer Color – – – – – – Black Black Black Black Black White White White White Red Red Red Red Green Green

CONTROL CABLES

*This conductor is in the inside of the assembly.

ICEA Method 2, Table E-1 (Neutral colored compound with tracers)

Conductor Number

1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

First Tracer Color (Wide Tracer) Black White Red Green Orange Blue White Red Green Orange Blue Black Red Green Blue Black White Orange Blue Red Orange

Second Tracer Color (Narrow Tracer) – – – – – – Black Black Black Black Black White White White White Red Red Red Red Green Green

*This conductor is in the inside of the assembly.

Conductor Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

Background or Base Color Black Red Blue Orange Yellow Brown Red Blue Orange Yellow Brown Black Blue Orange Yellow Brown Black Red Orange Yellow Brown Black Red Blue Yellow Brown Black Red Blue Orange Brown Black Red Blue Orange Yellow

Tracer Color – – – – – – Black Black Black Black Black Red Red Red Red Red Blue Blue Blue Blue Blue Orange Orange Orange Orange Orange Yellow Yellow Yellow Yellow Yellow Brown Brown Brown Brown Brown

*This conductor is in the inside of the assembly.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] B 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Wire & Cable Color Coding Charts ICEA Method 1, Table E-2

ICEA Method 3

ICEA Method 4

(Neutral colored compound with tracers)

(Neutral or single color compound with surface printing of numbers and color designations)

(Neutral or single color compound with surface printing of numbers)

Conductor Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

Conductor Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

Background or Base Color Black Red Blue Orange Yellow Brown Red Blue Orange Yellow Brown Black Blue Orange Yellow Brown Black Red Orange Yellow Brown Black Red Blue Yellow Brown Black Red Blue Orange Brown Black Red Blue Orange Yellow

Tracer Color Black Black Black Black Black Red Red Red Red Red Blue Blue Blue Blue Blue Orange Orange Orange Orange Orange Yellow Yellow Yellow Yellow Yellow Brown Brown Brown Brown Brown

Printed Legend 1 – Black 2 – White 3 – Red 4 – Green 5 – Orange 6 – Blue 7 – White–Black 8 – Red–Black 9 – Green–Black 10 – Orange–Black 11 – Blue–Black 12 – Black–White 13 – Red–White 14 – Green–White 15 – Blue–White 16 – Black–Red 17 – White–Red 18 – Orange–Red 19 – Blue–Red 20 – Red–Green 21 – Orange–Green

*This conductor is in the inside of the assembly.

Printed Legend 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

*This conductor is in the inside of the assembly.

CONTROL CABLES

Conductor Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

*This conductor is in the inside of the assembly.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

B 20140110

Wire & Cable Color Coding Charts ICEA Method 5 (Colored compounds with tracers)

CONTROL CABLES

Cond. Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43

Background or Base Color Black White Red Green Orange Blue White Red Green Orange Blue Black Red Green Blue Black White Orange Blue Red Orange Black White Orange Blue Red Orange Black White Red Green Orange Blue Black White Orange White Black White Red Green Orange Blue

First Tracer Color – – – – – – Black Black Black Black Black White White White White Red Red Red Red Green Green White Black Black Black Black Black Red Red Black Black Black White White Red White Red White Black White White Red Red

Second Tracer Color – – – – – – – – – – – – – – – – – – – – Red Red White White White White Green Green Green Orange Green Orange Orange Orange Blue Blue Green Green Green Blue Green Green

Cond. Number 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86

Background or Base Color Black White Red Green Orange Blue Black White Red Green Orange Blue Black White Red Green Orange Blue Black White Red Green Orange Blue Black White Red Green Orange Blue Black Red Green Orange Blue Red Green Blue Orange Green Black White Blue

First Tracer Color White Black White Orange Red Red Orange Black Orange Red Black Black Orange Orange Orange Black Green Green Red Orange Black Orange White White Green Green Green White Red Red Orange Orange Red White White White White Black White Red Green Green Green

Second Tracer Color Blue Blue Blue Red Blue Orange Red Orange Black Blue Blue Orange Green Green Green Blue Blue Orange Blue Blue Blue Blue Red Red Blue Blue Blue Red Black Black Blue Blue Black Green Green Orange Orange Green – – – – –

Cond. Number 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127

Background or Base Color Black White Red Green Blue Black White Red Green Orange Yellow Yellow Yellow Yellow Yellow Yellow Yellow Black White Red Green Orange Blue Black White Green Orange Blue Black Red Green Orange Blue Black White Red Orange Blue Black White Red

First Tracer Color Orange Orange Orange Orange Orange Blue Blue Blue Blue Blue – Black White Red Green Orange Blue Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow

Second Tracer Color – – – – – – – – – – – – – – – – – – – – – – – Red Red Red Red Red White White White White White Green Green Green Green Green Blue Blue Blue

*This conductor is in the inside of the assembly.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] B 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

FIBER OPTIC CABLES Table of Contents OPGW Optical Ground Wire..................................................................................................607 Installation Manual for OPGW Cable ...................................................................................608 OPGW Cable & System Information Guide for Hardware Selection .................................602 ADSS Fiber Optic Cable ........................................................................................................603 Loose Tube Fiber Optic Cable................................................................................................604 Loose Tube Fiber Optic Cable for Direct Burial....................................................................606 HDPE Conduit.........................................................................................................................605 High Density Polyethylene Duct ...........................................................................................609

FIBER OPTIC CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

600 20170321

FIBER OPTIC CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

OPGW Optical Ground Wire Applications OPGW cable is suited for installation on transmission lines with the double function of a ground wire (designed to replace traditional static or shield wires) and a communication wire. OPGW conducts short circuit current and provide lightning resistance as it “shields” conductors, while providing a telecommunications path for internal as well as third party communications. OPGW must be capable of withstanding the mechanical and environmental stresses inflicted on overhead cables (such those caused by wind or ice). OPGW must also be capable of handling electrical faults on the transmission line by providing a path to ground yet preventing damage to the delicate optical fibers inside the cable. OPGW (Optical Ground Wire) with a stainless steel central tube is preferred for its compact size and ability to house up to 72 fibers in a diameter starting at only 12mm. Its small profile offers an exceptional solution to the diameter and weight concerns on many of today’s overloaded transmission towers where an existing shield wire needs to be replaced with an OPGW cable. Construction OPGW cable has two constructions: Central loose tube type:The fibers are placed loosely in a sealed and water resistant central, aluminum tube filled with water blocking gel. This tube provides protection to the fiber during installation and operation under severe environmental conditions. The stainless steel tube may also be aluminum-clad steel depending on the engineering requirements. The stainless optical tube is located at the center of the cable protected by single or multiple layers of aluminum clad steel, aluminum alloy wires, or steel wires. The metallic wires provide mechanical strength to withstand severe installation and operating conditions, while achieving conductivity to control temperature rise during short circuit conditions. Each optical fiber is clearly distinguishable utilizing a fiber identification system consisting of coloring and the number of ring marks on it. This compact design features high mechanical strength and fault current rating within a smaller diameter. The smaller diameter also results in excellent sag tension performance. Multi loose tube type: The fibers is placed loosely in a sealed and water resistant stainless steel tube filled with water blocking gel. Two or three stainless steel optical tubes are helically stranded in the inner layer of a multiple-layer cable. The multi loose tube type is designed mostly for very high fiber count requirement over 48 with the maximum fiber count reaching 144. The multi loose tube type can meet the requirement of huge cross and large current capacity. The optical fiber is made of high pure silica and germanium doped silica. UV curable acrylate material is applied over fiber cladding as optical fiber primary protective coating. The detail data of optical fiber performance are shown in the following table. Optical fiber uses special spun device successfully controlled the value of PMD, and makes sure that it can keep stable in cabling. • IEC 61232 Aluminum – clad steel wire for electrical purposes • IEC 60104 Aluminum magnesium-silicon alloy wire for overhead line conductors • IEC 61089 Round wire concentric lay overhead electrical stranded conductors • Fiber is Corning SMF-28e+ Optical Fiber Options • Hardware for Installation Notes • Reel lengths must be defined at time of purchase to assist client with reducing waste, and to reduce splicing required during installation. • Please contact AWG for full detailed technical specifications, including PLS CADD data or Stress Creep data.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

607 20150407

FIBER OPTIC CABLES

Standards • IEC 60793-1 Optical fiber Part 1: Generic specifications • IEC 60793-2 Optical fiber Part 2: Product specifications • ITU-T G.652 Characteristics of a single-mode optical fiber cable • ITU-T G.655 Characteristics of a non-zero dispersion-shifted single-mode optical fiber and Cable • EIA/TIA 598 Color code of fiber optic cables • IEC 60794-4-10 Aerial optical cables along electrical power lines – Family specification for OPGW • IEC 60794-1-2 Optical fiber cables-Part 1-2: Generic specification - Basic optical cable test procedures • IEEE1138-2009 IEEE Standard for testing and performance for optical ground wire (OPGW) for use on electric utility power lines

OPGW Optical Ground Wire Item #

Fibers

Total Conductor Area (in2)

Total Conductor Area (mm2)

Overall Diameter (in)

Overall Diameter (mm)

Weight (lb/ft)

Weight (kg/km)

RBS (lb)

RBS (kb)

51

0.1273

85.05

0.484

12.3

0.321

0.478

17390

7888

46

0.1202

80.34

0.484

12.3

0.313

0.466

16107

7306

97

0.1603

107.13

0.544

13.8

0.338

0.503

16984

7704

121

0.1722

115.05

0.563

14.3

0.328

0.488

15611

7081

147

0.2046

136.72

0.630

16

0.472

0.702

24048

10908

154

0.2046

136.72

0.630

16

0.450

0.67

22384

10153

186

0.2246

150.11

0.662

16.8

0.499

0.742

24183

10969

134

0.1926

128.68

0.630

16

0.449

0.668

21865

9918

134

0.1926

128.68

0.630

16

0.449

0.668

21934

9949

161

0.2114

141.29

0.662

16.8

0.499

0.743

23598

10704

FIBER OPTIC CABLES

SINGLE STAINLESS STEEL TUBE OPGW-2S1/24 (M85/R77-51) 24 OPGW-2S2/18 (M80/R72-46) 36 OPGW-2S1/24 (M107/R76-97) 24 OPGW-2S1/24 (M115/R69-121) 24 OPGW-2S42/48 (M137/R107-147) 96 OPGW-2S2/48 (M137/R100-154) 96 OPGW-2S2/48 (M150/R107-186) 96 OPGW-2S3/48 (M129/R97-134) 144 OPGW-2S3/48 (M129/R98-134) 144 OPGW-2S3/48 (M141/R105-161) 144

Fault Current (KA2sec)

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 607 20150407

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

OPGW Optical Ground Wire Item #

Fault Current (KA2sec)

Total Conductor Area (in2)

Total Conductor Area (mm2)

Overall Diameter (in)

Overall Diameter (mm)

Weight (lb/ft)

Weight (kg/km)

RBS (lb)

RBS (kb)

8

43

0.1195

79.88

0.496

12.6

0.300

0.447

16197

7347

8

63

0.1195

79.88

0.516

13.1

0.272

0.404

11338

5143

8

88

0.1694

113.19

0.571

14.5

0.421

0.626

22902

10388

8

101

0.1694

113.19

0.571

14.5

0.369

0.549

15410

6990

12

43

0.1195

79.88

0.496

12.6

0.301

0.448

16219

7357

12

63

0.1195

79.88

0.516

13.1

0.272

0.404

11338

5143

12

67

0.1494

99.86

0.544

13.8

0.376

0.56

20426

9265

12

78

0.1461

97.62

0.544

13.8

0.329

0.49

13790

6255

24

69

0.1481

98.96

0.540

13.7

0.362

0.538

19257

8735

24

83

0.1481

98.96

0.540

13.7

0.298

0.443

12350

5602

24

83

0.1622

108.39

0.559

14.2

0.393

0.585

21147

9592

24

101

0.1622

108.39

0.559

14.2

0.323

0.481

13565

6153

36

98

0.1741

116.36

0.595

15.1

0.417

0.621

21619

9806

36

111

0.1741

116.36

0.595

15.1

0.368

0.548

14758

6694

36

124

0.1978

132.14

0.626

15.9

0.478

0.712

25150

11408

36

141

0.1978

132.14

0.626

15.9

0.422

0.628

17119

7765

48

153

0.2148

143.52

0.646

16.4

0.499

0.742

25510

11571

48

179

0.2196

146.73

0.650

16.5

0.454

0.676

18087

8204

48

253

0.2814

188

0.725

18.4

0.673

1.001

35139

15939

48

305

0.2814

188

0.725

18.4

0.555

0.826

22699

10296

72

159

0.2178

145.55

0.677

17.2

0.504

0.75

25556

11592

72

184

0.2206

147.41

0.677

17.2

0.435

0.648

17727

8041

72

188

0.2394

160

0.701

17.8

0.569

0.846

29672

13459

72

213

0.2394

160

0.701

17.8

0.503

0.749

20585

9337

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

607 20150407

FIBER OPTIC CABLES

ALUMINUM TUBE OPGW(LAL_Tube)-1S8 (M80/R72-43) OPGW(LAL_Tube)-1S8 (M87/R50-63) OPGW(LAL_Tube)-1S8 (M113/R102-88) OPGW(LAL_Tube)-1S8 (M113/R69-101) OPGW(LAL_Tube)-1S12 (M80/R72-43) OPGW(LAL_Tube)-1S12 (M87/R50-63) OPGW(L-AL_Tube)-1S12 (M100/R91-67) OPGW(LAL_Tube)-1S12 (M100/R61-78) OPGW(LAL_Tube)-1S24 (M99/R86-69) OPGW(LAL_Tube)-1S24 (M99/R55-83) OPGW(LAL_Tube)-1S24 (M108/R94-83) OPGW(LAL_Tube)-1S24 (M108/R60-101) OPGW(LAL_Tube)-1S36 (M116/R96-98) OPGW(LAL_Tube)-1S36 (M116/R66-111) OPGW(LAL_Tube)-1S36 (M132/R112-124) OPGW(LAL_Tube)-1S36 (M132/R76-141) OPGW(LAL_Tube)-1S48 (M144/R113-153) OPGW(LAL_Tube)-1S48 (M147/R80-179) OPGW(LAL_Tube)-1S48 (M188/R156-253) OPGW(LAL_Tube)-1S48 (M188/R101-305) OPGW(LAL_Tube)-1S72 (M146/R114-159) OPGW(LAL_Tube)-1S72 (M146/R79-184) OPGW(LAL_Tube)-1S72 (M160/R132-188) OPGW(LAL_Tube)-1S72 (M160/R92-213)

Fibers

OPGW Optical Ground Wire Item #

Fibers

Total Conductor Area (in2)

Total Conductor Area (mm2)

Overall Diameter (in)

Overall Diameter (mm)

Weight (lb/ft)

Weight (kg/km)

RBS (lb)

RBS (kb)

44

0.1218

81.39

0.469

11.9

0.316

0.47

17075

7745

55

0.1218

81.39

0.469

11.9

0.259

0.385

10820

4908

55

0.1330

88.87

0.488

12.4

0.327

0.487

16850

7643

66

0.1330

88.87

0.488

12.4

0.280

0.416

11541

5235

64

0.1430

95.56

0.504

12.8

0.351

0.522

18470

8378

76

0.1430

95.56

0.504

12.8

0.299

0.445

12644

5735

66

0.1481

98.99

0.512

13

0.378

0.562

20831

9449

76

0.1481

98.99

0.512

13

0.331

0.493

14174

6429

76

0.1586

106.01

0.528

13.4

0.403

0.599

22024

9990

94

0.1586

106.01

0.528

13.4

0.330

0.491

14105

6398

FIBER OPTIC CABLES

ALUMINUM CLAD STEEL TUBE OPGW(ALTube)-1S48 (M81/R76-44) 48 OPGW(ALTube)-1S48 (M81/R48-55) 48 OPGW(ALTube)-1S48 (M89/R75-55) 48 OPGW(ALTube)-1S48 (M89/R51-66) 48 OPGW(ALTube)-1S48 (M96/R82-64) 48 OPGW(AL-Tube)-1S48 (M96/R56-76) 48 OPGW(ALTube)-1S48 (M99/R93-66) 48 OPGW(ALTube)-1S48 (M99/R63-76) 48 OPGW(ALTube)-1S48 (M106/R98-76) 48 OPGW(ALTube)-1S48 (M106/R63-94) 48

Fault Current (KA2sec)

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 607 20150407

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

OPGW Optical Ground Wire Designation

Fiber Count (max)

Fault Duty (kA2s)

RBS (lb)

Weight (lb/ft)

Area (in2)

Sag10 Chart

0.528 0.528 0.472 0.472 0.512 0.528 0.531 0.534 0.555 0.528 0.555 0.555 0.571 0.571 0.472 0.472 0.472 0.602 0.602 0.606 0.646 0.646 0.472 0.472 0.528 0.472 0.506 0.528 0.531 0.591 0.506 0.602 0.620 0.646 0.646 0.646 0.785 0.836

74.8 71.9 46.3 48.1 75.1 68.9 74.1 88.0 84.5 71.9 91.7 103.9 109.8 116.2 41.9 49.4 28.8 118.0 123.1 153.9 190.1 179.7 37.7 39.2 71.9 43.3 62.9 65.1 67.0 106.4 54.4 104.9 146.6 167.8 172.4 155.9 426.6 498.6

19,468 20,620 16,536 15,613 13,987 21,771 20,928 15,529 24,105 20,620 21,555 16,455 20,098 17,402 15,310 10,692 20,851 26,909 25,716 17,073 21,902 25,249 14,083 13,159 20,620 10,389 12,292 19,090 19,376 22,478 11,915 24,642 18,418 21,336 19,662 24,617 19,735 23,121

0.365 0.380 0.305 0.293 0.286 0.395 0.386 0.316 0.438 0.380 0.404 0.337 0.391 0.356 0.293 0.232 0.366 0.502 0.479 0.368 0.454 0.499 0.281 0.269 0.380 0.232 0.267 0.365 0.370 0.435 0.267 0.476 0.397 0.451 0.428 0.517 0.504 0.599

0.16 0.16 0.13 0.13 0.15 0.16 0.16 0.16 0.17 0.16 0.17 0.17 0.18 0.18 0.12 0.12 0.12 0.20 0.20 0.21 0.24 0.24 0.11 0.11 0.16 0.11 0.13 0.15 0.15 0.19 0.13 0.19 0.21 0.22 0.22 0.22 0.34 0.37

1-1461 1-1457 1-1457 1-1461 1-1455 1-1427 1-1457 1-1170 1-1427 1-1457 1-1461 1-1455 1-536 1-1455 1-1450 1-1439 1-1140 1-1453 1-1450 1-1441 1-1455 1-536 1-1461 1-1444 1-1457 1-1439 1-1439 1-1450 1-1450 1-1461 1-1455 1-1457 1-1439 1-1170 1-1439 1-1427 1-1056 1-1056

Notes: *Many other designs are also available. *Specifications are subject to change without notice.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

607 20150407

FIBER OPTIC CABLES

MULTI STAINLESS STEEL TUBE 39AY68ACS-1C-1 12 39AY68ACS-1C-2 12 27AY59ACS-1C 16 32AY54ACS-1C 16 64AY37ACS-1C 20 34AY73ACS-1C 24 34AY74ACS-1C 24 68AY42ACS-1C 24 31AY87ACS-1C 24 39AY68ACS-1C-3 24 44AY75ACS-1C 24 75AY44ACS-1C 24 59AY66ACS-1C 24 79AY46ACS-1C 24 27AY59ACS-2C 32 59AY27ACS-2C 32 86ACS-2C 32 40AY100ACS-1C 36 56AY83ACS-1C 36 103AY40ACS-1C 36 101AY59ACS-1C 36 84AY76ACS-1C 36 27AY59ACS-3C 48 32AY54ACS-3C 48 39AY68ACS-1C-4 48 59AY27ACS-3C 48 67AY32ACS-2C 48 34AY73ACS-2C 48 34AY74ACS-2C 48 49AY85ACS-2C 48 67AY32ACS-3C 72 40AY100ACS-2C 72 101AY47ACS-2C 72 101AY59ACS-2C 72 110AY51ACS-2C 72 59AY101ACS(27)-2C 72 191AY45ACS-3C 72 194AY74ACS-3C 144

Diameter (in)

FIBER OPTIC CABLES

Notes

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Installation Manual for OPGW Cable This handbook is formulated on IEEE 1138-2008 and IEEE 524-1992 etc. OPGW has two functions: electric aerial ground wire and fiber communication. It is constituted of AS wire, AA wire and stainless steel tube op-unit. The installation rules of OPGW are almost the same as the engineering and installation modes of traditional aerial electric power wire, referring to electric power company's aerial transmit circuitry installation skills, management and other related files. In order to guarantee the installation of OPGW and avoid the waste of personnel and material resources, we compile this handbook as the reference, not instead of any other manufacturers' installation instructions. OPGW is usually installed on the top of pole of the electric power aerial wire. The following disadvantages should be considered: vibration caused by wind, hurricane, ice thickness, unsteady operation caused by temperature, and possible thunder attack, short circuit ere. Therefore, detailed engineering program should be formulated according to different structures of OPGW and specific route conditions. According to design requirement, OPGW should be allotted correctly; every tray of optical fiber cable should he installed in the appointed part of route and should be laid according to engineering chart operation file. Please click HERE to download the complete intallation manual.

FIBER OPTIC CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

608 20150407

FIBER OPTIC CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

OPGW Cable & System Information Guide for Hardware Selection The following outline describes the OPGW cable information required to select proper cable attachment hardware and accessories. Most of the cable information can be found in the cable specification — it is recommended that this information be gathered along with the information about the cable system. Submit this information to American Wire Group to verify proper application. A. CABLE INFORMATION REQUIRED for DEAD-ENDS AND SUSPENSIONS 1. CABLE SPECIFICATIONS/Cable Specification Sheet Data a. Cable Diameter: Overall outer diameter of the OPGW. b. Cable Construction Strand Configuration: Lay Direction of outer wire strands, Distribution and Location of individual strand materials in a cross-section, Number of strand layers. c. Rated Breaking Strength d. Fault Current 2. CABLE SYSTEM a. Maximum Vertical Load at Hardware Attachment b. Line Angles In addition to the outline above, other products offered for OPGW applications require further information as listed in Part B below. B. ADDITIONAL INFORMATION FOR OTHER HARDWARE ACCESSORIES 1. Splice Closures, Closures, and Domes a. Fiber Count b. Fiber Type c. Fiber Optic Element Configuration d. Type of Buffer Tubes (plastic or stainless steel) e. Core construction (Solid, Aluminum Tube, Aluminum Channel), 2. Spiral Vibration Damper a. Span Lengths b. Final Tension at the Average Annual Minimum Temperature (AAMT) c. Terrain 3. FITTINGS (Y-Clevis, Clevis Eye, Yoke Plates), Ground Wire, Downlead Cushions, Cable Storage a. Interface at structure b. Type of Structure (Wood Pole, Concrete, Steel, Lattice Tower) c. Ground Wire Material, Bonding Material HARDWARE TESTS The IEEE 1138 Test Standard for OPGW includes a series of tests that require suitable hardware to demonstrate system performance. System tests include Tensile Strength, Vibration Test, and Galloping Tests among others. System tests require dead-ends and suspensions that can survive the test parameters and prove cable/hardware compatibility.

FIBER OPTIC CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

602 20140110

FIBER OPTIC CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

ADSS All Dielectric Self-Supporting Fiber Optic Cable Applications The “All Dielectric Self-Supporting (ADSS)” cables are designed for aerial self-supporting applications at short, medium and long span distances. ADSS cables offer a rapid and economical means for deploying optical fiber cables along existing aerial rights-of-way. They are being deployed by cable television operators, telephone companies, municipalities and emerging network operators, in addition to electric power utilities. Construction The ADSS cable consists of a number of tubes/elements according to the specified number of fibers. The elements are usually fiber-containing tubes; however fillers may be used to preserve the cable geometry. Two to twelve color-coded fibers are loosely laid in each tube which is filled with a water-blocking gel. The tubes are stranded around a dielectric central strength member and bound in a jacket. A water-swelling tape is helically wrapped around the cable core. Aramid yarn strength members are helically laid to supply peripheral strengthening of the cable. The outer jacket is tightly bound over the aramid yarn layer. For long span applications a double jacket design can be considered. A ripcord is located under each jacket layer to facilitate its removal. For up to 30 fiber cables, the “ADSB” design is applicable, for 32-144 fibers the “ADSC” design is applicable. Dry cable designs, ballistic protection and other cable designs are available upon request.. Standards • Cables are designed for aerial installation according to IEEE-P1 222 • Cables tested according to TIA/EIA-455 and IEC-60794-1. • Cables meet or exceed Telcordia (Bellcore) requirements for outside plant cables (GR-20) when the appropriate options are chosen. Default Jacket Colors PE HFFR SM Fibers Black Yellow MM Fibers Black Orange Other jacket colors may be available, please specify. Sag Chart Below are the coefficients for a standard ADSS cable containing 32 to 60 fibers in 5 tubes with a single outer jacket. The cable can be used in a span of 450 feet with NESC light conditions, 300 feet for NESC medium and 240 feet for NESC heavy conditions. • Cross section area 0.196 in^2 • Outside diameter 0.5 in • Unit weight 0.081 lbs/ft • Ultimate tension 5800 lbs The following values are calculated at 68°F • Final modulus of elasticity 3248850 psi • Thermal expansion coefficient -2.78e-7°F • Stress strain A1 2973280 psi • Creep A1 2625190 psi

Item #

Number of Elements

2-30 ADSB 2-30 ADSB 2-30 ADSB 2-30 ADSB 2-30 ADSB 2-30 ADSB 2-30 ADSB 2-30 ADSB 2-30 ADSB 32-60 ADSC 32-60 ADSC

5 5 5 5 5 5 5 5 5 5 5

Cable Weight (kg/km) 105 105 105 105 105 105 105 105 105 120 120

Cable Installation Diameter Tension (mm) (N)(2) 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 12.7 12.7

400 525 800 860 985 1255 1520 1785 1920 425 570

Span (m) (m)

Sag in Light (m)

Tension in Light (N)

Sag in Medium (m)

Tension in Medium (N)

Sag in Heavy (m)

Tension in Heavy (N)

30 40 60 70 80 100 120 135 150 30 40

0.16 0.22 0.37 0.46 0.54 0.71 0.89 1.01 1.16 0.16 0.23

1230 1540 2100 2300 2560 3040 3500 3870 4170 1310 1630

0.48 0.69 1.16 1.42 1.68 2.25 2.80 3.23 3.70 0.49 0.71

1600 1970 2650 2930 3240 3820 4380 4810 5180 1650 2030

0.66 0.95 1.6 2.27 2.33 — — — — 0.67 0.96

2370 2940 3900 4320 4755 — — — — 2430 3000

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

603 20140110

FIBER OPTIC CABLES

ADSS-1 ADSS-2 ADSS-3 ADSS-4 ADSS-5 ADSS-6 ADSS-7 ADSS-8 ADSS-9 ADSS-10 ADSS-11

ADS Series

ADSS All Dielectric Self-Supporting Fiber Optic Cable

FIBER OPTIC CABLES

Item #

ADSS-12 ADSS-13 ADSS-14 ADSS-15 ADSS-16 ADSS-17 ADSS-18 ADSS-19 ADSS-20 ADSS-21 ADSS-22 ADSS-23 ADSS-24 ADSS-25 ADSS-26 ADSS-27 ADSS-28 ADSS-29 ADSS-30 ADSS-31 ADSS-32 ADSS-33 ADSS-34 ADSS-35 ADSS-36 ADSS-37 ADSS-38 ADSS-39 ADSS-40 ADSS-41 ADSS-42 ADSS-43 ADSS-44 ADSS-45 ADSS-46 ADSS-47 ADSS-48 ADSS-49 ADSS-50 ADSS-51 ADSS-52 ADSS-53

ADS Series

Number of Elements

32-60 ADSC 32-60 ADSC 32-60 ADSC 32-60 ADSC 32-60 ADSC 32-60 ADSC 32-60 ADSC 32-60 ADSC 62-72 ADSC 62-72 ADSC 62-72 ADSC 62-72 ADSC 62-72 ADSC 62-72 ADSC 62-72 ADSC 62-72 ADSC 62-72 ADSC 62-72 ADSC 74-96 ADSC 74-96 ADSC 74-96 ADSC 74-96 ADSC 74-96 ADSC 74-96 ADSC 74-96 ADSC 74-96 ADSC 74-96 ADSC 98-126 ADSC 98-126 ADSC 98-126 ADSC 98-126 ADSC 98-126 ADSC 98-126 ADSC 98-126 ADSC 98-126 ADSC 122-144 ADSC 122-144 ADSC 122-144 ADSC 122-144 ADSC 122-144 ADSC 122-144 ADSC 122-144 ADSC

5 5 5 5 5 5 5 5 6 6 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 10 10 10 10 10 10 10 10 12 12 12 12 12 12 12

Cable Weight (kg/km) 120 120 120 120 120 120 120 120 125 125 125 125 125 125 125 125 125 125 180 180 180 180 180 180 180 180 180 220 220 220 220 220 220 220 220 280 280 280 280 280 280 280

Cable Installation Diameter Tension (mm) (N)(2) 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 12.7 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 16 16 16 16 16 16 16 16 17.2 17.2 17.2 17.2 17.2 17.2 17.2

715 845 990 1120 1500 1780 1936 2200 443 580 795 950 1085 1240 1530 180 2080 2340 580 820 1000 1220 1400 1640 1960 2360 2640 834 1100 1290 1590 1860 2150 2690 3250 1030 1340 1720 2030 2440 2750 3470

Span (m) (m)

Sag in Light (m)

Tension in Light (N)

Sag in Medium (m)

Tension in Medium (N)

Sag in Heavy (m)

Tension in Heavy (N)

50 60 70 80 100 120 135 150 30 40 50 60 70 80 100 120 135 150 30 40 50 60 70 80 100 120 135 30 40 50 60 70 80 100 120 30 40 50 60 70 80 100

0.30 0.38 0.45 0.54 0.70 0.88 1.02 1.16 0.16 0.24 0.30 0.38 0.46 0.54 0.72 0.90 1.04 1.18 0.17 0.24 0.32 0.4 0.49 0.57 0.76 0.94 1.09 0.19 0.27 0.35 0.44 0.53 0.62 0.81 1.00 0.21 0.29 0.37 0.47 0.56 0.65 0.85

1940 2220 2520 2780 3340 3840 4150 4530 1320 1640 2000 2300 2570 2850 3350 3830 4220 4600 1500 1890 2220 2600 2890 3240 3790 4390 4800 1730 2150 2500 2910 3290 3680 4400 5114 1910 2380 2900 3300 3800 4215 5070

0.94 1.17 1.43 1.69 2.22 2.79 3.26 — 0.50 0.71 0.92 1.16 1.42 1.68 2.22 2.80 3.23 — 0.5 0.7 0.94 1.17 1.42 1.67 2.23 — — 0.49 0.70 0.93 1.17 1.40 1.66 2.17 — 0.49 0.71 0.91 1.15 1.38 1.62 —

2400 2750 3080 3390 4050 4628 5020 — 1640 2040 2470 2800 3130 3450 4070 4650 5100 — 1800 2260 2630 3060 3415 3800 4450 — — 2015 2500 2920 3360 3800 4215 5030 — 2200 2710 3280 3740 4270 4725 —

1.28 1.62 1.97 2.35 — — — — 0.67 0.97 1.26 1.60 1.96 2.32 — — — — 0.67 0.96 1.28 1.61 1.97 — — — — 0.66 0.94 1.27 1.61 1.94 — — — 0.66 0.95 1.25 1.58 — — —

3530 4020 4500 4990 — — — — 2500 3000 3590 4080 4540 5000 — — — — 2590 3220 3770 4330 4820 — — — — 2810 3500 4070 4660 5220 — — — 3030 3720 4400 5030 — — —

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 603 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Loose Tube Fiber Optic Cable Applications Multi-purpose Outdoor — Aerial Lashed, Duct, Direct Buried Constructions Dielectric, Armored, Double Armored Fiber Count 2 to 432 fibers in Color-coded Buffer Tubes Fiber Types Singlemode / Multimode Options Gel-Filled Core / Steel Central Member / Copper Pair(s) Other versions Central / Heavy Duty / Indoor-Outdoor Performance ANSI/ICEA, IEC, RUS, Telcordia GR-20 Mechanical Specifications Installation [+] Maximum installation load 600 lbf (2670 N) [+] Maximum operation load 180 lbf (800 N) Temperature Range [+] Shipping and Storage -40°F to +167°F (-40°C to +75°C) [+] Installation -22°F to +140°F (-30°C to +60°C) [+] Operation -40°F to +158°F (-40°C to +70°C)

Item #

Fiber Count

Dielectric (Non-Armored) LT-DNA-1 2 to 60 LT-DNA-2 62 to 72 LT-DNA-3 74 to 84 LT-DNA-4 86 to 96 LT-DNA-5 98 to 108 LT-DNA-6 110 to 120 LT-DNA-7 122 to 132 LT-DNA-8 134 to 216 LT-DNA-9 218 to 264 LT-DNA-10 266 to 288 LT-DNA-11 290 to 432*

Number of Buffer Tubes

Diameter (in)

Diameter (mm)

5 6 7 8 9 10 11 18 22 24 18

0.42 0.45 0.49 0.53 0.56 0.60 0.63 0.67 0.74 0.77 0.73

10.6 11.5 12.3 13.4 14.2 15.1 16.1 16.9 18.9 19.6 18.6

Approximate Approximate Cable Cable Weight Weight /MFT /km (lb) (kg) 53 63 72 82 90 99 109 126 153 167 153

79 94 107 122 134 147 162 187 228 248 228

Bend Radius Load (in)

Bend Radius Load (cm)

Bend Radius No Load (in)

Bend Radius No Load (cm)

8 9 10 11 11 12 13 13 15 15 15

21 23 25 27 28 30 32 34 38 39 37

4 5 5 5 6 6 6 7 7 8 7

11 11 12 13 14 15 16 17 19 20 19 FIBER OPTIC CABLES

*Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups. Rated buffer storage length is 8 feet (2.4 meters)

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

604 20140110

Loose Tube Fiber Optic Cable Item #

Fiber Count

Number of Buffer Tubes

FIBER OPTIC CABLES

Single Jacket Armored LT-SJA-1 2 to 60 5 LT-SJA-2 62 to 72 6 LT-SJA-3 74 to 84 7 LT-SJA-4 86 to 96 8 LT-SJA-5 98 to 108 9 LT-SJA-6 110 to 120 10 LT-SJA-7 122 to 132 11 LT-SJA-8 134 to 216 18 LT-SJA-9 218 to 264 22 LT-SJA-10 266 to 288 24 LT-SJA-11 290 to 432* 18 Double Jacket Armored LT-DJA-1 2 to 60 5 LT-DJA-2 62 to 72 6 LT-DJA-3 74 to 84 7 LT-DJA-4 86 to 96 8 LT-DJA-5 98 to 108 9 LT-DJA-6 110 to 120 10 LT-DJA-7 122 to 132 11 LT-DJA-8 134 to 216 18 LT-DJA-9 218 to 264 22 LT-DJA-10 266 to 288 24 LT-DJA-11 290 to 432* 18 Dielectric Double Jacket (Non-Armored) LT-DDJ-1 2 to 60 5 LT-DDJ-2 62 to 72 6 LT-DDJ-3 74 to 84 7 LT-DDJ-4 86 to 96 8 LT-DDJ-5 98 to 108 9 LT-DDJ-6 110 to 120 10 LT-DDJ-7 122 to 132 11 LT-DDJ-8 134 to 216 18 LT-DDJ-9 218 to 264 22 LT-DDJ-10 266 to 288 24 LT-DDJ-11 290 to 432* 18

Diameter (in)

Diameter (mm)

Approximate Approximate Cable Cable Weight Weight /MFT /km (lb) (kg)

Bend Radius Load (in)

Bend Radius Load (cm)

Bend Radius No Load (in)

Bend Radius No Load (cm)

0.48 0.51 0.55 0.59 0.62 0.66 0.69 0.73 0.81 0.84 0.80

12.2 13.0 14.0 15.0 15.8 16.8 17.6 18.6 20.6 21.4 20.3

98 109 122 135 146 161 171 195 231 242 225

146 162 182 201 218 240 255 291 344 360 225

10 10 11 12 12 13 14 15 16 17 16

24 26 28 30 32 34 35 37 41 43 41

7 8 8 9 9 10 10 11 12 13 12

18 20 21 23 24 25 26 28 31 32 31

0.54 0.57 0.61 0.65 0.68 0.72 0.75 0.79 0.87 0.90 0.87

13.8 14.5 15.5 16.6 17.3 18.3 19.1 20.1 22.1 22.9 22.1

118 138 153 170 182 201 212 239 283 295 279

175 205 228 253 272 300 315 356 421 439 415

11 11 12 13 14 14 15 16 17 18 17

28 29 31 33 35 37 38 40 44 46 44

8 9 9 10 10 11 11 12 13 14 13

21 22 23 25 26 28 29 30 33 34 33

0.48 0.51 0.55 0.59 0.62 0.66 0.69 0.73 0.80 0.83 0.79

12.1 13.0 13.9 15.0 15.7 16.7 17.6 18.4 20.4 21.2 20.1

68 83 91 103 111 123 132 149 184 192 182

101 124 136 153 165 182 196 221 274 286 271

10 10 11 12 12 13 14 15 16 17 16

24 26 28 30 31 33 35 37 41 42 41

5 5 5 6 6 7 7 7 8 8 8

12 13 14 15 16 17 18 18 20 21 20

*Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups. Rated buffer storage length is 8 feet (2.4 meters)

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 604 20140110

Informatio on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Loose Tube Fiber Optic Cable Item #

Fiber Count

Double Jacket Double Armored LT-DJDA-1 2 to 60 LT-DJDA-2 62 to 72 LT-DJDA-3 74 to 84 LT-DJDA-4 86 to 96 LT-DJDA-5 98 to 108 LT-DJDA-6 110 to 120 LT-DJDA-7 122 to 132 LT-DJDA-8 134 to 216 LT-DJDA-9 218 to 264 LT-DJDA-10 266 to 288 LT-DJDA-11 290 to 432* Triple Jacket Double Armored LT-TJDA-1 2 to 60 LT-TJDA-2 62 to 72 LT-TJDA-3 74 to 84 LT-TJDA-4 86 to 96 LT-TJDA-5 98 to 108 LT-TJDA-6 110 to 120 LT-TJDA-7 122 to 132 LT-TJDA-8 134 to 216 LT-TJDA-9 218 to 264 LT-TJDA-10 266 to 288 LT-TJDA-11 290 to 432*

Number of Buffer Tubes

Diameter (in)

Diameter (mm)

Approximate Approximate Cable Cable Weight Weight /MFT /km (lb) (kg)

5 6 7 8 9 10 11 18 22 24 18

0.67 0.70 0.74 0.78 0.81 0.85 0.88 0.92 1.00 1.03 1.01

17.1 17.8 18.8 19.9 20.6 21.6 22.4 23.4 25.5 26.2 25.7

205 232 253 274 288 315 330 359 414 429 416

5 6 7 8 9 10 11 18 22 24 18

0.73 0.76 0.80 0.84 0.87 0.91 0.94 0.98 1.06 1.09 1.08

18.6 19.4 20.4 21.4 22.1 23.2 23.9 24.9 27.0 27.7 27.4

235 270 292 317 333 359 377 412 468 488 486

Bend Radius Load (in)

Bend Radius Load (cm)

Bend Radius No Load (in)

Bend Radius No Load (cm)

306 346 377 408 428 468 492 535 616 638 619

13 14 15 16 16 17 18 18 20 21 20

34 36 38 40 41 43 45 47 50 52 51

10 11 11 12 12 13 13 14 15 15 15

26 27 28 30 31 32 34 35 38 39 38

350 402 434 472 495 534 561 613 696 727 723

15 15 16 17 17 18 19 20 21 22 22

37 39 41 43 44 46 48 50 54 55 55

11 11 12 13 13 14 14 15 16 16 16

28 29 31 32 33 35 36 37 40 42 42

*Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups. Rated buffer storage length is 8 feet (2.4 meters)

FIBER OPTIC CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

604 20140110

FIBER OPTIC CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Loose Tube Fiber Optic Cable for Direct Burial (Polyethylene Duct) PBT Tube or PE filler Optical fibers Central member Central member jacket Dielectric strength elements Outer PE jacket Water-blocking material

Ripcord

Application Single jacket loose tube cable with a dielectric central strength member, reinforced with glass yarns and polyethylene jacket, designed for outdoor applications, for direct installations in duct. The cable is supplied in UV resistant high density polyethylene (HDPE) duct. Construction • Up to 12 optical fibers are enclosed in a polybutylene terephthalate (PBT) tubes. • Up to 24 tubes are stranded around jacketed dielectric central member together with PE fillers to form the cable core. • The fibers and tubes are color coded for easy identification. • All the interstices in the cable core are filled with a water blocking materials to prevent water penetration. Water swelling glass yarns are laid over the cable core to serve as peripheral dielectric strength members. • A polyethylene jacket extruded over the glass yarns provides the final cable shape and protection. A ripcord is provided under the jacket to facilitate its removal. • The cable is inserted into UV resistant high density polyethylene duct for wide range of uses including extreme temperatures, abrasive and high tension applications in underground installations. Cable Handling Minimum bend radius with load Minimum bend radius with no load Minimum bend radius, storage coils Maximum rated cable load (MRCL) Maximum long term load

15 x OD 10 x OD 10 x OD 600 lbs (2700N) 180 lbs (800N)

Temperature Range Installation Operation Storage

-300°C to 600°C (-220°F to 1400°F) -600°C to 700°C (-760°F to 1580°F) -400°C to 750°C (-400°F to 1670°F)

Polyethylene Duct Characteristics General specification: The duct is manufactured from virgin high density polyethylene The ducts are supplied with smooth walls and come either in orange color or in black with 3 orange stripes The duct is capable of being coiled in continuous lengths, transported, stored outdoors and subsequently uncoiled for installation – without affecting its properties or performance The duct performs in underground and above-ground installation an ambient temperature range of minus 300°F to 1300°F The duct specified for areal installations is ultraviolet light-resistant by UV light stabilizer protecting the duct for a minimum of 12 months in direct sunlight The duct is bent to a minimum (supported) radius of 10 outer diameters

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

606 20150407

FIBER OPTIC CABLES

Tests on finishing duct are performed in accordance with: • ASTM D3035 Polyethylene Plastic Pipe Based on Controlled Outside Diameter • ASTM D1248 Polyethylene Plastics Molding and Extrusion Materials (Type III, Class A, B or C, Category 5, grade P34) • ASTM D1693 Environmental Stress Cracking of Ethylene Plastics (Cond. B, F20/96 HRS) • ASTM D1238 Flow Rates of Thermoplastics by extrusion Plastometer • ASTM D638 Tensile properties of Plastics • ASTM D3350 Polyethylene Plastic Pipe and Fitting Materials (Cell #335440) • NEMA TC 7 Smooth-wall Coilable Polyethylene Electrical Plastic Duct

Loose Tube Fiber Optic Cable for Direct Burial (Polyethylene Duct) Cable Nominal Dimensions and Weight FIBER COUNT 2-60

61-72

73-96

97-120

121-144

145-216

217-240

241-288

Cable Outer Diameter Cable Weight

0.42 10.7 53 79

0.49 12.5 69 103

0.56 14.1 97 145

0.62 15.7 112 166

0.61 15.4 97 145

0.64 16.2 109 162

0.71 18 134 200

inch mm lb/kft kg/km

0.4 10.1 47 70

Fiber Characteristics PHYSICAL CHARACTERISTICS Core Diameter Clad Diameter Core/Clad Concentricity Error (Offset) Coating diameter Tensile proof test OPTICAL CHARACTERISTICS Attenuation for Wavelength at 1310 nm Attenuation for Wavelength at 1550 nm Attenuation for Wavelength at 850 nm Attenuation for Wavelength at 1300 nm Zero Dispersion Wavelength (λ0) MODE FIELD DIAMETER for wavelength 1310 nm for wavelength 1550 nm Cut-off wavelength (λcc)

Single Mode

μm μm μm μm kpsi

125.0 ± 0.7 ≤ 0.5, 96 hours NPR

* NPR - Not Pressure Rated

Ultraviolet Protection Non-black conduit shall contain sufficient protection against UV radiation for a period not less than one year. Black conduit contains sufficient protection against UV radiation in long term above ground applications. *Available with smooth or ribbed interior wall

Item #

Nominal Size

Nominal Outside Diameter (in)

Minimum Wall Thickness (in)

Nominal Inner Diameter (in)

Min. Bend Radius Unsupported (in)

Max. Pulling Tension (lb)

Weight /MFT (lb)

SDR11-13 SDR11-1/2 SDR11-3/4 SDR11-1 SDR11-1-1/4 SDR11-1-1/2 SDR11-2 SDR11-3 SDR11-4 SDR 13.5

13mm 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 3" 4"

0.625 0.840 1.050 1.315 1.660 1.900 2.375 3.500 4.500

0.055 0.076 0.095 0.120 0.151 0.173 0.216 0.318 0.409

0.500 0.668 0.840 1.055 1.338 1.533 1.917 2.826 3.633

8 10 12 14 18 20 26 48 60

210 390 605 950 1520 1760 3105 6740 11145

46 85 130 204 320 416 640 1386 2295

SDR13.5-1/2 SDR13.5-3/4 SDR13.5-1 SDR13.5-1-1/4 SDR13.5-1-1/2 SDR13.5-2 SDR13.5-3 SDR13.5-4

1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 3" 4"

0.840 1.050 1.315 1.660 1.900 2.375 3.500 4.500

0.062 0.078 0.097 0.123 0.141 0.176 0.259 0.333

0.696 0.874 1.101 1.394 1.598 2.002 2.951 3.794

10 12 14 18 20 26 48 60

320 505 790 1260 1455 2580 5590 9250

72 111 169 265 344 532 1154 1905

SDR 11

FIBER OPTIC CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

605 20140110

FIBER OPTIC CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

High Density Polyethylene Duct Application High Density Polyethelene Duct has been tested and proven under the most severe conditions. From extreme temperatures to abrasive and high-tension applications in underground installations, HDPE provides quality service and economy in a wide range of uses. As a smooth and flexible duct for cable, HDPE is unequaled for ease of installation and continuous strength. Description The duct shall be manufactured from virgin high-density polyethylene. The addition of clean rework material is permissible if generated in the manufacturer’s own plant. The ducts are supplied with either smooth, ribbed, or corrugated walls and come in a multitude of colors. The duct shall be capable of being coiled (reeled) in continuous lengths, transported, stored outdoors and subsequently uncoiled for installation - without affecting its properties or performance. Environmental Performance The duct shall perform in underground and aboveground temperature range of minus 300° temperature range of minus 300°F to 1300°F without degradation of material properties. The duct specified for aerial installation shall be ultraviolet light resistant. It shall be possible to bend the duct to a minimum (supported) radius of 10 diameters. Workmanship The duct shall be free of visible cracks, holes or other physical defects that would degrade its performance. It shall be as uniform as practicable in respect to overall dimensions, color, density, thickness, etc. Color The duct for exposed areas (black) shall have a minimum of carbon black. All other colors shall have a UV light stabilizer which will protect the duct for a minimum of 12 months in direct sunlight. Markings The duct shall have a durable identification showing the name or trademark of the manufacturer, duct size (i.e., 2” IPS SCH-80), date and reference code. Duct for electrical cable should have “CAUTION - HIGH-VOLTAGE” printed at regular intervals. Other special markings can be agreed upon between the buyer and seller. Capping The open ends of each length of reeled duct shall be sealed by plastic caps to prevent the entrance of dirt and/or moisture. Pull Rope and Lubricant The duct should be equipped with a factory installed rope or tape and pre-lubed to aid in the installation of cable. The rope can be provided with varying strengths as needed for a particular installation. Check with a manufacturer for specifications. Couplings Couplings should be available to quickly connect the duct and should be air and watertight (i.e., Duct-Lok type couplings in either plastic or aluminum, depending on type of installation). Packaging The duct should be provided on lightweight metal reels in maximum lengths possible with no joints or splices. This will keep coupling requirements to a minimum. Special reel sizes and/ or dimensions should be available for special installations. Corrosion The duct shall be resistant to most harsh chemicals and/or protected against degradation due to oxidation or general corrosion.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

609 201802011

FIBER OPTIC CABLES

Installation The duct shall be capable of being direct buried by plowing or trenching with no special consideration to using selective backfill. The duct shall also be capable of being encased in concrete. NOTE: HDPE conduit is manufactured to the dimension and requirements of ASTM F2160. Ovality (out-of-roundness) and curvature are inherent characteristics of coiled, continuous length HDPE conduit. While these conditions are normal and expected and are not a concern in most applications, some installations or applications may require “re-rounding” of the conduit. When this is necessary, ovality should be corrected in the field by processing the conduit through re-rounding and straightening equipment during installation.

High Density Polyethylene Duct Tests on Resins and Finished Duct Since specifications vary from customer to customer, we perform in-house lab tests on resins and finished products which include, but are not limited to the following: • ASTM D3035: Polyethylene Plastic Pipe Based on Controlled Outside Diameter. • ASTM D2447: Polyethylene Plastic Pipe, Schedules 40 • ASTM D2239: Polyethylene Plastic Pipe Based on Controlled Inside Diameter. • ASTM D1248: Polyethylene Plastics Molding and Extrusion Materials. (Type III, Class A, B,or C, Category 5, Grade P34). • ASTM D1693: Environmental Stress-Cracking of Ethylene Plastics. (Cond. B, F20/96 HRS.) • ASTM D1238: Flow Rates of Thermoplastics by Extrusion Plastometer. • ASTM D1505: Density of Plastics by the Density Gradient Technique. • ASTM D638: Tensile Properties of Plastics. • ASTM D3350: Polyethylene Plastic Pipe and Fittings Materials. (Cell # 335440). • NEMA TC 7: Smooth-Wall Coilable Polyethylene Electrical Plastic Duct. other ASTM tests i.e.: Tensile, Impact etc. • ASTM D1505: Density of Plastics by the Density Gradient Technique. • ASTM D638: Tensile Properties of Plastics. • ASTM D2412: Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading. • ASTM D2444: Determination of the Impact resistance of Thermoplastic Pipe and Fittings by Means of a Tup. • ASTM D3485: Smooth-Wall Coilable Polyethylene Conduit for Pre-assembled Wire and Cable. • ASTM F2160: Standard Specifications for Solid Wall High Density Polyethylene (HDPE) Conduit Based on Controlled Outside Diameter (OD). Design Considerations Please refer to our technical data brochure. This shows different design parameters for polyethylene pipe (i.e., Wall Crushings, Wall Buckling, etc.) as per the various SDR (wall thickness) ratings. Special Options Striped Duct - Three longitudinal stripes can be extruded on any standard size of smooth duct of any color. Stripes are approximately 1/8inch in width (varying slightly according to the duct size). There is no additional charge for Striped Duct. Sequentially-Marked Duct - Duct can be ordered with numbering - every two feet - printed on the duct. Cable in Conduit - Cable can be pre-installed in conduit utilizing the same stringent quality control as pre-roped and pre-taped duct. (Request the technical instruction guide for C.I.C. installation.) Fire-Retardant HDPE - AWG offers Fire-Retardant (FR) in any type of duct (orange only). Fire Retardant HDPE has been successfully tested and is offered in the top class, i.e., UL94 V-O only. Because the fire retardant process eliminates UV protection, Fire-Retardant duct must be installed safe from exposure to UV light. All sizes of duct are available with ProPullTM PreLube, ProPullTM Rope or Tape (1130#, 1250#, 1500# or 2500# tensile strength) and spool lengths of your choice up to reel capacity.

FIBER OPTIC CABLES

Selected sizes available with UL Mark.

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 609 20180201

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

High Density Polyethylene Duct TYPICAL THERMAL AND ELECTRICAL PROPERTIES OF HDPE DUCT PROPERTY

TEST METHOD

UNITS

VALUE

Vicat Softening Temp. Heat Distortion Temp. Thermal Expansion Thermal Conductivity Volume Resistivity Surface Resistance Dialectric Strength

ASTM D 1535 ASTM D 648 ASTM D 696 ASTM C 177 DIN 53482 DIN 53482 DIN 53481

°F °F in/in/°F BTU in/ft/hrs/°C Ω/cm Ω KV/cm

255° 172° 1 x 10-4 4.7 >1016 >1013 700-850

TYPICAL PHYSICAL PROPERTIES: HIGH MOLECULAR WEIGHT HDPE PRODUCTS PROPERTY Density (Black) Melting Point Melt Index i2.16 Tensile Yield Strength Elongation at Break Tens. of Modulus of Elast. Flexural Modulus Vicat Softening Temp. Brittleness Temp. Heat Distortion Temp. Thermal Expansion Rockwell Hardness L Shore Hardness D

ASTM (CONDITION)

UNITS

VALUE

D 1505 DSC D 1238 (E) D 638 D 638 (Specimen I) D 638 D 790 D 1525 D 746 D 648 D 696 D 795 D 2240

g/cm3 °F gm/10 min. psi % psi psi °F °F °F in/in/°F — —

0.955 261 .11 3300 800 113.000 136.000 255 ← 103 172 1 x 10-4 49 68

The data listed was determined on press molded test specimens, and may therefore deviate from specimens taken from pipes. Classification Type/Class/Cat./Grade Cell Classification Recommended Designation

D 1248

III/C/5/P34

D 3350

335440 PE 34

Designated tests are made in accordance with current issues of ASTM Standard Testing Methods. Copies of these methods are available, on request, from the America Society for Testing and Materials, 1916 Race Street, Philadelphia PA 19103

FIBER OPTIC CABLES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

609 20180201

FIBER OPTIC CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

PORTABLE POWER CABLES Table of Contents SOOW/SEOOW Control Cable ..............................................................................................701 Welding Cable 600V ICEA Approved 105°C-40°C ................................................................702 Type W RHH/RHW Single Conductor 600/2000V.................................................................703 Type W Magnet Crane Cable Two Conductor 600/2000V....................................................704 Type W Round Multi-Conductor 600/2000V.........................................................................705 Type G Round 600/2000V......................................................................................................706 MP-GC Mine Power Feeder 5kV-15kV ...................................................................................707 SHD-GC Portable Power Cable 2kV-25kV .............................................................................708 Type DLO Diesel Locomotive Cable 2kV ..............................................................................709 Jumper Cable Transformer Lead Wire Non-Shielded 5kV/15kV .........................................710

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

700 20180201

PORTABLE POWER CABLES

www.buyawg.com

PORTABLE POWER CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

SOOW/SEOOW Control Cables Applications Special uses requiring flexibility and mechanical toughness, high environmental resistance and flame retardance. Push button remote controls. Motor control, stage equipment and lighting. Industrial control and robotic systems. Outdoor applications. Suitable and approved for submersion in water. Construction Flexible and tough jacket. Offers -50°C to 105°C temperature extremes. Offers excellent abrasion, ozone, sunlight, chemical and oil resistance as well as water and mold resistant non-wicking lightweight polypropylene fillers. Water resistant with high dielectric insulation. Lightweight, long lasting, easy to carry and easy to handle. All components are recyclable and non-hazardous for environmental landfill disposal. Color coded conductors for easy identification. Standards Federal and Military use under Federal Spec. JC-580B. UL Listed SOOW/SEOOW 600V to NEC Article 400, MSHA approval for flame resistance for mining applications. Color Code • 2/C Black, White • 3/C Black, White, Green • 4/C Black, White, Red, Green • 5/C Black, White, Red, Green, Orange ** Ampacity based on NEC Table 400-5(A) for sized 18/2 thru 10/4 and table 400-5 (B) for sizes 8/2 thru 2/5.

Note Sizes up to 10/4 are UL/CSA/MSHA, sizes 8/2 to 2/5 are non-UL constructions made with wall thicknesses in accordance with industry standards and MSHA approved. The ampacity is provided for engineering information only. The manufacturer cannot recommend or express the use of these ampacities since the exact application may need approval from the authority having local jurisdiction. Above information is subject to engineering changes. Cold temperature rating is -50°C.

Size/ Conductors

Strands

Nominal O.D. (in)

Weight /MFT (lb)

Ampacity

22225 22325 22425 30505 22226 22326 22426 30506 22227 22327 22427 30507 22228 22328 22428 30508 22229 22329 22429 30509

18/2 18/3 18/4 18/5 16/2 16/3 16/4 16/5 14/2 14/3 14/4 14/5 12/2 12/3 12/4 12/5 10/2 10/3 10/4 10/5

16/30 16/30 16/30 16/30 26/30 26/30 26/30 26/30 41/30 41/30 41/30 41/30 65/30 65/30 65/30 65/30 104/30 104/30 104/30 104/30

0.345 0.365 0.39 0.465 0.37 0.39 0.415 0.495 0.5 0.525 0.565 0.645 0.57 0.595 0.645 0.71 0.62 0.655 0.705 0.765

61 71 84 113 74 87 103 140 129 151 180 232 173 203 247 301 218 265 324 387

10 10 7 5.6 13 13 10 8 18 18 15 12 25 25 20 16 30 30 25 20

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

701 20140110

PORTABLE POWER CABLES

Item #

SOOW/SEOOW Control Cables Size/ Conductors

Strands

Nominal O.D. (in)

Weight /MFT (lb)

Ampacity

22220 22320 22420 22470 22221 22321 22421 22521 22222 22322 22422 22552 22223 22323 22423 22553

8/2 8/3 8/4 8/5 6/2 6/3 6/4 6/5 4/2 4/3 4/4 4/5 2/2 2/3 2/4 2/5

96/28 96/28 96/28 96/28 96/26 96/26 96/26 96/26 96/24 96/24 96/24 96/24 7x17/.0223 7x17/.0223 7x17/.0223 7x17/.0223

0.662 0.701 0.783 0.851 0.752 0.818 0.892 0.992 0.892 0.913 1.027 1.117 1.091 1.158 1.267 1.396

220 290 377 452 301 421 521 665 459 585 771 1029 665 940 1170 1419

40 40 35 28 55 45 45 36 70 70 60 48 95 95 80 64

PORTABLE POWER CABLES

Item #

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 701 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Welding Cable 600V ICEA Approved 105°C - 40°C Applications Designed for connections from electrode holders and clamps to arc welders, bus welding box or transformer. Recommended for use in shipyards, mines, and other areas where cable is subject to extreme physical abuse. Flame retardant, oil resistant, resilient, resists compression cuts and abrasion, durable handling. This cable is not suitable for in line voltage use. Improper use could be hazardous to personnel and could damage equipment. Construction • Conductor is annealed rope stranded bare copper conductor per ICEA S-75-381. • Insulation is Ethylene Propylene Rubber (EPR) type EP, Class 45, 105 C. Table 50.55 of UL.1581. • Operating Voltage: 600V max. Standards Meets ASTM B-3 ASTM B1732, ICEA S-175-381, IEC 254-1. Available on Request • Class M stranding • Colors • Hypalon or Neoprene Insulation • UL or CSA Listed • Custom Cut Lengths Notes • Nominal resistance of conductor acc to ICEA S-75-381 Class K Welding Machine Rating Lengths up to 13.7m 45ft Amps AWG mm2

Item #

W01-6 W02-4 W03-2 W04-1 W05-1/0 W06-2/0 W07-3/0 W08-4/0 W09-250 W10-350 W11-500

Lengths 14m to 30.5m 46ft to 100ft AWG mm2

Lengths 76.2m to 30.8m 101ft to 250ft AWG mm2

75

4

21

4

21

4

21

100

2

34

2

34

2

34

200

1

42

1

42

2/0

67

300

1/0

54

2/0

67

4/0

107

400

2/0

67

3/0

85





600

3/0

85

4/0

107





Size AWG

Nominal Stranding Class K

Nominal Resistance of Conductor /MFT@25°C (ohm)

Nominal Thickness of Insulation (in)

Nominal O.D. (in)

Copper Content /MFT (lb)

Weight /MFT (lb)

Amps

6 4 2 1 1/0 2/0 3/0 4/0 250MCM 350MCM 500MCM

285/30 412/30 647/30 817/30 1021/30 1289/30 1650/30 2065/30 2479/30 3416/30 4921/30

0.4190 0.2630 0.1670 0.1330 0.1050 0.0842 0.0668 0.0530 N/A N/A N/A

0.059 0.059 0.071 0.071 0.079 0.079 0.079 0.079 0.125 0.125 0.125

0.319 0.366 0.429 0.508 0.555 0.598 0.673 0.716 0.866 0.953 1.130

83 133 213 266 342 433 538 687 804 1120 1638

120 180 260 320 400 500 610 760 855 1255 1800

75 100 140 160 190 223 265 310 445 552 695

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

702 20180201

PORTABLE POWER CABLES

www.buyawg.com

PORTABLE POWER CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Type W Type RHH/RHW Single Conductor 90°C UL 600/2000V Applications For use as portable power systems, entertainment industry activities such as theatre, television, nightclubs, motion pictures, mobile communication vans, spotlights and sound permanent or temporary power. Permanent wiring of 600 volt power supplies, hoists, cranes and other applications where flexible power leads must be installed in conduit or raceways. Construction • Conductor is 8 — 500 MCM fully annealed stranded bare copper. • Insulation is premium grade 90°C EPDM. • Jacket is black CPE. • Jacket marking is TYPE W PORTABLE POWER CABLE (UL) DRY 90°C WET 75°C 2000V SUNLIGHT RESISTANT - P(#) MSHA-(SIZE)-TYPE RHH (UL) 600V. • Temperature range of -40°C to +90°C . • Voltage rating of 600 volt Type W. • Water and sunlight resistant. • Designed to withstand severe environmental conditions. • Withstands exposure to oil, acids, alkalies, heat, flame, moisture and chemicals. • Lengths cut to order. Standards • Meets or exceeds flame test requirements of MSHA, IEEE, ICEA, and UL • Conforms to ICEA S-61-658 • ICEA S-75-381 NEMA WC70 UL TYPE W and RHH or RHW-2 MSHA approved

Item #

Size AWG

Conductor Stranding

Nominal Thickness of Insulation (in)

Nominal Thickness of Insulation (mm)

Nominal O.D. (in)

Nominal O.D. (mm)

Current Amps

Net Weight /MFT

S-01-W8 S-02-W6 S-03-W4 S-04-W2 S-05-W1 S-06-W10 S-07-W20 S-08-W30 S-09-W40 S-10-W250 S-11-W350 S-12-W500

8 6 4 2 1 1/0 2/0 3/0 4/0 250 350 500

133 259 133 259 259 259 259 259 259 259 855 1235

0.06 0.06 0.06 0.06 0.08 0.08 0.08 0.08 0.08 0.095 0.095 0.095

1.52 1.52 1.52 1.52 2.03 2.03 2.03 2.03 2.03 2.41 2.41 2.41

0.450 0.530 0.585 0.630 0.745 0.780 0.845 0.910 0.970 1.035 1.130 1.300

11.93 13.46 14.86 16.00 18.92 19.81 21.46 23.11 24.64 26.29 28.72 33.02

83 109 145 192 223 258 298 345 400 445 552 695

140 205 275 365 475 555 675 805 965 1165 1520 2100

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

703 20140110

PORTABLE POWER CABLES

www.buyawg.com

PORTABLE POWER CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Type W 2-Conductor Magnet Crane Cable 600/2000V 90°C Applications Magnet Crane Cable is a heavy duty, portable cable that is designed especially to use on magnet cranes, and may be used on mobile mining equipment, lifting magnets, cutters, loaders, conveyers, drills or pumps where grounded circuits are not required, in portable power situations and as temporary power supply. Construction • Conductors are flexible stranded, annealed copper. • Insulation is Thermoset EPR. • Cabled with fillers for roundness with an open reinforced over assembly for mechanical protection. • Jacket is Thermoset CPE. Standards • Meets or exceeds flame test requirements of MSHA, IEEE, ICEA, and UL • Conforms to ICEA S-61-658 • ICEA S-75-381 NEMA WC-70 UL TYPE W and RHH or RHW-2 MSHA approved

Item #

MC1W-8 MC2W-6 MC3W-4 MC4W-2

No. of Conductors

Size AWG

Number of Strands

Insulation Thickness (mil)

Overall Diameter (in)

Net Weight /MFT. (lb)

2 2 2 2

8 6 4 2

133 259 259 259

.060 .060 .060 .060

.81 Inches .93 Inches 1.08 Inches 1.27 Inches

430 Lbs 590 Lbs 830 Lbs 970 Lbs

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

704 20140110

PORTABLE POWER CABLES

www.buyawg.com

PORTABLE POWER CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Type W Round Multi-Conductor 90°C UL 600/2000V Applications For use in heavy duty services as power supply cable, AC systems (grounded and ungrounded), mobile and portable electrical equipment, motor and battery leads. For 2 conductor cables use on DC or AC single phase systems where no grounding is required, or on DC systems with one conductor for grounding. For 4 conductor cables, use on two or three phase AC systems with one conductor used for grounding. For 5 conductor cables, use in applications where separating the system neutral from the frame ground is required. Construction • Conductor is 8 - 500 MCM fully annealed stranded bare copper. • Insulation is premium grade color coded 90°C EPDM. • Jacket is 90°C Black CPE+ with temperature range of -40°C to +90°C . • Jacket is indent printed for easy identification (successive footage printing available). • Jacket marking is TYPE W PORTABLE POWER CABLE 2000V 90°C DRY 75°C WET SUN RES (UL) PK(#) MSHA • Designed to withstand severe environmental conditions. • Withstands exposure to oil, acids, alkalies, heat, flame, moisture and chemicals. • Rope lay stranding for maximum flex life with excellent impact resistance and cable core bound for superior flexibility and toughness. • Suitable for continuous submersion in water. • Lengths cut to order. Standards ICEA S-75-381 NEMA WC-58 UL TYPE W and MSHA approved. Notes • These ampacities are based on a conductor temperature of 90°C and an ambient air temperature of 40°C per ICEA PUB-S-75-381 NEMA WC0-8. For ampacities per National Electrical Code requirements, refer to the latest NEC edition. • Shipping tolerance +/- 10% • Heavy duty neoprene jacket optional. • Successive footage printing available.

Item #

M01-2W8 M02-2W6 M03-2W4 M04-2W2 M05-2W1 M06-2W10 M07-2W20 M08-2W30 M09-2W40 M10-3W8 M11-3W6 M12-3W4 M13-3W2 M14-3W1 M15-3W10 M16-3W20 M17-3W30 M18-3W40

No. of Conductors

Size AWG

Conductor Stranding

Nominal Thickness of Insulation (in)

Nominal Thickness of Insulation (mm)

Nominal O.D. (in)

Nominal O.D. (mm)

Current Ampacity

Net Weight /MFT (lb)

2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3

8 6 4 2 1 1/0 2/0 3/0 4/0 8 6 4 2 1 1/0 2/0 3/0 4/0

133 259 259 259 259 259 259 259 259 133 259 259 259 259 259 259 259 259

0.060 0.060 0.060 0.060 0.080 0.080 0.080 0.080 0.080 0.060 0.060 0.060 0.060 0.080 0.080 0.080 0.080 0.080

1.52 1.52 1.52 1.52 2.03 2.03 2.03 2.03 2.03 1.52 1.52 1.52 1.52 2.03 2.03 2.03 2.03 2.03

0.790 0.910 1.060 1.250 1.440 1.520 1.650 1.770 1.920 0.955 1.010 1.150 1.320 1.490 1.650 1.750 1.890 2.040

20.07 23.11 26.92 31.75 36.58 38.81 41.92 44.96 48.77 24.26 25.65 29.21 33.53 37.85 41.92 44.45 48.01 51.82

72 95 127 167 191 217 250 386 328 59 79 104 138 161 186 215 249 287

365 510 700 1015 1490 1710 1880 2420 2490 530 660 925 1325 1600 2280 2680 3220 3900

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

705 20140110

PORTABLE POWER CABLES

www.buyawg.com

Type W Round Multi-Conductor 90°C UL 600/2000V Item #

PORTABLE POWER CABLES

M19-3W250 M20-3W350 M21-3W500 M22-4W8 M23-4W6 M24-4W4 M25-4W2 M26-4W1 M27-4W10 M28-4W20 M29-4W30 M30-4W40 M31-5W8 M32-5W6 M33-5W4 M34-5W2 M35-5W1 M36-5W10 M37-5W20 M38-5W30 M39-5W40

No. of Conductors

Size AWG

Conductor Stranding

Nominal Thickness of Insulation (in)

Nominal Thickness of Insulation (mm)

Nominal O.D. (in)

Nominal O.D. (mm)

Current Ampacity

Net Weight /MFT (lb)

3 3 3 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 5

250 350 500 8 6 4 2 1 1/0 2/0 3/0 4/0 8 6 4 2 1 1/0 2/0 3/0 4/0

327 855 1235 133 259 259 259 259 259 259 259 259 133 259 259 259 259 259 259 259 259

0.095 0.095 0.095 0.060 0.060 0.060 0.060 0.080 0.080 0.080 0.080 0.080 0.060 0.060 0.060 0.060 0.080 0.080 0.080 0.080 0.080

2.41 2.41 2.41 1.52 1.52 1.52 1.52 2.03 2.03 2.03 2.03 2.03 1.52 1.52 1.52 1.52 2.03 2.03 2.03 2.03 2.03

2.390 2.680 3.030 0.955 1.090 1.250 1.480 1.680 1.790 1.930 2.070 2.260 1.070 1.210 1.400 1.610 1.880 1.960 2.130 2.260 2.460

60.71 68.07 76.96 24.26 27.69 31.75 37.59 42.67 45.47 49.02 52.58 57.40 27.18 30.73 35.56 40.89 47.75 49.78 54.10 57.40 62.48

320 394 487 54 72 93 122 143 165 192 221 255 50 68 88 116 136 157 182 210 242

5070 6570 8700 620 825 1175 1650 2450 2570 3450 4050 4970 710 1010 1400 2340 3040 3460 4180 4900 5980

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 705 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Type G Round 90°C 600/2000V Applications For use in heavy duty services as power supply cable, mobile and portable electrical. For 2 conductor cables use with AC single phase systems where grounding is required. Construction • Conductor is 8 — 500 MCM fully annealed stranded bare copper. • Insulation is premium grade color coded 90°C EPR. • Withstands exposure to oil, acids, alkalies, heat, flame, moisture and chemicals. • Rope lay stranding for maximum flex life with excellent impact resistance and cable core bound for superior flexibillity and toughness. • Suitable for continuous submersion in water. • Jacket is 90°C Black CPE with temperature range of -40°C to +90°C . • Jacket is Indent printed for easy identification (successive footage printing available). • Jacket marking is (SIZE) TYPE G-GC portable power cable 600/200V 90°C sun oil resistant C(UL) FT-5 (-40°C) MSHA. • Lengths cut to order. Standards ICEA S-75-381 and MSHA approved. Notes • These ampacities are based on a conductor temperature of 90°C and an ambient air temperature of 40 °C per ICEA PUB-S-75-381 NEMA WC70. For ampacities per National Electrical Code requirements, refer to the latest NEC edition. • Shipping tolerance +/- 10% • Heavy duty neoprene jacket optional. • Succesive footage printing available.

Item #

2 Conductor 2-01-G8 2-02-G6 2-03-G4 2-04-G2 2-05-G1 2-07-G20 2-08-G30 2-09-G40 2-6-0G10

No. of Conductors

Size AWG

Conductor Stranding

Grounding Conductor Size AWG

2 2 2 2 2 2 2 2 2

8 6 4 2 1 2/0 3/0 4/0 1/0

133 259 259 259 259 259 259 259 259

2 # 10 2 # 10 2#8 2#6 2#5 2#3 2#2 2#1 2#4

Ground Check Size AWG

Nominal Nominal Thickness of Thickness of Insulation Insulation (in) (mm) 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06 0.06

1.52 1.52 1.52 1.52 2.03 2.03 2.03 2.03 2.03

Nominal O.D. (in)

Nominal O.D. (mm)

Current Ampacity

Net Weight /MFT (lb)

0.81 0.93 1.08 1.27 1.44 1.65 1.77 1.92 1.52

20.57 23.62 27.43 32.26 36.58 41.91 44.96 48.77 38.61

72 95 127 167 191 250 286 328 217

495 650 940 1360 1730 2240 2860 3500 2000

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

706 20140110

PORTABLE POWER CABLES

www.buyawg.com

Type G Round 90°C 600/2000V Item #

PORTABLE POWER CABLES

3 Conductor 3-01-G8 3-02-G6 3-03-G4 3-04-G2 3-05-G1 3-06-G10 3-07-G20 3-08-G30 3-09-G40 3-10-G250 3-11-G350 3-12-G500 4 Conductor 4-01-G8 4-02-G6 4-03-G4 4-04-G2 4-05-G1 4-06-G10 4-07-G20 4-08-G30 4-09-G40

No. of Conductors

Size AWG

Conductor Stranding

Grounding Conductor Size AWG

Ground Check Size AWG

3 3 3 3 3 3 3 3 3 3 3 3

8 6 4 2 1 1/0 2/0 3/0 4/0 250 350 500

133 259 259 259 259 259 259 259 259 627 855 1235

2 # 10 2 # 10 2#8 2#7 2#6 2#5 2#4 2#3 2#2 2#2 2 # 1/0 2 # 2/0

10 10 10 10 8 8 8 8 8 8 8 8

4 4 4 4 4 4 4 4 4

8 6 4 2 1 1/0 2/0 3/0 4/0

133 259 259 259 259 259 259 259 259

4 # 12 4 # 12 4 # 10 4#9 4#8 4#7 4#6 4#5 4#4

Nominal Nominal Thickness of Thickness of Insulation Insulation (in) (mm)

Nominal O.D. (in)

Nominal O.D. (mm)

Current Ampacity

Net Weight /MFT (lb)

0.060 0.060 0.060 0.060 0.080 0.080 0.080 0.080 0.080 0.095 0.095 0.095

1.52 1.52 1.52 1.52 2.03 2.03 2.03 2.03 2.03 2.41 2.41 2.41

0.965 1.050 1.165 1.340 1.510 1.650 1.750 1.890 2.040 2.390 2.680 3.030

24.51 26.67 29.59 34.04 38.35 41.91 44.45 48.01 51.82 60.71 68.07 76.96

59 79 104 138 161 186 215 249 287 320 394 487

665 830 1145 1485 2100 2550 3020 3660 4410 6060 7400 10100

0.06 0.06 0.06 0.06 0.08 0.08 0.08 0.08 0.08

1.52 1.52 1.52 1.52 2.03 2.03 2.03 2.03 2.03

0.970 1.110 1.245 1.470 1.680 1.790 1.930 2.070 2.260

24.64 28.19 31.62 37.34 42.67 45.47 49.02 52.58 57.40

54 72 93 122 143 165 192 221 255

635 900 1280 2000 2660 3140 3780 4500 5520

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 706 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Type MP-GC 3-Conductor EPR or XLP 5kV-15kV 100% Insulation Level (Grounded) 90°C Applications This cable is designed for high voltage connections between power distribution systems in mines, mine tunnels, shafts, and mine load centers where continuous monitoring of the ground system is required. This cable is suitable for installation in Ducts, troughs, tray or direct burial for nonflexing service. Construction • Conductor is stranded annealed copper enveloped in a strand shield. • Insulation is Ethylene Proplylene Rubber (EPR) or Cross Linked Polyethylene (XLPE). • Assembly is semi-conducting tape and a metallic tape shield with grounding conductors consisting of two bare grounds and one 8-gauge insulated ground check that are cabled together in the interstices of the power conductors and fillers are added to make round. • A single faced rubber filled tape is applied overlapped. • 5kV and 8kV jacket is Chlorinated Polyethylene (CPE). • 15kV jacket is Polychloride (PVC); Jacket options include Chlorinated Polyethelene (CPE or Hypalon (SCSPE). Standards Conforms to ICEA S-75-381 NEMA WC70 Notes Shipping tolerance +/- 10%

Item #

Power Conductors Number of Strands

Power Conductors Insulation Thickness (in)

Ground Wire Size AWG

Ground Wire Number of Strands

Jacket Thickness (in)

Overall Diameter (in)

Net Weight /MFT (lb)

4 2 1/0 2/0 4/0 250 350 500

7 7 19 19 19 37 37 37

.090 .090 .090 .090 .090 .090 .090 .090

7 5 3 2 1/0 1/0 2/0 4/0

7 7 7 7 19 19 s 19 19

1.32 1.45 1.63 1.75 2.00 2.13 2.35 2.64

.110 .110 .110 .140 .140 .140 .140 .170

1240 1670 2300 2730 3490 4620 5940 8160

4 2 1 1/0 2/0 4/0 250 350 500

7 7 19 19 19 19 37 37 37

0.115 0.115 0.115 0.115 0.115 0.115 0.115 0.115 0.115

8 6 5 4 3 1/0 2/0 3/0 4/0

7 7 7 7 7 19 19 19 19

0.11 0.11 0.11 0.11 0.14 0.14 0.14 0.14 0.14

1.43 1.55 1.65 1.75 1.88 2.12 2.25 2.46 2.75

1440 1760 2070 2440 2940 4130 4760 6090 8360

2 1/0 2/0 4/0 250 350 500

7 19 19 19 37 37 37

0.175 0.175 0.175 0.175 0.175 0.175 0.175

6 4 3 1 1/0 2/0 4/0

7 7 7 7 19 19 19

0.19 0.14 0.14 0.14 0.14 0.14 0.14

1.88 2.05 2.15 2.4 2.5 2.75 3.1

2190 2890 3350 4610 4990 6380 8770

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

707 20140110

PORTABLE POWER CABLES

5kV CPE MP5-01-4 MP5-02-2 MP5-03-1/0 MP5-04-2/0 MP5-05-4/0 MP5-06-250 MP5-07-350 MP5-08-500 8kV CPE MP8-01-4 MP8-02-2 MP8-03-1 MP8-04-1/0 MP8-05-2/0 MP8-06-4/0 MP8-07-250 MP8-08-350 MP8-09-500 15kV PVC MP15-01-2 MP15-02-1/0 MP15-03-2/0 MP15-04-4/0 MP15-05-250 MP15-06-350 MP15-01-500

Power Conductors Size AWG

PORTABLE POWER CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

SHD-GC 3-Conductor EPR/CPE 2kV 100% Insulation Level – 90°C Applications This cable is designed for heavy duty high voltage portable power trailing cable between the load center and equipment such as power shovels, draglines, and other excavators and is suitable for use in open pit mines, quarries and on gantry cranes where the delivery of a heavy power load and maximum safety is required. Construction • Conductor is extra flexible, stranded, tinned annealed copper. • Insulation is Ethylene Propylene Rubber (EPR). • Covered grounding and 8-gauge ground check conductors. • Jacket is Black Chlorinated Polyethylene (CPE). Standards Conforms to ICEA S-75-381 NEMA WC70 Notes • Neoprene jacket optional. • Shipping tolerance +/- 10%

Item #

Power Conductors Size AWG

Power Conductors Number of Strands

Power Conductors Insulation Thickness (in)

Ground Wire Size AWG

Ground Wire Number of Strands

Jacket Thickness (in)

Overall Diameter (in)

Net Weight /MFT (lb)

6 4 2 1/0 2/0 4/0 250 350 500

133 133 259 266 342 532 427 427 427

.110 .110 .110 .110 .110 .110 .120 .120 .120

10 8 6 4 2 1 1/0 2/0 4/0

49 133 133 133 133 259 259 259 259

.185 .185 .205 .220 .220 .235 .250 .265 .280

1.56 1.68 1.87 2.08 2.20 2.50 2.69 2.95 3.31

1460 1690 2290 3110 3570 4990 5820 7540 9840

2kV DL01-5-6 DL05-5-4 DL03-5-5 DL04-5-1/0 DL05-5-5/0 DL06-5-4/0 DL07-5-550 DL08-5-350 DL09-5-500

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

708 20140110

PORTABLE POWER CABLES

www.buyawg.com

Type SHD-GC 3-Conductor EPR/CPE 2kV 100% Insulation Level – 90°C Item #

Power Conductors Size AWG

Power Conductors Number of Strands

Power Conductors Insulation Thickness (in)

Ground Wire Size AWG

Ground Wire Number of Strands

Jacket Thickness (in)

Overall Diameter (in)

Net Weight /MFT (lb)

6 4 2 1/0 2/0 4/0 250 350 500

133 133 259 266 342 532 427 427 427

.070 .070 .070 .080 .080 .080 .095 .095 .095

10 8 6 4 2 1 1/0 2/0 4/0

19 133 133 133 133 133 133 133 259

.155 .155 .170 .190 .250 .220 .220 .235 .265

4 2 1/0 2/0 4/0 250 350 500

133 133 259 259 259 427 427 427

150 150 150 150 150 150 150 150

8 6 4 3 1 1/0 2/0 4/0

49 133 133 133 133 259 259 250

.205 .220 .220 .235 .250 .250 .280 .295

1.94 2.12 2.32 2.46 2.75 2.89 3.20 3.56

2240 2730 3380 4030 5440 6280 8300 12000

2 1/0 2/0 4/0

133 259 259 259

210 210 210 210

6 4 3 1

133 133 133 259

.235 .250 .250 .265

2.41 2.64 2.73 3.05

2950 3650 4250 5930

1/0 2/0 4/0

259 259 259

295 295 295

4 3 1

133 133 259

.265 .280 .295

3.05 3.20 3.50

5250 6000 7710

5kV

PORTABLE POWER CABLES

DL01-2-6 DL02-2-4 DL03-2-2 DL04-2-1/0 DL05-2-2/0 DL06-2-4/0 DL07-2-250 DL08-2-350 DL09-2-500 8kV DL01-8-4 DL02-8-2 DL03-8-1/0 DL04-8-2/0 DL05-8-4/0 DL06-8-250 DL07-8-350 DL01-8-500 15kV DL01-15-2 DL02-15-1/0 DL03-15-2/0 DL04-15-4/0 25kV DL02-25-2/0 DL03-25-4/0 DL04-25-250

960 1410 1940 2950 3470 4800 5950 7400 10100

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] 708 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Type DLO Diesel Locomotive Cable 600/2000V 90°C Applications This cable is for wiring down tower applications and may be used on electrically driven, earth moving equipment, as power supply to A.C. welding equipment, as water heater leads, and in motor and power lead applications. May be installed in wet or dry areas, conduit, ducts, trays or troughs. Construction • Conductor is extra flexible tinned, stranded copper with a separator layer. • EPR insulation. • Jacket is CPE (Hypalon jacket available upon request). Standards • Meets flame test requirements of MSHA and passes ICEA cold bend test at -40°C. • Meets AAR specifications. • UL listed as RHH-RHW-2. • Rated for CT use, 1/0 and larger. Notes • Ampacity based on single conductor in free air, 90°C conductor temperature, 40°C ambient per ICEAS-75-381. • Sequential footage marks. • Shipping tolerance +/- 10%

Item #

Area Circular (mil)

Size AWG

Number of Strands in Conductor

Insulation Thickness (in)

Jacket Thickness (mil)

Overall Diameter (in)

Net Weight /MFT (lb)

Ampacity 1/C Free Air 90°C

DL-600/2-1 DL-600/2-2 DL-600/2-3 DL-600/2-4 DL-600/2-5 DL-600/2-6 DL-600/2-7 DL-600/2-8 DL-600/2-9 DL-600/2-10 DL-600/2-11 DL-600/2-12 DL-600/2-13 DL-600/2-14 DL-600/2-15 DL-600/2-16 DL-600/2-17 DL-600/2-18 DL-600/2-19 DL-600/2-20 DL-600/2-21 DL-600/2-22

3831 6088 10910 14950 24640 36760 42420 60600 90900 111100 131300 181800 222200 262600 313100 373700 444400 535300 646400 777700 929200 1111000

14 12 10 8 6 5 4 2 1 1/0 2/0 3/0 4/0 262.6 313.1 373.7 444.4 535.3 646.4 777.7 929.2 1111.0

19 19 27 37 61 91 105 150 225 275 325 450 550 650 775 925 1100 1325 1591 1924 2299 2745

.045 .045 .045 .060 .060 .060 .060 .060 .080 .080 .080 .080 .080 .090 .090 .090 .090 .110 .110 .110 .110 .110

30 30 30 30 30 30 30 30 45 45 45 45 45 65 65 65 65 65 65 65 65 65

.24 .25 .29 .33 .40 .43 .45 .50 .64 .69 .73 .80 .86 .97 1.01 1.11 1.18 1.29 1.38 1.47 1.58 1.74

34 45 68 82 125 175 195 265 425 500 570 780 890 1100 1280 1500 1760 2110 2410 2930 3450 4130

32 36 55 83 109 127 145 192 223 258 298 345 400 458 514 574 642 725 815 910 1025 1143

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

709 20140110

PORTABLE POWER CABLES

www.buyawg.com

PORTABLE POWER CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Jumper Cable Transformer Lead Wire Non-Shielded 5kV/15kV 90°C Applications This cable is for use as flexible power leads permitting temporary connections or bypassing energized power lines at voltages up through 15kV, phase to phase. Installation These cables must be positioned away from contact with grounds, transformer cases, cross-arms, etc. to avoid possible high stress and capacitance leakage due to the fact that jumper cables cannot be protected against prolonged contact with other conductors or grounds by shielding. Construction • Conductor is flexible stranded copper conductor with a semi-conducting strand shield covering. • Insulation is Ethylene Propylene Rubber (EPR). • Jacket is heavy duty, red NBR/PVC jacket. • Rating is 5KV/15KV, 90°C. • Non-Shielded Standards • ICEA S-75-381 NEMA WC70

Item #

Size AWG

Number of Strands

Overall Diameter (in)

J1-5/15-2 J2-5/15-10 J3-5/15-20 J4-5/15-40 J5-5/15-350 J6-5/15-500

2 1/0 2/0 4/0 350 500

259 259 259 516 855 1235

0.900 0.985 1.040 1.165 1.416 1.580

Net Weight /MFT (lb) 550 730 850 1174 2220 2377

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

710 20140110

PORTABLE POWER CABLES

www.buyawg.com

PORTABLE POWER CABLES

NOTES

www.buyawg.com TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

APPENDIX Table of Contents Terms & Conditions/Warranty ..................................................................................................A Wire & Cable: Handling and Installation Engineering Guide ................................................H Jacket Material Selection Chart................................................................................................K Insulation Performance Specifications: EPR & TRXLPE .........................................................O Allowable Ampacities of Insulated Conductors .....................................................................N Thermal Resistivity of Materials .............................................................................................M PowerGuard® Testing Recommendations............................................................................321 Wire & Cable: Methods of Color Coding & Color Coding Charts ..........................................B Recommended Reel Handling Practices..................................................................................C Steel Reel Specifications & General Purpose Steel Fluted Returnable Reels ......................D Cabling.........................................................................................................................................I Metric Size to AWG Size............................................................................................................E Copper Conductor Stranding Chart: Class A thru M ..............................................................G Wire & Cable: Glossary of Terms ..............................................................................................F

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

000 20170306

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

NOTES

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Terms & Conditions Warranty Price Prices are based on COMEX copper or LME aluminum listed on the quotation. Prices are subject to copper/aluminum adjustment at the time of shipment in the event that COMEX or LME copper exceeds the quoted base in excess of 10%. Cancellation Cancellation after acceptance of an order cannot be made without Seller’s written consent and on such conditions as will indemnify Seller against loss for commitments made and work already complete and/or in process. Special Orders When Special Make Orders are accepted the entire order must be taken. Special Make Orders cannot be cancelled or modified once accepted and cannot be returned. Tolerances Non-Stock & Special Make merchandise is subject to the following tolerances: Total product -0 and Reel lengths +/-10%, or as specified. Exact reel lengths will incur additional charges. Delivery Any shipment schedule is approximate. Seller shall not be liable for any delay in delivery or failure to deliver caused in whole or in part by any reason beyond Seller’s control. Claims Buyer agrees to inspect merchandise for defects and for conformity, and agrees to check material against shipping papers upon unloading at destination. All claims for shortages or defective merchandise must be made by Buyer in writing within seven (7) days of receipt of shipment. Returns Return merchandise must be full reels or cartons, undamaged and in the original unopened package. Credit will be given for returned merchandise only for full reels of undamaged wire if still in the original package. No merchandise may be returned without the written authority of Seller and receipt of Seller’s RMA number. No merchandise may be returned after the expiration of sixty (60) days following the date of shipment. Returns may be subject to a Restocking Fee. Non-Stock & Special Make merchandise will not be considered for return and is not subject to the previous stated return conditions. Refunds No cash refunds. Trade Credit Only. All returns and other proper claims for credit may be applied toward future purchases only or as agreed. Taxes Liability for all taxes imposed by any government authority with respect to the goods herein ordered shall be assumed and paid by Buyer. Modifications Any modification of these Standard Terms and Conditions shall not be binding on Seller unless signed on behalf of Seller by a representative authorized to do so, regardless of whether Seller has commenced shipping of any merchandise ordered hereunder or whether Seller has accepted payments therefore.

Warranty All merchandise ordered will be supplied in accordance with the description on the face of the order acknowledgment and in accordance with applicable specifications and design standards, and will be substantially free from defects in material and workmanship. The Seller’s liability in respect to any defect in or failure of the merchandise supplied, as well as any loss, injury or damage attributable thereto, is limited to the replacement or repair of defects which, under proper use and handling, have been proven to the Seller’s satisfaction to arise solely from faulty design, materials or workmanship, within a period of one (1) year from the date of shipment from the Seller’s factory. Further, the Seller must be notified in writing of the said defect or failure within a period of one (1) year from the date of shipment. The replacement of such merchandise does not include expenses incurred in the installation or use of the material. No merchandise shall be returned to the Seller’s factory or warehouse for credit or replacement before the Seller has officially advised of this transaction. Warranty Limitations This warranty does not cover the repair or replacement of any cable which fails as a result of damage in transit, misuse, neglect, accident, Acts of God, abuse, improper handling, improper storage, excessive stress, faulty or improper or unauthorized installation or repair, negligent maintenance or failure to comply with the written instructions for installation, use or maintenance provided by the Seller. Exclusion of Other Warranties This warranty is in lieu of all other warranties, express or implied, and all other warranties, including but not limited to the implied warranties of merchantability and fitness for a particular purpose, are expressly disclaimed. Limitation of Liability and Limitation of Actions In no event shall Seller be liable for any indirect, incidental, special, punitive or consequential loss, damage or expense (which shall be deemed to include without limitation: any loss of profit or revenue, loss of goodwill, loss claimed by end-user’s customers, or loss of business opportunity) of any nature or kind, however arising, whether in contract, in tort or otherwise, even if Seller is deemed to be aware of the possibility of such damages. Seller’s maximum liability for any claim, loss or damage shall not exceed the purchase price for the cable subject to a claim under any circumstance, even if end-user has claims or is subject to claims in excess of this limitation. Any legal proceeding related to this warranty must be presented within (1) year after the cause of action arises. Sole and Exclusive Remedy This document sets forth the Seller’s sole and exclusive warranty obligation to the Buyer and the Buyer’s sole and exclusive remedy in the event of defective cable. Choice of Law The laws of the State of Florida, without giving effect to its conflicts of law principles, govern all matters arising out of or relating to these Standard Terms and Conditions and all the transactions it contemplates, including, without limitation, its validity, interpretation, construction, performance and enforcement.

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

A 20140110

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

NOTES

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Wire & Cable: Handling and Installation Engineering Guide Receiving and Handling Cable .............................................H1 Receipt of Cable Reels ..........................................................H1 1. Visually check for shipment damage............................H1 2. Inspect reel tags .............................................................H1 3. Check dimensional tolerances ......................................H1 Handling of Cable Reels........................................................H1 Storage of Cable Reels ......................................................H2 Installation Suggestions .......................................................H2 Safety Measures Prior to Pulling Cable ...........................H2 Temperature Considerations.........................................H2 Duct Sizing......................................................................H2 Jam Ratio........................................................................H2 Cable Clearance .............................................................H3 Minimum Bending Radius (Static Conditions) ............H3 Minimum Bending Radius (Dynamic Conditions).......H3 Cable Training (Offset Bending) ....................................H3 Power and Control Cables without Metallic Shielding or Armor.H4 Power and Control Cables with Metallic Shielding or Armor ......H4 Clearing Ducts ................................................................H4 Trench for Direct Burial..................................................H4 Rack/Trays .......................................................................H4 Precautions During Cable Pulling .................................H4 Cable Guides ..................................................................H4 Cable Lubricant ..............................................................H5 Pulling Eyes & Grips ......................................................H5 Maximum Pulling Tensions ...........................................H5 A. Pulling Eye..............................................................H5 B. Cable grips..............................................................H6 Sidewall Bearing Pressure (Static Conditions) ............H6 Sidewall Bearing Pressure (Dynamic Conditions).......H7 Special Conditions for Metallic Armored Cables................H7 Sheath Currents and Voltages in Single Conductor Cables......H7 Eliminating Sheath Currents.............................................H7 Standing Voltage................................................................H8 Installation of Single Conductor Cables in Parallel ............H8 Reel Capacities...................................................................H8 NEMA Method................................................................H8 Handling of Cables Reels......................................................H9 Shipment for Unloading with a Forklift at Dock................H10 Shipment for Unloading down an Inclined Ramp ............H10 Shipment for Unloading with a Forklift at Jobsite............H10 Unloading from Open Flat Bed Trailers..............................H11 Cable Reel Handling............................................................H12 Excavating, Trenching, Backfilling, and Surface Restoration...........................................................................H13

Receiving and Handling Cable In order to benefit from investing in underground cable (power cable), the purchaser should put into practice a complete visual inspection program that will help identify any cable that is damaged during shipment. If any cable is undesirable, it is then returned to the manufacturer instead of being installed. By recognizing and refusing damaged cable, one can considerably improve the dependability of the underground system.

Receipt of Cable Reels Once the purchaser has received the cable shipments, they should carry out an approval inspection. A cable approval inspection involves some straightforward and low-cost steps that can yield significant dividends. The following steps should be taken to insure proper acceptance of cable: 1. Visually check for shipment damage Visually check cable reels for any damage that may have taken place during delivery. The purchaser should be mainly worried for cable damage if: a. A reel is laying flat on its side, especially if it is a large conductor size, such as 500 kcm, 750 kcm, or 1,000 kcm b. Numerous reels are piled on top of each other c. Other cargo is piled on the reel d. Nails have been driven into the overhang to prevent overcrowding e. A reel overhang is broken f. A cable covering is detached, discolored, or broken g. A cable end seal is detached or broken (a broken or absent end seal means that moisture may have come into the cable) h. A reel has fallen (concealed damage likely) 2. Inspect reel tags Visually check each reel to assure that it has the correct tags and labels as noted in the specifications. The reel should contain the subsequent minimum information: a. Purchaser’s name and address b. Purchase order number c. Conductor size and type d. Insulation thickness and type e. Jacket type f. Quantity of cable on reel g. Beginning and ending sequential footage numbers present on the jacket Confirm that the cable description, reel size, and cable footage are equivalent to that specified. Any missing information should be acquired from the manufacturer. 3. Check dimensional tolerances Make a straightforward measurement of the cable dimensions on one reel of each size of cable in a shipment to prove that the cable’s dimensions meet the requirement.

Handling of Cable Reels To guarantee that material handling equipment does not touch or interfere with cable surfaces or with protective covering on the reel, the utmost care should be taken when moving the cable reels. It is very important that cable reels not be dropped from any height, or be allowed to roll unrestrained. Cable reels should be moved or lifted using the technique depicted at the end of this document.

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

H1 20170208

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Wire & Cable: Handling and Installation Engineering Guide 1. For cranes, booms, or other overhead lifting equipment, a sturdy steel arbor or heavy rod or pipe should be placed in through the reel hubs so that the cable reel can be lifted by slings that make the most of spreader bars. This technique will assure that sling pressure against a reel flange, slanting of the reel, sliding of the sling, and other unstable situation will be reduced. 2. When lifting reels by fork truck type equipment, reels should only be lifted from the sides, and only if the blades of the fork truck are long enough to support both flanges. This way will make sure that the lift pressure is uniformly dispersed on both flanges and not on the cable itself. 3. Rolling reels containing cables should be kept to a minimum; if rolling is necessary, reels should always be rolled in the direction indicated by the “arrows” on the sides of the reel flanges or in the opposite direction to which the cable is wrapped onto the reel. Rolling the reels this way will avoid the release of the cable wraps, which may lead to problems during installation. 4. It is important that any debris be cleared from the path over which the cable reels are to be rolled since that might damage the cable if the reels were to roll over it. Cable reels should be rolled in the direction of the “Roll This Way” arrow and lowered in a controlled manner. The ramps should be spaced far enough apart so that they are touching the reel flanges at all times. Storage of Cable Reels Cable reels should not be stored on their sides if at all possible. To prevent deterioration of the reels and moisture seeping into the cables, it is preferable to store cable reels indoors on a hard, dry surface. If cable reels are stored outdoors they must be supported off the ground and protected with a suitable weatherproof material. The reel supports should be at least twice the width of the reel flange, long enough to provide a sufficient load bearing surface (to prevent sinking), and high enough to prevent the reel from sitting in free standing water in case of rain. Reel supports should be placed under each reel flange, and to prevent rolling each reel should be placed between the reel flange and the support at opposite sides of the flange. All cable reels should be stored in such a way so as to allow easy access for lifting and moving, away from construction activities, falling or lying objects, sources of high heat, open flames, chemicals or petroleum products, etc. that may cause damage to the cable. It is also recommended to use fences or any other suitable barriers to protect cables and reels against damage by vehicles or other moving equipment in the storage area. If the cable is stored on reels for future use after the factory applied end caps are removed, the exposed cable ends MUST be re-sealed using properly applied weatherproof end caps or by taping the ends with a tape designed to prevent moisture. PVC tapes or Duct Tape are not appropriate for preventing moisture. One must secure the loose ends of the cable reels to the reel flange and cannot lie on the ground. Reels and end caps should be inspected from time to time if they will be stored outside for a long period of time. A once a month inspection is suitable at first but one should consider increasing this if storage time is extended since wooden reels tend to deteriorate over time and sealed end caps will lose their usefulness. Rates of deterioration will vary depending on the environment in which the reels are stored.

NOTE: If a specific method of shipping is used, such as shipping to a job site, etc., the manufacturer must be notified of these special requirements.

Installation Suggestions Below you will find a general guide for the installation of shielded and unshielded cables, jacketed cables rated 600 to 35,000 volts in conduit, underground ducts, racks, trays or direct buried. Safety Measures Prior to Pulling Cable Temperature Considerations It is important to consider that low temperatures create handling and pulling difficulties of varying degrees, depending on cable construction and installation location. Most cables can be safely handled if not subjected to temperatures lower than -10°C (14°F) in the twenty-four (24) hour period prior to pulling and bending the cable. If temperatures do fall below these values during the following 24 hour period, measures should be taken to transport the cable to a warm storage area. The cable should be exposed to a temperature of 15°C (60°F) for 24 hours to ensure warm-up. Pulling eyes, if necessary, should be set up. If the cable is installed during cold weather conditions, cable should be pulled more slowly and trained in place the same day it is removed from the warm storage area. The cable should also not be dropped or bent if cold outside. Duct Sizing Select duct size in such a way that the difference between the hoop diameter of the cable(s) and the inside diameter of the duct will not be less than ½”. Also check that the cross-sectional area of the cable is not more than the percentage of the interior cross-sectional area of the conduit, as recommended by the National Electric Code (NEC). In addition, consider using larger ducts or additional pull boxes if long pulls are required. Jam Ratio Jamming might occur in bends if three cables are pulled in parallel in duct. This happens when the cables adjust from a triangular pattern to a cradled pattern as they are pulled in through the bend. This pattern change will force the two outer cables to move farther apart. The cables will also jam if the conduit diameter is too small to contain the wider pattern. To prevent this, the jam ratio should be checked. The jam ratio corresponds to the inside diameter of the duct to the cable diameter, such that:

J=D÷d Where: J = Jam ratio D = Inside diameter of duct (in) d = Outside diameter of cable (in) The proper cable configuration can be determined if the above jam ratio is calculated. The likely configurations are as follows: Jam Ratio Cable Configuration J < 2.4 Triangular 2.4 < J < 2.6 More likely triangular 2.6 < J < 2.8 Either triangular or cradled 2.8 < J < 3.0 More likely cradled J > 3.0 Cradled

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] H2 20170208

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Wire & Cable: Handling and Installation Engineering Guide Cable jamming tends to occur between J = 2.8 and J = 3.1. This is true if the sidewall bearing pressure (SWBP) in a bend surpasses the 1,000 lbs/foot. Cable Clearance In order to make sure that the cables can be pulled through the conduit, specifically in applications where the National Electric Code (NEC) limits on conduit fill do not apply, one needs to calculate the clearance between the cable(s) and conduit. The recommended calculated clearance should not be less than 0.5 inches. However, a lesser clearance, such as 0.25 inches, may be suitable for primarily straight pulls. In addition, the clearance should contain the pulling eye or cable grip, which is used for the cable pull. The formulas below can be used to calculate the cable clearance for a single cable pull and for a three-cable pull. (Please Note: To allow for differences in cable and duct dimensions and ovality of the duct at bends, the nominal cable diameter “d” has been increased by 5%). a. Single Cable Pull

C = D – 1.05 x d b. Three Cable Pull (triangular pattern)

(D – 1.05 x d) D C = __ – 1.366 (1.05 x d) + ____________ x 2 2

calculating conduit or tubing fill. The actual dimensions of the equipment grounding or bonding conductor (insulated or bare) shall be used in the calculation.” The below formula can be used when a calculation must be made to comply with the NEC fill ratio requirements:

FR = [NPC x (PCD ÷ 2)2 + NGC x (GCD ÷ 2)2] ÷ (CD ÷ 2)2 Where: FR = Fill Ratio (%) NPC = Number of Phase Conductors with the same diameter PCD = Diameter of Phase Conductor (in) NGC = Number of Ground Conductors with the same diameter GCD = Diameter of Ground Conductor (in) CD = Diameter of Conduit or Duct (in) Minimum Bending Radius (Static Conditions) The following formula can be used to determine the minimum values for the radii to which such cables may be bent for permanent training:

MBR = OD x M 1–

[

1.05 x d ____________ (D – 1.05 x d)

]

2

Where: C = Cable clearance (in) D = Inside diameter of duct (in) d = Outside diameter of cable (in) Please reference the following table in dealing with applications where the National Electric Code (NEC) is compulsory. The table shows the most ordinary scenarios concerning the fill ratio of many cable configurations in various duct sizes. Conductor Fill Per NEC Code Duct 1 Conductor 2 Conductors 3 Conductors 4 conductors Sizes (53% Fill Ratio) (31% Fill Ratio) (40% Fill Ratio) (40% Fill Ratio) (in) Area Dmax Area Dmax Area Dmax Area Dmax (in2) (in) (in2) (in) (in2) (in) (in2) (in) ½ 0.16 0.453 0.09 0.245 0.12 0.227 0.12 0.197 ¾ 0.28 0.6 0.16 0.324 0.21 0.301 0.21 0.261 1 0.46 0.764 0.27 0.413 0.34 0.383 0.34 0.332 1¼ 0.80 1.005 0.47 0.543 0.60 0.504 0.60 0.436 1½ 1.08 1.172 0.63 0.634 0.82 0.588 0.82 0.509 2 1.78 1.505 1.04 0.814 1.34 0.755 1.34 0.654 2½ 2.54 1.797 1.48 0.972 1.92 0.902 1.92 0.781 3 3.91 2.234 2.26 1.208 2.95 1.12 2.95 0.97 3½ 5.25 2.583 3.07 1.397 3.96 1.296 3.96 1.122 4 6.74 2.931 3.94 1.585 5.09 1.47 5.09 1.273 5 10.60 3.674 6.20 1.987 8.00 1.843 8.00 1.596 6 15.31 4.415 8.96 2.388 11.56 2.215 11.56 1.918 Please Note: “dmax(in)” is the maximum single conductor diameter that will comply with the above requirements. “Area (in2)” is the area of the conductor(s). Ground wires have not been considered in the above table. The NEC requires that “Equipment grounding or bonding conductors, where installed, shall be included when

Where: MBR = Minimum radius of bend (in) OD = Outside diameter of cable (in) M = Diameter multiplier (Please see tables on the next page(s)) Note: The above calculation applies to STATIC conditions ONLY. Please reference the DYNAMIC conditions section below and the Sidewall Bearing Pressure section for the minimum bending radius of cable in motion. Minimum Bending Radius (Dynamic Conditions) The following formula can be used to determine the minimum values for the radii to which such cables may be bent while being pulled into an installation and while under tension. This value will largely depend on the tension the cable experiences as it exits the bend. The greater the exiting tension, the greater the minimumbending radius will be for the cable.

MBR = (Te ÷ SWBP) X 12 (in) Where: MBR = Minimum radius of bend (in) Te = Tension as cable exits the bend (pounds x force) SWBP = Maximum allowable Sidewall Bearing Pressure (pounds x force per foot of bend radius) Cable Training (Offset bending) You may use the following formula to determine the minimum distance necessary for permanent cable training (offset bending) in a manhole:

L = S (4 R – S) Where: L = Minimum distance required (in) S = Offset (in) R = Bending radius to cable centerline (in)

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

H3 20170208

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Wire & Cable: Handling and Installation Engineering Guide

S

*For conductor sizes 1500kcm and larger, the minimum bending radius for LC Shielded cable is 18X the cable diameter.

Note 1: Multiply the diameter of the cable by the factor in the table above to attain the minimum-bending radius. Note 2: These limits may not be appropriate for use with conduit bends, sheaves or other curved surfaces around which the cable may be pulled under tension while being installed due to sidewall bearing pressure limits. The minimum radius specified refers to the inner radius of the cable bend and not to the axis of the cable.

L R

Allow a suitable length of straight cable at both ends of the offset bend.

Clearing Ducts Using a plug that is roughly the same diameter as the inside of the duct does not permit obstructions in the duct since it pulls the plug through the structure. After doing this, use a wire brush to clean and remove foreign matter from the duct. In order to prevent scratch damage to the cable jacket during pulling, it is important to smooth the interior.

Power and Control Cables without Metallic Shielding or Armor Insulation Thickness (mil) 155 and less 156 to 310 310 and over

Overall Diameter of Cable (in) 1.000 and Less 1.001 to 2.000 2.001 and Over Minimum Bending Radius as a Multiple of Cable Diameter 4 5 6 5 6 7 — 7 8

Note 1: The highest applicable multiplier should be used in all cases. The calculated minimum bend radius (applicable multiplier x outside diameter of cable) refers to the inner surface of the bent cable, and not the axis (centerline) of the cable conduit. Note 2: Use the thickest of the insulations of the cables within the assembly and the diameter of the largest single cable within the cable assembly to determine the multiplier. Afterwards, apply that multiplier to the diameter of the overall assembly. Note 3: The minimum values for the radii to which cables may be bent during installation may not apply to conduit bends, sheaves or other curved surfaces around which the cable may be pulled under tension while being installed. Larger radii bends may be required for such conditions. (Please reference “Precautions during Cable Pulling” in the “Sidewall Bearing Pressure” section).

Power and Control Cables with Metallic Shielding or Armor Cable Type

Minimum Bending Radius Minimum Bending Radius For Single Conductors For Multiple Conductors† Interlocked and Polymeric Armor (without shielded conductor) 7 7 Interlocked Armor and Polymeric Armor (with shielded conductor) 12 7 Wired Armored Cable 12 12 Metallic Tape Shielded Cable 12 7 Metallic Fine Wire Shield 12 7 Concentric Neutral Wire Shielded Cable 8 5 Lead Sheath Cable 12 7 LC Shielded Cable 12* 7 † Use the larger of the two minimum bending radii when considering the minimum-bending radius for multiple conductors.

Trench for Direct Burial To prevent damage to the cable jacket during or after cable installation, the trench should be clean of sharp stone, glass, metal or wood debris. The trench bottom should be evenly covered with a layer of soil or sand that has been screened through a medium-tofine mesh screen to remove all larger stones or other material. This will assure a smooth, soft-bedding surface for the cable(s). It is a good idea to lay a protective covering on the fill about 6-8 inches above the cable to protect it if working in an urban area or near where a lot of digging occurs. If working under highways or railroad rights-of-way, it is also a good idea to install the cable in a pipe or conduit to give added mechanical protection. Rack/Trays One should check the entire path that the cable will follow during pulling to make sure that the cable will have a smooth ride, free of all barriers or sharp edges. In checking this, one should consider the position the cable will take on when under tension. Precautions During Cable Pulling Cable Guides All guides should be in the form of large diameter, smooth-surfaced, free-turning sheaves or rollers to prevent damage to the cable jacket when guiding the cable from the reel to the duct mouth or trench. Guide tubes or chutes must be smooth, burr-free working surfaces with the largest possible bend radii and be securely anchored if used. Mounting the cable reel in sturdy jacks, leveling the reel shaft and lubricating the reel arbor holes with grease will lead to low cable tension. If breaking the reel needs to happen, it should only be done to prevent reel over-run when the pull is slowed or stopped, or on steep downhill runs where cable weight is enough to overcome cable-duct friction. This information also applies for rack or tray installations. The following points should be noted when making such pulls: 1. Cable support rollers should be spaced close enough so that the cable’s normal sag, even when under tension, will not result in tray dragging. 2. The cable rollers should be contoured so that the cable will not ride off the end of the roller or be “pinched” into a sheave contour diameter that is smaller than that of the cable. 3. When rollers or sheaves are used to guide the cable through the bends, it is important that enough of them be used to guide the

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] H4 20170208

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Wire & Cable: Handling and Installation Engineering Guide cable in a smooth curve of the desired radius from tangent point to tangent point. If this is not done, the cable may be “kinked” around the radius of each roller. The cable may be paid off the reel and laid into the trench as the reel is moved along the length of the trench in cases of direct-burial installations. When this happens, the cable is laid on a bed of soil or sand. If the cable needs to be pulled through the trench, the best way to do so is to support the cable on temporary rollers so that the cable does not drag over the soil or sand bed. If one does not have rollers handy, sacks filled with very fine sand or other fine powdery material may be used as an alternative to support the cable and keep it from dragging on the trench bed during the pulling process. Cable Lubricant To reduce pulling tensions and damage on cables, lubricants may be used in conduit. When using cable or pulling lubricants, one should avoid compounds that may contain oils or greases since they may damage the cable jackets. Also, pulling lubricants that contain micro-spheres or micro-balls should be avoided for medium-voltage cable installations. These kinds of lubricants are meant to be used on low-tension pulls that are not representative of power cable pulls. Most commercially available pulling lubricants can be used with little worry for compatibility. But, one does need to keep in mind that some pulling lubricants react poorly to some cable jacket compounds, which may lead to ruining the cable jacket. It is best to avoid damage to the cable jacket by consulting the cable manufacturer regarding lubricant compatibility with specific jacket compounds. Pulling Eyes & Grips Pulling eyes attached to the cable conductor(s) are used for large, heavy cable, or for cables where the pulls are very long or contain numerous bends. To use the pulling eye, one must fasten it directly to the conductor(s) on the end of the cable by soldering the copper conductors into a socket-type eye, or by mechanically compressing the aluminum conductors into an aluminum eye. Then, a tape seal or heat-shrinkable tube is placed over the eye-cable joint to provide a reliable weather-tight seal for the cable during pulling. For armored cables, the armor needs to be properly secured to the eye to insure the reliability of the cable during pulling. Generally, pulling eyes tend to be installed at the factory; however, they can also be installed in the field. Often times, woven wire pulling grips, generally called “baskets” are used to pull armored cables; they are well suited for pulling smaller size voltage cables, or where the pulls are fairly short. Special measures need to be taken if using “baskets” on Interlock Armored cables to avoid damage to the cable or problems in making the pull. The puling grip may tend to stretch the armor if the grip is not properly secured to the cable. The following method for preparing the cable and attaching the grip is advised: 1. Select the grip size that fits the cable diameter or armor best. Determine the length of the gripping portion of the grip. 2. Find two points on the end of the cable. The first is 75% of the grip length from the end; the second is 100% of the grip length from the end. 3. Get rid of the sheath/armor, and also the outer jacket if there, to the first mark. Do not damage the core of the armor. If need be,

secure the armor at the cut point with friction tape before cutting. 4. Apply four, 3-inch long, tight wrappings of friction tape. Place this tape on a) the end of the core, b) on the core to the edge of the sheath/armor, c) on the jacket, or sheath/armor to the edge of same, and d) on jacket, or sheath/armor where the last 3 inches of grip will be. 5. If cable will be exposed to moisture during the pull, seal the cut ends of the conductors with sealing mastic and vinyl tape, or heat-shrinkable cap(s). 6. Place the grip on the cable and secure it tightly by “milking” it from the cable end towards the end of the grip. 7. Clamp the back end of the grip to secure it to the cable with a steel hose clamp, such as the “Band-It” types, or a tough steel wire that is firmly applied. 8. Over the clamp apply a tape wrapping to smooth it and prevent drag during the pull. CAUTION: The ends of cable pulled this way will not be entirely safe from water. If this is an issue, properly applied pulling eyes should be used. *NOTE: The force applied by pulling a grip may damage or disrupt the underlying cable, so it is best to cut off the section immediately below the grip as well as the three feet of cable behind the grip before fixing together. Maximum Pulling Tensions To prevent damage to the cable, pulling tensions for installing electrical cables should be maintained as low as possible. This may be done through proper use of size ducts or conduits, by avoiding long pulls, and avoiding runs that may contain sharp bends or severe changes in elevation. The following maximum allowable pulling tension must not be passed when pulling cable by the method indicated. A. Pulling Eye The maximum tension for cables pulled with a pulling eye should not exceed the value calculated using the following formula:

Tmax = CTC x CA x N Where: Tmax = Maximum pulling tension (lb) CA = Conductor Area (cmil) N = Number of conductors being pulled CTC = Conductor Tension Constant For CTC with aluminum compression eyes or blots use: 0.011 — Copper conductor 0.008 — Aluminum Stranded conductor 0.006 — Aluminum Solid conductor For CTC with filled eyes or bolts use: 0.013 — Copper conductor 0.011 — Aluminum Stranded conductor 0.008 — Aluminum Solid conductor NOTE: When calculating the maximum pulling tension, DO NOT consider the area of neutral or grounding conductors in cable(s). The number of conductors should be reduced by one (1) when cal-

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

H5 20150116

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Wire & Cable: Handling and Installation Engineering Guide culating the maximum tension for parallel cable assemblies. The “N” can equal the number of cables in the assembly, excluding ground wires. This number can also be reduced by one (1) as an extra measure. Pulling Eye Maximum Pulling Tension (lbs) Size Copper 1/C 3-1/C 3-1/C Single Parallel Triplex 8 AWG 181 362 543 7 AWG 229 458 687 6 AWG 288 576 864 5 AWG 363 726 1089 4 AWG 459 918 1377 3 AWG 578 1156 1734 2 AWG 729 1458 2187 1 AWG 920 1840 2760 1/0 AWG 1161 2322 3483 2/0 AWG 1464 2928 4392 3/0 AWG 1845 3690 5535 4/0 AWG 2327 4654 6981 250 kcm 2750 5500 8250 300 kcm 3300 6600 9900 350 kcm 3850 7700 11550 400 kcm 4400 8800 13200 450 kcm 4950 9900 14850 500 kcm 5500 11000 16000 550 kcm 6050 12100 18150 600 kcm 6600 13200 19800 650 kcm 7150 14300 21450 700 kcm 7700 15400 23100 750 kcm 8250 16500 24750 800 kcm 8800 17600 26400 900 kcm 9900 19800 29700 1000 kcm 11000 22000 33000

Stranded Aluminum 1/C 3-1/C 3-1/C Single Parallel Triplex 132 264 396 166 332 498 209 418 627 264 528 792 333 666 999 420 840 1260 530 1060 1590 669 1338 2007 844 1688 2532 1064 2128 3192 1342 2684 4026 1692 3384 5076 2000 4000 6000 2400 4800 7200 2800 5600 8400 3200 6400 9600 3600 7200 10800 4000 8000 12000 4400 8800 13200 4800 9600 14400 5200 10400 15600 5600 11200 16800 6000 12000 18000 6400 12800 19200 7200 14400 21600 8000 16000 24000

B. Cable Grips When using a cable grip to pull cables, the maximum tension should not exceed the value shown in the following two tables, or the formula used in the table above. Pulling Grips Maximum Pulling Tension (lbs) Type of Cable PE, XLP Insulated EPR Insulated Single Multiple Single Multiple Cable Cables Cable Cables Unshielded, with or without Jacket 2000 2000 2000 2000 Concentric Wire URD with Jacket 10000 5000 10000 10000 Concentric Wire URD without Jacket 10000 5000 6000 3000 Taped Shielded with Jacket 10000 5000 10000 10000 Fine Wire Shielded with Jacket 10000 5000 10000 10000 LC Shielded with Jacket 8000 4000 5000 2500 Polymeric Armored Cables (See Note 3) — — 10000 10000 Interlock Armor with PVC Jacket 5000† — 5000† — Interlock Armor with Poly Jacket 5000† — 5000† — Lead Sheathed Cables See Subsequent Table

† Interlock Armor pulling tension using pulling grips should be limited to the lesser of the value provided above or 50% of value of Tmax calculated using “Pulling Eye” formula.

Note 1: The above tensions correspond to three cables in one grip. The stress on the cable conductor should not exceed 16,000 psi (0.013 lbs/cmil) for annealed copper conductors when using a grip. For stranded ¾ and full hard aluminum conductors the stress should not exceed 14,000 psi (0.011 lbs/cmil) and 10,000 psi (0.008 lbs/cmil) for solid ½ to full hard aluminum conductors. The allowable conductor stress should be based on two cables sharing a load for three single conductor cables in parallel and triplexed configurations. Note 2: The manufacturer of the cable(s) used should be contacted to determine the mechanical limitations of the cable(s). Note 3: It is recommended that pulling grips be used during installation of Polymeric Armored Cables, due to their higher sidewall bearing pressure capabilities. Pulling Grips Maximum Pulling Tension (psi) Type of Cable PE, XLP Insulated EPR Insulated Single Multiple Single Multiple Cable Cables Cable Cables Lead Shielded 16000 16000 8000 8000 (Note 4)

(Note 4)

(Note 5)

(Note 5)

Paper Insulated Single Multiple Cable Cables 1500 1500 (Note 6)

(Note 6)

Note 4: The maximum pulling tension stress limit for pulling grips on lead sheathed cable with XMPLE/TRXLPE insulation is 16,000 psi of lead sheath area for a single cable as well as one grip on three cables (per AEIC CG5-2005). Note 5: The maximum pulling tension stress limit for pulling grips on lead sheathed cable with EPR insulation is 8,000 psi of lead sheath area for a single cable as well as one grip on three cable (per AEIC CG5-2005). Note 6: The maximum pulling tension stress limit for pulling grips on lead sheathed cable with Paper insulation is 1,500 psi of lead sheath area for a single cable as well as one grip on three cables (per IPCEA P-41-412-1958). Sidewall Bearing Pressure (Static Conditions) The dynamic radial pressure of cable which is pulled around a bend under pulling tension should be kept as low as possible and not exceed the following values listed in the table. To calculate these values use the following formula:

PSW = Te ÷ Br Where: PSW = Sidewall Bearing Pressure in pounds per foot of bend radius Te = Pulling Tension as cable exits the bend (lbs)* Br = Bend radius, in feet *Note: The maximum pulling tension determined by the above formulas must be observed.

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] H6 20170208

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Wire & Cable: Handling and Installation Engineering Guide Sidewall Bearing Pressure (Dynamic Conditions) To calculate the minimum bending radii for dynamic conditions, use the following formula:

MBR = (Te ÷ PSW) x 12 Where: MBR = Minimum Bending Radius (in) Te = Pulling Tension as cable exits the bend (lbs)* PSW = Maximum Sidewall Bearing Pressure in pounds per foot of bend radius from following table *Note: The maximum pulling tension determined by the above formulas must be observed. Sidewall Bearing Pressure (lbs/ft of bend radius)* Type of Cable PE, XLP EPR Insulated Insulated Unshielded, without Jacket 1200 500 Unshielded, with Jacket 1200 1000 Interlock Armor with PVC Jacket Single Conductor & Three Conductor having round core (100% fillers) 800 800 Interlock Armor with Poly Jacket Single Conductor & Three Conductor having round core (100% fillers) 1000 1000 Concentric Wire URD, without Jacket 1200† 1000† Concentric Wire, Encapsulating Jacket 2000 2000 Concentric Wire, with Sleeved Jacket 1500 1500 LC Shielded with Jacket 1500 1500 Taped Shielded with Jacket 1500 1500 Fine Wire Shielded with Jacket 1500 1500 Teck-90 Cable, Single Conductor & Three Conductor having round core (100% fillers) 800 800 Teck-90 Cable, Three Conductor with minimal or no fillers 350 350 Lead Sheathed (Solid Dielectric) 2000** 2000** Polymeric Armored Cables Air Bag® 2400 AirGuard® 3000 Lead Sheath (PILC) 400 † Value shown corresponds to a single conductor cable pull. Maximum Sidewall Bearing Pressure limits of 750 and 200 lbs. per foot, respectively, are recommended for a three-conductor pull. * For a pulling eye/pulling grip, the maximum pulling tension must be observed in addition to the maximum sidewall bearing pressure limit. ** These values are based on the cross-sectional area of one lead sheath.

Note 1: It is recommended that the manufacturer of the cable(s) in question be contacted concerning the mechanical limitations of the cable.

Special Conditions for Metallic Armored Cables Sheath Currents and Voltages in Single Conductor Cables A voltage is induced in the concentrically applied wires of the grounding conductor and the armor in a single conductor cable with an interlocking armor. A current will flow in the completed path if the armor and the con-

centric grounding conductor are bonded or grounded at more than one (1) point. The magnitude of the induced voltage is relative to the magnitude of the current in the phase conductor. The magnitude of the sheath currents is a function of the induced voltage and the sheath impedance. The armor and the grounding conductor can become very hot if the sheath current is large. If this occurs, the conductor insulation will also be subjected to temperatures that may cause electrical failure or reduce the life expectancy of the cable. One will have to derate the cable if sheath currents are large enough to raise the temperature of the insulation above its rated value. In a single conductor cable carrying currents less than 180 amps, sheath currents will not pose a problem since induced voltages and sheath impedances minimize sheath losses. In single conductor cables carrying currents between 180 and 425 amps, sheath currents will not pose a problem if the cables are spaced about one (1) cable diameter apart. When this spacing is done, mutual heating is minimized and the induced voltage is reduced by virtue of field cancellation. In single conductor cables carrying currents larger than 425 amps, it is normally necessary to derate the cables to avoid overheating unless the sheath currents are removed. Armor of magnetic material (such as galvanized steel) should not be used on single conductor cables intended for use in AC circuits. Eliminating Sheath Currents One needs to make sure that all paths by which sheath currents circulate are kept open in order to prevent the current from flowing. One should ground and bond cable armors and concentrically applied grounding conductors at the supply end only and afterwards isolated from ground and each other. Isolation may be established when installing cables in individual ducts by using cables with PVC jackets or other insulating materials, or also by mounting cables. No sheath current will flow if the armors and concentrically applied grounding conductors are bonded and grounded at the supply end through a non-ferrous metal panel and mounted on an insulated panel at the load end. For an illustration of this, please see the figure down below. a) Cables enter supply end enclosure through metallic non-ferrous panel to avoid overheating. Cable armors are bonded through panel. b) Cable enters load end enclosure through panel of insulating material. The insulating material maintains the open circuit of the armors. c) Cable armors and concentrically applied grounding conductors are bonded and grounded at the supply end only. When installed in this way, the armor and concentric grounding conductor do not form a part of the system ground circuit and a separate ground conductor should be installed, following the proper electrical code. d) All cable connectors and lock nuts are made of non-magnetic metal (aluminum or other).

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

H7 20170208

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Wire & Cable: Handling and Installation Engineering Guide Standing Voltage An induced voltage will exist between ground and both the armor and the concentric grounding conductor throughout the length of the cable when single conductor cables are installed, as shown in the figure below:

Installation of Single Conductor Cables in Parallel

LOAD END

SUPPLY END

Non-Ferrous Metal Panel

Panel of Insulating Materials

Connectors & Locknuts of Non-Ferrous Material

Separate Ground Conductor Metal Enclosure

Metallic Shield Cut-Off Inside Enclosure Close to Connector

The magnitude of this voltage is proportional to the phase conductor current, the cable length and the spacing between the cables. The magnitude of the “standing voltage” is usually limited to about 25 volts. Please be aware that some Electrical Inspection Authorities limit this voltage to a lower amount. By grounding the armor and the concentric grounding conductor at the midpoint of the cable run, one can limit the standing voltage and also increase the circuit length. If doing this, the cable must go through a junction box at the midpoint of the run and must be connected on each side of the junction box as shown on the supply end of the figure above. In this case, the cables at both the supply and load ends must be connected through panels of insulating material to prevent the flow of sheath currents. Nevertheless, when two (2) or more single conductor cables are installed in parallel per phase, grounding at the midpoint is not allowed. For more on installing single conductor armor cables in parallel please see the diagram below, which depicts symmetrical configurations:

Notes: 1. S = Separation of groups. This equals the width of one group. 2. Horizontal and vertical separation between adjacent cables should be a minimum of one (1) cable diameter to benefit from the ampacity in free air in a ventilated cable tray. 3. Neutral conductors can be located outside of the above groups. Reel Capacities NEMA Method The formula for calculating footage capacities of reels for round cable is shown below. A 5% factor and 95% traverse utilization have been built into the formula. Cables must be wound evenly to obtain consistency.

{[ (

]}

f 0.95 x C * A–2xX–B * A – 2 x X – B * ________ F = __ B + ____________ 0.95 x D ____________ 1.9 – D 12 1.9 – D D

)

][

][

* Round off the result to the nearest whole number.

Where: F = Feet of cable on reel A = Flange diameter, in inches B = Drum diameter, in inches C = Inside traverse, in inches D = Cable diameter, in inches X = This variable is defined as the distance between the cable and the outside edge of the reel flange. Clearance is equivalent to 1 inch or 1 cable diameter, whichever is the larger quantity. Note: The NEMA formula does not cover paralleled or triplexed assemblies. Contact the cable manufacturer for the maximum footages of these assemblies.

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] H8 20170208

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Wire & Cable: Handling and Installation Engineering Guide Handling of Cables Reels

YES

NO

Reels should be lifted with a shaft extending through both flanges.

Inspect all reels. Reels laying flat should be refused or received subject to inspection.

Reels should be lowered using hydraulic gate, hoise or forklift. LOWER CAREFULLY.

Do NOT allow forks to touch cable or reel wrap.

Load with flanges on edge and chock securely..

Never drop reels from trailer.

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

H9 0140401

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Wire & Cable: Handling and Installation Engineering Guide Shipment for unloading with a forklift at dock

Shipment for unloading down an inclined ramp

Shipment for unloading with a forklift at jobsite

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] H10 20170208

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Wire & Cable: Handling and Installation Engineering Guide Unloading from Open Flat Bed Trailers Spacer Bar

CORRECT

Reel Tongs

INCORRECT

Winch Line

INCORRECT

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

H11 20170208

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Wire & Cable: Handling and Installation Engineering Guide Cable Reel Handling

Do NOT allow forks to touch cable or reel wrap.

Do NOT allow forks to touch cable or reel wrap.

Do NOT allow forks to touch cable or reel wrap. This method OK for Low Voltage Cable only!

Do NOT allow forks to touch cable or reel wrap.

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] H12 20170208

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Wire & Cable: Handling and Installation Engineering Guide Excavating, Trenching, Backfilling, and Surface Restoration PRODUCTS Excavated Backfill Materials • Backfill shall be free of roots, stumps, rubbish, and stone, concrete and clay lumps larger than one-third cubic foot. • Remove and dispose of unsuitable material in backfill. EXECUTION Preparation • Verify location of existing underground utilities. • Protect all existing underground facilities. • Protect all existing above ground facilities and structures. • Provide for continuance of use of all utilities. Trenching • Cut existing surfaces to expose area for trenching. • Bore below all asphalt surfaces. • No classification of excavated material will be made. • Strip topsoil and stockpile for replacement/restoration • Excavate trench to required line and grade. • Keep trench width to a minimum to allow proper jointing of utility and compaction of bedding and backfill. • Organize operations to keep time of open trench to a minimum. • Excavation by blasting will not be allowed. • Trench bottom shall be firm for entire length and width. • Remove unstable material from trench bottom and replace with approved bedding. • Remove rock, shale and hardpan to one foot below bedding elevation and replace with approved foundation material. • Keep trenches free from water. • Dispose of excavated material not used or suitable for use as backfill. • Stabilize unstable trench walls. • Protect bottom of trench from frost. Do not place structures or conduit on frozen ground. Backfilling and Compacting • Do not start encasement backfilling until work which will be covered is completed and areas are free of foreign material. • Restore underground facilities interfered with to original condition. • Place minimum of two feet of backfill over initial encasement before beginning compaction operations. • Compaction by flooding will not be allowed. • Level depressions in finished trench. • Replace topsoil. • Backfill compaction - 85% of standard proctor density unless otherwise specified on drawings. ° Testing fees will be paid by the Contractor.

Drain Tile Repairs Contractor shall use good engineering and construction practices to minimize damage to existing drainage tiles and waterways in order to minimize damage to existing drainage. Contractor shall consult with landowners to determine locations of existing tiles, if known, prior to construction. In the event that Contractor damages drainage tiles or waterways during construction, Contractor shall repair or replace the damaged tiles and restore the damaged waterways, either at their original location or at such other location as will accomplish their original purpose. Suitable fill material shall be placed under the repaired or replaced tile to minimize settling. Contractor shall coordinate drainage tile repair such that Landowner’s representative may observe such work by Contractor, provided such representative must be available in accordance with Grantee’s construction schedule. All underground power lines (including ground cables) shall be installed at least 4 feet below finished ground elevation. During construction, if Contractor encounters underground drainage tiles while trenching for underground lines, Contractor shall install underground lines below the drainage tiles unless the drainage tiles are 6 feet or more below the surface, in which case the underground lines shall be installed above the drainage tiles. Upon Completion of the work, Contractor shall provide a site map showing the “as built” location of the underground transmission lines on the Property. TESTING Backfill Compaction Test Compaction tests shall be performed at a depth of one and 1.5 feet above the cables and 3 feet above the cables. Compaction tests shall be performed every 500 feet for the first mile and every mile thereafter. Care is to be taken when compacting under, alongside, and immediately above the cable to avoid crushing the insulation and to preserve the trefoil configuration of the cable. Compaction Test Failure If the required state of compaction is not obtained, it shall be the responsibility of the Contractor to re-compact or rework the material to the required state of compaction. In cases where there is a failure to achieve the required state of compaction it may be required that the backfill be removed and re-compacted or replaced at the discretion of Engineer and/or Owner.

Surface Restoration • Provide surface restoration to match existing conditions.

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

H13 20180201

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

NOTES

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Jacket Material Selection Chart

Mechanical Abrasion Resistance Tensile Strength Elongation Compression Resistance Flexibility Environmental Flame Fresh Water Salt Water Motor Oil Fuel Oil Crude Oil Creosote Gasoline Kerosene Isopropyl Alcohol Wood Alcohol Grain Alcohol Sulfuric Acid Nitric Acid Hydrochloric Acid Sodium Hydroxide (Lye) Potassium Hydroxide (Potash) Calcium Hydroxide (Lime) Acetone Methyl Ethyl Ketone (MEK) Ethyl Acetate Lacquer Thinner Chloroform Carbon Tetrachloride Methyl Chloride General Leaves protective residue after combustion Oxygen index (ASTMD-2863) Halogen content - % weight Minimum installation temperature Dimensional stability underheat Maximum operating temperature

PVC

Polyethylene

Neoprene

Chlorosulphonated Polyethylene

Thermoplastic CP

Good Excellent Good Good Good

Excellent Excellent Excellent Excellent Fair

Good Excellent Excellent Excellent Excellent

Good Excellent Excellent Excellent Excellent

Excellent Good Good Good Fair

Good Good Good Good Good Good Poor Good Good

Excellent Excellent Excellent Good Good Good Fair Poor

Excellent Excellent Excellent Good Good Good Fair Poor

Fair Fair Fair Excellent Excellent Excellent Good Good Good Poor Poor Poor Poor Poor Poor Poor

Poor Exceptional Exceptional Excellent Slight swelling above 60°C Slight swelling above 60°C Good Excellent Slight swelling at higher temperature Good Good Good Excellent Excellent Excellent Excellent Excellent Excellent Excellent Good Good Good Good Good Poor

Poor Fair Fair Fair Excellent Excellent Excellent Good Good Poor Poor Poor Poor Poor Poor Poor Poor

Poor Good Good Good Excellent Excellent Excellent Excellent Excellent Fair Fair Fair Fair Fair Fair Fair Poor

Good Excellent Excellent Good Poor above 110°C Poor above 110°C Good Excellent Slight swelling at higher temperature Good Good Good Excellent Excellent Excellent Excellent Excellent Excellent Good Good Good Good Good Good Poor

Yes 23-30% 26 -10°C Fair 75°C

No 17-18% 0 -40°C Fair 75°C

Yes 31-39% 18 -20°C Excellent 90°C

Yes 30-36% 14 -20°C Excellent 90°C

Yes 30-34% 18-20 -40°C Fair 75°C

Note: When cables are to be installed in cold weather, they should be kept in heated storage for at least 24 hrs. before installation.

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

K 20150309

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

NOTES

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Insulation Performance Specifications EPR Performance Specifications The insulation shall be a premium quality, heat, moisture, ozone and corona resistanthermosetting ethylene propylene; TYPE I, II or III as listed in ICEA S-93-639 or ICEA S-97-682. The cable manufacturer shall compound the insulation material with in its own or remotely owned facilities. The insulation shall be compatible with both the conductor shield and the insulation shield. The thickness shall be at the 100% or 133% level as applicable and in accordance with the latest edition of ICEA. S-93-639, ICEA S-97-682 and UL 1072. The diameters over the insulation shall be in accordance with ICEA S-97-682. The EPR insulation shall also meet the guaranteed values as listed in the table below. PHYSICAL REQUIREMENTS Unaged

GUARANTEED VALUE 1600 275

Tensile strength, psi, min. Elongation at rupture, %, min. Tensile Stress at 200% elongation, psi, min. at room temperature 1000 Modulus, psi, min. @ 130°C 300 After Air Oven Aging at 121°C for 7 days (168 hours) Tensile stress, % of unaged value, min. 90 Elongation at rupture, % of unaged value, min. 90 Hot Creep Test at 150°C Elongation, %, max. 25 Set, %, max. 5 Heat Distortion after 1 hour in air oven at 121°C Percent max. 8.5 Ozone Resistance 0.030% Concentration, 25°C, 24 hours No Cracks No Cracks 0.0005% Concentration, 52°C, 24 hours No Cracks Cold Bend -55°C No Cracks Heat Deformation Test per ASTM D2220 % Max. Distortion of buffed samples of insulation conditioned for 5 minutes and under load for 15 minutes No Cracks

TRXLPE Performance Specifications Suitable for use for the following specifications • AEIC CS8 • ICEA S-94-649 • ICEA T-31-610 • ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable • UL 1072 MV-90 or MV-105 • CSA Standard C68.5-07 ICEA T-34-664 as applicable for TRXLPE insulated concentric neutral cable must conform to the following chart: PHYSICAL PROPERTIES

UNIT

TEST METHOD

VALUE

Density (Base Resin)

g/cm3

ASTM D1505

0.921

Tensile Strength

kg/ cm

ASTM D638

200

Elongation Oven Aging @ 135°C , 7 days

% ASTM

D638

550

Tensile Strength Retention

% ASTM

D638

> 90

Elongation Retention

% ASTM

D638

> 90

2

Hot/Set @ 200°C, 20N/cm2

IEC-60811-2-1

Hot Elongation

%

Permanent Set

%

Cure Behavior @ 180°C (MDR)

< 100 1

Tc90

minute

4.5

Moisture

ppm

HCY-I-24205

< 200

ELECTRICAL PROPERTIES

UNIT

TEST METHOD

VALUE

-

ASTM D150

< 2.3

Dielectric Constant @ 1 MHz Dissipation Factor @ 1 MHz

-

ASTM D150

< 0.0005

Dielectric Strength

kV/mm

ASTM D149

> 20

DC Volume Resistivity

ohm cm

ASTM D257

> 1016

UNIT

TEST METHOD

VALUE

%

Internal

< 15

%

Internal

< 0.1

TREE RESISTANCE Relative Bow-tie Tree Size Resistance to Water Tree Growth @25°C, 30 days

1. Tree test conditions: Frequency=1kHz, Applied Voltage=5kV, 0.01M NaCl Solution. 2. Values are typical : not to be construed for specification.

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

0 20170208

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

NOTES

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Allowable Ampacities of Insulated Conductors Allowable Ampacities of Insulated Copper Conductors

Allowable Ampacities of Insulated Aluminum or CopperClad Aluminum Conductors • Rated Up to and Including 2000 Volts, 60°C through 90°C (140°F through 194°F). • Not More Than Three CurrentCarrying Conductors in Raceway, Cable, or Earth (Directly Buried). • Based on Ambient Temperature of 30°C (86°F) .

• Rated Up to and Including 2000 Volts, 60°C through 90°C (140°F through 194°F). • Not More Than Three CurrentCarrying Conductors in Raceway, Cable, or Earth (Directly Buried). • Based on Ambient Temperature of 30°C (86°F). .

Conductor Size (AWG/kcmil)

Conductor ] Size (AWG/kcmil)

18 16 14* 12* 10* 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 700 750 800 900 1000

60°C/140°F TW, UF

75°C/167°F RHW, THHW, THW, THWN, XHHW, USE, ZW

15 25 35 40 55 65 75 85 100 115 130 150 170 195 210 225 260 285 315 320 330 355 375

20 30 40 50 65 75 90 100 120 135 155 180 205 230 250 270 310 340 375 385 395 425 445

90°C/194°F TBS, SA, SIS, FEP, FEPB, MI, RHH, RHW-2, THHN, XHH, XHHW, XHHW-S, USE-2, ZW 25 35 45 55 75 85 100 115 135 150 175 205 230 260 280 305 350 385 425 435 445 480 500

* Small Conductors. Unless specifically permitted in 240.4(E) through (G), the overcurrent protection shall not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper; or 15 amperes for 12 AWG and 25 amperes for 10 AWG aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied.

18 16 14* 12* 10* 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 700 750 800 900 1000

60°C/140°F TW, UF

75°C/167°F RHW, THHW, THW, THWN, XHHW, USE, ZW

15 20 30 40 55 70 85 95 110 125 145 165 195 215 240 260 280 320 350 385 400 410 435 455

20 25 35 50 65 85 100 115 130 150 175 200 230 255 285 310 335 380 420 460 475 490 520 545

90°C/194°F TBS, SA, SIS, FEP, FEPB, MI, RHH, RHW-2, THHN, XHH, XHHW, XHHW-S, USE-2, ZW

25 30 40 55 75 95 115 130 145 170 195 225 260 290 320 350 380 430 475 520 535 555 585 615

* Small Conductors. Unless specifically permitted in 240.4(E) through (G), the overcurrent protection shall not exceed 15 amperes for 14 AWG, 20 amperes for 12 AWG, and 30 amperes for 10 AWG copper; or 15 amperes for 12 AWG and 25 amperes for 10 AWG aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied.

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

N 20170208

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

NOTES

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Thermal Resistivities of Materials Material Insulating Materials* Paper insulation in solid type cables Paper insulation in oil-filled cables Paper insulation in cables with external gas pressure Paper insulation in cables with internal gas pressure A) Pre-impregnated B) Mass-impregnated PE XLPE PPL Polyvinyl chloride Up to and including 3kV cables Greater than 3kV cables EPR Up to and including 3kV cables Greater than 3kV cables Butyl rubber Rubber Protective Coverings Compounded jute and fibrous materials Rubber sandwich protection Polychoroprene PVC Up to and including 35kV cables Greater than 35kV cables PVC/Bitumen on corrugated aluminum sheaths PE Materials for Duct Installations Concrete Fibre Earthenware PVC PE

Thermal Resistivity (ρT) Km/W 6.0 5.0 5.5 5.5 6.0 3.5 3.5 5.5 5.0 6.0 3.5 5.0 5.0 5.0 6.0 6.0

5.0 6.0 6.0 3.5 1.0 4.8 1.2 6.0 3.5

*For the purposes of current rating calculations, the semiconducting screening materials are assumed to have the same thermal properties as the adjacent dielectric materials. Where plastic or elastomeric materials are used for protective coverings, the thermal resistivities shall be taken to be the same as those for the insulation grades of the materials given in this table.

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

M 20160322

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

NOTES

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

PowerGuard® Testing Recommendations June 7, 2016 Regarding field testing cables for commissioning, we recommend the VLF Testing in Accordance to IEEE 400: IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems in accordance to Table 1 IEEE400.2 VLF Test Voltage Levels for Sinusoidal, Cosine-Rectangular. Voltage Peak values are shown in brackets for Cosine-Rectangular and Squarewave. The most important application part of the new IEEE400.2 cable testing guide is the Table 1 below that shows the recommended VLF Hipot voltage testing levels for the various medium voltage cable ratings for both new (Acceptance and Installation Testing) and old (Maintenance Testing) cable installations. This is a Pass/Fail type test, the cable either withstands the specified test voltage or it does not. The IEEE400 defines types of field tests: Installation Test This test is conducted after the installation of the cable but before the installation ofaccessories like the splices and terminations. Its purpose is to detect any transport, manufacturing, storage or installation defects. Acceptance Test This test is performed after the installation of the accessories, but before energization ofthe cable. It checks for installation defects of the complete cable system, as well as defects as a result of shipping, manufacturing or storage. Test Frequency VLF test frequency is 0.1Hz of a testing of 30 minutes.

Cable Rating phase to phase (RMS) kV rms 5 8 15 25 35

Installation Test phase to ground

Acceptance Test phase to ground

Maintenance Test phase to ground

kV rms (or peak) 9 (13) 11 (16) 18 (25) 27 (38) 39 (55)

kV rms (or peak) 10 (14) 13 (18) 20 (28) 31 (44) 44 (62)

kV rms (or peak) 7 (10) 10 (14) 16 (22) 23 (33) 33 (47)

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

321 20170306

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

NOTES

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Wire & Cable Methods of Color Coding Used to identify conductors for point-to-point wiring and for circuit diagrams. Color codes are used to establish a standard for use by different manufacturers. The first color code used colored tracers in a solid colored braid. Most control cable color codes are adaptations of this method. Later, for ease and convenience, ink printed versions were developed. Telephone requirements established special color codes. Color Codes (ICEA Methods) ICEA/NEMA Method 1 Colored insulation with contrasting ink tracers as required. Six different insulation colors and four different colored ink tracers are used to provide positive identification through 21 conductors. The same identification sequence is repeated for cables containing more than 21 conductors. ICEA/NEMA Method 2 A neutral colored compound is used with single or double spiral ink tracers as required to provide positive identification through 21 conductors. The identification sequence is repeated for cables containing more than 21 conductors. ICEA/NEMA Method 3 A neutral or single colored insulation compound is surface ink printed with both conductor number and color designation to provide positive identification through 21 conductors. The identification sequence is repeated for colors containing more than 21 conductors. ICEA/NEMA Method 4 A neutral or single colored insulation compound is surface ink printed with conductor number to provide positive conductor identification through 21 conductors. The identification sequence is repeated for cables containing more than 21 conductors.

ICEA/NEMA Method 5 A color coding using braids. Also sometimes specified using colored insulation and contrasting tracers as an extension of Method I to eliminate duplicate conductors. Up to 127 positive conductor coding are available with this method. Usually specified as per: ICEA5-61-402 Table 5-1 or ICEA 5-19-81 Table 5-2. ICEA/NEMA Method 6 A color coding whereby one conductor in each layer is identified by a braid, tape, ridge, stripe or color. ICEA/NEMA Paired Color Code A coding whereby one leg of all pairs is coded white and its mate is coded in accordance with the first 21 conductors of Method 1, omitting white and repeating the sequence as necessary. Telephone Paired Color Code Five colors are paired with each of five mate colors to give 25 identified pairs. The color sequences are repeated for more than 25 pairs using colored binder strings for group identification.

Note: UL and the NEC restrict the use of green and white as colors and stripes. Special color codes are available to meet these requirements. One method is ICEA Method E-2 which is similar to Method 1 and ICEA Method E-4 which is similar to Method 2.

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

B 20140110

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Wire & Cable Color Coding Charts ICEA Method 1, Table E-1

ICEA Method 1, Table E-2

(Colored compound with tracers)

(Colored compound with tracers)

Conductor Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

Background or Base Color Black White Red Green Orange Blue White Red Green Orange Blue Black Red Green Blue Black White Orange Blue Red Orange

Tracer Color – – – – – – Black Black Black Black Black White White White White Red Red Red Red Green Green

*This conductor is in the inside of the assembly.

ICEA Method 2, Table E-1 (Neutral colored compound with tracers)

Conductor Number

1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

First Tracer Color (Wide Tracer) Black White Red Green Orange Blue White Red Green Orange Blue Black Red Green Blue Black White Orange Blue Red Orange

Second Tracer Color (Narrow Tracer) – – – – – – Black Black Black Black Black White White White White Red Red Red Red Green Green

*This conductor is in the inside of the assembly.

Conductor Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

Background or Base Color Black Red Blue Orange Yellow Brown Red Blue Orange Yellow Brown Black Blue Orange Yellow Brown Black Red Orange Yellow Brown Black Red Blue Yellow Brown Black Red Blue Orange Brown Black Red Blue Orange Yellow

Tracer Color – – – – – – Black Black Black Black Black Red Red Red Red Red Blue Blue Blue Blue Blue Orange Orange Orange Orange Orange Yellow Yellow Yellow Yellow Yellow Brown Brown Brown Brown Brown

*This conductor is in the inside of the assembly.

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] B 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Wire & Cable Color Coding Charts ICEA Method 1, Table E-2

ICEA Method 3

ICEA Method 4

(Neutral colored compound with tracers)

(Neutral or single color compound with surface printing of numbers and color designations)

(Neutral or single color compound with surface printing of numbers)

Conductor Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

Conductor Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

Conductor Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

Background or Base Color Black Red Blue Orange Yellow Brown Red Blue Orange Yellow Brown Black Blue Orange Yellow Brown Black Red Orange Yellow Brown Black Red Blue Yellow Brown Black Red Blue Orange Brown Black Red Blue Orange Yellow

Tracer Color Black Black Black Black Black Red Red Red Red Red Blue Blue Blue Blue Blue Orange Orange Orange Orange Orange Yellow Yellow Yellow Yellow Yellow Brown Brown Brown Brown Brown

Printed Legend 1 – Black 2 – White 3 – Red 4 – Green 5 – Orange 6 – Blue 7 – White–Black 8 – Red–Black 9 – Green–Black 10 – Orange–Black 11 – Blue–Black 12 – Black–White 13 – Red–White 14 – Green–White 15 – Blue–White 16 – Black–Red 17 – White–Red 18 – Orange–Red 19 – Blue–Red 20 – Red–Green 21 – Orange–Green

*This conductor is in the inside of the assembly.

Printed Legend 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

*This conductor is in the inside of the assembly.

*This conductor is in the inside of the assembly.

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

B 20140110

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Wire & Cable Color Coding Charts ICEA Method 5 (Colored compounds with tracers)

Cond. Number 1* 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43

Background or Base Color Black White Red Green Orange Blue White Red Green Orange Blue Black Red Green Blue Black White Orange Blue Red Orange Black White Orange Blue Red Orange Black White Red Green Orange Blue Black White Orange White Black White Red Green Orange Blue

First Tracer Color – – – – – – Black Black Black Black Black White White White White Red Red Red Red Green Green White Black Black Black Black Black Red Red Black Black Black White White Red White Red White Black White White Red Red

Second Tracer Color – – – – – – – – – – – – – – – – – – – – Red Red White White White White Green Green Green Orange Green Orange Orange Orange Blue Blue Green Green Green Blue Green Green

Cond. Number 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86

Background or Base Color Black White Red Green Orange Blue Black White Red Green Orange Blue Black White Red Green Orange Blue Black White Red Green Orange Blue Black White Red Green Orange Blue Black Red Green Orange Blue Red Green Blue Orange Green Black White Blue

First Tracer Color White Black White Orange Red Red Orange Black Orange Red Black Black Orange Orange Orange Black Green Green Red Orange Black Orange White White Green Green Green White Red Red Orange Orange Red White White White White Black White Red Green Green Green

Second Tracer Color Blue Blue Blue Red Blue Orange Red Orange Black Blue Blue Orange Green Green Green Blue Blue Orange Blue Blue Blue Blue Red Red Blue Blue Blue Red Black Black Blue Blue Black Green Green Orange Orange Green – – – – –

Cond. Number 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127

Background or Base Color Black White Red Green Blue Black White Red Green Orange Yellow Yellow Yellow Yellow Yellow Yellow Yellow Black White Red Green Orange Blue Black White Green Orange Blue Black Red Green Orange Blue Black White Red Orange Blue Black White Red

First Tracer Color Orange Orange Orange Orange Orange Blue Blue Blue Blue Blue – Black White Red Green Orange Blue Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow Yellow

Second Tracer Color – – – – – – – – – – – – – – – – – – – – – – – Red Red Red Red Red White White White White White Green Green Green Green Green Blue Blue Blue

*This conductor is in the inside of the assembly.

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] B 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Recommended Reel Handling Practices How to Handle Cable Reels

Cradle both reel flanges between forks.

Upended heavy reels will often arrive damaged. Refuse or receive subject to inspection for hidden damage.

Reels can be hoisted with a shaft extending through both flanges.

Do not lift by top flange. Cable or reel will be damaged.

Lower reels from truck using hydraulic gate, hoist or fork lift. LOWER CAREFULLY!

Never allow forks to touch cable surface or reel wrap.

Always load with flanges on edge and chock and block securely.

Never drop reels.

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

C 20170123

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

NOTES

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Steel Reel Specifications I-Beam Tire Fluted Steel Reel—Type RMT NOTE — When required, cable test hole in the flange shall not have more than 3 flutes removed to provide this opening. The cable test hole shall be reinforced along the cutout with a metal equal to or greater than that required for use in the drum of the reel. Height of cable test hole to be no greater than onehalf the length.

30° TRAVERSE

Y”

1” RADIUS LAG OPENING

FLANGE DIAMETER

DRUM DIAMETER

THE LAG OPENING SHOULD BE WELL ROUNDED AND GROUND SMOOTH

TIRE

HEAD SHEET

DRUM

INNER RING ARBOR HOLE FLUTES LONG CROSS ARM SHORT CROSS ARM

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

D 20140110

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Steel Reel Specifications General Purpose Steel Fluted Returnable Reels for Wire and Cables—Class 1 Type*

–Reel Dimensions– Max. Arbor Max. Fl Trav Drum Overall Hole Number Width Diameter Flutes (in) (in) per Hd

RM 42 RM 48 RM 54 RM 60 RM 66 RM 72 RM 72 RM 78 RMT 84 RMT 84 RMT 84 RMT 90 RMT 90 RMT 90 RMT 96 RMT 98 RMT** 108

24 24 32 32 32 36 36 36 36 45 45 45 45 54 60 60 74

24 24 32 32 36 40 48 48 42 42 56 42 56 56 42 56 56

33 33 41 41 41 45 45 45 45 55 55 55 55 64 71 71 85

3.25 3.25 3.25 3.25 3.25 3.25 3.25 3.25 5.25 5.25 5.25 5.25 5.25 5.25 5.25 5.25 5.25

24 24 30 30 32 40 40 40 40 40 40 40 40 40 40 40 40

Tire Size (in)

2x5/16 2x5/16 2x5/16 2x5/16 2-1/2x1/2 2-1/2x1/2 2-1/2x1/2 2-1/2x5/8† 7.5lb/ft, 3" I-Beam 7.5lb/ft, 3" I-Beam 7.5lb/ft, 3" I-Beam 7.5lb/ft, 3" I-Beam 7.5lb/ft, 3" I-Beam 7.5lb/ft, 3" I-Beam 7.5lb/ft, 3" I-Beam 7.5lb/ft, 3" I-Beam 7.5lb/ft, 3" I-Beam

–––––Cross Arms––––– U.S.S. Long Short (ga) (in) (in)

8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8

5x2 5x2 5x2 5x2 6x2 6x2 6x2 6x2 7-7/8x2 7-7/8x2 7-7/8x2 7-7/8x2 7-7/8x2 7-7/8x2 7-7/8x3 7-7/8x3 7-7/8x3

4x2 4x2 4x2 4x2 5x2 5x2 5x2 5x2 6x2 6x2 6x2 6x2 6x2 6x2 6x3 6x3 6x3

Drum U.S.S. (ga)

12 12 12 12 12 12 12 12 10 10 10 10 10 8 8 8 8

Inner (Flange) Maximum Ring Head –––Capacity––– Dimensions Sheet (lb) (kg) (in) U.S.S. (ga) 3-3/4x3/16 3-3/4x3/16 3-3/4x3/16 3-3/4x3/16 3-3/4x3/16 3-3/4x1/4 3-3/4x1/4 3-3/4x1/4 4x1/4 4x1/4 4x1/4 4-1/4x1/4 4-1/4x1/4 4-1/4x1/4 4-1/2x5/16 4-1/2x5/16 4-1/2x5/16

16 16 16 16 16 16 16 16 16 16 16 16 16 16 14 14 14

1,956 887 3,072 1,393 4,464 2,024 6,360 2,884 7,680 3,482 10,260 4,654 7,872 3,570 10,752 4,876 13,608 6,171 17,004 7,711 11,196 5,050 21,036 9,540 15,216 6,900 18,252 8,277 26,000 11,719 26,000 11,719 30,000 13,605

* RM—Flat bar tire ** Generally used for aluminum wire and cable † Alternate size is 3x1/2 inch RMT—I-Beam Tire NOTE—Tie holes, if necessary, shall be in the flat portion of the head sheet. There will be no holes in the flute itself. NOTE—A range of 3 to 3.25-inch and 5 to 5.25-inch arbor hole diameter shall be permitted for existing reels until the year 2005.

Welding Requirements for Class 1 Reels Head sheet to tire—at all radii of flute-intermittent weld Head sheet to inner ring—at all radii of flute-intermittent weld Drum to inner ring—intermittent weld Cross arm to cross arm—continuous weld Cross arm to inner ring—continuous weld Cross arm to hub—continuous weld Back-up plate to hub and cross arm—continuous weld Port frame—continuous weld All welds shall reflect good welding practice with proper penetration.

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] D 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Cabling

Cable A

1500' linear

Cable B

1500' linear

A 1500' linear B 1500' linear C 1500' linear 4500' linear

Cable C

1500' linear

4500' linear

Cabled (Triplexed) Cables Cable A

1500' linear

Cable B

1500' linear

Cable C

1500' linear

CKT

1350' linear

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

I 20140506

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

NOTES

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Metric Size to AWG Size Area (mm2)

Size AWG/MCM

Nominal Overall Diameter (mm)

Nominal Overall Diameter (in)

Number of Wires

Area (mm2)

Size AWG/MCM

Nominal Overall Diameter (mm)

Nominal Overall Diameter (in)

Number of Wires

1010 1000 887 800 760 633 507 500 400 380 304 300 253.4 240 203 185 177 152 150 127 120 107.2 95 85.01 70 67.43 53.49 50

2000

41.45 41.14 38.76 36.81 35.87 32.74 29.26 29.05 25.97 25.35 22.68 22.46 20.65 20.09 18.49 17.64 17.30 16.00 15.85 14.61 14.15 13.41 12.60 11.94 10.86 10.64 9.47 9.15

1.632 1.620 1.526 1.448 1.412 1.289 1.152 1.143 1.023 0.998 0.893 0.884 0.813 0.792 0.728 0.695 0.681 0.630 0.624 0.575 0.558 0.528 0.497 0.470 0.427 0.419 0.373 0.361

127 91 127 61 91 91 61 37 37 61 61 37 37 37 37 37 37 37 19 37 19 19 19 19 19 19 19 19

42.41 35 35 33.62 26.67 25 21.15 16 13.30 10 8.37 6.0 5.26 4.0 3.31 2.5 2.08 1.5 1.31 1.0 0.82 0.75 0.52 0.50 0.33 0.25 0.20

1

8.43 7.65 7.56 7.42 6.61 6.39 5.89 5.13 4.67 4.05 3.71 3.12 2.95 2.55 2.34 2.01 1.85 1.56 1.47 1.29 1.02 0.98 0.81 0.80 0.64 0.56 0.51

0.332 0.302 0.298 0.292 0.260 0.252 0.232 0.202 0.184 0.160 0.146 0.123 0.116 0.101 0.092 0.080 0.073 0.062 0.058 0.051 0.046 0.039 0.032 0.031 0.025 0.022 0.020

19 19 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

1750 1500 1250 1000

750 600 500 400 350 300 250 4/0 3/0 2/0 1/0

2 3 4 6 8 10 12 14 16 18 20 22 24

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

E 20140110

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

NOTES

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Copper Conductor Stranding Chart Class A thru M Size AWG

Approx. O.D.

Pounds per 1000 ft

Concentric Strand Class A

Concentric Strand Class B

Concentric Strand Class C

Concentric Strand Class D

Rope Lay Concentric Strand Class G

Rope Lay Concentric Strand Class H

Rope Lay Bunch Strand Class I 24AWG (.201")

36 35 34 33 32 30 30 29 28 27 26 25 24 23 22 21 20 18 16 14 12 10 9 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250000 300000 350000 400000 500000 600000 750000 1000000

0.0050 0.0056 0.0063 0.0071 0.0080 0.0089 0.0100 0.0113 0.0126 0.0142 0.0159 0.0179 0.0201 0.0226 0.0254 0.0285 0.0363 0.0456 0.0576 0.0726 0.0915 0.1160 0.1600 0.1460 0.1840 0.2320 0.2600 0.2990 0.3320 0.3730 0.4190 0.4700 0.5280 0.5750 0.6300 0.6810 0.7280 0.8130 0.8930 0.9980 1.1520

0.07570 0.09540 0.12030 0.15170 0.19130 0.24130 0.30420 0.38360 0.48370 0.61000 0.76920 0.96990 1.22300 1.54200 1.94500 2.45200 3.15400 5.01500 7.97400 12.68000 20.16000 32.06000 40.42000 51 80.9 129 162 205 259 326 411 518 653 772 925 1080 1236 1542 1850 2316 3086

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 7 7 7 7 7 7 7 7 19 19 19 19 37 37 61 61

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 7 7 7 7 7 7 7 7 7 7 7 7 19 19 19 19 19 37 37 37 37 37 61 61 61

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 19 19 19 19 19 19 19 19 19 19 19 19 37 37 37 37 37 61 61 61 61 61 91 91 91

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 37 37 37 37 37 37 37 37 37 61 61 61 61 61 91 91 91 91 91 127 127 127

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 49 49 49 49 49 49 49 49 49 133 133 133 133 133 259 259 259 259 259 427 427 427

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 133 133 133 133 133 133 259 259 259 259 259 427 427 427 427 427 703 703 703

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 26 N/A 41 63 105 N/A 161 210 266 342 418 532 637 735 882 980 1225 1470 1862 2527

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

G 20170303

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

NOTES

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Wire & Cable Glossary of Terms AWG Abbreviation for American Wire Gauge. AWM Designation for appliance wiring material. Alternating Current Electric current that continually reverses its direction. Is expressed in cycles per second (hertz or Hz). Ambient Temperature The temperature of the medium (gas, liquid or earth) surrounding an object. American Mustang A premium grade thermoset cord, UL listed as SOOW or SJOOW, CSA SOOW and SJOOW. American Wire Gauge (AWG) A standard system for designating wire diameter. Also referred to as the Brown and Sharpe (B&S) wire gauge. Ampacity See Current Carrying Capacity. Ampere The unit of current. One ampere is the current flowing through one ohm of resistance at one volt potential. Anneal Relief of mechanical stress through application of heat and gradual cooling. Annealing copper renders it soft and less brittle. Audio Frequency The range of frequencies audible to the human ear. Usually 20–20,000 Hz. Braid A fibrous or metallic group of filaments interwoven in cylindrical form to form a covering over one or more wires. Breakdown Voltage The voltage at which the insulation between two conductors breaks down. Bunch Stranding A group of wires of the same diameter twisted together without a predetermined pattern. Cabling The twisting together of two or more insulated conductors to form a cable. Capacitance The ability of a dielectric material between conductors to store electricity when a difference of potential exists between the conductors. The unit of measurement is the farad, which is the capacitance value that will store a charge of one coulomb when a one-volt potential difference exists between the conductors. In AC, one farad is the capacitance value that will permit one ampere of current when the voltage across the capacitor changes at a rate of one volt per second. Circuit (Electric) The complete path of an electrical current. When the continuity is broken, it is called an open circuit; when continuity is maintained, it is called a closed circuit. Cold Flow Permanent deformation of the insulation due to mechanical force or pressure (not due to heat softening).

Color Code A system for circuit identification through use of solid colors and contrasting tracers. Compound An insulating or jacketing material made by mixing two or more ingredients. Concentricity In a wire or cable, the measurement of the location of the center of the conductor with respect to the geometric center of the surrounding insulation. Conductor An uninsulated wire suitable for carrying electrical current. Contacts The parts of the connector that actually carry the electrical current and that touch the equivalent parts in the mating connector. Continuity Check A test to determine whether electrical current flows continuously throughout the length of a single wire or individual wires in a cable. Cord A flexible insulated wire suitable for carrying electric current. Corona Ionization of air surrounding a conductor caused by the influence of high voltage. Causes deterioration of insulation materials. Crazing The minute cracks on the surface of plastic materials. CSA Abbreviation for Canadian Standards Association, a nonprofit, independent organization that operates a listing service for electrical and electronic materials and equipment. The Canadian counterpart of the Underwriters Laboratories Current Carrying Capacity The maximum current an insulated conductor can safely carry without exceeding its insulation and jacket temperature limitations. It is dependent on the installation conditions. Decibel (db) A unit that expresses differences of power or voltage level. It is used to express power loss in passive circuits or cables. Dielectric Strength The voltage that an insulation can withstand before breakdown occurs. Usually expressed as a voltage gradient (such as volts per mil). Direct Capacitance The capacitance measured directly from conductor to conductor through a single insulating layer. Drain Wire In a cable, the uninsulated wire laid over the shield component or components and used as a ground connection. Drawing In wire manufacture, pulling the metal through a die or series of dies to reduce diameter to a specified size.

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

F 20140110

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Wire & Cable Glossary of Terms Eccentricity Like concentricity, a measure of the center of a conductor's location with respect to the circular cross section of the insulation. Expressed as a percentage of displacement of one circle within the other. Elongation The fractional increase in length of a material stressed in tension. EMI Abbreviation for electromagnetic interference. Farad A unit of electrical capacitance. Filler 1) A material used in multiconductor cables to occupy large interstices formed by the assembled conductors; 2) An inert substance added to a compound to improve properties or decrease cost. Flame Resistance The ability of a material to resist the propagation of flame once the heat source is removed. Flex Life The measurement of the ability of a conductor or cable to withstand repeated bending. Frequency The number of times an alternating current repeats its cycle in one second. G An industry designation for a 2kV portable power cable consisting of 2 4 insulated conductors with ground wires placed in the valleys for use in mines and similar applications. Gauge A term used to denote the physical size of a wire. G-GC designation An industry for a 2kV portable power cable consisting of 3 insulated conductors with 2 ground wires, and a ground check conductor. For use in mines and similar applications. Ground An electrical term meaning to connect to the earth or other large conducting body to serve as an earth, thus making a complete electrical circuit. Harness An arrangement of wires and cables, usually with many breakouts, which have been tied together or pulled into a rubber or plastic sheath, used to interconnect an electric circuit. Hertz (Hz) A term replacing cycles per second as an indication of frequency. Hi-Pot A test designed to determine the highest voltage that can be applied to a conductor without breaking through the insulation. HPD Heater cord with thermoset insulation and cotton or rayon braid overall. HPN Parallel heater cord.

Hz Abbreviation for hertz. Impedance The total opposition that a circuit offers to the flow of alternating current or any other varying current at a particular frequency. It is a combination of resistance R and reactance X, measured in ohms. Inductance The property of a circuit or circuit element that opposes a change in current flow, thus causing current changes to lag behind voltage changes. It is measured in henrys. Insulation A material having high resistance to the flow of electric current. Often called a dielectric in radio frequency cable. Jacket An outer non-metallic protective covering applied over an insulated wire or cable. Jumper Cable A short flat cable interconnecting two wiring boards or devices. Lay The length measured along the axis of a wire or cable required for a single strand (in stranded wire) or conductor (in cable) to make one complete turn about the axis of the conductor or cable. Longitudinal Shield A tape shield, flat or corrugated, applied longitudinally with the axis of the core being shielded. MTW Thermoplastic insulated machine tool wire. Multiconductor More than one conductor within a single cable complex. Mylar A synthetic compound with high dielectric qualities made by DuPont and used extensively in the wire and cable industry in tape form. NEMA Abbreviation for National Electrical Manufacturers Association. Ohm A unit of electrical resistance. OSHA Abbreviation for Occupational Safety and Health Act, specifically the Williams Steiger Law passed in 1970 covering all factors relating to safety in places of employment. Plasticizer A chemical agent added to plastics to make them softer and more pliable. Potting The sealing of a cable termination or other component with a liquid that cures into an elastomer. Primary Insulation The first layer of nonconductive material applied over a conductor, whose prime function is to act as electrical insulation.

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] F 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

Wire & Cable Glossary of Terms Put-Up Packaging of finished wire or cable by size and length. PVC Abbreviation for polyvinylchloride. Rated Voltage The maximum voltage at which an electrical component can operate for extended periods without undue degradation or safety hazard. REA Abbreviation for Rural Electrification Administration, which is part of the US Dept. of Agriculture. REA establishes specifications and provides approval for telephone station wire and power cables. Resistance A measure of the difficulty in moving electrical current through a medium when voltage is applied. It is measured in ohms. RFI Abbreviation for radio frequency interference. S Heavy duty, rubber insulated portable cord. Standard copper conductors with separator and individual rubber insulation. Two or more color-coded conductors cabled with filler, wrapped with separator and rubber jacketed overall 600V. SEO Same construction as STO, except insulation and jacket are made of Thermoplastic Elastomer Rubber (TPE) 600V. SEOOW Same construction as SEOW, except with oil resistant insulation. SEOW Same construction as SEO, except suitable for outdoor use. Usually UL listed for continuous submersion in water 600V. Separator Pertaining to wire and cable, a layer of insulating material such as textile paper, Mylar, etc., which is placed between a conductor and its dielectric, between a cable jacket and the components it covers, or between various components of multiple conductor cable. It can be utilized to improve stripping qualities and/or flexibility, or can offer additional mechanical or electrical protection to the components it separates. Shield A tape shield, or braid of metal, usually copper, aluminum or other conducting material, placed around or between electric circuits or cables or their components to contain any unwanted radiation, or to keep out an unwanted interference. SJ Junior hard service rubber insulated pendant or portable cord. Same construction as SJT, except insulation and jacket is thermoset (rubber) 300V. SJE Same construction as SJT, except insulation and jacket made of Thermoplastic Elastomer Rubber (TPE)300V. SJEO Same construction as SJO, except insulation and jacket made of Thermoplastic Elastomer Rubber (TPE).

SJEOW Same construction as SEOW except 300 volt rated. SJO Same as SJ, but oil resistant outer jacket. Can also be made “water resistant.” 300V, 60°C, 75°C, 900°C or 105°C. SJOOW Same as SOOW except 300 volt rated. SJT Junior hard service thermoplastic conductors with overall thermoplastic jacket, 300V, 60°C, 75°C, 900C or 105°C. SJTO Same as SJT, but oil resistant thermoplastic outer jacket. SLC Stage Lighting Cable. A 600-volt single conductor cable for use with indoor and outdoor stages, fairs and carnivals. SO Hard service cord. Same construction as type S, except oil resistant thermoset jacket. 600V, 600°C to 105°C. SOOW Same as SOW except oil resistant insulation. SOW Same as SO except suitable for outdoor use. SP-1 All rubber, parallel jacketed, two conductor light duty cord for pendant or portable use. 300V. SP-2 Same as SP-1, but heavier construction, with or without third conductor for grounding purposes. 300V. SP-3 Same as SP-2, but heavier construction for refrigerators or room air conditioners. 300V. Spacing Distance between the closest edges of two adjacent conductors. Spark Test A test designed to locate pinholes in the insulation of a wire or cable by application of a voltage for a very short period of time while the wire is being drawn through a field of electrodes. SPE Same construction as SP-1, except insulation and jacket made of Thermoplastic Elastomer Rubber (TPE). Spiral Wrap The helical wrap of a tape or other material over a core or component. SPT-1 Same as SP-1, except all thermoplastic, 300V. With or without third conductor for grounding. SPT-2 Same as SP-2, except all thermoplastic. 300V. With or without third conductor for grounding. SPT-3 Same as SP-3, except all thermoplastic. 300V. With or without third conductor for grounding.

www.buyawg.com TOLL FREE 1.800.342.7215

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.

F 20140110

APPENDIX

Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected]

Wire & Cable Glossary of Terms ST Hard service cord, jacketed. Same as type S, except all plastic construction. 600V, 600°C to 105°C. STO Same as ST, but with oil resistant thermoplastic outer jacket. 600V, 600°C to 105°C. Strand A single uninsulated wire. Stranded Conductor A conductor composed of wires or groups of wires twisted together. Surge A temporary and relatively large increase in the voltage or current in an electric circuit or cable. Also called a transient. SV Vacuum cleaner cord, rubber insulated with rubber jacket, rated at 300V. SVE Same construction as SV, except insulation and jacket made of Thermoplastic Elastomer (TPE). SVT Same as SV, except all plastic construction. With or without third conductor for grounding purposes only. 300V, 600°C to 105°C. TC Tray Cable. Multi-conductor cable specifically approved for use installed in cable trays. Tensile Strength The pull stress required to break a given specimen. Thermoplastic A material that softens and melts when heated and becomes firm on cooling.

Thermoset A material that hardens or sets when heat is applied and that, once set, cannot be resoftened by heating. The application of heat cures or vulcanizes the material. TPE Abbreviation for Thermoplastic Elastomer. UL Abbreviation for Underwriters Laboratories, a nonprofit independent organization that operates a listing service for electrical and electronic materials and equipment. Voltage The term most often used in place of electromotive force, potential, potential difference or voltage drop to designate the electrical pressure that exists between two points and is capable of producing a current when a closed circuit is connected between two points. VW-1 A flammability rating established by Underwriters Laboratories for wires and cables that pass a specific vertical flame test, formerly designated FR-1. W (Type) An industry designation for a 2kV portable power cable consisting of 1–6 insulated conductors. For use in mines and similar severe duty applications. W UL designation for outdoor listed flexible cord that is tested for sunlight and weather requirements (e.g., 5TW). Water Resistant UL designation for cords that have an insulation on the individual conductors that passes UL requirements (e.g., 5T Water Resistant or 5T Dry 105°C, Water Resistant 60°C).

www.buyawg.com APPENDIX

TOLL FREE 1.800.342.7215 Telephone 1.954.455.3050 Fax 1.954.455.9886 [email protected] F 20140110

Information on this sheet subject to change without notice. Copyright © 2018, American Wire Group, Inc.