35 0 4MB
VOYAGE DATA RECORDER MAINTENANCE SOFTWARE MANUAL ( Maintenance Software Version
Ver.
2.0.0 B)
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
Contents 1.
Maintenance Software......................................................................................................................... 1
2.
The Setup / Inspection Procedure ....................................................................................................... 3
3.
Functions............................................................................................................................................. 4
4.
Starting the Maintenance Software...................................................................................................... 5 4.1 4.2 4.3 4.4 4.5
5.
Setup of RCU 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8
6.
- DAU (D) - ............................................................................................................. 25
Setting Item .............................................................................................................................................................25 Procedure ................................................................................................................................................................26 Common Buttons.....................................................................................................................................................26 Identification ............................................................................................................................................................27 System ....................................................................................................................................................................28 Serial .......................................................................................................................................................................29 NAV- Interface .........................................................................................................................................................34 Contact ....................................................................................................................................................................36 Analog .....................................................................................................................................................................37 Ethernet .................................................................................................................................................................40 Configuration .........................................................................................................................................................42
System operation check .................................................................................................................... 43 7.1 7.2 7.3 7.4 7.5 7.6
8.
- RCU (C) -............................................................................................................... 9
Setting Items..............................................................................................................................................................9 Procedure ................................................................................................................................................................10 Common Buttons..................................................................................................................................................... 11 Identification ............................................................................................................................................................13 System ....................................................................................................................................................................14 Ethernet ...................................................................................................................................................................18 Configuration ...........................................................................................................................................................20 Capsule ...................................................................................................................................................................23
Setup of DAU 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 6.10 6.11
7.
Procedures ................................................................................................................................................................5 Preparation check, HVR Setup “HVR (H)” .................................................................................................................7 Quitting the Maintenance Software............................................................................................................................7 Password...................................................................................................................................................................8 Re-Log In...................................................................................................................................................................8
NMEA Sentence Monitor - DAU (D) - ..................................................................................................................43 Radar Image Monitor 1 - FGB (F) - ...................................................................................................................45 Radar Image Monitor 2 - Radar (R) - ..................................................................................................................47 Audio Monitor - AUDIO (A) - ..............................................................................................................................48 Event Monitor - Event (E) -..................................................................................................................................49 Dry Contact Data Monitor - Dry Contact (C) -........................................................................................................51
Record Data Check ........................................................................................................................... 55 8.1 Download of capsule Record Data - HVR backup (H) -.......................................................................................55 8.2 Conversion of Record Data - Data Convert (V) -.................................................................................................57 8.3 The Data Playback - Playback (P) - ....................................................................................................................60
9.
Factory-shipments setup ................................................................................................................... 61 9.1 FGB Maintenance WEB - FGB (F) -....................................................................................................................61 9.2 Setup of the DSC (NCT-57/63). - Dry Contact - ....................................................................................................63
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
i
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual 9.3 Setup of Analog Signal Input Unit (NQA-4091A)
10.
Troubleshooting and Utility ................................................................................................................ 75 10.1 10.2 10.3 10.4 10.5 10.6 10.7
11.
- Analog - ...............................................................................72
Control function - Control (R) - ............................................................................................................................76 System Satus display - System status (S) -.....................................................................................................79 System Log display - System Log (L) - .............................................................................................................86 Event Log display - Event Log (E) -...................................................................................................................87 System Configuration file in the PC card - Config (C) - .....................................................................................89 Converting “Log” to text - Log to TXT (T) - ........................................................................................................90 Program version of Maintenance Software - Version (A) - ................................................................................91
Program Upgrade.............................................................................................................................. 93 11.1 Program Upgrade - Version up (U) -..................................................................................................................93 11.2 FGB Program Upgrade - FGB (F) -.................................................................................................................95
12.
Installation of Maintenance Software................................................................................................. 97 12.1 Selection of languages ..........................................................................................................................................97 12.2 Installation procedure ............................................................................................................................................97 12.3 Upgrade...............................................................................................................................................................100
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
ii
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
1.
1. Maintenance Software
Maintenance Software
The maintenance software of JCY-1700 is a PC-based application. It serves the purpose of configuring and inspecting the product at the factory. On board the ship, it helps users to install the JCY-1700, change its settings, do its operational checkup, and to find the causes of malfunctions, if any.
Maintenance Software Version 2.0.0B ●
The latest Maintenance Software (Ver 2.0.0B) is applicable to the maintenance of both the JCY-1700 and JCY-1700S. The VDR model to maintain is chosen at startup of Maintenance Software.
●
When the software of RCU and DAU is updated to “2.0.0”, some added functions are able to be operated. The following added functions cannot be operated in case of maintaining the RCU and DAU installed old software. • RCU setup: Capsule setting function • DAU setup: Serial screen → Watch function Added items (AIS,DCNT+A/D) of TYPE function The software of RCU and DAU is updated for adapting to S-VDR and additional option units.
1)
Software name: JCY1700-maint.exe
2)
Language used for display: English * Only the event log screen can be switched to Japanese.
3)
Characters used for entry: English one-byte characters only The number of characters that can be entered is limited by each entry field. Any character over the maximum allowable number is rejected.
4)
Installation of the maintenance software: Use “setup.exe” for installing this software to the maintenance PC. Refer to Paragraph 12 for the installation method of this software.
5)
OS: Windows 2000, Windows Xp * This software does not run on the Windows 95 / 98 / Me.
6)
PC: Minimum requirements for a lap top PC: CPU: Pentium III 1GHz or more When the PC of low specification is used, do not use monitoring functions (NMEA, Audio, Radar) simultaneously. PCMCIA card slot: PC card as a data backup medium of VDR Communication I/F: Ethernet (10/100Mbps) 1024×768 (XGA) Screen resolution :
7)
Personal Firewall
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
1 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
1. Maintenance Software
In using the personal computer which enables the personal firewall function, use the maintenance software after disabling it.
●
Personal Firewall A personal firewall is a filtering facility of LAN communication link attached to OS (Windows Xp) and the software for a virus countermeasure.
●
When a personal firewall is enable. The VDR becomes impossible to communicate to the maintenaunce PC by a firewall function.
8)
Other requirements for maintenance: LAN cable (Builds in the RCU.) →Makes LAN connection from the Maintenance PC to the HUB unit of the RCU.
-------------- ABBREVIATIONS --------------Some of the abbreviations commonly used in this manual are: Abbreviations
Name
Type
HVR RCU DAU MCB FGB ARB DCB DSC AIU
Capsule Recording Control Unit Data Acquisition Unit Main Control Board of RCU Frame Grabber Board of RCU Audio Recording Board of RCU Data Control Board of DAU Digital Signal Converter Analog Signal Input Unit
NDH-288B NDV-132 NCT-58 CDJ-2142 CKA-129 CHA-372 CDJ-2143 NCT-57/63 NQA-4091A
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
2 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
2.
2. The setup / inspection procedure
The Setup / Inspection Procedure
The composition of this manual and the outline of an operation procedure are shown at the time of actual setup and inspection. Requirements of setup : █ = Indispensable ▲ = Required at the time of a setup change ▼ = As necessary Shipment Manual items
Contents
order
3. 4.
5.
6.
7.
Maintenance software
The outline of each function is explained according to the menu
functional list
composition of maintenance software.
Starting and quitting of
The operation method for starting and quitting of maintenance
maintenance software
software are explained.
Setup of RCU system
The operational method of a system setup for the RCU is
configuration information
explained.
Setup of DAU system
The operational method of a system setup for the DAU is
configuration information
explained.
System operation check
The operational method for checking the VDR system status is
Installation
inspection necessity
order
Necessity
-
-
-
-
1
█
1
█
2
█
2
█
3
█
3
█
5
█
4
█
6
█
5
█
4
█
-
▲
-
▼
-
▼
-
▼
-
▼
-
-
-
-
explained. Checks that the system setup is right. Checks that each unit is operating normally. Checks that data is collected. 8.
Record data check
The operational method for checking the record data of the VDR is explained. Checks record data in the HVR. Checks record data on the PC card.
9.
Setup of the factory shipping
The operational method of setup required only at the factory is explained. However, when changes have occurred differing from the contents of installation drawings at the time of shipment, resetting the change operation is required at the time of installation.
10.
Troubleshooting utility
The operational method of checking the system error is explained.
11.
Program version upgrade
The operational method for upgrading the program of the VDR is explained.
12.
Installation
The operational method for installing the maintenance software is explained.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
3 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
3.
3. Functions
Functions Menu Trees When the JCY-1700S (S-VDR) is chosen to maintain, functions with “*” mark are deleted from menu of the Maintenance Software. Because functions with “*” mark are unnecessary to maintain the JCY-1700S (S-VDR).
Pull Down Menu
Main Menu File (F)
Setup (C)
Function
Log in (L)
Displays login dialog box. Used to re-log in for changing of the login information.
Open (O)
Used to open a file.
Save (S)
Used to save a file.
Close (C)
Used to quit the maintenance software. Used to check and change the system information of the RCU.
RCU (R) DAU (D)
Used to check and change the system information of the DAU.
DAU1 (A) DAU2 (U)
FGB (F)
Used for overall maintenance (setup, check ) of the FGB.
HVR (H)
• Shipment: • Installation:
Used to set up a partition in the HVR. Used to check the LAN connection between the RCU and HVR.
Option (O)
Dry Contact (D) *
Used to setup the optional units (DSC, AIU ).
*
Analog (A)
(When the JCY-1700S is chosen to maintain, this function is deleted from the menu.)
*
Control (R)
Control (R)
Used to remotely control the VDR.
System (S)
System status (S)
Used to check operational status of VDR and give detailed information of the error status.
Monitor (M)
System Log (L)
Used to check how many times the VDR has been reset automatically.
Event Log (E)
Used to check the past event recordings of the VDR.
DAU (D)
DAU1 (A)
Used to monitor in real-time the NMEA data sentences being connected in DAU.
DAU2 (U) Audio (A)
Used to monitor in real-time the audio signal data being recorded in ARB of the RCU.
Radar (R)
Used to monitor in real-time the Radar image data beging captured on the FGB of the RCU.
Event (E)
Used to monitor in real-time the event information being detecting in the VDR.
Dry Contact (C) *
Used to monitor in real-time the dry contact data being connected in NCT-57/63. (When the JCY-1700S is chosen to maintain, this function is deleted from the menu.)
Data (D)
HVR backup (H)
Used to download the recorded data from the HVR.
Data convert (V)
Used to convert the data format recorded in JCY-1700 into playback software designed for the JCY-1000. Used to retrieve the configuration information on the PC card and create files for
Config (C)
configuring each unit. Playback (P)
Playback (P)
Used to playback of a recording data.
Setup (S)
Used to set the configuration data of playback software.
Log to TXT (T) Version up (U) View (V)
Used to convert the NMEA data recorded in the PC card into text data.
Version up (V)
Used to update the software module for the ARB (RCU), MCB (RCU), DCB (DAU).
FGB
Used to update the software module for the FGB (RCU).
(F)
A menu option to select display tool and status bars.
Tool bar (T) Status bar (S)
Window (W)
Arrange cascade (C)
A menu option to re-arrange the windows.
Arrange Horizontal (H) Arrange Vertical (L) Help (H)
A menu option to display the version information of the maintenance software
Version (V)
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
4 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
4.
4. Starting Maintenance Software
Starting the Maintenance Software 4.1
Procedures
4.1.1 Starting 1) Double-click the “Maintenance Software” icon. 2) The maintenance software will starts up, and it brings up the Log in Window.
Log in window
4.1.2
4.1.3 4.1.4
4.1.5
4.1.6
4.1.2 Enter the Name of the Person in charge, Company Name, and Password. “Register Information” 1) Registrant information Enter the information of the registrant, which will be recorded onto VDR. • Name of the person in charge • Name of the company 2) Password As you enter the password, the field appears as a string of “*”. The password for a service engineer, who is in charge of installation, is “JRCVDR” (see 4.4 for more details).
4.1.3 Selection of Ethernet Adapter The maintenance PC automatically detects the built-in Ethernet adapter. Select the Ethernet adapter to be used for maintenance. If more than one Ethernet adapter exists, select one using the pull-down button [T]. Many of recent lap top PCs are equipped with not only wired LAN but with wireless LAN as well. Such a PC has two Ethernet adapters. Select the adapter for the wired LAN.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
5 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
4. Starting Maintenance Software
4.1.4 Display of IP address of Maintenance PC Confirm that the IP address and subnet mask, which are registered in the selected Ethernet adapter, are displayed.
4.1.5 Additional of IP address for VDR The IP address for VDR maintenance is “192.168.110.200”. Add the IP address for VDR maintenance. 1) [Add IP] Click the [Add IP] button and register the IP address for the VDR. The subnet mask “255.255.255.0” is set automatically. 2) Add IP address for the VDR “192.168.110.200” is displayed as the default IP address for the VDR. * Although this IP address can be changed, there is no need to do so. Follow the procedures for quitting maintenance and delete the newly registered IP address when quitting the maintenance operation. Even though you may forget to delete it, it will be deleted when the PC is rebooted.
4.1.6 Closing Log-in Display 1) [OK] button Click the [OK] button, and the full-fledge maintenance software starts. If any error is detected in the information that has been entered in “4.1.2”, an error message appears. Re-enter the correct information. No information for the “Name of the person in charge”, or “Company name” Wrong “Password” 2) [Cancel] button Maintenance software will be started without entering registrant information and a password, the functions which can be used are restricted. Although setting functions cannot be used, displaying functions can be used. Limited functions list Menu
Pull down menu
Restriction items
Setup (C)
RCU(R)
Starting is impossible.
DAU (D)
DAU1 (A)
Starting is impossible.
DAU2 (U) FGB (F) Option (O)
Starting is impossible. Dry Contact (D)
Starting is impossible.
Analog (A) Control (R)
Control (R)
Data (D)
HVR backup (H)
Starting is impossible.
Data convert (V)
Starting is impossible.
Version up (U)
Starting is impossible.
Config (C)
Starting is impossible.
Playback (P)
Starting is impossible.
Log to TXT (T)
Starting is impossible.
Version up (V)
Starting is impossible.
FGB (F)
Starting is impossible.
4.1.7 Choosing the model to maintain The dialog for choosing the model to maintain is displayed after log-in operation. 1) Choosing the model Choose the model to maintain from JCY-1700 or JCY-1700S, and click the [OK] button
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
6 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
4. Starting Maintenance Software
2) Reception data from the RCU and DAU Reception of information required for maintenance is started after model selection, and the following dialog is displayed.
When the Maintenance software is started up without connection to the RCU, Click the [Cancel] button. ( In case of setup to the DAU and other functions)
4.2
Preparation check, HVR Setup “HVR (H)”
Check the Ethernet connection of the HVR. In the state of not being connectable with the HVR, maintenance operation is unable to continue.
1)
Click the HVR in the SETUP menu to start the HVR setup WEB.
2)
Check that the HVR setup WEB is displayed.
3) Procedure of the quitting Click the [×] button at the top right of Window.
4.3 1)
Quitting the Maintenance Software Quit all the maintenance functions that are activated.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
7 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
4. Starting Maintenance Software
If you quit the main window of the maintenance software without quitting the real-time monitor function, the VDR continues to send the recording data to the maintenance PC in real-time. Be sure to quit the real-time function before closing the main window. If you close the main window first by mistake, reboot RCU and DAU, which cancels the real-time output already ordered from the maintenance PC.
2) Click “Close” in the File menu to quit the maintenance software.
4.4
Password
There are two kinds of passwords: one is used during the inspection at the time of factory shipment, and the other for maintenance or installation on board the ship. 4.4.1 Password 1) Password for installation onboard : 2) Password for inspection at the factory :
JRCVDR *******
(It’s not written in this manual.)
4.4.2 Password for Installation 1) Maintenance functions restricted Some maintenance functions for configuring the RCU or DAU are restricted The object item in each setting screen is displayed in the state of input prohibited. Since all items are objects, below screens are not displayed. Display: “Ethernet screen” “Configuration screen” 2) VDR registrant information The altered settings of the RCU or DAU are registered as “Amendment register information.” 4.4.3 Password for Inspection 1) Maintenance functions restricted All the settings of the RCU or DAU can be changed. 2) VDR registrant information The altered settings of the RCU or DAU are registered as “Initial register information.” Some maintenance functions are restricted when the password for a service engineer is used, because there are some settings that should not be changed on site. This avoids confusion caused by seeing unnecessary displays. If you find it necessary to change some of these settings, contact the person in charge of the product at the factory. This is made for cases where the password for shop inspections is entered.
4.5
Re-Log In.
The login conditions can be changed without quitting the maintenance software. • To change the registrant information • To switch the password from maintenance to that for inspections at the factory • To change the model to maintain ( JCY-1700/JCY-1700S )
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
8 / 100
Maintenance Software Manual.doc
5. Setup of RCU
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
5.
Setup of RCU
- RCU (C) -
Set up RCU as a system design. Carry out after making LAN connection with the HVR. Setting data is not registered into VDR, even if it performs setting operation, while there is a LAN connection to the HVR.
5.1
Setting Items
The item that requires an input at the time of factory and onboard is shown in the following table. Set up all the items needed. ● R::: Input restrictions with a password: Blank = With no restriction ■ = The setup is possible only with a factory setting password. ● F::: Factory: ▼ = The setup is required. ● O::: Onboard: ▲ = The change setup may be carried out at the time of installation. No.
Screen
Category
Item
1
Identification
Ship information
Ship’s name
2
R
F
VDR information
4
Note
▼ ▼
IMO number.
3
O
Type Approval number Shipment order
■ ■
▼ ▼
Input the order of 5000 and number of equipment.
5
System
Microphone setup.
6
▼
Connecting
▼
Installation position
7
Microphone unit
8
Type Manufacturer
9
VHF setup
10
VHF transceiver
11
■ ■
▼ ▼ ▼ ▼ ▼
■
▼
Connecting Type Manufacturer
12
▼
Serial Number GPS
13
Input a Text.
Connection form
One-set connection / Two-set connection (Main / Sub)
14
Unit name
15
Type
16
Manufacturer
17
Antenna
▼ ▼ ▼
Input DGPS as text input.
▼
installation
position 18
Connection
equipment
■
▼
■
▼
▲
selection 19
Radar
Main/Sub judging signal selection by the dry contact signal.
Connection form
One-set connection / Two-set connection (Main / Sub)
▼ ▼
20
Type
21
Manufacturer
22
Serial Number
23
Record interval
■
It is not necessary to change the setting.
24
Record time adjustment
■
It is not necessary to change the setting.
25
Connection equipment
■
▼ (15seconds). (0).
▼
selection 26
Ethernet
All items
27
Configuration
System
▲
Main/Sub judging signal selection by the dry contact signal
■ All items
■
All items
■
It is not necessary to change the setting. ▼
Number change of connection of DAU.
configuration 28
A real-time monitor
29
Serial
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
A setup is required only at the time of an option system.
Reception (GPS)
9 / 100
Maintenance Software Manual.doc
■
It is not necessary to change the setting.
5. Setup of RCU
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual Communication
30 31
Transmission (alarm)
■
Communication
■
It is not necessary to change the setting. It is not necessary to change the setting.
parameter 32
Time adjustment interval
33
Time adjustment
34
ARB setup
All items
35
IT Network
All items
36
Dry contact signal
Signal selection
■ ■ ■ ■ ■
It is not necessary to change the setting. It is not necessary to change the setting. It is not necessary to change the setting. It is not necessary to change the setting. ▼
GPS / radar selection / dry contact signal input.
37
Sentence data
38
Sentence interval
39
Capsule
5.2
All items
■ ■
▼
■
▼
Dry contact signal sentence.
It is not necessary to change the setting. The type of Capsule to connect is chosen.
Procedure
1) Starting setup of the RCU Click [RCU] in the “SETUP (C)” menu.
The system configurations of RCU is displayed. File menu Tab
2)
Entering base setting values of the RCU Enter base setting values in the display of the RCU configurations. • Normally select “Receiving from VDR.”
No. Selection 1 Receiving from VDR 2 File Read
Method [Receive] button “Open” in the “File” menu
Purpose Receives the setting values of RCU Reads the saved setting file in the maintenance PC.
Unless the standard setting values are entered, the [Set], [All set], [Reboot] buttons are not available.
3) Selecting tab Click the tab of the items which you wish to set.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
10 / 100
Maintenance Software Manual.doc
5. Setup of RCU
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
4)
Editing Change setting values.
5) Setting Click the [SET] button to transmit the updated setting values to the RCU. 6)
Altering the configuration display When editing in more than one display, repeat the above Steps (3 through 5).
7)
Quitting the setting Be sure to click the [Reboot] button when finished setting the system configurations.
8)
Quitting setup of RCU Click the [Close] button to quit the operation.
5.3
Common Buttons
5.3.1
5.3.2 5.3.3 5.3.4
5.3.7 5.3.5 5.3.6
5.3.1 [ Receive ] Clicking this button, the maintenance software receives configuration data from the RCU.
5.3.2 [ Set ] Clicking this button transmits the setting values on this screen to the RCU. [ SET ] button registers only the data on the screen currently displayed onto the RCU. If editing is completed, click the [SET] button for every screen and be sure it transmits.
5.3.3 [ Reboot ] Be sure to click this button after completing editing or registering the setting values. The updated setting values become effective only after the [Reboot] button is clicked. • Clicking on this button saves the setting values onto RCU as well as the HVR. • Clicking on this button makes RCU run on the updated setting values by rebooting it. An “Initial error” occurs if you start the RCU by using the main power SW without clicking the [Reboot] button. When the “Initial error” appears, the operation with [FUNC+RESTART] of the clause 10.1.2 can reset the error. ( Button operation on the internal operation panel of RCU is also possible. )
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
11 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
5. Setup of RCU
5.3.4 [ ALL set ] Clicking this button transmits the setting values of all screens to the RCU.
5.3.5 [ Default ] Initializes the setting value of the screen currently displayed. 5.3.6 [ All Default ] Initializes the setting value of all screens. [ Default ] and [ All Default ] button appears, only when it’s logged in with the password for inspections. These are used when creating a system configuration information file in the state where it does not connect with RCU.
5.3.7 [ Close ] This button terminates the setting of the RCU configurations.
5.3.8 File Operation The setting data can be saved in the file and the saved file can be opened.
1) Save Click “Save” in the File menu. The dialog for inputting the name of saved file will be displayed. 2)
Open Click “Open” in the File menu. The dialog for specifying an object file will be displayed.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
12 / 100
Maintenance Software Manual.doc
5. Setup of RCU
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
5.4
Identification
How to set the identification information of the VDR (RCU) are explained in this section. ( ■ ) mark is placed in the field to indicate an invalid input when logged in with the password for installation.
5.4.2 ( ■ )
5.4.1
5.4.3
5.4.4
5.4.1 Ship's identification Enter the ship’s identification information. 1) Ship’s name Enter the ship’s name. 2) IMO ID number. Enter the IMO ID number.
5.4.2 VDR identification Enter the VDR information. 1) Approval No. ( ■ ) Enter the type approval number of the ship’s class. 2) JRC shipping order ( ■ ) Enter the shipping order number and the serial number of the RCU.
5.4.3 VDR Software version The software version number of JCY-1700 system and each unit are displayed.
5.4.4 Register information Registrant information is displayed, and entered on the Log in screen. 1) Initial The name of the person in charge, company name, and the date & time of registration (UTC) are automatically registered if you login using the password used for inspections at the factory when updating the RCU configurations. 2) Amendment The name of the person in charge, company name, and the date & time of registration (UTC) are automatically registered if you login using the password used for maintenance on site when updating the RCU configurations. When you login and click the [Receive] button, the information registered on the VDR is displayed. Registrant information is updated when [Set] button is clicked on any screen.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
13 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
5.5
5. Setup of RCU
System
How to set the VDR (RCU) configurations are explained in this section. ( ■ ) mark is placed in the field to indicate an invalid input when logged in with the password for installation.
5.5.1 5.5.1.1
( ■ ) 5.5.1.2
5.5.1.3 ( ■ )
5.5.2 5.5.2.2 5.5.2.1
5.5.3
5.5.3.1 ( ■ )
5.5.3.2
5.5.3.3 5.5.3.4
( ■ ) 5.5.3.5 5.5.4.1 ( ■ )
5.5.4
5.5.4.3 ( ■ ) 5.5.4.4 ( ■ )
5.5.4.2
5.5.4.5
5.5.4.6 ( ■ )
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
14 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
5. Setup of RCU
5.5.1 Microphone How to configure microphone ports are explained. 5.5.1.1 Setting the microphone ports (CH1 ~ Ch9) Set the each connection port that is connected to microphone units (the maximum number of microphone units are 9). 1) Connection status: • Indoor : Select this if an indoor microphone (NVT-156) is connected to the port. • Waterproof : Select this if a waterproof microphone (NVT-157) is connected to the port. • Not-connected : Select this if a microphone is not connected to the port. (default) 2)
Installed: Type in the position of the microphone using less than 31 characters. The entry field of “installed” becomes “unable” if “Not-connect” is selected above.
5.5.1.2 Setting the Microphone unit ( ■ ) Enter the information of the microphone unit. 1) Model: Enter the model name of the microphone unit. Normally enter the model name of the microphone for JCY-1700 as: “NVT-156.” 2) Manufacturer: Enter the name of the manufacturer. Normally enter “JRC”.
5.5.1.3 Setting the Waterproof Microphone unit ( ■ ) Enter the information on the waterproof microphone unit. 1) Model: Enter the model name of the microphone unit. Normally enter the model name of the waterproof microphone for JCY-1700 as: “NVT-157.” 2) Manufacturer: Enter the name of the manufacturer. Normally enter “JRC”.
5.5.2 VHF transceiver How to set the connection of the VHF transceiver is explained. 5.5.2.1 Setting the connection of the VHF transceiver Set each connection port connected to the VHF transceivers (the maximum number of three (3) VHF transceivers). 1) Connection status: • Connect : Select this if a VHF transceiver is connected to the port. • Not-connect: Select this if a VHF transceiver is not connected to the port (default). 5.5.2.2 Setting VHF transceiver Enter the information of the VHF transceiver. 1) Model: Enter the model name of the VHF transceiver. 2) Manufacturer: Enter the name of the manufacturer. 3) Serial No.: Enter the serial number of the VHF transceiver. The entry fields in “VHF transceiver unit” becomes “unable” if “Not-connect” is selected.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
15 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
5. Setup of RCU
5.5.3 GPS for Date, Time and Ship’s position How to set the GPS is explained. 5.5.3.1 Setting the connection of the GPS ( ■ ) Select the connection configuration of the GPS. • Main GPS only: Select this if only one GPS is connected. • Main/Sub GPS: Select this if two GPS’s are connected via a selection switch.
DAU
SWITCH Main GPS
NMEA Serial Input Port
Sub GPS
RCU Input Port
OPEN/CLOSE Dry Contact
5.5.3.2 Setting the GPS Enter the information of the GPS 1) Equipment Enter the type of the equipment. Normally enter GPS or DGPS. 2) Model Enter the model name of the GPS. 3) Manufacturer Enter the name of manufacturer of the GPS. The VDR standard is required to record the type of equipment that is entered for ship’s position and time correction. Therefore the equipment type name, DGPS, is entered here, too.
5.5.3.3 Installed antenna position Enter the position of the antenna for the GPS. Enter the distances in meter from the Bow, Stern, Port and Starboard. 5.5.3.4 Recording start time The RCU automatically records the start time of operation in order to identify which ship’s position, date and time data is received from the two GPS’s (main or sub). Start time to be used is updated to the change timing of the selected signal that is input from a GPS selection switch . → The start time to use of selected GPS equipment is updated. Para. 5.5.3.2 through 5.5.3.4 is for both the main and sub GPS’s. Only when “Main/Sub GPS” is selected in para. 5.5.3.1, does the entry field of the sub GPS become “able.” → Enter the entry field of the sub GPS.
5.5.3.5 Main/Sub selection by dry contact ( ■ ) You can set which dry contact signal corresponding to which GPS. • Open for Main; Close for Sub: the state of the dry contact is “open” when the main GPS is selected. • Open for Sub; Close for Main: the state of the dry contact is “open” when the Sub GPS is selected. If the GPS selection port is not connected, the state of the dry contact signal is “Open.” By default, the state of dry contact signal “Open” indicates that the Main GPS is selected.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
16 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
5. Setup of RCU
5.5.4 RADAR Entering Radar information. 5.5.4.1 Setting the connection for RADAR ( ■ ) Select the connection configuration of the RADAR. y Main RADAR only: Select this when only one RADAR is connected to RCU. y Main/Sub RADAR: Select this when two RADAR are connected to RCU via selection switch.
SWITCH
RCU
Main Radar
RGB FGB
Sub Radar Input Port OPEN/CLOSE Dry Contact Signals
5.5.4.2 Setting the Radar Enter the information of the RADAR device. 1) Model Enter the type name of the RADAR device. 2) Manufacturer Enter the manufacturer’s name of the RADAR device. 3) Serial No. Enter the serial number of the RADAR device. 5.5.4.3 Recording interval ( ■ ) The recording interval of the RADAR image can be set in milliseconds. By default, it is set as 15000ms, and there is no need to change it. (By VDR standard, it is 15 seconds). 5.5.4.4 Adjusting ( ■ ) The correction time value for adjusting the recording time of RADAR image can be set in milliseconds. By default, it is set as 0ms, and there is no need to change it. The recording time is not equal to the time which captures the RADAR image. There is a gap between the two timings. The correction time value is used to narrow this gap. But actually, the gap is negligible, and therefore there is no need to change this setting value.
5.5.4.5 Recording start time The RCU automatically records the start time of operation in order to identify which of the two RADAR devices (main or sub) is transmitting data. Start time to use is updated to the change timing of the selection signal that is input from a RADAR selection switch. Para. 5.5.4.2 through 5.5.4.4 is for both the main and sub RADAR devices. Only when “Main/Sub RADAR” is selected in para. 5.5.4.1, does the entry field of the sub RADAR become “able.” → Enter the entry field of the sub RADAR.
5.5.4.6 Main/Sub selection by dry contact ( ■ ) You can set which dry contact signal corresponding to which RADAR (main/sub). • Open for Main; Close for Sub: the state of the dry contact is “open” when the main RADAR is selected. • Open for Sub; Close for Main: the state of the dry contact is “open” when the Sub RADAR is selected. If RADAR selection port is not connected, the state of the dry contact signal is “Open. “ By default, the state of dry contact signal “Open” indicates that the Main RADAR is selected.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
17 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
5.6
5. Setup of RCU
Ethernet How to set the parameters of Ethernet network connected to the RCU is explained. If the password for installation is used to login, this screen does not appear. Therefore, the ( ■ ) marks are placed in all fields. The setting change for “Ethernet” is required only when building an option system. Do not change the setting when the JCY-1700 is shipped with standard composition. If the IP address is forgotten it will to be impossible to use the maintenance by the LAN connection.
( ■ ) 5.6.1 5.6.3
(■)
5.6.6
(■)
( ■ ) 5.6.2 ( ■ ) 5.6.4
( ■ ) 5.6.5
( ■ ) 5.6.7 ( ■ ) 5.6.8
5.6.1 MAC address ( ■ ) The MAC address is displayed. The MAC address is a unique address assigned to Ethernet communication adapter. It is registered at the factory and should never be changed.
5.6.2 System ( ■ ) Set the common parameters of the Ethernet. 1) Subnet mask 255.255.255.0 2) Default gateway 192.168.110.100 This is needed when UDP signals from VDR are transmitted to another LAN network via a router. 5.6.3 Capsule ( ■ ) Set information of HVR. 1) IP address 192.168.110.2 2) Port No. 5000 5.6.4 RCU ( ■ ) Set information of RCU. 1) IP address 192.168.110.3 2) Port No. y For DAU: y For Option/Maintenance PC:
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
5000 6000
18 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual y
For receiving of time correction signals:
5. Setup of RCU
7000
5.6.5 DAU ( ■ ) Set parameter for Ethernet of the DAU. 1) Standard IP address 192.168.110.100 2) Port No. y For RCU: 5000 The actual IP addresses of DAU1 and DAU2 are obtained by adding the unit number to the standard IP address as below. y DAU1: 192.168.110.101 y DAU2: 192.168.110.102
5.6.6 FGB ( ■ ) Set parameter the Ethernet of the FGB. 1) Standard IP address 192.168.110.150 2) Port No. y For browser: 80 The actual IP address of the FGB is 192.168.110.151.
5.6.7 Option/Maintenance PC ( ■ ) Set the IP address of the PC that is connected to the VDR. 1) Option PC IP address of the PC as a real-time monitor (option) 192.168.110.200 2) Maintenance PC IP address of the maintenance PC 192.168.110.200 3) Port No. The port number to which real-time monitor signals are transmitted y Audio data: 50002 y Event data: 50003 y Reference (image data are transmitted to FGB): 50001 Notice that when an optional PC is not used, the IP address of the maintenance PC (192.168.110.200) is used as the default setting. When any optional system is to be setup, its IP address needs to be renewed.
The IP address indicates where real-time signals (UDP/IP) are transmitted.
5.6.8 IT Network ( ■ ) Set the connection of the FTP to the maintenance PC server on the ship (under development). 1) IP address 192.168.110.160 2) FTP Port No. 21 3) User name 4) Password Since it has only registered as provisional specification, it is not the last specification. In using it, it sets up at the time of factory shipments.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
19 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
5.7
5. Setup of RCU
Configuration How to set operation parameters of the RCU is explained. This screen is not displayed when the password for maintenance is used to login. Therefore, the ( ■ ) marks are placed in all fields. Basically, there is no need to change these settings. However, it is needed when shipping the following system. ・ Two-set connection of DAU ・ When the dry contact port (3 inputs) is used ・ Option system setup
( ■ ) 5.7.1
5.7.2
(■)
5.7.4
(■)
( ■ ) 5.7.3
( ■ ) 5.7.5
( ■ ) 5.7.6
( ■ ) 5.7.7
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
20 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
5. Setup of RCU
5.7.1 System Construction ( ■ ) Set the “able / unable” of the system components in the VDR. 1) Standard Components The following components are standard and marked with a [9]. y Capsule y DAU1 y FGB y ARB 2) DAU2 When DAU2 is added to the system, mark with a [9]. 3) Capsule type As the capsule for JCY-1700 is a “NDH-288B”, “288B” is set as the default setting value. An option “288A” is for the old type of capsule”NDH-288A”. The difference between “288A” and “288B” is in their memory capacities. The setting needs to be changed if it is connected to NDH-288A. If “288A” is selected for JCY-1700, event is not recorded in the capsule.
5.7.2 Real Time Monitor ( ■ ) To enable the output of real-time signal data, mark with a [9]. Set up when you confirm a real-time data output as a system option function. Effective (mark with a [9]) / non-effect is set up for every signal to output. About Real Time Monitor as the option system If the output is confirmed, the data can be output all the time, and the output can be continued even after the power supply is restarted. The data can be output to the IP address of the Option PC. - Reference About Real Time Monitor as the maintenance function The data output is terminated when the power supply is restart. The data can be output to the IP address of the Maintenance PC.
5.7.3 RCU Serial Port ( ■ ) The setting of the RS422 serial port in the RCU can be updated. However, there is no need to change its setting values under the present system configuration. The serial port is used for the following purposes. y Receipt: ZDA signals from GPS enable the time correction of RCU on its own. → Usually signals from DAU are used for is purpose. y Transmission: Error sentences of VDR are transmitted to other devices
5.7.4 Time correction by GPS ( ■ ) It is a parameter setup in the case of performing time correction with the ZDA sentence which RCU receives from a serial port. Since it is not used in the standard system, it is not necessary to make a setting change. 1) Time correction interval The time correction interval of the RCU can be set up. 2)
Adjusting Time correction can be fine tuned in ms. It is the specification of a design stage and does not adopt as a product. The usual operation is as follows. The RCU is performing time correction by receiving for time correction data from DAU. The LAN circuit transmits the data for time correction.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
21 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
5. Setup of RCU
5.7.5 ARB ( ■ ) The operation parameters of the ARB can be updated. However, there is no need to do so. 5.7.6 IT Network ( ■ ) Set up of I/F specification for the onboard failure diagnostic system is under development. Since it has only registered as a provisional specification, it is not the last specification. In using it, it sets up at the time of factory shipments.
5.7.7 Dry Contact ( ■ ) For Dry Contact signals, select the use of the input ports 1-3. 1) Ports 1-3 For each port, select the use from the following options. y Input port of switch signals when two GPS’s or two RADAR devices are used. y Input port of general dry contact signals →
If the number of dry contact inputs are 3 or less, optional unit for dry contact signals (i.e., digital signal converter NCT-57/63) is not needed. Port 1: Port 2: Port 3:
Select either “GPS select (default)” or “DRY contact”. Select either “RADAR select (default)” or “DRY contact”. Select either “SPARE select (default)” or “DRY contact”.
2) Header Enter the header of output data sentences when the port is used as an input port of dry contact signals. 3)
Open data/close data Enter the message of output data sentences when the port is used as an input port of dry contact signals.
4)
Sentence cycle Set the output conditions when the port is used as an input port of dry contact signals. Set the time interval in the second unit at which data are transmitted even though there is no change in the incoming dry contact signals. Data sentence output trigger y At the time when the condition changes y At the specified time interval when no conditional change is detected The Dry Contact updating of the settings is only viable when the Dry Contact is selected.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
22 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
5.8
5. Setup of RCU
Capsule
Select the model of capsule connected to theVDR/S-VDR.
This function is added with software update (Ver. 2.0.0) of the RCU. The Maintenance software does not display this screen in case of maintaining to the RCU installed old software.
This screen is not displayed when the password for maintenance is entered to login.
It is registered at the factory and should never be changed. So the details of setting on this screen are omitted.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
23 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
This page is intentionally left blank
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
24 / 100
Maintenance Software Manual.doc
5. Setup of RCU
6.
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
6.
Setup of DAU
Setup of DAU
- DAU (D) -
Set up DAU as a system design Carry out after making LAN connection with HVR. Setting data is not registered into VDR, even if it performs the setting operation, while the LAN connection with the HVR has been an error.
6.1
Setting Item
The item that requires an input at the time of factory and onboard is shown in the following table. Set up all the items needed. When the JCY-1700S (S-VDR) is chosen to maintain, screens with “*” mark are deleted from DAU setup. Because functions on screens with “*” mark are unnecessary to maintain the JCY-1700S (S-VDR).
● R::: Input restrictions with a password:
Blank = With no restriction ■ = The setup is possible only with a factory setting password. ▼ = The setup is required. ▲ = The change setup may be carried out at the time of installation.
● F::: Factory: ● O::: Onboard:
R
No.
Screen
Category
Item
1
Identification
VDR information
Shipment order
■
F
O
▼
Note Input the manufacture order and serial number of DAU.
2
System
Time adjustment
Host DAU
4
Adjustment
5 6
■ ■ ■ ■
Interval
3
Input CH Serial
Channel
7
Channel Effective/invalid
8
Receiving
Signal type
9
conditions
Communication mode
10
Sentence form
11
Sentence length
12
Receiving interval
13
Record sentence
14
ID The contents of a signal
15
Connection
Unit name
16
equipment
Type
17
Manufacturer
18 19
▼ ▼ ▼ ▼ ▼ ▼ ▼ ▼ ▼ ▼ ▼ ▼ ▼ ▼
20
Synchronization connection
NMEA / A/D / DRY-CNT / NAV-IF Baud rate, Data, STOP bit, Parity A header, a delimiter, a checksum
▲ ▲
Filter setup
▼
Serial number NAV-I/F *
GPS connecting CH
Effective/invalid Rudder / wind direction
▼ ▼
Selection 21
Unit name
22
Type
23
Manufacturer
24
Serial number
25
Rudder setup
26
▼ ▼ ▼ ▼
Ratio Conversion condition
▼ ▲ ▼
Needs to be set up at the time of connection.
▲ ▼
Needs to be set up at the time of connection.
setup 27
Wind direction
28
Direction setup Conversion
condition
▼
setup 29
Analog connection
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
All items
Fundamentally, it is not used.
25 / 100
Maintenance Software Manual.doc
6.
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual 30
Contact *
31
Analog *
Analog conversion
Setup of DAU
File setup
▼
▲
Registration of a NCT-57/63 setting file.
A coefficient setup of a
▼
▼
Needs to be set up at the time of connection.
conversion formula Effective/invalid
▼
33
Data unit
34
The contents of a signal
35
Unit name
36
Type
▼ ▼ ▼ ▼ ▼
32
Connection CH
37
Manufacturer
38
Serial number
39
Ethernet
All items
40
Configuration
Real-time monitor
▲ ▲
▼ ■
All CH
■
It is not necessary to change the setting. ▼
A setup is required only at the time of an option system.
6.2
Procedure
1) Starting up Select [DAU] in the SETUP menu, and then select either DAU1 or DAU2.
2)
6.3
Procedure Basically the same as what is instructed in “5.2 Procedures” of “5. Setup of RCU”. Refer to “5.2 Procedure”.
Common Buttons
Basically the same as what is instructed in para.“5.3 Common Buttons” of “5. Setup of RCU”. Refer to para.“5.3 Common Buttons”. There are some special conditions for DAU as follow. Unlike other settings, once the setting of “Serial” of DAU is updated, it becomes effective when the [SET] button is clicked. The updating of the other settings, however, becomes effective only after the [Reboot] button is clicked. This is because of understanding that once the setting of the filter of NMEA sentence is updated, it should be made effective as soon as possible.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
26 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
6.4
6.
Setup of DAU
Identification How to set the ID information of DAU is explained in this section. ( ■ ) mark is used as a default of an input when logged in with the password for installation.
6.4.1 ( ■ ) 6.4.2
6.4.3
6.4.1 DAU-Software version The software version of the DCB (DAU) is displayed.
6.4.2 VDR identification ( ■ ) Enter the ID information of the VDR and the serial number of the DAU. 1) JRC shipping order Enter the manufacture order and the serial number of the DAU.
6.4.3 Register information The registrant information, which is entered at the time of login, is displayed. 1) Initial The name of the person in charge, company name, and the date & time of registration (UTC) are automatically registered if you login using the password used for inspections at the factory when update the DAU configurations. 2)
Amendment The name of the person in charge, company name, and the date & time of registration (UTC) are automatically registered if you login using the password used for maintenance on site when update the DAU configurations.
When you login and click the [Receive] button, the information registered on the VDR is displayed. Select this tab and click either the [Set] button or the [Reboot] button, only then is the registrant information is updated.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
27 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
6.5
6.
Setup of DAU
System How to set the VDR (DAU) configurations is explained here. ( ■ ) mark used as a default of an input when logged in with the password for installation.
( ■ ) 6.5.1
6.5.1 Time correction by GPS Set the parameters to correct the time with ZDA data sentences from GPS. 1)
Correction interval ( ■ ) The interval of time at which the time of the VDR is corrected automatically can be set. By default, it is set as 12 hours, and it is unnecessary to change this setting. The timing of time correction: • At the time of starting the VDR: When the DAU to which the GPS is connected starts. • At every 12 hours: The time is corrected at 0:00 and 12:00 everyday. To be exact, it is done 30 seconds later.
2)
Adjusting ( ■ ) The correct time value can be set to adjust in milliseconds. By default, it is set as 0ms, and there is no need to change it. The correct time value is intended for use in the cancellation of the time lag that may be caused by the delay of time correction. However, the time lag is negligible and therefore there is no need to change this setting.
3) Host unit ( ■ ) Set the DAU connected to the GPS. Select DAU1 or DAU2 from the pull-down menu. → By default, it is DAU1 and there is no need to change this. 4)
Input port ( ■ ) Set the CH number for the serial port connected to GPS. How time correction is done: DAU specified as “Host unit” receives ZDA data sentences through the specified channel, and transmit to other equipment the time correction information via LAN. Confirmation of the time correction At the startup of DAU that is connected to GPS, RCU and DAU correct time automatically. The event of time correction can be monitored through the real-time event monitoring system.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
28 / 100
Maintenance Software Manual.doc
6.
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
6.6
Setup of DAU
Serial How to set the parameters of the serial port is explained.
6.6.2 6.6.1
6.6.6
6.6.3 6.6.3.1
6.6.3.2
6.6.3.3
6.6.3.4
6.6.4
6.6.5
6.6.1 Channel Select the DAU serial port channel from the pull-down menu (CH01-CH16).
6.6.2 Enable For each serial port of the specified CH, select “Enable” or “Disable”. Mark with a [9] if a sensor is connected to the designated CH. y Enable: [9] (checked) y Disable: [ ] (unchecked) Once the serial port is set to “enable” [9], all the entry fields of the display become “enable.”
6.6.3 Serial port setting Set the receiving condition of serial ports. 6.6.3.1 Type Select the type of receiving sentences. No.
Type
Connector
Selectable CH
Remark
1
NMEA
General sensors
CH01-CH16
NMEA
2
NSK
NSK unit (option)
CH01-CH16
NCT-27B
3
NAV-I/F
NAV-I/F unit (option)
CH12
NCT-52A
4
DRY-CNT
Digital signal converter unit (option)
CH13、CH14
NCT-57/NCT-63
5
A/D
Equipment with built-in DAU, Analog input unit
CH15、CH16
NCT-58 (A/D built-in) NQA-4091A
6 7
DCNT+A/D
Equipment with built-in DSC
*1 *2
(Addition of the optional A/D converter board)
AIS *1
AIS unit
CH13、CH14
NCT-57/NCT-63 (A/D built-in)
CH01-CH16
NMEA
*1 These types will be selectable with the latest software (Ver. 2.0.0) update of the DAU. *2 Select the “DCNT+A/D” when the optional A/D converter board is built in the DSC.
Channels that an option unit can be connected to are limited. For only these channels, the sentence type of option unit can be selected.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
29 / 100
Maintenance Software Manual.doc
6.
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
Setup of DAU
6.6.3.2 Communication parameters Set the communication parameter. y Communication speed y Data bit length y Stop bit length y Parity bit y Check sum enable/disable
Once the type is selected, this parameter is automatically set by default. There is no need to change this value.
6.6.3.3 Sentence format Set the sentence format. y Header character y Delimiter code y Maximum sentence length y Maximum time interval of receiving Once the type is selected, this parameter is automatically set by default. There is no need to change this value. Only a maximum time interval of receiving needs to be changed by connection equipment. 1)
Header Enter the header character. “$” is entered in case of connecting to the general sensor units. In case of connecting to the AIS, enter “!” as the header character. (DAU software: Ver. 2.0.0 or later) When “!” is entered, the DAU receives the NMEA sentences with “$” and “!” as header. 2) Delimiter Enter the delimiter in the form of codes. The delimiter is expressed as codes not as characters. ““ can be codified as “OD OA”. 3)
Maximum sentence length Set the maximum length of the data sentence. Any data sentence of which length exceeds this maximum sentence length is rejected and an error is reported. The maximum length of the NMEA sentence is 82Byte.
4)
Maximum time interval of receiving Set the maximum time interval of receiving. If the time taken to receive a data sentence exceeds this maximum time interval, the sentence is rejected and an error is reported. For example, suppose ZDA, DTM, and GGA are set to be received. If the time taken to receive all ZDA, DTM and GGA exceeds the maximum time interval, all the information is rejected and an error is reported.
6.6.4 Recording data Whether a sentence is recorded in the VDR is determined by the sentence ID. Any sentence of which ID is different from the specified sentence ID is discarded and is not recorded in the VDR. 1)
Sentence ID Set the sentence ID for filtering the sentence to be recorded. y Type in 7 characters maximum, starting from the next to the header characters. y Enter all the sentence IDs of the sentences to be recorded. A maximum of 12 IDs can be registered. In case of NMEA sentence: y y y y y
The talker ID (2 characters) can be entered along with the sentence ID (3 characters). An uncertain character also can be entered using “?”. Enter as many characters as you like (up to 7 characters). At least, include the sentence ID (3 characters). Examples: setting sentence ID for filtering ZDA sentences of GPS. ( all OK ) ▫ GPZDA ▫ GPZDA?? ▫ ??ZDA ▫ ??ZDA??
As for JCY-1000, sentence ID are 3 characters and different in the way it is set.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
30 / 100
Maintenance Software Manual.doc
→Input only sentence ID (3 characters ).
6.
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
Setup of DAU
In case of option unit sentence: y AIU (NQA-4091A) : VRXDR y DSC (NCT-57/63) : ? ( Since all sentences are recorded, "?" is set up as a wildcard. )
2)
Contents Select the type of information obtained from the filtered sentences. Recording items
No.
Character string displayed
Date and Time
01
Date and Time
001
ZDA
Ship's position
02
Ship's position
002
GGA
003
DTM
Ground/Water speed
04
Ground/Water speed
004
VBW
Ship's heading
05
Ship's heading
005
HDT
06
Water speed and heading
027
VHW
Depth
07
Depth
007
DPT
Rudder order and response
08
Rudder order ,manual
030
HTD
09
Rudder response ,manual
009
RSA
10
Rudder order ,automatic
011
HTC
11
Rudder response ,automatic
010
HTD
03
Local geodetic datum
(DTM)
ID
NMEA
HDG
M/E RPM set order and response
12
M/E RPM set order
13
M/E RPM actual response
14
Main alarms
( CPP order ) ( CPP order )
Telegraph order position
012
PRC
013
RPM
021
ETL
15
Thruster order
018
TRC
16
Thruster response
019
TRD
17
Main alarms (ALA)
008
ALA ALR
and
18
Alarm information (ALR)
038
alarm of each units
19
Fire detection
017
FIR
( AIS and so on )
20
Water level detection
020
WAT
Door status
21
Door status
032
DOR
Hull door status
22
Hull door status
014
DOR
Fire door status
23
Fire door status
015
DOR
Watertight door status
24
Watertight door status
016
DOR
Accelerations and Hull stress
25
Accelerations
022
26
Hull stress
023
Wind speed and direction
024
MWV
026
VRXDR
Wind speed and direction
27
Analog option
28
A/D convert data-1
(Option unit)
29
A/D convert data-2
(Option unit)
NAV-I/F option
30
NAV-I/F data
Dry contact option
31
Dry Contact data-1
(Option unit)
32
Dry Contact data-2
(Option unit)
Radar AIS
Navigation
33
(Option unit)
HSS
033
VRXDR
028
ANADATA
029
*****
034
*****
Radar target
025
TTM
34
AIS VDO data
035
VDO
35
AIS VDM data
036
VDM
36
Status information (TXT)
037
TXT HSC
37
Heading steering command (CTS)
039
38
Rate of turn
040
ROT
Water current
39
Water current
041
VDR
Others
40
Other
999
This setting does not affect the overall operation of the VDR. However, be sure to set this value because this is going to be important information when the recording data is played back.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
31 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual 3)
6.
Setup of DAU
Watch (TYPE: NMEA, AIS, NSK) The NMEA sentence to record and the NMEA sentence to watch can be set up individually. Set the Watch function of each NMEA sentences to enable or disable. The VDR will generate the error alarm when the NMEA sentences set as “Enable” are not received within interval time. The VDR will not generate the error alarm when the NMEA sentences set as “Disable” are not received within interval time. y Enable: [9] (checked) y Disable: [ ] (unchecked) When the NMEA sentence ID is registered, checks will be entered by a default. y
In case of set to disable Setting as “Disable” is effective when a sensor unit do not transmit some NMEA sentences periodically. Set as “Enable” to only the NMEA sentence received periodically.
This function is added with software update (Ver. 2.0.0) of the DAU. The Maintenance software does not display this function in case of maintaining to the DAU installed old software.
When no NMEA sentences are received periodically. When all NMEA sentences are set as “Disable”, the VDR will operate as follows: • The VDR generates the error alarm of no NMEA sentences at the DAU start up. ( NG lamp lights up) •The VDR clears the error alarm at receiving a NMEA sentences. (OK lamp lights up, NG lamp puts out the light) • The VDR does not generate the error alarm again even if no NMEA sentences receve. (OK lamp continues lighting up) This setting as “Disable” is recommended if a user can output a NMEA sentence easily. Explain how to clear an error by outputting a NMEA sentence Difference from the OFF of DIP-SW When the DIP-SW is OFF, the VDR forvids to generate error alarm therefore the VDR will operate as follows: • The VDR does not generate the error alarm of no NMEA sentences at the DAU start up. ( OK and NG lamp continue off) •The VDR turn on an OK lamp at receiving a NMEA sentences. (OK lamp lights up) • The VDR turn off an OK lamp at passed watching period without NMEA sentences. (OK lamp puts out the light)
6.6.5 Setting connecting equipment Enter the information of the connecting equipment. 1) Equipment Enter the name of the connecting equipment. (GPS, Echo sounder, etc.) 2) Model Enter the model name of the connecting equipment. 3) Manufacturer Enter the name of the manufacturer of the connecting equipment. 4) Serial No. Enter the serial number of the connecting equipment.
6.6.6 List display The selection of the enable/disable of 16CH total and the contents of the setting of sentence ID can be displayed in the list. Click [List view]button.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
32 / 100
Maintenance Software Manual.doc
6.
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
6.6.6.1
1)
6.6.6.2
6.6.6.1
6.6.6.1 List display end 1) Close Can returns to “Serial” setting menu after the list display screen is finished. Click [Close] button. 2) Setup Can return to the setting screen of CH specified with the Setup selection button. Click [Setup] circle button.
6.6.6.2 File saving The list currently displayed can be saved as a “CSV file”. Click [Save file] button. The dialog for setting up a saving file is displayed.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
33 / 100
Maintenance Software Manual.doc
2)
Setup of DAU
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
6.7
6.
Setup of DAU
NAV- Interface
(When the JCY-1700S is chosen to maintain, this screen does not be displayed.) How to set the parameters of NAV-I/F is explained. Set up in order to record the right data even this setting does not affect the overall operation of the VDR. The setting values need to be set to convert the output of the NAV-I/F into signals concerning the rudder angle and the wind direction.
6.7.1
6.7.4 6.7.3
6.7.2
6.7.4
6.7.5
6.7.4
6.7.1 Enable Mark with a [9] if a sensor is connected to the specified CH. y Enable: [9] (checked) y Disable: [ ] (unchecked)
6.7.2 Synchronization signal Check signal type to connect. Select one from “Rudder” or “Wild direction”. “Rudder” can be select in both CH1 and CH2 . However, since NCT-52A does not correspond to a twin rudder, even if it sets up, it does not operate.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
34 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
6.
Setup of DAU
6.7.3 Connection equipment information Enter the Connection equipment information. 1) Equipment Enter the type of the equipment. 2) Model Enter the model name of the connection equipment. 3) Manufacturer Enter the name of the manufacturer. 4) Serial No. Enter the serial number of the connection equipment.
6.7.4 Setup of the conversion coefficient of the rudder angle. Set up the conversion coefficient of the rudder angle in the NAV-I/F unit as following procedure. -- procedure --1 Select the setting CH. -2 Setup ratio of the connect equipment. -3 Click [NAV-I/F connect] button. -4 Control the actual rudder, so that the rudder angle value is set to "00.0." -5 Click [Initializing] button. -6 Wait for 5 seconds until initial processing of a NAV-I/F unit (NCT-52A) is completed. -7 Click [Keep rudder=0.0 and press]button. -8 The rudder angle value displayed on the "Check value" field is recorded on VDR. Check whether a display value on the “Check value” is right. -9 Redo from procedure “-5” when it is not right. -10 Click [Read]button, when checking the setting data to the NAV-I/F unit (NCT-52A). -11 Click [NAV-I/F disconnect] button to quit when the setup is correctly set. When an operation start is carried out with the [NAV-I/F connect] button, finally, click the [NAV-I/F disconnect] button to quit surely. The button ([Set] etc) of the setting relation on the right side of a screen does not become effective if the [NAV-I/F disconnect] button is not clicked to quit. Restart the DAU when the quitting operation has not made. The data of NAV-I/F is not recorded to VDR if the quitting operation is not made.
6.7.5 Setup of the conversion coefficient of the wind direction. Set up conversion coefficient of the wind direction in the NAV-I/F unit as following procedure. -- procedure --1 Select the setting CH. -2 Set up the wind direction setting. -3 Click [NAV-I/F connect]button. -4 Control the anemoscope to stabilize the value of the wind direction. -5 Click [Initializing] button. -6 Wait for 5 seconds until initial processing of a NAV-I/F unit (NCT-52A) is completed. -7 Enter the value of the wind direction which is displayed on the anemoscope. -8 Click[SET]button. -9 The value of the wind direction displayed on "Check value" field is recorded on VDR. Check whether a display value on the “Check value” is right. -10 Redo from procedure “-5 “ when it is not right. -11 Click [Read]button, when checking the setting data to the NAV-I/F unit (NCT-52A). -12 Click [NAV-I/F disconnect] button to quit when the setup is correctly set. Since the analog signal input channels of CH3 and CH4 are not used, explanation is omitted.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
35 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
6.8
6.
Setup of DAU
Contact
(When the JCY-1700S is chosen to maintain, this screen does not be displayed.) How to input the information for managing the dry contact signal is explained. Although this setup does not affect operation of the VDR, please be sure to set it up in order to record the right data. These setup value are used with playback software.
6.8.1
6.8.2
6.8.3
6.8.1 Select CH Select the Serial CH (connect the DSC) of the DAU. Select CH13 and CH14 whichever is connected to the DSC. 6.8.2 File read Click [File read] button to read the setting file of the DSC (NCT-57/63). The setting data will be displayed on the item “Sentence ID” if it can read correctly. "TYPE" setup (Setup at serial menu) of Selection CH Unless it is "DRY-CNT", the [File read] button does not become effective. If [File read] button is not becoming effective, check a setup of a "Serial screen."
6.8.3 Sentence ID Talker ID and Sentence ID which DSC generate sentence are displayed. 1) DRY Contact No. select The DSC can input 128 signals the maximum. They are four division in a total of 128 signal(32 signals each). ● 1--32 / ● 33--64 / ● 65--96 / ● 97--128 CH number group displayed according to selection changes.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
36 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
6.9
6.
Setup of DAU
Analog (When the JCY-1700S is chosen to maintain, this screen does not be displayed.) How to set the connecting information of the analog signal output equipment is explained. Input the parameter for converting an output value (%) into a real value(displayed). Set up the connected CH as “Enable”. → The data of an disable CH is not recorded. In order to record the right data, be sure to set up the input signal type information and a coefficient conversion formula. Setting data is used with playback software.
6.9.1 6.9.2 6.9.3.2 6.9.3 6.9.3.1 6.9.3.3 6.9.3.4 6.9.3.5
6.9.1 Serial CH Select the Serial CH of the DAU that is the object of setup (Connected AIU). 1) Select CH Select CH from CH15 and CH16 whichever connects to the AIU (NQA-4091A). If "TYPE" setup of Selection CH (setup in a Serial screen) is not "A/D", all items will be in an input prohibited state. When displayed in the state of input prohibition, check a setup of a "Serial screen."
6.9.2 Calculate Set up the coefficient of the formula which converts the output value (%) of the AIU into a real value(displayed) with the following procedure. -- procedure --1 Select the analog CH to set up. -2 Input the minimum value of the analog signal output equipment (real value) into the “Equipment value” field of “Low Point”. -3 Input the A/D conversion value equivalent to an input value into a "Sentence Value" field. -4 Click [ Set ] button of “Low Point”. -5 Input the maximum value of the analog signal output equipment (real value) into the “Equipment value”
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
37 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
-6 -7 -8 -9 -10
6.
Setup of DAU
field of “High Point”. Input the A/D conversion value equivalent to an input value into a "Sentence Value" field. Click [Set] button of “High Point”. Click [Calculate] button. The coefficient computed by the formula is set as A and B coefficient item of the object analog CH. When [Check] button is clicked, the value which changed into the real value the A/D conversion value (%) then received by the conversion formula is displayed on the "Check value" field. Check the conversion formula is correct. Redo in order of procedure “-2”--”-8” when it is not correct.
The manual input and a receiving input are possible for the "Sentence value" item of A/D conversion value(%). When you click the [Receive] button, the A/D conversion value is set into the "Sentence value" field. In the case of receiving, operation will be performed after operating as the measured value of object equipment (real value) becomes maximum / the minimum value inputted into the "Equipment value" field. ► A/D conversion value ◄ A/D conversion is changed into ±100% of output value to an input full range. When a minus range does not exist, it becomes 0% - +100%.
Conversion formula y=A1*10A2x+B1*10B2 y=Equivalent, x=A/D conversion value, A1, A2, B1, B2=Coefficient
6.9.3 Analog CH1-CH8 Input the information of the connection equipment which is for connecting to the AIU. 6.9.3.1 Enable Input the existence of the sensor equipment for connecting to each CH of the AIU. In setting it as those with connection, please click and check the "Enable" check box. y Enable: [9] (checked) y Disable: [ ] (unchecked) Keep in mind that it does not receive the CH data which has not carried out by a valid setup.
6.9.3.2 Input Signal unit Select the data unit of receiving signal. Registration ID
Data unit
00
-
01
deg
02
min-1
03
rpm
04
m/s
05
km/s
06
knots
07
MPa
08
Pa
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
38 / 100
Maintenance Software Manual.doc
6.
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
Setup of DAU
6.9.3.3 Input signal type information Select the type information acquired with the receiving data of each Analog CH. Multiplex registration is forbidden, because same information is not collected from multiple sentences. Recording items
No.
Character string displayed
Rudder order and response
01
Rudder order ,manual
030
02
Rudder response ,manual
009
03
Rudder order ,automatic
011
Rudder response ,automatic
010
04 M/E RPM set order and response
05
M/E RPM set order
( CPP order )
06
M/E RPM actual response
( CPP order )
012 013
07
M/E RPM set order
100
08
M/E RPM actual response
101
09
Port M/E RPM set order
102
10
Port M/E RPM actual response
103
11
Starboard M/E RPM set order
104
12
Starboard M/E RPM actual response
105
13
CPP order
106
14
CPP response
107
15
Port CPP order
108
16
Port CPP response
109
17
Starboard CPP order
110
18
Starboard CPP response
111
19
Telegraph order position
021
20
Thruster order
018
21
Thruster response
019
22
Bow thruster order
112
23
Bow thruster response
113
24
Stern thruster order
114
25
Stern thruster response
115
26
Bow thruster pitch order
116
27
Bow thruster pitch response
117
28
Stern thruster pitch order
118
29
Stern thruster pitch response
119
Accelerations
30
Accelerations
022
Hull stress
31
Hull stress
023
Wind speed
32
Wind speed
120
Others
33
Other
999
6.9.3.4 Conversion formula The coefficient of the conversion formula computed by para. 6.9.2 is displayed.
6.9.3.5 Connection equipment information Enter the connection equipment information. 1) Equipment Enter the type of the equipment. 2) Model Enter the model name of the connection equipment. 3) Manufacturer Enter the name of the manufacturer. 4) Serial No. Enter the serial number of the equipment.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
ID
39 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
6.10
6.
Setup of DAU
Ethernet
How to set the parameters of Ethernet network connected to the DAU is explained. If the password for installation is used to login, this screen does not appear. Therefore, the ( ■ ) marks are put on all fields. The setting change for “Ethernet” is required only when build an option system. Do not change the setting when the JCY-1700 is shipped with standard composition. If the IP address is forgotten it will be impossible to use maintenance via the LAN connection.
( ■ ) 6.10.1 ( ■ ) 6.10.2
( ■ ) 6.10.3
( ■ ) 6.10.4
( ■ ) 6.10.5
6.10.1 MAC address ( ■ ) The MAC address is displayed. The MAC address is a unique address assigned to the Ethernet communication adapter. It is registered at the factory and should never be changed.
6.10.2 System ( ■ ) Set the common parameters of the Ethernet. 1) Subnet mask 255.255.255.0 2) Default gateway 192.168.110.100 This is needed when the UDP signals from the VDR are transmitted to another LAN network via a router. 6.10.3 RCU ( ■ ) Set information of RCU. 1) IP address 192.168.110.3 2) Port No. y For DAU: y For receiving of time correction signals:
5000 7000
6.10.4 DAU ( ■ ) Set parameter about Ethernet of DAU. 1) Standard IP address 192.168.110.100 2) Port No. y For RCU: y For Option/Maintenance PC:
5000 6000
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
40 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual y
For receiving of time correction signals:
6.
Setup of DAU
7000
The actual IP addresses of DAU1 and DAU2 are obtained by adding the unit number to the standard IP address as below. y DAU1: 192.168.110.101 y DAU2: 192.168.110.102
6.10.5 Option/Maintenance PC ( ■ ) Set the IP address of the PC that is connected to VDR. 1) Option PC IP address of the PC as a real-time monitor (option) 192.168.110.200 2) Maintenance PC IP address of the maintenance PC 192.168.110.200 3) Port No. The port number to which real-time monitor signals are transmitted y Sensor (NMEA) data: 50000 Notice that when the optional PC is not used, the IP address of the maintenance PC (192.168.110.200) is used as the default setting. When any optional system is to be setup, its IP address needs to be renewed. The IP address indicates where real-time signals (UDP/IP) are transmitted.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
41 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
6.11
6.
Setup of DAU
Configuration
How to set the operation parameters of DAU is explained The display does not appear if the password for maintenance is used to login. Normally there is no need to change the setting values. The settings should be updated only when an option system is being setup.
( ■ ) 6.11.1 ( ■ ) 6.11.1.1
( ■ ) 6.11.1.2
6.11.1 Real-time Monitor Use this setting to enable the real-time output (option). Set each output channel “Enable” or “Disable”. 6.11.1.1 LAN Set the channel “Enable” or “Disable”, though which data is transmitted to the LAN port. 6.11.1.2 COM Set the channel “Enable” or “Disable”, though which data is transmitted to the COM port. The reason for the COM port being used is due to the anticipation of the DCB of the DAU being used to serve other units. However, COM port is not to be used for the VDR.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
42 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
7.
7.
System operation check
System operation check Use a real-time monitor function to check that the operation and wiring state of each unit are normal. ♦ Check procedure
7.1
No.
Check items
Execution Function
Clause
1
NMEA sentence data
2
Radar image data
3 4
Audio data Microphone test
Monitor (M) -- DAU (D) Monitor (M) – Dry Contact (C) Setup (C) -- FGB (F) or Monitor (M) -- Radar (R) Monitor (M) -- Audio (A) Monitor (M) -- Event (E)
7.1 7.6 7.2 or 7.3 7.4 7.5
NMEA Sentence Monitor
- DAU (D) -
Monitor the NMEA sentence data which is collected in the DAU on real time, and check the sentence specified by the installation drawings is collected correctly. Be sure to check the collecting data of all channels. ● Record sentence setup ● Wires between each equipments
7.1.1 Starting 1) Click “DAU (D) “ in the Monitor (M) menu, and then select the DAU to monitor from DAU1(A) and DAU2(U).
The real-time monitor Window starts. 7.1.4 7.1.2
7.1.6
7.1.3 7.1.8 7.1.5 7.1.7
7.1.2 Setup of monitor conditions Set up the monitor conditions. When the PC of low specification is used, monitor every 1 CH. If the monitoring of two or more CH(s) is carried out simultaneously, the rate of a CPU load becomes 100%, and operation becomes impossible. When operation is impossible, the task manager of Windows is started by ++ . Please terminate the maintenance software.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
43 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
7.
System operation check
7.1.2.1 Selecting the monitor CH of DAU. Select the CH to monitor. Click the CH to monitor in the pull down menu. CH17 - CH19 The monitor of the recorded sentence when a contact signal is input into the RCU. Refer to 5.7.7
7.1.2.2 Selecting the monitor data type. Click the selection button of data type (“Recording data” / ”All data”) to monitor. ●
“Recording data”: Monitors the sentence data which is recorded in the VDR. The sentence which is not recorded is not displayed even if it has received. The monitor data is displayed by the sentence format currently recorded in the VDR.
●
”All data”:
Monitors all data which the DAU receives. The sentence data which is not recorded on the VDR is also displayed.
“All data” monitor It is used when the DAU begins receiving NG. When wiring is reverse-connected, the data which carried out character transformation is displayed.
7.1.3 The start and stop of the monitor Control the start and stop of a monitor. 1) Start of the monitor Click [START]button. The real time monitor of the data specified by the para. (7.1.2) is started. 2) Monitor stop Click [STOP]button. The real time monitor of the data specified by the para (7.1.2) is stopped. ●
”Recording data” The addition and deletion of the CH to the monitor can be operated freely.
●
”All data” Only independent CH can be monitored. Reception data is monitored when receiving. If the monitoring of two or more channels is carried out simultaneously, data will be mixed and they will be displayed.
7.1.4 Display of monitor CH The background color of CH that is being monitored becomes green.
7.1.5 Pause of monitor The pausing and restarting of monitor are controllable. 1) Pause Click [Pause] button. 2) Restart [Pause] button is changed to [PLAY]button during the pausing. Click [PLAY] button.
7.1.6 Clear monitoring window The monitoring window can be cleared. Click [Clear] button.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
44 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
7.
System operation check
7.1.7 File saving Monitor data can be saved in the file. 1) Specification of a “File saving” Click [Browse] button to select the saving folder. The saving file name is being fixed to RtMonitor1.txt. 2) Save start Click [SAVE START] button. The sentence data which is monitored can be saved in the text file after the save starting. 3) Save stop [SAVE START] button is changed to [SAVE STOP] button during the saving. Click [SAVE STOP] button. And saving file is ended.
7.1.8 Quitting procedure The quitting a real-time monitor should use the following procedure. An error dialog is displayed when it is not per procedure. 1) Stop monitoring Stop all of the CH which is monitoring. 2) Quitting a real-time monitor Click [Close] button. When the maintenance software is quitted, please make sure that a real –time monitor has stopped Reboot DAU, when the maintenance software has been quitted without stopping a real-time monitor. The output of real-time data stops.
7.2
Radar Image Monitor 1
- FGB (F) -
Check that the radar image data which is made to display on WEB. Check normal operation of the FGB. ● Image capture setup ● Rader wiring Difference between radar image monitor 1 and 2 Monitor 1:
The captured image will be displayed by expanded equally. And the quality of image can be checked. Monitor 2: The image currently recorded by VDR can be checked at real time. A reduction indication of the picture is given on all screens at PC monitor. Check the quality of image of the capture picture at first using a monitor 1.
7.2.1 Starting maintenance mode of FGB 1) Startup of the FGB Maintenance Mode Click on “Control” in the “Control” menu boosts up the control function.
2)
Starting Maintenance Mode of the FGB Click [ START ] in “FGR maintenance mode.”
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
45 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
[ START ]
7.
System operation check
[ STOP ]
Do not close “Control Window” This window is needed when ending “FGB maintenance mode”.
3)
FGB Error Display While VDR is in operation, MCB is sending a command to the FGB to capture an image. This function needs to be shut down during the maintenance of the FGB. For this purpose, the MCB cuts itself away from FGB in order to make the FGB free from its interference. This is called the FGB maintenance mode. Once the FGB is set in the maintenance mode, the FGB error is displayed on the internal operation panel of RCU.
4)
Starting FGB Maintenance Select “FGB” in the SETUP menu. FGB maintenance WEB starts.
5) FGB Maintenance WEB All the maintenance of FGB is done on this WEB page.
7.2.2 FGB Maintenance WEB Although FGB Maintenance Web has a lot of functions, only RADAR image monitor functions are explained here. File Back
7.2.2.1 7.2.2.2
7.2.2.1 Capturing RADAR image RADAR image can be captured and displayed in the WEB. 1) Image capture Click “Capture Image”, and the RADAR image at the time of the click is captured.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
46 / 100
Maintenance Software Manual.doc
7.
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
System operation check
2) Display of result FGB displays the result of the capture. Confirm that it is “OK”. After confirmation, click the [Return] button and go back to the FGB Maintenance WEB. → In case the result is “NG”, do it again. 3)
Display of captured image Click “PNG IMAGE”, and the captured image appears. Procedures: ▪ Click [Capture IMAGE] ▪ Confirm the result and [Return] ▪ Click [PNG IMAGE] ▪ RADAR image displayed ▪ Check the captured image
7.2.2.2 Switching RADAR JCY-1700 can capture the images of the two RADAR devices by switching them. By default, the parameter of CH1 is used for the setting of capture operation.
1)
Selecting the parameter for Capture Click on [CH1.txt] selects the parameter of CH1 for capture. Click on [CH2.txt] selects the parameter of CH2 for capture. For this switching operation, the parameters of the FGB need to be changed accordingly. When two different type RADAR units are used, which parameter should be used as the setting value of the capture conditions needs to be determined.
7.2.3 Quitting of FGB maintenance 1) Quitting FGB Maintenance WEB Click the “X” button in the upper right corner of the window. 2)
Quitting FGB Maintenance Mode Display the “Control” screen that has been started in “7.2.1 Click the “STOP” button in “FGB maintenance mode”.
2)”.
3) Quit “Control” Click the “X” button in the upper right corner of the window and close the window.
7.3
Radar Image Monitor 2
- Radar (R) -
Monitor the Radar Image Monitor which is recorded in the VDR at real time to check the operation is working correctly.
7.3.1 Starting Click “Radar (R)“ in the Monitor (M) menu.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
47 / 100
Maintenance Software Manual.doc
7.
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
System operation check
The real time monitor application starts.
7.3.2 Radar image real time monitor operation There is no operation. The image which the VDR is recording is displayed automatically. The image is updated in an interval of 15 seconds as well as a record interval. The monitored image is displayed later than the record time several seconds
7.3.3 Quitting procedure Click [×] button on the upper right of the Window.
7.4
Audio Monitor
- AUDIO (A) -
Monitor the Audio data which is recorded in the ARB at real time to check the operation is working correctly. ● Microphone unit operation ● Wiring between the RCU and Microphone unit or VHF transceiver
7.4.1 Starting Click “AUDIO (A) “ from Monitor (M) menu.
The audio real time monitor application starts.
7.4.3
1)
7.4.3
2)
7.4.2
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
48 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
7.
System operation check
7.4.2 Monitor CH selection Click the selection button of CH to monitor. ▪ Audio1: MIC1-- MIC3 ▪ Audio2: MIC4-- MIC6 ▪ Audio3: MIC7-- MIC9 ▪ VHF : VHF1-- VHF3 Select the CH to monitor. More than two CH cannot be played at the same time. For each connecting unit (MIC1,2,3,4,5,6,7,8,9, VHF1,2,3), connect only one unit to check the operation. → Each monitor CH is mixed by 3 input signal. For checking that each unit is correctly working, it is necessary to connect only one unit to monitor.
7.4.3 Control of monitor start / stop. 1) Start playing Click [►] button. The Audio of selected CH is outputted from speaker at real time. * Keep in mind that a sound is not outputted unless the PC speaker is "effective." 2)
Stop playing Click [■] button to stop monitoring. The monitored sound is played about one second later than sound source.
7.4.4 Change of Monitor CH Follow the following procedure, when changing the monitored sound CH. Stop playing → Changing monitor CH → Start playing
7.4.5 Quitting procedure Click [×] button on the upper right of the Window.
7.5
Event Monitor
- Event (E) -
Monitor the operation event of VDR at real time to check that VDR system is working correctly. Microphone connection setup Check that all the connected microphone test results are normal.
7.5.1 Start procedure Click “Event (E) “ from Monitor (M) menu.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
49 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
7.
System operation check
The real time monitor application starts. [Connect]
[START]
[STOP]
7.5.2 Starting real time monitoring of Event Monitor of real time event starts. 1) Circuit connection Click [Connect] button. The display of [Monitoring start] button becomes effective. 2)
Monitoring start Click [Monitoring start] button to start monitoring.
Although the menu and button which have not been indicated in this manual exist, since it is the function which is not usually used, explanation is omitted.
7.5.3 Changing of display language A display language of Event can be changed to Japanese. 1) Selection of display language Click “Language” in the “View” menu, and then choose from English and Japanese.
7.5.4 Quitting procedure The quitting of a real-time monitor should follow the following procedure. 1) Stop of monitoring Click [Monitoring stop] button. 2)
Quitting of real time monitoring Click [×] button on the upper right of the Window. When the maintenance softwrae is quitted, please make sure tahat the a real-time monitor stopped. Reboot RCU, when the maintenance software has been quitted without stopping a real-time monitor. The output of real-time data stops.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
50 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
7.6
Dry Contact Data Monitor
7.
System operation check
- Dry Contact (C) (When the JCY-1700S is chosen to maintain, this function can not be operated.)
Monitor the dry contact data which is collected in the NCT-57/63 on real time, and check a dry contact state specified by installation drawings is collected correctly. Be sure to check the collecting data of all channels. This monitor analyzes the contents of NMEA sentence data outputted from the NCT-57/63, and a dry contact state is indicating by an icon. ● NCT-57/63 setup ● Wires between each equipments
7.6.1 Starting 1) Click “Dry Contact (C) “ in the Monitor (M) menu, and then select the DAU to monitor from DAU1(A) and DAU2(U).
The real-time monitor Window starts.
7.6.2
7.6.4 7.6.8
7.6.3 7.6.5 7.6.7 7.6.6
7.6.2 Selecting the monitor CH of DAU. Select the CH (CH13 or CH14) of DAU which connected the NCT-57/63 to monitor. Click the CH to monitor in the pull down menu.
7.6.3 The start and stop of the monitor Control the start and stop of the monitor. 1) Start of the monitor Click [START] button. The real time monitor of the data specified by the para. (7.6.2) is started. 2) Monitor stop Click [STOP] button. The real time monitor of the data is stopped. The monitor of both channels cannot be carried out simultaneously. When you want to monitor of other CH, terminate monitoring CH now.
7.6.4 Display of monitor CH The background color of CH which is monitored becomes green.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
51 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
7.
System operation check
7.6.5 NMEA sentence monitor window The NMEA sentence which received from NCT-57/63 is displayed.
7.6.6 Dry contact state monitor window The contents of the NMEA sentence which received from NCT-57/63 are analyzed. The state of dry contact signal is displayed legible by the lamp or an icon.
7.6.6.5
7.6.6.3
7.6.6.4
7.6.6.2
7.6.6.1 How to display the dry contact state In order to check the dry contact state by a monitor window, it is necessary to change the dry contact state. If the dry contact state changes, the NMEA sentence will be outputted from NCT-57/63. ● Sentence output timing of the NCT-57/63 ▪ when a dry contact state changes. ▪ In order to show the condition of all CH(s) connected, it outputs periodically in a cycle of 5 minutes.
7.6.6.2 General dry contact ( except Door status and Engine telegraph ) A dry contact state is displayed with a lamp icon. ▪ Green lamp: A target status is normal. ▪ Red lamp : A target status is abnormal.
7.6.6.3 Dry contact of Door status A dry contact state is displayed with a door icon. ▪
:
A door is open.
▪
:
A door is closing.
7.6.6.4 Dry contact of Engine telegraph The channel which connected the engine telegraph is displayed by yellow lamps. Click any yellow lamps, and it will change to the window for an engine telegraph.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
52 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
7.
System operation check
"Engine telegraph position", "Sub-telegraph position", and "Operating location" The present position is displayed by a green lamp. When the [Close] button is clicked, an engine telegraph window will be closed and it will return to a dry contact state window.
7.6.6.5 Setting data version of the NCT-57/63 When the setting data version of the NCT-57/63 is old, the warning message of background red is displayed as follows. When this warning is displayed, receive the setting data of the NCT-57/63, and transmit the received data as it is. Maintenance software updates the received setting data to the latest version automatically. Refer to para. "9.2.4.3", "9.2.4.4" and "9.2.5" for operating procedure.
7.6.7 Clear monitoring window The monitoring window can be cleared. Click [Clear] button.
7.6.8 When a monitoring dry contact state is wriong. When the monitoring dry contact state shows contrary information to the outputting information of the connected unit, correct the setting data of the NCT-57/63. Since the dry contact atate (OPEN/CLOSE) which shows a normal state is set up conversely, change the setting data of the NCT-57/63 with reference to para. “9.2.2.3.”
7.6.9 Quitting procedure The quitting a real-time monitor should follow the following procedure. An error dialog is displayed when it is not as a procedure. 1) Stop monitoring Stop all of the CH which is monitoring. 2) Quitting a real-time monitor Click [Close] button. When the maintenance softwrae is quitted, please make sure tahat the a real-time monitor stopped. Reboot RCU, when the maintenance software has been quitted without stopping a real-time monitor. The output of real-time data stops.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
53 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
This page is intentionally left blank
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
54 / 100
Maintenance Software Manual.doc
7.
System operation check
8.
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
8.
Recording data check
Record Data Check Check the contents of both the record data of a capsule and a PC card with playback software. ●
Check procedure No.
Check Items
Execution function
Clause
1 2
Download of record data in the HVR Conversion of record data • Capsule data • PC card data Playback data
Data (D) -- HVR backup (H) Data (D) -- Data Convert (V)
8.1 8.2
Data (D) -- Playback (P)
8.3
3
8.1
Download of capsule Record Data
- HVR backup (H) -
The data currently recorded on the capsule can be downloaded to direct PC by the LAN circuit.
8.1.1 Start Data download is started after stopping data record of VDR. Be sure to follow this procedure. If download is started at recording, the LAN circuit between RCU and a capsule will be disconnect and RCU will give an error.
1) Starting of the output control command of monitor data Click “Control (R) “ from Control (R) menu to start the Control function.
2)
Stopping the data recording Stop the data recording of VDR. Wait for 1 minute after clicking [STOP] button of “Remote control” function until recording is stopped.
[RESTART]
3)
[STOP]
Click “HVR backup (H) “ from Data (D) menu.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
55 / 100
Maintenance Software Manual.doc
8.
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
Recording data check
The real time monitor application starts.
8.1.2
8.1.3
8.1.5
8.1.6 8.1.4
8.1.7 8.1.4
● When the Maintenance PC cannot communicate to the RCU or the software version of RCU software is older than "2.0.0", the dialog for selecting the type of capsule will be displayed. Refer to the clause 8.1.7 for details. Select the type of capsule which is connected.
8.1.2 Saving folder specification Specify the folder where the downloaded backup file is saved. 1) Dialog display Click [Browse] button. 2)
Saving folder specification The folder saved by the displayed dialog is specified.
8.1.3 Selecting the download data Select the record data to download. 1) Data selection Click inside of the check box of the data type to download to put [9] mark. Since it is all data selections by the default, remove the check of unnecessary data.
8.1.4 Setup of the amount of download data Set up the amount of data to download. 1) When all data is downloaded Click inside of the checkbox of “ALL” to put [9] mark. 2)
When the download capacity is adjusted Click inside of the check box of “ALL” to take out “[ ]”. The data capacity downloaded by operating a slide bar is adjusted. The capacity downloaded as a guide is displayed by %. Download goes back from the newest data and downloads old data. When requiring only the newest data, several% of download is enough. Download of the amount of whole capacity requires about 3 hours. Since data capacity is specified and downloaded, in NMEA sensor data, audio data, and image data, the time width reproduced is different. As for the data of the second half(New in the record) replayed although the time when playback is started(old in the record) is not in agreement, all data will be gathered.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
56 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
8.
Recording data check
8.1.5 Starting download Start downloading. 1) Starting download Click [START] button. 2) Progress display Progress of download is displayed by Progress bar corresponding to each partition.
8.1.6 Canceling Download Download can be canceled in the halfway of the downloading. [START] button changes to[CANCEL]button when downloading. Click [CANCEL] button. The download application is stopped when canceling. The downloaded data can be played even if canceling in the halfway, because it is effective.
8.1.7 Selecting the type of capsule Use this function to change the type of capsule. 1) Displaying the dialog for selecting Click the [Capsule type] button, and the following dialog will be displayed.
2) Selecting the type Click the selection button of the capsule which is connected and then click the [OK] button. For the JCY-1000 (the old type for VDR) NDH-288A NDH-288B For the JCY-1000/1700 (the present type for VDR) NDH-316 For the JCY-1700 (the future type for VDR) NDH-317 For the JCY-1700S (the present type for S-VDR)
8.1.8 Quitting procedure Operate the following procedure when the quitting of the download.
8.2
1)
Quitting of a download function Click [EXIT] button to quit the download application.
2)
Restart recording Click [RESTART] button in the Control screen to restart recording the data which is canceled before download starts.
3)
Quitting of Control function When Control function is not continued to use, click [×] button on the upper right of the Control screen.
Conversion of Record Data
- Data Convert (V) -
It is made to convert so that recorded data by JCY-1700 can be replayed by playback software for JCY-1700.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
57 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
8.
Recording data check
8.2.1 Start Click “Data Convert (V) “ from Data (D) menu.
Data conversion application starts.
8.2.2 8.2.3
8.2.4
8.2.6 8.2.5
8.2.2 Selecting backup data type Select the JCY-1700 backup data type made applicable to conversion. Select from a "PC card" and the "capsule data." 1)
PC card data Click [ATA / HVR] button to display “ATA MODE” for the recorded data in the PC card.
2) Capsule data Click [ATA / HVR] button to display “HVR MODE” for the downloaded data from the capsule at “clause 8.1 Download function”.
8.2.3 Selection of the object file Specify the route folder of the file set as the object of conversion. 1)
PC card data Click [Read browse] button to specify the drive which is currently assigned to the PC card.
2) Capsule data Click [Read browse] button to specify the route folder of downloaded file.
8.2.4 Specification of the saving folder of the conversion file Click [Save browse] button to specify folder for saving the converted file. When converting all record data, about 5GB of availability is required.
8.2.5 Setup of conversion conditions detail. Set up the conversion conditions detail.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
58 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
8.
Recording data check
1) Display of the detailed setting dialog Click [Details] button to display the detailed setting dialog.
2)
Selection of the data for conversion Click into the check box of the data for changing to put the checked mark. All default data is selected. Take out the [9] mark from the data which is not needed.
3)
Deleting the ex-file. Click into the check box of ”Delete file after extracting” to take out the checked mark if recorded data before changing is not deleted.
4)
Conversion of Audio data Click into the check box of ”WAV extract” to take out the checked mark if the audio data is not changed into the playable WAV file. It is impossible to understand the contents of the capsule backup data because the data is downloaded as one of the DAT file, The record situation can be understood, if the audio data is decomposed as G726 compressed file. Audio file does not need to be changed into WAV file if playing with audio is not needed. Moreover, there is the selection that only the needed part can be changed to WAV file after the converting as G726 file. Conversion abbreviation can be selected because the converting to WAV file takes long time. → 80% of the time to convert is for the WAV file.
5)Conversion to recording format of the PC card When the data downloaded from HVR is converted to the PC card format, click the check box of "PC CARD FORMAT" to put [9] mark. This conversion function will be used when a data downloaded from HVR is replayed with the playback software for JCY-1700. It is unnecessary in a maintenance.
8.2.6 Conversion start Click [Extract] button to start the conversion of the data. The progress situation of conversion can be checked by progress bar.
8.2.7 Quitting procedure Click [×] button on the right upper of the Window.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
59 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
8.3
The Data Playback
8.
Recording data check
- Playback (P) -
The converted data at the clause 8.2 can be played back with this function. The configuration of playback can be set up.
8.3.1 Starting Playback Click ”Playback (P) - Playback (P) “ from Data menu.
Playback software starts.
8.3.2 Starting Setup Click ”Playback (P) - Setup (S) “ from Data menu.
Setup software starts.
Refer to the "playback - operation manual" for the operating instructions of playback software.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
60 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
9.
9.
Factory-shipments setup
Factory-shipments setup
Set up at the time of shipment inspection at a factory. Usually, it is not necessary to set up at the time of onboard installation. The setup change is needed in changing from the contents of a installation drawings. ●
Factory-shipments setting items
No.
Object unit
The contents of Setup
Execution function
clause
1
FGB CKA-129 Digital signal converter NCT-57/63 Analog signal input unit NQA-4091A
Parameter setting of the image capture
Setup (C) -- FGB (F)
9.1
Setting of the dry contact signal
Setup (C) -- Option (O) -- Dry contact Setup (C) -- Option (O) -- Analog
9.2
2 3
9.1
FGB Maintenance WEB
Setting of the A/D module parameter
- FGB (F) -
Set up the capture parameter of the radar image.
9.1.1 Starting procedure of FGB maintenance. Refer to 7.2.1.
9.1.2 FGB Maintenance WEB FGB Maintenance WEB has many functions. The functions required at least are explained. “File” [Back] Program version
9.1.2.1
9.1.2.2
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
61 / 100
Maintenance Software Manual.doc
9.3
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
9.
Factory-shipments setup
9.1.2.1 Download The setting field of FGB can be downloaded. 1) Setting file of CH1 Click [Capture1.txt]. The content of the file is displayed on the screen. Save the file using the file menu in the upper left of the window. The text editor software can edit the saved file. Click the [Return] button and go back to the FGB Maintenance WEB screen. 2) Setting file of CH2 Click [Capture2.txt]. The content of the file is displayed on the screen. Follow the same procedure written above.
9.1.2.2 Upload The setting file of FGB can be uploaded. By uploading, the capture conditions of FGB can be changed. 1) Setting file of CH1 Click [Capture1.txt upload].
Click [Browse] button, and then select the file to be uploaded, and click the [UPLOAD] button. Click the [Return] button and go back to the FGB Maintenance WEB screen. 2) Setting file of CH2 Click [Capture2.txt upload]. Follow the same procedure written above.
If FGB is connected to JRC RADAR equipment, the setting file with optimum parameters is uploaded at the factory. And there in no need to set them again on site. However, if FGB is not connected to JRC RADAR equipment. In this case, the parameters need to be set on site after shipment. With the intension of reducing such an inconvenience, a new way of setting parameters is under consideration on our side. Please wait for a while. The FGB setting file extracted from system configuration information can be uploaded by this function. Refer to the clause 10.1.7 and 10.5.
9.1.2.3 Editing the FGB capture conditions Detailed information is omitted. When necessary, it will be provided. CAUTION in the process of downloading, editing, and uploading the FGB capture setting file: When editing the file, delete the first line. If you try to upload the file without deleting its first line, an error will be reported.
9.1.3 Quitting procedure of the FGB Maintenance Refer to 7.2.3.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
62 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
9.2
Setup of the DSC (NCT-57/63).
9.
Factory-shipments setup
- Dry Contact -
(When the JCY-1700S is chosen to maintain, this function can not be operated.) Set up the DSC (NCT-57/63) of the option unit.
Connecting to LAN of RCU directly can set up NCT-57/63 without connecting the PC to the NCT-57/63. ● Factory setup Simplex inspection: Can be set up with connecting directly to NCT-57/63 if COM port is used. System inspection: Can be set up NCT-57/63 by LAN connection as same as other equipment setup. ● Installation setup (when a change setup is required) Can be set up NCT-57/63 by LAN connection as same as other maintenance setup. -- Communication route -< Maintenance PC > -- < RCU (HUB) > -- < DAU > -- < NCT-57/63 >
9.2.1 Starting procedure Click ”Dry Contact” from ”Option (O) “ of Setup (C) menu.
Setup application starts.
9.2.2.2
9.2.2.4
1)
9.2.2.4
2)
9.2.2.4
3)
9.2.2.3 9.2.2.1
9.2.2.5 9.2.2.8
9.2.2.6
1) New setup Start from the procedure of the 9.2.2 clause when a setup data is created newly for the NCT-57/63. 2) Confirmation and modification of setting data in the NCT-57/63 Start from the procedure of the 9.2.4 clause when confirming and modifying a setting data in the NCT-57/63.
9.2.2 General dry contact Register the sentence data which NCT-57/63 output at the changing point (Open→Close, Close→Open) of a dry contact signal according to the following procedure. · Sentence data consists of type, status (Open / Close) and comment. · Creation of a sentence is the method which chooses the contents of the dry contact signal from a menu at each category.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
63 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
9.
Factory-shipments setup
9.2.2.1 Setting guide The dry contact signal information which can be selected is displayed by list in tree format. Refer to as a setting guide. The dry contact signal information is displayed list in tree format according to the signal content (category) selected with the pull-down menu in the operating procedure of the 9.2.2.4 clause. On the contrary, selected signal is set as a pull-down menu according to the list double-clicked in the tree format.
9.2.2.2 Connecting CH Select CH of NCT-57/63 which connected a dry contact signal. The sentence data for selected CH is created.
9.2.2.3 State of a dry contact signal Select the contents of a signal shown by OPEN or CLOSE. The contents set up by the sentence are different respectively. ( except Door status and Engine telegraph ) 1) General dry contact Select the dry contact state (OPEN/CLOSE) when the connected signal is a normal state.
2)
Dry contact of Door status Select the dry contact state (OPEN/CLOSE) when the connected door opens.
When the lamp of the state of a dry contact signal is displayed with playback software, a "normal state" will be indicated by green and a “non-normal state” will be indicated by red. When a contact signal means "Active" or "not Active", the contact state of "Active" is selected as a normal state.
9.2.2.4 Creating output sentence 1) Dry contact information Select the dry contact information from the pull-down menu of each category according to the connected signal. Although categories are prepared to 3 at the maximum, number of category to be set up is automatically determined by selected data. → Be sure to select a dry contact information from pull-down menu which can be set up. An unnecessary setup category is in an input prohibition state.. 2)
Identification number of a dry contact A signal of the same kind needs a setup of an identification number. Be sure to select the identification number since the pull-down menu will be displayed active. → Be careful not to select the same numeric value. The same sentence data will be created for difference input port.
3) Comment A comment can be added to the end of a sentence. Input the character strings which show the contents of a dry contact signal. As sentence information, the connection CH of NCT-57/63 is added automatically.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
64 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
9.
Factory-shipments setup
●
Caution Since a maximum length of a sentence is 82 bytes, even if a long comment is inputted more than 82 bytes are ignored.
9.2.2.5 Registering sentence data Click the [SET] button after all categories are selected and comment is inputted. The sentence according to the contents of selection is created, and it is added to a setup file.
9.2.2.6 List of registration sentences The list of the sentences added to the setup file is displayed. It double-clicks an object sentence, in changing the sentence or deleting. An object sentence is displayed the contents in a setting field. → Check that the connection CH number has changed to the number of the double-clicked sentence.
9.2.2.7 Registering all sentences The procedure from the 9.2.2.2 clause to the 9.2.2.5 clause is repeated, and all the sentences as the dry contact signal connected to the NCT-57/63 are added to the setup file. However, the dry contact signals of an engine telegraph are added according to the operating procedure from the 9.2.3 clause.
9.2.2.8 Deleting the sentence The sentence registered into the setup file can be deleted. 1)
Selecting a sentence Double-click the sentence displayed on the list. It checks that CH number for deletion is displayed on the connection CH field of the 9.2.2.2 clause.
2)
Deleting a sentence Click the [Delete] button.
When engine telegraph signals are not connected with dry contact signals, the procedure of the 9.2.3 clause is unnecessary.
9.2.3 Dry contact signals of engine telegraph The special window for registering of engine telegraph signals are prepared. 9.2.3.1 9.2.3.2
9.2.3.5
9.2.3.2
1)
9.2.3.2
4)
9.2.3.6
9.2.3.2
2)
9.2.3.4
9.2.3.2
3)
9.2.3.4
9.2.3.3
9.2.3.7 9.2.3.8 9.2.3.10
9.2.3.9
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
65 / 100
Maintenance Software Manual.doc
1)
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
9.
Factory-shipments setup
9.2.3.1 Special window for registering of engine telegraph signals Click ”Engine Telegraph” from ”Type” menu. The registering window of engine telegraph signals is displayed. The "ETL" sentence is created considering all dry contact signals for engine telegraph as a group. → The number of registration sentence is one.
9.2.3.2 Engine telegraph position Setup an engine telegraph position data according to the following procedure. 1) “Active” / “not Active” selection Select either “connected” or “disconnected” of the engine telegraph position data by dry contact signals. Since it is set as “connected” by the default, in not connecting, click and remove checks a [√ ]. If this field is set up as disconnected, the setting field will be in an inhibit state, and the object field of the "ETL" sentence will become a blank.
2)
Selecting connected dry contact signals On a selecting menu, all the signals of an engine telegraph position can be registered, the connected dry contact signal is necessary to select. Click and be removed checks a [√ ] at the check box of the disconnected signal, since all engine telegraph position set up to “connected” as default.
3)
Selecting connection CH Select the connection CH of NCT-57/63 with a pull-down menu.
4) Selecting state of dry contact signal Select a state of the dry contact signal (Open/Close) at the "Active".
9.2.3.3 Sub telegraph position Set up a sub telegraph position data. Setup procedure is the same as that of the 9.2.3.2 clause.
9.2.3.4 Operation position Set up a operation position data of engine telegraph. 1) “Active” / “Not active” selection Select either “connected” or “disconnected” of the operation position. Although setup procedure is the same as that of the 9.2.3.2 clause, if operation position is selected “connected.” Since a display changes to selective buttons type when "disconnected" is selected, select the operation position of engine telegraph. Select “Other” when operating position can not be specified. Operating position ‘s field of “ETL” sentence become a blank, when operating position is selected “other”.
9.2.3.5 Order or Response Select the sentence type (Order / Response) of engine telegraph signals.
9.2.3.6 Engine, Propeller position Select the position of an engine and a propeller shaft. - Single or on center line - Port - Starboard
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
66 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
9.
Factory-shipments setup
9.2.3.7 ETL sentence identification number Select the identification number in the case of registering two or more ETL sentences. When registering only one sentence, it is necessary to select as "01" by a default, but in registering two or more, set up a increment number. It can set up from "01" to "04."
9.2.3.8 Addition of Sentence Click the [SET] button at all field are inputted. The sentence according to the selection is created, and it is added to a setup file.
9.2.3.9 List of registration sentences Refer to the 9.2.2.6 clause.
9.2.3.10 Deleting the sentence Refer to the 9.2.2.8 clause. In deleting an ETL sentence, double-click a registered line with "S * " in the "CH" column. 9.2.4 Setup file operation Carry out required operation of the created NCT-57/63 setup file. - Saving as a files. - Opening a file. - Transmitting a setup data to NCT-57/63. - Receiving setup data from NCT-57/63. - New setup.
9.2.4.1 Saving as a file The setting data created in the procedure of the 9.2.2 clause and the 9.2.3 clause can be saved as a file. Click "Save" of the "File" menu. The dialog for inputting a file name is displayed.
9.2.4.2 Opening a file The saved file can be opened for confirming and editing setup data. Click "Open" of the "File" menu. The dialog for selecting a file is displayed.
9.2.4.3 Transmitting to NCT-57/63. The setting data created in the procedure of the 9.2.2 clause and the 9.2.3 clause can be transmitted to the NCT-57/63. Click "Transmit" of the "File" menu. The dialog for transmission and reception of a setup data is displayed. Refer to the 9.2.5 clause for operating procedure.
9.2.4.4 Receiving from NCT-57/63. The setting data of NCT-57/63 can be received. Click "Receive" of the "File" menu. The dialog for transmission and reception of a setup data is displayed. Refer to the 9.2.5 clause for operating procedure.
9.2.4.5 New setup The present display data can be cleared and setting data can be created newly. Click "New" of the "File" menu. All setting data are cleared.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
67 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
9.
Factory-shipments setup
9.2.5 Transmission and reception of a setup data (file) A click of "Transmit" or "Receive" of the "File" menu displays the dialog for transmission and reception. Transmit or receive after setting up transceiver condition.
9.2.5.5 9.2.5.4 9.2.5.7 9.2.5.3 9.2.5.2 9.2.5.6 9.2.5.1
9.2.5.1 Selecting communication circuit Click to select from ”LAN” connection and the direct connection of ”COM”. ●
When COM connection is selected, it becomes impossible to set up 9.2.5.2 and 9.2.5.3 .
9.2.5.2 Selecting DAU unit Select from “DAU1” and “DAU2” which are connected NCT-57/63, when LAN connection is made. Click any button to select.
9.2.5.3 Selecting NCT-57/63 Connection CH Select the serial CH (CH13 or CH14) of DAU which is connecting NCT-57/63 from the pull down menu.
9.2.5.4 Receiving setup data from NCT-57/63 Click [Receive] button. When reception completes, a dialog will be closed and it will return to a main window. * A “Receive” button becomes effective when "Receive" is selected with the menu of a main window. → A “Receive” button becomes invalid when "Transmit" is selected with the menu of a main window.
9.2.5.5 Transmitting setup data to NCT-57/63 1) Transmitting the setup file Click [Transmit] button. The setup data created on the main window are transmitted to NCT-57/63. * A “Transmit” button becomes effective when "Transmit" is selected with the menu of a main window. → A “Transmit” button becomes invalid when "Receive" is selected with the menu of a main window. Save setting data as a file before In transmitting and receiving. If transmission and reception are operated before saving a setup file, the following warning dialog will be displayed.
Click the [OK] button to continue transmission and reception. The dialog for saving a file is displayed. A communication link is started after saving file.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
68 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
9.
Factory-shipments setup
2) Confirming the DSC to set up Click the [Transmit] button and then the following dialog is displayed.
Check that DSC shown on the dialog is the same as DSC to set up. Click the [Yes] button when the DSC shown on the dialog is right. Transmitting the setup file to the DSC is started. Check items: • The number of DAU • The channel number of DAU which is connected to the DSC • The type of DSC (NCT-57 or NCT-63) When two DSC(s) are connected Accidentally, even if the setup file is transmitted conversely, the DSC cannot generate an error alarm. Wrong data will be recorded as a result. Be careful enough and operate it
3) Recording the setup file to the Capsule When the transmission of setup file to the DSC is finished, the following dialog will be displayed.
The setup file of DSC is recorded to the Capsule via ethernet link too. When the Maintenance PC can communicate to the capsule, click the [Yes] button. Transmitting the setup file to the Capsule is started. 4) Completion of a setting When transmission to the DSC and the Capsule completes, a dialog will be closed and it will return to a main window.
9.2.5.6 Program version Click [Version] button. The program version of NCT-57/63 is displayed.
9.2.5.7 Closing the dialog When closing a dialog, without transmitting and receiving, the [Close] button is clicked and it is closed.
9.2.6 Quitting procedure Click [×] button on the upper right of the Window.
9.2.7 Check the recording sentence data Check the recording sentence data with following information after installation 9.2.7.1 Generic dry contact signal The state of the dry contact signal is displayed on the field defined by "%C" of recording sentence data.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
69 / 100
Maintenance Software Manual.doc
9.
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
Factory-shipments setup
1)
Sentence data Check the definition field of "%C from the registering sentence in the list window of 9.2.2.6 clause.
2)
State of the dry contact When a state of the dry contact is changed, objective sentence will be outputted from NCT-57/63. Check that the character of "%C" field changes. ● Used character - "V" or "A": "V" = Normal, "A" = Abnorml - "N" or "H": "N" = Normal, "H" = Abnormal - "O" or "C": "O" = Open, "C" = Close
9.2.7.2 Engine Telegraph data Since all the dry contact signals for an engine telegraph are outputted as a "ETL" sentence, the object field is shown below. ● $XXETL, ,” 1)”,” 2) ”,” 3) ” ,” 4) ”,” 5) ” *hh 1) Order and Response O = Order A = Response 2)
Engine telegraph position 00 = STOP ENGINE 01 = [AH] DEAD SLOW 02 = [AH] SLOW 03 = [AH] HALF
3) Sub telegraph position 20 = S/B (Stand-by engine) 4)
04 = [AH] FULL 05 = [AH] NAV. FULL 11 = [AS] DEAD SLOW 12 = [AS] SLOW
30 = F/A (Full away – Navigation full)
Operation position B = Bridge P = Port wing S = Starboard wing W = Wing (port or starboard not specified)
5) Engine, propeller shaft position 0 = single or on centre-line Odd = starboard
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
13 = [AS] HALF 14 = [AS] FULL 15 =[AS] CRASH ASTERN
70 / 100
Maintenance Software Manual.doc
40 = F/E (Finish with engine)
C = Engine control room
Even = port
E = Engine side / local
9.
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
-
Factory-shipments setup
Reference –
● Specification of the setting file It is divided by “,(comma)” between each setting value. ( “CSV” format) No.
Item
Data
Byte
Note
1
Command + dry contact POINT signal No.
2
The logic of dry contact
0 or 1
1
Normal OPEN: 0
3
Judgment character
**
2
First character: Character for outputting when it is Normal. Second Character: Character for outputting when it is Active.
NMEA sentence header
$
1
Header of NMEA sentence
Talker ID
**
2
Talker ID of NMEA sentence
3
Sentence ID of NMEA sentence
4
*** Unbalanced
Sentence ID
***
5
Contents of NMEA sentence
Unfixed
6
Terminator code
0D0A
Sample)
Unfixed
· POINT: Registration command · Space code: Usually, although it is 2-3 [Byte], it is processed as unknown. → Dry contact signal No. is the maximum of 3 characters before “,” · Dry contact signal No.: Maximum of 3 characters. → It is recognized between the space (before) and the comma (after).
"Comma" is used as a delimiter of each item of the contents of a sentence. A "judgment character" is inputted into the item which .%c defined, and a sentence is generated
2
Maximum of 79 characters to “$”~ ”Terminator” Because of checksum for NMEA sentence ”*xx” is not included
POINT 1,1,OC,$VRDOR,E,A,WT,,001,001,%c,,001_No.1_Door POINT 2,1,OC,$VRDOR,E,A,WT,,001,002,%c,,002_No.1_Door
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
Normal CLOSE: 1
71 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
9.3
Setup of Analog Signal Input Unit (NQA-4091A)
9.
Factory-shipments setup
- Analog -
(When the JCY-1700S is chosen to maintain, this function can not be operated.) Set up the A/D unit (option) built in DAU or the option unit (NQA-4091A). The A/D unit with built-in DAU is explained as NQA-4091A after this. The basic modules of the A/D unit with built-in DAU and the NQA-4091A are same. ●
This function is not used to maintain the optional built-in A/D converter board to the DSC (NCT-57/63). The setting of the built-in A/D converter board to the DSC is operated with the strap pins on the PCB
The setup of NQA-4091A is possible via LAN of RCU without connecting PC with NQA-4091A. ● Factory setup Simplex inspection: Can be set up with directly connecting to NQA-4091A by using COM port. System inspection: Can be set up NQA-4091A by LAN connection as same as other maintenance setup. ● Installation setup (when a change setup is required) Can be set up NQA-4091A by LAN connection as same as other maintenance setup. -- communication route -< Maintenance PC > -- -- < DAU > -- < NQA-4091A >
9.3.1 New setting preparation ● ●
The setting preparation according to this item is required only at the time of a new setup at a factory. In changing the range of the A/D module (6B12) set up at the factory, there is no necessity for "new setting preparation." → Start from the clause 9.3.2. However, when A/D module needs to be added (Changed), "new setting preparation" explained according to this item is needed.
In setting up A/D module (6B12) newly, mount A/D module according to the following. 1)
Take out 6B12 module that is mounted on the Slot1 (configuration slot) of back plane with D-SUB25 connector. → Take it out upward after taking out the screw for holding 6B12.
2) Insert 6B12 to set up into Slot 1(configuration slot). →
Only setup of 6B12 module which is in Slot 1 can be changed. Slot 1 (configuration slot)
3) Jumper setup Short-circuit with the configuration jumper (W1) on the left of Slot 1 (configuration slot) of back plane. Initial setting of a A/D module can be set by short-circuited with configuration jumper (W1). The communication rate at the time of initial setting is compulsively set to 9600bps. It is necessary to change a communication rate setup of DAU into 9600bps.
4)
Baud rate setup of DAU
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
72 / 100
Maintenance Software Manual.doc
9.
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
Factory-shipments setup
Use the Setup function (See 6.6) of DAU and change the communication rate of the A/D connection CH into 9600bps.
9.3.2 Starting Click the “Analog” from “Option” in the “Setup” Menu.
Setup application starts. 9.3.6
9.3.8 9.3.10
9.3.5
9.3.11
9.3.3 9.3.7 9.3.9 9.3.4
9.3.3 Jumper setup Follow the jumper (W1) setting that is set at 9.3.1 to select. · Pin Open: When it is a state at the time of shipment and a setting change of a range is made · Pin Close: When a new setup is performed (in the case of 9.3.1 new setting preparation) Since new setting preparation of the 9.3.1 is omitted, when a range setup at the time of onboard equipment changes, the jumper setup has "Jumper Open" selected.
9.3.4 Communication circuit setup Select either the "LAN" connection via DAU, or the direct connection by "COM." ● When COM connection is chosen, it becomes impossible to set up 9.3.5, 9.3.6. 9.3.5 DAU unit selection Choose from “DAU1” and “DAU2” which are connected NQA-4091A, when LAN connection is made. Click any selection button to choose.
9.3.6 NQA-4091A Connection CH Setup Select the serial CH of DAU which is connecting NQA-4091A. Choose from CH13 and CH14 from the pull down menu.
9.3.7 A/D module address selection Select A/D module address which is for setting up. The address selection is needed only when the configuration jumper is “Open”. When it is “Short”, only A/D module of slot 1 can be setup. Selection of the A/D module address is not need.
1)
Pin Open Setup (Change setup) Select the address number of A/D module to make a setting change of a input range.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
73 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
2)
9.
Factory-shipments setup
Pin Close Setup (New setup) The A/D module which can be set up is limited to the module is set to the slot 1. → Changing is not needed, even “00” is selected in the default. The registration address of a A/D module is using ”00”-”07”. Keep in mind that A/D module of ”00”-”07” address is mounted on the Analog input CH01-08 at the time of factory shipments.
9.3.8 Download of setting data Click [Read] button to download the current setting data. The current setting data is displayed in each setting item. If the configuration jumper is shorted, the A/D module address is setup to the slot 1 is displayed at the address field.
9.3.9 Editing the setting data 9.3.9.1 Shipment setup (new setup) Set all items as VDR specification. Set up an input range according to the installation drawings.
9.3.9.2 Installation setup (change setup) Change only an input range according to specification of the connection equipment. 1. The item which can be changed at the onboard is only an input range [Range]. Since it may become impossible to use in this system if other items are changed, do not change. 2. If it is changed to voltage range (+/- 10V or +/-1V Range etc) from +/- 20mA Range, 50Ω current conversion resistor (AC1381) will be needed. Prepare in beforehand. · 50Ω current conversion resistor (AC1381) code: 5EZFE00015 3. Conversely, if it is changed from +/- 20mA Range to voltage range (+/- 10V or +/- 1V Range etc), 50Ω current conversion resistor (AC1381) must be removed.
9.3.10 Data setting Set up the contents which are displayed by each setting field. Click [Program] button to set up. In a new setup, set all A/D modules to a slot 1 one by one, and set up with the procedures from 9.3.8 to 9.3.10.
9.3.11 Quitting procedure Click [Close] button to quit the application.
9.3.12 Closing procedure of new setting Close by the following procedure in the new setup (when the new module is added). 1) Jumper setting Open the short-circuited jumper (W1) at 9.3.1. 2) Baud rate setup of the DAU Use the Setup function (See 6.6) of the DAU and change the communication rate of the A/D connection CH (CH15 or CH16) to 19200bps.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
74 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
10. Trouble shooting and Utility
10. Troubleshooting and Utility How to use the utility function with the currently prepared maintenance software based on the following example. No.
Items
Function
Clause
1
When you want to perform an operation of the Internal Operation Panel of the
Control (R)
10.1.2
RCU by RIMOTO from the Maintenance PC
-- Control (R)
Pressing ACK button downward when alarm is ringed etc. 2
When you want to restart the RCU and DAU.
Control (R)
It can be restarted by remote control from maintenance PC. 3
When you want to search for the program version.
10.1.3
-- Control (R) Setup (C)
·
RCU:
”MCB-Application”, ”ARB”, ”FGB”
-- RCU (C)
5.4
·
DAU:
”DCB-Application”
-- DAU (D)
6.4
·
RCU:
”MCB-Boot”, ”MCB-Application”
·
DAU:
”DCB-Boot”, ”DCB-Application”
·
Maintenance software
Control (R)
10.1.4
-- Control (R) Help (H)
10.7
-- Version (A) 4
When you want to set the present time same as the VDR system. (The time is set automatically if GPS is connected)
5
When you want to initialize the system data of the RCU and DAU.
Control (R)
10.1.6
-- Control (R) Control (R)
10.1.8
-- Control (R) 6
When you want to research the reason why the RCU and DAU are restarted by the WDT (Watch Dog Timer).
Control (R)
10.1.10
-- Control (R)
A WDT generating factor code can be found. The number of times of WDT generated in the past can be found.
System (S)
10.3
-- System Log (L) 7
When the program upgrading has failed and the RCU and DAU normal operation is not working.
8
Control (R)
10.1.9
-- Control (R)
When you want to investigate the cause in which the VDR system has generated a fault.
System (S)
10.4
-- Event Log (E)
Refer to the past event log file. TXT and the CSV file will save the referred event. Excel etc will reference the saving file. The event file references the receiving file by the saving the file of PC card or the following function. Preparing the function to receive the past event file via LAN.
Control (R)
10.1.12
-- Control (R) 9
When you want to investigate the details of the error generated in the VDR. The error factor can be checked remotely by the Maintenance PC, without
System (S)
10.2
-- System Status (S)
seeing the Internal Operation Panel of the RCU. 10
When you want to reference the contents of the NMEA sentence data recorded by the VDR via the text editor or Excel.
11
The setting file of the RCU and DAU can be received and saved. The setting file of the RCU, FGB and DAU can be extracted and saved from the system configuration information file saved on the PC card. The setting file of the RCU, FGB, and DAU which are recorded on the capsule can be received and saved.
Japan Radio Co., Ltd.
10.6
-- Log to TXT (T)
When you want the setting file of the RCU and DAU.
Doc No.: H-7ZPJD0370
Data (D) Setup (C) -- RCU (C)
9.3
-- DAU (D)
10.3
Data (D)
Control (R) -- Control (R)
75 / 100
Maintenance Software Manual.doc
10.5
-- Config (C) 10.1.5
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
10.1
10. Trouble shooting and Utility
Control function - Control (R) -
How to remote control the VDR from the maintenance PC.
10.1.1 Startup Procedures Select [Control] from the Control menu.
The Control Window appears.
10.1.2
10.1.3
10.1.4
10.1.5
10.1.6
10.1.7
10.1.8 10.1.9 10.1.10
10.1.11
10.1.12
10.1.2 Remote control The operations that can be done from the RCU can also be done from the maintenance PC. • To stop recording • To restart recording • To set Alarm ACK These operations can be done from the maintenance PC. The other operations are not recommended. Button
Function
RESTART
To restart recording
STOP
To stop recording
• To compulsively reset initial error
BACKUP
To eject PC card
FUNC
To display the program version information by LED
ACK
To set the alarm ACK
FUNC + RESTART
To compulsively reset the initial error
FUNC + BACKUP
To backup the data in the Capsule to the PC card
FUNC + STOP
To immediately stop the backup operation
10.1.3 Rebooting the system The RCU and DAU can be rebooted by remote control. Click the RCU, DAU1 or DAU2 button.
10.1.4 Requesting program version The program version of the RCU or DAU can be displayed by remote control.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
76 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
10. Trouble shooting and Utility
Click the RCU, DAU1 or DAU2 button.
10.1.5 Downloading system configuration data from the HVR The system configuration information can be downloaded from the HVR and uploaded to any unit. 1)
Download Click the [Download] button, and the downloading of the data begins.
2)
Save the file Click the button of the unit to which you wish to save the file. In exchanging by PCB failure, it moves setting data by the following priorities. Therefore, this function is the last method. 1. Exchanging the EEPROM (MCB and DCB) 2. From the attached FD (Since newest nature may not be held, it does not recommend.) 3. From PC card data (See 10.5) 4. From the HVR ← (This function) A capture setting file can be obtained using the FGB button. Refer to "9.1", in uploading to FGB.
10.1.6 Real-time clock setup The date and time to the real time clock IC of the RCU or DAU can be checked and set up. 10.1.6.1 Selecting the unit Click the button of the unit. 10.1.6.2 Displaying the time & date Click the [Download] button, and the time & date are displayed. 10.1.6.3 Setting the time & date 1) Enter the time & date in the registration field. 2) Click the [Upload] button. 3) Reboot the selected unit with the “Reboot” function (see 10.1.3). 4) When the unit is rebooted, the entered time & date is registered. The time & date of DAU is supposed to be corrected on the ZDA sentence base. Use this function when time correction at the minute unit is needed before GPS is connected to DAU.
10.1.7 Renewing the system configuration data of the HVR The system configuration information is recorded in the RCU or DAU and can be uploaded to the HVR. Click the button of the unit you wish to download the file from.
It is not normally used. The setting data of the RCU and DAU are uploaded if the [Reboot] button is operated in the setup of system configuration information of the RCU and DAU as described in the paragraph 5.6. A reboot of the RCU and DAU should generate "an Initial error", without operating the [Reboot] button. In this case, cancel the error by the [FUNC+RESTART] operation described in paragraph 10.1.2. (Button operation of the internal operation panel of the RCU is also possible.)
10.1.8 Initializing system configuration data (EEPROM) The system configuration recorded in the EEPROM of the RCU or DAU can be changed to the default value. Click the button of the unit of the EEPROM you wish to initialize.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
77 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
10. Trouble shooting and Utility
Restarting starts operation by default setup. Keep in mind that the operation by the setup before the initialization is continued until it restarts.
10.1.9 Requesting operation mode and function status The operation mode and function status of the RCU or DAU can be displayed. Click the button of the unit for which operation mode and function status you wish to display. z MODE: • Application • Safe z FUNCTION: • Operation • Download Usually, “MODE=Application FUNCTION=Operation” is displayed. It will not operate correctly in any other situation. Ask the factory in this case. This operation can be fixed as "Operation", when the upgrading of the program has failed and does not operate as “FUNCTION=Download” when displayed.
10.1.10 Download abort log The RCU and DAU reboot itself when it gets out of control. This is enabled by the Soft WDT function. The abort log, which contains the reason why the program is aborted, can be downloaded. Click the button of the unit whose abort log you wish to download. The time & date of reset and the cause of the abort code are displayed. •
The following codes indicate normal operation. “Reboot command” “Version up start” “Version up end”
If a HEX code of 8 digits is displayed, contact the technical support division of JRC.
10.1.11 FGB maintenance mode The FGB maintenance mode can be started and closed by remote control. While VDR is in operation, the MCB is sending a command to the FGB to capture the image. This function needs to be shut down during the maintenance of the FGB. For this purpose, the MCB cuts itself away from the FGB in order to make the FGB free from interference. This is called the FGB maintenance mode. Once the FGB is set in the maintenance mode, the FGB error is displayed on the internal operation panel of the RCU.
10.1.12 Event Log file The event history file saved in the RCU is downloaded via a LAN circuit. The dialog is displayed if the [Receive] button is clicked. Then select the folder to save. The downloaded event file is the same as the file saved on the PC card. The method of getting the event history file can be selected from the following. • Downloading from the LAN connection (This operation) • Copy from PC card Refer to the operation of the “Event Log” (paragraph 10.4) when the downloaded event file is opened.
10.1.13 Quitting Click the [×] button in the upper right corner of the window.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
78 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
10.2
System Satus display
10. Trouble shooting and Utility
- System status (S) -
The operating status and the error detail information are displayed. The error display of the internal operation panel of RCU displays the error as a representation of each factor. Check the error detail information from the system status display.
When the alarm buzzer of the VDR is sounded, the error factor can be checked without looking at the internal operation panel of RCU. Seeing the system status display In the item which shows “OK/NG”, the result is shown by the red/green lamp. Pay attention the item as which the red lamp is displayed.
► CAUTION ◄ There are only OK and NG because the system status display has 1 Bit. In the case of NG, it is accepted as NG. It cannot necessarily be accepted as normal operation when OK is displayed. Example)
DAU: The CH which is not connected to the sensor equipment is also displayed as OK. Microphone test at the time of starting: OK is displayed even before testing the microphone.
10.2.1 Starting procedure Click the ”System status (S) “ from System (S) menu.
Window of the system status display is displayed. ● RCU system status window display: See para. 10.2.4. ● DAU system status window display: See para. 10.2.5.
10.2.2 Selecting the object unit Click the tab of the unit to check the system status. 10.2.3 Acquisition of the system status data Download the system status data from the desired unit. 1) Receive If [Receive] button is clicked, the data is received and the newest system status is displayed. 2)
Cyclical Receive Click of the [Cyclical Receive] button, system status data is received every 5 seconds. → The newest system status is updated periodically. The [Cyclical Receive] button changes to the [Stop] button during cyclical receiving. Click [Stop] button when stopping cyclical receiving.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
79 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
10. Trouble shooting and Utility
10.2.4 RCU System Status
10.2.4.1
10.2.3 [Receive] [Cyclical Receive]
10.2.4.2
10.2.4.3
10.2.4.4 10.2.4.6 10.2.4.5
10.2.4.7
10.2.4.8
10.2.4.9
10.2.4.11
10.2.4.10
10.2.4.12
10.2.4.1 Initial ”Initial” error is displayed. 1) Factor The RCU compares each system configuration information on the RCU and the HVR when RCU is started. If the system configuration information is not in agreement, it is detected as an initial error. → It is checking that the system configuration information in the HVR is recorded correctly. 2)
Correspondence Perform the operation as ”FUNC + Restart” by Remote Control function or from internal operation panel.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
80 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
10. Trouble shooting and Utility
10.2.4.2 Microphone test The detail of the ”MIC error” is displayed. ● Display of MIC number in which the error is detected. ● MIC error detecting timing. (After starting / When using ) The result of a microphone test is classified by "Start up" and "Running." • “Start up”: When the MIC error occurs by the microphone test immediately after RCU starting. • “Running”: When the MIC error occurs by the microphone test of every 12 hours. About the time of the microphone test for each Microphone • The MIC test is performed on each microphone for a maximum of 3 minutes. • When no problem can be found, the MIC test is performed for about 10 seconds per microphone. → Depending on a surrounding noise level, it might take about 3 minutes to determine. When the MIC test of 9 microphones is completed, it will be a waiting for a maximum of 30 minutes. Check the result of a microphone test using the real-time event monitor.
1)
2)
Factor The VDR outputs the test tone from the speaker with the built-in microphone in the cycle of 12 hours or at the time of starting and checking the input signal of the microphone. The MIC error is determined when input signal is out of standard. Correspondence A microphone unit is out of order. → The connection of the microphone might need to be changed . • Fault wiring → Check the wiring. • Fault setting → Check that the microphone unit is connected to all the enable microphone CH. • Surround noise → Restart the RCU after the background noise becomes low. •
- Reference Specifying the operation of a microphone test ● Microphone test timing • When starting • The cycles of 12 hours from starting • The microphone test is performed every 1 hour from the time of error generating only error CH. ( After results of MIC test become to normal, MIC test is performed as same timing as other MIC. ) ● Record operation condition Audio data is recorded from microphone unit even if MIC error occurs. (No-sound may be recorded when the microphone unit is out of order)
10.2.4.3 DAU The detail factor of ”DAU” error is displayed. No.
Items
Factor
Correspondence
1
Ethernet connection alarm
Ethernet connection is cut.
Check wiring. Check power supply. Check IP address.
2
DAU system alarm
The inside error of DAU
Check the system status display of DAU.
3
DAU data alarm
NMEA Sentence is not receiving normally in
Check the object CH from system status
some CH of DAU.
display of DAU.
10.2.4.4 Battery The state of a blackout signal is displayed. Green lamp: Normal Red lamp: Blackout
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
81 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
10. Trouble shooting and Utility
10.2.4.5 FAN Failure of FAN in the power supply unit is displayed. 1) Factor Either one or both of the fans in the power unit is out of order. 2)
Correspondence Replace both fans.
10.2.4.6 Capsule The detail factor of ”Capsule” error is displayed. ● Ethernet When the Ethernet connection cannot be connected with the HVR. ● Write connection error When the connection of the Write socket for each partition cannot be connected. ● Status connection error When reading the value of the BER from the object partition has failed. Correspondence
No.
Items
Factor
1
Ethernet connection error
Ethernet connection is cut.
Check the power supply of the capsule and LAN wiring.
2
Write connection error
Ethernet connection error is displayed for all
Check the partition setup of the HVR.
connections. 3
Status connection error
When only some partitions are error, a partition setup failed.
10.2.4.7 BER The detail status of the “BER” error is displayed. ● Result of the BER check for each partition ● BER count value of each partition 1) Factor HVR is out of order. The temporary failure due to very excessive temperature condition. 2)
Correspondence In order to check whether a condition changes or not, wait for several days. If the BER error is canceled automatically, the error occurred temporarily and is not important. If the error continues, consult with a Mitaka plant on a solution. - Reference About BER The HVR records the data in the built-in F-ROM. The recording procedure for this F-ROM is performed as follows: Write → Read → Verify It counts the number of Verify error as BER.
10.2.4.8 Mode The operation mode of RCU is displayed. No.
Items
1
RCU online
Mode 0: 1:
Offline Online
2
Booting with recovered configuration data
0: 1:
Normal Data recovered from FLASH ROM
3
Booting with default configuration data
4
Blackout
0: 1: 0: 1:
Normal Default configuration Normal Blackout
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
82 / 100
Maintenance Software Manual.doc
10. Trouble shooting and Utility
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual 5
Recording mode
0: 1:
Recording Recording stop
6
Data backup from HVR to PC card
0: 1:
Stop Backup
7
PC card loaded
0: 1:
Not loaded Loaded
8
Disc Opened / Disc Closed of the PC card
0: 1:
Disc closed Disc opened
9
Selecting GPS
0: 1:
Main GPS Sub GPS
10
Selecting Radar
0: 1:
Main Radar Sub Radar
10.2.4.9 PC card The detail factor of “PC card” error is displayed. No.
Items
Factor
Correspondence
1
Opening failure of PC card
PC card fault
Format the PC card Exchange the PC card when not
2
Detection failure of PC card
3
Un-loading of PC Card for 10 minutes
It take over 10 minutes without PC card.
Load the PC card.
4
File operation failure of PC card
PC card fault
Format the PC card Exchange the PC card when not
5
Folder operation failure of PC card
6
File search failure of PC card
7
File check failure of PC card
8
Reserve
9
Reserve
10
Opening disc failure of PC card
11
Closing disc failure of PC card
12
Formatting failure of PC card
being recovered by formatting.
being recovered by formatting.
10.2.4.10 MCB control The detail factor of ”MCB” error is displayed. No.
Items
1
Time-out of initialization
Initialization processing of MCB was not completed to within a time.
Factor
2
Initialization failure of Nucleus NET
Abnormal Ethernet driver
3
Reading failure from external RTC
The RTC fault of the built-in MCB
4
Receiving failure of time correction data
Abnormal Ethernet driver
5
Initialization failure of Nucleus File
Abnormal File driver
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
83 / 100
Maintenance Software Manual.doc
Correspondence Restart and check whether there is any other error factor. Exchange MCB, when other errors do not occur. Restart. Exchange MCB if restarting did not work.
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual 6
EEPROM checksum error MAC address
10. Trouble shooting and Utility
Abnormal checksum value of EEPROM
Reset the data.
EEPROM fault
Exchange EEPROM.
LAN information IEC61996 System information 7
EEPROM reading error
8
EEPROM writing error
9
FLASH ROM checksum error MAC address
Abnormal checksum of system setup which is saved in F-ROM for back up
Setup the data.
LAN information IEC61996 System information FLASH ROM writing error
F-ROM fault
Exchange the MCB.
10
10.2.4.11 ARB control The detail factor of “ARB” error is displayed. No.
Items
Factor
Correspondence
1
Error response from ARB
ARB fault
Exchange ARB.
2
Time-out of Initialization
3
No response to microphone test
4
No received audio data
5
No received audio header data
10.2.4.12 FGB control The detail factor of “FGB” error is displayed. No.
Items
1
PING no response
Ethernet disconnection
Factor
2
Ethernet disconnection
3
Maintenance mode
The error of IP address setup FGB fault HUB fault During maintenance mode
4
No configuration data
The configuration data is not set to FGB.
5
Switching failure to the Radar unit
6
No RGB signals from Radar
In two radar connections, the each configuration data is not set up, or the radar is not connected. RGB signal is not detected.
7
Receiving failure of image data
Receiving failure of image data.
8
No response to a command
The no response error to a command.
9
Sleep mode by blackout
The sleep mode by blackout.
Return on the power.
10
Real time monitor request error
The UDP transmission IP address to FGB has not been set up.
Set up the IP address of Transmission.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
84 / 100
Maintenance Software Manual.doc
Correspondence Connect the LAN connection Restart RCU Set up IP address Exchange FGB. Exchange HUB. Close the maintenance mode by the Control operation. Set up the configuration data to FGB. Set up the each configuration data. Connect the radar. Check the wiring with radar. Check whether image data can be received in a browser (IE). Exchange FGB, if you cannot receive, even if it restarts.
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
10. Trouble shooting and Utility
10.2.5 DAU system status
10.2.5.1
10.2.5.2
10.2.5.3
10.2.5.4
10.2.5.1 NET ”NET” error is displayed. 1) Factor The DAU cannot be connected with RCU via Ethernet. 2)
Correspondence • Check the wiring • Check the power supply of RCU and DAU • Check the IP address setup
10.2.5.2 Serial Port The receiving state of each serial CH (16CH in total) is displayed. ● NMEA sentence receiving error for each CH ● Setup state of DIP-SW for each CH. 1)
Factor • The sensor equipment fault • The wiring fault between sensor equipment • The setup fault
2)
Correspondence • Check the signal output from the sensor equipment. • Check the wiring. • Check the setup (filter setup, receiving interval setup etc.) DIP-SW • ON: Check the receiving error. • OFF: No check the receiving error. When the sensor equipment does not output the sentence periodically, turn off the object CH of DIP-SW on PCB (DCB) of the DAU. Receiving error of the CH is not checked by the DAU.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
85 / 100
Maintenance Software Manual.doc
10. Trouble shooting and Utility
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
10.2.5.3 Mode The operation mode of DAU is displayed. No.
Items
Mode
1
DAU online
0: 1:
Offline Online
2
Booting with recovered configuration data
3
Booting with default configuration data
0: 1: 0: 1:
Normal Data recovered from FLASH ROM Normal Default configuration
10.2.5.4 DCB control The detail factor of ”SYSTEM” error is displayed. No.
Items
1
Time-out of initialization
Initialization processing of DCB was not completed to within the time.
Factor
Correspondence
2
Initialization failure of Nucleus NET
Abnormal Ethernet driver
3
Reading failure from external RTC
The RTC fault with built-in DCB
4
Receiving failure of time correction data
Abnormal Ethernet driver
5
EEPROM checksum error MAC address
Abnormal EEPROM
checksum
value
of
Restart and check whether there is any other error factor. Exchange DCB, when other errors do not occur. Restart. Exchange DCB if it is not recovered by restarting.
Reset up the data.
LAN information IEC61996 CH01-- CH16 System information 6
EEPROM reading error
7
EEPROM writing error
8
FLASH ROM checksum error MAC address LAN information
EEPROM fault
Exchange EEPROM.
Abnormal checksum of the system setup which is saved in F-ROM for backup.
Reset up the data.
Abnormal F-ROM
Exchange DCB.
IEC61996 CH01-- CH16 System information 9
FLASH ROM writing error
10.2.6 Quitting procedure Click [×] button on the upper right of the Window.
10.3
System Log display
- System Log (L) -
Confirm the counter value of WDT (self –reset by abort ) on RCU and DAU. Confirm the counter value of WDT at installation and maintenance on the board. Contact the factory when RCU or DAU counted.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
86 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
10. Trouble shooting and Utility
10.3.1 Starting procedure Click ”System Log (L)” of System (S) menu.
The “System Log” Window appears.
“Tab” [Receive] [Clear]
10.3.2 Receiving of system log data The system log data of RCU or DAU can be displayed. 1) Selecting the object unit Click the tab of the unit to be checked in the system log. 2) Receiving data Click the [RECEIVE] button, and the counter value of WDT is displayed.
10.3.3 Clearing of system log data The counter value of WDT can be cleared. 1) Selecting the object unit Click the tab of the unit to be checked in the system log. 2)
Clearing the counter value of WDT Click the [Clear] button, and the counter value of WDT is cleared.
10.3.4 Quitting procedure Click [×] button on the upper right of the Window.
10.4
Event Log display
- Event Log (E) -
Check the past event log on the PC card of the RCU. RCU can save a maximum of 10240 event data by loop recording.
10.4.1 Starting procedure Click ”Event Log (L)” of System (S) menu.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
87 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
10. Trouble shooting and Utility
Event log application software starts.
10.4.2 Getting of event log files Get event files by one of the following procedure. 10.4.2.1 Downloading from the RCU The event log files can be downloaded by using the following function. ”10.1.12 Event Log file” (“Control”) 10.4.2.2 Reading from the PC card of the RCU 1) Ejecting the PC card from RCU Click the [BACKUP STOP] button on the internal operation panel of the RCU and then the PC card can be ejected. 2)
Setting the PC card Set the PC card to a PCMCIA slot in a lap top PC for maintenance.
10.4.3 Display the event log data Open the getting event log files and display the event log data 1) Opening the dialog Click “Open (O)” of “file” menu. 2)
Selecting the file Select the “writefile.txt” at the dialog and open it. “writefile.txt” · Downloading from RCU: It is saved in the selected folder. · PC card: It is saved in the “event” folder of the PC card.
3) Event log data The event code saved at the file is changed to character and displayed.
10.4.4 Functions of event log application 1) Sorting Past event log data can be displayed and sorted. Click the head title of target column and it will be displayed and sorted by the contents of the column. 2) Saving a file Past event log data can be saved at a “txt” or “CSV” type file. Click “Save (S)” of “file” menu.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
88 / 100
Maintenance Software Manual.doc
10. Trouble shooting and Utility
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual You can open a file with text editor or Excel.
10.4.5 Changing of display language A display language of Event can be changed to Japanese. 1) Selection of display language Click “Language” in the “View” menu, and then choose from English and Japanese.
10.4.6 Quitting procedure Click [×] button on the upper right of the Window.
10.5
System Configuration file in the PC card
- Config (C) -
The setup file for each unit can be created from a system configuration file.
10.5.1 Starting procedure Click ”Config (C)” of “Data (D)” menu.
The “Config” Window appears.
10.5.2
10.5.3 10.5.4 10.5.5
10.5.2 Selecting a file Select a system configuration file. 1)
Selecting the file Click the [Open file] button and then select a system configuration file at the dialog. The system configuration file to open must be chosen according to the target units. Refer to the following table.
Target unit
File
Folder
RCU、DAU1、DAU2、FGB1、FGB2
SysInfo.dat
DSC1、DSC2、DSC3、DSC4
Option.dat
• “Init” folder of the PC card • “Init” folder in the saved folder at backup from the Capsule • “Option” folder in the saved folder at backup from the Capsule
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
89 / 100
Maintenance Software Manual.doc
10. Trouble shooting and Utility
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
10.5.3 Saving a setup file Select a saving file to setup target data. 1) Selecting a button Click the button for target data and then the dialog of saving a file is displayed. Input a file name and save it. Only effective buttons can be displayed.
In exchanging by PCB failure, it moves setting data by the following priorities. Therefore, this function is the last method. · Exchanging the EEPROM (MCB and DCB) · From the attached FD (Since newest nature may not be held, it does not recommend.) · From PC card data ← (This function) · From the HVR (See 10.1.5)
10.5.6 Quitting procedure Click [×] button on the upper right of the Window.
10.6
Converting “Log” to text
- Log to TXT (T) -
The “Log” files of NMEA sentence can be converted into a text file.
10.6.1 Starting procedure Click ”Log to TXT (T)” of “Data (D)” menu.
The “Log to TXT” Window appears.
10.6.2 10.6.3 10.6.4
10.6.2 Selecting a “Log” folder Select a “Log” folder which is root folder of saved log files in the PC card. 1) Selecting a folder Click the [Browse] button of “Load folder” and then select a “Log” folder in the PC card.
10.6.3 Selecting a “text” file Select a folder to save a text file. 1) Selecting a folder Click the [Browse] button of “Save folder” and then select a folder in a lap top PC for maintenance.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
90 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
10. Trouble shooting and Utility
10.6.4 Starting to convert Click the [Convert] button and then conversion is started. Progress of converting is displayed by Progress bar. The converted text file is saved by making "recording start time" into a file name at a selected folder. Sample:
200401201030.txt
(10:30 on January 20, 2004)
10.6.5 Quitting procedure Click the [Close] button.
10.7
Program version of Maintenance Software
- Version (A) -
The program version of maintenance software can be displayed.
10.7.1 Starting procedure Click ”Version (A)” of “Help (H)” menu.
The “Version” Window appears.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
91 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
BLANK PAGE
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
92 / 100
Maintenance Software Manual.doc
10. Trouble shooting and Utility
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
11. Program Upgrade
11. Program Upgrade How to upgrade the version of following program which constitutes VDR, is explained Upload the newest program file from the maintenance PC via LAN. ●
Composition of F-ROM which saves the program Unit
PCB
Existence of F-ROM
Program
Clause
RCU
MCB (CDJ-2142)
Exists
RCU_Boot
11.1
RCU_Application ARB_Application ARB (CHA-372)
Not exist
Downloading from MCB
-
FGB (CKA-129)
Exists
FGB_Boot
11.2
FGB_Application DAU
DCB (CDJ-2143)
Exists
DAU_Boot
11.1
DAU_Application
* The application program of ARB operates by downloading the program from ROM of MCB.
11.1
Program Upgrade
- Version up (U) -
Upgrade the program of RCU (MCB, ARB) and DAU (DCB).
11.1.1 Starting procedure Click ”Version up (U) “ in “Version up (U)” menu.
The program upgrade application starts.
11.1.2 11.1.3 11.1.4
11.1.2 Selecting the unit Select the type of the software and the unit set as the object of upgrade from the RCU, DAU1, and DAU2. Click the selection button.
11.1.3 Program file Select the program file to upgrade. Click [Browse] button to select the upgrade file.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
93 / 100
Maintenance Software Manual.doc
11. Program Upgrade
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
Do not mistake, that a file type is “ *.Jrc ”. ► Caution ◄ Do not make the set file type and the upgrade file contradicting. The operation is stopped, if upgrade which was wrong as follows is performed. Example) The application of RCU has been uploaded into DAU.
11.1.4 Communication circuit setup Select the communication circuit to set up. Click the selection button of either ”LAN” or ”COM”. “COM” is supported in this function. However, it is not necessary to use it.
11.1.4.1 LAN Destination IP address and the port number are needed to set up when LAN is selected. However, it is not necessary to change because it is set up automatically by selecting the unit of 11.1.2. It is necessary to set up only when IP address of RCU and DAU is changed from the default value by the option system.
11.1.4.2 COM If COM is selected, COM number which is used in the maintenance PC need to be inputted.
11.1.5 Starting the upload Click [Update] button to start the program upload. Upload situation is displayed by progress bar or the message.
11.1.5 “Progress bar” “ Progress message” Upgrading
Upgrading complete
11.1.6 Completing upload Check that upload is complete. ● Check that progress bar is complete till the end. ● Check that ”[END]Update Success” is displayed in the progress message. The object unit is restarted automatically and start operation with upgrade program after the upload is complete. It is not necessary to reset up the system composition information by upgrade. If the upgrade to need occurs, it tells about by technical information.
11.1.7 Quitting procedure Click [×] button on the upper right of the Window.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
94 / 100
Maintenance Software Manual.doc
11. Program Upgrade
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
11.2
FGB Program Upgrade
- FGB
(F) -
How to upgrade the program of FGB (RCU) is explained.
11.2.1 FGB upgrade mode (Hard) setting The setup switch on the FGB (PCB) need to be changed when upgrade the program. Change the setup switch (S2) which is on PCB as following. S2-1 ON
S2-2 ON
S2-3 OFF
S2-4 OFF
S2-5 OFF
S2-6 ON
S2-7 OFF
S2-8 ON
FGB (CKA-129) 部品面 Side of parts S2 1 OFF
ON
8
11.2.2 Disconnecting the LAN cable of MCB (CDJ-2142 ) Disconnect the LAN cable of the MCB which be installed right side of operation panel.
11.2.3 Starting Click ”FGB (F) “ from “Version up (V)” menu.
The program upgrade application starts.
11.2.4 11.2.5
11.2.6
11.2.4 Program file Select the program file to upgrade. Click [Browse] button to select the upgrade file. Do not mistake, that file type is “ *.Txt ”. There are two different kinds of the program file as ”Application” and ”Boot”. The detail information about file to upgrade or etc. is told by technical information.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
95 / 100
Maintenance Software Manual.doc
11. Program Upgrade
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
11.2.5 Communication circuit setup There is the item for setting up the Destination IP address and port number, however it is not necessary on usual. It is necessary to set up only when IP address of the FGB is changed from the default value by the option system.
11.2.6 Starting upload Click [Execute] button to start the program upload.
11.2.7 Completing upload Check that uploading is complete. ● Check that ”Application write OK” is displayed in the message display column.
11.2.8 Quitting procedure Click [×] button on the upper right of the Window.
11.2.9 FGB usual mode (hard) setup Reset the switch setup which was changed to upgrade mode. Reset the switches on the PCB using the following setup. S2-1 ON
S2-2 OFF
S2-3 OFF
S2-4 OFF
S2-5 OFF
S2-6 OFF
S2-7 OFF
Return the switch. The otherwise, it does not start.
11.2.10 Connecting the LAN cable of MCB (CDJ-2142 ) Connect the LAN cable of the MCB which be installed right side of operation panel.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
96 / 100
Maintenance Software Manual.doc
S2-8 OFF
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
12.
Installation
12. Installation of Maintenance Software Installation procedure of maintenance software for JCY-1700
12.1
Selection of languages
Two language versions are supported Japanese and English. 1) CD for installation Perform “setup.exe” saved in “Japanese” folder if installing the Japanese OS. Perform “setup.exe” saved in “English” folder if installing the English OS. 2)
The difference between the Japanese version and the English version • The message language of the installer becomes Japanese/English. • The event message of EVENT function becomes Japanese/English. → Object function: ”EVENT Log”, ”EVENT Monitor” All display languages other than the above are English notations.
12.2
Installation procedure
There are two types of the JCY-1700 maintenance software installer. Carefully perform installation according to the following procedure. When the old version of the maintenance software has previously been installed, uninstall and perform the setup. 12.3.
1) Performing “setup.exe” Double-click ”setup.exe” file. 2) Starting installer When [Next >] button appears, click it after displaying the following window.
3) User information Input “jrcvdr” into the serial number block and click [Next >] button. (Installation can be completed without inputting the user name and the organization.)
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
97 / 100
Maintenance Software Manual.doc
Refer to
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
4)
Specifying of the installation folder “Program Files¥JRC¥JCY1700¥Maintenance” is specified as the default installation folder. Click [Next >] button.
5) Starting installation Click [Install ] button to start the installation.
Click [Finish] button.
6) Starting the next installer When the second installer starts, click [Next >] button.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
98 / 100
Maintenance Software Manual.doc
12.
Installation
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
12.
Installation
7) Specifying the installation folder “Program Files¥JRC¥JCY1700¥Maintenance¥Event_monitor” is specified as the default installation folder. Click [Next >] button.
8) Starting installation Click [Next >] button to start the installation.
Click [Close] button.
9) Completing installation The shortcut for the “Maintenance Software” of the JCY-1700 will be placed on the desktop. Double-click it to start.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
99 / 100
Maintenance Software Manual.doc
JCY-1700 VOYAGE DATA RECORDER / Maintenance Software Manual
12.3
12.
Installation
Upgrade
Procedure for upgrading the maintenance software. If the old version is installed, install after deleting the following application from the ”Control Panel” - ”Add/remove Programs” of Windows. • < JCY-1700 Maintenance Ver x.x.x > • < JCY-1700 Event monitor > * If the installation is performed without deleting, the message which directs deletion is displayed.
Japan Radio Co., Ltd. Doc No.: H-7ZPJD0370
100 / 100
Maintenance Software Manual.doc