35 1 689KB
1
2
3
4
5
6
8
7
D
D
Main power switch in M.R.
EPS power unit
K LA
LA1
LB
LB1
LC
LC1
L1
R
L2
S
L3
EPS13
N N
★
PE PE
C
PT
Q
T Control cable number or terminal number
Power of user 380V
Main power switch(by others)
L1
U1
L2
V1
L3
W1
KDY Running contactor 1 2
U3
R
U
S
V
3
4
V3
T
W
5
6
W3
BL6-U 12V
+12V
0V
0V
1/5
141 116
IA
A
2/6
PG-V6X/JENDAT IB
B
G4
3/7
GND
4/8
YJ
E-KIB-A
PG
C
Controller interface board
GE
Brake resistor
B1
RZD
B2 B
B
A
A
QianJianqiang Design JiangYongliang Check Mian circuit Approve Zhengyanfeng
Date
1
2
3
4
5
6
2016.12.5
7
Draw No. TRF110 16 Sheets 1 Sheet Asynchronous motor Remark
8
1
2
3
4
5
6
8
7
D
D
Main power switch(by others)
EPS power unit LA1
LB
LB1 LC1
L1
R
L2
S
L3
EPS13
N N
★
PE PE
C
Q L1
U1
L2
V1
Running contactor
KDY
R
U
1
S
V
3
2
U3
4
V3
6
W3
KDY KDY
W1
L3
T Control cable number or terminal number
Power unit 380V
K LA
LC
PT
Main power switch in M.R.
5
W
T
32
22
31
21
BL6-U 1/5
141
2/6
116
3/7
GND
4/8
YJ
G4
E-KIB-A
Controller interface board
KFX
+5V
+5V
9
0V
7
0V
A+
5
A+
A-
6
A-
B+
8
B+
B-
1
B-
C+
11
C+
C-
10
C-
12
D+
SPG-V6/JENDAT D+
Mian motor
D-
13
D-
R+
3
R+
R-
4
C
PG
R-
GND-E
HEIDEHAIN 1387
B1
B
B
RZD
Brake resistor
B2
A
A
QianJianqiang Design JiangYongliang Check Approve Zhengyanfeng
Date
1
2
3
4
5
6
Main circuit
2016.5.14
7
Draw No. TRF110 16 Sheets 2 Sheet Synchronous motor Remark
8
1
2
3
4
5
6
8
7
D
D
Control power transformer TC1
100 AC110V
F2(1P2A) 101
Control power breaker
F1(3P6A) 0V
U1
R1
+
103
DC110V 380V
S1
102
-
400V
V1
415V
C
C
200 AC220V
W1
F3(1P4A)
T1
Phase relay KXX
L1
L2
14
11
201 L N AVR Switch power V+ V-
L3 12
GND1 24V
141 116
B
B
A
A
Design Check Approve Date
1
2
3
4
5
6
QianJianqiang
Control power & Brake circuit 2016.5.14
7
Draw No. Sheets Sheet Remark
TRF110 16 3
8
1
2
3
4
5
6
8
7
D
D
Running contator
F4(1P4A) M1-P06
M2-P12
103/400/T1/200
44
KDY 43
Brake contactor
KLZ 1
M5-P03
M5-P04
BK0
M300
Brake voltage
Brake contactor
2 M2-P14
Brake
RA-P04
RA-P05
LZ1
BK1
M5-P05
M2-P15
KLZ 4
3
BK2
Short-circuited
M2-P13
M1-P05 102/401/N/201
301
Power supply terminal
DC110V 103
102
AC220V
T1
N
AC220V
200
201
DC220V
400
401
DC24/48V 400
401
+
C
EPB J5 J6 C
Brake release device
AC220V
N/201
N
TC2
Note 1
+
L
T1/200
400 DC220V/DC48V
401
-
B
B
Note 1:When brake voltage is DC220V, TC2 adopts rectifier. When equipped with Yaskawa traction machine, TC2 adopts DC48v switch power. When equipped with Emergency cabinet, input power connect 200 and 201.
A
A
QianJianqiang Design Check Brake circuit Approve
Date
1
2
3
4
5
6
2016.5.14
7
Draw No. Sheets Sheet Remark
TRF110 16 4
8
1
2
3
Emergency stop in car D
Emergency stop on car top
SDC M1-P10
4
SDH
105
TA-P01
SOS-P01
SPC
100
100
Safety gear switch
Levelling pin
CIB-P06 RTES-P01
EB-P07 CIB-P05
6
SNQ
RTES-P03
106
HB-P07
TA-P02
111
HD-P01
SXJ
108
PC2-P01
PC2-P04 SHC1 PC2-P02
109
HB-P08
CIB-P07
SHC2
HA-P07
Top final limit SSJ
113
Emergency power driven
GJ M3-P05
CIB-P08 TA-P03
110
S5
M3-P06
110A
Emergency stop in switch box of pit
Emergency stop in maintenance box of pit SKT2
SKT1
HD-P03
Emergency Stop in High Platform
Rope breakage switch PC1-P02
115a
PC2-P05 HD-P02
112
DJ
Safety circuit
D
CW buffer switch
Car buffer switch
Bottom final limit
SOS-P03
Inspection on car top
M3-P07
8
7
Emergency stop of rear door
SDT
EB-P09
5
PC1-P04
SKS
PC1-P05 HD-P04
G2-P01
SDR
115b
115d
115e PC1-P01
Up overspeed switch
Handwheel switch
G2-P03 G2-P04
G2-P07
SPC
115c
G2-P09
SCS
115
G2-P06
Speed governor down overspeed switch RB-P01 RB-P03 SXS
114
114a
HA-P08
C
C
Emergency stop in control cabinet
M5-P07/M6-P09/G4-P02
Phase relay
SJT M3-P08
M1-P04
KXX 14
G1-P01
11
141
J7-5(X29+)
116
M1-P03
Door interlock circuit
G1-P02
J7-2(X31+)
G1-P03
J8-3 (X32+) Front landing door on 1st floor HE1-P03
SMn
SM1
Front landing door on N floor
HE1-P01
Rear car door switch
Front car door switch
TA-P05
117
B
SMJ GS-P01
GS-P03 RGS-P03
SMJ
TA-P04
117A
HE2-P01
RGS-P01
SMn
Rear landing door on 1st floor SM1 HE2-P03
118B Rear landing door on N floor
TA-P06/M6-P10
G2-P12
G2-P13
118
G1-P04
J7-3(X30+)
118A
Short-circuited
Main control board M5-P08/M6-P11
B
M2-P06
MU-V61 VL2
J8-2(X32-) J7-4(X29-) M1-P09
Note:1. When there is no rear car door, short connect 117A and 118 of BY terminal of interface board E-CIB-A on car top.
G1-P05
J7-1(X30-)
101
2. When there is no rear landing door, short connect 118 and 118B of D1 terminal of interface board E-KIB-A on control cabinet.
A
A
QianJianqiang Design Check Safety door lock circuit Approve
Date
1
2
3
4
5
6
2016.5.14
7
Draw No. Sheets Sheet Remark
TRF110 16 5
8
1
2
3
4
5
6
8
7
D
D
HA-P05
HB-P05
HA-P03
HB-P03
Top terminal 2
Bottom terminal 2
SDZ2
XDZ2
HA-P02
HB-P02
Up door zone
Down door zone
SMQ
KBK1
XMQ
DZ-P06
DZ-P03
TA-P9
TA-P10
RA-P02
KBK2
RA-P03
+24V
44
44
32
KDY
KLZ 43
31
M2-P09
Red KFX 43
M2-P10
G5-P02
3#
EPS 4#
G5-P03
G4-P04
Black M2-P08
XF
G5-P01
XF2
G5-P10
SDF
Electric lock
XDZ1
Fireman switch 2
Bottom terminal1
GND
Fireman switch 1
SDZ1
G5-P05
GND Input signals when EPS drives microprocessor
Top terminal 1
XXV
G4-P03
GND
KCZ
Bottom limit
SXV
G5-P04
GND
GND
Optional for M.R. overloading
Shown in Inspection circuit
Top limit
M2-P11
RA-P01
GND
Temperature control signal
M1-P02
DZ-P04
KWK
M1-P01
Connect when lift speed ≥2.0m/s
GND
FAR
HB-P06
GND
Fan:DC24V
HA-P06
Brake detecting switch 2
+24V
Brake detecting switch 1
GND2
G5-P09
C
C GND
+24V
JX(X0)
MS(X1)
MX(X2)
121(X5)
122(X6)
124(X8)
123(X7)
119(X3)
120(X4)
Optional Y1
COM1
COM3
Y7
Y9
XMQ(X10)
SMQ(X9)
KBK1(X15)
E-KIB-A
Y6
COM4
Y8
Y10
COM5
24V
Y11
COM
CAN+ 2H
M2-P04
M2-P01 Economic resistor contactor(Optional)
M2-P05 13
KFX 14 A1
101 B
M2-P07 Connect when there is Fire fighting function
KJR
KDY A2
Running contactor
LD1
Brake contactor
KLZ LD2
M7-P12 M7-P11
A1
A2
CAN-
X17
M7-P09
5
3
6
A2
1
C-
M7-P10
M7-P07
2
116
4
117
CZ(X25)
YJ(X18)
G1 5
XF2(X24)
X20
Optional
CN1
3
118A 101
XF(X12)
118
M7-P08 24V+ GND C+
A1
WK(X21)
M7 1
24V+ GND C+
2L
X11
M2-P03
Star shorted contactor
M2-P02
KBK2(X19) X16
1
2
J6
6
C5
5
2
A1
KFX
24V
GND
C+
3
J7
1
4
2
J8
3
J1
MU-V61 VL2
C-
TC-P01 TC-P02 TC-P03 TC-P04
A2
Spare
Spare
24V
GND
C+
8
C-
HC-P01 HC-P02HC-P03 HC-P04
Car top PCB communication
J6
7
4
B
Hop communication 118A
M2-P06
100
M1-P10
CB+
CB-
GND1
For Twin control/Group control
S1
4 3 2 1
PE CANPE
A
QianJianqiang Design Check Control corcuit Approve
GND
Date
1
2
3
4
5
6
2016.5.14
7
TRF110 16 6
Draw No. Sheets Sheet Remark
8
A
1
2
3
4
5
6
7
8
D
D
Emergency power driven
Inspection on car top
GJ
DJ CIB-P02 TA-P11
M3-P01
130
CIB-P01
M3-P02
130A
S2
JX
COM in M.R. FMG
JX (X0)
S6 FMS
M3-P03
MS
MS (X1)
E-KIB-A
Jog up in M.R. FMX
MX
M3-P04
COM on car top DMG
Jog up on car top
MX (X2)
Jog down in M.R.
DMS
CIB-P03 TA-P07 C
Jog down on car top
DMS
S3
C
DMS
CIB-P04 TA-P08 DMX
S4
B
B
A
A
Design QianJianqiang Check Approve Date
1
2
3
4
5
6
2016.5.14
Draw No. Sheets Inspection circuit Sheet Remark
7
TRF110 16 7
8
1
2
3
4
5
When using Blue Light SJT-150,leave them
6
8
7
For double entrance D
D
LWD-P04 24V
GND
RDR-P08
GND
C-
C+
RDM-P09
GND
DR-P08
GND
Light load
KBZ
KMZ
KCZ
Half load
Full load
Overload
LWD-P02 LWD-P03
TC
X8
LWD-P07
X9
2KAB1
KMV2
Door close limit 2
1KAB1
Door open limit 2
RDM-P08
RDM-P07
DR-P09
KAB2
GMV2
KMV2
KAB1
X6
X5
GMV1
Light curtain 1
RDR-P09
X11
X10
Safety edge 1
GMV2
Light curtain 2
LWD-P08
GND
1KAB2
Safety edge 2
TC-P04
TC-P03
TC-P02
TC-P01
2KAB2
KQZ
DM-P09
GND
X4
Door close limit 1
DM-P08 GMV1
X2
KMV1 Door open limit 1
DM-P07 KMV1
X1
X0
E-CIB-A
For double entrance
C
Y0
Y1
Y3
Y4
JR1
JR0
Arrival chime
CM1
KM
GM
CM2
KM2
Door close 2
GM2
GND
+24V
VB-P01
black
L31
+24V
L33
VB-P02
J1
yellow
VB-P02
Door open 2
VB-P01
Door close 1
CN1
J3
J4
buzzing
BEL
Door open 1
CN2
BY-P05
BY-P04
EA-P02
TB-P08
VB-P04
VB-P03
RDM-P12
RDM-P11
RDM-P10
DM-P12
DM-P10
DM-P11
CN3
red
C
JR2
BL2000-JDB
GND
Optional
Lighting fan control
B
B
A
A
QianJianqiang Design Check Approve
Date
1
2
3
4
5
6
Car top PCB control circuit
2016.5.14
7
Draw No. Sheets Sheet Remark
TRF110 16 8
8
1
2
3
4
5
6
Applicable for MRL lift
L31
201 200
FXS
Main door
VVVF Door Operator
D
U
U5
V
V5
W
W5
L
200
N
201
N1 Car Top Light Switch
G6-P01 L31
Door Motor
SDM
TB-P08
[6]
KMV1
B3(PC2) [5]
GMV1 GND
C2、C3(PAC) [4]
SGK
DM-P01 DM-P02
Control cabinet light
JR1
EA-P02
SJM1
EA-P03
Car light switch
DM-P07 DM-P08
GM
2(CD)
[3]
1(OD)
[2]
KM
8(CM)
[1]
CM1
V
SFA
13
DM-P11
TB-P09 Fan AC220V
FAR
14
For floor number above six(choose either it or DC24V fan) Hoistway Light Switch (Pit)
SZMf 2
N2
SZMk L32A
1
2 L35
1
ECM1
Door motor
N
201
Hoistway light
DM-P01 DM-P02
+24V PGA Encoder
PGB COM
KMV1
TB3
GMV1
TB1
GND
TA1/TA3
KM
DI5
GM
DI6
CM1
COM
DM-P07
U
U6
V
V6
W
W6
L
200
N
201
L32B
3
2
3
ECMn
EKM
Pit Light
RDM-P01
Pit Light Switch
RDM-P02
G6-P04
Pit light Socket
EM
XK EM3 VA-P05 G6-P05
VA-P04
Hoistway light for car top(optional) B
Q1 KMV2
[6]
B2(PC1) B3(PC2) [5] C2、C3(PAC)
DM-P08
2
Door motor
SKK
Vice door
200
C
DM-P10 L32
VVVF Door Operator
ST
VVVF Door Operator
L
FANZM/FS-P01
ZM/FS-P02
KDY
DM-P12
TB-P09
EM2
Car fan
FA
EA-P04
EM1 ZM/FS-P04
Car light
W7
W
B
car light
EM
L33
DM-P09
Hoistway Light Switch (M.R.)
V7
XG
ZM/FS-P05
E-CIB-A
U7
U
EGM
Control cabinet light switch Control cabinet socket
Car fan switch
C
D
VA-P02
XD
Car Top Light Socket
G6-P02 N1
Optional for MRL
B2(PC1)
Speed governor reset
TB-P09
EDM
Car Top Light
VA-P01
TB-P08
XS2
XS1
Speed governor action
8
7
GMV2 GND
[4]
L3
L31
RDM-P07 RDM-P08
Lighting Breaker (1P4A) Including car lighting, safety lighting.
N
RDM-P09
DM-P09
N1
Q2
DM-P11 DM-P12 DM-P10
2(CD)
[3]
GM2
1(OD)
[2]
KM2
8(CM)
[1]
CM2
L32
RDM-P12 RDM-P11
Hoistway lighting breaker(1P10A)
N2
RDM-P10
Note: The terminal no. outside ( ) are for Shenling operator, the terminal no. in ( ) are for Eshine door operator. The number in [ ] are cable no. for Shenling door operator.
A
A
QianJianqiang Design Check Approve
Date
1
2
3
4
5
6
Door operator Lighting circuit
2016.5.14
7
Draw No. TRF110 16 Sheets Sheet 9 Remark
8
1
2
3
4
5
6
Electric lock
+24V
HC-P01
Fireman switch
(locked when switch on)
GND
HC-P02
8
7
(fireman function when switch on)
C+
HC-P03 HC-P04
CD
4
3
2
1
2
3
4
1
DZZ 2
Arrival gong output(ne gtive edge triggering)
3
4
-24V
+24V
1
BY/BY1
BY1
1
4
3
DZD 2
3
4 Top arrival light
Bottom arrival light
+24V
1
SM
C
2
BY0
4
3
2
J2 2 +24V
3
4
1
2
3
+24V
4
1
2
J3
HAH
J1
1
4
3
2
HAH 3
+24V
4
1
J2
BY/BY1 2
3
4
1
+24V
2
J3 3
4
J1
1
4
3
2 1
2 +24V
3
4
1
2 +24V
3
4
J3
J2
HAH
HAH
J1
1
4
3
2
J1
1
1
D
SM
C
BEL
N floor down call
Vice landing door lock (Optional for two-circuit)
N-1 floor up call
2nd floor up call
Lift A 8
BL6-U
J6
7 2
CB+
CB+
CB+
CB-
CB-
CB-
7
GND1
GND1
GND1
2
Arrival light output
J6
5
1
2
Full Load
6
5
Inspection
3
4
1 4
J1 J2
4
3
3
Up Call +24V
2
2
1
1
4
4
B
2
6
7
8
9 10 11 12 14 15 16 17 J5
BL2000-HXJ-V9
4
J2
J1
J1 Call box LCD display transformer board
HAH J3
3
3
Down Call
2
+24V
J3
2
1
1
3
J2
HAH A
2
D C B A S X CZ MZ XF JX
E-KIB-A
HC-P04 M7-P06
HC-P03 M7-P05
When two lifts are of duplex control and use two seperate simplex HOP, please do the wiring as the above. When use one duplex HOP, please only connect the duplex wires.
HC-P02 M7-P03
HC-P01 M7-P01
HC-P04 M7-P06
V+ V- E
J3
2
Vice landing door lock (Optional for two-circuit)
Indicator
BL6-U
1
1
Arrival gong output
J6 6
HC-P03 M7-P05
HC-P02 M7-P03
E-KIB-A
HC-P01 M7-P01
B
2
1st floor up call
Lift B
8
J6 1
2nd floor down call
1
2
3
4
5
6
Design Check Approve
QianJianqiang
Date
2016.5.14
Draw No. TRF110 Landing call circuit 16 Sheets 10 Sheet LCD display Remark transformer board
7
8
A
1
2
3
4
5
6
J1
BL6 GND
24V
4
GND
C+
J9
>
3
1st floor car call
C-
C+
>
24V
SN17 4
SN1
CN1
D
8
7
ND1
+24V
J1
JE1
3 2
D
+24V
JN1
ND17
2
1
1
C-
M7-P03
M7-P05 M7-P06
TC-P01
TC-P02
TC-P03
TC-P02
TC-P04
TC-P03
SN2
SN24 4
2nd floor car call
TC-P04
CN3-P01 CN3-P02 CN3-P03 CN3-P04
4
3 ND2
E-CIB-A
TC-P01
E-KIB-A
BL2000-CEB M7-P01
+24V
3 JN2
2
JE2 2
>
1
+24V
ND24
J2
1
BL2000-ZLB SN16 4
GND
24V
C+
16th floor car call
C-
3 ND16
J1
C
BL2000-JDB Car Top PCB
+24V
JN16
SN25 4
2
>
1
J7
J1
ND25 C-
EB-P02
EB-P03
3
Door open button
CN3-P01 CN3-P02 CN3-P03 CN3-P04 EB-P01
4
C-
EB-P04
+24V
Over load
E-CIB-A
C+
GND
D C B A S
SN32
J2 4
2
3
1
Fire V+ V- E
BL2000-CEB
KM
Display board 24V
+24V
1 C+
GND
C
3 2
J1 24V
JE1
JE2 2 J2
X CZ MZ XF JX
+24V
ND32 1
GM 4 3
Door close button
+24V
J3
2 1
B 1
2
6
7
8
B
9 10 11 12 14 15 16 17 J5
BL2000-HXJ-V9
J1
J3
1
2
J2
3
4
1
YC 4
Door open prolong button Car LCD display transformer board
3 +24V
2 J4
J6
3
ZS
Bypass button
ZY
Special use button Fireman button
XFY
2
4
1
1
24V 1
GND 2
C+ 3
J5
C-
XFY 4
4
By attendant button
CN1 A
Car indicator
1
2
3
4
5
6
Design Check Approve
QianJianqiang
Date
2016.5.14
Car call loop
7
Draw No. Sheets Sheet Remark
TRF110 16 11
8
A
1
2
3
4
5
6
SJT-ZPC-V2A(VM1)
E-KIB-A JP1-1
M6-P01
+24V
24V
12
GND
11
11
K11
12
K14 11
21
K12
GND
DZ-P04
K10
JP1-2
M6-P02 D
8
7
D5
A2
K12
D
D1
61
64
GND
A1
12
K11 22
21
R1
K10 22
C1
Advanced door opening/releveling door zone switch
ZPS
K12
ZPS
DZ-P08
M6-P03
32
JP1-3
31
A1
K10 TB-P01
Up releveling door zone input
Advanced door opening/releveling relay output
COM0
M6-P07
44
M6-P02 Y0
ZPX
DZ-P09
M6-P04
D2
54
JP1-4
51
A1
K11 TB-P02
Down releveling door zone input
31
JP1-5
M6-P08
Y0
32
A2
K11 D3
K12 21
A1
22
Y0
A2
K14 D2
K14
Advanced door opening/releveling signal detection X22
A2
K10
K12
ZPX GND
41
M6-P05
JP1-6
42
K10
41
31
K11 32
41
42
X22
JP1-7
C
Releveling door zone input
M6-P06 X23
C
JP1-8
X23
JP1-9 K14 M6-P09
JP1-10
Door close lock M6-P10
JP1-14
Door close lock M6-P11
JP1-11
116
Optional function: Advanced door opening and Releveling
44
K10 43
61
12
54
K11 64
51
K14 54
51
54
Add for double entrances 117A
118B
B
B
JP1-12
K12 11
K10
K11 51
61
64
JP1-13
A
A
Design Check Approve Date
1
2
3
4
5
6
Draw No. JiangYongliang Advanced Door opening Sheets /Releveling ZhengYanfeng Sheet UCMP Remark 2016.5.14 QianJianqiang
TRF110 16 12
Optional function
7
8
1
2
3
4
5
6
JT-2000C
JT-04A1
IC card controller
IC card controller
J22 24+ 24-
8
7
J1
24+ 24- 1 2
OUT1+ 0UT1-
D
J8
3 -
4
1 2
3 -
+
4 +
D
EPSS-EPB36/110/220 24T GND1
24T GND1 DC12V output
Charging power input J2 J1
J3
J4
J5
J6
P6
P7
SN1
SN16 4 3
1st floor car call
ND1
-
+
4
JN16
JN1 2
100
101
BK0
BK2
M5-P02
M5-P03
M5-P05
16th floor car call
+24V
2
ND16 1
M5-P01
3
1
SN2 4
E-KIB-A
SN17 3
2nd floor car call
Power line DC12V
ND2 2
3
>
1
C
4
J1
J9
JN2
>
JE1 2
+24V
17th floor car call ND17
C
1
Video Cable
BL2000-ZLB
SN3
4 Controller LCD displayer
Shaft Traction Monitor
3
3rd floor car call
ND3
+24V
Note:
JN3
When JT-2000C is applied ,the connection of wire 3 &4 between extension card and IC card controller should be reverse. When JT-04A1 is applied, instruction on CZB board should be
2 1
connected to OUT1,instruction on extension board should be connected to OUT2.
Applicable for MRL Lift with EMK electric break release and machine monitor function SN8 4 3
8th floor car call
ND8
+24V
JN8 2 1
B
B
JL1
+
-
R
L
+
-
R
Car Inside
L
-
EB1EB2 +
R L
EA-P08
EA-P07
EA-P06
EA-P05
TA-P15 HD-P08
TA-P14 HD-P07
TA-P13 HD-P06
P+
TA-P12 HD-P05
EPS2-P06
G3-P04
L
EPS2-P05
G3-P03
TA-P15
R
EPS2-P04
G3-P02
-
Call
+
L
TA-P14
R
Guard room
Pit
EYJ
Alarm
EPS1-P01 EPS1-P02
EA-P12 EPS2-P01
EA-P09 EA-P10
YJ+ YJ-
-
G3-P01
P-
+
TA-P13
P+
EPS1-P05
+ EPS1-P09
EPS1-P07
EPS1-P08
EPS1-P06 EA-P11 EPS2-P02
JL+ JL-
L31 N1
-
+
EPS1-P04
-
+
Car top
M.R.
Intercom
TA-P12
E. Light
EPS2-P03
Emergency Power Box Alarm AC220V
PR
A
A
L
Single elevator intercom system
1
2
3
4
5
6
Design Check Approve
QianJianqiang
Date
2016.5.14
Draw No. TRF110 Intercom, 16 Sheets Optional Function Sheet 13 Remark
7
8
2
3
J1-4
J6-8 J6-7
J1-8
GND1
Lift A
J1-7
GND1
CB-
J6-2
J1-6
1L
CB+
J6-7
1H
BL6-U
J6-2
BL6-U 1H
J6-8
1H
1L
J6-7
1L
GND1
J6-2
GND1
Lift B
Lift H
CB+
+5V
D
CB-
N
BL6-U J6-8
8
7
GND1
J1-3
CB+
0V
CB-
L AC220V
N
6
BL2000-QKB
AVR2
(4A)
L3
5
GND1
F5
D
4
Group Control Board
1
C
C
Group control system circuit
AVR
200
L
+5V
4
AC220V
201
B
N
0V
BL6-U 2
Wired monitor and control system circuit:
GND1
BL20006 KIC/KID 3
J6 6
C+
9
5
C-
10
J1
B
SJT-QIC/QID YH
H
7
YL
L
J1 8
YG
G
Monitoring center
area communication cable RVVP(2*2)P*0.75 (One for each control cabinet)
Control cabinet Power supply AC220C
Note:Use one data collector for each monitoring system, it can monitor several elevators.
A
A
1
2
3
4
5
6
Design Check Approve
QianJianqiang
Date
2016.5.14
Draw No. TRF110 Optional Function 16 Sheets Sheet 14 Group control circuit Remark
7
8
1
2
3
4
5
6
8
7
Monitor Room Emergency Power Box E light
+
L
+
-
R
L
-
EB1EB2 +
NKT12(1-1)16N--59N Main
R L
AC AC
AD2
Call
AD1
+
-
D
EA-P08
EA-P07
EA-P05
EA-P06
From main intercom to pit of lift #1 RVVP5* 0.75
TA-P15 HD-P08
TA-P14 HD-P07
TA-P13 HD-P06
TA-P12 HD-P05
EPS2-P06
G3-P04
EPS2-P05
G3-P03
TA-P15
EPS2-P04
G3-P02
TA-P14
EPS2-P03
G3-P01
AL
+
A- AR
+ TA-P12
HD-P05 XDZ-P+
TA-P13
HD-P06 XDZ-P-
TA-P14
HD-P07 XDZ-R
TA-P15
HD-P08 XDZ-L
AL
AD1
AC220V
AD2
Adapter R1 L1
Car Top
Pit
A- AR
AL
AD1
AD2
L
+
Car
-
R
L
-
EB1EB2 +
C
R L
From lift #1 to pit of lift #2 RVVP 5*0.75
EA-P08
EA-P07
EA-P06
EA-P05
TA-P15 HD-P08
TA-P14 HD-P07
TA-P13 HD-P06
TA-P12 HD-P05
EPS2-P06
EPS2-P05
G3-P04 TA-P15
R
EPS2-P04
G3-P03 TA-P14
EPS2-P03
G3-P02
-
Call
+
L
G3-P01
P-
R
TA-P13
P+
-
TA-P12
+ EPS1-P05
EPS1-P04
-
P+ P-
EYJ
EA-P12 EPS2-P01
Alarm
+ EPS1-P09
EA-P09 EA-P10
EPS1-P08
EPS1-P07
EPS1-P06
R
E. Power
Intercom
-
EA-P11 EPS2-P02 JL1
TA-P13
P-
MR.
E light
+
YJ+ YJ-
L31 N1
-
P-
JL+ JL-
EPS1-P01 EPS1-P02
+
L
L
-
+
R
R
Alarm AC220V
-
TA-P12
P+
Emergency Power Box C
Car
A- AR
EYJ
Alarm
JL1
-
P+ EA-P12 EPS2-P01
L31 N1
EPS1-P01 EPS1-P02
+ EPS1-P09
YJ+ YJ-
EA-P09 EA-P10
EPS1-P07
EPS1-P08
EPS1-P06 JL+ JL-
EA-P11 EPS2-P02
D
Pit
Intercom
-
+
EPS1-P05
-
EPS1-P04
Alarm
+
AC220V
Car Top
MR.
A- AR
+ TA-P12
HD-P05 XDZ-P+
TA-P13
HD-P06 XDZ-P-
TA-P14
HD-P07 XDZ-R
TA-P15
HD-P08 XDZ-L
AL
AD1
AD2
R
Adapter R1
L
L1
A- AR
AL
AD1
AD2
B
B
From lift #2 to pit of lift #N RVVP5* 0.75
Emergency Power Box
R
+
L
-
R
L
+
Car
-
R
L
-
EB1EB2 +
R L
Call
P-
3
4
AD2
R L
EA-P08
EA-P07
EA-P06
1. Cable is RVVP 5*0.75
Adapter
TA-P12
HD-P05 XDZ-P+
TA-P13
HD-P06 XDZ-P-
TA-P14
HD-P07 XDZ-R
TA-P15
HD-P08 XDZ-L
5
2. Single bus should not bifurcation or star wiring 3. Intercom should be connected to its own adapter
A- AR
R
2
AD1
Intercom bus cable by others and layout should be reasonable
L
1
AL
+ -
EA-P05
TA-P15 HD-P08
TA-P14 HD-P07
TA-P13 HD-P06
TA-P12 HD-P05
EPS2-P06
EPS2-P05
EPS2-P04
EPS2-P03
G3-P04 TA-P15
G3-P03 TA-P14
TA-P12
P+ EYJ
Alarm
-
G3-P02
P-
EA-P09 EA-P10
EA-P11 EPS2-P02 JL1
EA-P12 EPS2-P01
A
Pit
A- AR
YJ+ YJ-
JL+ JL-
EPS1-P01 EPS1-P02
+
G3-P01
P+
L31 N1
-
TA-P13
+ EPS1-P09
EPS1-P08
EPS1-P07
EPS1-P06
-
+
Car Top
Intercom
EPS1-P05
-
+
AC220V
MR.
E light
EPS1-P04
Alarm
6
AL
AD1
AD2
Design Check Approve
QianJianqiang
Date
2016.5.14
Optional Fuction NKT12 Intercom (bus connection)
7
TRF110 16
Draw No. Sheets Sheet Remark
15
8
A
1
2
3
4
5
6
8
7
Monitor Room Emergency Power Box E light
+
R
+
L
R
-
L
+
Car
R
-
L
-
EB1EB2 +
R L
Call
TA-P15 HD-P08
EA-P08
EA-P07
EA-P06
EA-P05
TA-P14 HD-P07
TA-P13 HD-P06
TA-P12 HD-P05
EPS2-P06
G3-P04
EPS2-P05
G3-P03
TA-P15
EPS2-P04
G3-P02
TA-P14
EPS2-P03
G3-P01
TA-P13
HD-P06 XDZ-P-
TA-P14
HD-P07 XDZ-R
TA-P15
HD-P08 XDZ-L
R1
Pit
+
L
Car
-
R
L
C
-
EB1EB2 +
R L
EA-P08
EA-P07
EA-P06
EA-P05
TA-P15 HD-P08
TA-P14 HD-P07
P+
TA-P13 HD-P06
TA-P12 HD-P05
EPS2-P06
EPS2-P05
G3-P04 TA-P15
R
EPS2-P04
G3-P03 TA-P14
EPS2-P03
G3-P02
-
Call
+
L
G3-P01
P-
R
TA-P13
P+
-
TA-P12
+ EPS1-P05
EPS1-P04
-
P-
EYJ
JL1
+ EPS1-P09
EA-P09 EA-P10
EPS1-P08
EPS1-P07 Alarm
L31 N1
EA-P12 EPS2-P01
YJ+ YJ-
EA-P11 EPS2-P02
EPS1-P06 JL+ JL-
EPS1-P01 EPS1-P02
Car Top
Intercom
-
+
L1
MR.
E light
-
+
AC AC D
P-
Emergency Power Box AC220V
-
AC220V
R
Alarm
+
-
E. Power above 32 by others
L
C
E. Power
+
NKT12(1-1)6A--64A(Main)
TA-P13
P-
-
TA-P12
P+
-
EYJ
JL1
Pit
P+
EA-P12 EPS2-P01
Alarm
L31 N1
EPS1-P01 EPS1-P02
+ EPS1-P09
YJ+ YJ-
EA-P09 EA-P10
EPS1-P07
EPS1-P08
EPS1-P06 JL+ JL-
EA-P11 EPS2-P02
D
Car Top
Intercom
-
+
EPS1-P05
-
EPS1-P04
Alarm
+
AC220V
MR.
TA-P13
HD-P06 XDZ-P-
TA-P14
HD-P07 XDZ-R
TA-P15
HD-P08 XDZ-L
R
R2
L
L2
B
B
Intercon bus cable instruction: Emergency Power Box E light
JL1
Pit
L
1. Each elevator has one separate cable connecting to monitor room
Car
R
-
L
-
EB1EB2 +
R L
TA-P15 HD-P08
R1
EA-P08
EA-P07
EA-P06
L1
EA-P05
TA-P14 HD-P07
TA-P13 HD-P06
TA-P12 HD-P05
2. Cable is RVVP3* 0.75
-
Call
+
EPS2-P06
EPS2-P05
EPS2-P04
G3-P04 TA-P15
R
-
EPS2-P03
G3-P03
L
TA-P14
R
G3-P02
P-
-
G3-P01
+
+
TA-P13
EPS1-P09
-
TA-P12
P+
P-
EYJ
A
+
P+ EA-P12 EPS2-P01
Alarm
YJ+ YJ-
EA-P09 EA-P10
EPS1-P08
EPS1-P07
EPS1-P06 JL+ JL-
EA-P11 EPS2-P02
L31 N1
EPS1-P01 EPS1-P02
Car Top
Intercom
-
+
EPS1-P05
-
EPS1-P04
Alarm
+
AC220V
MR.
TA-P13
HD-P06 XDZ-P-
TA-P14
HD-P07 XDZ-R
TA-P15
HD-P08 XDZ-L
R L
1
2
3
4
5
6
Design Check Approve
QianJianqiang
Date
2016.5.14
A
Optional Fuction NKT12 Intercom (line connection)
7
TRF110 16
Draw No. Sheets Sheet Remark
16
8
1
2
3
4
5
6
7
8
200
Top Final Switch
D
SSJ D
100
Top Limit Switch
SXV
Top Terminal Switch
SDZ1
Sub Top Terminal Switch
SDZ2
*1
*2 200
Bottom Final Switch
SXJ
Bottom Limit Switch
XXV
100 C
C
Sub Bottom Terminal Switch
XDZ2 *2
Bottom Terminal Switch
XDZ1 *1
MQ Leveling Position
Leveling Zone switch
SMQ
standard elevator
XMQ
Car
H1
(Unit:mm ) Shelter Board H2 UP B
B
XMQ
ZPX
advance door open and releveling function
ZPS
SMQ
DOWN
MQ Leveling Position
Car
H3
Shelter Board H4 UP
A
Elevators have to finish hoistway learning before high speed running. The conditions below are necessary before hoistway learning. 1.Top/bottom limit switch and top/bottom terminal switch are installed, connection is correct. 2.Up/down leveling zone switch and shelter board are installed, connection is correct. 3.Safety circuit and door interlock circuit are normal. 4.General parameters and running parameters have been set. 5.Elevator can perform inspection running.
1
2
3
DOWN
Speed Item *1 *2 H1 H2 H3 H4
4
0.5m/s
1.0m/s
1.6m/s
1000
1300
2300
180 200 280 300
180 200 280 300
180 200 280 300
5
2.0m/s
2.5m/s
2300 4000 180 200 280 300
2300 6250 180 200 280 300
6
Design Check Approve
QianJianqiang
Date
2016.5.14
Draw No. TRF110 18 Hoistway Signal Sheets 1 Sheet Installation Remark
7
8
A
1
2
1
2
3
4
5
3
1
2
118A
11
GB2
10
GB1
9
114A
8
PE
7
2 2
7
39 40
8
2
3
4
5
6
6
1
1 2
2
3
4
8
9
10
11
12
6
7
8
9
Input/Output Terminal Table
10
Main Board IndicatorName XF(X12)
CN1
WK(X21) CZ(X25)
GND GND+24V X13 X14 X20
S5
13
1
116 117A118B GB1 GB2
2
3
4
5
JX
Normal inspection signal
X1
MS
Up Running Signal
TA/7 M3/3
X2
MX
Down Running Signal
TA/8 M3/4
X3
119
Up Terminal 2 Signal
HA/2
X4
120
Bottom Terminal 2 Signal
HB/2
X5
121
Spare
HA/5
X6
122
Spare
HB/5
X7
123
Up Terminal 1 Signal
HA/3
X8
124
Bottom Terminal 1 Signal
HB/3
X9
SMQ
Up door zone
TA/9
X10
XMQ
Down door zone
TA/10
X11
X11
X12
XF1
JR1
X13
X13
Emergency contactor Signal
G5/7
JR2
X14
X14
Door lock Feedback Signal
G5/8
M7
135 136 +24V DMS(X1)
7
8
MS(X1) DMX(X2) MX(X2)
HF
9
3
1
5
6
7
+24V+24VGNDGND C+
C-
COM5
1
130B JX(X0)
2
3
4
8
9
10
11
12
Y11 COM4 Y10 LD1(COM1) LD2(Y1)
130A 130
110 110A HE1
PE
4
115C
3
115C
116
PE
HB
117
3
RB
1
3
1
120
123
GND 122
PE
109
108
GND
9 PE
10
HA
124
114
136
12
7
JR0
119 121
PE
TC
114
113
24V
9
7
HC 24V
1
S2
JR11
S3 S4
JR10
1
COM2
1
Y2
2
M4 Y3
3
Y4
4
Y5
114A
GND
GND
C+
C+
5
X15
C 11
118B
10
118
CHE2 PE
118
116
7
115A
6
108
C5
CANPE
CANPE
JR4
5
JR5
GND
JR6
5
100(IN)
4
122(X6)
3
121(X5)
2
130A
1
GND
3
4
L
3
R
HD
110 117A
108 117
1
100
P+
3 GB1 1
118
P-
L35
130 XMQ R
P-
1
3
109
BYX
ZPX ZPS
201
200
3
1 KBK1
GND
JR8
BK3 BK2 BK1
R
N1
L31
6
PE
9
N2
RA KBK2
115B
L
4 L
P+
JR7
TB
1 115A 113
S8
GB2A
SMQ DMX DMS
15
B
TD
TA D1
4 JR9
7
10
13
G3 2
P-
1
P+
M1
G6
F1
E-KIB-A_V1
N2
Light fan fuse protector 1
5
L35 PE 4
3
N1 2
L31 1
9
8
7
6
5
4
3
2
2
X17
X17
Brake Contactor Signal
M2/8
Y8
3
X18
YJ
Emergency Leveling Signal
G4/4
Y9
4
X19
KBK2 Right Brake arm feedback Signal
5
X20
X20
118A
6
X21
WK
Temperature control/seismic signal
101
7
X22
X22
Releveling condition Signal
M6/5
M2 X17
8
X23
X23
Releveling sensor Signal
M6/6
X16
9
X24
XF2
Fire Linkage Signal
G5/10
X11
10
X25
CZ
Over load signal
G5/3
GND
11
Y0
300
12
COM0
301
13
Y1
BK0
14
COM1
BK2
15
Y2
BYX 118B
1
9
8
COM2
116 BK3 BK2 BK1 BK0 101 7
6
5
4
3
2
Y3 COM2
1
S1
Commu nication earthed:Left side earthed and right side connect to power(-)
Left side
S2-S8
Spare
Bridge joint
Name
Y8
Y8
Definition Star shorted contactor
COM3 Y9
COM3
COM3 Y10
Y11
1
2
3
4
Y7
M2/5
COM3
M2/5
Y10
M7/10
COM4
M6/8 Previous Door Opening Relay M6/7 COM0 M7/12 LD2 Fire Linkage Relay M7/11 LD1 Y0
Spare output
M4/1
COM2
M4/3
Y3 Spare output
M4/1
COM2
M4/4
Y4 Spare output
COM2
M4/1 M4/5
Y5 Spare output
COM2 Y6
B
M4/2
Y2
M4/1 M2/1
Economic resistor contactor
COM3
M2/5 M2/2
Y7 Brake contactor
M2/5
COM3
A
M7/9 M7/8
Y11 Spare output
COM5
M2/3
COM3 Spare output
COM4
COM3
G5/2
M2/4
Y9 Running contactor
A
Y6
Interface board position No.
RA/3
G5/9
Electric lock signal
100(IN)
Input & output terminal comparison table Main board indicator light
C
M2/9
Running Contactor Signal
COM3
COM2
Factory setting
RA/2
Y7
Y5
Definition
KBK1 Left Brake arm feedback Signal X16
COM2
Jumper wire and bilateral switch
G5/1
X16
Y4
Name
D
M2/10
Fire Signal
1
M5
100 101 200 201 300 301 141 116 +24VGND 10
Star shorted contactor signal
Y6
PE 12
M3/2
JR3
NC
117
8
S1
PE
118B 9
Interface Board Location No.
X0
S6
6
Definition
XF(X24)
G5 M8
7
5
8
7
135 GND MX
115 G2
PE
6
MS
5
115B
5
5
130A130B MS(X1)MX(X2)110A 115 115A 141
+24VGND ZPS ZPX X22 X23 COM0 Y0
6
1
4
M6 1
115
2
3
M3
118B
12
1
G4
G1 13
4
141 116 GND YJ(X18)
116 117 118 118A 101 D
3
4
COM5
5
M7/7
6
Design Check Approve
QianJianqiang
Date
2016.5.14
Control Box Interface Board Plug-in Drawing
7
Draw No. TRF110 18 Sheets Sheet 2 Remark
8
1
2
3
4
5
6
G4 1 141 2 116 3 GND 4 YJ(X18)
D
J1
Main Control Board
C
J7-5 J7-2 J7-x J7-4 J7-1
High-platform (Main motor) Emergency Stop
B
Hand-wheel Switch
Up Run Overspeed Switch
Intercom
A
1
2
EPS13
2 3
Emergency Leveling Device D
4
G1 116 117 118 118A 101
1 2 3 4 5
G2 115b PE 115C 115C PE 115 115 PE 114a GB1 GB2 118A 118B
1 2 3 4 5 6 7 8 9 10 11 12 13
G3 P+ PR L
1 2 3 4
Fire Signal Temperature control signal Overload Signal
RA 1 GND 2 KBK1 3 KBK2 4 BK1 5 BK2 6
40pin bull socket
BL6 VER:1.0
1
G5 1 XF(X12) 2 WK(X21) 3 CZ(X25) 4 GND 5 GND 6 +24V
CN1
8
7
Brake Inspection
C
Brake
RB 1 114A 2 PE 3 114
Speed Governor Down Run Protection Switch
Interface Board E-KIB-A VER:2.0 1 2 3 4 5
G6 L31 N PE L35 N2
B
Car Light Power Input
D1 1 GND 2 130A 3 121(X5) 4 122(X6) 5 100(IN) 6 108 7 115A 8 116 9 117 10 118 11 118B
3
4
5
A
6
Design Check Approve
QianJianqiang
Date
2016.5.14
Control Box Wiring Terminal Circuit
7
Draw No. TRF110 18 Sheets Sheet 3 Remark
8
1
2
3
4
5
6
1 2 3 4 5 6 7 8 9
M1 GND 24V 116 141 300 301 201 200 101 100 M2
D
DC24V Power Input Phase Relay Safety Circuit Brake Power Input 220V Power supply for control circuit AC110V Power input
C
1 2 3 4 5 6 7 8 9 10
1 Y6 2 Y7 3 Y8 4 Y9 COM3 5 118 6 101 7 X17 8 X16 9 X11 10 GND 11 300 12 301 13 BK0 14 BK2 15
Running, Brake, Star shorted Contactor coil
Contactor adhesion inspection
Brake circuit
E-KIB-A VER:2.0
M3 130A 1 130B 2 MS(X1) 3 MX(X2) 4 110A 5 115 6 115A 7 141 8
B
Controller Inspection Box
M5 100 101 BK0 BK1 BK2 BK3 116
Brake-releasing 110V charging D
Brake power for brake release device
Door lock spare
118B BYX
Spare 1
M6 1 24V 2 GND1 3 ZPS 4 ZPX 5 X22 6 X23 7 COM0 8 Y0 9 116 10 117A 11 118B 12 GB1 13 GB2
Interface Board
118
8
7
Previous Door Opening Board Power Previous Door Opening/Releveling Zone input Previous Door Opening/Releveling Signal Inspection Releveling Zone Signal Input
C
Previous Door Opening Zone input
Door lock signal
Car door close inspection
M7 1 24V 2 24V 3 GND 4 GND 5 C+ 6 C7 COM5 8 Y11 9 COM4 10 Y10 11 LD1 12 LD2
Power supply communicate to main board B
Spare Spare Fire Linkage Output
A
A
1
2
3
4
5
6
Design Check Approve
QianJianqiang
Date
2016.5.14
Control Box Plug-in Circuit
7
Draw No. TRF110 18 Sheets Sheet 4 Remark
8
1
2
3
4
5
6
7
8
Control cabinet
D
D
1 2 3 4
Power input
Traction motor
PG-A2/E
DDZ U1 1 V1 2 W1 3 Note:Power supply for MRL is L1,L2,L3 N 4 PE 5
C
DDZ U3 V3 W3 PE
Encoder C
1 2 3 4 5
XDZ L32A L32B 201 XS1 XS2
Shaft light
MRL speed governor detection
B
B
A
A
1
2
3
4
5
6
Design Check Approve
QianJianqiang
Date
2016.5.14
Draw No. TRF110 18 Sheets Sheet 5 Terminal Circuit Remark
Control Box
7
8
1
2
3
4
5
6
8
7
D
D
1
2
3
4
+24V GND C+
C-
1
2
3
4
1
+24VGND BL1 BL2
CHM
2
3
4
5
6
7
GB1 GB2A BYX BY01 BY02117A 118
VB
8
9
S2
3 PE
GND +24V QZ
2
L31 N1
3
4
PE
P+
5
6
7
8
9
1
JL+ JL- YJ+ YJ-
P-
3
4
5
6
JL1 JL- P+
P-
R
L
EPS2
EA
TD 12
L31
N1
YJ-
JL+
JL1
200
201
R
L
YJ+
4
BZ
FA
ZPS ZPX BYX
JR1
1
P+
P-
N2
L33
105
CANPE
GND
C-
12
12
3
RDR
EM 3
1
GND
+24V
3
DR
GB1
6 ZM/FS 3
3
DMX
4
105
5
106
6
118
117 117A
111
7
100
108
110
8
110
PE
201
GND
200
LSB2_1
10
PE
LSB1_1
1
10
3
12
3
RGS
GS 117A
PE
PE
117A
201
EM
FA
PE
PE
200
N1
N1
118
117
SOS
RTES
108
111
KAB1
KAB2
1
7
P+
1
3 C+
2
DMS
L
DMS DMX SMQ
GB2A
E-CIB-A_V1
PE
R
XMQ 130
L35
P-
1
EB
1
130 15
3
CN1
100
GND TA 13
JR2
3
9
2
EPS1
10
9 PE
CZ
1
1
5
L35 N2
TB
JR0
C
4
VA
7
9 MZ
2
L31 N1
QGM1QGM2
BY
LWD 7 S3
1
4
1
C
CIB
1
CN2
B 12 TC
5 CN3
CANPE
C-
C+
HF
GM2 GND PE
1 GND 24V
GB
KM2
GMV2
201
CM2
KMV2 GB2A
200
10
S1 1
DM
3
9
DZ
3
GM GND PE
GB1
ZPX SMQ XMQ
KM
GMV1
201
ZPS +24V
PE
PE
CM1
KMV1
200
GND
111
106
10
GB
7
1
B
1
Jumper wire Definition
Factory setting
S1
Spare
Bridge joint
S2
Spare
Disconnect
S3
Spare
Disconnect
Name A
1
2
3
A
4
5
6
Design Check Approve
QianJianqiang
Date
2016.5.14
Draw No. TRF110 Car Top Interface Board 18 Sheets Sheet 6 Plug-in Cable Remark
7
8
1
2
3
CB0
HA
CB1
HB D
Control Cabinet E-KIB-A
CB2
HC
CB3
HD
CB4
HE1
CB5
TB
CB5
TA
HE2 TD
TC
CB5
TB
6
8
7
Hoistway Top Signal Cable Hoistway Bottom Signal Cable Hoistway Communication Cable
D
Pit Cable Front landing door Lock Cable Rear landing door Lock Cable
CB5
TC
5
Junction Box on Car Top
TD
RGS
COP Cable
CB9 CB10
TA
CB4b
4
C
DB5
SMJ C
RTES
EA
DB4
RDR
Rear Door Lock
DB8 DB8A
SDH
E-CIB-A Car Top Wiring
Rear Door Emergency Stop
EB
KAB2 Rear Door Light Curtain Box
LWD
DB1
DB7 DB7A
DB10
MZ
3
CZ
FAN
EM
Light Fan Leveling Zone and Previous door opening
2
DB11
DB10A
Light Curtain Box
Front Door Lock
A
1
DB9
MQ
KAB
SMJ
SNQ Safety Gear
DB2
CMM
CM1 KM2 GM2
GMV2
200 201 PE
DB3A
DB6
L N PE B2 B3 C2,C3 8 1 2
DB3
B
DB6A
L N PE B2 B3 C2,C3 8 1 2
B
CMM
LWD
CM1 KM GM
ZM/FS
GMV1
DZ
KMV1
DR
200 201 PE
GS
KMV2
RDM
DM SOS
U V W
U V W
DM
DM
Weight Switch A
4
5
6
Design Check Approve
QianJianqiang
Date
2016.5.14
Machine Room & Car Top Circuit
7
Draw No. TRF110 18 Sheets Sheet 7 Remark
8
1
2
3
4
5
6
7
8
EPS1
J4 D
L31 N PE
CN1
D
Car Top PBC BL2000-JDB
2 P+ PJL+ JLYJ+ YJ-
Intercom Power Input 1 J3
Intercom Power Input 2 Alarm Power Input 1 Alarm Power Input 2 Emergency Light Power Input 1 Emergency Light Power Input 2
CN2
4
4 CN3
J1
3 4 5 Car Top Emergency Power 6 7 8
1
1
EPS2 JL1 JLP+ PR L
C
P+
P+ PR L
PR L
EDM XD
SDM
VA L31 N1 PE
L31 N PE
VB 24V GND BL1 BL2
DZZ Power 1 DZZ Power 2 DZZ COM DZZ Output
BELL
Car Top Motor
1
Alarm Wiring Terminal 1 Alarm Wiring Terminal 2 Intercom Power Intercom Power Intercom Signal 1 Intercom Signal 2
Interface Board E-CIB-A
Car light socket
L35 N2
BY GB1 GB2A BYX BYO1 BYO2 117A 118 QGM1 QGM2
24V GND
Arrival Gong
T1 T2
C
Front car door close detection
KGB1 KGB2 Rear car door close detection
Bypass buzzer (Optional)
Rear door lock signal
DJ
B
B
11
12
13
14
130
21
22
DMS
DMG
DMS
CIB GND 130 DMS DMX
GND
DMX
DMX
Signal COM Inspection Signal Inspection Up Signal Inspection Down Signal
CHM 24V
24V
Voice Announcement GND C+ C-
GND C+ C-
Voice Announcement
SDT Car Top Emergency Stop 105
105 106 111 110
106 111 110
Car Top Emergency Stop 1 Car Top Emergency Stop 2 Car Top Inspection 1 Car Top Inspection 2
A
A
Design Check Approve Date
1
2
3
4
5
6
Draw No. TRF110 Car Top 18 Sheets 8 Sheet Interface Board Terminal Remark 2016.5.14
QianJianqiang
7
8
1
2
3
4
5
6
7
8
The definition of interface board and plug-in branch cable D
Plug (194017-1)
Car Top Interface Board
3m 2
Safety Gear Cable DB1 2 3*0.75mm (L=3m)
Plug SOS 1-480700-0
Pin
Wire No. in Drawing
3*0.75mm 3
1
111
2
Cable No.
SOS
1 2
111 PE
1 3
1
3
108
2
AMP 1-480700-0
2
PE
3
108
111
1
D
DB1
3
PE
2
108
SOS
3m 2
Plug (194017-1)
Car Top Interface Board
3*0.75mm 3
Front Door Lock Cable DB2 2 3*0.75mm (L=3m)
Plug GS 1-480700-0
Pin
Wire No. in Drawing
1
117
2
PE
2 GS 1
Cable No.
1
117
1
2
PE
3
3
117A
2
3 117A
117
1
DB2
3
PE
2
117A
GS
AMP 1-480700-0 3m Freight elevator rear door cable length add to 6m 2
3*0.75mm 3
Plug (194017-1)
Car Top Interface Board
C
RGS 1-480700-0
118
RGS 2
PE
2
Rear Door Lock Cable DB5 2 3*0.75mm (L=3m)
Plug
1
1 3 117A
Pin
Wire No. in Drawing
1 2
118 PE
1 2
3
117A
3
3m Freight elevator rear door cable length add to 6m 1
1
Plug (194017-1)
Car Top Interface Board
2
106
Pin
Wire No. in Drawing
1 2
106 PE
1 3
3
111
2
Plug (194014-1)
Car Top Interface Board A
111
111 200
Cable No.
1
200
2
201
3
2
1
6
PE
6
5
4
3
GB1
4
GB
9
8
7
12
11
10
Wire No. in Drawing
1
200
1
2
201
2
3
GB1
1
10 CM1
4
GB
2
11 KM
5
Empty
6
PE
3
7
KMV1
1
8
GMV1
7 KMV1
DM DM
AMP 1-480708-0
8 GMV1 9 GND
12 GM
9
GND
2 3
10
CM1
4
11
KM
5
12
GM
6
201
2
Pin
2
PE
2
3m
DB3
1
PE
B
2 3
KMV1
1 2
GMV1
3
GND
4
DB3A
5
CM1
6
KM
2
6*0.75mm
GM
3m A
QianJianqiang
2. Both ends of stripped-off cable length is 100mm, and cover number tube.
Design Check Approve
3. Cable plug-in is equipped with 350536-1 jack.
Date
2016.5.14
Note:1. Add DB4,DB5 cable for double entrance, freight elevator rear door cable length add to 6m.
type 7508 1
DB4
3
3*0.75mm
2
1-480708-0
PE
3
AMP 1-480700-0
Cable No.
3*0.75+6*0.75mm (L=3m)
DM
RTES 2
106
1
RTES
Front Door Operator Cable DB3 DB3A
Plug
117A
2
3*0.75mm (L=3m)
B
2
3*0.75mm 2
1-480700-0
PE
AMP 1-480700-0
Rear Door Emergency Stop Cable DB4
RTES
C
DB5
3
RGS
Cable No.
3
Plug
118
1
3
4
Draw No. TRF110 18 Sheets Car Top Interface Board 9 Sheet Plug-in Cable Remark
type 1.25-3 5
6
7
8
1
2
3
4
5
6
7
8
The definition of interface board and plug-in branch cable 3m Freight elevator rear door cable length add to 6m 2
Rear Door Operator Cable DB6 DB6A
3*0.75mm
2
3*0.75+6*0.75mm (L=3m)
D
Plug (194014-1)
Car Top Interface Board
Plug
RDM 1-480708-0
Pin
Wire No. in Drawing
Cable No.
1
200
1
2
201
2
3
GB
4
GB2A
5
Empty
6
PE
7 8
1
200
4
2
201
3
2
1
6
5
9
8
7
6
PE
12
11
10
3
GB
RDM
AMP 1-480708-0
3
7 KMV2
9
GND
1
10 CM2
GMV2
11 KM2
9
GND
10
CM2
4
11
KM2
5
12
GM2
6
DB6
201
DB6B
PE
4 GB2A
KMV2
2 3
D
2
RDM 8 GMV2
3
200
1
12 GM2
1 2
KMV2
3 4
GMV2
5
GND
6
DB6A
2
CM2
6*0.75mm
KM2 GM2
C
C
Front Door Light Curtain Cable DB7 DB7A 2
3*0.75+2*0.75mm (L=3m)
Plug (194014-1)
Car Top Interface Board
Plug
DR 1-480708-0
B
Pin
Wire No. in Drawing
Cable No.
1
200
1
2
201
2
3
Empty
4
Empty
5
PE
6
Empty
7
Empty
8
GND
9
KAB1
10
Empty
11
Empty
12
Empty
3m Freight elevator rear door cable length add to 6m 2
3*0.75mm 3
3
2
1
200
6
5
4
2
201
9
8
7
DR 5
PE
12
11
10
8 GND
DR
1 2
1
9 KAB1
1
Plug (194014-1)
Car Top Interface Board A
RDR 1-480708-0
6
KAB1
3m Freight elevator rear door cable length add to 6m
3m Freight elevator rear door cable length add to 6m
Cable No.
3
2
1
1
200
1
6
5
4
2
201
2
201
2
9
8
7
RDR 5
PE
3
Empty
12
11
10
4
Empty
5
PE
6
Empty Empty GND
9
KAB2
10 11
Empty Empty
12
Empty
2
B
2
3*0.75mm
200
8
GND
DB7A
2
2*0.75mm
1
7
PE
5
2
Wire No. in Drawing
201
3
AMP 1-480708-0
3*0.75+2*0.75mm (L=3m)
Pin
DB7
2
Rear Door Light Curtain Cable DB8 DB8A
Plug
200
1
8 GND
RDR
9 KAB2
DB8
2
201
3
PE
5 6
GND
DB8A
2
2*0.75mm
AMP 1-480708-0
3
200
1
KAB2
3m Freight elevator rear door cable length add to 6m A
1 2
Note:1. Add DB6, DB6A, DB8, DB8A cable for double entrance, freight elevator rear door cable length add to 6m. 2. Both ends of stripped-off cable length is 100mm, and cover number tube. 3. Cable plug-in is equipped with 350536-1 jack.
Design Check Approve
QianJianqiang
Date
2016.5.14
Draw No. TRF110 Car Top Interface Board 18 Sheets 10 Plug-in Cable Sheet Remark
type 7508
3
4
5
6
7
8
1
2
3
4
5
6
8
7
3m GND
The definition of interface board and plug-in branch cable
24V SMQ D
D
GND
Leveling Zone Cable DB9 2 6*0.5mm (L=3m)
Plug (194012-1)
Car Top Interface Board
Plug
Wire No. in Drawing
1
Empty
3
2
1
2
Empty
6
5
4
9
8
7
3
DZ 1-480706-0
2
6*0.5mm
Pin
4 5 6
Cable No.
XMQ
4
GND
1
24V
2
4 GND
DZ
AMP 1-480706-0
DZ 5
24V
6
SMQ
8
ZPS
9
ZPX
24V ZPS
2
DB9
3
GND
4 5
24V
6
ZPX
3
SMQ Empty
7
3 XMQ
1
GND
ZPS 、ZPX for advanced door opening or relevelling.
8
ZPS
5
9
ZPX
6
24V XMQ
C
C
3m
Plug Plug (194002-1)
Car Top Interface Board
Light Fan Cable DB10 DB10A 2 3*0.75+3*0.75mm (L=3m)
Pin
2
3*0.75mm
Wire No. in Drawing Cable
1
N1
1
2
FA
2
ZM/FS
3
PE
3
1-480704-0
4
N1
5
EM
6
PE
3
B
No. 3
2
1
6
5
4
1 2
N1 FA
3
PE
4
N1
1
5
EM
2
6
PE
ZM/FS
ZM/FS
AMP 1-480704-0
N
1
DB10
2
FA
3
PE
1
N
2 3
DB10A
2
3*0.75mm
EM B
PE *2
3m
*1:No need to make the chuck.
Over Full Load Cable DB11 2 3*0.5mm (L=3m)
Plug (194012-1)
Car Top Interface Board
Plug
Pin
Wire No. in Drawing
1
Empty
2
Empty
3
Empty
4
LWD 1-480706-0
GND
5
1
24V Empty
6 7 8
A
Cable No.
9
MZ
2
CZ
3
3
2
1
6
5
4
9
8
7
3*0.5mm 4 GND
LWD
AMP 1-480706-0
LWD 7
MZ
8
CZ
GND
1
DB12
2
MZ
3
CZ A
Empty
1. Both ends of stripped-off cable length is 100mm, and cover number tube.
Design Check Approve
QianJianqiang
Draw No. TRF110 Car Top Interface Board 18 Sheets Sheet 11 Plug-in Cable Remark
Date
2016.5.14
type 1.25-3
1
2
3
4
5
6
7
8
1-480706-0
Top Terminal 2
Top Terminal 1 2 Olivine Earthing 3 Top Limit
121
4 5
GND 113 114
COM Top Final Limit
6
114 113 SSJ Top Final Limit PE 121 GND SXV Top Limit 123 GND SDZ1 Top Terminal 1 119 GND SDZ2 Top Terminal 2 To be connected when speed ≥2.0m/s
118b NKTM E
Hoistway Cable CB1 2 6*0.75+1*1.5mm Plug
Pin
1 2 3 4 5 6 7 8 9
Control Box
C
HB 194012-1
Wire No. in Drawing
HB 1-480706-0
1 2
120 124 PE 122
Definition
Cable No.
2KTM 1KTM E
Bottom Terminal 2 Bottom Terminal 1
1KTM 118 E
Olivine Earthing 3 Bottom Limit 4 5 6
GND 108 109
Wire No. in Drawing
117 PE 116
1 2 3
HE1 1-480700-0
COM Limit
116 NKTM E
Cable No.
Definition
1 Olivine 2
Landing Door Lock
2KTM 1KTM E 1KTM 117 E
HE2 1-480700-0
Wire No. in Drawing
118 PE 118b
1 2 3
Door Interlock on F2
Door Interlock on F1
Cable No.
Definition
1 Olivine
Landing Door Lock
120 GND XDZ2 Bottom Terminal 2 To be connected when speed ≥2.0m/s 124 GND XDZ1 Bottom Terminal 1 122 GND XXV Bottom Limit 108 109 SXJ Bottom Final Limit PE
2
2
3
1
6
5
4
9
8
7
2 1
HA/HB
AMP 1-480706-0 1
Terminal 2 branch 6m Terminal 1 branch 5m Limit branch 3m Final limit branch 3m
Electric lock
A 3
B
Bottom door lock branch line 3m
XF
Pin
Door Interlock on FN
Fireman switch 1
HE 194017-1
Control Box
Hoistway Cable CB4b 2 2*0.75+1*1.5mm Plug
C
Door Interlock on F1
2.3m
HE 194017-1
Control Box
B
Pin
Door Interlock on F2
HE1/HE2
Design Check Approve
QianJianqiang
Date
2017.2.24
Draw No. TRF110 18 Sheets Hoistway Pit Circuit Sheet 12 (with limit) Remark
AMP 1-480700-0 2
3
4
D
Final limit branch 3m Limit branch 3m Terminal 1 branch 5m Terminal 2 branch 6m
Bottom Final
Hoistway Cable CB4 2 2*0.75+1*1.5mm Plug
Door Interlock on FN
Top door lock branch line 3m
LR Cable length of M.R.
1
7m for MR, 5m for MRL
Definition
LH Hoistway total height
HA
119 123 PE
Cable No.
1 5 9
PP
Control Box
HA 194012-1
D
Wire No. in Drawing
1 2 3 4 5 6 7 8 9
G5
1 2 3 4 5 6 7 8 9
GND
Pin
2
HA Hoistway Top Cable
HE2 1 2 3
8
7
X20
Plug
HE1 1 2 3
HE1 Front Landing Door Lock Cable
Hoistway Cable CB0 6*0.75+1*1.5mm
1 2 3 4 5 6 7 8 9
6
LT Overhead height-2.3m
HB Hoistway Bottom Cable
5
Floor height of N-1
4
Floor height of N-2
3
This cable use spare cable. Add it when there is two-circuit detection.
2
HE2 Rear Landing Door Lock Cable
1
5
6
7
8
A
1
2
3
4
5
6
8
7
PB3=5M
PB1=2M
PB2=3M 115e
Emergency Stop Rope Breakage Cable PB1 PB2 HD 109
P+
115b
L
R
PE PE
115d 115e 115b 115d
E-PIB-A PC-2
PE
PE
112
109
PE
113
112
8
9
10
11
L35 N2 PE 115e 115a 109 113 P+ P-
R
L
2
3
4
5
XDZ 6 7
Plug
Plug (1-480705-0)
P-
113
Pit Inspection Box
115a
D
2
3*0.75+3*0.75mm (L=3m)
PC-1
Pin
Wire No. in Drawing Cable
1
115e
1
2
115d
2
PC1
3
PE
3
1-480704-0
4 5
115d 115b
1
6
PE
3
1 115e
No.
2 115d 3
2
1
5
6
4
PC-1
PC-1
AMP 1-480704-0
2
3
PE
2
PE
3
2
3*0.75mm
4 115d
1
5 115b
2
6
3
PE
115d
1
PB1 115d
2
3*0.75mm
115b
PB2
PE
SKT2
P+ P- R L Pit Intercom
Plug (1-480705-0)
Pit Inspection Box Emergency Stop
XK Pit Socket
EKM Pit light
C
Pit Inspection Box
Buffer Cable PB3 PB4 2 3*0.75+3*0.75mm (L=3m)
Plug
Pin 1
109
1
2
112
2
PC2
3
PE
3
1-480704-0
4
112
1
5
113
2
6
PE
3
Cable No.
Wire No. in Drawing
1
109
1
109
1
2
113
2
113
2
3
115a
3
115a
3
4
115b
4
115b
4
5
P+
5
P+
5
6
P-
6
P-
6
7
R
7
R
7
8
L
8
L
8
PE
10
1 109
1
2 112 6
5
4
PC-2
3 PC-2
AMP 1-480704-0 Note: Cancel PB3 and PB4 cable when speed≤1.0m/s.
PE
2
PE
3
2
3*0.75mm
4 112
1
5 113
2
6
3
PE
112
1
10
3
2
1
6
5
4
9
8
7
12
11
10
PB3
C
112 2
113
PB4
PE
HD
Pin
1 2 3 4 5 6 7 8 9 10 11 12
Plug
B
HD 1-480708-0
9
9
A
2
Pit Inspection Box
1-480708-0
Wire No. in Drawing
Pin
Plug(1-480709-0)
Plug(194014-1)
Control Box Interface Board
HD
3
AMP 1-480708-0
8*0.75+1*2.0mm Round Cable B
109
No.
3*0.75mm
Hoistway Round Cable CB3
Plug
PB3=5M PB4=5M
Wire No. in Drawing Cable
Note: Make terminal 109 and 113 on CN1short circuit when speed
OL Fire
ND1
X CZ MZ XF JX
+24V
>
J1
JE1
3 2
+24V
JN1
ND17
2
1
D
1
BL2000-CEB SN2
SN24 4
1
2
6
7
8
9 10 11 12 14 15 16 17 J5
BL2000-HXJ-V9 Car LCD Display Conversion Board 3
3
2nd floor car call
ND2
+24V
3 JN2
2
J2
4
BY0
4
Overload BY1
3
16th floor car call
ND16
+24V
JN16
SN25 4
2
>
1
EB
AMP 1-480707-0
4 5 6 7 8 9
C-
9
24V GND C+ C-
C+
8
24V
7
EB 1 2 3
JE1
3 2
C
+24V
1
When there is vice-COP or disabled COP, add the plug-in, wire length is 6m.
BL2000-CEB
KM 4 VH4
3
Door Open Button
CANPE
+24V
Choose CH4 Plug-in according to different display board.
PE 105
J1
ND25
GND
3 6 Plug (1-480707-0)
2 5
1
SN16
J3
C
1
+24V
ND24
J2
BL2000-ZLB J2
J1 24V GND C+ C-
4
JE8 2
>
1
C-
J1
2
GND
24V
1
C+
J3
4
SDC Car emergency stop
SN32
J2 4
2
3
1
JE8 2 J2
100
+24V
ND32 1
GM 4
Equip 350218-1 pin in AMP plug.
B
2
6
5
4
9
8
7
12
11
10
EA
AMP 1-480709-0
Pin 1 2 3 4 5 6 7 8 9 10 11 12
3
Door Close Button
EA
1
Plug (1-480709-0)
3
+24V
Cable No.
J3
2 1
L33 EM FA
SJM1 SFA
P+ PR L YJ+
B
Light Fan
+
-
R
Call button
YC 4
呼 叫
L
3
Door Open Prolong Button +24V
Hands-free intercom (Wiring as actual intercom)
JL
2
J6
J4
3
ZS
Bypass button
ZY
Special button Fireman button
XFY
2
4
1
E. light
YJJL+ JL1
1
Alarm 1
JL+ JL1
Alarm button plug
J5 SJ
P+ PR L
By attendant button
4
A Add it when there is vice-COP or disabled COP, wire length is 6m.
Note: When there is vice-COP or disabled COP, make branch plugs for Indicator communication wire in main COP and extend additional wires. Wire length is 6m. Draw branch line from alarm button and make relative plugs, line length is 6M.
Design Check Approve
QianJianqiang
Date
2016.12.14
COP wiring
Draw No. Sheets Sheet Remark
TRF110 18 17
Draw branch line from connection line of intercom, press the wiring terminal and cover number tube, line length is 6M. 1
2
3
4
5
6
7
8
A
1
2
3
4
5
6
8
7
J1
SN17
To car top communication board J8
4 4
D
J9
3
1st floor car call
ND1
+24V
>
SN1
>
J1
JE1
3 D
+24V
2
JN1
ND17
2
1
1
BL2000-CEB
Car Indicator SN2
SN24 4
2nd floor car call
4
3 ND2
+24V
3 JN2
JE8 2
2
>
1
+24V
ND24
J2
1
BL2000-ZLB JP1 JP3
超载
SN16
JP2
4
JP4
16th floor car call
J1 24V GND C+ C-
C
3 ND16
+24V
JN16
SN25 4
2
>
1
J1
JE1
C
3 +24V
2
ND25 1
BL2000-CEB
KM
Indicator communication wire should be connected to main COP
4 3
Door Open Button
+24V
SN32
J2
4
2
3
1
JE8 2 J2
+24V
ND32 1
GM 4 3
Door Close Button +24V
J3
2 1
B
B
YC 4
Call button
+ R L
3
Door Open Prolong Button
Call
-
+24V
Hands-free intercom (Wiring as actual intercom)
JL
J4
2 1
Alarm
Add when there is vice-COP or disabled COP, the wire should be connected to main COP.
A
Design Check Approve Date
1
2
3
4
5
6
Draw No. Vice COP & Sheets Sheet Disabled COP circuit Remark 2016.12.14
TRF110 18 18
QianJianqiang
7
8
A