380V Electrical Drawing PDF [PDF]

  • 0 0 0
  • Gefällt Ihnen dieses papier und der download? Sie können Ihre eigene PDF-Datei in wenigen Minuten kostenlos online veröffentlichen! Anmelden
Datei wird geladen, bitte warten...
Zitiervorschau

1

2

3

4

5

6

8

7

D

D

Main power switch in M.R.

EPS power unit

K LA

LA1

LB

LB1

LC

LC1

L1

R

L2

S

L3

EPS13

N N



PE PE

C

PT

Q

T Control cable number or terminal number

Power of user 380V

Main power switch(by others)

L1

U1

L2

V1

L3

W1

KDY Running contactor 1 2

U3

R

U

S

V

3

4

V3

T

W

5

6

W3

BL6-U 12V

+12V

0V

0V

1/5

141 116

IA

A

2/6

PG-V6X/JENDAT IB

B

G4

3/7

GND

4/8

YJ

E-KIB-A

PG

C

Controller interface board

GE

Brake resistor

B1

RZD

B2 B

B

A

A

QianJianqiang Design JiangYongliang Check Mian circuit Approve Zhengyanfeng

Date

1

2

3

4

5

6

2016.12.5

7

Draw No. TRF110 16 Sheets 1 Sheet Asynchronous motor Remark

8

1

2

3

4

5

6

8

7

D

D

Main power switch(by others)

EPS power unit LA1

LB

LB1 LC1

L1

R

L2

S

L3

EPS13

N N



PE PE

C

Q L1

U1

L2

V1

Running contactor

KDY

R

U

1

S

V

3

2

U3

4

V3

6

W3

KDY KDY

W1

L3

T Control cable number or terminal number

Power unit 380V

K LA

LC

PT

Main power switch in M.R.

5

W

T

32

22

31

21

BL6-U 1/5

141

2/6

116

3/7

GND

4/8

YJ

G4

E-KIB-A

Controller interface board

KFX

+5V

+5V

9

0V

7

0V

A+

5

A+

A-

6

A-

B+

8

B+

B-

1

B-

C+

11

C+

C-

10

C-

12

D+

SPG-V6/JENDAT D+

Mian motor

D-

13

D-

R+

3

R+

R-

4

C

PG

R-

GND-E

HEIDEHAIN 1387

B1

B

B

RZD

Brake resistor

B2

A

A

QianJianqiang Design JiangYongliang Check Approve Zhengyanfeng

Date

1

2

3

4

5

6

Main circuit

2016.5.14

7

Draw No. TRF110 16 Sheets 2 Sheet Synchronous motor Remark

8

1

2

3

4

5

6

8

7

D

D

Control power transformer TC1

100 AC110V

F2(1P2A) 101

Control power breaker

F1(3P6A) 0V

U1

R1

+

103

DC110V 380V

S1

102

-

400V

V1

415V

C

C

200 AC220V

W1

F3(1P4A)

T1

Phase relay KXX

L1

L2

14

11

201 L N AVR Switch power V+ V-

L3 12

GND1 24V

141 116

B

B

A

A

Design Check Approve Date

1

2

3

4

5

6

QianJianqiang

Control power & Brake circuit 2016.5.14

7

Draw No. Sheets Sheet Remark

TRF110 16 3

8

1

2

3

4

5

6

8

7

D

D

Running contator

F4(1P4A) M1-P06

M2-P12

103/400/T1/200

44

KDY 43

Brake contactor

KLZ 1

M5-P03

M5-P04

BK0

M300

Brake voltage

Brake contactor

2 M2-P14

Brake

RA-P04

RA-P05

LZ1

BK1

M5-P05

M2-P15

KLZ 4

3

BK2

Short-circuited

M2-P13

M1-P05 102/401/N/201

301

Power supply terminal

DC110V 103

102

AC220V

T1

N

AC220V

200

201

DC220V

400

401

DC24/48V 400

401

+

C

EPB J5 J6 C

Brake release device

AC220V

N/201

N

TC2

Note 1

+

L

T1/200

400 DC220V/DC48V

401

-

B

B

Note 1:When brake voltage is DC220V, TC2 adopts rectifier. When equipped with Yaskawa traction machine, TC2 adopts DC48v switch power. When equipped with Emergency cabinet, input power connect 200 and 201.

A

A

QianJianqiang Design Check Brake circuit Approve

Date

1

2

3

4

5

6

2016.5.14

7

Draw No. Sheets Sheet Remark

TRF110 16 4

8

1

2

3

Emergency stop in car D

Emergency stop on car top

SDC M1-P10

4

SDH

105

TA-P01

SOS-P01

SPC

100

100

Safety gear switch

Levelling pin

CIB-P06 RTES-P01

EB-P07 CIB-P05

6

SNQ

RTES-P03

106

HB-P07

TA-P02

111

HD-P01

SXJ

108

PC2-P01

PC2-P04 SHC1 PC2-P02

109

HB-P08

CIB-P07

SHC2

HA-P07

Top final limit SSJ

113

Emergency power driven

GJ M3-P05

CIB-P08 TA-P03

110

S5

M3-P06

110A

Emergency stop in switch box of pit

Emergency stop in maintenance box of pit SKT2

SKT1

HD-P03

Emergency Stop in High Platform

Rope breakage switch PC1-P02

115a

PC2-P05 HD-P02

112

DJ

Safety circuit

D

CW buffer switch

Car buffer switch

Bottom final limit

SOS-P03

Inspection on car top

M3-P07

8

7

Emergency stop of rear door

SDT

EB-P09

5

PC1-P04

SKS

PC1-P05 HD-P04

G2-P01

SDR

115b

115d

115e PC1-P01

Up overspeed switch

Handwheel switch

G2-P03 G2-P04

G2-P07

SPC

115c

G2-P09

SCS

115

G2-P06

Speed governor down overspeed switch RB-P01 RB-P03 SXS

114

114a

HA-P08

C

C

Emergency stop in control cabinet

M5-P07/M6-P09/G4-P02

Phase relay

SJT M3-P08

M1-P04

KXX 14

G1-P01

11

141

J7-5(X29+)

116

M1-P03

Door interlock circuit

G1-P02

J7-2(X31+)

G1-P03

J8-3 (X32+) Front landing door on 1st floor HE1-P03

SMn

SM1

Front landing door on N floor

HE1-P01

Rear car door switch

Front car door switch

TA-P05

117

B

SMJ GS-P01

GS-P03 RGS-P03

SMJ

TA-P04

117A

HE2-P01

RGS-P01

SMn

Rear landing door on 1st floor SM1 HE2-P03

118B Rear landing door on N floor

TA-P06/M6-P10

G2-P12

G2-P13

118

G1-P04

J7-3(X30+)

118A

Short-circuited

Main control board M5-P08/M6-P11

B

M2-P06

MU-V61 VL2

J8-2(X32-) J7-4(X29-) M1-P09

Note:1. When there is no rear car door, short connect 117A and 118 of BY terminal of interface board E-CIB-A on car top.

G1-P05

J7-1(X30-)

101

2. When there is no rear landing door, short connect 118 and 118B of D1 terminal of interface board E-KIB-A on control cabinet.

A

A

QianJianqiang Design Check Safety door lock circuit Approve

Date

1

2

3

4

5

6

2016.5.14

7

Draw No. Sheets Sheet Remark

TRF110 16 5

8

1

2

3

4

5

6

8

7

D

D

HA-P05

HB-P05

HA-P03

HB-P03

Top terminal 2

Bottom terminal 2

SDZ2

XDZ2

HA-P02

HB-P02

Up door zone

Down door zone

SMQ

KBK1

XMQ

DZ-P06

DZ-P03

TA-P9

TA-P10

RA-P02

KBK2

RA-P03

+24V

44

44

32

KDY

KLZ 43

31

M2-P09

Red KFX 43

M2-P10

G5-P02

3#

EPS 4#

G5-P03

G4-P04

Black M2-P08

XF

G5-P01

XF2

G5-P10

SDF

Electric lock

XDZ1

Fireman switch 2

Bottom terminal1

GND

Fireman switch 1

SDZ1

G5-P05

GND Input signals when EPS drives microprocessor

Top terminal 1

XXV

G4-P03

GND

KCZ

Bottom limit

SXV

G5-P04

GND

GND

Optional for M.R. overloading

Shown in Inspection circuit

Top limit

M2-P11

RA-P01

GND

Temperature control signal

M1-P02

DZ-P04

KWK

M1-P01

Connect when lift speed ≥2.0m/s

GND

FAR

HB-P06

GND

Fan:DC24V

HA-P06

Brake detecting switch 2

+24V

Brake detecting switch 1

GND2

G5-P09

C

C GND

+24V

JX(X0)

MS(X1)

MX(X2)

121(X5)

122(X6)

124(X8)

123(X7)

119(X3)

120(X4)

Optional Y1

COM1

COM3

Y7

Y9

XMQ(X10)

SMQ(X9)

KBK1(X15)

E-KIB-A

Y6

COM4

Y8

Y10

COM5

24V

Y11

COM

CAN+ 2H

M2-P04

M2-P01 Economic resistor contactor(Optional)

M2-P05 13

KFX 14 A1

101 B

M2-P07 Connect when there is Fire fighting function

KJR

KDY A2

Running contactor

LD1

Brake contactor

KLZ LD2

M7-P12 M7-P11

A1

A2

CAN-

X17

M7-P09

5

3

6

A2

1

C-

M7-P10

M7-P07

2

116

4

117

CZ(X25)

YJ(X18)

G1 5

XF2(X24)

X20

Optional

CN1

3

118A 101

XF(X12)

118

M7-P08 24V+ GND C+

A1

WK(X21)

M7 1

24V+ GND C+

2L

X11

M2-P03

Star shorted contactor

M2-P02

KBK2(X19) X16

1

2

J6

6

C5

5

2

A1

KFX

24V

GND

C+

3

J7

1

4

2

J8

3

J1

MU-V61 VL2

C-

TC-P01 TC-P02 TC-P03 TC-P04

A2

Spare

Spare

24V

GND

C+

8

C-

HC-P01 HC-P02HC-P03 HC-P04

Car top PCB communication

J6

7

4

B

Hop communication 118A

M2-P06

100

M1-P10

CB+

CB-

GND1

For Twin control/Group control

S1

4 3 2 1

PE CANPE

A

QianJianqiang Design Check Control corcuit Approve

GND

Date

1

2

3

4

5

6

2016.5.14

7

TRF110 16 6

Draw No. Sheets Sheet Remark

8

A

1

2

3

4

5

6

7

8

D

D

Emergency power driven

Inspection on car top

GJ

DJ CIB-P02 TA-P11

M3-P01

130

CIB-P01

M3-P02

130A

S2

JX

COM in M.R. FMG

JX (X0)

S6 FMS

M3-P03

MS

MS (X1)

E-KIB-A

Jog up in M.R. FMX

MX

M3-P04

COM on car top DMG

Jog up on car top

MX (X2)

Jog down in M.R.

DMS

CIB-P03 TA-P07 C

Jog down on car top

DMS

S3

C

DMS

CIB-P04 TA-P08 DMX

S4

B

B

A

A

Design QianJianqiang Check Approve Date

1

2

3

4

5

6

2016.5.14

Draw No. Sheets Inspection circuit Sheet Remark

7

TRF110 16 7

8

1

2

3

4

5

When using Blue Light SJT-150,leave them

6

8

7

For double entrance D

D

LWD-P04 24V

GND

RDR-P08

GND

C-

C+

RDM-P09

GND

DR-P08

GND

Light load

KBZ

KMZ

KCZ

Half load

Full load

Overload

LWD-P02 LWD-P03

TC

X8

LWD-P07

X9

2KAB1

KMV2

Door close limit 2

1KAB1

Door open limit 2

RDM-P08

RDM-P07

DR-P09

KAB2

GMV2

KMV2

KAB1

X6

X5

GMV1

Light curtain 1

RDR-P09

X11

X10

Safety edge 1

GMV2

Light curtain 2

LWD-P08

GND

1KAB2

Safety edge 2

TC-P04

TC-P03

TC-P02

TC-P01

2KAB2

KQZ

DM-P09

GND

X4

Door close limit 1

DM-P08 GMV1

X2

KMV1 Door open limit 1

DM-P07 KMV1

X1

X0

E-CIB-A

For double entrance

C

Y0

Y1

Y3

Y4

JR1

JR0

Arrival chime

CM1

KM

GM

CM2

KM2

Door close 2

GM2

GND

+24V

VB-P01

black

L31

+24V

L33

VB-P02

J1

yellow

VB-P02

Door open 2

VB-P01

Door close 1

CN1

J3

J4

buzzing

BEL

Door open 1

CN2

BY-P05

BY-P04

EA-P02

TB-P08

VB-P04

VB-P03

RDM-P12

RDM-P11

RDM-P10

DM-P12

DM-P10

DM-P11

CN3

red

C

JR2

BL2000-JDB

GND

Optional

Lighting fan control

B

B

A

A

QianJianqiang Design Check Approve

Date

1

2

3

4

5

6

Car top PCB control circuit

2016.5.14

7

Draw No. Sheets Sheet Remark

TRF110 16 8

8

1

2

3

4

5

6

Applicable for MRL lift

L31

201 200

FXS

Main door

VVVF Door Operator

D

U

U5

V

V5

W

W5

L

200

N

201

N1 Car Top Light Switch

G6-P01 L31

Door Motor

SDM

TB-P08

[6]

KMV1

B3(PC2) [5]

GMV1 GND

C2、C3(PAC) [4]

SGK

DM-P01 DM-P02

Control cabinet light

JR1

EA-P02

SJM1

EA-P03

Car light switch

DM-P07 DM-P08

GM

2(CD)

[3]

1(OD)

[2]

KM

8(CM)

[1]

CM1

V

SFA

13

DM-P11

TB-P09 Fan AC220V

FAR

14

For floor number above six(choose either it or DC24V fan) Hoistway Light Switch (Pit)

SZMf 2

N2

SZMk L32A

1

2 L35

1

ECM1

Door motor

N

201

Hoistway light

DM-P01 DM-P02

+24V PGA Encoder

PGB COM

KMV1

TB3

GMV1

TB1

GND

TA1/TA3

KM

DI5

GM

DI6

CM1

COM

DM-P07

U

U6

V

V6

W

W6

L

200

N

201

L32B

3

2

3

ECMn

EKM

Pit Light

RDM-P01

Pit Light Switch

RDM-P02

G6-P04

Pit light Socket

EM

XK EM3 VA-P05 G6-P05

VA-P04

Hoistway light for car top(optional) B

Q1 KMV2

[6]

B2(PC1) B3(PC2) [5] C2、C3(PAC)

DM-P08

2

Door motor

SKK

Vice door

200

C

DM-P10 L32

VVVF Door Operator

ST

VVVF Door Operator

L

FANZM/FS-P01

ZM/FS-P02

KDY

DM-P12

TB-P09

EM2

Car fan

FA

EA-P04

EM1 ZM/FS-P04

Car light

W7

W

B

car light

EM

L33

DM-P09

Hoistway Light Switch (M.R.)

V7

XG

ZM/FS-P05

E-CIB-A

U7

U

EGM

Control cabinet light switch Control cabinet socket

Car fan switch

C

D

VA-P02

XD

Car Top Light Socket

G6-P02 N1

Optional for MRL

B2(PC1)

Speed governor reset

TB-P09

EDM

Car Top Light

VA-P01

TB-P08

XS2

XS1

Speed governor action

8

7

GMV2 GND

[4]

L3

L31

RDM-P07 RDM-P08

Lighting Breaker (1P4A) Including car lighting, safety lighting.

N

RDM-P09

DM-P09

N1

Q2

DM-P11 DM-P12 DM-P10

2(CD)

[3]

GM2

1(OD)

[2]

KM2

8(CM)

[1]

CM2

L32

RDM-P12 RDM-P11

Hoistway lighting breaker(1P10A)

N2

RDM-P10

Note: The terminal no. outside ( ) are for Shenling operator, the terminal no. in ( ) are for Eshine door operator. The number in [ ] are cable no. for Shenling door operator.

A

A

QianJianqiang Design Check Approve

Date

1

2

3

4

5

6

Door operator Lighting circuit

2016.5.14

7

Draw No. TRF110 16 Sheets Sheet 9 Remark

8

1

2

3

4

5

6

Electric lock

+24V

HC-P01

Fireman switch

(locked when switch on)

GND

HC-P02

8

7

(fireman function when switch on)

C+

HC-P03 HC-P04

CD

4

3

2

1

2

3

4

1

DZZ 2

Arrival gong output(ne gtive edge triggering)

3

4

-24V

+24V

1

BY/BY1

BY1

1

4

3

DZD 2

3

4 Top arrival light

Bottom arrival light

+24V

1

SM

C

2

BY0

4

3

2

J2 2 +24V

3

4

1

2

3

+24V

4

1

2

J3

HAH

J1

1

4

3

2

HAH 3

+24V

4

1

J2

BY/BY1 2

3

4

1

+24V

2

J3 3

4

J1

1

4

3

2 1

2 +24V

3

4

1

2 +24V

3

4

J3

J2

HAH

HAH

J1

1

4

3

2

J1

1

1

D

SM

C

BEL

N floor down call

Vice landing door lock (Optional for two-circuit)

N-1 floor up call

2nd floor up call

Lift A 8

BL6-U

J6

7 2

CB+

CB+

CB+

CB-

CB-

CB-

7

GND1

GND1

GND1

2

Arrival light output

J6

5

1

2

Full Load

6

5

Inspection

3

4

1 4

J1 J2

4

3

3

Up Call +24V

2

2

1

1

4

4

B

2

6

7

8

9 10 11 12 14 15 16 17 J5

BL2000-HXJ-V9

4

J2

J1

J1 Call box LCD display transformer board

HAH J3

3

3

Down Call

2

+24V

J3

2

1

1

3

J2

HAH A

2

D C B A S X CZ MZ XF JX

E-KIB-A

HC-P04 M7-P06

HC-P03 M7-P05

When two lifts are of duplex control and use two seperate simplex HOP, please do the wiring as the above. When use one duplex HOP, please only connect the duplex wires.

HC-P02 M7-P03

HC-P01 M7-P01

HC-P04 M7-P06

V+ V- E

J3

2

Vice landing door lock (Optional for two-circuit)

Indicator

BL6-U

1

1

Arrival gong output

J6 6

HC-P03 M7-P05

HC-P02 M7-P03

E-KIB-A

HC-P01 M7-P01

B

2

1st floor up call

Lift B

8

J6 1

2nd floor down call

1

2

3

4

5

6

Design Check Approve

QianJianqiang

Date

2016.5.14

Draw No. TRF110 Landing call circuit 16 Sheets 10 Sheet LCD display Remark transformer board

7

8

A

1

2

3

4

5

6

J1

BL6 GND

24V

4

GND

C+

J9

>

3

1st floor car call

C-

C+

>

24V

SN17 4

SN1

CN1

D

8

7

ND1

+24V

J1

JE1

3 2

D

+24V

JN1

ND17

2

1

1

C-

M7-P03

M7-P05 M7-P06

TC-P01

TC-P02

TC-P03

TC-P02

TC-P04

TC-P03

SN2

SN24 4

2nd floor car call

TC-P04

CN3-P01 CN3-P02 CN3-P03 CN3-P04

4

3 ND2

E-CIB-A

TC-P01

E-KIB-A

BL2000-CEB M7-P01

+24V

3 JN2

2

JE2 2

>

1

+24V

ND24

J2

1

BL2000-ZLB SN16 4

GND

24V

C+

16th floor car call

C-

3 ND16

J1

C

BL2000-JDB Car Top PCB

+24V

JN16

SN25 4

2

>

1

J7

J1

ND25 C-

EB-P02

EB-P03

3

Door open button

CN3-P01 CN3-P02 CN3-P03 CN3-P04 EB-P01

4

C-

EB-P04

+24V

Over load

E-CIB-A

C+

GND

D C B A S

SN32

J2 4

2

3

1

Fire V+ V- E

BL2000-CEB

KM

Display board 24V

+24V

1 C+

GND

C

3 2

J1 24V

JE1

JE2 2 J2

X CZ MZ XF JX

+24V

ND32 1

GM 4 3

Door close button

+24V

J3

2 1

B 1

2

6

7

8

B

9 10 11 12 14 15 16 17 J5

BL2000-HXJ-V9

J1

J3

1

2

J2

3

4

1

YC 4

Door open prolong button Car LCD display transformer board

3 +24V

2 J4

J6

3

ZS

Bypass button

ZY

Special use button Fireman button

XFY

2

4

1

1

24V 1

GND 2

C+ 3

J5

C-

XFY 4

4

By attendant button

CN1 A

Car indicator

1

2

3

4

5

6

Design Check Approve

QianJianqiang

Date

2016.5.14

Car call loop

7

Draw No. Sheets Sheet Remark

TRF110 16 11

8

A

1

2

3

4

5

6

SJT-ZPC-V2A(VM1)

E-KIB-A JP1-1

M6-P01

+24V

24V

12

GND

11

11

K11

12

K14 11

21

K12

GND

DZ-P04

K10

JP1-2

M6-P02 D

8

7

D5

A2

K12

D

D1

61

64

GND

A1

12

K11 22

21

R1

K10 22

C1

Advanced door opening/releveling door zone switch

ZPS

K12

ZPS

DZ-P08

M6-P03

32

JP1-3

31

A1

K10 TB-P01

Up releveling door zone input

Advanced door opening/releveling relay output

COM0

M6-P07

44

M6-P02 Y0

ZPX

DZ-P09

M6-P04

D2

54

JP1-4

51

A1

K11 TB-P02

Down releveling door zone input

31

JP1-5

M6-P08

Y0

32

A2

K11 D3

K12 21

A1

22

Y0

A2

K14 D2

K14

Advanced door opening/releveling signal detection X22

A2

K10

K12

ZPX GND

41

M6-P05

JP1-6

42

K10

41

31

K11 32

41

42

X22

JP1-7

C

Releveling door zone input

M6-P06 X23

C

JP1-8

X23

JP1-9 K14 M6-P09

JP1-10

Door close lock M6-P10

JP1-14

Door close lock M6-P11

JP1-11

116

Optional function: Advanced door opening and Releveling

44

K10 43

61

12

54

K11 64

51

K14 54

51

54

Add for double entrances 117A

118B

B

B

JP1-12

K12 11

K10

K11 51

61

64

JP1-13

A

A

Design Check Approve Date

1

2

3

4

5

6

Draw No. JiangYongliang Advanced Door opening Sheets /Releveling ZhengYanfeng Sheet UCMP Remark 2016.5.14 QianJianqiang

TRF110 16 12

Optional function

7

8

1

2

3

4

5

6

JT-2000C

JT-04A1

IC card controller

IC card controller

J22 24+ 24-

8

7

J1

24+ 24- 1 2

OUT1+ 0UT1-

D

J8

3 -

4

1 2

3 -

+

4 +

D

EPSS-EPB36/110/220 24T GND1

24T GND1 DC12V output

Charging power input J2 J1

J3

J4

J5

J6

P6

P7

SN1

SN16 4 3

1st floor car call

ND1

-

+

4

JN16

JN1 2

100

101

BK0

BK2

M5-P02

M5-P03

M5-P05

16th floor car call

+24V

2

ND16 1

M5-P01

3

1

SN2 4

E-KIB-A

SN17 3

2nd floor car call

Power line DC12V

ND2 2

3

>

1

C

4

J1

J9

JN2

>

JE1 2

+24V

17th floor car call ND17

C

1

Video Cable

BL2000-ZLB

SN3

4 Controller LCD displayer

Shaft Traction Monitor

3

3rd floor car call

ND3

+24V

Note:

JN3

When JT-2000C is applied ,the connection of wire 3 &4 between extension card and IC card controller should be reverse. When JT-04A1 is applied, instruction on CZB board should be

2 1

connected to OUT1,instruction on extension board should be connected to OUT2.

Applicable for MRL Lift with EMK electric break release and machine monitor function SN8 4 3

8th floor car call

ND8

+24V

JN8 2 1

B

B

JL1

+

-

R

L

+

-

R

Car Inside

L

-

EB1EB2 +

R L

EA-P08

EA-P07

EA-P06

EA-P05

TA-P15 HD-P08

TA-P14 HD-P07

TA-P13 HD-P06

P+

TA-P12 HD-P05

EPS2-P06

G3-P04

L

EPS2-P05

G3-P03

TA-P15

R

EPS2-P04

G3-P02

-

Call

+

L

TA-P14

R

Guard room

Pit

EYJ

Alarm

EPS1-P01 EPS1-P02

EA-P12 EPS2-P01

EA-P09 EA-P10

YJ+ YJ-

-

G3-P01

P-

+

TA-P13

P+

EPS1-P05

+ EPS1-P09

EPS1-P07

EPS1-P08

EPS1-P06 EA-P11 EPS2-P02

JL+ JL-

L31 N1

-

+

EPS1-P04

-

+

Car top

M.R.

Intercom

TA-P12

E. Light

EPS2-P03

Emergency Power Box Alarm AC220V

PR

A

A

L

Single elevator intercom system

1

2

3

4

5

6

Design Check Approve

QianJianqiang

Date

2016.5.14

Draw No. TRF110 Intercom, 16 Sheets Optional Function Sheet 13 Remark

7

8

2

3

J1-4

J6-8 J6-7

J1-8

GND1

Lift A

J1-7

GND1

CB-

J6-2

J1-6

1L

CB+

J6-7

1H

BL6-U

J6-2

BL6-U 1H

J6-8

1H

1L

J6-7

1L

GND1

J6-2

GND1

Lift B

Lift H

CB+

+5V

D

CB-

N

BL6-U J6-8

8

7

GND1

J1-3

CB+

0V

CB-

L AC220V

N

6

BL2000-QKB

AVR2

(4A)

L3

5

GND1

F5

D

4

Group Control Board

1

C

C

Group control system circuit

AVR

200

L

+5V

4

AC220V

201

B

N

0V

BL6-U 2

Wired monitor and control system circuit:

GND1

BL20006 KIC/KID 3

J6 6

C+

9

5

C-

10

J1

B

SJT-QIC/QID YH

H

7

YL

L

J1 8

YG

G

Monitoring center

area communication cable RVVP(2*2)P*0.75 (One for each control cabinet)

Control cabinet Power supply AC220C

Note:Use one data collector for each monitoring system, it can monitor several elevators.

A

A

1

2

3

4

5

6

Design Check Approve

QianJianqiang

Date

2016.5.14

Draw No. TRF110 Optional Function 16 Sheets Sheet 14 Group control circuit Remark

7

8

1

2

3

4

5

6

8

7

Monitor Room Emergency Power Box E light

+

L

+

-

R

L

-

EB1EB2 +

NKT12(1-1)16N--59N Main

R L

AC AC

AD2

Call

AD1

+

-

D

EA-P08

EA-P07

EA-P05

EA-P06

From main intercom to pit of lift #1 RVVP5* 0.75

TA-P15 HD-P08

TA-P14 HD-P07

TA-P13 HD-P06

TA-P12 HD-P05

EPS2-P06

G3-P04

EPS2-P05

G3-P03

TA-P15

EPS2-P04

G3-P02

TA-P14

EPS2-P03

G3-P01

AL

+

A- AR

+ TA-P12

HD-P05 XDZ-P+

TA-P13

HD-P06 XDZ-P-

TA-P14

HD-P07 XDZ-R

TA-P15

HD-P08 XDZ-L

AL

AD1

AC220V

AD2

Adapter R1 L1

Car Top

Pit

A- AR

AL

AD1

AD2

L

+

Car

-

R

L

-

EB1EB2 +

C

R L

From lift #1 to pit of lift #2 RVVP 5*0.75

EA-P08

EA-P07

EA-P06

EA-P05

TA-P15 HD-P08

TA-P14 HD-P07

TA-P13 HD-P06

TA-P12 HD-P05

EPS2-P06

EPS2-P05

G3-P04 TA-P15

R

EPS2-P04

G3-P03 TA-P14

EPS2-P03

G3-P02

-

Call

+

L

G3-P01

P-

R

TA-P13

P+

-

TA-P12

+ EPS1-P05

EPS1-P04

-

P+ P-

EYJ

EA-P12 EPS2-P01

Alarm

+ EPS1-P09

EA-P09 EA-P10

EPS1-P08

EPS1-P07

EPS1-P06

R

E. Power

Intercom

-

EA-P11 EPS2-P02 JL1

TA-P13

P-

MR.

E light

+

YJ+ YJ-

L31 N1

-

P-

JL+ JL-

EPS1-P01 EPS1-P02

+

L

L

-

+

R

R

Alarm AC220V

-

TA-P12

P+

Emergency Power Box C

Car

A- AR

EYJ

Alarm

JL1

-

P+ EA-P12 EPS2-P01

L31 N1

EPS1-P01 EPS1-P02

+ EPS1-P09

YJ+ YJ-

EA-P09 EA-P10

EPS1-P07

EPS1-P08

EPS1-P06 JL+ JL-

EA-P11 EPS2-P02

D

Pit

Intercom

-

+

EPS1-P05

-

EPS1-P04

Alarm

+

AC220V

Car Top

MR.

A- AR

+ TA-P12

HD-P05 XDZ-P+

TA-P13

HD-P06 XDZ-P-

TA-P14

HD-P07 XDZ-R

TA-P15

HD-P08 XDZ-L

AL

AD1

AD2

R

Adapter R1

L

L1

A- AR

AL

AD1

AD2

B

B

From lift #2 to pit of lift #N RVVP5* 0.75

Emergency Power Box

R

+

L

-

R

L

+

Car

-

R

L

-

EB1EB2 +

R L

Call

P-

3

4

AD2

R L

EA-P08

EA-P07

EA-P06

1. Cable is RVVP 5*0.75

Adapter

TA-P12

HD-P05 XDZ-P+

TA-P13

HD-P06 XDZ-P-

TA-P14

HD-P07 XDZ-R

TA-P15

HD-P08 XDZ-L

5

2. Single bus should not bifurcation or star wiring 3. Intercom should be connected to its own adapter

A- AR

R

2

AD1

Intercom bus cable by others and layout should be reasonable

L

1

AL

+ -

EA-P05

TA-P15 HD-P08

TA-P14 HD-P07

TA-P13 HD-P06

TA-P12 HD-P05

EPS2-P06

EPS2-P05

EPS2-P04

EPS2-P03

G3-P04 TA-P15

G3-P03 TA-P14

TA-P12

P+ EYJ

Alarm

-

G3-P02

P-

EA-P09 EA-P10

EA-P11 EPS2-P02 JL1

EA-P12 EPS2-P01

A

Pit

A- AR

YJ+ YJ-

JL+ JL-

EPS1-P01 EPS1-P02

+

G3-P01

P+

L31 N1

-

TA-P13

+ EPS1-P09

EPS1-P08

EPS1-P07

EPS1-P06

-

+

Car Top

Intercom

EPS1-P05

-

+

AC220V

MR.

E light

EPS1-P04

Alarm

6

AL

AD1

AD2

Design Check Approve

QianJianqiang

Date

2016.5.14

Optional Fuction NKT12 Intercom (bus connection)

7

TRF110 16

Draw No. Sheets Sheet Remark

15

8

A

1

2

3

4

5

6

8

7

Monitor Room Emergency Power Box E light

+

R

+

L

R

-

L

+

Car

R

-

L

-

EB1EB2 +

R L

Call

TA-P15 HD-P08

EA-P08

EA-P07

EA-P06

EA-P05

TA-P14 HD-P07

TA-P13 HD-P06

TA-P12 HD-P05

EPS2-P06

G3-P04

EPS2-P05

G3-P03

TA-P15

EPS2-P04

G3-P02

TA-P14

EPS2-P03

G3-P01

TA-P13

HD-P06 XDZ-P-

TA-P14

HD-P07 XDZ-R

TA-P15

HD-P08 XDZ-L

R1

Pit

+

L

Car

-

R

L

C

-

EB1EB2 +

R L

EA-P08

EA-P07

EA-P06

EA-P05

TA-P15 HD-P08

TA-P14 HD-P07

P+

TA-P13 HD-P06

TA-P12 HD-P05

EPS2-P06

EPS2-P05

G3-P04 TA-P15

R

EPS2-P04

G3-P03 TA-P14

EPS2-P03

G3-P02

-

Call

+

L

G3-P01

P-

R

TA-P13

P+

-

TA-P12

+ EPS1-P05

EPS1-P04

-

P-

EYJ

JL1

+ EPS1-P09

EA-P09 EA-P10

EPS1-P08

EPS1-P07 Alarm

L31 N1

EA-P12 EPS2-P01

YJ+ YJ-

EA-P11 EPS2-P02

EPS1-P06 JL+ JL-

EPS1-P01 EPS1-P02

Car Top

Intercom

-

+

L1

MR.

E light

-

+

AC AC D

P-

Emergency Power Box AC220V

-

AC220V

R

Alarm

+

-

E. Power above 32 by others

L

C

E. Power

+

NKT12(1-1)6A--64A(Main)

TA-P13

P-

-

TA-P12

P+

-

EYJ

JL1

Pit

P+

EA-P12 EPS2-P01

Alarm

L31 N1

EPS1-P01 EPS1-P02

+ EPS1-P09

YJ+ YJ-

EA-P09 EA-P10

EPS1-P07

EPS1-P08

EPS1-P06 JL+ JL-

EA-P11 EPS2-P02

D

Car Top

Intercom

-

+

EPS1-P05

-

EPS1-P04

Alarm

+

AC220V

MR.

TA-P13

HD-P06 XDZ-P-

TA-P14

HD-P07 XDZ-R

TA-P15

HD-P08 XDZ-L

R

R2

L

L2

B

B

Intercon bus cable instruction: Emergency Power Box E light

JL1

Pit

L

1. Each elevator has one separate cable connecting to monitor room

Car

R

-

L

-

EB1EB2 +

R L

TA-P15 HD-P08

R1

EA-P08

EA-P07

EA-P06

L1

EA-P05

TA-P14 HD-P07

TA-P13 HD-P06

TA-P12 HD-P05

2. Cable is RVVP3* 0.75

-

Call

+

EPS2-P06

EPS2-P05

EPS2-P04

G3-P04 TA-P15

R

-

EPS2-P03

G3-P03

L

TA-P14

R

G3-P02

P-

-

G3-P01

+

+

TA-P13

EPS1-P09

-

TA-P12

P+

P-

EYJ

A

+

P+ EA-P12 EPS2-P01

Alarm

YJ+ YJ-

EA-P09 EA-P10

EPS1-P08

EPS1-P07

EPS1-P06 JL+ JL-

EA-P11 EPS2-P02

L31 N1

EPS1-P01 EPS1-P02

Car Top

Intercom

-

+

EPS1-P05

-

EPS1-P04

Alarm

+

AC220V

MR.

TA-P13

HD-P06 XDZ-P-

TA-P14

HD-P07 XDZ-R

TA-P15

HD-P08 XDZ-L

R L

1

2

3

4

5

6

Design Check Approve

QianJianqiang

Date

2016.5.14

A

Optional Fuction NKT12 Intercom (line connection)

7

TRF110 16

Draw No. Sheets Sheet Remark

16

8

1

2

3

4

5

6

7

8

200

Top Final Switch

D

SSJ D

100

Top Limit Switch

SXV

Top Terminal Switch

SDZ1

Sub Top Terminal Switch

SDZ2

*1

*2 200

Bottom Final Switch

SXJ

Bottom Limit Switch

XXV

100 C

C

Sub Bottom Terminal Switch

XDZ2 *2

Bottom Terminal Switch

XDZ1 *1

MQ Leveling Position

Leveling Zone switch

SMQ

standard elevator

XMQ

Car

H1

(Unit:mm ) Shelter Board H2 UP B

B

XMQ

ZPX

advance door open and releveling function

ZPS

SMQ

DOWN

MQ Leveling Position

Car

H3

Shelter Board H4 UP

A

Elevators have to finish hoistway learning before high speed running. The conditions below are necessary before hoistway learning. 1.Top/bottom limit switch and top/bottom terminal switch are installed, connection is correct. 2.Up/down leveling zone switch and shelter board are installed, connection is correct. 3.Safety circuit and door interlock circuit are normal. 4.General parameters and running parameters have been set. 5.Elevator can perform inspection running.

1

2

3

DOWN

Speed Item *1 *2 H1 H2 H3 H4

4

0.5m/s

1.0m/s

1.6m/s

1000

1300

2300

180 200 280 300

180 200 280 300

180 200 280 300

5

2.0m/s

2.5m/s

2300 4000 180 200 280 300

2300 6250 180 200 280 300

6

Design Check Approve

QianJianqiang

Date

2016.5.14

Draw No. TRF110 18 Hoistway Signal Sheets 1 Sheet Installation Remark

7

8

A

1

2

1

2

3

4

5

3

1

2

118A

11

GB2

10

GB1

9

114A

8

PE

7

2 2

7

39 40

8

2

3

4

5

6

6

1

1 2

2

3

4

8

9

10

11

12

6

7

8

9

Input/Output Terminal Table

10

Main Board IndicatorName XF(X12)

CN1

WK(X21) CZ(X25)

GND GND+24V X13 X14 X20

S5

13

1

116 117A118B GB1 GB2

2

3

4

5

JX

Normal inspection signal

X1

MS

Up Running Signal

TA/7 M3/3

X2

MX

Down Running Signal

TA/8 M3/4

X3

119

Up Terminal 2 Signal

HA/2

X4

120

Bottom Terminal 2 Signal

HB/2

X5

121

Spare

HA/5

X6

122

Spare

HB/5

X7

123

Up Terminal 1 Signal

HA/3

X8

124

Bottom Terminal 1 Signal

HB/3

X9

SMQ

Up door zone

TA/9

X10

XMQ

Down door zone

TA/10

X11

X11

X12

XF1

JR1

X13

X13

Emergency contactor Signal

G5/7

JR2

X14

X14

Door lock Feedback Signal

G5/8

M7

135 136 +24V DMS(X1)

7

8

MS(X1) DMX(X2) MX(X2)

HF

9

3

1

5

6

7

+24V+24VGNDGND C+

C-

COM5

1

130B JX(X0)

2

3

4

8

9

10

11

12

Y11 COM4 Y10 LD1(COM1) LD2(Y1)

130A 130

110 110A HE1

PE

4

115C

3

115C

116

PE

HB

117

3

RB

1

3

1

120

123

GND 122

PE

109

108

GND

9 PE

10

HA

124

114

136

12

7

JR0

119 121

PE

TC

114

113

24V

9

7

HC 24V

1

S2

JR11

S3 S4

JR10

1

COM2

1

Y2

2

M4 Y3

3

Y4

4

Y5

114A

GND

GND

C+

C+

5

X15

C 11

118B

10

118

CHE2 PE

118

116

7

115A

6

108

C5

CANPE

CANPE

JR4

5

JR5

GND

JR6

5

100(IN)

4

122(X6)

3

121(X5)

2

130A

1

GND

3

4

L

3

R

HD

110 117A

108 117

1

100

P+

3 GB1 1

118

P-

L35

130 XMQ R

P-

1

3

109

BYX

ZPX ZPS

201

200

3

1 KBK1

GND

JR8

BK3 BK2 BK1

R

N1

L31

6

PE

9

N2

RA KBK2

115B

L

4 L

P+

JR7

TB

1 115A 113

S8

GB2A

SMQ DMX DMS

15

B

TD

TA D1

4 JR9

7

10

13

G3 2

P-

1

P+

M1

G6

F1

E-KIB-A_V1

N2

Light fan fuse protector 1

5

L35 PE 4

3

N1 2

L31 1

9

8

7

6

5

4

3

2

2

X17

X17

Brake Contactor Signal

M2/8

Y8

3

X18

YJ

Emergency Leveling Signal

G4/4

Y9

4

X19

KBK2 Right Brake arm feedback Signal

5

X20

X20

118A

6

X21

WK

Temperature control/seismic signal

101

7

X22

X22

Releveling condition Signal

M6/5

M2 X17

8

X23

X23

Releveling sensor Signal

M6/6

X16

9

X24

XF2

Fire Linkage Signal

G5/10

X11

10

X25

CZ

Over load signal

G5/3

GND

11

Y0

300

12

COM0

301

13

Y1

BK0

14

COM1

BK2

15

Y2

BYX 118B

1

9

8

COM2

116 BK3 BK2 BK1 BK0 101 7

6

5

4

3

2

Y3 COM2

1

S1

Commu nication earthed:Left side earthed and right side connect to power(-)

Left side

S2-S8

Spare

Bridge joint

Name

Y8

Y8

Definition Star shorted contactor

COM3 Y9

COM3

COM3 Y10

Y11

1

2

3

4

Y7

M2/5

COM3

M2/5

Y10

M7/10

COM4

M6/8 Previous Door Opening Relay M6/7 COM0 M7/12 LD2 Fire Linkage Relay M7/11 LD1 Y0

Spare output

M4/1

COM2

M4/3

Y3 Spare output

M4/1

COM2

M4/4

Y4 Spare output

COM2

M4/1 M4/5

Y5 Spare output

COM2 Y6

B

M4/2

Y2

M4/1 M2/1

Economic resistor contactor

COM3

M2/5 M2/2

Y7 Brake contactor

M2/5

COM3

A

M7/9 M7/8

Y11 Spare output

COM5

M2/3

COM3 Spare output

COM4

COM3

G5/2

M2/4

Y9 Running contactor

A

Y6

Interface board position No.

RA/3

G5/9

Electric lock signal

100(IN)

Input & output terminal comparison table Main board indicator light

C

M2/9

Running Contactor Signal

COM3

COM2

Factory setting

RA/2

Y7

Y5

Definition

KBK1 Left Brake arm feedback Signal X16

COM2

Jumper wire and bilateral switch

G5/1

X16

Y4

Name

D

M2/10

Fire Signal

1

M5

100 101 200 201 300 301 141 116 +24VGND 10

Star shorted contactor signal

Y6

PE 12

M3/2

JR3

NC

117

8

S1

PE

118B 9

Interface Board Location No.

X0

S6

6

Definition

XF(X24)

G5 M8

7

5

8

7

135 GND MX

115 G2

PE

6

MS

5

115B

5

5

130A130B MS(X1)MX(X2)110A 115 115A 141

+24VGND ZPS ZPX X22 X23 COM0 Y0

6

1

4

M6 1

115

2

3

M3

118B

12

1

G4

G1 13

4

141 116 GND YJ(X18)

116 117 118 118A 101 D

3

4

COM5

5

M7/7

6

Design Check Approve

QianJianqiang

Date

2016.5.14

Control Box Interface Board Plug-in Drawing

7

Draw No. TRF110 18 Sheets Sheet 2 Remark

8

1

2

3

4

5

6

G4 1 141 2 116 3 GND 4 YJ(X18)

D

J1

Main Control Board

C

J7-5 J7-2 J7-x J7-4 J7-1

High-platform (Main motor) Emergency Stop

B

Hand-wheel Switch

Up Run Overspeed Switch

Intercom

A

1

2

EPS13

2 3

Emergency Leveling Device D

4

G1 116 117 118 118A 101

1 2 3 4 5

G2 115b PE 115C 115C PE 115 115 PE 114a GB1 GB2 118A 118B

1 2 3 4 5 6 7 8 9 10 11 12 13

G3 P+ PR L

1 2 3 4

Fire Signal Temperature control signal Overload Signal

RA 1 GND 2 KBK1 3 KBK2 4 BK1 5 BK2 6

40pin bull socket

BL6 VER:1.0

1

G5 1 XF(X12) 2 WK(X21) 3 CZ(X25) 4 GND 5 GND 6 +24V

CN1

8

7

Brake Inspection

C

Brake

RB 1 114A 2 PE 3 114

Speed Governor Down Run Protection Switch

Interface Board E-KIB-A VER:2.0 1 2 3 4 5

G6 L31 N PE L35 N2

B

Car Light Power Input

D1 1 GND 2 130A 3 121(X5) 4 122(X6) 5 100(IN) 6 108 7 115A 8 116 9 117 10 118 11 118B

3

4

5

A

6

Design Check Approve

QianJianqiang

Date

2016.5.14

Control Box Wiring Terminal Circuit

7

Draw No. TRF110 18 Sheets Sheet 3 Remark

8

1

2

3

4

5

6

1 2 3 4 5 6 7 8 9

M1 GND 24V 116 141 300 301 201 200 101 100 M2

D

DC24V Power Input Phase Relay Safety Circuit Brake Power Input 220V Power supply for control circuit AC110V Power input

C

1 2 3 4 5 6 7 8 9 10

1 Y6 2 Y7 3 Y8 4 Y9 COM3 5 118 6 101 7 X17 8 X16 9 X11 10 GND 11 300 12 301 13 BK0 14 BK2 15

Running, Brake, Star shorted Contactor coil

Contactor adhesion inspection

Brake circuit

E-KIB-A VER:2.0

M3 130A 1 130B 2 MS(X1) 3 MX(X2) 4 110A 5 115 6 115A 7 141 8

B

Controller Inspection Box

M5 100 101 BK0 BK1 BK2 BK3 116

Brake-releasing 110V charging D

Brake power for brake release device

Door lock spare

118B BYX

Spare 1

M6 1 24V 2 GND1 3 ZPS 4 ZPX 5 X22 6 X23 7 COM0 8 Y0 9 116 10 117A 11 118B 12 GB1 13 GB2

Interface Board

118

8

7

Previous Door Opening Board Power Previous Door Opening/Releveling Zone input Previous Door Opening/Releveling Signal Inspection Releveling Zone Signal Input

C

Previous Door Opening Zone input

Door lock signal

Car door close inspection

M7 1 24V 2 24V 3 GND 4 GND 5 C+ 6 C7 COM5 8 Y11 9 COM4 10 Y10 11 LD1 12 LD2

Power supply communicate to main board B

Spare Spare Fire Linkage Output

A

A

1

2

3

4

5

6

Design Check Approve

QianJianqiang

Date

2016.5.14

Control Box Plug-in Circuit

7

Draw No. TRF110 18 Sheets Sheet 4 Remark

8

1

2

3

4

5

6

7

8

Control cabinet

D

D

1 2 3 4

Power input

Traction motor

PG-A2/E

DDZ U1 1 V1 2 W1 3 Note:Power supply for MRL is L1,L2,L3 N 4 PE 5

C

DDZ U3 V3 W3 PE

Encoder C

1 2 3 4 5

XDZ L32A L32B 201 XS1 XS2

Shaft light

MRL speed governor detection

B

B

A

A

1

2

3

4

5

6

Design Check Approve

QianJianqiang

Date

2016.5.14

Draw No. TRF110 18 Sheets Sheet 5 Terminal Circuit Remark

Control Box

7

8

1

2

3

4

5

6

8

7

D

D

1

2

3

4

+24V GND C+

C-

1

2

3

4

1

+24VGND BL1 BL2

CHM

2

3

4

5

6

7

GB1 GB2A BYX BY01 BY02117A 118

VB

8

9

S2

3 PE

GND +24V QZ

2

L31 N1

3

4

PE

P+

5

6

7

8

9

1

JL+ JL- YJ+ YJ-

P-

3

4

5

6

JL1 JL- P+

P-

R

L

EPS2

EA

TD 12

L31

N1

YJ-

JL+

JL1

200

201

R

L

YJ+

4

BZ

FA

ZPS ZPX BYX

JR1

1

P+

P-

N2

L33

105

CANPE

GND

C-

12

12

3

RDR

EM 3

1

GND

+24V

3

DR

GB1

6 ZM/FS 3

3

DMX

4

105

5

106

6

118

117 117A

111

7

100

108

110

8

110

PE

201

GND

200

LSB2_1

10

PE

LSB1_1

1

10

3

12

3

RGS

GS 117A

PE

PE

117A

201

EM

FA

PE

PE

200

N1

N1

118

117

SOS

RTES

108

111

KAB1

KAB2

1

7

P+

1

3 C+

2

DMS

L

DMS DMX SMQ

GB2A

E-CIB-A_V1

PE

R

XMQ 130

L35

P-

1

EB

1

130 15

3

CN1

100

GND TA 13

JR2

3

9

2

EPS1

10

9 PE

CZ

1

1

5

L35 N2

TB

JR0

C

4

VA

7

9 MZ

2

L31 N1

QGM1QGM2

BY

LWD 7 S3

1

4

1

C

CIB

1

CN2

B 12 TC

5 CN3

CANPE

C-

C+

HF

GM2 GND PE

1 GND 24V

GB

KM2

GMV2

201

CM2

KMV2 GB2A

200

10

S1 1

DM

3

9

DZ

3

GM GND PE

GB1

ZPX SMQ XMQ

KM

GMV1

201

ZPS +24V

PE

PE

CM1

KMV1

200

GND

111

106

10

GB

7

1

B

1

Jumper wire Definition

Factory setting

S1

Spare

Bridge joint

S2

Spare

Disconnect

S3

Spare

Disconnect

Name A

1

2

3

A

4

5

6

Design Check Approve

QianJianqiang

Date

2016.5.14

Draw No. TRF110 Car Top Interface Board 18 Sheets Sheet 6 Plug-in Cable Remark

7

8

1

2

3

CB0

HA

CB1

HB D

Control Cabinet E-KIB-A

CB2

HC

CB3

HD

CB4

HE1

CB5

TB

CB5

TA

HE2 TD

TC

CB5

TB

6

8

7

Hoistway Top Signal Cable Hoistway Bottom Signal Cable Hoistway Communication Cable

D

Pit Cable Front landing door Lock Cable Rear landing door Lock Cable

CB5

TC

5

Junction Box on Car Top

TD

RGS

COP Cable

CB9 CB10

TA

CB4b

4

C

DB5

SMJ C

RTES

EA

DB4

RDR

Rear Door Lock

DB8 DB8A

SDH

E-CIB-A Car Top Wiring

Rear Door Emergency Stop

EB

KAB2 Rear Door Light Curtain Box

LWD

DB1

DB7 DB7A

DB10

MZ

3

CZ

FAN

EM

Light Fan Leveling Zone and Previous door opening

2

DB11

DB10A

Light Curtain Box

Front Door Lock

A

1

DB9

MQ

KAB

SMJ

SNQ Safety Gear

DB2

CMM

CM1 KM2 GM2

GMV2

200 201 PE

DB3A

DB6

L N PE B2 B3 C2,C3 8 1 2

DB3

B

DB6A

L N PE B2 B3 C2,C3 8 1 2

B

CMM

LWD

CM1 KM GM

ZM/FS

GMV1

DZ

KMV1

DR

200 201 PE

GS

KMV2

RDM

DM SOS

U V W

U V W

DM

DM

Weight Switch A

4

5

6

Design Check Approve

QianJianqiang

Date

2016.5.14

Machine Room & Car Top Circuit

7

Draw No. TRF110 18 Sheets Sheet 7 Remark

8

1

2

3

4

5

6

7

8

EPS1

J4 D

L31 N PE

CN1

D

Car Top PBC BL2000-JDB

2 P+ PJL+ JLYJ+ YJ-

Intercom Power Input 1 J3

Intercom Power Input 2 Alarm Power Input 1 Alarm Power Input 2 Emergency Light Power Input 1 Emergency Light Power Input 2

CN2

4

4 CN3

J1

3 4 5 Car Top Emergency Power 6 7 8

1

1

EPS2 JL1 JLP+ PR L

C

P+

P+ PR L

PR L

EDM XD

SDM

VA L31 N1 PE

L31 N PE

VB 24V GND BL1 BL2

DZZ Power 1 DZZ Power 2 DZZ COM DZZ Output

BELL

Car Top Motor

1

Alarm Wiring Terminal 1 Alarm Wiring Terminal 2 Intercom Power Intercom Power Intercom Signal 1 Intercom Signal 2

Interface Board E-CIB-A

Car light socket

L35 N2

BY GB1 GB2A BYX BYO1 BYO2 117A 118 QGM1 QGM2

24V GND

Arrival Gong

T1 T2

C

Front car door close detection

KGB1 KGB2 Rear car door close detection

Bypass buzzer (Optional)

Rear door lock signal

DJ

B

B

11

12

13

14

130

21

22

DMS

DMG

DMS

CIB GND 130 DMS DMX

GND

DMX

DMX

Signal COM Inspection Signal Inspection Up Signal Inspection Down Signal

CHM 24V

24V

Voice Announcement GND C+ C-

GND C+ C-

Voice Announcement

SDT Car Top Emergency Stop 105

105 106 111 110

106 111 110

Car Top Emergency Stop 1 Car Top Emergency Stop 2 Car Top Inspection 1 Car Top Inspection 2

A

A

Design Check Approve Date

1

2

3

4

5

6

Draw No. TRF110 Car Top 18 Sheets 8 Sheet Interface Board Terminal Remark 2016.5.14

QianJianqiang

7

8

1

2

3

4

5

6

7

8

The definition of interface board and plug-in branch cable D

Plug (194017-1)

Car Top Interface Board

3m 2

Safety Gear Cable DB1 2 3*0.75mm (L=3m)

Plug SOS 1-480700-0

Pin

Wire No. in Drawing

3*0.75mm 3

1

111

2

Cable No.

SOS

1 2

111 PE

1 3

1

3

108

2

AMP 1-480700-0

2

PE

3

108

111

1

D

DB1

3

PE

2

108

SOS

3m 2

Plug (194017-1)

Car Top Interface Board

3*0.75mm 3

Front Door Lock Cable DB2 2 3*0.75mm (L=3m)

Plug GS 1-480700-0

Pin

Wire No. in Drawing

1

117

2

PE

2 GS 1

Cable No.

1

117

1

2

PE

3

3

117A

2

3 117A

117

1

DB2

3

PE

2

117A

GS

AMP 1-480700-0 3m Freight elevator rear door cable length add to 6m 2

3*0.75mm 3

Plug (194017-1)

Car Top Interface Board

C

RGS 1-480700-0

118

RGS 2

PE

2

Rear Door Lock Cable DB5 2 3*0.75mm (L=3m)

Plug

1

1 3 117A

Pin

Wire No. in Drawing

1 2

118 PE

1 2

3

117A

3

3m Freight elevator rear door cable length add to 6m 1

1

Plug (194017-1)

Car Top Interface Board

2

106

Pin

Wire No. in Drawing

1 2

106 PE

1 3

3

111

2

Plug (194014-1)

Car Top Interface Board A

111

111 200

Cable No.

1

200

2

201

3

2

1

6

PE

6

5

4

3

GB1

4

GB

9

8

7

12

11

10

Wire No. in Drawing

1

200

1

2

201

2

3

GB1

1

10 CM1

4

GB

2

11 KM

5

Empty

6

PE

3

7

KMV1

1

8

GMV1

7 KMV1

DM DM

AMP 1-480708-0

8 GMV1 9 GND

12 GM

9

GND

2 3

10

CM1

4

11

KM

5

12

GM

6

201

2

Pin

2

PE

2

3m

DB3

1

PE

B

2 3

KMV1

1 2

GMV1

3

GND

4

DB3A

5

CM1

6

KM

2

6*0.75mm

GM

3m A

QianJianqiang

2. Both ends of stripped-off cable length is 100mm, and cover number tube.

Design Check Approve

3. Cable plug-in is equipped with 350536-1 jack.

Date

2016.5.14

Note:1. Add DB4,DB5 cable for double entrance, freight elevator rear door cable length add to 6m.

type 7508 1

DB4

3

3*0.75mm

2

1-480708-0

PE

3

AMP 1-480700-0

Cable No.

3*0.75+6*0.75mm (L=3m)

DM

RTES 2

106

1

RTES

Front Door Operator Cable DB3 DB3A

Plug

117A

2

3*0.75mm (L=3m)

B

2

3*0.75mm 2

1-480700-0

PE

AMP 1-480700-0

Rear Door Emergency Stop Cable DB4

RTES

C

DB5

3

RGS

Cable No.

3

Plug

118

1

3

4

Draw No. TRF110 18 Sheets Car Top Interface Board 9 Sheet Plug-in Cable Remark

type 1.25-3 5

6

7

8

1

2

3

4

5

6

7

8

The definition of interface board and plug-in branch cable 3m Freight elevator rear door cable length add to 6m 2

Rear Door Operator Cable DB6 DB6A

3*0.75mm

2

3*0.75+6*0.75mm (L=3m)

D

Plug (194014-1)

Car Top Interface Board

Plug

RDM 1-480708-0

Pin

Wire No. in Drawing

Cable No.

1

200

1

2

201

2

3

GB

4

GB2A

5

Empty

6

PE

7 8

1

200

4

2

201

3

2

1

6

5

9

8

7

6

PE

12

11

10

3

GB

RDM

AMP 1-480708-0

3

7 KMV2

9

GND

1

10 CM2

GMV2

11 KM2

9

GND

10

CM2

4

11

KM2

5

12

GM2

6

DB6

201

DB6B

PE

4 GB2A

KMV2

2 3

D

2

RDM 8 GMV2

3

200

1

12 GM2

1 2

KMV2

3 4

GMV2

5

GND

6

DB6A

2

CM2

6*0.75mm

KM2 GM2

C

C

Front Door Light Curtain Cable DB7 DB7A 2

3*0.75+2*0.75mm (L=3m)

Plug (194014-1)

Car Top Interface Board

Plug

DR 1-480708-0

B

Pin

Wire No. in Drawing

Cable No.

1

200

1

2

201

2

3

Empty

4

Empty

5

PE

6

Empty

7

Empty

8

GND

9

KAB1

10

Empty

11

Empty

12

Empty

3m Freight elevator rear door cable length add to 6m 2

3*0.75mm 3

3

2

1

200

6

5

4

2

201

9

8

7

DR 5

PE

12

11

10

8 GND

DR

1 2

1

9 KAB1

1

Plug (194014-1)

Car Top Interface Board A

RDR 1-480708-0

6

KAB1

3m Freight elevator rear door cable length add to 6m

3m Freight elevator rear door cable length add to 6m

Cable No.

3

2

1

1

200

1

6

5

4

2

201

2

201

2

9

8

7

RDR 5

PE

3

Empty

12

11

10

4

Empty

5

PE

6

Empty Empty GND

9

KAB2

10 11

Empty Empty

12

Empty

2

B

2

3*0.75mm

200

8

GND

DB7A

2

2*0.75mm

1

7

PE

5

2

Wire No. in Drawing

201

3

AMP 1-480708-0

3*0.75+2*0.75mm (L=3m)

Pin

DB7

2

Rear Door Light Curtain Cable DB8 DB8A

Plug

200

1

8 GND

RDR

9 KAB2

DB8

2

201

3

PE

5 6

GND

DB8A

2

2*0.75mm

AMP 1-480708-0

3

200

1

KAB2

3m Freight elevator rear door cable length add to 6m A

1 2

Note:1. Add DB6, DB6A, DB8, DB8A cable for double entrance, freight elevator rear door cable length add to 6m. 2. Both ends of stripped-off cable length is 100mm, and cover number tube. 3. Cable plug-in is equipped with 350536-1 jack.

Design Check Approve

QianJianqiang

Date

2016.5.14

Draw No. TRF110 Car Top Interface Board 18 Sheets 10 Plug-in Cable Sheet Remark

type 7508

3

4

5

6

7

8

1

2

3

4

5

6

8

7

3m GND

The definition of interface board and plug-in branch cable

24V SMQ D

D

GND

Leveling Zone Cable DB9 2 6*0.5mm (L=3m)

Plug (194012-1)

Car Top Interface Board

Plug

Wire No. in Drawing

1

Empty

3

2

1

2

Empty

6

5

4

9

8

7

3

DZ 1-480706-0

2

6*0.5mm

Pin

4 5 6

Cable No.

XMQ

4

GND

1

24V

2

4 GND

DZ

AMP 1-480706-0

DZ 5

24V

6

SMQ

8

ZPS

9

ZPX

24V ZPS

2

DB9

3

GND

4 5

24V

6

ZPX

3

SMQ Empty

7

3 XMQ

1

GND

ZPS 、ZPX for advanced door opening or relevelling.

8

ZPS

5

9

ZPX

6

24V XMQ

C

C

3m

Plug Plug (194002-1)

Car Top Interface Board

Light Fan Cable DB10 DB10A 2 3*0.75+3*0.75mm (L=3m)

Pin

2

3*0.75mm

Wire No. in Drawing Cable

1

N1

1

2

FA

2

ZM/FS

3

PE

3

1-480704-0

4

N1

5

EM

6

PE

3

B

No. 3

2

1

6

5

4

1 2

N1 FA

3

PE

4

N1

1

5

EM

2

6

PE

ZM/FS

ZM/FS

AMP 1-480704-0

N

1

DB10

2

FA

3

PE

1

N

2 3

DB10A

2

3*0.75mm

EM B

PE *2

3m

*1:No need to make the chuck.

Over Full Load Cable DB11 2 3*0.5mm (L=3m)

Plug (194012-1)

Car Top Interface Board

Plug

Pin

Wire No. in Drawing

1

Empty

2

Empty

3

Empty

4

LWD 1-480706-0

GND

5

1

24V Empty

6 7 8

A

Cable No.

9

MZ

2

CZ

3

3

2

1

6

5

4

9

8

7

3*0.5mm 4 GND

LWD

AMP 1-480706-0

LWD 7

MZ

8

CZ

GND

1

DB12

2

MZ

3

CZ A

Empty

1. Both ends of stripped-off cable length is 100mm, and cover number tube.

Design Check Approve

QianJianqiang

Draw No. TRF110 Car Top Interface Board 18 Sheets Sheet 11 Plug-in Cable Remark

Date

2016.5.14

type 1.25-3

1

2

3

4

5

6

7

8

1-480706-0

Top Terminal 2

Top Terminal 1 2 Olivine Earthing 3 Top Limit

121

4 5

GND 113 114

COM Top Final Limit

6

114 113 SSJ Top Final Limit PE 121 GND SXV Top Limit 123 GND SDZ1 Top Terminal 1 119 GND SDZ2 Top Terminal 2 To be connected when speed ≥2.0m/s

118b NKTM E

Hoistway Cable CB1 2 6*0.75+1*1.5mm Plug

Pin

1 2 3 4 5 6 7 8 9

Control Box

C

HB 194012-1

Wire No. in Drawing

HB 1-480706-0

1 2

120 124 PE 122

Definition

Cable No.

2KTM 1KTM E

Bottom Terminal 2 Bottom Terminal 1

1KTM 118 E

Olivine Earthing 3 Bottom Limit 4 5 6

GND 108 109

Wire No. in Drawing

117 PE 116

1 2 3

HE1 1-480700-0

COM Limit

116 NKTM E

Cable No.

Definition

1 Olivine 2

Landing Door Lock

2KTM 1KTM E 1KTM 117 E

HE2 1-480700-0

Wire No. in Drawing

118 PE 118b

1 2 3

Door Interlock on F2

Door Interlock on F1

Cable No.

Definition

1 Olivine

Landing Door Lock

120 GND XDZ2 Bottom Terminal 2 To be connected when speed ≥2.0m/s 124 GND XDZ1 Bottom Terminal 1 122 GND XXV Bottom Limit 108 109 SXJ Bottom Final Limit PE

2

2

3

1

6

5

4

9

8

7

2 1

HA/HB

AMP 1-480706-0 1

Terminal 2 branch 6m Terminal 1 branch 5m Limit branch 3m Final limit branch 3m

Electric lock

A 3

B

Bottom door lock branch line 3m

XF

Pin

Door Interlock on FN

Fireman switch 1

HE 194017-1

Control Box

Hoistway Cable CB4b 2 2*0.75+1*1.5mm Plug

C

Door Interlock on F1

2.3m

HE 194017-1

Control Box

B

Pin

Door Interlock on F2

HE1/HE2

Design Check Approve

QianJianqiang

Date

2017.2.24

Draw No. TRF110 18 Sheets Hoistway Pit Circuit Sheet 12 (with limit) Remark

AMP 1-480700-0 2

3

4

D

Final limit branch 3m Limit branch 3m Terminal 1 branch 5m Terminal 2 branch 6m

Bottom Final

Hoistway Cable CB4 2 2*0.75+1*1.5mm Plug

Door Interlock on FN

Top door lock branch line 3m

LR Cable length of M.R.

1

7m for MR, 5m for MRL

Definition

LH Hoistway total height

HA

119 123 PE

Cable No.

1 5 9

PP

Control Box

HA 194012-1

D

Wire No. in Drawing

1 2 3 4 5 6 7 8 9

G5

1 2 3 4 5 6 7 8 9

GND

Pin

2

HA Hoistway Top Cable

HE2 1 2 3

8

7

X20

Plug

HE1 1 2 3

HE1 Front Landing Door Lock Cable

Hoistway Cable CB0 6*0.75+1*1.5mm

1 2 3 4 5 6 7 8 9

6

LT Overhead height-2.3m

HB Hoistway Bottom Cable

5

Floor height of N-1

4

Floor height of N-2

3

This cable use spare cable. Add it when there is two-circuit detection.

2

HE2 Rear Landing Door Lock Cable

1

5

6

7

8

A

1

2

3

4

5

6

8

7

PB3=5M

PB1=2M

PB2=3M 115e

Emergency Stop Rope Breakage Cable PB1 PB2 HD 109

P+

115b

L

R

PE PE

115d 115e 115b 115d

E-PIB-A PC-2

PE

PE

112

109

PE

113

112

8

9

10

11

L35 N2 PE 115e 115a 109 113 P+ P-

R

L

2

3

4

5

XDZ 6 7

Plug

Plug (1-480705-0)

P-

113

Pit Inspection Box

115a

D

2

3*0.75+3*0.75mm (L=3m)

PC-1

Pin

Wire No. in Drawing Cable

1

115e

1

2

115d

2

PC1

3

PE

3

1-480704-0

4 5

115d 115b

1

6

PE

3

1 115e

No.

2 115d 3

2

1

5

6

4

PC-1

PC-1

AMP 1-480704-0

2

3

PE

2

PE

3

2

3*0.75mm

4 115d

1

5 115b

2

6

3

PE

115d

1

PB1 115d

2

3*0.75mm

115b

PB2

PE

SKT2

P+ P- R L Pit Intercom

Plug (1-480705-0)

Pit Inspection Box Emergency Stop

XK Pit Socket

EKM Pit light

C

Pit Inspection Box

Buffer Cable PB3 PB4 2 3*0.75+3*0.75mm (L=3m)

Plug

Pin 1

109

1

2

112

2

PC2

3

PE

3

1-480704-0

4

112

1

5

113

2

6

PE

3

Cable No.

Wire No. in Drawing

1

109

1

109

1

2

113

2

113

2

3

115a

3

115a

3

4

115b

4

115b

4

5

P+

5

P+

5

6

P-

6

P-

6

7

R

7

R

7

8

L

8

L

8

PE

10

1 109

1

2 112 6

5

4

PC-2

3 PC-2

AMP 1-480704-0 Note: Cancel PB3 and PB4 cable when speed≤1.0m/s.

PE

2

PE

3

2

3*0.75mm

4 112

1

5 113

2

6

3

PE

112

1

10

3

2

1

6

5

4

9

8

7

12

11

10

PB3

C

112 2

113

PB4

PE

HD

Pin

1 2 3 4 5 6 7 8 9 10 11 12

Plug

B

HD 1-480708-0

9

9

A

2

Pit Inspection Box

1-480708-0

Wire No. in Drawing

Pin

Plug(1-480709-0)

Plug(194014-1)

Control Box Interface Board

HD

3

AMP 1-480708-0

8*0.75+1*2.0mm Round Cable B

109

No.

3*0.75mm

Hoistway Round Cable CB3

Plug

PB3=5M PB4=5M

Wire No. in Drawing Cable

Note: Make terminal 109 and 113 on CN1short circuit when speed

OL Fire

ND1

X CZ MZ XF JX

+24V

>

J1

JE1

3 2

+24V

JN1

ND17

2

1

D

1

BL2000-CEB SN2

SN24 4

1

2

6

7

8

9 10 11 12 14 15 16 17 J5

BL2000-HXJ-V9 Car LCD Display Conversion Board 3

3

2nd floor car call

ND2

+24V

3 JN2

2

J2

4

BY0

4

Overload BY1

3

16th floor car call

ND16

+24V

JN16

SN25 4

2

>

1

EB

AMP 1-480707-0

4 5 6 7 8 9

C-

9

24V GND C+ C-

C+

8

24V

7

EB 1 2 3

JE1

3 2

C

+24V

1

When there is vice-COP or disabled COP, add the plug-in, wire length is 6m.

BL2000-CEB

KM 4 VH4

3

Door Open Button

CANPE

+24V

Choose CH4 Plug-in according to different display board.

PE 105

J1

ND25

GND

3 6 Plug (1-480707-0)

2 5

1

SN16

J3

C

1

+24V

ND24

J2

BL2000-ZLB J2

J1 24V GND C+ C-

4

JE8 2

>

1

C-

J1

2

GND

24V

1

C+

J3

4

SDC Car emergency stop

SN32

J2 4

2

3

1

JE8 2 J2

100

+24V

ND32 1

GM 4

Equip 350218-1 pin in AMP plug.

B

2

6

5

4

9

8

7

12

11

10

EA

AMP 1-480709-0

Pin 1 2 3 4 5 6 7 8 9 10 11 12

3

Door Close Button

EA

1

Plug (1-480709-0)

3

+24V

Cable No.

J3

2 1

L33 EM FA

SJM1 SFA

P+ PR L YJ+

B

Light Fan

+

-

R

Call button

YC 4

呼 叫

L

3

Door Open Prolong Button +24V

Hands-free intercom (Wiring as actual intercom)

JL

2

J6

J4

3

ZS

Bypass button

ZY

Special button Fireman button

XFY

2

4

1

E. light

YJJL+ JL1

1

Alarm 1

JL+ JL1

Alarm button plug

J5 SJ

P+ PR L

By attendant button

4

A Add it when there is vice-COP or disabled COP, wire length is 6m.

Note: When there is vice-COP or disabled COP, make branch plugs for Indicator communication wire in main COP and extend additional wires. Wire length is 6m. Draw branch line from alarm button and make relative plugs, line length is 6M.

Design Check Approve

QianJianqiang

Date

2016.12.14

COP wiring

Draw No. Sheets Sheet Remark

TRF110 18 17

Draw branch line from connection line of intercom, press the wiring terminal and cover number tube, line length is 6M. 1

2

3

4

5

6

7

8

A

1

2

3

4

5

6

8

7

J1

SN17

To car top communication board J8

4 4

D

J9

3

1st floor car call

ND1

+24V

>

SN1

>

J1

JE1

3 D

+24V

2

JN1

ND17

2

1

1

BL2000-CEB

Car Indicator SN2

SN24 4

2nd floor car call

4

3 ND2

+24V

3 JN2

JE8 2

2

>

1

+24V

ND24

J2

1

BL2000-ZLB JP1 JP3

超载

SN16

JP2

4

JP4

16th floor car call

J1 24V GND C+ C-

C

3 ND16

+24V

JN16

SN25 4

2

>

1

J1

JE1

C

3 +24V

2

ND25 1

BL2000-CEB

KM

Indicator communication wire should be connected to main COP

4 3

Door Open Button

+24V

SN32

J2

4

2

3

1

JE8 2 J2

+24V

ND32 1

GM 4 3

Door Close Button +24V

J3

2 1

B

B

YC 4

Call button

+ R L

3

Door Open Prolong Button

Call

-

+24V

Hands-free intercom (Wiring as actual intercom)

JL

J4

2 1

Alarm

Add when there is vice-COP or disabled COP, the wire should be connected to main COP.

A

Design Check Approve Date

1

2

3

4

5

6

Draw No. Vice COP & Sheets Sheet Disabled COP circuit Remark 2016.12.14

TRF110 18 18

QianJianqiang

7

8

A