30 0 2MB
1
2
3
4
5
6
8
7
D
D
Q Main power switch
U1
L1
V1
L2
4
W1
L3
PT
KMC Mian control contactor 2 1
6
R
KDY Running Contactor 1 2
U
YASKAWA
3
S
5
Inverter
T
★Connedt to U, V, W of ELD U3
V
3
4
V3
W
5
6
W3
H1000 N N
★
TB2 IP
FR2000-STB
IG
J7-1
Y10 Up running
J7-2
Y11 Down running
S2
J7-3
Y12 Release
S8
J7-7
COM4
SC
J2-2
X11
MB
FE
J2-10
X19
M1 MC
B1
M2
B2
C
Main control board
J3-7
J7-9
S1
GND2
VS
A+
+12V 0V A
TB1
B+
B
BC
A1
Connect when there is a brake unit
31 KLZ
J7-10
GND3
J8-1
32
(+3)
AC
(-)
IG
J8-5
AO
J8-6
IG TB2 BO
B
BS+ +
+0
BU
IP
J8-2
PG
A-
BS-
Braking resistor
RZD
CDBR-4030
-0
≧37KW Inverter input power
3
4
S3
B
SC
IG
Note : The wires which have ★ should be connected to the ELD ,if without ELD ,leave them.
A
A
Design Check Approve
Main circuit
Date
TRA110 Draw No. 14 Sheets 1 Sheet Remark G7+Asynchronous motor
FUJI YIDA 1
2
3
4
5
6
7
8
1
2
3
4
5
6
8
7
D
D
Q Main power switch L1
U1
L2
V1
4
W1
L3
PT
KMC Mian control contactor 2 1
6
R
3 5
U V
3
4
V3
T
W
5
6
W3
LIFT
FR2000-STB J7-1
Y10 Up running
J7-2
Y11 Down running
0V A
PG
REV PB EN
J7-7
COM4
CM
J2-2
X11
30B
J2-10
X19
Y1 30C
Main control board
J7-9
+12V
PA
Y12 Release
J3-7
P0 CM FWD
J7-3 C
U3
Inverter
N ★
★Connedt to U, V, W of ELD
S
★
N
KDY Running Contactor 1 2
B
C
GND2
CMY
VS
12 31 KLZ
J7-10
GND3
32
Braking resistor
P+
11
RZD P0
J8-1 J8-2
CM
J8-5
PA0
J8-6
PB0
DB
B
B
Note : The wires which have ★ should be connected to the ELD ,if without ELD ,leave them.
A
A
Design Check Approve
Main circuit
Date
TRA110 Draw No. 14 Sheets 1 Sheet Remark FUJI+Asynchronous motor
FUJI YIDA 1
2
3
4
5
6
7
8
1
2
3
4
5
6
8
7
D
D
Q Main power switch L1
U1
L2
V1
L3
W1
N
PT
KMC Main control contactor 2 1 4
3
6
5
★
N
Running contactor
R
U
S
V
T
W
FUJI LIFT Inverter +OPC-LM1-PR FR-2000-STB
C
J7-1
Y10 Up running
J7-2
Y11 Down running
Control mainboard
J7-3
J7-7
Y12
Release
T1
U3
L2
T2
V3
L3
T3
W3
KDY Built-in Not applicable when there is an ELD
PO
+5V
CM PA+
0V A+
FWD
PA-
A-
REV
PB+
B+
PB-
B-
PC+
C+
PC-
C-
CN3
EN
COM4
★ Connedt to U, V, W of ELD
KDY L1
CM
X11
30B
J2-10
X19
Y1
J3-7
GND2
30C
J7-8
VB
J7-9
VS
PG
D+
PD+
D-
PDJ2-2
C
HEIDENHAIN1387
CMY 12 V2
31
J7-10 GND3
32
KLZ
11 P+
CM
B
A+
J8-7
A-
J8-8
B+
J8-9
B-
J8-10
DB
4 1
B
Braking resistor
RZD
3
CN4
2
Note : The wires which have ★ should be connected to the ELD ,if without ELD ,leave them. When the traction machine is "Diana" series, there must be an electric brake release device in the control cabinet, in that way, please connect the circuit which show "Applicable when there is an electric brake release device" in the drawing. A
A
Design Check Approve
Main control circuit
Date
TRA110 Draw No. 14 Sheets Sheet 1 Remark FUJI + synchronous motor
FUJI YIDA 1
2
3
4
5
6
7
8
1
2
3
4
5
6
8
7
Applicable when there is an electric brake release device
U1 V1 W1 Phase protection relay
KXX D
U1
V1
★power interlock input ★power interlock input
U1a
503
2
Main control contactor
R2
Running contactor
KMC 44 43
T2 S2
F4(1P4A) 380V
J5-3
200
X23-
1
SZ2 2
KDY 44 43
Door lock relay
Braking contactor
KMB 2
2
1
Connect when total floor number≥16
KLZ
Braking contactor
KJR 1
2
KLZ 1
A2
A2
KMB
X23+
KJT
AC
A1
A1
116
★
SMJ
116a
SM1
SM2
SM3
Landing door on 2nd floor
SMn
SMn-1
Landing door on N floor
118
★
C
Brake
LZ
BK2
Note: The brake voltage is according to the actual. When brake voltage is DC220V, rectifier "ZL1" is connected. When brake voltage is AC220V, jump the "ZL1".
F2(1P4A)
Applicable when brake voltage is AC220/DC220V 100b 100
Safety circuit
115c
BK1
102(-)
100a
★
117
★
SZ2 Applicable for Electric Brake Release of MRL Elevator KYJ 2 3 4
SDT
115b
KYJ
Emergency stop on car top
SJT Emergency stop in M.R.
1
1
2
504
505
B
105 115a
SMn-2
43
110
GJ
Main control contactor
SDC Emergency stop in car
SPS Jigger handwheel switch 115
KMC 44
Running contactor Door lock relay
44
KDY 43
Braking contactor
KMB 1
Connect when floor number≥16
KLZ 2
2
KJR 1
2
106
DJ
1
Braking contactor
BK1
LZ
RJ
SKT Emergency stop in pit
Emergency running Inspection
Door interlock loop
Landing door on 1st floor
118a
ZL1 注
★Braking input power ★
KXX Phase sequence
Car door switch
N
AC
+
103(+)
110VAC
o b n i a X22+ J5-1 m o T
3
4
d
r X22- J5-2 a
101
FR-2000-STB
d r a o b n i a M o T
FR-2000-STB
0VAC
F3(1P4A)
B
110VDC
220VAC
200a
201
4
Braking economic resistor
TC1 Control power transformer
J5-4
D
KYJ
1
RJ
0VAC
3
KYJ
V1a
F1(3P6A)Control power breaker
C
501
D1
Brake
BK2
KLZ 4
3
RLZ
Braking economic resistor
★Braking input power
★Brake input power
SCS Up running overspeed switch
Applicable when brake voltage is DC110V
114a SKS Rope break-off switch SXS Speed governor switch
Note : The wires which have ★ should be connected to the ELD ,if without ELD ,leave them.
111 114 SNQ Safety gear switch SSJ Top final limit
A
Brake Contactor
BLV+ P+
108
113
SXJ Bottom final limit SHC Buffer switch
C+
5
KLZ
Design Check Approve
6
LCD Counter
BLVP-
C-
Safety, Door Interlock, Brake Circuit
Date
109
TRA110 14 2
Draw No. Sheets Sheet Remark
FUJI YIDA 1
2
3
4
5
6
7
8
A
5
For elevator speed≥2.0m/s 2
GND2a
DJ
DMG COM Button on Car Top
130
L
Note: To be connected
N
SDZ2
XDZ2
SXV
Emergency running
GJ
Fireman switch Down limit zone
+24V
JXa
J4-4 J4-3 J4-2 J4-1
J3-10
Slow up in M.R. Slow down in M.R.
JX
MS
MX
X0
X1
X2
J3-7、8、9
J1-1
J1-2
119
DMS DMX
FMS FMX
★
GND2
44
KJT 5
KMB Door interlock
43
1
3
+5VGND3 +24VGND3
6
Emergency stop contactor
SMQ XMQ
+24Va +24V
CXF
2
photoelectric leveling switches
★
SXF
Up door zone XXV SDZ1 Bottom XDZ1 limit 1
FMG COM Button in M.R.
when there are ELD and
Switch power +5V -5V +24V-24V
Fire fighting motion
Top terminal 2 Bottom terminal 2Top limitBottom limitTop terminal 1
120
121
122
123
124
SMQa XMQa SMQ
Slow up at car top
★
XF
Electronic lock Locked when Break-off
KBK1 KBK2
44 Brake
KLZ 31
SDF
DF
WK
X20
X21
43
KDY 32
KBK
8
7
GND2
1 Inspection box oncar top
3
D
★
6
Connect when there is fire fighting function Fire fighting center
Opional
4
Thermal controller constant-close output
3
201
WK
2
200
Brake detecting switch
1
D
XMQ
Slow down at car top
X3
J1-3
X4
J1-4
FR2000-STB
X5
J1-5
X6
J1-6
X7
J1-7
X8
J1-8
X9
X10
J1-9 J1-10
X13
X12
J2-1
J2-3
X14
J2-4
X15
J2-5
X16 X17
J2-6
J2-7
J2-8
X18 J2-9
J3-1 J3-2
For rear door J6-9
Y6
Y9
KLZ
1
A2 21
Y8
A1
KJR
KDY Running contator
Braking contactor
2
KJT
C
Y7
A1
A1
Economic resistor relay
COM3
A2
KYJ
J6-5
J6-8
J6-7
COM2
KMC A2
J6-1 J6-2
J6-3 J6-4
Y2
Y4 Y5
Y3
J5-1 J5-2 J5-3 J5-4 X22+ X22- X23+ X23-
J4-5 J4-8
J5-10
J5-9
COM1
Y1
2H 2L
J4-6 J4-7 1H
1L
4 C
KJT
A2
3
LD1
22 6
LD2
Connect when there is fire fighting function
KMB
CM1
5
KM2 GM2
KM GM
24T
101
When using Blue Light SJT-FZ,leave them For rear door
GND1 C+ C-
CB+ CB-
GND1
Call box/COP Twin control/Group control communication wire communication wire
Safety, door lock circuit s testing
Connect when total floor number≥16
116
J4-9 J4-10
A1
Main control contactor
J6-6
J6-10
For rear door
RS-485 Serial weighing communication
24T GND1 C+ C-
1KAB2
Safety edge1
B
KQZ KKZ KCZ
KMZ
GMV2 KMV2
GMV1 KMV1
SZS
SZY
RT- RT+ 24V CMM
SZH
1KAB1
Note : The wires which have ★ should be connected to the ELD ,if without ELD ,leave them.
B
2KAB1
Safety edge1
CMM
QZ
J9-1
J1-1J1-2 J1-3J1-4
Spcial use switch Bypass switch By attendant switch
Safety edge 2
Door close limit 1Door open limit 1
Light loadNo load Overload Full loadDoor close limit2Door open limit 2
2KAB2 Safety edge2
KZ
J9-8
J9-9
CZ
GMV2 KMV2
MZ
J9-5
J9-6
GMV1 KMV1
J10-6 J10-5
J9-3
KAB
J9-2
KAB2
J9-4
J9-7
J10-1
J10-2
J9-10
J4-4 J4-3
J4-2
J10-7 J10-8 J10-9 J10-10
NCZB J11-1
BLV+ red
A
J11-2
J11-3
BL1 BEL
J11-4
J11-7 J11-8
J11-5 J11-6
DC24V
J3-4 J3-3
J3-2
J3-1
J4-1
J5-4 J5-3 J5-2
14
N
24V CMM
L31
BY1
+24V Door open button2
J5-1
J6-4 J6-3 J6-2 J6-1
GMD1 Door close light
+24V
SKY
SGM2
KMD2
GMD2
Door open light 2
Door close light 2
Design Check Approve
KYD
BY2
Control circuit
Date
3
4
5
TRA110 14 3
Draw No. Sheets Sheet Remark
FUJI YIDA
Door open holding light
Spare output 2
+24V
Door open holding button
Door close button 2
SKM2
SGM1 KMD1
BLV-
+24V Door close button
SKM1
Door open light
TC1 1
J2-1
+24V Door open button
CZD
KZM
Arrival chime
+
J2-2
ZM 13 Light control Overload light
yellow
F5(1P4A) black
J2-4 J2-3
6
7
8
A
1
2
201
3
For machine room less elevator
D
200
FXS
4
5
U
U5
V
V5
W
W5
6
L31
N
Door motor
SDM
T2a
N
N
T2
★
SKK
B2
KMV1(5)
J9-2
B3
GMV1(6)
J9-3
CMM(4)
J9-1
C
2
GM(3)
1
KM (2)
8
★
8
CM1(1)
Speed governor reset
T2
N
EKM
Pit light
L312
Pit lighting socket
NCZB COP mainboard
C2 C3
Speed governor motion
XD
Car top socket Pit light switch
Shenling VF Door machine XS2
EDM
Car top light
L311
L
D
Car top light switch
PE
XS1
8
7
XK
XG Control cabinet power socket KZM 21
Car light
SJM1
L33
22
EM
EM1
Car light switch
Car light
Lighting control relay
EM2
Car fan switch
SFA
Car fan
FA
FAN C
Running contactor Control fan
KDY 13 14
FAN1
The No. in paranthesis is cable No. of Shenling door machine Applicable when floor no. is above 6 Shaft light switch(M.R.)
F6(1P4A) 503
SZMf
L32
UPS
502
501
U
U6
V
V6
W
W6
Shaft light switch(pit)
2
N
SZMk 1
2
1
ECM1 Shaft light
Door motor 2
3
2
3
ECMn
ELY traction machine emergency lighting XJC Monitor power socket
L
T2a
N
N
T2
★
PE
Safe lighting breaker
TD3200 VF Door machine
XTC detector power socket B
Brake Release Contactor
PC1
A2 A1 KYJ Emergency Electric Operation GJ SZ1 Brake Release Button
PC2 PAC
Applicable when brake voltage is DC110V
KMV2
J10-5
GMV2
J10-6
CMM
J9-1
L3
L31
N
N
B
Q2
GM2
CD
L32
AC220V TC2
Q1
NCZB
KM2
OD
★
AC110V
N
CM1
COM
Shaft lighting breaker
AC
AC
ZL2
-
+
504
505 Note : The wires which have ★ should be connected to the ELD ,if without ELD ,leave them.
A
A
Design Check Approve
Door operator power supply terminals L/N shoud be connected to T2a and N when there is an ELD, but should be connected to 200 and 201 when there is no ELD.
Control circuit
Date
Draw No. Sheets Sheet Remark
TRA110 14 4
FUJI YIDA 1
2
3
4
5
6
7
8
1
2
3
4
5
6
8
7
When floor no. is above 30, cut off the power supply wire at the middle floor, otherwise connect it.
24T GND1 C+ CD
4
3
2
1
+24V
2
J2
NHTB 3
4
1
2
J3 3
+24V
4
1
J1
1
4
3
2
J1
NHTB J2 2
3
4
1
2
3
J3
+24V
201
+24V
4
1
2
3
+24V
200
1
4
3
2
J1
NHTB
AVR3 N
J2
L
4
Applicable when floor no. is above 30.
1
2
3
J3 +24V
4
1
+24V
2
J2
24V- 24V+
3
4
1
1
4
3
2
NHTB
J1
1
4
3
2
2 +24V
3
4
J3
NHTB
J1
1
D
C
C
Text Text
3rd floor up call
N floor down call N-1floor up call
3rd floor down call 2nd floor up call
Elevator A J4 6
BL-2000-STB
CB+
7
CB-
8
GND1
CB+
6
CB-
7
GND1
8
J4
BL-2000-STB
2 3
8
9
GND1
C+
4
1 4
J1 J2
3
4 3
Up call +24V
2
2
1
1
4
4
2
10 C-
5 24T
GND1 C+ 1
J4 10 C-
24T
Text B
8 9
1st floor up call
Elevator B
J4 5
2nd floor down call
3
B
4
J1 J2 NHTB
NHTB J3 A
3 2
3
Down call
+24V
J3
2
1
1
Design Check Approve
Landing call loop
Date
2
3
4
5
TRA110 14 5
FUJI YIDA
When two elevator are twin controled and use one common landing call button ,connect the wire as per this drawing and only connect the parallel wires. 1
Draw No. Sheets Sheet Remark
6
7
8
A
1
2
3
4
5
6
8
7
D
D
FR2000-STB J4 8
SN9
J12 SN1 4
24T
C+
C-
5
GND1
9
Optional function
4
>
10
>
3
1st floor car call
ND1
+24V
J1
JE1
3
9th floor car call
+24V
2
JN1
ND9
2
1
1
NEB SN2
SN16 4
4
3
2nd floor car call
ND2
+24V
3 JN2
JE8 2
2
>
1
C
16th floor car call
+24V
ND16
J2
1
C
NCZB SN3
SN17
1
J1 FR2000-CZB COP 7
8
J10 9
3rd floor car call
C-
2
C+
3
+24
4
GND
4 3 ND3
+24V
4 JN3
>
2
J1
JE1
1
2
3
4
1
ND17
2
3
1
4
NEB
Terminal
J1
SN8
SN24
CMM
24V
RT-
RT+
4
8th floor car call
Voice announcer
Car indicator
17th floor car call
+24V
2
1
10
3
4
3 ND8
+24V
JN8
JE8
2
3
>
J2
24th floor car call
+24V
2
1
ND24 1
B
B
>
Weighing
A
Design Check Approve
Car call loop
Date
Draw No. TRA110 14 Sheets Sheet 6 Remark
FUJI YIDA 1
2
3
4
5
6
7
8
A
2
0V
J1-3
N
+5V
J1-4
1H
FR-2000-STB
J1-6 J1-7
1H 1L
J4-7
J4-7
GND1
J4-8
CB+
Elevator B
CB-
J4-8
GND1
J1-8
GND1
CB-
GND1
CB+
J4-8
J4-6
1L
J4-7
D
FR-2000-STB
1H
J4-6
1L
Elevator A
8
7
GND1
Elevator H
CB+
L
FR-2000-STB J4-6
6
CB-
N
5
BL2000-QKB
AVR2
(4A) AC220V
D
4
GND1
F7 L1
3
Group control board
1
Group control system loop:
The terminal can be placed near to the control cabinet Suggest that there be no radiation equipment nearby
FR2000-STB
SJT-WJ
SJT-WK 4
+5V
5V
8
GND3
GD
9
C+
H
10
C-
L
C
J4 Wireless remote control system loop:
Monitor center 1 C
DC5V/1.5A
Power
SJT-WJ
Monitor center 2
Wireless network DC5V/1.5A
Power
Control cabinet
FR2000-STB Wire remote control system loop:
3
GND3
3
4
+5V
4
9
C+
9
10
C-
J4
B
BL2000YXZDB J1
SJT-YCJ 6
YH
H
7
YL
L
J1 8
YG
G
Monitor center B
10 Network
(Every control cabinet use one of this)
Control cabinet Power
FR2000-STB IC/ID card management system loop : J4
GND3
3
4
+5V
4
9
C+
9
10
C-
BL2000KIC/KID J1
SJT-QIC/QID 6
YH
H
7
YL
L
J1 8
YG
G
IC card reader MF-500
Monitor center
10
4 C-
GND1
24T A
C+
GC-1 2 3
1
3
Note:one monitor system use one data collector it can monitor several elevators.
Network
(IC/ID card network controller )
ID card reader YX-K4-232
Control cabinet
Design Check Approve
Power 1
2
3
4
J2 BL2000-CIC/CID Car IC/ID controller
Optional function loop
Date
Draw No. Sheets Sheet Remark
TRA110 14 7
FUJI YIDA 1
2
3
4
5
6
7
8
A
1
2
3
4
5
6
8
7
D
D
Power supply box AC220V Alarm Light Phone
+ -
+ -
+ -
Main unit on car top
Main unit in MR
+
-
R L
+
-
R L
Main unit in guard room
Main unit in pit
+
-
R L
+
-
R L
Sub-unit in cabin Black Red
Blue Yellow
Call
EYJ
Alarm
JL-
JL1
JL+
B1 C
C B2 B3
AC220V
Intercom for 5 ways
B
B
A
A
Design Check Approve
Intercom loop
Draw No. Sheets Sheet
TRA110-B 14 8
Date
FUJI YIDA 1
2
3
4
5
6
7
8
1
2
3
4
5
6
8
7
200
Top final limit switch
D
SSJ D
100
Top limit switch
SSV
Top terminal switch
SSD
Top sub-terminal switch
*1
SSD2
*2 200
Bottom final limit switch Bottom limit switch
SXJ
SXV
C
C
100
Bottom sub-terminal switch
SXD2 *2
Bottom terminal switch
SXD *1
Leveling position
Leveling zone switch
SMQ
XMQ
SMQ
XMQ
H Car
(Unit:mm ) Shelter board H1 B
UP
ELevator have to finish hoistway learning before high speed running. The conditions below are neccesary before hoistway learning: 1.Top/bottom limit switch and top/bottom terminal switch are installed ,connection is correct. 2.Up/down leveling zone switch and shelter board are installed ,connection is correct. 3.Safety circuit and door interlock circuit are normal. 4.General parameters and running parameters have been set. 5.Elevator can perform inspection running. 6.If inverter is YASKAWA G7 and above 18.5KW ,please check if the junction of inverter braking unit in the bottom left corner of the control cabinet is on 415V(Open the grey cover). Before hoistway learning, the system should be in inspection state and elevator should press the bottom limit switch.If elevator don't located at the bottom limit position,"To Down Limit"will be displayed Press slow down button as to move the elevator to bottom limit.If elevator is at bottom limit and " Enter To Start" is displayed(Elevator State:Up leveling zone X9 is valid,down leveling zone X10 takes off from shelter board ),press "Enter" key,elevator starts to perform hoistway learning(Elevator state : bottom limit X6 is reset ,then down leveling zone X10 come into the leveling zone).Hoistway learning stops at top limit (Elevator state:when arriving the top floor , up leveling zone X9 takes off from shelter board ,then top limit switch act )."Success" will be displayed if hoistway leaning is finished successfully.Please strictly perform hoistway learning according to the steps above ,otherwise hoistway learning may fail."Failure LER=#" will be displayed if there is a fault,you should solve the problem by fault code at first. If you want to escape from hoistway learning ,press "Esc" key,then "LER=15" displayed.
A
B
DOWN
Speed
0.5m/s
Item
1.0m/s
1.6m/s
2.0m/s
2.5m/s
230
2500 4000 230
2500 6250 230
250
250
250
*1 *2 H
1000
1300
2500
180
180
H1
200
200
Design Check Approve
Signal collection system
Date
Draw No. TRA110 14 Sheets Sheet 9 Remark
FUJI YIDA 1
2
3
4
5
6
7
8
A
1
2
3
4
Control cabinet GC-1
D
Terminal
Terminal
XDZ No.
Mark
No.
1
L31
31
U1
32
U1a
2 3
L32
N
D
Car top inspection box
Car top junction box
CB5
SDT 100
33
V1
34
V1a
DC-1 DC-2
DC-3 L31 1 2 L31 N 3
1
24T
1
2
GND1
2
3
C+
3
N
4
C-
4
122
36 118a
5
L33
5
105
5
110
116
37 115b
6
6
L313
6
111
38 115c
7
7
EM
7
8
FA
8
9
CMM
9
KMV1
10
121
6 7 8
117
Limit
Door interlock
9
118
39 100b
8
10
100
40 JXa
9
114
41 JX
Safety
12 115a 13 115 14 130 Inspection 15
DF
16
B1
17
B2
18
B3
42 KM 43 GM 44 CM1
Electronic lock
DC-9 DC-10 DC-11
200
10
201
10
11
100
11
GMV1
11
12
106
12 KAB
12
13
108 110
13
BL1
13
14
14
CZ
14
15
45
GND2a
46
+24Va
15
111
47
SMQa
16
15
116
MZ 16 +24V
16
48
XMQa
17
117
17
KMV2
17
19
49
SMQ
18
GND2
18
GMV2
18
20
50
XMQ
19
GND2
19
KAB2
19
51 T2 52 T2a
20
130
20
21
MS
53
22
MX
20 CM1 21 KM2 22 GM2
54
23
SMQ
55 56
24
XMQ
23 B1 24 B2 25 B3
21 BKB 22 WK 23 BK1 24 BK2 25 201 26 XS1 27 XS2
Intercom
Brake detection Temperature Detection
Brake Optional For machine room less and two direction speed governor
25 BLV26 BLV+
57
28 GND1
58
29 CB+ twin control
59
30 CB-
26
ZM 28 CM1
+24Va
28 T2a
29 KM
29
SMQa
30 GM
30
XMQa
200
201
CMM
1 DMS 2
2
116 117
3
T2a
4
N
5
CMM
6
GMV1
7
KMV1
MX
8
KAB
MS
9
KM
10
GM
11
CM1
12
(E)
1 DJ
DMX
EDM SDM L31
XD
N
Remark 2
SMQ
Remark 3
XMQ
GND2
Mark
1 2 3 4 5 6 7
U1 V1 W1 N U3 V3 W3
8 9 10
C
WECO light curtain connection
CB8 111
SNQ
No.
107 108
SNC
1
117A
2
117
3 KMZ
4
N
22
CZ
KCZ
5
CMM
23
CMM
6
GMV2
24
EM
EM1 EM2
27
FA
28
N
FAN
7
KMV2
8
KAB2
9
KM2
Mark Remark
1 2 CMM
T2a
MZ
30
Connected to 200 and 201 when there is no ELD
Door operator cable1
21
29
DDZ No.
13
25 26
GND2a
27
27
60
TB7
3 GND2/
Power terminal
Door operator cable
2
130
4
GND2
5
1
105
JL+ JL1
35 116a
4
11
B
CB5
8
7
CB3
Mark
COP cable CB9
C
CB5
XDZ
6
CB2
GC-4 GC-7 GC-3
GC-2
5
Connected to 200 and 201 when there is no ELD
Signal
3 KAB 4
200
5
PE
6
201
Power B
10 GM2 11 CM1
JL1
12 (E) ALARM
13
JL-
KAB
Remark 1: Connected to GND2a when there is an ELD, otherwise connected to GND2
DZ-2
DC12/24V
Remark 2: Connected to SMQa when there is an ELD, otherwise connected to SMQ
Arrival chime Black(-) Red(+)
L
N
COM
A
Remark 3: Connected to XMQa when there is an ELD, otherwise connected to XMQ
Yellow(spring)
A
A
Design Check Approve
BL1
BLV+
BLV-
Power box of light curtain
Car top circuit
Date
Draw No. TRA110 14 Sheets Sheet 10 Remark
FUJI YIDA 1
2
3
4
5
6
7
8
1
2
3
4
5
6
GC-7
D
Hoistway cable CB3 2 24*0.75+1*2.0mm
C
Plug (171830-1) Pin(170308-1)
Control cabinet
Plug
GC-7 171364-1
No.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Wire No.in drawing
L31 N
119 121 123 120 122 124 GND2 108 114 117 118 XF DF
E 111 106
18 19 20 21
1 2 3 4 5
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
GND2
Top limit Top terminal 1
117 NKTM E
Bottom terminal 2 Bottom limit
3KTM 2KTM E
Bottom final limit Top final limit
2KTM 1KTM E
Door interlock Fire switch Electronic lock
Earthing
1KTM 118 E GND2
Control cabinet Plug(1-480705-0)
24T GND1 C+ CE
GC-4 1-480704-0
SDZ2 Applicable when speed above 2.0m/s nth floor door lock
2F
2nd floor door lock
HTB J1 CH-4
1st floor door lock Applicable when speed above 2.0m/s XDZ2
GND2
1F
Intercom
XDZ1
122
23
GND2
XXV
24
108 109 DF
SXJ
Cable No. 1 2 3 4 Shield
Wire No. in Pin No. drawing
1 2 3 4
Plug
109 113
L31 N Light and socket in pit
Buffer SHC
B
HTB J1 CH-4
DF
XF GND2
spare
24T GND1 C+ CE
C
3th floor door lock
124
2*2P*0.75 drawing
SDZ1
120
Pit emergency stop
Landing call serial communication cableCB2 Wire No. in
HTB J1 CH-4
SXV
Bottom terminal 1
17
20
SSJ
123 GND2 119 GND2
Top terminal 2
Olivine 19
114 113 121
Pit
GND2
1 2 3 4 5
D
Cable No.
21 22
Pin No.
GC-4
nF
B
Plug
8
7
SXF
E 111106 Pit emergency stop SKT and rope breakage switch SKS
CH-4
When there is a rear door opening on one floor or more ,sub-door landing call subcircuit and main door landing call subcircuit shuld be parallel connection. When there is a rear door opening on one floor or more ,sub-door interlock subcircuit and main door interlock circuit should be serial connection. A
Design Check Approve
Hoistway circuit
Date
Draw No. TRA110-B 14 Sheets Sheet 11 Remark
FUJI YIDA 1
2
3
4
5
6
7
8
A
2
3
4
5
Traveling cable CB5 36*0.75+4 core shield
4
C-
shield 4
C-
4
E
shield
E
shield 1
GND1
C+
3
4
C-
shield 4
C-
4
E
shield
E
5
1
1
CMM
2
GND2
white 2
GND2
2
2
3
130
white 3
130
3
4
MS
white 4
MS
4
5
MX
white 5
MX
5
6
SMQa
white 6
SMQa
6
7
XMQa white 7
XMQa
7
8
CM1
white 8
CM1
8
DC-2
9
KM
white 9
KM
9
171358-1
GM
white 10
GM
10
Car top
Car top
+24V
Plug(172347-1)Pin (170308-1)
white 1
BLV-
DC-10
CMM
1
KMV1 white 2
KMV1
2
3
GMV1 white 3
GMV1
3
4
KAB
white 4
KAB
4 5
5
CZ
white 5
6
MZ
white 6
MZ
6
7
KAB2
white 7
KAB2
7
8
KMV2 white 8
KMV2
8
JC-10
9
GMV2 white 9
GMV2
9
171358-1
10
BLV+
white 10
BLV+
10
white 11
BL1
11
white 12
N
12
171358-1
11
11
BLV+
12
12
N
yellow 12
ZM
13
13
ZM
100
orange 1
100
1
1
2
106
orange 2
106
2
2
3
108
orange 3
108
3
3
B1
white 11
BLV+
white 12
13
ZM
1
white 1
yellow 12
ZM
2
orange 2 orange 3
B1
orange 4
B2
4
orange 5
B3
5
3
110
orange 4
4
4
5
111
orange 5
111
5
5
B3
6
116
orange 6
116
6
6
orange 6
6
7
117
orange 7
117
7
7
orange 7
7
8
L31
orange 8
L31
8
8
orange 8
8
9
N
orange 9
N
9
9
orang 9
9
L33
orange 10
10
DC-3
11
KM2
yellow 1
KM2
11
171364-1
12
GM2
yellow 2
GM2
12
13
13
yellow 3
200
14
yellow 5
201
15 16
14
200
yellow 4
15
201
Car top
4
10
171364-1
B
10
orange 10
10
JC-9
11
yellow 1
11
171364-1
12
C
13
B2
DC-9
D
1
orange 1
110
L33
JC-11 1-480704
CZ
BL1
12
2
shield 3
+24V
Plug
1
C+
1
BLV-
24T
shield 2 GND1
3
5
Plug(171830-1)Pin(170308-1)
Orange 11、12 earthed
Control cabinet
171364-1
24T
2
Pin No.
1-480704
5
171358-1
GC-3
1
Wire No. in drawing
Plug(1-480705-0)
3
Cable No.
Pin No.
COP
C+
1-480704
DC-11
Wire No. in drawing
Plug(172347-1)Pin(170308-1)
shield 3
DC-1
Plug(172347-1) Pin(170308-1)
Control cabinet
Plug(172347-1)Pin(170308-1)
GC-2
B
Plug(171830-1) Pin(170308-1)
2
C+
11
1
1
3
10
A
24T
shield 2 GND1
1-480704
5
C
Shield 1
12
yellow 2
13
105
yellow 3
105
13
14
106
yellow 4
106
14
15
L33
yellow 5
L33
15 16
16
B1
yellow 6
B1
16
FA
yellow 6
FA
17
B2
yellow 7
B2
17
17
EM
yellow 7
EM
17
18
B3
yellow 8
B3
18
18
JL+
yellow 8
JL+
18
19
GND2a
yellow 9
GND2a
19
19
JL1
yellow 9
JL1
19
Design Check Approve
20
+24Va
yellow 10 +24Va
20
20
yellow 10
20
Date
21
T2a
yellow 11
21
21
yellow 11
21
2
T2a
8
COP
GND1
Plug
Plug(1-480705-0)
24T
2
Plug
Plug(1-480705-0)
1
Pin No.
Car top
GC-1
Cable No.
7
COP cable CB9 36*0.75+4 core shield
Plug(171830-1)Pin(170308-1)
D
Pin No.
Wire No. in drawing
Orange 11、12 earthed
Plug(1-480705-0)
Plug
Wire No. in drawing
6
Plug(171830-1)Pin(170308-1)
1
3
4
5
A
Traveling cable
Draw No. TRA110-B 14 Sheets 12 Sheet Remark
FUJI YIDA 6
7
8
1
2
3
4
5
6
8
7
JC11 Plug(350536-1)
D
Plug(1-480705-0)
Pin No. Wire No.
1 2 3 4 5
24T GND1 C+ C(E)
D
TVVP4
6
JC10
1 2 3 4 CH-4
C
1 2 3 4 5 6 7 8 9 10 11 12 13
J9-1 J9-2 J9-3 J9-4 J9-5 J9-6 J9-7 J10-5 J10-6 J11-1 J11-2 J11-3 J11-4
CMM KMV1 GMV1 KAB CZ MZ KAB2 KMV2 GMV2 BLV+ BL1 N ZM
CZD
CZB
Plug(172347-1)Pin(170308-1)
Pin No.Wire No.
JC09
J11-7
J11-9
J10-10
J11-8
KMD1
J1
1 2 3 J2
J6-1 J6-2 J6-3
SKM1 4
Close door GMD1
J10-7 J10-8
Open door
RT+ CMM
4
J10-9
1 2 3 J4
CZB-01
J9-1
SKM2 4
For rear door Close door GMD2 Intercom (C.O.P.)
Plug(171830-1) Pin(170308-1)
B
A
3 4 5 6 7 8
B1 B2 B3 B4 B5 B6
YELLOW(12V-) BLUE(R) RED
RT-
SGM2
Call button
1 2 3 J5
JN1
RS-485 Serial load communication C
24V
J10-10
KMD2
B1 B2 B3
SKY Door open delay
1 2 3 J3
SGM1
SPARE
CH-4 1 2 3 4
KYD
J6-4
Pin Wire No. 1 2
Car indicator
J1
Open door
CMM
Special
J10-1
SZY
J10-2
SZS
Bypass
J9-10
SZH
By attendant
1 2 3
ND1
1st floor car call SN1
4
4 1 2
BLACK
ND8
JN8 3
B4 B5 B6
8th floor car call B
SN8
4
J1 J12
CZB-EB J2
9 10 11 12 13 14 15 16 17 18 19 20 21
J1 105 106 L33 FA EM JL+ JL1
SDC Emergency stop in car
105 106 L33 FA EM
SFA SJM1
JL+ JL1
JL
CZB-EB J2
Fan
Alarm
A
Design Check Approve
Note : 1. After the COP wiring is finished ,the plug should be made by the drawing. 2. The drawing is for BEST intercom ,Laogang intercom has different wire connection ,wire No. B1-B6.
COP wiring
Date
Draw No. Sheets Sheet Remark
TRA110 14 13
FUJI YIDA 1
2
3
4
5
6
7
8
C
1 2 3 4 5 6 7 8 9 10 11 12
100 115b 100b 115C 116 118 116a 118a GND2a JXa GND2 JX
Cable No.
Plug B
Control Cabinet
115C
B2
Wire No. in Pin No. drawing
1 2 3 4 5 6 7 8 9 10 11 12
+24V +24Va GND2 SMQa SMQ XMQa XMQ CM1 KM GM N
ELD Wire No. Pin No.
1 2 3 4 5
B1-5 B1-6 B1-7 B1-8 B1-9 B1-10 B1-11
12
B1-12
Cable No.
1 2 3 4 5
Plug
Plug
1 2 3 4 5
B1-1 B1-2 B1-3 B1-4
6 7 8 9 10 11
WS ELD Cable 12*0.75
6
6 7 8 9 10
B1
11 12
B3
No. in Pin No. Wire drawing
1 2 3 4 5 6 7 8 9 10 11 12
U1 V1 W1 N U1a V1a T2 T2a U3a V3a BK1 BK2
Cable No.
D
ELD Wire No. Pin No.
B3-1 B3-2 B3-3 B3-4
1 2 3 4 5
B3-5 B3-6 B3-7 B3-8 B3-9
6 7 8 9 10 11
B3-10 B3-11
12
B3-12
Plug
1 2 3 4 5 6 7 8 9 10
B3
11 12
ELD Wire No. Pin No.
B2-5 B2-6 B2-7 B2-8 B2-9
6 7 8 9 10 11
B2-10 B2-11
12
B2-12
Plug
1 2 3 4 5
B2-1 B2-2 B2-3 B2-4
6 7 8 9 10
B
Note: Control cabinet adopts sockets with 12 pin, cable adopts plugs with 12 jack. B2
11 12
Design Check Approve Date
2
C
B2
A
1
8
7
WS ELD Cable B3 12*0.75
Control Cabinet
Control Cabinet
B1
Wire No. in Pin No. drawing
5
B1
WS ELD Cable 12*0.75 Plug
4
ELD
D
3
ELD
2
ELD
1
3
4
5
6
ELD plug
Draw No. Sheets Sheet
TRA110 14 14
2010.10.1
7
8
A